TLE Series UPS 160/200/225/250 kw with eboost Technology

Similar documents
TLE Series UPS 400/500 kw With eboost Technology

TLE Series UPS 750/1000 kw With eboost Technology

Technical Data Sheets

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

Technical Data Sheets

Technical Data Sheets

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

Technical Data Sheets

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

Technical Data Sheets

Technical Data Sheets

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

Technical Data Sheet. Uninterruptible Power Supply. Digital Energy. imagination at work

gimagination at work Technical data sheet Uninterruptible Power Supply LP Series 6 & 10 kva GE Digital Energy

Technical Data Sheets

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

Technical Data Sheets

Technical data sheets

EFFEKTA Power Supplies

Technical data sheet VH UL. Digital Energy Uninterruptible Power Supply. GE Digital Energy Power Quality

Eaton 93PS 8-40kW UPS Technical Specification Manufacturer s declaration in accordance with IEC

PowerValue 11/31 T kva

TECHNICAL DATA SHEET KVA UPS Systemss

SmartOnline SUT Series 3-Phase 208/120V 220/127V 30kVA 30kW On-Line Double- Conversion UPS, Tower, Extended Run, SNMP Option

SmartOnline SUT Series 3-Phase 208/120V 220/127V 20kVA 20kW On-Line Double- Conversion UPS, Tower, Extended Run, SNMP Option

1.1 GENERAL CHARACTERISTICS

TECHNICAL DATA SHEET INFINITY kva 3Ph(in) 3Ph(out)

POWER kva

POWER kva Nominal output power (Cos φ0,8) kva Nominal output power (Cos φ1,0) kw >88 Efficiency (AC AC)

TECHNICAL DATA SHEET B8033FXS kva 3Ph(In) 3Ph(Out)

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

POWER kva

TECHNICAL DATA SHEET B8031 FXS kva 3Ph(In) 1Ph(Out)

PowerWave 33 Efficient power protection for today s IT and process-related work environments

Three Phase UPS Systems Range: 10 to 500kVA

DELPHYS GP. Green Power 2.0 range 160 to 1000 kva/kw

Technical data sheets

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

POWERTRONIX QUASAR 5-40 KVA

n Lower energy costs and carbon footprint n Cooler operation extends internal component life n High input power factor of 0.99

Series. On-line, Single-phase Parallel Redundant UPS System. 6 and 10 kva Rack Mount. Your Tailored Power Solutions Provider TM

PowerScale kva Technical Specifications

n Lower energy costs and carbon footprint n Cooler operation extends internal component life n High input power factor of 0.99

Power Lynx 3 Uninterruptible Power System (UPS) Technical Specifications

SmartOnline SUT Series 3-Phase 208/120V 220/127V 40kVA 40kW On-Line Double- Conversion UPS, Tower, Extended Run, SNMP Option

Fortress 3 Harsh. Harsh Environment. Emergency Central Lighting Inverter (CLI) Technical Specifications

G V Series UNINTERRUPTIBLE POWER SYSTEMS. Phone: Fax: Web:

Liebert. FP 50Z kva

Cobra 3 Stand-By Emergency Central Lighting Inverter (CLI) Technical Specifications

Series. Full Three Year Warranty. On-line, Single-phase Parallel Redundant UPS System. 6 and 10 kva Tower. Your Tailored Power Solutions Provider TM

PowerScale TECHNICAL SPECIFICATIONS

POWER+ PREMIUM CBS. BS-EN Emergency electrical installations Electric power systems Emergency lighting Escape lighting

Model ESV Uninterruptible Power System 1.5 KVA/KW KVA/KW Single Phase

un I Jet ИБП ABB Conceptpower DPA 500 ( квт) - технические спецификации. Юниджет

SmartOnline SVTX Series 3-Phase 380/400/415V 20kVA 18kW On-Line Double-Conversion UPS, Tower, Extended Run, SNMP Option

Fortress 1 Outdoor Emergency Central Lighting Inverter (CLI) Technical Specifications

Liebert Hipulse E The High-ECO-Availability UPS. AC Power Systems

MKN-DSP SERIES - THREE PHASE

D Series: UPS UPTO - 300KVA - Three / Three Phase

Defender Mini Online Emergency Central Lighting Inverter (CLI) Technical Specifications

UPS Sentry HPS. power supply sources - isolation transformers and generators over less sophisticated power systems.

ConceptpowerTM Modular kVA

Illuminator Series CR NEMA 3R

Marketing Management Team of Europe

MASTERYS IP+ 10 to 80 kva

G9000 UNINTERRUPTIBLE POWER SYSTEMS

SitePro UPS 400Vac / CE. GE Consumer & Industrial August 2004

Green Power 2.0 MASTERYS GP

10 20KVA 3Ph/1Ph KVA 3Ph / 3Ph

G9000 UNINTERRUPTIBLE POWER SYSTEMS

TOSHIBA /20/25/30/50kVA Internal Battery GUIDE SPECIFICATION THREE PHASE UNINTERRUPTIBLE POWER SUPPLY

Standalone three-phase UPS system. PowerWave kw Unmatched power performance

60 to 160 kva.

Master Plus kva

Product Specifications

Industrial PFC UPS System

KEOR HP. THREE-PHASE UPS from 100 to 800 kva GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

GUIDE SPECIFICATIONS 15-45kVA and 15-90kVA Scalable Three-Phase Uninterruptible Power System 1.0 GENERAL

LIEBERT APM 3-PHASE UPS: 15-90KVA/KW, 60HZ, VAC, SINGLE & DUAL INPUT - SITE PLANNING DATA

SmartOnline S3MX Series 3-Phase 380/400/415V 60kVA 54kW On-Line Double-Conversion UPS

Onfiniti. 1 Phase UPS

MODULAR THREE-PHASE AND SINGLE-PHASE UPS SYSTEM

Flywheel UPS Systems, kva

GUIDE SPECIFICATION THREE PHASE UNINTERRUPTIBLE POWER SUPPLY

KEOR HP. THREE-PHASE UPS from 100 to 800 kva GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

INDUSTRIAL PROCESSES TELECOM- MUNICATIONS DEVICES EMERGENCY DEVICES INDUSTRIAL

APC Smart-UPS. GUIDE SPECIFICATIONS FOR 1000VA & 2000VA Smart-UPS 230VAC Uninterruptible Power Supply

DPP/3DPP. Digital ProcessPower UPS INDUSTRIAL PWM UNINTERRUPTIBLE POWER SUPPLY SYSTEM SINGLE PHASE THREE PHASE

MGE TM Galaxy TM 7000 GFC

Illuminator Series CM. GUIDE SPECIFICATIONS And TECHNICAL DESCRIPTION. 500W, 1000W, 1500W and 2000W Single-Phase Emergency Power System

3. MAJOR SYSTEM COMPONENTS Emergency Lighting Power System shall consist of the following major subsystems:

Master MPS kva kva 3:1 3:3 VFI TYPE

Liebert APM UPS. For a 30 to 150 kva / kw (50 or 60Hz) Modular Digital Uninterruptible Power Supply (UPS) System. V nd February 2010

3 Uninterruptible Power Systems

Liebert GXT & 6000VA RT230 Rack-Tower models GUIDE SPECIFICATIONS 1.0 GENERAL

Smart-UPS VT APC Smart-UPS VT 30kVA 208V w/4 Batt. Modules, Start-Up 5X8, Internal Maintenance Bypass

TELECOM- MUNICATIONS DEVICES INDUSTRIAL EMERGENCY DEVICES. (Servers Farms, ISP/ASP/POP)

TELECOM- MUNICATIONS DEVICES INDUSTRIAL EMERGENCY DEVICES. (Servers Farms, ISP/ASP/POP)

EATON 9315 UPS 200 TO 300 KVA Specifications

Transcription:

TLE Series UPS 160/200/225/250 kw with eboost Technology The new TLE Series Uninterruptible Power Supply (UPS) is a three-phase high power product with best-in-class multi-mode efficiency for global critical power needs. The TLE platform establishes GE UPS technology leadership in high power applications with industry leading differentiation in efficiency, output power capacity and footprint. GE s TLE Series UPS is one of the most energy efficient multi-mode UPS in the industry, and provides world-class energy efficiency across the operating load range. The TLE Series delivers efficiency up to 97% in double conversion mode and 99% in eboost operating mode. This system efficiency substantially reduces operating and cooling costs thus providing a reduced cost of ownership and improved power usage effectiveness (PUE) compared to conventional UPS. Features and Benefits Key Applications/Verticals Multi-Mode Efficiency Superior Input, Output & Physical Characteristics Advanced User Interface UPS RPA Paralleling Architecture Technology at Its Best Highly reliable and efficient tri-level conversion Automatic or manual multi-mode operation Best of Both Worlds Operating Efficiency Up to 97% efficiency in premium protection mode (double conversion) Up to 99% efficiency in premium energy save mode (eboost) Electrical Environment Optimization Unity (1) Output Power Factor High (0.99) Input Power Factor Less than 5% Input Current Harmonic Distortion Technology at Its Best Highly reliable and efficient tri-level conversion Automatic or manual multi-mode operation Data Centers Healthcare Facilities Financial Institutions Colleges/Universities Reliability, Diagnostic & Monitoring Enhancements GE Capital Retrofit Program

GENERAL DATA Topology Nominal output power at PF = 1 System Efficiency in Double Conversion operating mode @1 PF load, nominal voltage/frequency, energy storage disconnected True double conversion (VFI) Transformerless 160kVA (160 kw) / 200kVA (200 kw) / 225kVA (225 kw) / 250kVA (250 kw) 25% load 50% load 75% load 100% load 160kW 94.2% 96.1% 96.4% 96.4% 200kW 95.0% 96.4% 96.6% 96.5% 225kW 95.5% 96.6% 96.6% 96.5% 250kW 95.8% 96.7% 96.5% 96.4% System Efficiency in eboost Operating mode @1 PF load, nominal voltage/frequency, energy storage disconnected 25% load 50% load 75% load 100% load 160kW 97.0% 98.0% 98.2% 98.2% 200kW 97.3% 98.3% 98.3% 98.5% 225kW 97.6% 98.6% 98.8% 98.8% 250kW 97.7% 98.7% 98.9% 98.9% Heat rejection in Double Conversion operating mode @1 PF load, nominal voltage/frequency, energy storage disconnected 25% load 50% load 75% load 100% load 160kW BTU/hr / kw 7893 / 2.3 10531 / 3.1 14665 / 4.3 19495 / 5.7 200kW BTU/hr / kw 8548 / 2.5 12125 / 3.6 17644 / 5.2 23959 / 7.0 225kW BTU/hr / kw 8593 / 2.5 13113 / 3.8 20023 / 5.9 27184 / 8.0 250kW BTU/hr / kw 9026 / 2.6 14118 / 4.1 22120 / 6.5 30461 / 8.9 Heat rejection in eboost operating mode @1 PF load, nominal voltage/frequency, energy storage disconnected 25% load 50% load 75% load 100% load 160kW BTU/hr / kw 4096 / 1.2 3461 / 1.6 7372 / 2.2 9829 / 2.9 200kW BTU/hr / kw 4608 / 1.4 5802 / 1.7 7675 / 2.3 10239 / 3.0 225kW BTU/hr / kw 4720 / 1.4 5450 / 1.6 6994 / 2.0 9325 / 2.7 250kW BTU/hr / kw 5020 / 1.5 5618 / 1.6 7116 / 2.1 9488 / 2.8 Max Cooling Air (77 F - 86 F / 25 C - 30 C) 160/200/225/250kVA) 1400/1600 CFM Audible noise level (at 5 ft./1.52mts) Double Conversion Mode eboost Mode Operating temperature range UPS Battery Storage temperature range UPS Battery (VRLA) Relative Humidity Maximum Altitude 75 db(a) 65 db(a) 32 F - 104 F (0 C - 40 C) 68 F - 77 F (20 C - 25 C) (Note: Higher temperatures shorten battery life) 5 F - 122 F (-15 C to +50 C) 32 F - 104 F (0 C - 40 C) Storage time is 3 months at 77 F (25 C) (Note: Higher temperatures shorten battery life) 0-95%, non-condensing ft (M) ft (M) 3281 / 1000 (no derating) 4921ft (1500Mts) 6562ft (2000Mts) 8202ft (2500Mts) 9843ft (2500Mts) Derating -2.5% -5.0% -7.5% -10.0% 2

TECHNICAL DATA SHEET - 160 / 200 / 225 / 250 kw UL LISTED Enclosure Type Indoor (IP20) and NEMA PE 1 Safety Cooling Internal dead front construction Forced Air Color Black (RAL 9005) Installation Rigging Mounting Installation and maintenance access Conduit Entry Standards Electrostatic discharge immunity Configuration Standard Optional Fault current rating Suitable for handling by forklift Floor mounting holes provided Front access required for normal maintenance Top and Bottom standard ETL Listed to UL 1778, ANSI C62.41b 4kV contact / 8kV air discharge Stand-alone Redundant Parallel Architecture (RPA) - up to 6 modules may be paralleled in any combination for redundancy or capacity UPS is designed for installation in an electrical system up to 65kA RECTIFIER Configuration Three phases rectifier bridge with three level IGBT technology Input Voltage 480VAC, 3-phase, 4 wire + ground OR 3 wire + ground (+/- 15% without battery discharge) Frequency 60Hz, +/-10% (54-66Hz) Harmonic Current Distortion <5% Power Factor (Typical) 0.99 lagging Inrush current Limited by soft-start circuit Power walk-in 30 seconds (Adjustable) Output Voltage Tolerance +/- 1% DC ripple voltage +/- 1% DC ripple current Max. 5% of battery capacity expressed in amps UPS RATING vs. CURRENT LIMITS 160 kva/kw 200 kva/kw 225 kva/kw 250 kva/kw Nominal input (100% load) Current[A]: 201.6 251.7 283.5 315.0 (1 PF load, fully chrg'd bat.) kva 167.6 209.3 235.7 261.9 kw 165.9 207.2 233.3 259.2 Maximum input (100% load) Current[A]: 228.9 279.0 310.2 341.7 (1 PF load, max. chrg current) kva 190.3 232.0 257.9 284.1 kw 188.4 229.7 255.3 281.2 Max. charge current A: 45 45 45 45 3

BATTERY Battery compatibility Number of cells Float voltage at 68 F (20 C) Minimum discharge voltage Recharge time Battery ground fault detection Automatic and manual battery test Common battery in parallel system Lead-acid or NiCd, VRLA or flooded 240 (lead-acid) 540VDC 396VDC (adjustable) 10 times the discharge time Standard Standard Up to 3 units UPS RATING 160 kva/kw 200 kva/kw 225 kva/kw 250 kva/kw @100% load, 1 PF kwb: 166.6 208.2 234.3 260.0 Maximum Discharge Current (1.65V cell) A: 421 526 592 658 INVERTER Nominal output voltage 480VAC, 3-phase, 4 wire + ground or 3 wire + ground Inverter bridge Three phases inverter bridge with three level IGBT technology IGBT Output waveform True sine wave Output voltage tolerance Static +/- 1% Load step 0% - 100% - 0% +/- 3%, recovering to within +/- 1% in 1 cycle Load step 0% - 50% - 0% +/-2%, recovering to within +/- 1% in 1 cycle 100% unbalanced load (Ph-N) +/- 3% Output voltage distortion 100% linear load 3% THD maximum 100% non-linear load (per IEC 62040) 5% THD maximum Crest factor capability < 3:1 Output neutral rating 200% Phase displacement 100% balanced load 120 +/- 1% 100% unbalanced load 120 +/- 2% Output frequency Free running 60Hz, +/- 0.1% Synchronized with utility +/- 4% (adjustable from 57.6Hz to 62.4Hz) Overload capability (on inverter) 125% at 1 PF for 1 minutes 150% at 1 PF for 30 seconds Short circuit capability (on inverter) 220% for 100 ms, electronically limited UPS RATING (kw) 160 kva/kw 200 kva/kw 250 kva/kw 250 kva/kw Maximum Output Current @ 1 PF A 192.5 240.6 270.6 300.7 4

STATIC BYPASS Input configuration Single input (standard) or dual input (optional) Primary components Fully rated continuous duty static switch Back feed protection + Semiconductor fuse for clearing fault currents Transfer limits +/- 10% of nominal output voltage (adjustable) Overload capability (on bypass) 110% continuous 150% for 1 minute Short circuit capability (on bypass) 1000% for 1/2 cycle (non-repetitive) eboost TM OPERATING MODE Input wiring configuration 480VAC, 3-phase, 4 wire + ground OR 3 wire + ground Output waveform Transfer time to Inverter Transfer limits Steady-state RMS tolerance Instantaneous voltage distortion (with respective to Normal Sine wave) Steady-state frequency tolerance Instantaneous phase shift Continuously monitored <2ms (typical) +/-20 Vrms (adjustable) Magnitude Duration +/-3 Hz 0.15 radians (8.5 Deg) +/-75Vp 500µs (adjustable) EXTERNAL INTERFACE Alarm contacts (voltage-free) Standard Optional Communication Input signals Diagnostics 6 user defined contacts (form C ) (1A / 24V DC) 12 user defined contacts (form C ) (1A / 24V DC) (23 selectable signals include aux. Inputs 1 & 2) RS-232 / SNMP / MODBUS Emergency Power Off (user supplied N.C. contact) Aux. input 1 * (default = On Generator) Aux. input 2 * (configurable) * Status displayed on LCD panel Internal Waveform Capture. Input and output w/pre and post event data (Field Service Only) 5

FRONT PANEL CONTROLS, SIGNALS & ALARMS Touch Screen Graphic Display Mimic Diagram Operation Alarm Warning LED Load Level / Battery Run Time Multilanguage Graphic LCD Represents operational status of the UPS on Home Page of LCD Visual indicator when load is on inverter OR load is on bypass BLINK during service check Visual indicator and audible signal, activates approx. 3 minutes (adjustable) before complete and automatic load shutdown due to the battery is fully discharged and the load cannot be transferred on utility or Over temperature or overload condition (>125%) and the load cannot be transferred on utility. Visual indicator and audible signal active when any alarm condition is present BLINK when alarm is active and not acknowledged Bar graph status indicator on Home Page of LCD Load level in %, Battery run time in min. Display of UPS metering functions, event history, configuration of parameters and helps perform critical UPS Operations Supports 14 Languages(Chinese, Czech, Dutch, English, Espanola, Francais, German, Italiano, Polish, Portuguese, Russian, Slovensko, Soumi, Swedish) Touch screen Push Buttons Inverter On Inverter Off OPTIONAL FEATURES RPA eboost (Multi-Mode) Dual Input Input/Output Transformers External Maintenance Bypass Protection Software SNMP Communication -Redundant Parallel Operation -High Efficiency Operating Mode for Single and Multi module applications -Integral to UPS cabinet. No additional cabinet required -Available in external cabinets for isolation or voltage transformation -Available in external or as a part of output switchgear cabinet -PC operated remote monitoring, control and diagnostics -Ethernet interface for network connection 6

MECHANICAL DATA 160/200/225/250 kw Enclosure Dimensions (inches / mm) Configuration Width (W) Depth (D) Height (H) 44.10/1120 34.06/865 75.00/1905 Weight (lbs./ Kg) floor load (lbs./sq ft / Kg/sq m) 1323/600 127/620 UPS BLOCK DIAGRAM 1 Rectifier Standard configuration With separate Bypass Mains 2 Inverter 3 Static Bypass 4 Load switch 5 Utility 6 Load Output 7 External Battery 8 RPA Cable Saver Inductor 9 Booster/Charger FB/CB3 Battery Fuses or Circuit Breaker F1, F2, F3 AC Input Fuses or Circuit Breaker 5 Utility F3 L1/L2/L3/N/PE 8 K4 TLES_UL_225-500_S2B_BD Common input_us_01_tds 1 K6 3 2 9 FB/CB3 (option) K7 7 4 Q1 6 LOAD L1/L2/L3/N/PE With separate Bypass Utility: connect a single input Neutral to Bypass Utility (inside the UPS, common neutral for Bypass and Rectifier) 7

Notes DEE-596, Rev. 01/2018 - V001 *Trademark of General Electric Company. Copyright 2015 General Electric Company. All Rights Reserved. GE reserves the right to make changes to specifications of products described at any time without notice and without obligation to notify any person of such changes. 601 Shiloh Road, Plano, TX 75074 +1 877 546 3243 (toll-free in North America) +1 972 244 9288 (direct number) info.criticalpower@ge.com 24/7 Technical Support pe.techsupport@ge.com