Bulletin 509 Three Phase Full Voltage NEMA Starters Size 00 (all series) Renewal Parts

Similar documents
Series A Construction

505 Size 5 Series A Construction

Page 1 of 9 Knowledgebase Technote ID # Q /24/2006

700 Type P & PK DC Relays Timer Units Latch Units Series A and B Construction. Renewal Parts

Bulletin 1494M Fixed Depth Remote Operated Disconnect Switches Renewal Parts

Electrically Held to Mechanically Latched Contactor

Allen-Bradley Parts. CENTERLINE 2500 Motor Control Centers Installing, Joining and Splicing Columns. Installation Instructions. Catalog Number 2500

Feeder Circuit Breaker Units Secure Support Pan and Change Door Latch

Installation Instructions. Y-Series Brushless Servo Motor

FULL VOLTAGE STARTERS z SIZE 8 SERIES B CONSTRUCTION

Spare Allen-Bradle. Battery Replacement. Installation Instructions. About This Publication. Catalog Number 2711P-RY2032

IEC Starter Approximate Dimensions

Direct Communication Module

Battery Replacement. Installation Instructions. Summary of Changes. Catalog Number 2711P-RY2032. Original Instructions

Example Maintenance Schedule 1. The attached document is an example of an acceptable maintenance schedule.

Model C230 Pump Controller

Bulletin 109 IEC Non-Reversing Starters. Product Overview/Product Selection. Table of Contents

PowerFlex 7000 AC Drive with Direct-to-Drive Technology. Re-installing a Common Mode Choke Bulletin 7000 Installation Instructions

[V] Common Control Transformer Control (See page 1-78 Note)

CENTERLINE 2500 Low Voltage Motor Control Centers and Power Distribution Gear Catalog Structure Breakdown

J lh. NEMA AC Contactors for Motor Loads (Bulletin 500) and Non-motor Loads (Bulletin 500L) Sizes 0 through 4 (all series), Size 5 (series L)

CENTERLINE 2100 Motor Control Centers

SSR SSR SSR SSR

Enclosed Starter Selection Guide. Featuring Snap-together Wiring Technology

Control and Load Switch Specifications Bulletin Number 194E, 194L

AN RPM to TACH Counts Conversion. 1 Preface. 2 Audience. 3 Overview. 4 References

Medium Voltage Drive Harmonic Filter and Power Factor Correction Units. User Manual. Bulletin volts hp

Installation Instructions. PowerFlex 700 Drive - Frame 8 Components Replacement

Kinetix 350 Single-axis EtherNet/IP Servo Drives

www. ElectricalPartManuals. com GENERAL. ELECTRIC RENEWAL PARTS CR7006-C100, -C101 AND -C102 MAGNETIC STARTERS

USER MANUAL Bulletin 1512A 400A One-High Cabinet Standard and Arc-Resistant Enclosure

NHP SAFETY REFERENCE GUIDE

Installing the Boom Mount ET 350 Monitor (Model ET 350R)

The Complete Range up to 710 kw. Overview Contactors

WELCOME TO THE WORLD OF COMPLETE AUTOMATION. Innovative MCS Starter Solutions. MCS Starters and the New Mounting System 141A

DANGER. Instruction Bulletin WARNING. Shunt Trip Kit for Manual DS/DSL Circuit Breakers POWER ZONE III Low Voltage Switchgear Class 6035 INTRODUCTION

Tattletale Annunciators and Magnetic Switches

Kinetix 300 Single-axis Servo Drives

3-PHASE SMART CONTROLLER STP-SCIIIC INSTALLATION GUIDE

RENEWAL PARTS I C302AA A-2 300V AB A-4800V A C A -SOOOV PARTS RECOMMENDED FOR NORMAL STOCK

Pump Panel Specifications

Relay Retrofit Program Cutting Tool Safety Guide

G3PE-Single-phase. Solid State Relays for Heaters

Product Guide. enclosed NEMA STARTERS

Installation Instructions

Selection Guide for SMC-Delta and SMC-3. A New Dimension in Motor Control

Selection Guide. PowerFlex Digital DC Drive

Bulletin 1609 Industrial Uninterruptible Power Supply (Cat 1609-D)

Kinetix 350 Single-axis EtherNet/IP Servo Drives

4CR SERIES MOTOR STARTING RELAY All Position, Current-Type

Preventive Maintenance Checklist of Industrial Control and Drive System Equipment

A. This Section includes ac, enclosed controllers rated 600 V and less, of the following types:

Updated: October 2012

Industrial Controls. Load Feeder. Configuring SIRIUS Innovations Selection data for Fuseless and Fused Load Feeders. Configuration Manual 04/2011

SINAMICS G130. Motor reactors. Operating Instructions 05/2010 SINAMICS

NEW EQUIPMENT WARRANTY

CD5--- CA4--- CD6---- CB2---- CB4---- PARTS RECOMMENDED FOR NORMAL STOCK

Instruction Bulletin. Jockey Pump Controller

Film Dielectric Trimmers

Selection Guide. Control Circuit and Load Protection

Circuit breaker interlocking and operation requirements SIEMENS

DIESEL EXHAUST FLUID PUMP MOTOR ASSEMBLY REPLACEMENT GUIDE

Kinetix Rotary Motion Specifications

SPC-PANEL Simplex, Single Phase Pump Control Panel

F1-1 ACCESSORIES AND SPARE PARTS FOR DRIWISA EQUIPMENTS INDOOR SERVICE OVERVIEW DRIESCHER Y WITTJOHANN, S.A.

MP-Series Medium Inertia Motors

Slip Ring Connection Board Version 1.0 User s Manual

Generator Start Control Module

Pump Installation and Service Manual HRS Hydromatic Retractable System

TABLE OF CONTENTS. Description Page Description Page. SETI Finland. Approvals:

Industrial Control Transformers

Bulletin 190E/191E Direct On-Line Eco Starters

Electric Motor Controls BOMA Pre-Quiz

Product guide. Enclosed NEMA starters. Answers for industry.

Ø 5 mm Film Dielectric Trimmers

For Options, Modifications and Accessories, see pages Discount Schedule A6

AF series contactors (9 2650)

Aluminum Capacitors +85 C, Large Can

Model GX Spray Gun

Magnetic Overload Relays

Film Dielectric Trimmers

Thermal overload relay TF65 and TF96

THE BULLETIN 509 ASSEMBLY GUIDE - Features and Benefits

MANSI CLS Series LPG/CNG Closed Loop System with Harness and Actuator Motor

Multi-Pak Group Control

Enclosed Molded Case Circuit Breakers

CENTERLINE 2500 Low Voltage Motor Control Centers and Switchgear Assemblies

1370 DC Loop Contactors and Lug Kits

Bulletin 193-T1 Bimetallic Overload Relays

Bulletin 190-M Compact Starters. Selection Guide

Medium Voltage 400A Contactor - Series E and F Allen-Bradley Parts

Relay Retrofit Program for REX 521 Cutting Tool Safety Guide

HV angle valve with single acting pneumatic actuator and closing spring (NC)

NEMA Combination Starter & Enclosed Disconnect Safety Switch Accessories For Field Installation

Types of Motor Starters There are several types of motor starters. However, the two most basic types of these electrical devices are:

Model D Spray Gun. Parts Identification Manual 2943J-ID. "Success through Unity" June 17, 2003 Issue 2 GUSMER CORPORATION

Better Productivity by Standstill and Low-speed Monitoring

Installation, Operating & Maintenance Instructions. All-metal gate valve with compact or extended pneumatic actuator

Type 500X. Electropneumatic Transducer (I/P, E/P) Installation, Operation and Maintenance Instructions. Ordering Information.

DIESEL EXHAUST FLUID PUMPING ACCESSORIES INSTALLATION GUIDE

Transcription:

Page 1 of 7 Knowledgebase Technote ID # Q18318 3/28/2006 Renewal Parts The 509 Three phase starter consists of three switching poles, a fourth pole to be used as a control circuit hold-in contact and overload protection is provided for all three phases. Series A Construction Series B and Series D Construction

Page 2 of 7 Knowledgebase Technote ID # Q18318 3/28/2006 Renewal Parts for Series A Devices Figure 1 is an exploded view of a 509 Size 00 starter the Series A construction. Rewewal Parts for Figure 1 Item Part Description AB Part Number 1 Contact Block with Stationary Contacts X-241076 2 Movable Contact Support with Movable Contacts and Springs X-241534 Movable Contact Support less Contacts and Springs F-20964 3-4 Complete Set of Movable Contacts and Springs Z-21103 5 Insulated Contact Block Screw M-7243 6 Yoke and Armature Assembly Z-31857 7 Relay Left or Right Hand Manual Reset 815-BOV4 (quantity three required) Relay Left or Right Hand Automatic Reset - Main Panel Mounting Plate - Complete Contactor - Operating Coil See coil table Operating Coils for Series A Devices Cat No. Coil AC Coil Part Number Cat No. Coil AC Coil Part Number Volts Hz Series A Volts Hz Series A 6 60 69A21 H 200-208 60 69A113 12 50 69A25 P 220-230 50 69A83 12 60 69A24 F 220 60 69A06 24 50 69A28 A 230-240 60 69A83 J, VJ 24 60 69A27 T 230-240 50 69A83 32 50 69A31 260 50 69A112 32 60 69A30 277 60 69A52 64 50 69A34 Q 440 50 69A288 64 60 69A33 N 380 50 69A11 D 115-120 60 69A86 440 60 69A11 110 50 69A86 B 480 60 69A288 S 110-115 50 69A86 R 550 60 69A16 WE 110 60 69A01 C 550 50 69A81 120 50 69A31 600 60 69A81

Page 3 of 7 Knowledgebase Technote ID # Q18318 3/28/2006 Renewal Parts for Series B Devices Part Description AB Part Number Contactor Contacts for Contactor Power Wiring Kit Main Panel Mounting Plate 599-NAT Eutectic Relay 592-JOV16 Solid State Relay See page 4 Operating Coil See coil table Renewal Parts for Series C Devices There was no bulletin 509 Three phase, size 00, series C construction. The series letter was advanced from Series B to Series D. Renewal Parts for Series D Devices Part Description AB Part Number Contactor 500-TO**930 Contacts for Contactor Power Wiring Kit 105-PW23 Main Panel Mounting Plate 599-NAT Eutectic Relay 592-JOV16 Solid-State Relay See page 5 Operating Coil See coil table ** = Coil Voltage Operating Coils for Series B and D Devices Cat No. Coil AC Volts Hz Coil Repair Part Number Cat No. Coil AC Volts Hz Coil Repair Part Number Series B Series D J 24 60 GA013 J 24 60 TA013 K 24 50 GA407 K 24 50 TA407 D 115-120 60 GA473 D 115-120 60 TA473 110 50 110 50 S 110-115 50 GA473 S 110-115 50 TA473 H 200-208 60 GA049 H 200-208 60 TA049 P 220-230 50 GA474 P 220-230 50 TA474 A 230-240 60 GA474 A 230-240 60 TA474 T 230-240 50 GA442 T 230-240 50 TA442 F 277 60 GA060 F 277 60 TA480 N 380 50 GA454 N 380 50 TA071 KN 380-400 50 GA455 KN 380-400 50 TA071 I 415 50 GA457 I 415 50 TA457 U 415 60 GA069 U 415 60 TA069 Q 440-460 50 GA475 Q 440-460 50 TA475 B 480 60 GA475 B 480 60 TA475 M 500 50 GA464 M 500 50 TA479 R 550 50 GA476 R 550 50 TA476 C 575-600 60 GA476 C 575-600 60 TA476

Page 4 of 7 Knowledgebase Technote ID # Q18318 3/28/2006 Solid-State Relay - For Series B Construction E1 Plus Relay with Automatic/Manual Reset, Field Selectable Trip, 15, 20, or 30, Phase Loss Protection Order the replacement overload relay catalog number from the table below. For example, the E1 Plus overload relay for a 509-TOD-A1A would be ordered as catalog number 592-EEAT. To mount the E1 Plus overload relay, the overload relay panel adapter will need to be replaced. Order part number 193-EPB. The 193-EPB panel adapter is compatible will all of the E1 Plus overload listed in the table below. To mount the E3 Plus overload relay, in place of the SMP-3, the overload relay panel adapter will need to be replaced. Order part number 193-ECPM1. Size Full Load Current Adjustment Range (A) E1 Plus Relay Manual Reset, Phase Loss Protection,, 20, or 30 00 0.1 to 0.32 -A1A 592-EEAT -A2A 592-EEAT -A3A 592-EEAT 00 0.32 to 1.0 -A1C 592-EEAT -A2C 592-EEAT -A3C 592-EEAT 00 1.0 to 2.9 -A1D 592-EECT -A2D 592-EECT -A3D 592-EECT 00 1.6 to 5.0 -A1E 592-EECT -A2E 592-EECT -A3E 592-EECT 00 3.7 to 12 -A1F 592-EEDT -A2F 592-EEDT -A3F 592-EEDT E1 Plus Relay Automatic/Manual Reset, Phase Loss Protection,, 20, or 30 00 0.1 to 0.32 -A4A 592-EEAT -A5A 592-EEAT -A6A 592-EEAT 00 0.32 to 1.0 -A4C 592-EEAT -A5C 592-EEAT -A6C 592-EEAT 00 1.0 to 2.9 -A4D 592-EECT -A5D 592-EECT -A6D 592-EECT 00 1.6 to 5.0 -A4E 592-EECT -A5E 592-EECT -A6E 592-EECT 00 3.7 to 12 -A4F 592-EEDT -A5F 592-EEDT -A6F 592-EEDT E1 Plus Relay with Automatic/Manual Reset, Field Selectable Trip, 15, 20, or 30, Phase Loss, Jam Protection, and Ground Fault Protection. To mount the E1 Plus overload relay, the overload relay panel adapter will need to be replaced. Order part number 193-EPB. The 193-EPB panel adapter is compatible will all of the E1 Plus overload listed in the table below. To mount the E3 Plus overload relay, in place of the SMP-3, the overload relay panel adapter will need to be replaced. Order part number 193-ECPM1. Add catalog numbers 193-EGM or 193-EJM to the E1 Plus catalog number if Ground Fault or Jam Protection is required. The E3 Plus overloads include Ground Fault and Jam Protection, as standard, but must be configured via a DeviceNet network or a hand held programming terminal with a continous power source of 24V DC from a DeviceNet network or a power supply. To mount the E3 Plus overload relay, in place of the SMP-3, the overload relay panel adapter will need to be replaced. Order part number 193-ECPM1. E1 Plus Relay with Automatic/Manual Reset, Field Selectable Trip, 15, 20, or 30, Phase Loss, Jam Protection, and Ground Fault Protection Starter Size Full Load Current Adjustment Range (A) Relay E1 Plus Ground Fault or Jam Module 00 0.1 to 0.32 -B1A 592-EEAT 193-EGM or 193-EJM 00 0.32 to 1.0 -B1C 592-EEAT 193-EGM or 193-EJM 00 1.0 to 2.9 -B1D 592-EECT 193-EGM or 193-EJM 00 1.6 to 5.0 -B1E 592-EECT 193-EGM or 193-EJM 00 3.7 to 12 -B1F 592-EEDT 193-EGM or 193-EJM E3 Plus DeviceNet Relay with Automatic/Manual Reset, Field Selectable Trip, 15, 20, or 30, Phase Loss, Jam Protection, with DeviceNet Communication Capability 00 0.7 to 2.5 -C1D 592-EC2PT (0.4-2.0A) Included as standard or 592-EC2AT (1-5A) 00 2 to 10 -C1F 592-EC2AT (1-5A) or Included as standard 592-EC2BT (3-15A) 00 7 to 37 -C1H 592-EC2BT (3-15A) Included as standard

Page 5 of 7 Knowledgebase Technote ID # Q18318 3/28/2006 Solid-State Relay - For Series D Construction (E1 Plus overload shown below) E1 Plus Relay with Automatic/Manual Reset, Field Selectable Trip, 15, 20, or 30, Phase Loss Protection Order the replacement overload relay catalog number from the table below. For example, the E1 Plus overload relay for a 509-TOD-A1A would be ordered as catalog number 592-EEAT. If the Panel Adapter needs to be replaced, order part number 193-EPB. The 193-EPB panel adapter is compatible will all of the E1 Plus overload listed in the table below. Size Full Load Current Adjustment Range (A) E1 Plus Relay Manual Reset, Phase Loss Protection,, 20, or 30 00 0.1 to 0.32 -A1A 592-EEAT -A2A 592-EEAT -A3A 592-EEAT 00 0.32 to 1.0 -A1C 592-EEAT -A2C 592-EEAT -A3C 592-EEAT 00 1.0 to 2.9 -A1D 592-EECT -A2D 592-EECT -A3D 592-EECT 00 1.6 to 5.0 -A1E 592-EECT -A2E 592-EECT -A3E 592-EECT 00 3.7 to 12 -A1F 592-EEDT -A2F 592-EEDT -A3F 592-EEDT E1 Plus Relay Automatic/Manual Reset, Phase Loss Protection,, 20, or 30 00 0.1 to 0.32 -A4A 592-EEAT -A5A 592-EEAT -A6A 592-EEAT 00 0.32 to 1.0 -A4C 592-EEAT -A5C 592-EEAT -A6C 592-EEAT 00 1.0 to 2.9 -A4D 592-EECT -A5D 592-EECT -A6D 592-EECT 00 1.6 to 5.0 -A4E 592-EECT -A5E 592-EECT -A6E 592-EECT 00 3.7 to 12 -A4F 592-EEDT -A5F 592-EEDT -A6F 592-EEDT

Page 6 of 7 Knowledgebase Technote ID # Q18318 3/28/2006 Solid-State Relay - For Series D Construction (E1 Plus overload shown below) E1 Plus Relay with Automatic/Manual Reset, Field Selectable Trip, 15, 20, or 30, Phase Loss, Jam Protection, and Ground Fault Protection Add catalog numbers 193-EGM or 193-EJM to the E1 Plus catalog number if Ground Fault or Jam Protection is required. If the Panel Adapter needs to be replaced, order part number 193-EPB. The 193-EPB panel adapter is compatible will all of the E1 Plus overload listed in the table below. The E3/E3 Plus s will mount directly to the Bulletin 500 size 00, series D contactor. No panel adapter is required. The E3 Plus overloads include Ground Fault and Jam Protection, as standard, but must be configured via a DeviceNet network or a hand held programming terminal with a continous power source of 24V DC from a DeviceNet network or a power supply. E1 Plus Relay with Automatic/Manual Reset, Field Selectable Trip, 15, 20, or 30, Phase Loss, Jam Protection, and Ground Fault Protection Starter Size Full Load Current Adjustment Range (A) Relay E1 Plus Ground Fault or Jam Module 00 0.1 to 0.32 -B1A 592-EEAT 193-EGM or 193-EJM 00 0.32 to 1.0 -B1C 592-EEAT 193-EGM or 193-EJM 00 1.0 to 2.9 -B1D 592-EECT 193-EGM or 193-EJM 00 1.6 to 5.0 -B1E 592-EECT 193-EGM or 193-EJM 00 3.7 to 12 -B1F 592-EEDT 193-EGM or 193-EJM E3 Plus DeviceNet Relay with Automatic/Manual Reset, Field Selectable Trip, 15, 20, or 30, Phase Loss, Jam Protection, with DeviceNet Communication Capability 00 0.7 to 2.5 -C1D 592-EC2PT (0.4-2.0A) Included as standard or 592-EC2AT (1-5A) 00 2 to 10 -C1F 592-EC2AT (1-5A) or Included as standard 592-EC2BT (3-15A) 00 7 to 37 -C1H 592-EC2BT (3-15A) Included as standard

Important User Information Because of the variety of uses for the products described in this publication, those responsible for the application and use of this control equipment must satisfy themselves that all necessary steps have been taken to assure that each application and use meets all performance and safety requirements, including any applicable laws, regulations, codes and standards. The illustrations, charts, sample programs and layout examples shown in this guide are intended solely for purposes of example. Since there are many variables and requirements associated with any particular installation, Rockwell Automation does not assume responsibility or liability (to include intellectual property liability) for actual use based upon the examples shown in this publication. Allen-Bradley publication SGI-1.1, Safety Guidelines for the Application, Installation and Maintenance of Solid-State Control (available from your local Allen-Bradley office), describes some important differences between solid-state equipment and electromechanical devices that should be taken into consideration when applying products such as those described in this publication. Reproduction of the contents of this copyrighted publication, in whole or part, without written permission of Rockwell Automation, is prohibited. Throughout this document we use notes to make you aware of safety considerations: ATTENTION Identifies information about practices or circumstances that can lead to personal injury or death, property damage or economic loss! IMPORTANT Identifies information that is critical for successful application and understanding of the product. Use only replacement parts and devices recommended by Rockwell Automation to maintain the integrity of the equipment. It is the user s responsibility to ensure that the renewal part number selected is properly matched to the model, series and revision level of the equipment being serviced. ATTENTION! Servicing energized Industrial Control Equipment can be hazardous. Severe injury or death can result from electrical shock, burn, or unintended actuation of controlled equipment. Recommended practice is to disconnect and lockout control equipment from power sources, and release stored energy, if present. Refer to National Fire Protection Association Standard No. NFPA70E, Part 2 and (as applicable) OSHA rules for Control of Hazardous Energy Sources (Lockout/Tagout) and OSHA Electrical Safety Related Work Practices for safety related work practices, including procedural requirements for lockout/tagout, and appropriate work practices, personnel qualifications and training requirements where it is not feasible to de-energize and lockout or tagout electric circuits and equipment before working on or near exposed circuit parts. ROCKWELL DISCLAIMS ALL WARRANTIES WHETHER EXPRESSED OR IMPLIED IN RESPECT TO THE INFORMATION (INCLUDING SOFTWARE) PROVIDED HEREBY, INCLUDING THE IMPLIED WARRANTIES OF FITNESS FOR A PARTICULAR PURPOSE, MERCHANTABILITY, AND NON-INFRINGEMENT. Note that certain jurisdictions do not countenance the exclusion of implied warranties; thus, this disclaimer may not apply to you. Allen-Bradley is a trademark of Rockwell Automation