Power Back Up Product Announcement

Similar documents

2017 Clearance Sale. Updated

Battery Enclosure Installation Instructions

XW E-Panel installation manual

Complete Kits to Assemble on Site All our FLEXware systems are available as parts kits to assemble in place. All parts are UPS shippable.

Let s start simple. What is an AC-Input/Output Bypass switch? Why do I need one?

Apollo Solar Inverter Switchgear Module Installation Manual Rev 1.2 Page 1

SAVE THESE INSTRUCTIONS

MNPV Installation Instructions

672W Off Grid Residential Package

Midnite Kid Basic Solar Charging Kit

Off Grid Cabin Special Pkg 1-170W PV

Off Grid Residential Package 1.0KW

MNBRATKIT MidNite Brat Solar Charging Kit

MX60 and FX Inverter production lines each ship 10,000th unit. Thank you for your support as we continue Powering the Planet.

E-Panel Instructions. Regular (narrow) OutBack E-Panel parts. OutBack E-Panel as installed (narrow)

MNPV2, MNPV3, MNPV4, MNPV6 Instructions

SAVE THESE INSTRUCTIONS

User s Guide. Includes Mounting, Installation, and Product Registration

User s Guide Includes Mounting, Installation, and Product Registration

MNPV 3. MNPV Combiners. Been mooned lately?

FW-IOB-T-120/208VAC Input/Output/Bypass Assembly. Installation Instructions

MNE-240 Series E-panel Owner s Manual

INVERTER CHARGERS MODEL DESCRIPTION MSRP

Components for your PV Solar Electric System

MNDC-X2 INSTRUCTIONS

GRANITE ENCLOSURES MODEL NO. NPS Standard Features

Pure Sine Wave Inverter Charger

Radian Series Inverter/Charger GS7048E GS3548E. Installation Manual

MidNite Solar. Electrical DistributioN Power Panels

Parts Catalogue. Solar (PV) Panels. Mounts. Inverters. Power Panels. Battery Monitors. Charge Controllers. Meters. Batteries. And more...

MNPV6 Disco / MNPV6-250 MNPV6-AC Disco Installation Instructions

Special Specification 6058 Battery Back-Up System for Signal Cabinets

Magnum AC Coupled In a D3R battery box MND3RACCPLME 7/20/18

Solar PV Standard Electrical Plan

SPECIAL SPECIFICATION 8676 Solar Panel Power Supply System

Coleman Air ITS-240 Inverter Transfer Switch

Solar Inverter Manual

Oberbauer/ITEX Solar Power Systems

2011/2008/2005 NATIONAL ELECTRICAL CODE SOLAR PV CODE COMPLIANCE REFERENCE

Steca Elektronik INVERTER / CHARGER WITH MPPT: SOLARIX PLI

Server and Broadband Enclosures a r e t n a P

Micro3 Grid Tied Residential Package

Outdoor Enclosure Power System ENC X100MP48F20

How To AC Couple Grid Tied Inverters with OutBack Frequency Shifting Inverters

GS-IOB-120/240VAC. Input/Output/Bypass Assembly. Installation Instructions. Purpose. Scope. Requirements. Grounding Instructions

PSX-240 Enclosed Autotransformer Installation Manual

Xantrex XW System The NEW Standard

DC to AC Power Inverters

DC to AC Power Inverters

new energy leads low carbon life.

Evolution of the E-Panel

Contractors Guide Central Inverter System Installation

BRAVO Inverter/Battery Charger. Table of Contents

R series solar charger inverter 1000W to 6000W

Current Automation Catalogue Page 27

Coleman Air ITS-240 Inverter Transfer Switch

Job Sheet 6 Installing the Combiner Box

Product Guide Powering the Planet, One System at a Time

AMENDMENT ELECTRIC SERVICE MANUAL 2014

String Sizing with SkyBox

Using Inverter Input Modes for Smart Grid Management

CLASSIC MPPT CHARGE CONTROLLERS

Two Seas Metalworks Shell Lane fax Rev

Outdoor Enclosure Power System ENC X100MP48F20-AC6

Code Calculations. for an Off-Grid PV System

How To Set Up SimpliPhi Batteries Using OutBack Chargers

YOUR POWER STORAGE SOLUTION!

NetSure 5100 ORDERING GUIDE. 48V & 24V DC Power System (40 A to 600 A)

Export FX and VFX Inverter/Charger. Installation and Programming Manual. Document Revision 7.0

Off Grid System Design

Solar Electric Product Catalog

K50. Technical Sheet

EXPANSION JOINT DETAILS DURA-BLOK CONDUIT SUPPORT CONDUIT ATTACHMENT DETAIL SCALE: NOT TO SCALE GROUNDING WIRE DETAIL SCALE: NOT TO SCALE

First Responder System Identification Quiz. Presented by the NY-SUN PV Trainers Network

Dimensions 12/800N 12/1200N D. DC to AC Power Inverters. OWNERS MANUAL for Models: OWNERS MANUAL April ISO 9001:2000 Certified Company

Radian Series Inverter/Charger GS7048E. Installation Manual

FX Inverter/Charger. FX and VFX Mobile Series. Installation Manual

LARGE CAPACITY INCUBATOR Installation, Operation and Maintenance Instructions

Model ESV Uninterruptible Power System 1.5 KVA/KW KVA/KW Single Phase

EnergyCell Battery. Owner s Manual

MECKLENBURG COUNTY. Land Use and Environmental Service Agency Code Enforcement 2/8/12 ELECTRICAL CONSISTENCY MEETING. Code Consistency Questions

Operator s Manual: Solar Charging Station

GS-IOB-230VAC. Input/Output/Bypass Assembly. Installation Instructions. Purpose. Scope. Requirements. Grounding Instructions

DCCB-L DCCB-L-175 DCCB-L-250. Owner s Guide. Sine Wave Plus DC Conduit Box Long

Using OutBack Inverters for 3-Phase 480V Applications

Steca Elektronik SOLARIX PLI

OFF GRID Solar system

RFQ-YEM Solar Lighting System for UNDP

SOL-ARK 8K We guarantee it s the most effcient & affordable Multi-Mode Inverter in its class

Generator/Loadbank Quick Connection Tap Box

Solar PV Standard Plan Simplified Central/String Inverter Systems for One- and Two-Family Dwellings

Solar PV Standard Plan Simplified Central/String Inverter Systems for One- and Two-Family Dwellings

Battery Power Inverters

Solar Photovoltaic (PV) System Components

MNPVHV Disco Installation Instructions

FLEXmax Extreme Charge Controller

Expense Report. spare muffin fans 29% ventilation 47.48% latch & cement board 23.05%

Solar Power Switchgear & Energy Storage Renewable Energy Systems

Sunwize Power Ready Express Quick Start

Transcription:

Power Back Up Product Announcement MNBE-C -250 Gen/Grid MNBE-B-175 Gen/Grid C enclosure configured for battery backed up grid tie using OutBack Power electronics Transfer switches and circuit breakers are concealed under a hinged door Power Back Up enclosures are based on the MidNite Solar MNBE-C and MNBE-B enclosures. These new Power Back Up systems are result of many years of designing and building off-grid and power back up equipment. Only now have we actually combined all the features into a system that is not only cost effective and cosmetically pleasing, but flexible in all aspects.

The C enclosure has three shelves. The top shelf comes pre-wired similar to the following images. The standard enclosure is designed for two strings of batteries at 48 volts. The large tin plated copper bus bars shown below are options, however smaller busbars for battery plus and battery minus are supplied in order to accommodate two strings of batteries. The large bus bars shown in the image below are available at additional cost if required. ($91.00 each) Internal wiring showing the optional plus and minus busbars. Magnum modified inverter installed in the C system enclosure. This picture shows a 120mm x 25mm 12VDC fan mounted to the left side panel. Each cabinet comes with a stainless steel mesh and a spacer to mount the fan 5/8 away from the side to reduce noise. These fan spacers are on order from China and may not be available until June 07. Notice the fan wires running to the aux output of the GVFX inverter. The aux output powers this fan directly. This picture shows a plate that covers a fan opening on the opposite right side panel. This plate can be purchased as a separate piece to cover the fan mesh if desired. MidNite Solar part number Fan Cover Plate. The cost for this part is $18.00. MX60 mounting bracket is also $18.00. The AC wiring shown here is pre-installed and all field wiring terminals labeled. This particular system has a charge controller that has been added in the field. A DC-GFP and two charge control breakers have been added on the left of the factory breakers. Systems with the Gen/Grid option do not have space for these additional charge control and DC-GFP breakers inside the cabinet. MidNite offers the Baby Box to accommodate these four breaker spaces outside the enclosure. Battery cables will not be furnished as standard so installers can configure for different batteries and voltages although the inverter cables are standard. The 2/0 inverter cables supplied will accommodate either the OutBack or Magnum Energy inverters. Battery cables can be made upon request at additional charge. The B enclosure battery shelf holds four group 31 or T105 sized sealed batteries. The C enclosure has two battery shelves that each can accommodate four group 31, T105 or the new taller and more powerful Concorde PVX-3050T AGM batteries. Four group 31 batteries = 4000 useful watt hours of power while eight PVX 3050T s have about 10,000 watt hours of useful 80% depth of discharge power. 1000WH will run a 500 watt load for 20 hours.

Features and components included: Gray texture powder coated enclosures GFCI outlet, wired with 15 amp breaker Nine CBI breakers: 15 amp AC for outlet, two 50 amp AC for bypass switch, 50 amp AC for AC input, three AC load breakers either 15 amp or 20 amp or any combination. Two more 50 amp breakers for the generator/utility transfer switch option. All breakers are hydraulic/magnetic and do not need to be derated for 80% of rating. 175 or 250 amp breaker mounted. AC ground bus bar AC input and output terminal blocks for field wiring connections AC breakers wired with 8AWG wire. Bus bar on battery disconnect breaker for connecting two parallel strings of batteries 500 amp/50mv shunt for connection of battery and inverter negatives with bat negative busbar. Long bolt on shunt to accommodate multiple lugs 2/0 inverter cables to fit Magnum or OutBack inverters AC inlet for portable generator Leviton #5278C recessed power inlet module Mounting hardware for Magnum or OutBack inverter keyed lock supplied for door keeps unauthorized people out Dual hinged doors with recessed handle on right hand door. Flip down panel to conceal circuit breakers from view 2 side knock outs to accommodate additional battery enclosures side by side Will accommodate OutBack or Magnum inverters B cabinet has one shelf for batteries and C cabinet has two C Models: MNBE-C-175 Gen/Grid, MNBE-C-250 Gen/Grid, B Models: MNBE-B-175 Gen/Grid, MNBE-B-250 Gen/Grid List price for each C enclosure as identified is $2349.00 USD, fob Arlington, WA. 98223 List price for each B enclosure as identified is $2229.00 USD, fob Arlington, WA 98223 Magnum inverters can be installed by Midnite. The MS4024 4000 watt sine wave lists for $2399. The Magnum RD2824 modified sine inverter with power factor corrected charger lists for $1529. The cabinets can come minus the generator input and transfer switch. This allows for up to 4 additional DC or AC breakers. Drop the Gen/ from the model number and deduct $180 off the list price. The medium battery enclosure (MNBE-B) is configured and wired like the large C size enclosure. Pictures of a very recent prototype Outback version cabinet below. Wiring compartment shown with top removed. Breakers with cover removed. Note the PV and DC-GFP breakers on this system.

MNBE-C enclosure with twelve Concorde PVX-3050T s installed MNBE-B enclosure with eight Concorde PVX-2240T s installed For additional run time, add another battery enclosure side by side. Two inch knock outs on the side panels facilitate running cables from one cabinet to the other. Use a 6 inch long 2 nipple to connect the cabinets together and act as the cable conduit. MNBE-B-50 Grid as it comes from the factory