Hydraulic Related Products Air-Hydro Booster

Similar documents
Hydraulic Related Equipment Air-Hydro Booster

Standard Specifications. Fluid Standard specifications. VH600 Ambient and fluid temperature Operating angle Lubrication. Optional Specifications

Specifications VH600. Ambient temperature and operating fluid temperature Operating angle Lubrication

Impulse Lubricator. Standard Specifications

Specifications VH600. Ambient temperature and operating fluid temperature. Operating angle Lubrication. Semi-standard

Compact Proportional Solenoid Valve

Series VP4 50/4 70. Large Size 5 Port Solenoid Valve Rubber Seal SJ SY SY SV SYJ SZ VF VP4 S0700 VQ VQ4 VQ5 VQC VQC4 VQZ SQ VFS VFR VQ7 VP4

Transmitters: Relay Valve VR4151/4152

PNEUMATIC BOOSTER HIROTAKA MFG. CO.,LTD.

Series SYA3000/5000/7000

Miniature Regulator Series ARJ310

2 Port Valve For Compressed Air and Air-hydro Circuit Control. Exclusively for air pressure system and air-hydro circuit control

Specifications VH600. Ambient temperature and operating fluid temperature Operating angle Lubrication. 3 (Closed center) 3/4, 1 3 (Exhaust center)

Circuit of directional control valve and regulator. Simplifying circuit design. Space saving and piping. work eliminated. Automating pressure control

1 Pneumatics. Transmitters VR4151 VR4152 VR1210 VR1220 VR1210F VR1220F VR1211F VR VR3200 VR3201 VR3100 VR3110

Exclusively for air pressure system and air-hydro circuit control

3 Port Solenoid Valve Direct Operated Poppet Type 02 1 G VT325. For manifold: Enter VO. Valve option. Nil Standard V For vacuum Option.

Series SYA3000/5000/7000

Specifications. Construction. Component Parts No. 1. Description. Body. Knob. Cover Cam ring Stem Spring guide Spring Seal O-ring Valve Cassette

VCHR Series. Direct Operated Regulator for 6.0 MPa (Relieving Type) Service life: 10 million cycles. How to Order

Transmitters: Relay Valve

HFP Series. Specifications. Switch specifications. Wide parallel hand Double acting. Operational stroke length: 20, 30, 40, 60mm.

Speed Controller with Uni One-touch Fitting Push-lock type. New-stand male threads for piping that reduces the screw-in time by 1/3. Model.

Specifications Fluid. Basic Roller lever. Mechanical operation. One way roller lever. Roller plunger. Push button (Flush) Manual operation

Power Valve: Regulator Valve. Specifications. Model VEX Operation type Fluid Max. operating pressure Set pressure Air operated.

Standard Specifications. Model. Port (Bypass lubrication adapter)

Compressed air to

Series VCHR. Direct Operated Regulator for 6.0 MPa (Relieving Type) Service life: 10 million cycles. How to Order

Soft Start-up Valve. AV2000/3000/4000/5000 Series

Specifications VH600. Ambient temperature and operating fluid temperature Operating angle Lubrication. Semi-standard

Standard Specifications. Model. Port (Bypass lubrication adapter)

Rotary Actuators Precautions 1 Be sure to read this before handling.

3 Port Solenoid Valve Pilot Operated Poppet Type. External pilot

PNEUMATIC POWER CYLINDER

Air-hydro Converter CCT Series. Application Example. Multipoint intermediate stops

Two Hand Control Valve

Specifications VH600. Ambient temperature and operating fluid temperature Operating angle Lubrication. Semi-standard

Lateral parallel hand Double acting. Operational stroke length: 20, 30, 40mm. 980m/s2

Power Valve: Economy Valve. Standard Specifications. Model VEX55-04

3 Port Air Operated Valve VTA. Indicate VO for manifold. Port size. Nil 02 1/4. Specifications Fluid. Option Description Bracket (With screw)

PNEUMATIC POWER CYLINDER

Specifications Valve. Construction. Component Parts No. 1. Description. Body. Knob. Cover Cam ring Stem Spring guide Spring Seal O-ring Valve Cassette

Body width of 10mm, Nl/min (49.08) 2W (Standard) Nl/min (78.52) 4W (U type: Large flow) Vacuum applications possible (up to 100kPa) 3 S.

Circuit of directional control valve and regulator. Simplifying circuit design. Space saving and piping. work eliminated. Automating pressure control

3 Port Solenoid Valve Direct Operated Poppet Type

Electro-pneumatic Proportional Valve. Specifications. Model Flow type Pressure type VEF2121

Series VP3145/3165/3185

Miniature Regulator. Standard Specifications. Model IN side OUT side (Applicable tubing O.D.) Proof pressure Maximum operating pressure

L1000/L3000/L4000/L8000-W Series

Speed Controller with One-touch Fitting

Frame Clamp Cylinder WRF100. Positioning dowel pin holes for jig

0.45 ms. 9mm. High Speed 2 Port Valve. SX10 Series. 2 mounting types

Indicate VO for manifold. Port size. Nil 1/8 02 1/4. Specifications. Option Description Bracket (With screw) Part no. DXT060-27A

CM2X-Z 10 - C D M 2 X L Z - M9BW. Port thread type. Nil TN TF. Rc NPT. Rubber bumper only. Cylinder stroke (mm) Action

ITVX Series. Stepless control of air pressure proportional to an electrical signal. Supply pressure: 5.0 MPa

Clean Regulator. SRH Series. Contamination controlled stainless steel regulator ARJ

5 Port Solenoid Valve Direct Operated Poppet Type. Specifications

Series ITV0000. Compact Electro-Pneumatic Regulator ITV N Q. IITV00 02 n. How to Order. For single unit and single unit for manifold

ALB900 Series. Standard Specifications. Model. Port (Bypass lubrication adapter)

Low Torque Rotary Joint

Coolant Valve. Series VNC. Cylinder actuation by pilot air. Wide selection of port size and variations

Vacuum applications possible (up to 100kPa) Base mounted. Cylinder bore size (mm) Series CM2. Pressure: 0.5MPa Load ratio: 50% Cylinder stroke: 300mm

Specifications Fluid. 5 to 60 C (No freezing) Effective area. Basic Roller lever. Mechanical operation. One way roller lever.

Standard Specifications Model. How to Order. Mist spray unit. Recommended Equipment. Mixing valve

Series AV2000/3000/4000/5000

Usable in stopper applications in conveyor lines without an air source! Features

INSTRUCTION OIL PUMP. SH-110A5 MODEL No DR-110A5 MODEL No PD-110A5 MODEL No WARNING

Process Valve/Series VN The cylinder operation by external pilot air Can be operated with pressure differential zero.

Oil/Air Lubrication Systems for Steel Production Facilities

G1/8-3/2-Way Valves - Series K9

Coolant Valve. Air Operated/External Pilot Solenoid

ACTUATORS GENERAL CATALOG

5 Port Pilot Operated Solenoid Valve Rubber Seal, Plug-in/Non Plug-in. Standard Specifications. Fluid Operating pressure range

2/3 Port Mechanical Valve. Specifications Fluid Operating pressure Ambient and fluid temperature Effective area Lubrication Port size Mass (Basic)

OPERATION MANUAL. Diaphragm Pump. TD/TD2 Series TD-08, 15, 20/TD2-25. Introduction

Low Torque Rotary Joint

Micro Mist Separator. Model. Note) 1 8, , , , , 1. Model/Free Standing Type. Model AMD (2B)JIS 10K FF flange

Free position locking flat and compact cylinder UFCD Series

BUTTERFLY VALVE POWER-PACK CONTROLLED BUTTERFLY VALVE

Series SYA3000/5000/7000

Piping labor reduced A flexible system has been adopted. E-P HYREG. Cylinder behavior and pressurization control. Example

3 Port Solenoid Valve Direct Operated Poppet Type. Body type. Body ported. Manifold. Valve option

Air Valve AIR-PILOTED VALVES

Specifications. Model/Rated Flow Rate. Accessory/Option. Differential pressure indicator

HBL Series. Specifications. Switch specifications. Fulcrum hand Double acting/single acting. Open and close angle: -5 to 20. Descriptions 2CS 20 1C 15

Direct Operated 3-port solenoid valve

Type 3273 Hand-operated Actuator Type 3273 Side-mounted Handwheel

Series SYA3000/5000/7000

Process Valve. 2 Port Valve For Compressed Air and Air-hydro Circuit Control

Syslog Technologies Innovative Thoughts

Power Valve: Regulator Valve. Specifications. Model VEX Operation type Fluid Max. operating pressure Set pressure Air operated.

INSTRUCTION GREASE PUMP. PD110A50T MODEL No PD110A50T-SL MODEL No PD110A50 MODEL No DR110A50 MODEL No.

Guide Table. MGF Series

NAMUR Interface 5 Port Solenoid Valve

Operation Manual For KITZ B Series Pneumatic Valve Actuators

CLARKSON URETHANE KNIFE GATE VALVES FIGURE SU10R

Pressure Control Equipment

25% reduction in volume * PB1013A/Air-operated type without foot

Guide Table. ø40, ø63, ø100

Flow characteristics Max. (1) b Standard Specifications. P Manual override.

Transcription:

Hydraulic Air-Hydro Booster Made to Order Converts air pressure to hydraulic pressure for high pressure hydraulic cylinder actuation. Generates 3.5 to 14 MPa hydraulic pressure with 0.5 MPa air pressure. No hydraulic pump is required. High hydraulic pressure can easily be obtained. Hydraulic pressure can be steplessly controlled by only adjusting the air pressure using the regulator. There is no trouble due to temperature rise even under the condition of continuous pressurization. You can select from two types of pressurization methods (direct type and pre-load type) according to the application. Applications For lifting work pieces For automatic clamping devices Hydraulic pressure source for low profile hydraulic cylinders Pressurization Methods There are two types of air-hydro boosters: direct type and pre-load type. 1 Direct Type This is suitable when high power is required over the entire stroke, such as moving a work piece in a short distance. Air-hydro booster Hydraulic cylinder Conveying work Operating direction W High pressure operation 2 Pre-load Type This is suitable when pressurizing a work piece after moving it in position using a hydraulic cylinder. The pre-load type requires an air-hydro converter (Series CCT). Air-hydro converter (Series CCT) Press fitting work Operating direction Air-hydro booster Hydraulic cylinder First process (low-pressure operation) Second process (high-pressure operation) 425

Hydraulic / Air-Hydro Booster Specifications Part number CQ2L160- CQ2L160- CQ2L0- CQ2L140- DCG5643G-17 DCG56G-1 Z4-60 DCG5645G-17 Air pressure cylinder diameter Pressure increase ratio Amount of discharged oil 1 : 7 17 cm 3 1 : 1 cm 3 ø0 1 : 13 60 cm 3 ø140 1 : 17 cm 3 Maximum working pressure 1.0 MPa (air pressure) Generated hydraulic pressure 3.5 MPa 5.0 MPa 6.5 MPa 7.5 MPa (with 0.5 MPa air pressure) Fluid Air pressure Air Hydraulic pressure Turbine oil class 1 (ISO VG32) Ambient and fluid temperature 5 to 60 C With oil pot With oil pot With oil pot With oil pot The value when the maximum working pressure of 0.43 MPa is applied. CQ2F0- Z4-60 ø0 1 : 16 60 cm 3 0.87 MPa 8.0 MPa Without oil pot CQ2LH160- DCG864AG-5 1 : 25 5 cm 3 0.56 MPa 12.5 MPa Without oil pot CQ2LH160-20-DCI145I 1 : 32.6 20 cm 3 0.43 MPa 14 MPa With oil pot CQ2L160-DCG5643G-17 (pressure increase ratio: 1 to 7) / Wall mount type 1.5 1 213.5 ø136 Approx. 8 37.5 8 82.5 20 143.5 16 270.5 CQ2L160-DCG56G-1 (pressure increase ratio: 1 to ) / Wall mount type 1.5 5 243.5 ø126 Approx.188 37.5 ø84 Rc1/2 8 46 61 77.5 173.5 16 32.5 426

Hydraulic / Air-Hydro Booster CQ2LH160-DCG864AG-5 (pressure increase ratio: 1 to 25) / Horizontal mount type 1.5 ø0 Rc 1 CQ2L0-Z4-60 (pressure increase ratio: 1 to 13) / Wall mount type 260 82.5 35 5.5 ø57 ø62 6.5 141.5 42 0.5 73 21 Approx. 4 65 513.5 332 Rc1/2 (Oil supply port) 262 71 21 137 162 16 7 4 x ø13 20 11 13 2.5 136.5 ø6 66 117 6 375.5 CQ2L140-DCG5645G-17 (pressure increase ratio: 1 to ) / Wall mount type 1 1 1.5 24.5 8 ø120 Approx. 178 38.5 204 47.5 86 8 76.5 26 122.5 47.5 14 248.5 427

Hydraulic / Air-Hydro Booster CQ2F0-Z4-60 (pressure increase ratio: 1 to 16) / Horizontal mount type 6.5 4 x ø11 1 5 11 Rc 1/4 (Oil supply port) 117 4 ø57 4 117 136 4 3.5 83.5 412.5 225.5 CQ2LH160-20-DCI145I (pressure increase ratio: 1 to 32.6) / Horizontal mount type 67.5 13 Approx. 1 56.5 42.5 Rc 1/8 Rc 3/8 ø0 ø52 4 x ø1 through 2.5 136 1 180 22 53 51.5 2 343 53 22 Special order products other than those listed here are available. Please contact SMC for details. Product Specific Precautions Be sure to read this before handling the. Refer to back page 50 for Safety Instructions and pages to 221 for Hydraulic Cylinders and Auto Switches Precautions. 1. The hydraulic fluid in the oil pot or the air-hydro converter of the air-hydro booster (hereafter referred to as "the booster") may become black and cloudy. This is caused by the mixing in of powder from the initial abrasion of the seals in the booster (minimal abrasion that does not affect the performance of the seals), and a phenomenon that cannot be avoided. The performance of the booster is not compromised with the hydraulic fluid black and cloudy. Caution 1. The oil level in the oil pot and the air-hydro converter may become higher than the initial level when the booster is stopped for a long period of time after a long period of operation. This is caused because air is accumulated in the piping between the booster and the hydraulic cylinder and the volume of the entire piping is increased. In this case, please release the air from the hydraulic piping. Otherwise, oil may spout from the breathing hole of the oil supply plug when the booster is started. Caution 2. It is recommended that the booster is installed in a location higher than that of the hydraulic cylinder. If it is necessary to install the booster in a location lower than that of the hydraulic cylinder, or if you install piping with many bends, install an air release valve at the uppermost location in the piping. Then, please release the air periodically. 3. If your air-hydro booster is one with an oil pot, the oil supply plug of the oil pot has a breathing hole and oil may leak from the hole depending on the mounting orientation. If such oil leakage is assumed due to the mounting orientation of the air-hydro booster, reconnect the oil pot using a pipe or fitting so that the oil pot is vertical and facing up. Then, please release the air periodically. 428

Hydraulic Air-Hydro Unit CC Refer to Best Pneumatics No. 2-1 for details. Air-hydro unit Converter Type Air-hydro unit Converter Valve unit Features Series Nominal diameter (mm) CC 63, 0, 160 CCT 40, 63, 0, 160 CCV By converting air pressure into hydraulic pressure, functions that are the same as those of a hydraulic unit can be obtained while using pneumatic equipment. 42