AMERICAN COATINGS. Systems Guide

Similar documents
TUFCOTE 3.3 PR HIGH SOLIDS FAST DRY ALKYD PRIMER (formerly DuPont 681 FD )

935-Series. NORTHSTAR MS, HG Urethane Topcoat. Description:

SMART TRUCK BED LINER - BLACK

TUFCOTE 1.9 HG-D HIGH GLOSS WATERBORNE ACRYLIC DTM (formerly DuPont 72P )

SMART TRUCK BED LINER - TINTABLE

Surface Preparation and Application of Ronass Pipe Shield 1319

PRODUCT GUIDE: UNIVERSAL PRIMERS. Version:

UK PG 6/23(92) Appendix 3: max g/l (approx. 3.6 lb/us gal) 5.7 m²/l for 100 µm (229 ft²/us gal for 4.0 mils)

Rust Bullet Automotive FAQ s

As a high performance anti-graffiti clear-coat or top-coat, as needed over any properly substrate where:

SIGMAZINC 102 HS. PRODUCT DATA SHEET December 15, 2014 (Revision of December 1, 2012) DESCRIPTION

MARINE SYSTEMS FOR DECKS SYSTEM. a six page issue January 2010 revision of May Application areas: all decks on ships, interior and exterior

PRODUCT DATA SHEET SP-1386

Company Name Number for Support

SECTION FIRE HYDRANTS WITH HYDRANT LOCKS

SIGMAPRIME 700. PRODUCT DATA SHEET December 13, 2014 (Revision of March 1, 2014) DESCRIPTION

SIGMAZINC 109. PRODUCT DATA SHEET January 16, 2015 (Revision of January 5, 2015) DESCRIPTION. Two-component, zinc-rich, polyamide-cured epoxy primer

NAVSEA REVIEWED ASTM F-718. Intershield 300HS, High-Solids Abrasion- Resistant Aluminum Pure Epoxy Anticorrosive

NAVSEA REVIEWED ASTM F-718. Part A: MS-200 / MS209R D. Gray / MS207R Green / MS205R Red / MS201R White / MS203R Yellow / MS218H Part B

NAVSEA REVIEWED ASTM F-718. Part A: 600D02 (Gray); 600D30 (Light Gray); and 600T04 (Buff) Part B: 610C02

Imron 3.5 HG-C High Gloss Polyurethane Clear

OEM APPROVED AND USED

NAVSEA REVIEWED ASTM F-718. If this product is to be applied as part of a coating system, all components of the system must be as listed on the QPL.

CARE & PREVENTIVE MAINTENANCE GUIDE

CORROSION PROTECTION CORROSION PROTECTION FEATURING RUST MORT RUST SEAL RUST TRAP RUST SHIELD RUST PREVENTER CAVITY WAX UNDERCOATINGS COMPARISON CHART

NAVSEA REVIEWED ASTM F-718. If this product is to be applied as part of a coating system, all components of the system must be as listed on the QPL.

SIGMAZINC 68 SP / AMERCOAT 68 SP

PPG Tank Linings. Tank Storage Solutions Guide

Award (Y / N) Reason UOM Supplier Qty Price

(a) Short-term storage of tubeless wheel assemblies may be stored with the wheel o- ring packing installed between the two halves.

Product Catalog A spectrum of refinishing products with proven performance

Frequently Asked Questions for Automotive Applications

PERFORMALOC 9000 Advanced Productivity Coatings from PPG

Application Guide. ATL composites Pty Ltd Tel (+61) Fax (+61)

NAVSEA REVIEWED ASTM F-718. Chesterton ARC 855N, Ceramic Filled Epoxy Coating

CP01S Corrosion Protection

Directive 1999/13/EC, SED: max g/kg max g/l (approx. 2.6 lb/us gal) 6.6 m²/l for 100 µm (265 ft²/us gal for 4.

Saffo Beats Schedule on Barefoot Landing Swing Bridge

Surface Type System Primer Coating (# of coats)

UK PG 6/23(92) Appendix 3: max g/l (approx. 1.7 lb/us gal) 7.2 m²/l for 125 µm (289 ft²/us gal for 5.0 mils)

AMERSHIELD. PRODUCT DATA SHEET April 16, 2018 (Revision of February 3, 2016) DESCRIPTION

NAVSEA REVIEWED ASTM F-718. Part A: B62L230 OAP Blue, B62W230 White, B62RW230 Red Oxide, B62AW230 Haze Gray

NAVSEA REVIEWED ASTM F-718. Part A: B62W210, B62AW210, B62BW210, B62GV210, B62AV210, B62V210

SIGMAPRIME 200 SERIES

ROAD WORTHY SHOP TESTED OEM APPROVED

SIGMAZINC 105. PRODUCT DATA SHEET December 15, 2014 (Revision of July 1, 2013) DESCRIPTION. Two-component, zinc epoxy primer PRINCIPAL CHARACTERISTICS

Universal Primer and Surface Preparation Process

SIGMACOVER 805. PRODUCT DATA SHEET December 12, 2014 (Revision of April 1, 2013) DESCRIPTION

POR-15 Kits. Super Starter Kits $22.99

Technical Support Guide for High Performance Coatings Carboline Company

Surface Type System Primer Coating (# of coats)

NAVSEA REVIEWED ASTM F-718. If this product is to be applied as part of a coating system, all components of the system must be as listed on the QPL.

Tank Armor ADVANCED LINING PROTECTION

Imron 3.4 HG-C High Gloss Polyurethane Clear

P HS EXPRESS CLEARCOAT

METAL BLACKENING SYSTEM

NAVSEA REVIEWED ASTM F-718. SeaVoyage Copper Free Antifoulant; N51R301 Red, N51B301 Black, N51L301 Blue

WELCOME. Give us a call.

PDS N5.2.1 March AQUABASE Plus Engine Bay Color System PRODUCT DESCRIPTION

Boat Hull, Propeller and Top-Side Protection

SIGMACOVER 350. PRODUCT DATA SHEET December 12, 2014 (Revision of June 1, 2014) DESCRIPTION

7 REASONS TO CHOOSE RAPTOR

NAVSEA REVIEWED ASTM F-718. MS-440G LR, Low Radar Signature Epoxy Nonskid Deck Coating

Desoprime CF/CA7502E Chrome-Free Epoxy Primer

NAVSEA REVIEWED ASTM F-718. If this product is to be applied as part of a coating system, all components of the system must be as listed on the QPL.

INTERNATIONAL EPOXIES & SEALERS

PRICE PAGES INSTRUCTIONS

AUTOBASE PLUS SOLID, METALLIC AND PEARL COLORS (HP REDUCERS)

Surface Protective Systems

two component high build polyamine adduct cured coaltar epoxy primer/ coating

VOC COmpliant edition. ProductCatalog. low voc & compliant solutions. Photo courtesy of Shutterstock.com

SIGMAGUARD 730. PRODUCT DATA SHEET December 15, 2014 (Revision of December 1, 2012) DESCRIPTION

NAVSEA REVIEWED ASTM F-718. Interbond 998, Two-pack Anticorrosive High Solids Epoxy Deck Primer

NOVAGUARD 810. PRODUCT DATA SHEET December 11, 2014 (Revision of April 1, 2014) DESCRIPTION

ELIN CARC&WATER NSN MIL SPEC ITEM NAME MIL-DTL-64159

SECTION 6 5 SERVICE PROCEDURES AND SPECIFICATIONS. Body

Style 234 Restrained Flexible Single-Gasket Coupling. System No. Submitted By Spec Sect Para Location Date Approved Date

Our railcar product line includes linings for tank cars serving a range of specialized purposes.

Coating over Metal Roof: 10-Year System

Gel Coat Cup Gun 120-A

NAVSEA REVIEWED ASTM F-718. Part B: B62V260 (standard hardener), B62V265 (OAP hardener)

CLEANERS AND DEGREASERS LUBRICANTS

NOVAGUARD 840. PRODUCT DATA SHEET January 21, 2015 (Revision of December 12, 2014) DESCRIPTION

SECTION 6 5 SERVICE PROCEDURES AND SPECIFICATIONS. Body

Extending Infrastructure Life Using FEVE Bridge Coatings

Imron 2.1 HG-C High Gloss Polyurethane Clearcoat

PPI NBR: H-B (REV 01) DATE: November 30, 2010

NAVSEA REVIEWED ASTM F-718. Dura-Plate - B62H210, B62L210, B62V210 (optically active pigment)

Quality Products Since 1948

HEMPAXANE CLASSIC 55000

Tapecoat. Application Guideline

NOVAGUARD 890. PRODUCT DATA SHEET January 21, 2015 (Revision of December 12, 2014) DESCRIPTION

10P20-44 High Solids Epoxy Primer

Spray Equipment for Every Purpose Industrial Selection Guide

... A Stronger System Than Glass!

Interspec. Technical Specification. Scripps Institute of Oceanography. Melville. California- San Francisco, U.S.A. 19-Nov-2013.

Standards Manager Web Standards List IPS-Iranian Petroleum Standard

Technical Data Sheet. Humidur ME Product Description. Manufacturer s Information

PRODUCT AND COLOUR GUIDE

(Autobase Plus Metallic) 1x1 Increase distance and apply a metallic orientation coat if necessary.

Transcription:

AMERICAN COATINGS Systems Guide www.americancoatings.com

AMERICAN COATINGS MISSION STATEMENT American Coatings is a can do company manufacturing and developing new products to enhance your effectiveness in meeting and exceeding the competition. We take pride in providing value added service, and giving you a product that fits and lasts.

Top-Coat Finishing Options... Page 2 Primer Options... Page 3 Support Materials for Custom Applications... Page 4 Index to Coating Systems... Page 5, 6 CONTENTS Tank and Vessel Restoration... Page 7 Light Industrial Atmosphere... Page 8 Mild Corrosive Areas and Inland to 150 Miles... Page 9 Heavy Corrosive Areas - Acid, Alkaline, and Sea Coasts to 50 Miles Inland... Page 10 Miscellaneous... Page 11 Coating System Specifications... Page 12-46 NOTES 1. Rust-Lok products have extended recoatability and can be used for preconstruction priming as well as inorganic zinc. 2. American Coatings polyurethanes are available with a variety of properties and VOC s. All polyurethane products can be used in these specifications not just the SU Series. 3. American Coatings Inorganic and Epoxy Zincs are available in various VOC contents and zinc loads. See your representative. 4. American Coatings AK Alkyd Primers and Finishes are available in varying solvent systems, VOC s, and with different drying properties. 5. American Coatings AE products can be catalyzed for enhanced performance. 1

PRODUCT OFFERINGS Top-Coat Finishing Options Alkyd Air Dry/Quick Dry AK 4000 Series For brush and roll application. AK 6000 Series Fast dry, high gloss topcoats and primers. AK 7000 Series Slow dry for maximum substrate penetration. Brush & spray. SAK Silicone Silicone modified adding durability and gloss. Acrylic Modified AE Series Improved durability and gloss over alkyds. AC Series Maximum hardness in one component system. Polyurethane Options PU Series Aliphatic Polyurethane offering quality at low cost. SU Series Aliphatic Polyurethane offering excellent gloss and DOI. AU Series Acrylic Polyurethane offering Auto gloss & DOI. 2U Series Superior gloss, DOI, & Mar resistance w / 2.2 VOC. High Heat SC Series Silicone Acrylic with protection to 500 F. SL Series Silicone with protection approaching 1200 F Water Options AW Series Alkyd Water Reducible Primer, and High Gloss Finishes. WB Series Latex Water Acrylic Primer, and Finishes. HW Series Modified Alkyd Modified w/high Gloss & Quick Dry acrylic Acrylic Latex WBR Series Roof Mastics designed for sheet metal, and built-up roofs. Baking BW Series Custom Water Alkyd Baking Enamel. BE Series Custom baking formulations. 2

Primer Options Alkyds AK Shop Coat Series Inexpensive, fast-dry protection. Primarily for spray application. AK Heavy Duty Series For improved durability areas where brushing and spraying is necessary (Tanks, Piping). Alkyd Phenolic AK 3550 Red Oxide Primer that accepts a variety of topcoats. AK 3561 Gray Primer Primer that accepts a variety of topcoats. Epoxy Ester EE 566 Red Oxide Designed for specialty applications. Epoxy Polyamides EX Series Resin Rich Systems for high performance. EM Series High-Build primers for harsh environments. RL Series Designed for use over marginal surfaces or where sandblasting is not permitted. AX Series Automotive quality primer / surfacer. Coal Tar Epoxy EX 8330 Coal Tar Lining, tank bottoms, and sewage treatment applications. Etching Primers AC 12471 One component Acrylic surface prep primer. WP 9521 Two component Vinyl Etch Primer. Zinc and Zinc Modified Primers AZ 11 3.5 VOC Inorganic Zinc. AZ 76 Inorganic Zinc - lower Zinc load then AZ 86. AZ 82 Zinc Rich Epoxy AZ 83 Zinc Rich Epoxy - 2.8 VOC. AZ 84 Liquid Galvanize designed for repair. AZ 86 Maximum load Inorganic Zinc. PRODUCT OFFERINGS 3

PRODUCT OFFERINGS Support Materials for Custom Applications Linings / Caulks / Adhesives EP Glass Flake Tank bottom and shell repair. EP Series Epoxy Phenolic Linings Chem protection for various tanks - frac. Epoxy Novalac Linings Improved chemical resistance. Not for frac tanks. Vinyl Ester Series Liner that handles specialty chemicals CT 1120 One Comp. Coal Tar Gas resistant for buried pipe and tanks BL Series Urethane Bedliners Maximum durability liner, abrasion resistant surface. CL 3 Cable Lock System Self-leveling bolt set coating. CL 8 Black Flexible Epoxy Putty Expansion joints, oil and solvent resistant. CL 10 Gray Epoxy Putty Holes, joints and crack repair - concrete. TL 1 100% Solids Laminating Epoxy Chop fiberglass system for tank repair. TC 7 100% Solids Epoxy Caulk Spray applied for repair - plural. TC 12 Hand applied version of TC 7. Cleaners / Degreasers / Rust Converters RL 101 Rust Converter Converts rust to a black primer. TH 100 Industrial Cleaner Water-based, multiple use cleaner. TH 150 Heavy Duty Degreaser Alkaline cleaner / degreaser. TH 200 Haps Free Degreaser Used where rinsing is impossible TH 950 Chemical Cleaner Acid-based etching of concrete / steel. Floor Coatings (Zero VOC) A two or three coat complete flooring system for concrete finishing. FP 8001 Concrete Primer / Sealer Designed to seal concrete prior to FC application. FC Series Colored Finish Coats Self Leveling Epoxy Coating. FC 8999 Clear Coat Utilized for extreme traffic and wear. Additives Epoxy Accelerators RM 1147 0.5-2.0 ounces per gallon. Urethane Accelerators RM 1014 0.5-1.5 ounces per gallon. Roll Additives Urethane additive for roll application. Urethane Retarder Used to extend pot life. Not all products are stock items. Some products require minimum orders. 4

Index to Coating Systems No. Page 1. Blue, Fiberglass and 100% Solids Epoxy System applied by the American Process...13 2. White, Fiberglass and 100% Solids Epoxy System applied by the American Process...14 3. Vinyl Ester and Fiberglass applied with chopped or mat glass...15 4. 100% Solids Rivet and Seam Caulking applied by the American Process....16 5. Epoxy Zinc and High Build Epoxy Finish...16 6. Epoxy Zinc, Mid Coat High Build Epoxy, and Polyurethane Finish....17 7. Inorganic Zinc, Mid Coat High Build Epoxy, and Polyurethane Finish...17 8. Inorganic Zinc, and High Build Epoxy Finish....18 9. 100 % Solids Epoxy Hand Caulk for Rivets, etc....18 10. Inorganic Zinc, Mid Coat High Build Epoxy, and Epoxy High Gloss Finish....19 11. Heavy Duty Alkyd Primer, and Alkyd Finish Coat...19 12. Epoxy Mastic Primer and High Build Epoxy Finish....20 13. Alkyd Heavy Duty Primer, Alkyd Mid Coat, and Alkyd Finish....20 14. Modified Alkyd All-Purpose Primer, Alkyd Mid Coat, and Alkyd Finish...21 15. Modified Alkyd All-Purpose Primer, Acrylic Mid Coat, and Acrylic Finish....21 16. Modified Alkyd All Purpose Primer, and SU Series Finish...22 17. Modified Alkyd All Purpose Primer, and Epoxy High Build Epoxy Finish....22 18. Modified Alkyd All Purpose Primer, and High Gloss Epoxy Finish....23 19. Zinc Primer for Galvanize Repair....23 20. Epoxy Primer, High Gloss Epoxy Mid Coat, and High Gloss Epoxy Finish...23 21. Epoxy Primer, Polyurethane Mid Coat, and Polyurethane Finish...24 22. Epoxy Primer, and Epoxy Acrylic Finish....24 23. High Build Epoxy Primer, High Gloss Epoxy Mid Coat, and High Gloss Epoxy Finish...25 24. High Build Epoxy DTM (Direct to Metal)....25 25. High Build Epoxy, and Polyurethane Finish....25 26. Rust Lok Epoxy Mastic Primer, and Rust Lok Epoxy Mastic Finish...26 27. Rust Lok Epoxy Mastic Primer, and High Build Epoxy Finish....26 28. Rust Lok Epoxy Mastic Primer, and High Gloss Epoxy....26 29. Rust Lok Epoxy Mastic Primer, and Polyurethane Finish...27 30. Rust Lok Epoxy Mastic Primer, and Alkyd Finish....27 31. Rust Lok Epoxy Mastic Primer, and Acrylic Finish...27 32. Rust Lok Epoxy Mastic Primer, and Epoxy Acrylic Finish...28 33. Rust Lok Gloss Epoxy Mastic Primer, and Rust Lok Gloss Epoxy Mastic Finish....28 34. Rust Lok Gloss Epoxy Mastic Primer, and Epoxy Mastic Finish....28 35. Rust Lok Gloss Epoxy Mastic Primer, and Gloss Epoxy Finish...29 36. High Heat Resistant Epoxy Primer, and High Heat Resistant Epoxy Finish...29 37. 100% Solids Epoxy Rust Lok Primer, Polyurethane Finish...29 38. Vinyl Wash Primer, and High Gloss Epoxy Finish...30 39. Vinyl Wash Primer, and Polyurethane Finish....30 40. Vinyl Wash Primer, and Alkyd Finish....30 41. Vinyl Wash Primer, and Acrylic Finish...31 42. Silicone Acrylic Primer, and Silicone Acrylic Finish....31 43. Silicone Acrylic Zinc Primer, and Silicone Acrylic Finish...31 44. Inorganic Zinc Primer, and Silicone Acrylic Finish...32 45. Silicone Primer, and Silicone Finish...32 46. Silicone Zinc Primer, and Silicone Finish...32 47. Acrylic Latex Block Filler, and Acrylic Latex Finish...33 48. Water Based Alkyd Primer, and Water Based Alkyd Finish....33 49. Latex Roof Coating Primer, and Latex Roof Coating Finish....33 50. Latex Shop Coat Primer, and Latex Finish...34 51. Epoxy Floor System (Thin film)....34 PRODUCT OFFERINGS 5

PRODUCT OFFERINGS Index to Coating Systems No. Page 52. One Component Coal Tar (Oil & Gas Resistant)....35 53. Coal Tar Epoxy Primer, and Coal Tar Epoxy Finish...35 54. Epoxy Phenolic Primer, and Epoxy Phenolic Finish...35 55. Epoxy Flake Filled Phenolic Primer, and Epoxy Flake Filled Phenolic Finish...36 56. Vinyl Ester Flake Filled Primer, and Vinyl Ester Flake Filled Finish....36 57. Epoxy Repair Putty...36 58. Pourable Epoxy Grout....37 59. Reserved...37 60. Epoxy Novaloc Primer, and Epoxy Novaloc Finish....37 61. Flexible Sprayable Epoxy Caulk....38 62. Quick Patch Epoxy Adhesive....38 63. Degreaser/Cleaner (non-etching)...38 64. Chemical Cleaner (etching Type)....38 65. Rust Converter...39 66. Reserved...39 67. DTM Polyurethane...39 68. DTM Alkyd...40 69. Automotive Epoxy Primer, and Polyurethane Finish...40 70. Automotive Epoxy Primer, and Acrylic Finish....40 71. Inorganic Zinc...41 72. FC Series 100% Solids Floor System...41 73. Latex Acrylic...42 74. 100 % Solids Tank Linings (one coat)...42 75. CL 19 100% Solids Cargo Liner...42 76. Flexible Caulk...42 77. Epoxy Automotive Primer, Polyurethane Automotive Top Coat...43 78. Alkyd Spot Primer, Oil Alkyd Mid Coat, and Oil Alkyd Finish....43 79. White Strippable Coating...43 80. Potable Water Epoxy System...44 81. Degreaser, Epoxy Primer, and Polyurethane Finish....44 82. Reserved...44 83. Jet Fuel System (4556D)...45 84. 100% Solids Epoxy Lining (non-laminating)...45 85. Epoxy with Glass Wrap...45 86. Epoxy Primer...46 87. High Build Epoxy Primer...46 88. Chemical Cleaner, Epoxy Primer, and Polyurethane Finish...46 89. Flake Filled Polyester....47 90. Alkyd Finish...47 6

TANK AND VESSEL RESTORATION The American Process is the spray-up application of 100% solids epoxy adhesive resins reinforced with chopped fiberglass applied to steel or masonry surfaces to 62 mils DFT. 1st Choice Alternate System No. System Roofs Underside Corrosion Protection (Floater)... 54 12, 33 Underside Corrosion Protection (Fixed)... 54 12, 33 Top Side - Leaking... 2 37 Painting... 7 6, 20, 23, 25, 29 Patching... 9 57 Shells Interior - Metal Loss by Corrosion and Weather Seal Wear... 1 55, 53 Corrosion Protection... 54 55, 53 Exterior - Rivet and Seam Caulk... 4 9 Painting... 6, 20, 22, 23, 25 27, 29, 31 Bottom Ring (on top of pad)... 76 Bottoms Metal Loss by Corrosion... 1 4 or 9, then 54 or 55 Pitted and Patching... 4 or 9 57 Corrosion Protection - New Tanks, or Replacement Bottoms... 54 55, 53 PRODUCT OFFERINGS 7

PRODUCT OFFERINGS LIGHT INDUSTRIAL ATMOSPHERE 1st Choice System No. Alternate System Structural Steel... 12-15, 68 11, 48, 50 Piping to 180 F... 12-15, 68 11, 48, 50 Piping 180 F to 300 F... 43, 44 42 Piping 300 F to 800 F... 46 45 Stacks and Furnaces to 1000 F... 46 45 Process Equipment to 180 F... 12-15, 68 11, 48, 50 Process Equipment 180 F to 300 F... 43, 44 42 Process Equipment 300 F to 1000 F... 46 45 Vessels, Exterior, to 180 F... 12-15 11, 48, 50 Storage Tanks, Exterior to 180 F... 12-14 48, 50 Carbon Steel to be insulated... 54, 53 12 Carbon Steel Near Cooling Towers... 26, 27 53 Carbon Steel 0 F to 50 F... 54, 55 53 Carbon Steel, Dock Facilities... 26, 27 32, 28 Poured Concrete... 26, 29, 31, 34 50 Concrete Block... 31, 25, 29 50 Masonry (Interior)... 31, 27 50 Concrete Floors... 51 72 Rivet and Sean Caulk, American Process... 4 9 Rivet and Sean Caulk Mastic, Manual... 9 57 Industrial and Equipment Enamels... 13-15 11, 50, 68 Concrete Water Proof and Vapor Seal... 33, 31, 28, 29 47, 49 Urethane Foam Water Proof and Vapor Seal... 49 Wood Water Proof and Vapor Seal... 49 Steel Tank Lining, Chemical Service... 54 23 Weathered Painted Metal Structures to be Painted... 13, 14 11, 48, 50 Overcoating Galvanized Metal... 39-41 50, 48 8

MILD CORROSIVE AREAS AND INLAND TO 150 MILES 1st Choice System No. Alternate System Structural Steel... 12, 24, 26-35 13-18, 48, 50 Piping to 180 F... 12, 24, 26, 27, 13-18, 48, 50 Piping 180 F to 300 F... 43, 44, 71 42 Piping 300 F to 800 F... 46, 71 45 Stacks and Furnaces to 1000 F... 46 45 Process Equipment to 180 F... 12, 24, 26-35 13-18, 48, 50 Process Equipment 180 F to 300 F... 43, 71 44 Process Equipment 300 F to 1000 F... 46 45 Storage Tanks, Exterior to 180 F... 5, 8, 12, 26-36 13-18, 48, 50 Vessels, Exterior to 180 F... 5-8, 10, 11 20-23, 25-37 Carbon Steel to be Insulated... 54, 53 71 Cold Service 0 F to 50 F... 8, 5 42 Carbon Steel Near Cooling Towers... 26, 27 53 Carbon Steel, Dock Facilities... 26, 27 28, 32 Poured Concrete... 26, 29, 31, 34 50 Concrete Block... 31, 25, 29 50 Masonry (Interior)... 31, 27 47 Concrete Floors... 72 51 Rivet and Seam Caulk, American Process... 4 9 Rivet and Seam Caulk, Matstick, Manual... 9 57 Industrial and Equipment Enamels... 13-18 48 Concrete Water Proof and Vapor Seal... 33, 31, 28, 29 48 Urethane Foam Water Proof and Vapor Seal... 49 Wood Water Proof and Vapor Seal... 49 Steel Tank Lining - Chemical Service... 54 Weathered Painted Metal Structures to be Painted... 13, 14 11, 48, 50 Over Coating Galvanized Metal... 39, 40, 41 48, 50 PRODUCT OFFERINGS 9

PRODUCT OFFERINGS HEAVY CORROSIVE AREAS - ACID, ALKALINE, AND SEA COASTS TO 50 MILES INLAND 1st Choice System No. Alternate System Structural Steel... 5-8, 10 20-35, 37 Piping up to180 F... 5-8, 10 20-35, 37 Piping 180 F to 300 F... 43, 44, 71 42 Piping 300 F to 800 F... 46 45 Stacks and Furnaces to 1000 F... 46 45 Process Equipment to 180 F... 5-8, 10 20-37 Process Equipment 180 F to 300 F... 44, 43, 71 42 Process Equipment 300 F to 1000 F... 46 Storage Tank, Exterior, to 180 F... 6, 7 10, 20, 21 Vessels, Exterior, to 180 F... 5-8, 10 20-35, 37 Carbon Steel to be Insulated... 54, 71 53 Cold Service 0 F to 50 F... 8, 5 25, 27-29, 33, 37, 87 Carbon Steel Near Cooling Towers... 20, 23 12 Carbon Steel, Dock Facilities... 5-8, 10 22, 27, 28 Poured Concrete... 26, 29, 31, 34 50 Concrete Block... 31, 25, 29 50 Masonry (Interior)... 50 27 Concrete Floors... 72 51 Rivet and Seam Caulk, American Process... 4 Rivet and Seam Caulk, Manual Application... 9 Industrial and Equipment Enamels... 13, 15, 16 Concrete Water Proof and Vapor Seal... 49 Urethane Foam Water Proof and Vapor Seal... 49 Wood Water Proof and Vapor Seal... 49 Steel Tank Lining - Chemical Service... 54, 55, 56, 60 12 Weathered Painted Metal Structures to be Painted... 18, 26-41 50 Over Coating Galvanized Metal... 38-41 50 10

MISCELLANEOUS 1st Choice Alternate System No. System AUTOMOTIVE Bed Liner... 75 Heavy Duty Haulers... 75 Truck / Auto Painting / Trailers (exterior)... 69 70 Undercoating... 53 52 BARRIERS / OBSTACLES Right of Ways... 90 Fences... 90 Posts... 90 Markers... 90 BUILDINGS Galvanized (slight rust)... 39, 41, 22, 29, 49, 50 32 Galvanized Roof... 49 50 Baked On... 39 50 Baked on Roof... 49 50 Flat Roof... 49 Gutter Lining... 49 CONCRETE Concrete (Oil Soaked)... 88 Concrete Patch... 58 57 CRANES Cranes... 68 67 FIRE TUBE COATING FT Series... 36 54 FLOOR COATINGS FC Series... 72 FRAC TANKS Exterior... 21 29 Interior... 54, 56 84 ISOCYANATE FREE - TWO PART GL Series... 22, 32 JET FUEL LINING Jet Fuel Lining (4556D)... 83 54 MANUFACTURERS STANDARD PAINT Manufactures Stand Paint (overcoating)... 14-18 MARINE Fiberglass Boats... 69 67 Aluminum Boats... 39 41 Steel Boats... 7 6 Barges... 6, 7 34-37 PRODUCT OFFERINGS 11

PRODUCT OFFERINGS MISCELLANEOUS 1st Choice System No. Alternate System MISCELLANEOUS Field Pipe Fence, Corrals... 29 88 Ornamental Iron... 21 11, 13 Galvanized Ornamental Iron... 39, 38 40, 41 PILING Piling New... 53 89 Piling Repairs... 57 PIPE Interior... 86 87 PIPELINE JOINT REPAIR Pipeline Joint Repair... 85 53, 76, 75 POTABLE WATER LINING Potable Water Lining... 80 54 SANDBLASTING Sandblasting not Permitted... 26-37 13 SWIMMING POOLS Swimming Pool Paint... 22, 24 TANKS PRODUCTION (Interior) Old... 1, 56 54 New... 1, 56 54 Bottoms (Buried)... 52 Pipe (Buried)... 52 UNDERWATER EPOXY Underwater Epoxy... 57 VARIOUS METALS Aluminum, Galvanize... 39, 38 40, 41 Stainless... 21 29, 37 Phosphotized... 81 Galvaneal... 88 12

Specification System #1 1 Blue, Fiberglass and 100% Solids Epoxy System applied by the American Process System Solids by Volume: 100% Reactive and Non-Volatile. SSPC-SP5 (Sa3) White Metal Sandblast or NACE No. 1 3-4 mil anchor profile (75 to 100 microns). Primer American Coatings EX 8300 Polyamide Catalyzed Epoxy. Applied to a 1/2-1 mil (12.5-25 microns) DFT Theoretical Coverage: 800 sq. ft. per gallon (19.72 m 2 per liter @ 25 microns) Volume Solids: 50 % Primer is required in large tanks requiring several days sandblasting; EX 8300 must be applied at the end of each day s cleaning operation to prevent overnight rusting. Apply the following caulking and laminating resins direct to the cleaned steel whenever possible. Caulk Rivets and Seams American Coatings TC 7 Epoxy Caulking Resin. Applied to a 62 mils (1550 microns) DFT. Theoretical Coverage: 26 linear feet per gallon (m 2 per liter) Resin and Fiberglass: TL 1 Epoxy Laminating Resin. Apply with chopped fiberglass a 45-50 mils (1125-1250 microns) DFT. Theoretical Coverage: 32 sq. ft. per gallon @ 60 mils (.79 m 2 per liter @ 1,250 microns) Gel Coat: TL 1 Epoxy Resin. Applied to a 12 mils (300 microns) DFT. Theoretical Coverage: 135 sq. ft. per gallon @ 12 mils (3.33 m 2 per liter @ 300 microns) Total System Thickness: 57-62 mils (1425-1550 microns) minimum DFT. Note: For practical coverage of this resin system, contact our office for quantity of materials. For complete specification, patch, and leg detail, see catalog. 13

Specification System #2 2 White, Fiberglass and 100% Solids Epoxy System applied by the American Process System Solids by Volume 100 % Reactive and Non-Volatile. SSPC-SP5 (Sa3) White Metal Sandblast or NACE No. 1 3-4 mil anchor profile (75-100 microns) Primer American Coatings EX 8300 Polyamide Catalyzed Epoxy. Applied to a 1/2-1 mil (12.5-25 microns) DFT Theoretical Coverage: 1 mil 800 sq. ft./gallon @ 1 mil. (19.72 m 2 per liter) Volume Solids: 50 % Primer is required in large tanks requiring several days sandblasting; EX 8300 must be applied at the end of each day s cleaning operation to prevent overnight rusting. Apply the following caulking and laminating resins direct to the cleaned steel whenever possible. Caulk Rivets and Seams: American Coatings TC 7 Epoxy Caulking Resin Applied to a 62 mils (1550 microns) DFT. Theoretical Coverage: 26 lineal feet/gallon @ 62 mils. Resin and Fiberglass: TL 47 Laminating Resin Applied with chopped fiberglass to a 45-50 mils (11250-01250 microns) DFT. Theoretical Coverage: 32 sq. ft./gallon @ 60 mils (.78 m 2 per liter @ 1250 microns) Gel Coat: TL 47 Laminating Resin Applied to a 12 mils (300 microns) DFT. Theoretical Coverage: 135 sq. ft./gallon @ 12 mils (3.33 m 2 per liter @ 300 microns) Total System Thickness: 57-62 mils (1425-1550 microns) DFT. Note: For practical coverage of this resin system, contact our office for quantity of materials. For complete specification see catalog. 14

Specification System #3 3 Vinyl Ester and Fiberglass applied 100% solids with chopped or mat glass Solids by Volume: 100% Reactive and Non-Volatile. : SSPC-SP5 (Sa3) White Metal Sandblast or NACE No. 1 3-4 mil anchor profile (75-100 microns) Primer American Coatings EX 8300 Polyamide Catalyzed Epoxy Iron Oxide Zinc Chromate Applied to a 1/2-1 mil (12.5-25 microns) DFT Theoretical Coverage: 800 sq. ft./gallon @ 1 mil (19.72 m 2 per liter @ 25 microns). Volume Solids: 50 % Primer is required in large tanks requiring several days sandblasting; 1-830 must be applied at the end of each day s cleaning operation to prevent overnight rusting. Apply the following caulking and laminating resins direct to the cleaned steel whenever possible. Caulk Rivets and Seams American Coatings TC 48 Vinyl Ester Caulking Resin Applied t o a 62 mils (1550 microns) DFT - sweep blast before glass application. Theoretical Coverage: 26 lineal feet/gallon @ 62 mils Resin and Fiberglass American Coatings TL 20 Laminating Resin Apply with chopped fiberglass or 1 1/2 oz fiberglass mat to a 45-50 mils (1125-1250 microns) DFT. Theoretical Coverage: 32 sq. ft./gallon @ 50 mils (0.79 m 2 per liter @ 1250 microns). Gel Coat: TL 20 Laminating Resin Applied to a 12 mils (300 microns) DFT. Theoretical Coverage: 135 sq. ft./gallon @ 12 mils (3.33 m 2 per liter @ 300 microns). Total System Thickness: 57-62 mils DFT (1425-1550 microns). Note: Allow 20% to 25% shrinkage factor for each coat of CL 20 Vinyl Ester For practical coverage of this resin system, contact our office for quantity of materials. 15

Specification System #4 4 100% Rivet and Seam Caulking applied by the American Process Solids by Volume: 100% Reactive and Non-Volatile. : SSPC-SP5 (Sa3) White Metal Sandblast or NACE No. 1 3-4 mil anchor profile (75-100 microns) Primer No primer required. Caulk Rivets and Seams American Coatings TC 7 Epoxy Caulking Resin Applied to a 62 mils (1550 microns) DFT Theoretical Coverage: 26 sq. ft. per gallon @ 62 mils. Total System Thickness: 62 mils minimum. (1550 microns) Warranty for Rivet and Seam Caulking Specifications The spray-up method for applying American Coatings TC 7, Catalyzed Epoxy Adhesive, is covered by the American Process Rivet and Seam Caulking Specifications. American Coatings, Tomball, Texas, guarantees only the American TC 7 Epoxy Adhesive to be formulated, manufactured and supplied in accordance with said specifications. The application of American TC 7 to rivets and seams by the American Process Method is the total responsibility of qualified and approved contractors. Guarantees for workmanship and application will be given by the contractor. American Coatings LP does not recommend the following conditions without council and written agreements with a company representative: 1. Tank interior application of American Coatings TC 7 to interior rivets and seams except where top coated with TL 1 system or equal. 2. Application of American Coatings TC 7 to bolted tanks. 3. Overcoating American Coatings TC 7 with inorganic zinc rich primers. 4. Exterior or interior application of American Coatings TC 7 to rivet and seams of riveted tanks with added welded sheets. Also included are converted cone roof riveted tanks to floating roof tanks. Specification System #5 5 Epoxy Zinc and Epoxy Mastic Finish. SSPC-SP6 (Sa2) Commercial Blast Cleaning American Coatings AZ 83 Epoxy Zinc. Apply to a 3-6 mils (75-150 microns) DFT. Theoretical Coverage: 374-187 sq. ft. per gallon (9.20-4.6 m 2 per liter @ 25 microns). Volume Solids: 70 % American Coatings EM Series Finish. Apply to a 4-6 mils (100-150 microns) DFT. Theoretical Coverage: 260-173 sq. ft. per gallon (6.4-4.27 m 2 per liter @ 25 microns). Volume Solids: 65 % Total System Thickness: 7-12 dry mils (175-300 microns). 16

Specification System #6 6 Epoxy Zinc, Mid Coat Epoxy Mastic, and Polyurethane Finish. SSPC-SP6 (Sa2) Commercial Blast Cleaning American Coatings AZ 83 Epoxy Zinc. Applied to a 3-6 mils (75-150 microns) DFT. Theoretical Coverage: 374-187 sq. ft. per gallon (9.2-4.6 m 2 per liter @ 25 microns). Volume Solids: 70 % American Coatings EM Series Intermediate. Applied to a 4-6 mils (100-150 microns) DFT. Theoretical Coverage: 260-173 sq. ft. per gallon (6.4-4.27 m 2 per liter). Volume Solids: 65 % Third Coat American Coatings SU Series Finishes Applied to a 3-5 mils (75-125 microns) DFT. Theoretical Coverage: 331-198 sq. ft. per gallon (8.2-4.9 m 2 per liter). Volume Solids: 59-62 %. Total System Thickness: 10-17 dry mils (250-425 microns) DFT. Specification System #7 7 Inorganic Zinc, Mid Coat Epoxy Mastic, and Polyurethane Finish. SSPC-SP6 (Sa2) Commercial Blast Cleaning American Coatings AZ 76 Epoxy Zinc. Applied to a 2.5-6 mils (62.5-150 microns) DFT. Theoretical Coverage: 436-182 sq. ft. per gallon (10.7-4.5 m 2 per liter). Volume Solids: 68 % American Coatings EM Series Intermediate. Applied to a 4-6 mils (100-150 microns) DFT. Theoretical Coverage: 260-173 sq. ft. per gallon (6.4-4.3 m 2 per liter). Volume Solids: 65 % Third Coat American Coatings SU Series Finishes Applied to a 3-5 mils (75-125 microns) DFT. Theoretical Coverage: 331-198 sq. ft. per gallon (8.2-4.9 m 2 per liter). Volume Solids: 62 % Total System Thickness: 9.5-17 dry mils (237.5-425 microns). 17

Specification System #8 8 Inorganic Zinc and High Build Epoxy Finish. SSPC-SP6 (Sa2) Commercial Blast Cleaning American Coatings AZ 76 Epoxy Zinc. Apply to a 2.5-6 mils (62.5-150 microns) DFT. Theoretical Coverage: 436-182 sq. ft. per gallon (10.7-4.5 m 2 per liter). Volume Solids: 68 % American Coatings EM Series Finish. Apply to a 4-6 mils (100-150 microns) DFT. Theoretical Coverage: 260-173 sq. ft. per gallon (6.4-4.3 m 2 per liter). Volume Solids: 65 % Total System Thickness: 6.5-12 dry mils (162.5-300 microns) DFT. Specification System #9 9 100% Solids Hand Caulk for Rivets, Etc. SSPC-SP5 (Sa3) White Metal Sandblast or NACE 1 Caulk Application American Coatings TC 12 100 % Solids Epoxy Caulk Mixing ratio: 2:1 Applied to a 62 mils (1,550 microns) DFT. Theoretical Coverage: 1604 sq. ft. per gallon @ 1 mil 26 linear ft. per gallon @ 62 mils (1/4 bead) Finish Coat Any American Coatings product with the exception of inorganic zinc. It is necessary to brush blast for enhanced adhesion when topcoating with alkyds. 18

Specification System #10 10 Inorganic Zinc, Mid Coat High Build Epoxy, and Epoxy High Gloss Finish. SSPC-SP6 (Sa2) Commercial Blast Cleaning American Coatings AZ 76 Inorganic Zinc. Applied to a 2.5-6 mils (62.5-150 microns) DFT. Theoretical Coverage: 436-182 sq. ft. per gallon (10.7-4.5 m 2 per liter). Volume Solids: 68 % American Coatings EM Series Intermediate. Applied to a 4-6 mils (100-150 microns) DFT. Theoretical Coverage: 260-173 sq. ft. per gallon (9.2-4.6 m 2 per liter). Volume Solids: 65 % Third Coat American Coatings EX Series Finishes Applied to a 2-3 mils (50-75 microns) DFT. Theoretical Coverage: 489-326 sq. ft. per gallon (12-8 m 2 per liter). Volume Solids: 61 % Total System Thickness: 8.5-15 dry mils (212.5-375 microns) DFT Specification System #11 11 Shop Coat Alkyd Primer, and Alkyd Finish SSPC-SP3 (St3) Power Tool Cleaning SSPC-SP2 (St2) Hand Tool Cleaning American Coatings AK Series Heavy Duty Primer (AK3190 Red or AK3545 Gray) Applied to a 1.5-2.0 mils (37.5-50 microns) DFT. Theoretical Coverage: Varies 1 Volume Solids: Varies 1 American Coatings AK 7000 Series Finish. Applied to a 1.5-2.0 mils (37.5-50 microns) DFT. Theoretical Coverage: 556-417 sq. ft. per gallon (13.7-10.3 m 2 per liter). Volume Solids: 52 % Total System Thickness: 4.5-6 dry mils (100-150 microns) DFT. 1 Varies per product, see data sheet (Tab 2 in catalog) 19

Specification System #12 12 High Build Epoxy Primer and High Build Epoxy Finish SSPC-SP6 (Sa2) Commercial Blast Cleaning Preferred Surfaces should be free of dust, dirt, oils, moisture and contaminates. American Coatings EM Series Epoxy Primer (EM 8301 Red, EM 8442 Gray) Applied to a 4-6 mils (100-150 microns) DFT. Theoretical Coverage: 260-178 sq. ft. per gallon (6.4-4.3 m 2 per liter). Volume Solids: 65 % American Coatings EM Series Epoxy Applied to a 4-6 mils (100-150 microns) DFT. Theoretical Coverage: 260-178 sq. ft. per gallon (6.4-4.3 m 2 per liter). Volume Solids: 65 % Total System Thickness: 8-12 dry mils (200-300 microns) DFT. Specification System #13 13 Alkyd Heavy Duty Primer, Alkyd Mid Coat, and Alkyd Finish. SSPC-SP6 (Sa2) Commercial Blast Cleaning American Coatings AK Series Heavy Duty Primer (AK3190 Red or AK3545 Gray) Applied to a 1.5-2 mils (37.5-50 microns) DFT. Theoretical Coverage: Varies 1 Volume Solids: Varies 1 American Coatings AK 7000 Series Long Oil Finishes Applied to a 1.5-2 mils (37.5-50 microns) DFT. Theoretical Coverage: 556-417 sq. ft. per gallon (13.7-10.3 m 2 per liter). Volume Solids: 52 % Third Coat American Coatings AK 7000 Series Long Oil Finishes Applied to a 1.5-2 mils (37.5-50 microns) DFT. Theoretical Coverage: 556-417 sq. ft. per gallon (13.7-10.3 m 2 per liter). Volume Solids: 52 % Total System Thickness: 4.5-6 dry mils (100-150 microns) DFT. 1 Varies per product, see data sheet (Tab 2 in catalog) 20

Specification System #14 14 Modified Alkyd All Purpose Primer, Alkyd Mid Coat, and Alkyd Finish. SSPC-SP6 (Sa2) Commercial Blast Cleaning SSPC-SP2 (St2) Hand Tool Cleaning American Coatings AK Series All Purpose Primer (AK 3550 Red or AK 3561 Gray) Applied to a 1-1.5 mils (25-37.5 microns) DFT. Theoretical Coverage: 609-406 sq. ft. per gallon (15-10 m 2 per liter). Volume Solids: 38 % American Coatings AK 7000 Series Finishes Applied to a 1.5-2 mils (37.5-50 microns) DFT. Theoretical Coverage: 556-417 sq. ft. per gallon (13.7-10.3 m 2 per liter). Volume Solids: 52 % Third Coat Optional American Coatings AK 7000 Series Finishes Applied to a 1.5-2 mils (37.5-50 microns) DFT. Theoretical Coverage: 556-417 sq. ft. per gallon (13.7-10.3 m 2 per liter). Volume Solids: 52 % Total System Thickness: 4.5-6 dry mils (100-150 microns) DFT. Specification System #15 15 Modified Alkyd All Purpose Primer, Acrylic Mid Coat, and Acrylic Finish. SSPC-SP3 (St3) Power Tool Cleaning SSPC-SP2 (St2) Hand Tool Cleaning American Coatings AK Series All Purpose Primer Applied to a 1-1.5 mils (25-37.5 microns) DFT. Theoretical Coverage: 609-406 sq. ft. per gallon (15-10 m 2 per liter). Volume Solids: 38 % American Coatings AE Series Finishes Applied to a 1.5-2 mils (37.5-50 microns) DFT. Theoretical Coverage: 427-320 sq. ft. per gallon (10.5-7.9 m 2 per liter). Volume Solids: 40 % Third Coat Optional American Coatings AE Series Finishes Applied to a 1.5-2 mils (37.5-50 microns) DFT. Theoretical Coverage: 427-320 sq. ft. per gallon (10.5-7.9 m 2 per liter). Volume Solids: 40 % Total System Thickness: 4-5.5 dry mils (100-137.5 microns) DFT. AE Finishes can be catalyzed for better performance (see your American Coatings Representative). 21

Specification System #16 16 Modified Alkyd All Purpose Primer and SU Series Finish. SSPC-SP3 (St3) Power Tool Cleaning SSPC-SP2 (St2) Hand Tool Cleaning American Coatings AK Series All Purpose Primer Applied to a 1-1.5 mils (25-37.5 microns) DFT. Theoretical Coverage: 609-406 sq. ft. per gallon (15-10 m 2 per liter). Volume Solids: 38 % American Coatings SU Series Finishes 1 Applied to a 3-5 mils (75-100 microns) DFT. Theoretical Coverage: 338-198 sq. ft. per gallon (8.2-4.9 m 2 per liter). Volume Solids: 62 % Total System Thickness: 4-6.5 dry mils (100-137.5 microns) DFT. 1 Low VOC version (2.8 #/gal) PU Series also available Specification System #17 17 Modified Alkyd All Purpose Primer and High Build Epoxy Finish. SSPC-SP3 (St3) Power Tool Cleaning SSPC-SP2 (St2) Hand Tool Cleaning American Coatings AK Series All Purpose Primer Applied to a 1-1.5 mils (25-37.5 microns) DFT. Theoretical Coverage: 609-406 sq. ft. per gallon (15-10 m 2 per liter). Volume Solids: 38 % American Coatings EM Series Finishes Applied to a 4-6 mils (100-150 microns) DFT. Theoretical Coverage: 260-173 sq. ft. per gallon (6.4-4.3 m 2 per liter). Volume Solids: 65 % Total System Thickness: 5-7.5 dry mils (125-187.5 microns) DFT. 22

Specification System #18 18 Modified Alkyd All Purpose Primer, High Gloss Epoxy Mid Coat, and High Gloss Epoxy Finish. SSPC-SP3 (St3) Power Tool Cleaning SSPC-SP2 (St2) Hand Tool Cleaning American Coatings AK Series All Purpose Primer Applied to a 1-1.5 mils (25-37.5 microns) DFT. Theoretical Coverage: 609-406 sq. ft. per gallon (15-10 m 2 per liter). Volume Solids: 38 % American Coatings EX Series Finishes Applied to a 2-3 mils (50-75 microns) DFT. Theoretical Coverage: 489-326 sq. ft. per gallon (12-8 m 2 per liter). Volume Solids: 61 % Third Coat Optional American Coatings EX Series Finishes Applied to a 2-3 mils (50-75 microns) DFT. Theoretical Coverage: 489-326 sq. ft. per gallon (12-8 m 2 per liter). Volume Solids: 61 % Total System Thickness: 5-7.5 dry mils (125-187.5 microns) DFT. Specification System #19 19 Zinc Primer for Galvanize Repair SSPC-SP3 (St3) Power Tool Cleaning SSPC-SP2 (St2) Hand Tool Cleaning American Coatings AZ 84 Liquid Galvanize Applied to a 1-2 mils (25-50 microns) DFT. Theoretical Coverage: 592-296 sq. ft. per gallon (14.5-7.3 m 2 per liter). Volume Solids: 37 % Total System Thickness: 1-2 dry mils (25-50 microns) DFT. When topcoating use American Coatings WB Finishes. Specification System #20 20 Epoxy Primer, High Gloss Epoxy Mid Coat, and High Gloss Epoxy Finish. SSPC-SP6 (Sa2) Commercial Blast Cleaning American Coatings EX Series Primer Applied to a 2-3 mils (50-75 microns) DFT. Theoretical Coverage: 489-326 sq. ft. per gallon (12-8 m 2 per liter). Volume Solids: 61 % American Coatings EX Series Finishes Applied to a 2-3 mils (50-75 microns) DFT. Theoretical Coverage: 489-326 sq. ft. per gallon (12-8 m 2 per liter). Volume Solids: 61 % Third Coat Optional American Coatings EX Series Finishes Applied to a 2-3 mils (50-75 microns) DFT. Theoretical Coverage: 489-326 sq. ft. per gallon (12-8 m 2 per liter). Volume Solids: 61 % Total System Thickness: 6-9 dry mils (150-225 microns) DFT. 23

Specification System #21 21 Epoxy Primer, Polyurethane Mid Coat, and Polyurethane Finish. SSPC-SP6 (Sa2) Commercial Blast Cleaning American Coatings EX Series Primer Applied to a 2-3 mils (50-75 microns) DFT. Theoretical Coverage: 489-326 sq. ft. per gallon (12-8 m 2 per liter). Volume Solids: 61 % American Coatings SU Series Finishes Applied to a 3-5 mils (75-125 microns) DFT. Theoretical Coverage: 322-193 sq. ft. per gallon (7.9-4.7 m 2 per liter). Volume Solids: 59-62 % Third Coat Optional American Coatings SU Series Finishes Applied to a 3-5 mils (75-125 microns) DFT. Theoretical Coverage: 338-198 sq. ft. per gallon (8.2-4.9 m 2 per liter). Volume Solids: 62 % Total System Thickness: 8-13 dry mils (200-325 microns) DFT. Specification System #22 22 Epoxy Primer, and Epoxy Acrylic Finish. SSPC-SP6 (Sa2) Commercial Blast Cleaning American Coatings EX Series Primer Applied to a 2-3 mils (50-75 microns) DFT. Theoretical Coverage: 489-326 sq. ft. per gallon (12-8 m 2 per liter). Volume Solids: 61 % American Coatings GL Series Finishes Applied to a 4-6 mils (100-150 microns) DFT. Theoretical Coverage: Varies 1 Volume Solids: Varies 1 Total System Thickness: 6-9 dry mils (150-225 microns) DFT. 1 Varies per product, see data sheet (Tab 6 in catalog) 24

Specification System #23 23 High Build Epoxy Primer, High Gloss Epoxy Mid Coat, and High Gloss Epoxy Finish. SSPC-SP6 (Sa2) Commercial Blast Cleaning American Coatings EM 8301 Red Epoxy Primer Applied to a 4-6 mils (100-150 microns) DFT. Theoretical Coverage: 260-173 sq. ft. per gallon (6.4-4.3 m 2 per liter). Volume Solids: 65 % American Coatings EX Series Finishes Applied to a 2-3 mils (50-75 microns) DFT. Theoretical Coverage: 489-326 sq. ft. per gallon (12-8 m 2 per liter). Volume Solids: 61% Third Coat Optional American Coatings EX Series Finishes Applied to a 2-3 mils (50-75 microns) DFT. Theoretical Coverage: 489-326 sq. ft. per gallon (12-8 m 2 per liter). Volume Solids: 61 % Total System Thickness: 8-12 dry mils (200-300 microns) DFT. Specification System #24 24 High Build Epoxy DTM SSPC-SP6 (Sa2) Commercial Blast Cleaning American Coatings EM 8301 Red Epoxy Primer Applied to a 4-6 mils (100-150 microns) DFT. Theoretical Coverage: 260-173 sq. ft. per gallon (6.4-4.3 m 2 per liter). Volume Solids: 65 % Total System Thickness: 4-6 dry mils (100-150 microns) DFT. Specification System #25 25 High Build Epoxy, and Polyurethane Finish. SSPC-SP6 (Sa2) Commercial Blast Cleaning American Coatings EM 8301 Red Epoxy Primer Applied to a 4-6 mils (100-150 microns) DFT. Theoretical Coverage: 260-173 sq. ft. per gallon (6.4-4.3 m 2 per liter). Volume Solids: 65 % American Coatings SU Series Finishes Applied to a 3-5 mils (75-125 microns) DFT. Theoretical Coverage: 360-198 sq. ft. per gallon (8.2-4.9 m 2 per liter). Volume Solids: 59-62 %. Total System Thickness: 7-11 dry mils (175-275 microns) DFT. 25

Specification System #26 26 Rust Lok Epoxy Mastic Primer, and Rust Lok Epoxy Mastic Finish. SSPC-SP3 (St3) Power Tool Cleaning SSPC-SP2 (St2) Hand Tool Cleaning American Coatings RL 1464 Marginal Surface Primer/Finishes Applied to a 6-8 mils (150-200 microns) DFT. Theoretical Coverage: 187-140 sq. ft. per gallon (4.6-3.5 m 2 per liter). Volume Solids: 70 % American Coatings RL 1464 Marginal Surface Primer/Finishes Applied to a 6-8 mils (150-200 microns) DFT. Theoretical Coverage: 187-140 sq. ft. per gallon (4.6-3.5 m 2 per liter). Volume Solids: 70 % Total System Thickness: 12-16 dry mils (300-400 microns) DFT. Specification System #27 27 Rust Lok Epoxy Mastic Primer, and High Build Epoxy Finish. SSPC-SP3 (St3) Power Tool Cleaning SSPC-SP2 (St2) Hand Tool Cleaning American Coatings RL 1464 Marginal Surface Primer/Finishes Applied to a 6-8 mils (150-200 microns) DFT. Theoretical Coverage: 187-140 sq. ft. per gallon (4.6-3.5 m 2 per liter). Volume Solids: 70 % American Coatings EM Series Finishes Applied to a 4-6 mils (100-150 microns) DFT. Theoretical Coverage: 260-173 sq. ft. per gallon (6.4-4.3 m 2 per liter). Volume Solids: 65 % Total System Thickness: 10-14 dry mils (250-350 microns) DFT. Specification System #28 28 26 Rust Lok Epoxy Primer, and High Gloss Epoxy SSPC-SP3 (St3) Power Tool Cleaning SSPC-SP2 (St2) Hand Tool Cleaning American Coatings RL 1464 Marginal Surface Primer/Finishes Applied to a 6-8 mils (150-200 microns) DFT. Theoretical Coverage: 187-140 sq. ft. per gallon (4.6-3.5 m 2 per liter). Volume Solids: 70 % American Coatings EX Series Finishes Applied to a 2-3 mils (50-75 microns) DFT. Theoretical Coverage: 489-326 sq. ft. per gallon (12-8 m 2 per liter). Volume Solids: 61 % Total System Thickness: 8-11 dry mils (200-275 microns).

Specification System #29 29 Rust Lok Epoxy Mastic Primer, and Polyurethane Finish SSPC-SP3 (St3) Power Tool Cleaning SSPC-SP2 (St2) Hand Tool Cleaning American Coatings RL 1464 Marginal Surface Primer/Finishes Applied to a 6-8 mils (150-200 microns) DFT. Theoretical Coverage: 187-140 sq. ft. per gallon (4.6-3.5 m 2 per liter). Volume Solids: 70 % American Coatings SU Series Finishes Applied to a 3-5 mils (75-125 microns) DFT. Theoretical Coverage: 338-198 sq. ft. per gallon (8.2-4.9 m 2 per liter). Volume Solids: 59-62 % Total System Thickness: 9-13 dry mils (225-325 microns) DFT. Specification System #30 30 Rust Lok Epoxy Mastic Primer, and Alkyd Finish SSPC-SP3 (St3) Power Tool Cleaning SSPC-SP2 (St2) Hand Tool Cleaning American Coatings RL 1464 Marginal Surface Primer/Finishes Applied to a 6-8 mils (150-200 microns) DFT. Theoretical Coverage: 187-140 sq. ft. per gallon (4.6-3.5 m 2 per liter). Volume Solids: 70 % American Coatings AK 4000 Series Finishes or AK 6000 Series Finishes Only. Applied to a 2-3 mils (150-200 microns) DFT. Theoretical Coverage: Varies 1 Volume Solids: 32-35 % Total System Thickness: 8-10 dry mils (200-250 microns) DFT. Specification System #31 31 Rust Lok Epoxy Mastic Primer, and Acrylic Finish SSPC-SP3 (St3) Power Tool Cleaning SSPC-SP2 (St2) Hand Tool Cleaning American Coatings RL 1464 Marginal Surface Primer/Finishes Applied to a 6-8 mils (150-200 microns) DFT. Theoretical Coverage: 187-140 sq. ft. per gallon (4.6-3.5 m 2 per liter). Volume Solids: 70 % American Coatings AE Series Finishes Applied to a 1.5-2 mils (37.5-50 microns) DFT. Theoretical Coverage: 427-320 sq. ft. per gallon (10.5-7.9 m 2 per liter). Volume Solids: 40 % Total System Thickness: 7.5-10 dry mils (187.5-250 microns) DFT. 27

Specification System #32 32 Rust Lok Epoxy Mastic Primer, and Epoxy Acrylic Finish SSPC-SP3 (St3) Power Tool Cleaning SSPC-SP2 (St2) Hand Tool Cleaning American Coatings RL 1464 Marginal Surface Primer/Finishes Applied to a 6-8 mils (150-200 microns) DFT. Theoretical Coverage: 187-140 sq. ft. per gallon (4.6-3.5 m 2 per liter). Volume Solids: 70 % American Coatings GL Series Finishes Applied to a 4-6 mils (100-150 microns) DFT. Theoretical Coverage: Varies 1 Volume Solids: Varies 1 Total System Thickness: 10-14 dry mils (250-350 microns) DFT. 1 Varies per product, see data sheet (Tab 6 in catalog) Specification System #33 33 Rust Lok Gloss Epoxy Mastic Primer, and Rust Lok Gloss Epoxy Mastic Finish SSPC-SP3 (St3) Power Tool Cleaning SSPC-SP2 (St2) Hand Tool Cleaning American Coatings RL 8000 Marginal Surface Primer/Finishes Applied to a 6-8 mils (150-200 microns) DFT. Theoretical Coverage: 213-160 sq. ft. per gallon (5.2-3.9 m 2 per liter). Volume Solids: 80 % American Coatings RL 8000 Marginal Surface Primer/Finishes Applied to a 6-8 mils (150-200 microns) DFT. Theoretical Coverage: 213-160 sq. ft. per gallon (5.2-3.9 m 2 per liter). Volume Solids: 80 % Total System Thickness: 12-16 dry mils (300-400 microns) DFT. Specification System #34 34 Rust Lok Gloss Epoxy Mastic Primer, and High Build Epoxy Finish SSPC-SP3 (St3) Power Tool Cleaning SSPC-SP2 (St2) Hand Tool Cleaning American Coatings RL 8000 Marginal Surface Primer/Finishes Applied to a 6-8 mils (150-200 microns) DFT. Theoretical Coverage: 213-160 sq. ft. per gallon (5.2-3.9 m 2 per liter). Volume Solids: 80 % American Coatings EM Series Finishes Applied to a 4-6 mils (100-150 microns) DFT. Theoretical Coverage: 260-173 sq. ft. per gallon (6.4-4.3 m 2 per liter). Volume Solids: 65 % Total System Thickness: 10-14 dry mils (250-350 microns) DFT. 28

Specification System #35 35 Rust Lok Gloss Epoxy Mastic Primer, and Gloss Epoxy Finish SSPC-SP3 (St3) Power Tool Cleaning SSPC-SP2 (St2) Hand Tool Cleaning American Coatings RL 8000 Marginal Surface Primer/Finishes Applied to a 6-8 mils (150-200 microns) DFT. Theoretical Coverage: 213-160 sq. ft. per gallon (5.2-3.9 m 2 per liter). Volume Solids: 80 % American Coatings EX Series Finishes Applied to a 2-3 mils (50-75 microns) DFT. Theoretical Coverage: 489-326 sq. ft. per gallon (12-8 m 2 per liter). Volume Solids: 61 % Total System Thickness: 8-11 dry mils (200-275 microns) DFT. Specification System #36 36 High Heat Resistant Epoxy Primer, and High Heat Resistant Epoxy Finish SSPC-SP5 (Sa3) White Metal Sandblast or NACE No. 1 American Coatings FT 13838 Fire Tube Coating Applied to a 4-6 mils (100-150 microns) DFT. Theoretical Coverage: 168-112 sq. ft. per gallon (5.2-3.9 m 2 per liter). Volume Solids: 42 % American Coatings FT 13838 Fire Tube Coating Applied to a 4-6 mils (100-150 microns) DFT. Theoretical Coverage: 168-112 sq. ft. per gallon (5.2-3.9 m 2 per liter). Volume Solids: 42 % Total System Thickness: 8-12 dry mils (200-300 microns) DFT. Specification System #37 37 100 % Solids Epoxy Mastic Primer, and Polyurethane Finish SSPC-SP6 (Sa2) Commerical Blast Cleaning American Coatings RL 9000 Marginal Surface Primer/Finishes Applied to a 10-15 mils (150-200 microns) DFT. Theoretical Coverage: 160-106 sq. ft. per gallon (3.9-2.6 m 2 per liter). American Coatings SU Series Finishes Applied to a 3-5 mils (75-125 microns) DFT. Theoretical Coverage: 331-198 sq. ft. per gallon (8.2-4.9 m 2 per liter). Volume Solids: 62 % Total System Thickness: 13-20 dry mils (325-500 microns) DFT. 29

Specification System #38 38 Vinyl Wash Primer, and High Gloss Epoxy Finish Properly Cleaned Galvanized Metal or Aluminum American Coatings WP 9521 Vinyl Wash Primer Applied to a 0.2-0.5 mils (5-12.5 microns) DFT. Theoretical Coverage: 401-160 sq. ft. per gallon (9.9-3.9 m 2 per liter). Volume Solids: 5 % American Coatings EX Series Finishes Applied to a 2-3 mils (50-75 microns) DFT. Theoretical Coverage: 489-326 sq. ft. per gallon (12-8 m 2 per liter). Volume Solids: 61 % Total System Thickness: 2.2-3.5 dry mils (55-87.5 microns) DFT. Specification System #39 39 Vinyl Wash Primer, and Polyurethane Finish Properly Cleaned Galvanized Metal or Aluminum American Coatings WP 9521 Vinyl Wash Primer Applied to a 0.2-0.5 mils (5-12.5 microns) DFT. Theoretical Coverage: 401-160 sq. ft. per gallon (9.9 m 2 per liter). Volume Solids: 5 % American Coatings SU Series Finishes Applied to a 3-5 mils (75-125 microns) DFT. Theoretical Coverage: 331-198 sq. ft. per gallon (8.2-4.9 m 2 per liter). Volume Solids: 62 % Total System Thickness: 3.2-5.2 dry mils (80-130 microns) DFT. Specification System #40 40 Vinyl Wash Primer, and Alkyd Finish Properly cleaned Galvanized Metal or Aluminum American Coatings WP 9521 Vinyl Wash Primer Applied to a 0.2-0.5 mils (5-12.5 microns) DFT. Theoretical Coverage: 401-160 sq. ft. per gallon (9.9-3.9 m 2 per liter). Volume Solids: 5 % American Coatings AK Series Finishes Applied to a various 1.5-2.0 mils (37.5-50 microns) DFT. Theoretical Coverage: Varies 1 Volume Solids: Varies 1 Total System Thickness: 1.7-2.5 dry mils (42.5-62.5 microns) DFT. 1 Varies per product, see data sheet (Tab 2 in catalog) 30

Specification System #41 41 Vinyl Wash Primer, and Acrylic Finish Properly cleaned Galvanized Metal or Aluminum American Coatings WP 9521 Vinyl Wash Primer Applied to a 0.2-0.5 mils (5-12.5 microns) DFT. Theoretical Coverage: 401-160 sq. ft. per gallon (9.9-3.9 m 2 per liter). Volume Solids: 5 % American Coatings AE Series Finishes Applied to a 1.5-2.0 mils (37.5-50 microns) DFT. Theoretical Coverage: 427-320 sq. ft. per gallon (10.5-7.9 m 2 per liter). Volume Solids: 40 % Total System Thickness: 1.7-2.5 dry mils (42.5-62.5 microns) DFT. Specification System #42 42 Silicone Acrylic Primer, and Silicone Acrylic Finish SSPC-SP6 (Sa2) Commercial Blast Cleaning American Coatings SAC Series Primer/Finishes Applied to a 1 mils (25 microns) DFT. Theoretical Coverage: 513 sq. ft. per gallon (12.61 m 2 per liter). Volume Solids: 32 % American Coatings SAC Series Primer/Finishes Applied to a 1 mils (25 microns) DFT. Theoretical Coverage: 513 sq. ft. per gallon (12.61 m 2 per liter). Volume Solids: 32 % Total System Thickness: 2 dry mils (50 microns) DFT. Specification System #43 43 Silicone Acrylic Zinc Primer, and Silicone Acrylic Finish SSPC-SP6 (Sa2) Commercial Blast Cleaning American Coatings SAC 237 Zinc Primer Applied to a 1 mils (25 microns) DFT. Theoretical Coverage: 513 sq. ft. per gallon (12.61 m 2 per liter). Volume Solids: 32 % American Coatings SAC Series Primer/Finishes Applied to a 1.0 mils (25 microns) DFT. Theoretical Coverage: 513 sq. ft. per gallon (12.61 m 2 per liter). Volume Solids: 32 % Total System Thickness: 2 dry mils (50 microns) DFT. 31

Specification System #44 44 Inorganic Zinc Primer, and Silicone Acrylic Finish SSPC-SP6 (Sa2) Commercial Blast Cleaning American Coatings AZ 76 Inorganic Zinc Applied to a 2.5 mils (62.5 microns) DFT. Theoretical Coverage: 436-182 sq. ft. per gallon (10.67-4.5 m 2 per liter). Volume Solids: 68 % American Coatings SAC Series Primer/Finishes Applied to a 1.0 mils (25 microns) DFT. Theoretical Coverage: 513 sq. ft. per gallon (12.61 m 2 per liter). Volume Solids: 32 % Total System Thickness: 3.5 dry mils (87.5 microns) DFT. Specification System #45 45 Silicone Primer, and Silicone Finish SSPC-SP6 (Sa2) Commercial Blast Cleaning American Coatings SL Series Primer Finishes Applied to a 1 mils (25 microns) DFT. Theoretical Coverage: 513 sq. ft. per gallon (12.61 m 2 per liter). Volume Solids: 32 % American Coatings SL Series Primer Finishes Applied to a 1.0 mils (25 microns) DFT. Theoretical Coverage: 513 sq. ft. per gallon (12.61 m 2 per liter). Volume Solids: 32 % Total System Thickness: 2 dry mils (50 microns) DFT. Specification System #46 46 Silicone Zinc Primer, and Silicone Finish SSPC-SP6 (Sa2) Commercial Blast Cleaning American Coatings SL 231 Zinc Primer Applied to a 1.5-2.0 mils (37.5-50 microns) DFT. Theoretical Coverage: 513-385 sq. ft. per gallon (12.6-9.5 m 2 per liter). Volume Solids: 48 % American Coatings SL Series Primer/Finishes Applied to a 1.0 mils (25 microns) DFT. Theoretical Coverage: 513 sq. ft. per gallon (12.6 m 2 per liter). Volume Solids: 32 % Total System Thickness: 2.5-3 dry mils (62.5-75 microns) DFT. 32

Specification System #47 47 Acrylic Latex Block Filler, and Acrylic Latex Finish Water Blast to remove all dirt & dust. American Coatings WB Series Block Filler Applied to a 10-12 mils (250-300 microns) DFT. Theoretical Coverage: 80-67 sq. ft. per gallon (2.0-1.6 m 2 per liter). Volume Solids: 50 % American Coatings WB Finishes Applied to a 1.5-2.0 mils (37.5-50 microns) DFT. Theoretical Coverage: 513-385 sq. ft. per gallon (12.6-9.5 m 2 per liter). Volume Solids: 48 % Total System Thickness: 11.5-14 dry mils (287.5-350 microns) DFT. Specification System #48 48 Water Based Alkyd Primer, and Water Based Alkyd Finish SSPC-SP6 (Sa2) Commercial Blast Cleaning American Coatings HW 3001 Red Oxide Waterbased Latex Primer Applied to a 1.5-2.0 mils (37.5-50 microns) DFT. Theoretical Coverage: 342-257 sq. ft. per gallon (8.4-6.3 m 2 per liter). Volume Solids: 32 % American Coatings HW, AW, or WB Series Waterbase Finish Applied to a 1-1.5 mils (25-37.5 microns) DFT. Theoretical Coverage: 561-374 sq. ft. per gallon (13.8-9.2 m 2 per liter). Volume Solids: 35 % Total System Thickness: 2.5-3.5 dry mils (62.5-87.5 microns) DFT. Specification System #49 49 Latex Roof Coating Primer, and Latex Roof Coating Finish Spot primed surface (AK 3190), water blasting is recommended to remove dust, dirt, or old coatings prior to application. American Coatings WB 11528 Applied to a 10-12 mils (250-300 microns) DFT. Theoretical Coverage: 83-69 sq. ft. per gallon (2.1-1.7 m 2 per liter). Volume Solids: 52 % American Coatings WB 11528 Applied to a 10-12 mils (250-300 microns) DFT. Theoretical Coverage: 83-69 sq. ft. per gallon (2.1-1.7 m 2 per liter). Volume Solids: 52 % Total System Thickness: 20-24 dry mils (500-600 microns) DFT. 33

Specification System #50 50 Latex Shop Coat Primer, and Water Based Latex Finish SSPC-SP3 (St3) Power Tool Cleaning SSPC-SP2 (St2) Hand Tool Cleaning American Coatings HW Series Primer Applied to a 2-3 mils (50-75 microns) DFT. Theoretical Coverage: 300-225 sq. ft. per gallon (5.5-2.7 m 2 per liter) Volume Solids: 28% American Coatings WB Latex Finish Applied to a 2-3 mils (50-75 microns) DFT. Theoretical Coverage: Varies 1 Volume Solids: Varies 1 Total System Thickness: 4-6 mils (100-150 microns) DFT. 1 Varies per product, see data sheet Specification System #51 51 Epoxy Floor System (Thin Film) Allow new concrete surfaces to age approx. 30 days in order to be dry enough to promote good adhesion. Blast to a 1-2 mil anchor profile or chemical clean and etch with American Coatings TH 950 Chemical Cleaner. When using American Coatings TH 950 Chemical Cleaner apply with roller or mop to all surfaces to be coated and allow to be in contact with the concrete for 30-45 minutes. After the cleaner has done it s work, wash thoroughly with fresh water to remove. After concrete is dry, it may be necessary to sweep or buff and remove any dust left after this etching/cleaning step. American Coatings EX Series Epoxy that has been thinned 50% with TH 760 Epoxy Reducer. Applied to a 2-3 mils (50-75 microns) DFT. Theoretical Coverage: 489-326 sq. ft. per gallon (12-8 m 2 per liter). Volume Solids: 61 % Allow 8-10 hours for penetration and curing before application of final coat. This step should seal the pores of the concrete to assure an even glossy finish. Application can be rolled on or sprayed. American Coatings EX Series Epoxy that has been thinned 5-10% with TH 760 Epoxy Reducer or just enough to allow product to flow evenly. Applied to a 2-3 mils (50-75 microns) DFT. Theoretical Coverage: 489-326 sq. ft. per gallon (12-8 m 2 per liter). Volume Solids: 61 % Avoid excess build-up in sharp corners and allow 8-10 hours before putting into service. Third Coat (Optional) American Coatings EX Series Epoxy that has been thinned 5-10% with TH 760 Epoxy Reducer or just enough to allow product to flow evenly. Applied to a 2-3 mils (50-75 microns) DFT. Theoretical Coverage: 489-326 sq. ft. per gallon (12-8 m 2 per liter). Volume Solids: 61 % Avoid excess build-up in sharp corners and allow 8-10 hours before putting into service. Total System Thickness: 4-9 dry mils (150-225 microns) DFT. Note: Aggregate for non-slip surfaces is available from American Coatings. 34

Specification System #52 52 One Component Coal Tar (Oil & Gas Resistant) SSPC-SP3 (St3) Power Tool Cleaning SSPC-SP2 (St2) Hand Tool Cleaning American Coatings CT 1120 Coal Tar Mastic Applied to a 12-15 mils (30-375 microns) DFT. Theoretical Coverage: 50-40 sq. ft. per gallon (1.2-1.0 m 2 per liter). Volume Solids: 38 % Total System Thickness: 12-15 dry mils (300-375 microns) DFT. Specification System #53 53 Coal Tar Epoxy Primer and Coal Tar Epoxy Finish. SSPC-SP6 (Sa2) Commercial Blast Cleaning American Coatings EX 8330 Coal Tar Epoxy Applied to a 6-8 mils (150-200 microns) DFT. Theoretical Coverage: 189-142 sq. ft. per gallon (4.6-3.5 m 2 per liter). Volume Solids: 71 % American Coatings EX 8330 Coal Tar Epoxy Applied to a 6-8 mils (150-200 microns) DFT. Theoretical Coverage: 189-142 sq. ft. per gallon (4.6-3.5 m 2 per liter). Volume Solids: 71 % Total System Thickness: 12-16 dry mils (300-400 microns) DFT. Specification System #54 54 Epoxy Phenolic Primer, and Epoxy Phenolic Finish SSPC-SP5 (Sa3) White Metal Sandblast or NACE No. 1 American Coatings EP 8500 Green Epoxy Phenolic Applied to a 4-6 mils (100-150 microns) DFT. Theoretical Coverage: 260-174 sq. ft. per gallon (6.4-4.3 m 2 per liter). Volume Solids: 65 % American Coatings EP 8520 Gray Epoxy Phenolic Applied to a 4-6 mils (100-150 microns) DFT. Theoretical Coverage: 260-174 sq. ft. per gallon (6.4-4.3 m 2 per liter). Volume Solids: 65 % Total System Thickness: 8-12 dry mils (200-300 microns) DFT. * NOT FOR EXTERIOR USE (Yellowing) 35

Specification System #55 55 Epoxy Flake Filled Phenolic Primer, and Epoxy Flake Filled Phenolic Finish SSPC-SP5 (Sa3) White Blast or NACE No. 1 2 mil anchor profile American Coatings EP 8505 Gray Flake Epoxy Phenolic Applied to a 6-8 mils (150-200 microns) DFT. Theoretical Coverage: 174-130 sq. ft. per gallon (4.3-3.2 m 2 per liter). Volume Solids: 65 % American Coatings EP 8525 Green Flake Epoxy Phenolic Applied to a 6-8 mils (150-200 microns) DFT. Theoretical Coverage: 174-130 sq. ft. per gallon (4.3-3.2 m 2 per liter). Volume Solids: 65 % Total System Thickness: 12-16 dry mils (300-400 microns) DFT. Specification System #56 56 Vinyl Ester Flake Filled Primer, and Vinyl Ester Flake Filled Finish SSPC-SP5 (Sa3) White Metal Blast Cleaning 3-4 mil anchor profile American Coatings TL 41 Flake Vinyl Ester Applied to a 12-15 mils (300-375 microns) DFT. Theoretical Coverage: 134-107 sq. ft. per gallon (3.3-2.6 m 2 per liter). American Coatings TL 41 Flake Vinyl Ester Applied to a 12-15 mils (300-375 microns) DFT. Theoretical Coverage: 134-107 sq. ft. per gallon (3.3-2.6 m 2 per liter). Total System Thickness: 24-30 dry mils (600-750 microns) DFT. *ALLOW 20% FOR SHRINKAGE Specification System #57 57 Epoxy Repair Putty SSPC-SP2 (St3) Power Tool Cleaning SSPC-SP2 (St2) Hand Tool Cleaning American Coatings CL - 10 Adhesive Applied to a 1/4 DFT. Theoretical Coverage: 1 gallon = 231 cubic inches Claw Lok 10 is a two-part gray epoxy putty (1:1 ratio). It cures to a hard, solid plastic surface. It can be trimmed, shaped with tools, or smoothed after curing. Uses Ideal for bonding dissimilar metals, patching tanks, patching and filling pitted valves, pumps, low pressure steam lines, radiators, cast iron pipes, and water tanks. Use with steel patches for repairing the interior or exterior of tanks. Excellent for patching cracks in concrete. Total System Thickness: Unlimited 36 *CAN BE APPLIED UNDERWATER

Specification System #58 58 Pourable Epoxy Grout 1 1/2-3 mil anchor profile on concrete or steel surfaces American Coatings CL - 30 Epoxy Grout Applied up to 4 inches without reinforcement Theoretical Coverage: 0.5 cubic feet per unit A specially developed gray grout offering enhanced bonding properties when used with existing oil free concrete. Has exceptional strength, negligible linear shrinkage, and low water absorption. Good resistance to organic acids, oils, and solvents. Total System Thickness: Unlimited THIS PRODUCT CAN BE USED FOR LEVELING COMPRESSORS, PUMPS, AND ENGINES. ALWAYS POUR USING CAULKED FORMS FOR BEST RESULTS. Specification System #59 59 Reserved Specification System #60 60 Epoxy Novalac Primer, and Epoxy Novalac Finish SSPC-SP5 (Sa3) White Metal Blast Cleaning 2-3 mil anchor profile American Coatings TL 1471 Tan Flake Novalac Applied to a 4-6 mils (100-150 microns) DFT. Theoretical Coverage: 289-192 sq. ft. per gallon (7.1-4.7 m2 per liter) Volume Solids: 72 % American Coatings TL 10329 Gray Epoxy Novalac Applied to a 4-6 mils (100-150 microns) DFT. Theoretical Coverage: 289-192 sq. ft. per gallon (7.1-4.7 m2 per liter) Volume Solids: 72 % Total System Thickness: 8-12 dry mils (200-300 microns) DFT. 37

Specification System #61 61 Flexible Sprayable Epoxy and Caulk 1 1/2 to 3 mil anchor profile on concrete or steel surfaces American Coatings CL8C Applied to a 1/4 to 1-inch thickness. Theoretical Coverage: 6.4-1.6 sq. ft. per gallon CL8C is a Tan Epoxy Putty. It cures to a tough rubber like substance with excellent flexibility and good adhesive properties. Recommended for concrete expansion joints, where resistance to spillage of oils, solvents or chemicals is important. Extremely useful in patching floor cracks, bolted steel joints, areas where vibration is a problem. Spray formula (CL8S) is excellent for sealing the exterior curb of storage tanks between the concrete pad and the steel bottom. Specification System #62 62 Quick Patch Epoxy Adhesive Sand, or power tool to roughen surfaces American Coatings CL 31 Applied to a 1/16 to 1/4-inch DFT. Theoretical Coverage: 12. - 6.4 sq. ft. per gallon (1 gallon = 231 cubic inches). Total System Thickness: 62 dry mils (1550 microns) DFT. * FOR WEAK OR SLOW LEAKS ON TANKS AND VESSELS CL-31 MUST BE BRIDGED OVER BY ANOTHER CLAW LOK PRODUCT FOR BEST RESULTS. Specification System #63 63 Degreaser/Cleaner (non-etching) American Coatings TH 150 Degreaser Mix 4-5 ounces of TH 150 per gallon of water. Theoretical Coverage: 300 sq. ft. per gallon. Volume Solids: N/A Apply by pressure washer, pump sprayer, mop, brush, or broom. Rinse off with clean fresh water. Specification System #64 64 Chemical Cleaner (Etching type) SSPC-SP2 (St3) Power Tool Cleaning SSPC-SP2 (St2) Hand Tool Cleaning American Coatings TH 950 Chemical Cleaner and Acid Etch Theoretical Coverage: 300 sq. ft. per gallon (7.4 m 2 per liter). Volume Solids: N/A Apply by pump sprayer, mop, brush, or broom. Rinse off with clean fresh water, and allow to dry before coating. Allow to sit on concrete surfaces 30 to 45 minutes and remove with water. 38

Specification System #65 65 Rust Converter For best results wire brush to remove dirt and loose rust. American Coatings RL 101 Rust Converter Applied to a 1 mil (25-microns) DFT. Theoretical Coverage: 465 sq. ft. per gallon (11.4 m 2 per liter). Volume Solids: 29 % American Coatings RL 101 Rust Converter Applied to a 1 mil (25-microns) DFT. Theoretical Coverage: 465 sq. ft. per gallon (11.4 m 2 per liter). Volume Solids: 29 % Total System Thickness: 2 dry mils (50 microns) DFT. *Serves as a primer and can receive a solvent based topcoat. *Waterbased products not recommended as a topcoat. NOTE: Apply both coats simultaneously in order to completely wet out old rust. Specification System #66 66 Reserved Specification System #67 67 DTM Polyurethane SSPC-SP6 (Sa2) Commercial Blast Cleaning American Coatings SU DTM Series Polyurethane Applied to a 3-5 mils (75-125 microns) DFT. Theoretical Coverage: 320-192 sq. ft. per gallon (7.8-4.7 m 2 per liter). Volume Solids: 60 % Total System Thickness: 3-5 dry mils (75-125 microns) DFT. * FOR BEST RESULTS BE SURE TO APPLY THE SU DTM COATING 2-3 MILS DRY IN ACCESS OF THE ANCHOR PROFILE ACHIEVED. 39

Specification System #68 68 DTM Alkyd SSPC-SP2 (St2) Hand Tool Cleaning SSPC-SP2 (St3) Power Tool Cleaning American Coatings AK Series Finish Applied to a 1.5-2.0 mils (37.5-50 microns) DFT. Theoretical Coverage: 374-280 sq. ft. per gallon (9.2-6.9 m 2 per liter). Volume Solids: 35 % Total System Thickness: 1.5-2 dry mils (37.5-50 microns) DFT. Specification System #69 69 Automotive Epoxy Primer, and Polyurethane Finish SSPC-SP6 (Sa2) Commercial Blast Cleaning American Coatings AX 8733 Gray or AX 8730 Red Automotive Epoxy Primer Applied to a 1.5-2.0 mils (37.5-50 microns) DFT. Theoretical Coverage: 470-353 sq. ft. per gallon (11.6-8.7 m 2 per liter). Volume Solids: 44 % Mixing Ratio: 4:1 American Coatings SU Series Polyurethane Applied to a 3-5 mils (75-125 microns) DFT. Theoretical Coverage: 331-198 sq. ft. per gallon (8.2-4.9 m 2 per liter). Volume Solids: 62 % Total System Thickness: 4.5-7 dry mils (112.5-175 microns) DFT. Specification System #70 70 Automotive Epoxy Primer, and Acrylic Finish SSPC-SP6 (Sa2) Commercial Blast Cleaning American Coatings AX 8733 Gray Automotive Epoxy Primer Applied to a 1.5-2.0 mils ( 37.5-50 microns) DFT. Theoretical Coverage: 470-353 sq. ft. per gallon (11.6-8.7 m 2 per liter). Volume Solids: 44 % American Coatings AE Acrylic Finish Applied to a 1.5-2.0 mils (37.5-50 microns) DFT. Theoretical Coverage: 428-321 sq. ft. per gallon (10.5-7.9 m 2 per liter). Volume Solids: 40 % Total System Thickness: 3-4 dry mils (75-100 microns) DFT. *For best results catalyze the AE Finish. See your American Coatings representative. 40

Specification System #71 71 Inorganic Zinc SSPC-SP6 (Sa2) Commercial Blast Cleaning American Coatings AZ 76 Inorganic Zinc Primer Applied to a 2.5-6.0 mils (62-150 microns) DFT. Theoretical Coverage: 436-182 sq. ft. per gallon (10.7-4.5 m 2 per liter). Volume Solids: 68 % Total System Thickness: 2.5-6.0 dry mils (62-150 microns) DFT. Specification System #72 72 FC Series Floor System New Concrete surfaces should be allowed to dry for 28 days. Shot Blast or Blast Trac the floor for maximum coatings adhesion. Acceptable also is a chemical cleaning. Use American Coatings TH 950 Chemical Cleaner to remove oil, grease, and etch the concrete surfaces. Allow TH 950 Chemical Cleaner to react 30 to 45 minutes on the concrete surfaces. Remove by fresh water wash, taking care to remove acid completely. Allow to dry and buff or sweep up any loose dust that remains on the concrete surface. American Coatings FC Series Epoxy Applied to a 10-20 mils (250-250 microns) DFT. Theoretical Coverage: 160-80 sq. ft. per gallon (3.9-2.0 m 2 per liter) @ 10-15 mils per coat. American Coatings FC Series Epoxy Applied to desired thickness. Theoretical Coverage: 160-80 sq. ft. per gallon (3.9-2.0 m 2 per liter) @ 10-15 mils per coat. Avoid excess build-up in sharp corners and allow 8-10 hours before putting into service. NOTE:Should you decide to roll the epoxies, make sure that you use a short haired nap industrial roller. FC Series Epoxies have a pot life of approx. 30 minutes. Total System Thickness: Minimum 18-35 dry mils (450-875 microns) DFT. Non slip aggregate is available from American Coatings 41

Specification System #73 73 Latex Surfaces to be clean and dust free. American Coatings WB Acrylic Latex Finish Applied to a 2-3 mils (50-75 microns) DFT. Theoretical Coverage: Varies 1 Volume Solids: Varies 1 Total System Thickness: 2-3 dry mils. 1 Varies per product, see data sheet Specification System #74 74 100 % Solids Tank Lining (One Coat) SSPC-SP5 (Sa3) White Metal Blast Cleaning American Coatings TL 13506 Gray 100% Solids Tank Lining Applied to a 15-20 mils (375-500 microns) DFT. Theoretical Coverage: 107-80 sq. ft. per gallon (2.6-2.0 m 2 per liter). Total System Thickness: 15-20 dry mils (375-500 microns) DFT. Holiday test recommended. This product should be applied pin hole free. Striping should first be done then a pin hole free coating should be applied. Specification System #75 75 CL-19 100% Solids Cargo Liner SSPC-SP6 (Sa2) Commercial Blast Cleaning American Coatings CL-19 100% Solids Cargo Liner Applied to a 1/8-1/2 inch DFT (1 gal = 231 cubic inches). Total System Thickness: 1/8-1/2 inch Product sprayed with special plural component machinery heated to approx. 120-135 F Specification System #76 76 Flexible Caulk SSPC-SP6 (Sa2) Commercial Blast Cleaning CLSC Flexible Epoxy Caulk Applied to a 1/8-1/2 inch DFT (1 gal = 231 cubic inches). Total System Thickness: 1/8-1/2 inch Product sprayed with special plural component equipment 42

Specification System #77 77 Epoxy Automotive Primer, and Polyurethane Automotive Top Coat Sand all surfaces to be coated to improve adhesion then solvent wipe with American Coatings TH 315 thinner to remove any gel coat release wax that may be present. American Coatings AX 8733 Gray Automotive Epoxy Primer Applied to a 1.5-2 mils (37.5-50 microns) DFT. Theoretical Coverage: 408-321 sq. ft. per gallon (11.6-8.7 m 2 per liter). Volume Solids: 44 % American Coatings AU Series Acrylic Polyurethane Applied to a 1.5-2 mils (523-314 microns) DFT. Theoretical Coverage: 200-134 sq. ft. per gallon (4.9-3.3 m 2 per liter). Volume Solids: 50 % Total System Thickness: 3-4 mils (75-100 microns) DFT. Specification System #78 78 Alkyd Spot Primer, Alkyd Oil Mid Coat, and Alkyd Oil Finish Pressure wash all areas to be coated Primer American Coatings AK 3190 Applied to a 2 mils (50 microns) DFT. Theoretical Coverage: 344 sq. ft. per gallon (8.5 m 2 per liter). Volume Solids: 43 % American Coatings AK 3280 Galvanized Iron Primer Applied to a 1.5-2 mils (37.5-50 microns) DFT. Theoretical Coverage: 460-345 sq. ft. per gallon (11.3-8.5 m 2 per liter). Volume Solids: 43 % American Coatings AK 3280 Galvanized Iron Primer Applied to a 1.5-2 mils (37.5-50 microns) DFT. Theoretical Coverage: 460-345 sq. ft. per gallon (11.3-8.5 m 2 per liter). Volume Solids: 43 % Total System Thickness: 5-6 mils (125-150 microns) DFT. Specification System #79 79 White Strippable Coating Clean and degrease all surfaces to be coated. American Coatings WB 7777 White Strippable Coating Applied to 5 mils (125 microns) DFT. Theoretical Coverage: 154 sq. ft. per gallon (3.8 m 2 per liter). Volume Solids: 48 % Total System Thickness: 5 mils (125 microns) DFT. 43

Specification System #80 80 NSF 61 (Potable Water) SSPC-SP5 (Sa3) White Metal Sandblast or NACE No. 1 American Coatings EM 4650 Tan High Build Epoxy Applied to a 4-6 mils (100-150 microns) DFT. Theoretical Coverage: 260-173 sq. ft. per gallon (6.4-4.3 m 2 per liter). Volume Solids: 65 % American Coatings EM 4651 White High Build Epoxy Applied to a 4-6 mils (100-150 microns) DFT. Theoretical Coverage: 260-173 sq. ft. per gallon (6.4-4.3 m 2 per liter). Volume Solids: 65 % Total System Thickness: 8-12 mils (200-300 microns) DFT. Specification System #81 81 Degreaser, Epoxy Primer, and Polyurethane Finish Clean thoroughly with American Coatings TH 150 or TH 200 Cleaner / Degreaser. Wash with water (not necessary with TH 200). American Coatings EM, EX, RL, or AX Series Epoxy Primer to recommended thickness. Applied to correct milage on Spec Sheet (Varies 1 ) Theoretical Coverage: Varies 1 Volume Solids: Varies 1 American Coatings PU, SU, AU, or VU Series. Applied to correct milage on Spec Sheet (Varies 1 ) Theoretical Coverage: Varies 1 Volume Solids: Varies 1 Total Thickness: 6-9 mils (150-225 microns) DFT. 1 Varies per product, see data sheet (Tab 6 in catalog) Specification System #82 82 Reserved 44

Specification System #83 83 Jet Fuel System (4556D) SSPC-SP5 (Sa3) White Metal Sandblast or NACE No. 1 American Coatings EM 4654 Applied to a 4-6 mils (100-150 microns) DFT. Theoretical Coverage: 706-529 sq. ft. per gallon (17.6-11.8 m 2 per liter). Volume Solids: 44 % American Coatings EM 4654 Applied to a 4-6 mils (100-150 microns) DFT. Theoretical Coverage: 706-529 sq. ft. per gallon (17.6-11.8 m 2 per liter). Volume Solids: 44 % Total System Thickness: 8-12 mils (200-300 microns) DFT. Specification System #84 84 100% Solids Epoxy Lining (non laminating) SSPC-SP5 (Sa3) White Metal Sandblast or NACE No. 1 Stripe Coat American Coatings TL 12721 Applied to all welds and hard to coat areas first. Theoretical Coverage: 1604 sq. ft. per gallon (39.7 m 2 per liter). Primer Coat American Coatings TL 12721 Applied to a 10-20 mils (250-500 microns) DFT. Theoretical Coverage: 160-80 sq. ft. per gallon (3.9-2.0 m 2 per liter). Finish Coat American Coatings TL 12721 Applied to a 10-20 mils (250-500 microns) DFT. Theoretical Coverage: 160-80 sq. ft. per gallon (3.9-2.0 m 2 per liter). Total System Thickness: 20-40 mils (500-1000 microns) DFT. Specification System #85 85 Epoxy with Glass Wrap SSPC-SP3 (St2) Manual Cleaning American Coatings TL 1 Applied to a 10-12 mils (250-300 microns) DFT. Theoretical Coverage: 160-134 sq. ft. per gallon (3.9-3.3 m 2 per liter). American Coatings TL 1 with glass tape Applied to a 55 mils (1375 microns) DFT. Theoretical Coverage: 160-134 sq. ft. per gallon (3.9-3.3 m 2 per liter). Third Coat American Coatings TL 1 Applied to a 10-12 mils (250-300 microns) DFT. Theoretical Coverage: 160-134 sq. ft. per gallon (3.9-3.3 m 2 per liter). Total System Thickness: Approx. 60-75 mils (1500-1875 microns) DFT. 45

Specification System #86 86 Epoxy Primer SSPC-SP2 (St2) Hand Tool Cleaning American Coatings EX 8300 Epoxy Primer Applied to a 2-3 mils (50-75 microns) DFT. Theoretical Coverage: 489-326 sq. ft. per gallon (12-8 m 2 per liter). Volume Solids: 61 % Total System Thickness: 4-6 mils (50-75 microns) DFT Specification System #87 87 Reserved Specification System #88 88 Chemical Cleaner, Epoxy Primer, and Polyurethane Finish SSPC-SP2 (St2) Hand Tool Cleaning Preparation Apply American Coatings TH 950 Chemical Cleaner to all surfaces to be painted, allow to set 1 hour, then wash off with fresh water. Will not work on painted surfaces. American Coatings EX 8300 Epoxy Primer Applied to a 2-3 mils (50-75 microns) DFT. Theoretical Coverage: 489-326 sq. ft. per gallon (12-8 m 2 per liter). Volume Solids: 61 % American Coatings PU, SU, AU, or VU Series Applied to a 2-3 mils (50-75 microns) DFT. Theoretical Coverage: Varies 1 Volume Solids: Varies 1 Total Thickness: 4-6 mils (100-150 microns) DFT. 1 Varies per product, see data sheet (Tab 6 in catalog). 46

Specification System #89 89 Flake Glass Polyester SSPC-SP10 (Sa2 1/2) Near-White Blast Cleaning American Coatings TL 15 Flake Glass Filled Polyester (Isopthalic) Applied to a 12-15 mils (300-375 microns) DFT. Theoretical Coverage: 134-107 sq. ft. per gallon (3.3-2.6 m 2 per liter). * American Coatings TL 15 Flake Glass Filled Polyester (Isopthalic) Applied to a 12-15 mils (300-375 microns) DFT. Theoretical Coverage: 134-107 sq. ft. per gallon (3.3-2.6 m 2 per liter). * Total System Thickness: 24-30 mils (600-750 microns) DFT. * Has 20% Shrinkage Specification System #90 90 Alkyd Finish Surface free of dirt, dust, and grease American Coatings AK 6000, AK 4000, AK 7000 Series Applied to a 1.5-2.0 mils (37.5-50 microns) DFT. Theoretical Coverage: Varies 1 Volume Solids: Varies 1 (Optional) American Coatings AK 6000, AK 4000, AK 7000 Series Applied to a 1.5-2.0 mils (37.5-50 microns) DFT. Theoretical Coverage: Varies 1 Volume Solids: Varies 1 Total System Thickness: 1.5-4.0 mils (37.5-100 microns) DFT. 1 Varies per product, see data sheet (Tab 5 in catalog). 47

10 Robert Wilson Rd Longview, TX 75602 Toll Free: (800) 749-7080 Phone: (903) 758-0051 Fax: (281) 351-6348 AMERICAN COATINGS www.americancoatings.com