n Lower energy costs and carbon footprint n Cooler operation extends internal component life n High input power factor of 0.99

Similar documents
n Lower energy costs and carbon footprint n Cooler operation extends internal component life n High input power factor of 0.99

Series. On-line, Single-phase Parallel Redundant UPS System. 6 and 10 kva Rack Mount. Your Tailored Power Solutions Provider TM

Series. Full Three Year Warranty. On-line, Single-phase Parallel Redundant UPS System. 6 and 10 kva Tower. Your Tailored Power Solutions Provider TM

TLE Series UPS 400/500 kw With eboost Technology

UniStar III Series. Full Three Year Warranty. On-line, Single-phase UPS System. 1, 2, & 3kVA Tower Model

Product Specifications

TECHNICAL DATA SHEET KVA UPS Systemss

TLE Series UPS 750/1000 kw With eboost Technology

TLE Series UPS 160/200/225/250 kw with eboost Technology

Technical Data Sheets

Cobra 3 Stand-By Emergency Central Lighting Inverter (CLI) Technical Specifications

MGE TM Galaxy TM 7000

Defender Mini Online Emergency Central Lighting Inverter (CLI) Technical Specifications

MGE TM Galaxy TM 7000 GFC

Model ESV Uninterruptible Power System 1.5 KVA/KW KVA/KW Single Phase

G V Series UNINTERRUPTIBLE POWER SYSTEMS. Phone: Fax: Web:

Fortress 1 Outdoor Emergency Central Lighting Inverter (CLI) Technical Specifications

Power Lynx 3 Uninterruptible Power System (UPS) Technical Specifications

PowerWave 33 Efficient power protection for today s IT and process-related work environments

Green Power 2.0 MASTERYS GP

Fortress 3 Harsh. Harsh Environment. Emergency Central Lighting Inverter (CLI) Technical Specifications

MKN-DSP SERIES - THREE PHASE

TELECOM- MUNICATIONS DEVICES INDUSTRIAL EMERGENCY DEVICES. (Servers Farms, ISP/ASP/POP)

D Series: UPS UPTO - 300KVA - Three / Three Phase

TELECOM- MUNICATIONS DEVICES INDUSTRIAL EMERGENCY DEVICES. (Servers Farms, ISP/ASP/POP)

KEOR HP. THREE-PHASE UPS from 100 to 800 kva GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

Three-phase UPS system DPA UPScale ST kw The modular UPS designed for lowand medium-power applications

Technical Data Sheets

KEOR HP. THREE-PHASE UPS from 100 to 800 kva GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

DELPHYS GP. Green Power 2.0 range 160 to 1000 kva/kw

TECHNICAL DATA SHEET B8033FXS kva 3Ph(In) 3Ph(Out)

WHY STACO ENERGY PRODUCTS?

POWER kva

TECHNICAL DATA SHEET B8031 FXS kva 3Ph(In) 1Ph(Out)

Features and Benefits

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

POWER kva

TECHNICAL DATA SHEET INFINITY kva 3Ph(in) 3Ph(out)

EFFEKTA Power Supplies

POWER kva Nominal output power (Cos φ0,8) kva Nominal output power (Cos φ1,0) kw >88 Efficiency (AC AC)

Galaxy VM. From 160 kva to 1000 kva. Three-phase power protection. Galaxy VM trusted partner for your business continuity. schneider-electric.

On-line, Single Phase, Double Conversion UPS

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

EMERGENCY ELECTRO- MEDICAL INDUSTRIAL PLCS DEVICES. (Lights/Alarms)

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

gimagination at work Technical data sheet Uninterruptible Power Supply LP Series 6 & 10 kva GE Digital Energy

Industrial PFC UPS System

Technical Data Sheets

Technical Data Sheets

Liebert NXC. 10kVA - 60kVA. Compact, Efficient, and Reliable Power Solution

GUIDE SPECIFICATION THREE PHASE UNINTERRUPTIBLE POWER SUPPLY

G9000 UNINTERRUPTIBLE POWER SYSTEMS

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

INDUSTRIAL PROCESSES TELECOM- MUNICATIONS DEVICES EMERGENCY DEVICES INDUSTRIAL

3 Uninterruptible Power Systems

MASTERYS IP+ 10 to 80 kva

Standard 1000VA, 2000VA & 3000VA Universal Tower/Rack Mount LB Extended Models 900VA, 1700VA & 2500VA

Master Plus kva

Series 120/120VAC Universal Tower/Rack Mount

Technical Data Sheets

G9000 UNINTERRUPTIBLE POWER SYSTEMS

3 Uninterruptible Power Systems

TOSHIBA /20/25/30/50kVA Internal Battery GUIDE SPECIFICATION THREE PHASE UNINTERRUPTIBLE POWER SUPPLY

GUIDE SPECIFICATION THREE PHASE UNINTERRUPTIBLE POWER SUPPLY

Technical Data Sheets

Illuminator Series CR NEMA 3R

Symmetra PX 250/500. Scalable from 100 kva kw to 500 kw, parallel capable up to 2,000 kw

Symmetra PX. Industry-leading efficiency, availability, and performance for small, medium, and large data centers and mission critical environments

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

SmartOnline SUT Series 3-Phase 208/120V 220/127V 30kVA 30kW On-Line Double- Conversion UPS, Tower, Extended Run, SNMP Option

Galaxy VM. From 160 kva to 1000 kva, 160 kva or 200 kva modular approach. Three-phase power protection

Standalone three-phase UPS system. PowerWave kw Unmatched power performance

SmartOnline S3MX Series 3-Phase 380/400/415V 60kVA 54kW On-Line Double-Conversion UPS

Galaxy VM. From 160 kva to 1000 kva Three-phase power protection. apc.com/products

Symmetra PX 100 kw. Scalable from 10 kw to 100 kw Modular, scalable, high-efficiency power protection for data centers

kVA. Liebert NX. Enterprise-Scale UPS Protection For Medium And Large Data Centers

Technical Data Sheets

SmartOnline SUT Series 3-Phase 208/120V 220/127V 20kVA 20kW On-Line Double- Conversion UPS, Tower, Extended Run, SNMP Option

Three-phase UPS system. DPA UPScale ST kw Best-in-class modular UPS for maximum availability

Technical Data Sheet. Uninterruptible Power Supply. Digital Energy. imagination at work

Liebert. FP 50Z kva

Technical Data Sheets

PowerValue 11/31 T kva

Technical data sheet VH UL. Digital Energy Uninterruptible Power Supply. GE Digital Energy Power Quality

Symmetra PX 96/160. Scalable from 16 kw to 160 kw Modular, scalable, high-efficiency power protection for data centers

MODULAR THREE-PHASE AND SINGLE-PHASE UPS SYSTEM

Features and Benefits

POWER+ PREMIUM CBS. BS-EN Emergency electrical installations Electric power systems Emergency lighting Escape lighting

SmartOnline SVTX Series 3-Phase 380/400/415V 20kVA 18kW On-Line Double-Conversion UPS, Tower, Extended Run, SNMP Option

Est FlexiPower Mini UPS FPX Mini kVA

Eaton 93PS 8-40kW UPS Technical Specification Manufacturer s declaration in accordance with IEC

Master MPS kva kva 3:1 3:3 VFI TYPE

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

TOSHIBA G , 750kVA

LIEBERT APM 3-PHASE UPS: 15-90KVA/KW, 60HZ, VAC, SINGLE & DUAL INPUT - SITE PLANNING DATA

1.1 GENERAL CHARACTERISTICS

U N I T Y / Three-Phase Uninterruptible Power Systems UT380 and UT Hz

60 to 160 kva.

Standalone three-phase UPS system. PowerWave kw Unmatched power performance

PowerWave 33, kw

Transcription:

65-500 kva Full Two Year Warranty Three-Phase Double-Conversion On-Line Up to 98% Efficient n Lower energy costs and carbon footprint Compact & Reliable n Requires either front, top or bottom access, so it can be placed against a wall to minimize footprint n Cooler operation extends internal component life AC Input Performance n High input power factor of 0.99 n Low input current distortion of < = 3% n Power walk-in function that ensures progressive rectifier start-up 2 Level IGBT and DPS Processing n Reduces the impact of the on the local supply n Simplifies installation where there is limited power capacity in the form of available electrical supply rating or generator size Single or Dual input n Main power and secondary emergency standby power increase resilience of single or parallel system configuration High Performance Filter n Protects upstream power supply sources from harmonics and reactive power generated by the loads Menu Select Display n User friendly display is easy to see and intuitive to use Parallel up to 8 Units n Provides redundancy for mission critical applications with no additional hardware Seismic Certified n For environments requiring seismic certification, the P Series is available with an optional OSHPD Certified mounting system which makes the and Battery Cabinet(s) OSHPD Certified. (excludes 300-500kVA units) Worldwide Service Program n Factory trained service personnel maximize equipment life n Full start-up service & preventive maintenance lowers cost of ownership Your Tailored Power Solutions Provider TM

FirstLine P In the event of an AC power failure, the FirstLine P will automatically transfer to battery power and continue to provide power without any interruption for the full amount of time you select. When power returns, the FirstLine P will automatically recharge the batteries for the next unexpected power outage or disturbance. AC Input Performance FirstLine P is a further evolution of the FirstLine series with the added advantages offered by an IGBT-based rectifier/inverter assembly. This feature reduces the impact of the on the local supply and simplifies installation where there is limited power capacity in the form of available electrical supply rating or generator size. FirstLine P is classed as a Zero Impact Source and provides: n Low input current distortion < = 3% n High input power factor 0.99 n Power walk-in function that ensures progressive rectifier start up n Delayed start up phased with the return of mains power supply, when several are connected in the system. FirstLine P also performs the role of a high performance filter, protecting its upstream power supply sources from any harmonics and reactive power generated by the loads powered. Flexibility FirstLine P models feature an output transformer with galvanic isolation (between the load and the battery supply) to provide greater versatility and installation options. The can be supplied from two separate power sources (main power and a second emergency standby source) which helps increase the resilience of parallel system configurations. Main Characteristics n Efficiency up to 98% n Reduced weight n Double electronic and galvanic protection of the load from the battery The entire FirstLine P range is suitable for a wide range of applications thanks to the flexibility of configurations, accessories, options, and choice of performance levels. The is compatible with capacitive loads, such as blade servers, without any reduction in active power, ranging from 0.9 lead to 0.8 lag and up to 0.8 capacitive power with a low derating equal to 15% of the active power (kw). Efficient and reliable power supply for mission critical applications is guaranteed by operating in redundancy and power parallel mode with up to 8 units (N+1), and by the Dual Bus System and Dynamic Dual Bus system configurations. FirstLine P www.stacoenergy.com

Battery Care System FirstLine P uses the Battery Care System which optimizes battery performance while extending battery life. Front Panel Display FirstLine P shown with optional external battery cabinet Applications n Data Centers n Computer Networks n Industrial Process Manufacturing n Hospitals/Medical (OSHPD Certified) n Education/Research n Laboratories, Bio-Tech n Pharmaceuticals/Chemical n Critical Power Management Requirements n Any areas needing computer grade power and a high level of available power Two Year Warranty Electronics: A full Two Year On-site Warranty (Continental U.S.) Battery: Three (3) Year Full, Limited Warranty, on the Battery System ensures that your batteries are protected from system failure now and in the future. (Warranty provided by battery manufacturer.) Extended warranties, customized service plans and preventative maintenance are also available. Please refer to our warranty statement for complete details. Staco Energy Products Co.

Electrical Specifications Electrical Data Power (kva / kw) 65 / 58.5 80 / 72 100 / 90 125 / 112.5 160 / 144 200 / 180 250 / 225 300 / 300 400 / 400 500 / 450 INPUT Nominal voltage 480Vac 3 phase, 3 or 4-Wire + Grd. (208V Optional with Input Transformer) Nominal voltage range without battery contribution -10%, +15% Voltage range in battery mode -40%, + 15% Input frequency range From 45 to 65Hz Nominal current absorbed (480V) 76 94 118 147 188 235 294 320 425 484 Maximum current absorbed at full load and battery recharging (Amps) 89 109 136 160 212 265 331 433 640 640 Power factor at nominal voltage (480 V) and battery charged from 25% to 100% of the load >0.99 Current Harmonic distortion (THDi) (with mains distortion <2%) load 100% load 75% load 50% load 25% Progressive rectifier (Walk-in) Delay of Progressive start of rectifier (Power Walk-in delay timer) 3% 5% 8% 8% from 0 to 125 seconds (configurable) from 0 to 125 seconds (configurable) D.C. INTERMEDIATE CIRCUIT Number of cells 240 INVERTER Static variation ± 1% Dynamic variation ± 5% Crest Factor 3:1 Voltage distortion with linear load 1% (typical), 2% (max) Voltage distortion with non-linear load < 3% Frequency stability with synchronized inverter to the by-pass network. ± 2% ( ± 1% to ± 6% from control panel) Frequency stability with not synchronized inverter to the by-pass line ± 0.05% Speed of frequency variation 1Hz/sec (parallel units can be calibrated from 0.1 to 1Hz/s) Phase voltage asymmetry with balanced and unbalanced load. 1% Phase displacement of the voltages with balanced and unbalanced loads. 120 ± 1 el Overload in referred to the nominal power l Three phase 110% for 60 minutes, 125% for 10 minutes, 150% for 1 minute 200% for 7 seconds l Single phase Inverter efficiency 95% BY-PASS Nominal voltage 480Vac 3-phase (with or without neutral) Nominal voltage tolerance ± 10% (can be regulated from ± 5% to ± 15% from the control panel) Nominal frequency 60 Hz Frequency tolerance ± 2% (can be regulated up to ± 6% from the control panel) SYSTEM AC/AC efficiency at full load 93 % Efficiency with in STAND-BY mode 98 % Full Load Heat Rejection BTU/hr 15,033 18,500 23,120 28,900 37,009 46,262 57,827 56,150 74,870 84,225 Maximum current dispersion 300mA maximum MECHANICAL Dimensions Power (kva / kw) 65 / 58.5 80 / 72 100 / 90 125 / 112.5 160 / 144 200 / 180 250 / 225 300 / 300 400 / 400 500 / 450 Height x Width x Depth inches (mm) -00 75.02" x 31.43" x 33.47" 75.02" x 39.37" x 33.47" (1905.5 x 798.2 x 850.0) (1905.5 x 1000.0 x 850.0) 74.80" x 59.06" x 39.37" (1900.0 x 1500.0 x 1000.0) -T - 75.02" x 55.12" x 33.47" -CEC 75.02" x 31.43" x 33.47" (1905.5 x 1400.0 x 850.0) (1905.5 x 1198.2 x 850.0) 74.80" x 74.80" x 39.37" (1900.0 x 1900.0 x 1000.0) -T-CEC - - Weight lbs. / Kg -00 1,499 / 680 1,609 / 730 1,742/ 790 1,984 / 900 2,205 / 1,000 2,425 / 1,100 4,190 / 1,900 4,741 / 2,150 -T - 2,236 / 1,055 2,546 / 1,155 2,767 / 1,255 4,200 / 1,905 4,751 / 2,155 -CEC 1,749 / 793 1,859 / 843 1,992/ 904 2,234 / 1,013 2,455 / 1,114 2,675 / 1,213 4,410 / 2,000 4,961 / 2,250 -T-CEC - - 4,420 / 2,005 4,971 / 2,255 Freestanding NEMA 1 enclosure, powder coat painted black color with textured finish, bottom access for conduit entries ENVIRONMENTAL Ambient temperature 0 C to 40 C Storage temperature -25 C to 70 C Relative humidity 20 90% non-condensing Altitude 3,281 feet without derating Audible noise 65 dba @ 1 meter 68 dba @ 1 meter 72 dba @ 1 meter FirstLine P www.stacoenergy.com 3% 3% 5% 8%

Single Input Unit A G E B Dual Input Unit G C D F 1 2 3 4 A Control panel with graphic display B Door handle C Ventilation grills D Communication area E Front Cover panel with ventilation grills F Switch cover panel G Door 1 Input isolating switch 2 Output isolating switch 3 Maintenance isolating switch 4 Bypass isolating switch FirstLine P 65 500kVA Part Numbers Model kva / kw ² FLU-065-00 65VA/58.5kW ² FLU-080-00 80kVA/72kW ² FLU-100-00 100kVA/90kW ² FLU-125-00 125kVA/112.5kW ¹ FLU-160-00 160kVA/144kW ² FLU-160-T 160kVA/144kW ¹ FLU-200-00 200kVA/180kW ² FLU-200-T 200kVA/180kW ¹ FLU-250-00 250kVA/225kW ² FLU-250-T 250kVA/225kW ¹ FLU-300-00 300kVA/300kW FLU-300-T 300kVA/300kW ¹ FLU-400-00 400kVA/400kW FLU-400-T 400kVA/400kW ¹ FLU-500-00 500kVA/450kW FLU-500-T 500kVA/450kW Standards l Underwriters Laboratories, Listed to UL1778 (Designed to 60950); c-ul to CSA C22.2 l CE l NEMA PE-1 l ASME l ASA-C-39.1-1984 l FCC PT 15, Subpart J, Class B l National Electrical Code l OSHA l IEEE 587 ANSI C 62.41-1980 l ISO 9001 l IBC (International Building Code) Ratings A-F, Site Specific l OSHPD (excludes 300-500kVA units) ¹ Models do not have internal bypass. Order -T unit when an internal bypass is required. ² For OSHPD, add "-S" to model number. Top entry available. FirstLine P Up to Eight Units in Parallel Staco Energy Products Co.

Communication Options SNMP Card with MON Monitoring and Shutdown Software allows for single unit management across a LAN using any of the main network communication protocols TCP/IP, HTTP and network interface (SNMP). A SNMP Card enables the to integrate easily into medium and large sized networks and provides reliable communications between the and management systems employed. Battery Sensor Module monitors the battery internal cabinet environmental conditions of one (1) Battery Cabinet connected to the and displayed on the front mimic panel. Expansion Card provides additional remote alarm functions as identified below. The card contains 6 outputs: potential-free contacts for alarms (programmable from the display panel) and capable of switching up to 30 V AC or DC at UP 1 Amp, 2 inputs (programmable from the panel) and (1) 12V DC maximum 100mA auxiliary input. (2) additional slots shall be available for a total of 12 additional contacts. Remote Monitoring Panel provides monitoring & control of the remotely (same functions as on the ) and detailed status overview in real time. It is compatible with all FirstLine P 's and can display values for specific input and output supplies, and battery set measurements. It has a high-definition graphical display and can report in seven languages: English, Spanish, French, Chinese, German, Italian and Russian. Includes three independent serial ports, one of which allows for monitoring via the MODBUS/JBUS protocol (on either an RS485 or RS232 serial line). The others can be used with devices such as the SNMP Card or a PC running communication software. Communicaiton Software used with the SNMP Card for monitoring and shutdown for multiple 's. Provides efficient, userfriendly management using bar chart displays to show major operational information such as the input voltage, load % and batteries charge %. The software also provides detailed information on fault conditions and operating characteristics. It has been developed with a client/server architecture that makes it flexible and easy to use, and provides multi-lingual and on-line support. Supervision Software centralizes management using network interface (SNMP) communications. It is ideal for data center managers and medium to large sized networks. It uses the RFC1628 standard Management Information Base (MIB) and ensures standardized management wherever they are located. Other Options Top or Side Cable Entry A side-car cabinet expansion is offered to accommodate top or side incoming cable entry. External Maintenance Bypass, 3 Breaker with Electronic Interlocks Make-Before-Break, Line Up and Match wrap-around MBP for total isolation during maintenance or removal of the. Power Distribution Unit (PDU) Transformerless PDU provides 208Y/120VAC output electrical distribution capabilities to peripheral devices. Line Up and Match Cabinet with (2) 42 Pole Panelboards or Sub-Feed Circuit Breakers. ( output must be 208Y/120VAC) Battery Monitoring System (BMS) The FirstLine BMS is a wireless system that monitors and records battery cycle data of each battery string or jar. Provides a clean cable free installation.. Harsh Environment Enclosure and accessories mounted and pre-wired internal, with AC cooling inside any NEMA (12, 3R, 4X) type enclosure. Seismic Withstand Certification Site specific seismic certification and documentation. All units come standard with bolt down capability without the use of brackets. Start-Up Service, Preventative Maintenance Programs A wide range of service programs are available to suit all user requirements. Consult factory. FirstLine P www.stacoenergy.com

Service Options Staco Service offers a wide range of planned maintenance and extended service options to maximize equipment life and reliability of your FirstLine. Through an extensive network of factory trained professionals you receive: Annual Service Plan 24/7 Emergency Service Preventive Maintenance Programs tailored to meet your needs About Staco Energy Products Since 1937, customers worldwide have been relying on Staco Energy Products Company to deliver voltage control and power quality solutions tailored to their needs. As a leading power quality resource, we offer our customers world-class support; from our thorough applications assessment, to our ability to design and deliver a solution that is tailored to the specific needs of our customers; through delivery and commissioning. In addition to the FirstLine products we offer a wide array of power quality products, including: Uninterruptible Power Supplies Power Conditioners Voltage Regulators Power Factor Correction and Harmonic Mitigation Active Harmonic Filters Variable Transformers Custom Engineered Test Sets Our professional, factory trained service team is in place to ensure that our customers revenues are protected, and their investment provides them with many years of trouble free operation. Staco develops total power solutions for OEM and end user applications. Represented locally by: Your Tailored Power Solutions Provider TM 2017, Staco Energy Products Co. FL-P_bro-170524