Installation IMPORTANT! Aerada 900 Series Futura Faucet With Accu-Zone (AZ) Infrared Control

Similar documents
DISCONTINUED. Installation. Aerada 900 Series Futura Faucet. With Accu-Zone (AZ) Infrared Control

Installation Instructions

Installation Instructions

Installation For Service Only

Installation S AST4 S TT S IR. Stainless Steel Wall-Hung BradMate Washfountain

Installation HSL1/IR HSL1/BIR3. Ligature Resistant Single-Station Lavatory. Table of Contents

Installation. Aerada 1200 Series CS Faucet S Battery-Operated Capacitive Sensing Gooseneck Faucet IMPORTANT

Supplies Required. Teflon Tape Allen Key Wrenches Screwdriver 1/2" NPT Brass Pipe Plug Adjustable Wrench IMPORTANT!

Installation. S AST4 S TouchTime S Infrared. Stainless Steel Wall-Hung BradMate Washfountain

Parts & Service. Sentry Washfountain Discontinued Models Prior to February 1, SN " Semi-Circular, Floor-Mounted

Installation. SS-1N (bowl only) SS-1N/IR SS-1N/BIR3 SS-1N/TT. Express Lavatory System SS-Series. Table of Contents

Installation Instructions

Installation. MG-2 Infrared. Express Lavatory System - MG Series with Adaptive Infrared. Table of Contents

Parts & Service. Terreon Multi-Fount Washfountain Current Models After February 1, MF2922 Corner-Fount. MF2933 Tri-Fount

Installation. SS-1N (bowl only) SS-1N Infrared SS-1N Battery Infrared SS-1N Touch Time. Table of Contents. Express Lavatory System SS-Series

Installation MF2933/TT

Sentry Washfountain Parts & Service Guide

Installation S19-220PT S19-220BPT. Wall-Mounted Eyewash with Plastic Bowl. Wall-Mounted Eyewash with Stainless Steel Bowl

INSTALLATION INSTRUCTIONS

Installation. ABP-1C TouchTime Ablution System IMPORTANT! Table of Contents Rev. B; ECN E 2014 Bradley Page 1 of 5 10/6/2014

INSTALLATION INSTRUCTIONS

Installation MF2939/AST4

Optima ETF-600/ETF-610

INSTALLATION MANUAL Aplos Single Handle Vessel Bathroom Faucet KEF I toll free: I Kraus USA Inc. I REV

Installation Instructions

INSTALLATION INSTRUCTIONS

Optima ETF-500. Hand Hygiene. Repair Parts and Maintenance Guide PARTS LIST ETF-500 FAUCET ETF-500. See page 157 for faucet cable extension cords.

Installation S19-220P. Wall-Mounted Eye/Face Wash. Table of Contents P Rev. P; ECN C 2012 Bradley Page 1 of 5 10/18/2012

Installation Instructions

S-9100, S-9200, S-9300, S-9400, S-9700, S-9800

Installation S19-130BF Plastic Showerhead S19-130ABF Plastic Showerhead with Stainless Steel Shroud Drench Shower Vertical Supply Table of Contents

Installation MF2922/BIR3

ETF-600 Sensor Operated Lavatory Faucet

INSTALLATION INSTRUCTIONS

Installation Instructions

WARNING NOTICE IMPORTANT

Installation S19-310NN. Frost-Proof Combination Drench Shower and Eyewash (18", 3', 4', 5' or 6' Bury Depth)

INSTALLATION INSTRUCTIONS

EBF-750 Deck-Mounted Battery Powered Sensor Operated Gooseneck Faucets

Installation. Tools. Single Handle Kitchen Faucet With Optional Spray. Maintenance. Safety Tips. Important Points. Need Help? For Model:

Sensor Activated Lavatory Faucet Installation, Operation & Service Instructions Model Numbers Tools & Materials Need Help?

G SERIES - E TOUCH MIXER / TAP

BASYS INSTALLATION INSTRUCTIONS FOR ELECTRONIC CAPACITANCE SENSING LAVATORY FAUCETS EFX-3XX Pedestal, Sensor Activated Lavatory Faucets

WARNING NOTICE IMPORTANT

Installation S19-310F. Combination Drench Shower and Eyewash

Installation S19-220BF. Wall-Mounted Eyewash

INSTALLATION INSTRUCTIONS

Geo Arch Single Lever Pull-Down Kitchen Faucet With Soap Dispenser

Milano AUTOMATIC FAUCET

T&S BRASS AND BRONZE WORKS, INC.

DISCONTINUED. Installation S19-310FSS. Stainless Steel Combination Drench Shower and Eyewash

HYDROTEK INTERNATIONAL, INC Forsyth Commerce Rd., Ste. 124, Orlando, FL Phone (800) / Fax (866)

INSTALLATION MANUAL IMPORTANT CONSIDERATIONS TECHNICAL INFORMATION. Tools you may need

Seda Single Lever Basin Faucet

Installation. S19284H (Eyewash) S19284J (Eye/Face Wash) Cabinet-Mounted Swing-Down Eyewash and Eye/Face Wash. Table of Contents

Installation. S19284HB (Eyewash) S19284JB (Eye/Face Wash) Barrier-Free Cabinet-Mounted Swing-Down Eyewash and Eye/Face Wash.

Installation Instructions

Installation. S19284HB (Eyewash) S19284JB (Eye/Face Wash) Barrier-Free Cabinet-Mounted Swing-Down Eyewash and Eye/Face Wash.

Installation S19-130BF S19-130ABF. Drench Shower - Vertical Supply. Table of Contents

INSTALLATION MANUAL IMPORTANT CONSIDERATIONS TECHNICAL INFORMATION. Tools you may need

INSTALLATION INSTRUCTIONS

LIGATURE RESISTANT SENSOR FAUCET

Installation. E19-310AC Combination Drench Shower and Eye/Face Wash. Table of Contents

Installation S19-130BF S19-130ABF. Plastic Showerhead. Plastic Showerhead with Stainless Steel Shroud Drench Shower Vertical Supply

Installation Instructions

DISCONTINUED. Installation S19-310SS16. Stainless Steel Combination Drench Shower and Eyewash. Table of Contents

Ventus Single Handle Vessel Bathroom Faucet

Single Lever Pull-Down Kitchen Faucet

SAVE FOR CONSUMER INSTALLATION / OWNER'S MANUAL. Single Handle Kitchen Faucet Model # LK2500. Important! You choose the flow rate!

Installation. Bradley S19 210ss Pedestal Mounted Eye Face Wash Bradley S Eye Face Wash Hand or Foot S19-210SS. netzerotools.

Installation Instructions Series Series

Aplos Single Lever Vessel Faucet

Installation Instructions

INSTALLATION INSTRUCTIONS

Single Lever Pull-Out Kitchen Faucet

Installation S19-310LL. Combination Drench Shower and Eyewash

Aquila Single Lever Vessel Faucet

Installation S19-220ABF S19-220BBF. Wall-Mounted Barrier Free Eyewash with Plastic Bowl. Wall-Mounted Barrier Free Eyewash with Stainless Steel Bowl

Installation Instructions

Geo Arch Single Lever Pull-Down Kitchen Faucet With Soap Dispenser

Installation S19-120BF S19-120ABF. Plastic Showerhead. Plastic Showerhead with Stainless Steel Shroud Drench Shower - Horizontal Supply

Electronic Faucet - 591T Series

HYDROTEK INTERNATIONAL, INC Forsyth Commerce Rd., Ste. 124, Orlando, FL Phone (800) / Fax (866)

Installation Instructions JASMINE Spread Lavatory Faucet with the EverClean Finish & Speed Connect Drain

OBSOLETE. Installation S19-325BF S19-325FBF S19-325PBF S19-325FPBF

AEF-300/300T SERIES SENSOR FAUCET SYSTEMS

HYDROTEK INTERNATIONAL, INC Forsyth Commerce Rd., Ste. 124, Orlando, FL Phone (800) / Fax (866)

Installation Instructions

INSTALLATION INSTRUCTIONS

Installation Instructions

Installation S19-315BF S19-315FBF S19-315PBF S19-315FPBF

SERIN MONOBLOCK LAVATORY FAUCET with

Installation Instructions

Installation Instructions

Installation S19-220Y. Wall-Mounted Eyewash. Table of Contents

Operation and Service Guide: Showers

Installation Guide. Single-Control Bath and Shower Trim A K K K 12021

Installation Instructions

EZ FILL FAUCET AUTOMATIC DECK MOUNTED FAUCET INSTALLATION AND MAINTENANCE GUIDE

Installation. S19284H (Eyewash) S19284J (Eye/Face Wash) Cabinet-Mounted Swing-Down Eyewash and Eye/Face Wash. Table of Contents

Transcription:

Aerada 00 Series Futura With Accu-Zone (AZ) Infrared Control S3-3 S3-3TL..." Centerset S3-3TMA... " Centerset w/ TMV S3-3..." Centerset, no Solenoid Valve S3-33TL...Centershank S3-33TMA... Centershank w/tmv S3-3...Centershank, no Solenoid Valve S3-3TL..." Centershank w/" Trim Plate S3-3TMA... " Centershank w/ " Trim Plate, TMV S3-36..." Centershank w/ " Trim Plate, no Solenoid Valve Supplies Required... Dimensions and Configurations...... 3 Multi- Wiring... Replacing the Sensor... Troubleshooting... THIS SIDE UP Packing List IMPORTANT! Read this entire installation manual to ensure proper installation. When finished with the installation, file this manual with the owner or maintenance department. Compliance and conformity to local codes and ordinances is the responsibility of the installer. Separate parts from packaging and make sure all parts are accounted for before discarding packaging material. If any parts are missing, do not begin installation until you obtain the missing parts. Make sure that all water supply lines have been flushed and then completely turned off before beginning installation. Debris in supply lines can cause valves to malfunction. A transformer (supplied by Bradley or supplier) should be used in conjunction with the 00 Series Futura (AZ) s. The transformer MUST be VAC. Connection to 0 VAC could result in personal injury and will damage the sensor. When the faucet is mounted on a fixture with a stainless steel bowl, it is recommended that the bowl have a satin finish rather than a mirrored or highly polished finish. Product warranties may be found under Products on our web site at bradleycorp.com. -60 Rev. C ECN 3-0-00 03 Bradley Page of 6 3//03 P.O. Box 30, Menomonee Falls, WI USA 30-030 PHONE 00.BRADLEY (00..33) FAX 6.. bradleycorp.com

Aerada 00 Series Futura Supplies Required 0 VAC power source and 0 VAC/ VAC transformer (Bradley part no. S3-00: must be ordered separately) OPTIONAL: Remote wiring from faucet to transformer; electrical box for transformer if required by local code -gauge two-conductor lamp cord (if additional wire length is required) Tempered/cold supply piping and fittings to solenoid valve (/" NPT) /" O.D. tubing Pipe fittings, pipe sealant as required Dimensional Information " () -/6" () -/" () Centershank Mounting " (03) Centerset Mounting " (0) (mm) -/" () Drilled Hole Nut & Washer 3/" (0) Drilled Hole Stud Copper Tubing Washer Nut Copper Tubing 3/" () Drilled Hole Mounting Configurations 3 Parts List Ref. Part No. Description 0- Mounting Nut 6 0 6-00CB Mounting Washer 3 6- " Trimplate Mounting Screw S- Mounting Prepack -3 " Trimplate 6 6-0 Sensor Bracket Nut -00BS Sensor Bracket Washer - Sensor Bracket S3-00 Sensor Assembly 0 60-6 Sensor Mounting Screw Centerset Mounting Centershank Mounting Components Fitting Assy. (S0-3) Sensor Sensor Window (6-60) Flow Control Aerator Assy. (S0-A) Adapter (3-6) Centershank 3//03 Bradley -60 Rev. C; ECN 3-0-00

Aerada 00 Series Futura Mount on Deck Centerset A Drill holes in deck to the size and position for your faucet configuration, as shown on previous page. B Attach faucet and trim plate (if applicable) securely to deck. Seal around faucet and trim plate with plumber's putty. Deck Connect Water Supply Centershank Washer Nut *Solenoid valve not included on some models. Hot Inlet /" NPT Solenoid Valve* /" O.D. Tubing (Supplied by Installer) (30" max. length, IPC, section 60.; UPC, section 60.) TMA Navigator 3 Connect the Electric Supply Cold Inlet /" NPT Centershank From Transformer Brown 0VAC/VAC Transformer Avalable as a separate item (Bradley Part No. S3-00) Blue Black Adapter 6-60 Solenoid Valve* *Solenoid valve not included on some models. Bradley -60 Rev. C; ECN 3-0-00 3//03 3

H Aerada 00 Series Futura For Units Equipped with TMA Navigator Mixing Valve, Complete steps and Below: Adjust Temperature with Water Running This valve is NOT factory preset. Upon installation, the temperature of this valve must be checked and adjusted to ensure delivery of a safe water temperature. Water in excess of 0 F (3 C) may cause scalding. A Loosen Cap Screw about /" (-6 turns) and lift up cover (do not remove). B Using cover, turn cartridge gently until desired water temperature is reached. Do not turn past stops as this may damage unit. Push cover down and tighten screw. C Test Unit DO NOT SKIP THIS STEP!!! Shut the hot water inlet off by closing hot water inlet valve. While the hot water supply is turned off, check to make sure the cold water flow is reduced. If the cold water is reduced properly, reopen the hot water supply. Shut the cold water inlet off by closing the cold water inlet valve. While the cold water supply is off, check to make sure that the hot water flow has shut down. Multi- Wiring One transformer operates up to four faucets at one time. Additional transformer(s) are required for installations with more than four faucets. Refer to the transformer's installation manual for remote mounting instructions. Brown Black Blue 3//03 Bradley -60 Rev. C; ECN 3-0-00

Aerada 00 Series Futura Replacing the Sensor To avoid personal injury and/or damage to the faucet, TURN OFF the electrical power and water BEFORE beginning any cleaning, troubleshooting or maintenance. A Disconnect the sensor wire leads from the faucet and remove the faucet from the deck. B Following the illustrations at right for your faucet configuration, remove the screws and/or nuts holding the bracket, then carefully remove the bracket and sensor assembly from the faucet shell. Bracket IR Sensor C Remove screws securing the existing sensor to bracket. of the new sensor is the reverse process. Centershank Mounting Centerset Mounting Troubleshooting Solenoid Valve Sensor must be flush and parallel with the lens. Do not force or bend the bracket! S0-06 Problem Cause Solution fails to shut off and drips. There is debris trapped between the diaphragm and the valve seat Remove debris between diaphragm and the valve seat:. Remove the three # Phillips-head screws that hold the solenoid valve assembly together. Be careful not to lose the armature or spring (see Parts List). 6 fails to turn on. A failed coil for the valve or loose electrical connection to the terminal.. Remove the diaphragm. Remove any particles that have been trapped between the diaphragm and the valve seat. Rinse off the diaphragm and inspect for damage. Make sure the center orifice and both small side orifices are open. 3. Reassemble in reverse order, being careful not to overtighten the Phillips-head screws or you may crack the plastic valve body. Tighten until the armature plate makes contact with the plastic body.. Reconnect the wiring per diagram on page 3. Repair loose connection. (If faucet still does not operate, replace coil.) 3 Parts List for S0-06 Ref. Part No. Description -30 Valve Body, /" Closed 0 6-3 Diaphragm 3 6- Armature 6- Spring 6- Armature Housing 6 6-30 Clamp, Armature Housing 6- Coil, Solenoid Valve 60- Screw, # x /" -6 O-Ring, #-03 0* -60 Flow Restrictor,. GPM * Not included with S0-06. Bradley -60 Rev. C; ECN 3-0-00 3//03

Aerada 00 Series Futura Troubleshooting Thermostatic Mixing Valve Before attempting to troubleshoot the valve or disassemble the components, check for the following conditions: If stop valves are used, make sure that they are fully open. Make sure that the hot and cold inlet pipes are connected properly, and that there are no cross-connections or leaking stop valves. Check the hot water heater output to make sure that it is at least 0 F above the set temperature. Close the appropriate shut-off valves prior to disassembly and reopen valves after inspection and repair is complete. Problem Cause Solution External leaks. Improper water temperature or temperature fluctuation. Limited water flow. Damaged cartridge or O-rings. Hot water supply is not 0 above desired set point. Valve temperature is not properly set. Dirt and debris have built up in the valve or strainer. Replace cartridge with part number 6- Increase hot water supply temperature Adjust the temperature as shown on page step.. Check to make sure both hot and cold supplies are connected to the Navigator mixing valve and that they have water flow.. Remove cover and U-clip. Remove the cartridge and clean the strainer. It is not required to grease cartridge, however if desired, use silicone grease only. Do not use grease on check valves. S0-6 3 Parts List for S0-6 Ref. Part No. Description 60-63 Cap Screw 0- Cover 3 6- Thermostatic Cartridge -0 Check Valve* 3-0 Retaining Ring* 6 6-0 U-Clip -3 Valve Body * Included with Prepack S6-36 Tempered Line Adapter Option: Part no. S3-0 6 Strainer 3-0 6 3//03 Bradley -60 Rev. C; ECN 3-0-00