Innovation in soft start technology HFE-2 USER MANUAL. MAN-HFE-002. Version 01

Similar documents
Guide to contents - applicable to

1.1 Caution Statements

ACCESS Always replace the cover panel on the unit after gaining access to the electrical connections.

Synergy EN product information

2.1 Warnings & Agency Approvals Electrical Connections - Specifications Standard Wiring Configurations...2 4

Soft Starters and Energy Optimising Soft Starters Guide to contents - applicable to


1 Phase electronic contactor (SC 1)

RVS-AX Instruction Manual

MINIATURE CIRCUIT BREAKER

Miniature Circuit Breaker

AF40... AF96 3-pole contactors Technical data

Index. Manual Motor Starters 1. Auxiliary Contact Blocks 1. Trip Alarm Auxiliary 1. Switch. Shunt Release 1. Under-voltage Release 2.

CI-Tronic Soft start motor controller MCI 3, MCI 15, MCI 25, MCI 30 I-O, MCI 40-3D and MCI 50-3 I-O

MAKING MODERN LIVING POSSIBLE. Quick Setup VLT FCM 300 Series. Phone: Fax: Web: -

Soft Starter. Types RSBD. Product Description. Type Selection. Ordering Code RSB D E V 61 HP

Technical Manual Electrical Power Supply System T4002

CI-tronic Soft Start Motor Controller Type MCI 25B with Brake

DX³ RCCBs - ID 4P up to 100 A

Motor Controllers AC Semiconductor Motor Controller Type RSHP Flexy

DEVICE STATE/BYPASSED FAILURE OVERLOAD

MAKING MODERN LIVING POSSIBLE. Design Guide VLT MCD 100 Soft Starter the single speed drive

70 RT HP SWITCH DISCONNECTORS IN PLASTIC BOX

FLÄKTGROUP PM-MOTOR WITH INTEGRATED FC 106 FREQUENCY CONVERTER

Starting Torque Limiter Type TCI (Soft Start)

SDS Enclosed Star-Delta Starter User Guide

TX³ RCCBs 2P up to 100 A

Data sheet. CI-tronic Soft start motor controller Type MCI 3, MCI 15, MCI 25, MCI 30 I-O, MCI 50 I-O 520B1443

Control and Load Switch Specifications Bulletin Number 194E, 194L

RE-PR3-E-86&105 3-Phase Panel Mount 86 and 105kW

D509E. Manual Motor - Starters

Electronic overload relay EF65, EF96 and EF146

HIB Enclosed Inverter User Guide

Electronic overload relays EF205 and EF370

Commander SK. Technical Data Guide. Model sizes A to D and 2 to 6. AC variable speed drive for 3 phase induction motors


Short-circuit current limiter S800-SCL-SR

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases

This manual is to be given to the end user. Optional RFI filter. Drive. Stop. Thermal protection device. Start / Reset +DC.

RE-PR1-F 1-Phase Din-Rail Mount 1.5, 3 & 6kW

Limit Switch - Safety Type with pull button reset Plastic Body IP65 and Metal Body IP66

User Guide. Digistart CS. 7.5kW - 110kW (18A - 200A) 200V, 400V, 575V

MANUAL CONTROL UNIT FOR ROTATING HEAT EXCHANGER. MicroMax. Article no. F IBC control Made in Sweden

Short Form Guide. Unidrive SP. Part Number: Issue: 2.

Application Description

Open Chassis Star-Delta Starter User Guide

Selection Guide Motor Control Device Solutions

SOLSTART Instruction Manual

DX³ RCBO 4500/6 ka Phase + Neutral, neutral on left

Cat. N (s) : /65/66/83/84, /94/95/96/99, /01/02/06/07/11/12/13/14. Pollution degree : C / + 40 C. .

Circuit breakers and switch-disconnectors NT06 to NT16 and NW08 to NW63

Motor Controllers AC Semiconductor Motor Controller Type RSHP Flexy

Manual Motor Starters. Meta-MEC

Instruction Manual PC104/PC105 3-PHASE SOCKET TESTER. Check out what else you can get from Martindale:

Safety rope switches with reset for emergency stop

Specification for 70mm pole pitch Air circuit breaker up to 1600 A

IBC control. MicroMax MANUAL. With adjustable boost function and threshold value. Since Set of EMC-glands as an option

Phase + Neutral, neutral on left side

AF09... AF30 3-pole Contactors up to 25 HP / 600 VAC

AF40... AF96 3-pole contactors 30 to 60 hp at 480 V AC AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts

013 : 2009 CEB SPECIFICATION MOULDED CASE CIRCUIT BREAKERS

Solenoid interlocks AZM 190 range. 128 Schmersal ,3 4,5 M20 17,5 23,5

ASTAT XB USER MANUAL. 1 Caution Statements

3NP1 Fuse Switch Disconnectors up to 630 A

Contactor Relays 3TH30

Btdin-RS RCBO 2p Phase + Neutral, neutral on right

schneider-electric.com/sg K60 Circuit Breakers The affordable way to stay safe from electrocution and electrical overloads schneider-electric.

DPX Thermal magnetic and trip-free switches DPX 3 -I 630

GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector

Phase + Neutral, neutral on right side

Model 340i / 680i / 1220i DC drive product manual HG iss 8 1

Protection components

SD Series Non-Fused Load Switches

Latch for Contactors 4-pole see page 36. Ratings Rated Aux. Contacts Type Coil voltage 2) AC2 Current Built-in Additional 24 24V= DC 5

Installation Manual. 13.5Vdc 5A Series N645 MODELS : TPS13-5Si TPS13-5SiB TPS13-5SiBD TPS13-5SiBD-20

Operating Instructions. VLT Soft Starter - MCD 500. Phone: Fax: Web: -

DX³ 4-pole RCBO 6000 A/10 ka

020: 2013 CEB SPECIFICATION MINIATURE CIRCUIT BREAKER (MCB)

LEXIC Curv LIMOGES Cedex. Cats N (s) : /68/87/88, /48, /84/85, /76/77/95/96/97, /71/72 1.

Thyristor power controller TE10A. Burst-firing Single-cycle Advanced Single-cycle

Operating Instructions. Drives Solutions.

Reduced Voltage Motor Starters

CI-TI Contactors and motor starters Types CI 61 - CI 98

ATX DPD Series Distribution Panelboards Flameproof

MODVAR Low voltage reactive power compensation modules Installation manual

RX 3 MCB 4500 A Phase + Neutral, neutral on left side

3 - Protection components Motor circuit-breakers

DNX 3 MCB 4500 A / 6 ka Phase + Neutral, neutral on left side

Power Electronics. MINISTOP Motor Brake Relay BA 9034N

MOTORTRONICS Solid State AC Motor Control

Instruction Manual. Harmonic Filter AHF 005/010. Drives Solutions

RESIDUAL CURRENT CIRCUIT BREAKER

Appendix: Safety and application notes for... 15

cor Long Run Experience

LV Capacitor CLMD03 Power Module Instruction manual

amp ramp Operators Manual Page 1 Saftronics 2S Ltd Turnbridge Mills Quay Street Huddersfield West Yorkshire HD1 6QT

, , PREPARATION - CONNECTION. Mounting:. On symmetrical EN rail or DIN 35 rail

SynergEX Panelboards. Installation & Maintenance Information IF Panelboards for Hazardous Locations SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE

RS-3 PRO RS-1007 PRO. CAT IV Analog Clamp meter Series. Users Manual. For detailed specifications and ordering info go to

Dimensions WxHxD [mm] Weight [kg]

Transcription:

Innovation in soft start technology HFE-2 USER MANUAL MAN-HFE-002. Version 01

HFE-2 user guide Fairford Electronics Ltd Bristow House Gillard Way, Ivybridge PL21 9GG UK www.fairford.com 2016 by Fairford Electronics, all rights reserved Copyright subsists in all Fairford Electronics deliverables including magnetic, optical and/or any other soft copy of these deliverables. This document may not be reproduced, in full or in part, without written permission. Enquiries about copyright of Fairford Electronics deliverables should be made to Fairford Electronics Ltd. If, by permission of the copyright owner, any part of this document is quoted, then a statement specifying the original document shall be added to the quotation. Any such quotation shall be according to the original (text, figure or table) and may not be shortened or modified. The manufacturer does not assume any liability, express or implied, for any consequences resulting from inappropriate, negligent or incorrect installation, application, use or adjustment of the product or circuit design, or from mismatching of a soft starter to a motor 1

Optimising Motor Control (iers) HFE Energy Saving soft starters are designed to control single phase AC motors. Operation is fully automatic, a low starting voltage is applied to the motor as soon as the supply is switched on. The internal automatic ramp control is immediately activated and raises the voltage progressively, causing the motor to accelerate smoothly. At the end of the ramp period, the motor is operated in Energy Saving (iers) mode and the HFE continuously regulates the voltage to match mechanical load. Energy consumption at light loads is reduced, motor winding and case temperatures are lowered, motor life is extended, noise levels are reduced and power factor is improved. Two LED s on the front of the unit indicate when the POWER supply is connected and when the unit is in iers mode. As energy consumption is reduced the iers LED flashes at a slower rate. The HFE remains in circuit until the supply is disconnected. The HFE automatically resets and is ready for the next start. Safety Important information Installers should read and understand the instructions in this guide prior to installing, operating and maintaining the soft start. The following symbols may appear in this guide or on the soft start to warn of potential hazards or to draw attention to certain information. Dangerous Voltage: Indicates the presence of a hazardous voltage which could result in personal injury or death. Warning/Caution: Indicates a potential hazard. Any instructions that follow this symbol should be obeyed to avoid possible damage to the equipment, and personal injury or death. Protective Earth (Ground): Indicates a terminal which is intended for connection to an external conductor for protection against electric shock in case of a fault. Caution Statements: The examples and diagrams in this manual are included solely for illustrative purposes. The information contained in this manual is subject to change at any time and without prior notice. In no event will responsibility or liability be accepted for direct, indirect or consequential damages resulting from the use or application of this equipment. Short Circuit: Fairford soft starts are not short circuit proof. After severe overload or short circuit, the operation of the soft start should be fully tested by an authorised service agent HFE soft starts contain dangerous voltages when connected to the mains supply. Only qualified personnel that have been completely trained and authorised, should carry out installation, operation and maintenance of this equipment. Installation of the soft start must be made in accordance with existing local and national electrical codes and regulations and have a minimum protection rating. It is the responsibility of the installer to provide suitable grounding and branch circuit protection in accordance with local electrical safety codes. This soft start contains no serviceable or re-usable parts. 2

59.2 97.5 195 215 228 Mechanical Details MOUNTING The HFE module must be fixed to a vertical surface. To ensure free air movement, a minimum clearance of 40mm must be maintained above and below the unit. 105 135 40.2 40.2 Three off Ø21mm holes for cable glands iers LED Ramp time J1 - iers ON J4 - Refrigeration mode ON 4/T 2/N 1/N 3/L mm 2 1.5-25 AWG 12-4 mm 13 Nm lbs-inch 2 18 mm 0.8x4 4/T 2/N 1/N 3/L Motor Live Motor Neutral Supply Neutral Supply Live Earth/Ground M5 Screw The system may be configured to allow for auto restart controlled from contacts on the motor side of the unit. Users and operators must always take all necessary precautions to prevent damage to equipment and to prevent the risk of injury to personnel working on or near the motor and driven equipment. 3

Electrical Wiring The soft starter is normally inserted into the circuit between the motor and whatever switchgear is normally used for isolation or switching. The unit can also be fitted before switchgear so that it can be installed in the supply to equipment which has its own mechanical control. This feature allows for easy installation on equipment such as refrigeration where the need to disturb internal wiring is avoided. Supply Live Supply Neutral Motor Neutral Motor Live 4/T 2/N 1/N 3/L Note: On some HFE-2 variants, terminals may have alternative markings (see diagram) Supply Live Supply Neutral Motor Neutral Motor Live ML MN N L Neutral Live 110/230Vac Start Cap *Connect Start Capacitor to Supply Live for High Torque or Heavy starting Motor connected for capacitor Start - Run Run Cap Centrifugal or voltage switch controls start Capacitor Extra starting torque may be needed for loads which have a particularly sticky starting characteristic. This can be achieved by rearranging the internal connection of the starting capacitor, bringing the connection out and connecting to the supply side of the starter as shown. The terminations are made with industry standard cage clamp screw terminals directly onto the circuit board on all units. The incoming power supply is connected to the terminals marked 1/N and 3/L. For EMC compliance it is important that the live circuit is connected to 3/L and the neutral circuit to 1/N. Outgoing connections from the HFE are taken from the terminals marked 4/T and 2/N to the motor or load input terminals (see diagram). Ensure that a good connection is made to the earth terminals provided. Fuses or other type of short-circuit protection are required for protection against a cable or motor terminal box fault. These must be fitted externally and on the supply side of the unit. See Specifications section for recommended fuse type and cut-out device. Operation Set the ramp time potentiometer to midway to approx. 2 seconds and start the system. If the motor turns instantly when the soft starter is energised and accelerates satisfactorily then no further adjustment is required. If the rate of acceleration is too great, stop the unit and turn the ramp time potentiometer clockwise then restart. Adjust anti clockwise for a shorter ramp time setting to increase the rate of acceleration. *The motor should turn instantly when the soft starter is energised. If not, rearrange the connection of the starting capacitor as described above. 4

Ratings and Specifications Rating Table Load Amps (Ie) Utilisation Category Start Duty Up to Current (Amps) Time (Secs) Starts/Hr 30 AC53a 90 3 99% 60 IEC Rating Index 30A : AC-53a: 3 3 : 99-60 Specifications Duty Cycle (F-S) 99-10 = 99% duty cycle - 60 cycles/hr Overload Current Profile (X-Tx) 4-3 = 3 times rated current (Ie) for 3s Utilization Category AC-53a = controller semiconductors provide squirrel-cage motor Start, Run, and Stop control Rated Operational Current (Ie) 30A = Rated Operational Current Pedestal Voltage: Start Time: Terminations: Ambient Temperature: Enclosure: Rated Operational Voltage: Recommended cut out device: Rated insulation voltage: Rated impulse withstand voltage: Short circuit co ordination: Fuse Type: Form designation: Pollution Degree: EMC Emissions: EMC Immunity: Design standards: Fixed at ~15%. Continuously variable from 0.5S -5S. Cage clamp terminals suitable for 1.50mm2 (12awg) to 25mm 2 (4 awg) solid or stranded wire 0 C to 40 C without derating. IP20 with standard cover: Ue: 110 to 230V ac ( 15% +10%), 50/60Hz 32A rated MCB, Trip Characteristic C. Form 1 Ui: 250V Uimp: 4kV (1.2 / 50μs) Type 1, Iq: 5kA when protected by recommended Fuse Bussman 170M3113 or Ferraz 6,6 URD 30 D098A 0125 Form 1 2 EN 55011 Environment Class B EN 60947-4-2 IEC 60947 4 2: AC Semiconductor Motor Controllers and Starters. 5

Notes 6

Fairford Electronics Ltd Bristow House Gillard Way, Ivybridge PL21 9GG UK www.fairford.com 7