Cargo Handling Sheet. Caradol SC Document date: 4 June 2014 Revision 6

Similar documents
Cargo Handling Sheet. Caradol SC Document Date 2 Oct 2014 Original document

Cargo Handling Sheet. Caradol MC Document Date 3 March 2015 Revision 1

Cargo Handling Sheet. Caradol SA Document date: 11 April 2013 Original document

Cargo Handling Sheet. Caradol SP Document date: 19 March 2013 Revision 4

Cargo Handling Sheet. Caradol SP Document date; 7 January 2014 Revision 6

Cargo Handling Sheet. Caradol SC Document date: 22 April 2013 Revision 3

Cargo Handling Sheet. Methyl Ethyl Ketone (MEK) Document date: 3 June 2015 Revision 3

Cargo Handling Sheet. Ethylene Glycol all Grades. Document date: 29 June 2015 Revision 9

Cargo Handling Sheet. Styrene. Document date: 21 November 2013 Revision 5

Shell MDS (Malaysia) Sendirian Berhad

Terminal Heide. Site Requirements.

MARPOL Annex I and Changes to the Oil Record Book Parts I and II.

Emission control at marine terminals

Neutral Oils : 60R, 110RVL, 100R, 150R, 220R, 600R

SHELLSOL D60. Shell Chemicals. Data Sheet. Lemont, IL Cotton Valley, LA. Product Name

THERMINOL 75. heat transfer fluid. Ultrahigh temperature at low pressure. 80 to 385 C. (175 to 725 F)

REVISED CONSOLIDATED FORMAT FOR REPORTING ALLEGED INADEQUACIES OF PORT RECEPTION FACILITIES

ANNEX 23. RESOLUTION MEPC.187(59) Adopted on 17 July 2009

Determining Cargo Authority. Rev. 0, 11/17

Report No.: Name of Ship: Plans referred during Initial Survey:

Meeting ECA requirements a new challenge & a new opportunity

We re Going Global. Washing walls, wall wash sounds the same? Yes, they do but they couldn t be more different.

FRESH SOLUTIONS FOR PAINTS AND COATINGS

ST. VINCENT AND THE GRENADINES

Creating a zero-emissions shipping world

Cargo Residues? 14 October Luk Wuyts

AMENDMENTS TO MARPOL ANNEX I AND CHANGES TO THE OIL RECORD BOOK PARTS I AND II

Technical Circular. No.: 025 Date: 6 th November 2014

THE IMPACT OF REGULATIONS ON MARINE FUEL QUALITY

IEA Bioenergy ExCo78 workshop Biofuel supply to Interislander

Technical Information

Enforcement of low sulpher requirements in the low lands

International and European Shipping Policies and the Protection of the Marine Environment

Guidelines for PSCOs on the Inspection Campaign on MARPOL ANNEX VI

ff## MINISTRY OF TRANSPORT AND COMMUNICATIONS DEPARTMENT OF MARINE ADMINISTRATION Directive ( )

Ballast Water Treatment Technologies: The Regulations, Which System and When to Install

-5 F to 620 F. High Performance, Low-pressure Heat Transfer Fluid. Heat Transfer Fluid by Solutia. Technical Bulletin A +400 C +700 F +350 C

Polyalkylene glycols are much less soluble in ethylene than are white oils or polyisobutylenes. Therefore a two fold advantage is observed:

Bunkering With New Fuels Building on Strong Foundations.

Pyrophoric Ignition Hazards in Typical Refinery Operations

People - Ideas - Solutions

CONTROL OF OIL RESIDUES (SLUDGE) AND MARPOL ANNEX I

NORTH AMERICAN ECA AND NEW FUEL SULFUR CONTENT REQUIREMENTS

RESOLUTION MEPC.120(52) adopted on 15 October 2004 GUIDELINES FOR THE TRANSPORT OF VEGETABLE OILS IN DEEPTANKS OR IN INDEPENDENT TANKS SPECIALLY

People - Ideas - Solutions Marine

E-class. Evolved design with focus on Efficiency and Environmental care

Form of IOPP Certificate and Supplements * INTERNATIONAL OIL POLLUTION PREVENTION CERTIFICATE

Universal Bevel Drives Service Manual

INTERTANKO Documentary Committee Bunker 2020

ANNEX 18. RESOLUTION MSC.150(77) (adopted on 2 June 2003)

LEGISLATIVE COUNCIL BRIEF. Merchant Shipping (Prevention and Control of Pollution) Ordinance (Cap. 413)

MARPOL Annex VI: the Club s perspective

THERMINOL LT. heat transfer fluid. Wide temperature range, liquid/vapor phase fluid to 315 C. (--103 to 600 F)

China Regulatory Update

THERMINOL 72. heat transfer fluid. High temperature, excellent stability at medium pressure. -14 to 380 C. (7 to 715 F)

Reduced down time for maintenance, Reduced loss of the feedstock due to polymerisation, Less pre-polymer deposits and improved efficiency.

The Need to Reduce Marine Shipping Emissions

MEPC.1/Circ.736/Rev.1 25 August 2011 GUIDANCE FOR THE RECORDING OF OPERATIONS IN THE OIL RECORD BOOK PART I MACHINERY SPACE OPERATIONS (ALL SHIPS)

Monitoring Air Emissions on Ships. Restricted Siemens AG 2014 All rights reserved.

THERMINOL VP-3. heat transfer fluid. High-temperature, low-odor, vapor/liquid phase fluid. 2 to 330 C. (36 to 625 F)

THERMINOL 62. heat transfer fluid. High performance under low-pressure applications. -23 to 325 C. (--9 to 620 F)

IWAKI MAGNETIC DRIVE PUMPS MDM. Patent JAPAN / U.S.A. / TAIWAN / EU / CHINA

ABS Notes. Use of Low Sulphur Marine Fuel for Boilers

THERMINOL 66. heat transfer fluid. Proven performance for high-temperature, low-pressure applications. -3 to 345 C. (27 to 650 F)

A Critical Assessment of Synthetic Lubricant Technologies for Alternative Refrigerants

Sampling & Test Accuracy under the umbrella of emissions legislation

RELATIONS OF DISTRIBUTION OF THE LOW SULPHUR SHIPPING FUELS IN REGION OF THE BALTIC SEA IN THE BUNKERING BOAT-SHIP SUPPLY

CLASSIFICATION NEWS OCTOBER 4, 2005 NO. 13/2005

THERMINOL 55. heat transfer fluid. Efficient, reliable mediumtemperature-range. -28 to 290 C. (--18 to 550 F)

Preliminary Report of MEPC 73

Residual Fuel Market Issues

Standard Diesel & FCC Additive Technical Analysis on Lubricity

FACTSHEET INTRODUCTION SUMMARY

A multi-fuel future: the impact of the IMO sulphur cap

THERMINOL 68. heat transfer fluid. High-temperature, low-viscosity fluid. -26 to 360 C. ( 14 to 680 F)

THERMINOL 54. heat transfer fluid. Efficient, reliable mediumtemperature-range. 28 to 280 C. (- 18 to 540 F)

THERMINOL RD. heat transfer fluid. Low-viscosity, medium-temperature fluid. -36 to 270 C. (--33 to 520 F)

Navigation in emission control area zones

UNITED STATES ENVIRONMENTAL PROTECTION AGENCY OFFICE OF TRANSPORTATION AND AIR QUALITY ENGINE INTERNATIONAL AIR POLLUTION PREVENTION CERTIFICATE

MARPOL Annex VI Emission Control Areas. CDR Ryan Allain U.S. Coast Guard Environmental Standards Division Washington, D.C.

UNITED STATES ENVIRONMENTAL PROTECTION AGENCY OFFICE OF TRANSPORTATION AND AIR QUALITY ENGINE INTERNATIONAL AIR POLLUTION PREVENTION CERTIFICATE

OPINION by CLIA Europe of the proposed revision 1 of the

TECHNYL A 218 BLACK 21N

Monitoring, Reporting and Reducing Air Emissions from Marine Operations. Till Stoeckenius, ENVIRON Int. Corp. GreenTech June St.

NO x FAQ. Disclaimer. Content

IWAKI MAGNETIC DRIVE PUMPS MDM. Patent JAPAN / U.S.A. / TAIWAN / EU / CHINA

v. CRIMINAL INFORMATION Fed. R. Crim. P. 7 COOPERATIVE SUCCESS MARITIME S.A.

SHELLSOL OMS. Shell Chemicals. Data Sheet. This product is manufactured at more than one production site. site below to obtain the right datasheet:

OPEC CAPRI. Opec Petrol Transportation Company Limited Viet Nam / Hai Phong Year Built 2007 WUZHOU ZHONGYUAN SHIPYARD Classification Society

Regulatory Compliance Shipowner Perspective

DELO -PUR 9692 Multi-purpose 2c polyurethane, cures at room temperature, high-viscous, filled

GUIDELINES FOR USE OF LOW SULPHUR FUEL OILS IN SHIPS

VISWA INSTRUCTION FUEL QUALITY TESTING PROCEDURES. Viswa Lab Fuel Oil Analysis

PART II RULE FOR THE CONSTRUCTION AND CLASSIFICATION OF SHIPS IDENTIFIED BY THEIR MISSION TITLE 31 SELECTION OF SHIP TYPE FOR LIQUID BULK CARGOES

High Accuracy Bunker Blending / Bunker Control

ULSFO (0.10) and RM (VLSFO) Category Potential future trends

MARPOL - Revisions of Annex I : Effect on the Oil Record Book Parts 1 and 2

ShipRight Notice 1A for

Title: Identification: Revision: GUIDANCE FOR THE RECORDING OF OPERATIONS IN THE OIL RECORD BOOK, PART I

dfdf 34.5 kv and 69 kv, Type O Plus C II Condenser Bushings Technical Guide

Transcription:

Cargo Handling Sheet Caradol SC 48-08 Document date: 4 June 2014

Product Details: Product Name: Caradol SC 48-08 Shipping Name: Chemical Family: Product Code: SDS: Glycerol Propoxylated and Ethoxylated Polyol U311L http://www.shell.com/chemicals/responsible-energy/msds-search.html Physical Properties: Density: 1019 kg/m3 @ 20 deg C. Dynamic Viscosity: 760 (mpa) @ 20 deg C. 270 290 (mpa) @ 40 deg C. Vapor Pressure: Boiling Point: Melting Point: Data Flash Point: >200 deg C. Transshipments Prior to arranging a transhipment, the Shell Chemical Charterer must be in agreement as to the Owner s proposed plan. Marpol Details: Marpol Annex: II IMO Ship Type: 3 Shell Chemicals requires a ship type 2 IMO Pollution Category: Oil Like: High Viscosity: Solidifying: USCG: Z USCG group 40. t compatible with group 12 Isocyanates 2

Cargo Handling Criteria: Prepurging of Vessel s Tanks: N2 Blanket Required: Percent Oxygen in Nitrogen Blanket: Vapor Space Purge: Yes <5% See Regional requirements Loading Temperature Range: Ambient 40 deg C. Transit Temperature Range: 40 45 deg C. (International) Ambient 45 deg C. (EU Barges) Discharge Temperature Range: 40 50 deg C. (Internatiional) Maximum Heating Coil Temperature: < 90 deg C. Adjacent Maximum Cargo Temperature: 50 deg C. Ambient 50 deg C. (EU Barges) Regional Requirements: See notes tes: For voyages between Amsterdam, Rotterdam, Antwerp, and the UK, no nitrogen blanket required. tes: For barge voyages in Europe Stainless steel required. tes: Inter Europe and UK, no wall wash required. tes: International vessels presenting coated tanks, contact Chemicals MTA. tes: EU barges with prior cargo SC 48-08 can be loaded without cleaning. tes: If Nitrogen blanket is in place and Carrier chooses to transship, carrier must reapply nitrogen blanket on the cargo, both on the discharging and receiving ship, at their time, risk, and expense. 3

Tank Acceptance Requirements: All shore and ship cargo lines and tanks are to be presented clean (residual free), dry, odor free, and rust free, with good gaskets and pressure tested heating coils. Stainless Steel or Coated Tanks : Wall Wash Required: Coated, carrier to verify suitability of coating. for product. See also Regional Requirements notes. Yes for International, see also Regional Requirement notes Wash Specifications: Water Misc. pass Chlorides Max 5ppm Odor residual Permanganate >30 minutes Color max 5 Acidity 0.05 mgkoh/g max. Appearance Clear Maintenance of heating coils is to be verified in the ship s log. If product is to be heated, heating coils are to be confirmed leak free. If product is not heated, heating coils are to be drained, dried and blanked off. Sample testing and Product release/ Acceptance Requirements. Loading: Shore tank approved by location based on local process. Manifold samples tested in the field for appearance only. Product release based on local process. Discharge: Product acceptance based on key tests on arrival samples form each tank based on local process. 4

Safety Information and Incident Reporting. Safety Information: For more detailed information, refer to the SDS or e-sds for reportable spill/release quantities whether in the water, air or ground. Incident Reporting: International Registered Vessels:- If an incident occurs call Shell International Trading and Shipping in London on (44) 207-934-7777. Jones Act Vessels:- If an incident occurs, call the Shell 24 hr. incident number at 713-241-2532. For additional marine cargo handling advice or information, contact Captain Eddie Trotter at (+1 713 241 3535) Shell Chemical LP PO Box 4407 Houston Texas 77210 USA Tel +1 866 897 4355 Internet http://www.shell.com/chemicals Disclaimer The information contained in this publication is, to the best of our knowledge, true and accurate, but any recommendations or suggestions that may be made are without guarantee, since the conditions of use are beyond our control. Furthermore, nothing contained herein shall be construed as a recommendation to use any product in conflict with existing patents covering any material or its use. Shell Chemicals The expression Shell Chemicals refers to the companies of the Shell Group of companies that are engaged in the chemical businesses. Each of the companies that make up the Shell Group of companies is an independent entity and has its own separate identity. 5