NEMA Pump Controls. Class 82 slim line NEMA pump controller for the agricultural industry

Similar documents
NEMA Pump Controls. Class 82 slim line NEMA pump controller for the agricultural industry

NEMA Pump Controls Class 82 slim line NEMA pump controller for the agricultural industry Answers for industry.

Controls Express. A wide selection of enclosed NEMA controls now available with faster shipping as a standard. Fast. Easy.

Product Guide. NEMA pump controls.

Product guide. Enclosed NEMA starters. usa.siemens.com/controls

Product guide. Enclosed NEMA starters. Answers for industry.

Product Guide. enclosed NEMA STARTERS

ECN A A A - B - C - D - E - F - A - B - C - D - E - F - NEMA Size 5 - Size Size Size Size Size 9

SECTION MOTOR CONTROL

Controls Express. A wide selection of enclosed NEMA controls now available with faster shipping as a standard. Fast. Easy. Reliable.

Product Specification Sheet #3LD2.1

Controls Express. A wide selection of enclosed NEMA controls now available with faster shipping as a standard. Fast. Easy.

Electropneumatic Timing Relays Series 7000 Industrial

AF40... AF96 3-pole contactors Technical data

Short form catalogue. Motor protection & control

B115...B180 RF200 RFN200 B250...B400 RF400 RFN400

NEMA Contactors & Starters (Freedom)

Controls Express. A wide selection of enclosed NEMA controls now available with faster shipping as a standard. Fast. Easy. Reliable.

The Enclosed Altistart 22 Soft Start/Soft Stop Motor Controller

Enclosures. See Section Typical Description

Thermal Overload Relays

Bulletin 1494F Fixed-Depth Flange-Mounted Disconnect Switches. Selection Guide

Controls Express. A wide selection of enclosed NEMA controls now available with faster shipping as a standard. Fast. Easy. Reliable.

MS General Information Extended Product Type: MS

AF40... AF96 3-pole contactors 30 to 60 hp at 480 V AC AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts

Design Guide for Integration of Fixed-Mount Circuit Breakers

Instruction sheet WARNING. October, 2014

600V, Non-Fusible, (3-Pole, 3 Phase)

Well-Guard Control. Pumping Plant Panels. Catalog 8940CT9701R11/ Class 8940

EPS-ECONOMY PUMP STARTER

Softstarters Type PSS. Softstarters. General information

GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Standard Features

AF09... AF30 3-pole Contactors up to 25 HP / 600 VAC

Transfer switch OTEC open or delayed transition

3. Coils shall be of molded construction

1.2. Reduced Voltage Motor Starters. Contents Description Type S611, Solid-State Soft Starters... Type S801+, Soft Starters. Solid-State Starters

Multi-Pak Group Control

I r A short-circuit protective device: Observe the maximum permissible fuse of the contactor with direct device mounting.

50,000 cycles minimum, resistive, inductive, tungsten filament lamp load (Fed Spec) 1.753" Depth x " Width x 2.375" Height

Application Description

CONTACTOR, AC-3 15 KW/400 V, AC 110V 50HZ/120V 60HZ 3-POLE, SIZE S2, SCREW CONNECTION. General technical data: Main circuit: product brand name

Midwest Electric Products. Safety Switches Rugged, reliable and easy to install

PATTERSON PUMP COMPANY

MS /27/2015. ABB contact for United States of America. General Information Extended Product Type: Categories

Bussmann series Quik-Spec Coordination Panelboard

Vigilant Automatic Transfer Switches

Quik-Spec Electrical Gear

1 3RT1016-1A**1 1 3RT1017-1A** RT1025-1A** RT1025-3A** RT1034-1A** RT1034-3A**0 175.

Submittal Data Information

4.4. Definite Purpose Contactors and Starters A Starters A27, B27. NEMA Type 1 Enclosed Control

DATASHEET - ZB Delivery program. Overload relay, 50-65A, 1N/O+1N/C. Catalog No Eaton Catalog No. XTOB065DC1 EL-Nummer

1.2. Reduced Voltage Motor Starters. Contents Description Type S611, Soft Starters... Type S801+, Soft Starters. Type S801+, Soft Starters

Enclosed Full-Voltage Starters

Selection Guide Motor Control Device Solutions

Manual Motor Starters. Meta-MEC

D2P and EWP Factory Sealed Circuit Breaker Panelboards Explosionproof, Dust-Ignitionproof, Watertight, Corrosion-Resistant

Non-Fused Load Break Switches FSSC, SX, SXDC, SC

Thermal overload relays Type TA Class 10

Model 550 Series Vibration Switches

2000 Series Geared Rotary Limit Switches

Star Series Motor protection & control

ESW/PESW. Non-Combination Starters

AF / AF12Z pole Contactors AC / DC Operated - with Screw Terminals

SECTION PANELBOARDS

AF09... AF30 3-pole Contactors up to 20 HP / 480 VAC

Bulletin 1494V Variable Depth Flange-Mounted Disconnect Switches. Bulletin 1494F Fixed-Depth Flange-Mounted Disconnect Switches

NEMA Vacuum Break Contactors and Starters

Non-Fused Load Break Switches FSSC, SX, SXDC, SC

General information about motor protection

General technical data. Ambient conditions

Ideal for use as a manual starter

Electromechanical Level Control

AF / AF38Z pole Contactors AC / DC Operated - with Screw Terminals

Disconnect Switches Type VBII (30-600A) with Flange Mounted Operating Handle

Lighting and Heating Control

3.1. NEMA Manual Starters. Contents Description Types B230, B330, Switches... MS Series, Single-Phase Starters...

Safety switches for hinges

Enclosed Full-Voltage Starters

Compact Circuit Protector

AF / AF30Z stack 3-pole Contactors AC / DC Operated - with Screw Terminals

BAC Custom Engineered Controls

Meta Solution. Contactors and Overload relays

SUBSTATION VACUUM CIRCUIT BREAKER (38KV)

SUBSTATION VACUUM CIRCUIT BREAKER (15.5KV)

SUBSTATION VACUUM CIRCUIT BREAKER (25.8 / 27KV)

AF / AF16Z pole Contactors AC / DC Operated - with Screw Terminals

TDX - Taco Duplex Starter with

ASL09..S 3-pole Contactors - Spring Terminals

AM-Tite Series Non-Metallic Plugs MSR Series Switched and Interlocked Receptacles

Horsepower Ratings 240V AC 1 Phase, 2 Phase, 3 Phase, Ampere Catalog List Ship Wt.* Catalog List Ship Wt.* Indoor Type 1 Outdoor Type 3R

FMotor Circuit Controllers

Air Conditioning Disconnects

Installation Sheet January, 2016 Supersedes February, 2013

General technical data: CONTACTOR, AC-3, 11KW/400V, 1NO+1NC, AC110V 50HZ, 120V 60HZ 3-POLE, SZ S0 SCREW TERMINAL. product brand name

Softstarters. Softstarters Power electronic brakes Type PEB

HKH Series. HAZCON Controls for Harsh and Hazardous Environments

Design Standard. Purpose: Design Standard:

Motor Starters. Reduced Voltage. Reduced Voltage Motor Starters 1. Contents

General and Heavy Duty Safety Switches

MAx-305 & MAx-318 Series MAx-405 Through MAx-419 Series Two-Position Actuators

Transcription:

NEMA Pump Controls Class 82 slim line NEMA pump controller for the agricultural industry See NEW preliminary information on Class 82 size 1 in an extra wide enclosure and size 2 standard enclosures. www.usa.siemens.com/controls

Class 82 Slim Line NEMA Pump Controller Siemens introduces its new Class 82 slim line NEMA Pump Panel. This newest addition to the already extensive line of Siemens pump panels was designed specifically for the agricultural market. It is well suited for irrigation and similar pumping applications and is built to withstand the harsh elements of the outdoors. Why you should use the Class 82 Pump Panel Simplicity and its compact lightweight design makes this an attractive solution to your budgeting challenges. The contactor is NEMA rated to provide reliable motor control and protection expected in the most demanding applications. The ESP200 solid-state overload relay has a protective coating on the circuit board which gives it superior protection against high humidity, condensation and corrosive environments. Its size and weight is about half that of the Class 87 which increases the ease of installation. Typical applications include: Crop irrigation Sprinklers, misters and soakers Watering for livestock and other dairy applications Ground dewatering for excavation and construction sites 2 Product Selection Max Hp Rating Motor Voltage 230 460 NEMA Size Overload Relay Amp Range Coil Table Voltage 110VAC 50HZ / 120VAC 60HZ 220VAC 50HZ / 240VAC 60HZ 480VAC 60HZ Disc. Amp Rating Fuse Clip Amp/Volts HOA & Start Push Button Catalog Number Letter HOA & Start Push Button (Extra wide Enclosure) Catalog Number 1 1 0.75 3.4 30 30A/600V 82ADB6FB* 82BDB6FB* 5 1 3 12 30 30A/600V 82ADC6FB* 82BDC6FB* 10 1 5.5 22 30 30A/600V 82ADD6FB* 82BDD6FB* F G a H b Accessories Image Description Part Number 3/4" Type 3R Conduit Hub ECHS075 1" Type 3R Conduit Hub ECHS100 1 1/4" Type 3R Conduit Hub ECHS125 1 1/2" Type 3R Conduit Hub ECHS150 Disconnect Switch Auxiliary Contacts 2 NO/2 NC DPDT (NEMA A600) HA261234 Fuse Puller Kit For 30A Switch (1 kit required per switch) HP61 30A, 240V Class R Fuse Clip Kits HR21 30A, 600V; 60A 240V Class R Fuse Clip Kits HR612 60A, 600V Class R Fuse Clip Kits HR62 2 1 3 12 30 30A/250V 82ADC6FA* 82BDC6FA* 3 1 5.5 22 30 30A/250V 82ADD6FA* 82BDD6FA* 7 1/2 1 10 40 30 30A/250V 82ADE6FA* 82BDE6FA* 25 2 13-52 60 60A/600V 82AFF6FD* --- 15 2 13-52 60 60A/250V 82AFF6FC* --- Replace the (*) with a letter from the coil table. a G coil is not available with a 600v disconnect b H coil is not available with a 250v disconnect Contactor Auxiliary Contacts, Side Mounted 1 NO/NC (NEMA A300/Q300) ESP200 Tamper Resistance Cover 3RH29111DA11 49ASTC1 2

Features and Benefits A Compact and light-weight NEMA type 3/3R enclosure for ease of installation. Fabricated with galvanized steel versus conventional cold rolled steel for superior corrosion resistance. B Two lockable latches to tightly seal door. C Drip shield to help prevent water entry. D Pole straps at top and bottom of enclosure for easy mounting on poles or flat surfaces using keyhole slots. E Rugged metal handle with lock-out provision for durability. C D E A B 9.5 Class 87 22 24-60% 20 3

Title Category Features and Benefits G H F Metal 30 mm H-O-A switch and Start push button are water and dust tight. G Full gasketed door to ensure a dust tight and water tight seal. H Pre-punched opening with cover plate for convenient field installation of a conduit hub should top entry be required. I Multiple conduit knockouts for convenient field installation of conduit should bottom entry be required. J Heavy-duty disconnect switch with line-side shield and visible blades for safety and double break switch action to reduce arcing and increase lifetime. K NEMA rated contactor to provide reliable motor control and protection expected in the most demanding applications. L ESP200 solid-state overload relay with protective coating on circuit board which gives it superior protection against high humidity, condensation and corrosive environments. M 3-point terminal strips, as standard, for convenient field connections N 3-point ground lug. L K M I J N F 4

Nomenclature 82 A D C 6 F B H Series A = Standard size enclosure B = Extra large enclosure (starter size 1 only) Starter Starter Size Size D = D 1= 1 F = 2 OLR OLR Current Current Range Range B = B 0.75 = 0.75-3.4A - C = 3-12A C = 3-12A D = 5.5-22A D = E 5.5 = 10-40A - 22A E = F 10 = 13-52A - 40A Cover Control 6 = 4 HOA = HOA selector selector switch switch with only Start push button 6 = HOA selector switch with Start push button Disconnect Type Disconnect F = Fusible Disconnect Type F = Fusible Disconnect Disconnect & Fuse & Fuse Clip Clip Rating Rating A = 30A/250V A = 30A/250V B = 30A/600V B = 30A/600V C = 60A/250V D = 60A/600V Coil Voltage Coil Voltage G = 220VAC 50Hz / 240VAC F = 60Hz 110VAC 50HZ / 120VAC 60HZ G = 220VAC 50HZ / 240VAC 60HZ H = 480VAC 60Hz H = 480VAC 60HZ 5

Technical Data General Technical Data: Weight Height x Width x Depth Maximum altitude Ambient (outside enclosure) storage temperature Ambient (outside enclosure) operating temperature Country of origin Size 1 (Standard Encl.) 23lbs. Size 1 (Extra Wide Encl.) 47lbs. Size 2 (Standard Encl.) 47lbs. Size 1 (Standard Encl.) 26 x 12 x 5in. Size 1 (Extra Wide Encl.) 35 x 17 x 6in. Size 2 (Standard Encl.) 35 x 17 x 6in. 6560 ft. (-30 to 65) C / (-22 to 149) F (-20 to 40) C / (-4 to 104) F Mexico Horsepower Rating: See selection table above Contactor: Number of NO main contacts Amp rating Mechanical operating cycles Internal / Standard Auxiliary Contact Number of NC / NO auxiliary contacts NEMA contact rating designation Optional auxiliary contacts available Coil: Voltage Apparent pull-in / holding power Normal coil operating limits (% of rated voltage) Pick-up time / Drop-out time Overload Relay: Current range Trip Class Trip detection Phase failure sensitivity Repeat accuracy Reset options External reset Test function Conformal coating on printed circuit board Number of NC / NO auxiliary contacts Rating of auxiliary contacts Single contact isolation Dual contact isolation 6 Disconnect Switch: Rating Fuse type accepted Enclosure: Type Rating Standard Control Devices: Hand-Off-Auto selector switch Start push button Mounting / Wiring: Mounting orientation Mounting type Disconnect line side connection type / torque Disconnect line side solid and stranded conductors Power terminal block connection type / torque Power terminal block solid and stranded conductors Control terminal block connection type / torque Control terminal block solid and stranded conductors Coil connection type / torque Coil solid and standed conductors Main auxiliary contact connection type / torque Main auxiliary contact solid and stranded conductors OLR auxiliary contact connection type / torque OLR auxiliary contact solid and starnded conductors See selection table above 3 32A, 50A 10,000,000 1NC / 1NO A600 AC / Q600 DC Yes 220/230V 50/60Hz, 460V 60Hz, or 110/120V 50/60Hz 81 VA / 10.5 VA 80% - 110% at 60Hz 8-40 / 4-16 msec 0.75-3.4 or 3-12 or 5.5-22 or 10-40 Amps or 13-52 Amps Class 5 / 10 (factory set) / 20 / 30 Overload, phase failure, phase unbalance, ground fault Trip time after phase loss: < 3 sec Within 1% Manual, automatic and remote Yes Electronics and manual actuation Yes 1NC /1NO B600 AC / R300 DC 600 V 300 V differing polarity / 600 V common polarity 30 A with 30A/600 or 30A/250 V Class H fuse clips 60 A with 60A/600 or 60A/250 V Class H fuse clips Class H, J or R NEMA Type 3/3R enclosure Weather proof for outdoor use 3SU1 30mm, round, metal with matte finish 3SU1 30mm, round, metal with matte finish Vertical Pole and surface Box lug / 35 lb in (14-10); 40 lb in (8); 45 lb in (6-4) AWG 1x(14-2 AWG) 60/75 C AL or CU Screw / 24-32 lb - in 1x(18-2 AWG) 75 C CU Screw / 12-18 lb - in 1x(22-8 AWG) 75 C CU Screw / 7-10 lb in 2x(16-12 AWG) CU 60/75 C Screw / 7-10 lb in 2x(20-16), 2x(18-14) 75 C CU Screw / 7-10 lb in 2x(20-14 AWG) CU 60/75 C Short Circuit Current Rating: Fuses 10kA@600V (Class H or K); 100kA@600V (Class R or J) Certificates / Approvals: culus UL rated Service Entrance Equipment UL (file no. E185287) ISO 9001 certification

Size 1 (Standard width enclosure).25 2.75 5.57 1/4-20 x1/2" SCREW 2.88 3.50 3.50 10.93 3.06 2.88 3.50 3.50 1.68 24.27.37 2.13 1.81 25.00 2.85 O.D. FLANGED 26.13 CONDUIT OPENING 1.375, 1.700, 2.000, 2.500 MOUNTING HOLES FOR ECCENTRIC KNOCKOUT 5/16" HARDWARE 1.125, 1.385, 1.750, 2.000 5.02 ECCENTRIC KNOCKOUT (2 PLACES) 5.08 ALL DIMENSIONS IN INCHES START BUTTON HAND-OFF-AUTO SELECTOR SWITCH Size 1 (Extra wide enclosure), Size 2 (Standard width enclosure) TO SUPPLY L1 L2 L3 DISCONNECT LEGEND - FIELD WIRING - TERMINAL ON COMPONENT - LOAD\CONTROL TERMINAL BLOCK POINT LINE FUSES 1L1 M 2L1 OLR T1 1L2 2L2 T2 MOTOR 1L3 2L3 T3 OFF HAND AUTO START PB OLR M ( A1) (A2) (95) (96) SS (14) M (13) AUTO RUN AUTO 4 5 STOP 6 (21) M AUXILIARY CONTACTS (22) (97) OLR (98) REMOVE JUMPER FOR AUTO - STOP 7

Siemens Industry, Inc. 100 Technology Drive Alpharetta, GA 30005 1-800-241-4453 info.us@siemens.com Subject to change without prior notice Order No. CPBR-CLS82-0117 Printed in USA All rights reserved 2017, Siemens Industry, Inc. Subject to changes and errors. The information given in this document only contains general descriptions and/or performance features which may not always specifically reflect those described, or which may undergo modification in the course of further development of the products. The requested performance features are binding only when they are expressly agreed upon in the concluded contract.