USERS GUIDE LO-21U LOCKOUT RELAY

Similar documents
USERS GUIDE BODYGUARD III SMR PRESENCE SENSOR

QUADSCAN User s Guide Door Mounted Presence sensor

BODYGUARD III-C USER S GUIDE

ASSA ABLOY. 7100SZ Series SafeZone External Sensor. Installation and Instruction Manual ASSA ABLOY. Patent Pending

Setup and Programming Manual

Door Position System USER S GUIDE

Senior Swing Control Box. Table of Contents

Door Position System USER S GUIDE

INSTALLATION MANUAL. Model: PLUS For Technical Assistance, please call (800) , or visit

INSTALLATION MANUAL. Model: PLUS Vehicle Security

Vehicle Security System

INSTALLATION MANUAL. Remote Mobile Security System. Model: PL50

INSTALLATION MANUAL. Remote Mobile Security System. Model: PL30

SW10 (Full Power) & SW19 (Low Energy)

INSTALLATION GUIDE For Surface Mounted Applications (Purchased after 08/01/2018)

B100S - Super Swing. Instruction Manual. Document number: B100S-C Release: V4.0 Date: May 08,2009

B-PC20 Power Close Module

SERIES 700/700E FACTORY KEYLESS UPGRADE INSTALLATION MANUAL

Automatic Sliding Door Retrofit Drive Assembly. Installation Manual DoorControlsUSA.com

Swing Door Door Mounting Sensor

Installing the gate post bracket with the cardboard arm template

INSTALLATION GUIDE Table of Contents

Gate & Door Controller with LCD and Intelligent Technology

What s on your truck? MOTIONACCESS, LLC. Installation & Operation Manual

Easy Start. 364 (3 ton) Soft Starter 368 (6 ton) Soft Starter. Installation Manual

Flight Systems. Replacement for KASSEC DESCRIPTION

MM1 Installation Instructions

LED Reference for Circuit Board

U S A INSTALLATION GUIDE EP400 / E8-B

Installing the gate post bracket with the cardboard arm template

Remote Start with Keyless Entry Installation Guide CA 5051

12V PROGRAMMABLE POWER OUT

Vehicle Security System

CS-865RKE Series II REMOTE KEYLESS ENTRY SYSTEM

Installation Instructions & Users Manual

GLM SERIES CONTROL Users Manual Rev:

CM4200 and CM1000S Starter Control Module Installation Manual

Automatic / Manual Transmission Remote Start with Keyless Entry Installation Guide for models: ca5153 ca5153sst

7100SZ Series SafeZone Installation and Instruction Manual

2 WAY REMOTE STARTER & ALARM SYSTEM INSTALLATION GUIDE FCC ID NOTICE

MSD 7AL-3, Ignition Control PN 7230

MD10. Engine Controller. Installation and User Manual for the MD10 Engine Controller. Full Version

Remote Start with Keyless Entry Installation Guide ca5054

PAGE. 20. Connecting an intercom.

Vehicle Security System

INSTALLATION GUIDE. FCC ID NOTICE

Security and Keyless Entry Installation Guide ca 1051

Installation Instructions

3 Channel Remote Start / Keyless Entry System Installation Instructions

Button 1 Button 2. Button 3 Button 4. Programmed Remote Transmitter. Button Function Condition

Service Manual Gulf Stream Electronic Full Wall Slide Systems

APOLLO Gate Operators, Inc.

CS-2000 Series III REMOTE CONTROL ALARM SYSTEM INSTALLATION & OPERATING INSTRUCTIONS

Installer Instructions

Shaved-B. Installation Manual & Operation Instructions

DTS 412/512/624 SLIDING GATE MOTOR INSTALLATION MANUAL

535T Window Automation System

DLKEK3HN INSTALLATION INSTRUCTIONS

PROFESSIONAL INSTALLATION STRONGLY RECOMMENDED

CA-510a Installation Instructions

FM SECURITY AND REMOTE START SYSTEM

COMMANDO REMOTE CONTROL ENGINE STARTER. Limited Warranty Statement MADE IN THE U.S.A. IMPORTANT KEEP YOUR INVOICE WITH THIS WARRANTY STATEMENT!

CSI-300 Installation Instructions

REC-11+ REMOTE RECEIVER UNIT

SYMBOL LEGEND DANGER WARNING NOTE THIS INDICATES DANGER TO THE LIFE AND HEALTH OF THE USER IS APPROPRIATE PRECAUTIONS ARE NOT TAKEN

AS-4000 OPERATING INSTRUCTIONS (PS-5000)

2 Way Security and Keyless Entry Installation Guide ca 1553

POWERLINE 2000 Energy Management System TM

TELEPHONE TECHNICAL SERVICES DS5 USER GUIDE

Model PRO 9246CH Installation Manual

CA 421 Installation Instructions

Water Valve Shutoff. WVS Water Valve Shutoff

Roll Up Door Operator

Auto-Level Troubleshooting (Old Platform) Electronic Control- Prior to 2009, Pressure Switch Control panel #s 2057, 2058, 2795, 2795B

INSTALLATION GUIDE OWNER S GUIDE

AviStart 6500 Installation Manual

CSI-100 Installation Instructions

CS-2004 WDC. Remote Control Alarm System with CoolGlow & SecurWatch INSTALLATION & OPERATING INSTRUCTIONS

Model 2100 Installation Guide

PCS 100 SYSTEM INSTALLATION INSTRUCTIONS

Automatic / Manual Transmission Remote Start with Keyless Entry Installation Guide. ca 5152

30A SMART ENERGY MANAGEMENT SYSTEM TM

6R / 5-BUTTON SERIES VEHICLE SECURITY SYSTEM

CS-2000 Series III REMOTE CONTROL ALARM SYSTEM INSTALLATION & OPERATING INSTRUCTIONS INTRODUCTION

CB CONTROL BOARD INSTRUCTION MANUAL VERSION 1.03 DATE 30/10/2000

Advanced Remote Vehicle Starting System

BZ-150. Installation Instructions. Power Pack SPECIFICATIONS

CS-2001 REMOTE CONTROL ALARM SYSTEM INSTALLATION & OPERATING INSTRUCTIONS INTRODUCTION

Vehicle Alarm System With Channel 2 Auxiliary Output Installation Instructions

Vertical Vinyl Curtain Door

OnCommand Troubleshooting Guide Hayward Industries

VS 315 DELUXE 4-CHANNEL MOTORCYCLE ALARM. Installation And Operation Manual MEGATRONIX CALIFORNIA, U.S.A. VS 315 1

Service/Installation Manual Full Wall Slide Systems CONTENTS. 82-S0379 Rev 3. Page. Before you operate the slide system 2

SST-3 Start-Stop-Throttle

QUICK INSTALLATION GUIDE

CORESENSE DIAGNOSTICS FOR STREAM REFRIGERATION COMPRESSORS

OCT/21/02 MEGA 670L DELUXE 4-CHANNEL CAR ALARM SECURITY SYSTEM. Installation And Operation Manual MEGATRONIX CALIFORNIA, U.S.A.

Reproduction or other use of this Manual, without the express written consent of Vulcan, is prohibited.

INSTALLATION MANUAL 601-S INFORMATION.) 8. REMOVE DOME LIGHT FUSE TO PRE- VENT BATTERY DRAIN.

Transcription:

USERS GUIDE LO-21U LOCKOUT RELAY PRODUCT DESCRIPTION The LO-21U (PN: 10LO21U) is a micro-processed lock out module designed to operate on swing door applications with BEA s Bodyguard or DK-12 overhead presence sensor. The LO-21U interprets door open or door closed position based upon motor voltage input. The motor voltage information is sent from the LO-21U to the Bodyguard or DK-12 via data lines. The LO-21U provides optional safety beam input (dry contacts) to override the inhibit signal during closing. TECHNICAL SPECIFICATIONS DESCRIPTION Supply voltage Operating frequency Power consumption Output Maximum voltage Relay contacts Maximum current Relay contacts SPECIFICATION 12 to 24 VAC / 15 to 24 VDC 4 MHz (Microprocessor) 10 ma at rest, 50 ma Maximum (2) SPST Relays 60 VDC, 120 VAC 2A DC, 0.5 A AC COMPONENT ID Green LED Dipswitches Red LED SAFETY PRECAUTIONS Shut off all power going to the header before attempting any wiring procedures. Maintain a clean & safe environment when working in public areas. Constantly be aware of pedestrian traffic around the door area. Always stop pedestrian traffic through the doorway when performing tests that may result in unexpected reactions by the door. Always check placement of all wiring before powering up to insure that moving door parts will not catch any wires and cause damage to equipment. Ensure compliance with all applicable safety standards (i.e. ANSI A156.10) upon completion of installation. 75.1041.08 LO21U 20150708 Page 1 of 5

WIRING INSTRUCTIONS 1. Wire the LO-21U according to the chart below. All LO-21 wiring must be accomplished with the module unplugged. If the red / white striped and white wires (data wires) touch each other when power is applied, damage to the unit will result. WIRE COLOR CONNECTION POINT Black Motor (-) Red Motor (+) Violet Bodyguard Pin 3 (Common) White Bodyguard Pin 6 (Data - ) Black / White Safety Beam (Common) Orange Power (-) / 12 to 24 volts AC/DC Gray Bodyguard Pin 4 (N/O) Red / White Bodyguard Pin 7 (Data +) and Safety Beam (N/O) Brown Power (+) / 12 to 24 volts AC/DC Green Door Control (Common) Blue Door Control (Activate) Yellow Door Control (Safety) APPROACH SIDE SAFETY SIDE POWER 8 POWER 7 COM 6 N.O. 5 N.C. 4 INHIBIT + 3 INHIBIT GND 2 BLANK 1 POWER 8 POWER 7 COM 6 N.O. 5 N.C. 4 INHIBIT + 3 INHIBIT GND 2 BLANK 1 115 VAC 24 V TRANSFORMER SAFETY BEAM INPUT DRY CONTACTS BLACK/WHITE RED/WHITE WHITE ORANGE BROWN LO21U GREEN YELLOW BLUE DOOR CONTROL STALL/ STOP-n- HOLD COMMON SAFETY ACTIVATION BODYGUARD DATA + 7 DATA - 6 GRAY VIOLET BLACK RED - + MOTOR VOLTAGE DK-12 N.C. 5 N.O. 4 COM 3 POWER 2 POWER 1 MOTOR 1 PWR 2 PWR 3 COM 4 N/O 5 N/C EAGLE DIPSWITCH SETTINGS 1. The dipswitches are located at the end of the LO-21U, opposite of the wire connection terminal. There are 8 positions available. Dipswitch designations are as follows: OFF Default settings shown. 1 2 3 4 5 6 7 8 ON 75.1041.08 LO21U 20150708 Page 2 of 5

Dipswitch # Function OFF ON 1 Time Delay: 1 sec. value 0 seconds 1 second 2 Time Delay: 2 sec. value 0 seconds 2 second 3 Time Delay: 4 sec. value 0 seconds 4 second 4 Time Delay: 8 sec. value 0 seconds 8 second 5 Time Delay: 16 sec. value 0 seconds 16 second 6 Voltage switching device Voltage source is other than motor Motor Voltage 7 Safety circuit logic (used with DS #8) 7 OFF / 8 ON = N/O Safety Circuit 8 Safety circuit logic (used with DS #7) 7 ON / 8 OFF = N/C Safety Circuit DIPSWITCH SETTINGS Cont. 2. Use the chart (at right) for a quick-reference for time delay settings (switches 1 through 5). Factory setting is 7 seconds. Example: The normal closing cycle of an automatic door lasts about 7 seconds. In order to get the proper closing lock out time delay needed for the closing cycle of the door, the dipswitches need to be set according to the chart on page 3 for 7 seconds. To get the proper lock out time delay dip switches 1, 2, & 3 must be in the ON position and Dip Switch 4 must be in the OFF position. Seconds dip 1 1 sec dip 2 2 sec dip 3 4 sec dip 4 8 sec dip 5 16 sec 1 ON OFF OFF OFF OFF 2 OFF ON OFF OFF OFF 3 ON ON OFF OFF OFF 4 OFF OFF ON OFF OFF 5 ON OFF ON OFF OFF 6 OFF ON ON OFF OFF 7 ON ON ON OFF OFF 8 OFF OFF OFF ON OFF 9 ON OFF OFF ON OFF 10 OFF ON OFF ON OFF 11 ON ON OFF ON OFF 12 OFF OFF ON ON OFF 13 ON OFF ON ON OFF 14 OFF ON ON ON OFF 15 ON ON ON ON OFF 16 OFF OFF OFF OFF ON 17 ON OFF OFF OFF ON 18 OFF ON OFF OFF ON 19 ON ON OFF OFF ON 20 OFF OFF ON OFF ON 21 ON OFF ON OFF ON 22 OFF ON ON OFF ON 23 ON ON ON OFF ON 24 OFF OFF OFF ON ON 25 ON OFF OFF ON ON 26 OFF ON OFF ON ON 27 ON ON OFF ON ON 28 OFF OFF ON ON ON 29 ON OFF ON ON ON 30 OFF ON ON ON ON 31 ON ON ON ON ON 3. DIPSWITCH #6: Corresponds to the type of motor voltage logic on the RED and BLACK wires. Dipswitch 6 should be on for all applications that have the red and black wires going to a parallel motor connection. Dipswitch 6 should be OFF for applications where voltage is present on the red and black wires at the closed door position, and where 0 volts is present at the door open position. 4. DIPSWITCH 7 OFF & 8 ON: Provides a CLOSED circuit between the GREEN (COMMON) and YELLOW (SAFETY) during BODYGUARD detection and an OPEN circuit at all other times. 5. DIPSWITCH 7 ON & 8 OFF: Provides a OPEN circuit between the GREEN (COMMON) and YELLOW (SAFETY) during BODYGUARD detection and a CLOSED circuit at all other times. (Example: Besam PowerSwing). Brand / Model Of Operator Besam Swingmaster (ETIK) Besam Swingmaster MP (CUP) Besam PowerSwing Doromatic Astro-Swing Mid-Swing Senior Swing Gyro-Tech (all except Gemini 710 AND U11) Horton 4000 Horton 7000 KM 2000 Stanley Magic Swing Magic Force (with safety) Dipswitch 6, 7 & 8 Setting 6 OFF 7 OFF, 8 ON 6 ON, 7 ON, 8 OFF 75.1041.08 LO21U 20150708 Page 3 of 5

SET-UP INSTRUCTIONS The following instructions pertain to the setup procedures and the related indications that should be observed. RED LED Bodyguard s output is Applied to the safety circuit GREEN LED Bodyguard s output is Applied to the activation circuit Set the dipswitches according to the chart below to achieve the desired lock out time delay. Immediately following each step, is a corrective action to perform if the step does not pass: 1. Set the On-Off-Hold Open switch to the OFF position. If a switch is not available, unplug the activating device for the door. 2. To begin the set-up, apply power to the door system, to the LO-21U module, and to the Bodyguard. The Bodyguard shall immediately begin flashing green to indicate a setup for the closed door position. q If the Bodyguard does not begin flashing green, check to insure it is receiving the correct power at inputs 1 & 2 at the 7-position terminal at the left side of the Bodyguard. Correct as necessary. 3. Do not enter into the field of detection while the Bodyguard is setting up. After approximately 6 seconds, the green LED will expire. 4. Activate the door to the open position with the On-Off-Hold Open switch, or by jumpering the activate circuit. The Bodyguard shall begin flashing green again while it is learning the door open set-up. Again, approx. 6 seconds of un-interruption will allow a setup to complete. Once complete, the door should begin to close if activation is removed. Place the On-Off-Hold Open switch to the On position. Normal operation thereafter. q If the Bodyguard does not begin flashing green when the door reaches full open, improper voltage may exist on terminals 6 & 7 of the Bodyguard. Perform following: Ø Using a BEA remote control, and with the door in the open position, unlock the Bodyguard, then press the Magic Wand key and then the number 2. This will force a setup for the open door position. If the green LED does not begin flashing, unplug the 7-position connector at the Bodyguard. Ø Use a multi-meter (set to a DC voltage scale) to test the voltage at terminal 6 & 7. Place the positive probe on terminal 7 and the negative probe on terminal 6. There should be approximately 12 Volts DC. If voltage is 0 volts, check the white and red/white striped wires from the connector back to the LO-21U for any breaks. Ø If wiring is good, check the voltage at the red and black wires on the LO-21U. Using a multi-meter, place the positive probe on the red wire, and the negative probe on the black wire. Voltage should not be less than 6 volts DC. If it is less, try increasing the stall voltage at the door control. If voltage is 0 volts, make sure there is a good connection on the red and black wires. Also make sure the LO- 21U has the proper input voltage at the orange and brown wires. 5. Once the Bodyguard is functioning correctly with regard to the open and closed door setup, walk testing may begin. q Do NOT proceed with walk-test until the Bodyguard is functioning correctly. 6. The LO-21U has two LED s to indicate what function it is performing. When the door is closed and someone steps into the detection zone of the Bodyguard, the illumination of the red LED on the LO-21U will indicate that the LO- 21U is triggering the safety circuit. Therefore, the door will remain closed until the Bodyguard zone is clear. The red LED will expire on the LO-21U and on the Bodyguard will shut off when the detection zone is clear. With the door in the closed position, stand in the Bodyguard detection field and have someone activate the door (Eagle, push plate, etc.). The door should not open. Clear the detection field of the Bodyguard, while keeping the door activated. The door should open thereafter. q If the red led comes on at the Bodyguard, but not at the LO-21U, check to insure good wiring on the gray and violet wires between the Bodyguard and the LO-21U. q If the red LED comes on at the Bodyguard and the LO-21U, but the door has no safety, check the green and yellow wires between the LO-21U and the door control. If connections are good, jumper the common and safety terminals at the door control, then activate the door to insure that the safety function is ok. 7. Once the Bodyguard zone is clear and the door has been activated, it will open and remain open as long as there is activation, or until door control and sensor hold-times have expired. If someone steps into the Bodyguard zone when the door is open, the illumination of the green LED will indicate that the LO-21U is triggering the activation circuitry of the door, thus holding the door open for as long as someone is in the Bodyguard detection pattern. q If the red led comes on at the Bodyguard, but not at the LO-21U, check to insure good wiring on the gray and violet wires between the Bodyguard and the LO-21U. q If the red LED comes on at the Bodyguard and the green LED comes on at the LO-21U, but the door does not hold open when the Bodyguard is in detection, check the blue and green wires between the LO- 21U and the door controls activation circuit. q Reverse the red and black wires at the LO-21U and try Step 7 again. q If all steps are Ok, LO-21U may be faulty. Replace as necessary. 75.1041.08 LO21U 20150708 Page 4 of 5

SET-UP INSTRUCTIONS Cont. 8. When all functions of the control and LO-21U have been confirmed, the lockout time delay will need to be set. Time delay is set by using dipswitches 1 through 5. Perform the following steps: q Activate the door to the open position. q Allow the door to close and count how many seconds it takes for the overall door closing cycle q Configure the dip switches according to the chart on Page 3 for the lock out time that is required q Activate the door again to the open position q Stand outside of the Bodyguard detection pattern, and while the door is closing, observe the red LED on the Bodyguard q The red LED on the Bodyguard should NOT illuminate during the closing cycle. If it does, it is probably seeing the door at the very last degree or two of door closing, which would indicate that the lock out time needs to be slightly increased. q Reconfigure the dipswitches to add 1 second of lock out time. q When the lock out time is correct. The red LED will not illuminate during the entire closing cycle of the door. q The last test is to insure that the Bodyguard detects an object as soon as the door has stopped closing. Simply allow the doors to begin closing, and step in behind the doors, into the Bodyguards field of detection (be sure to NOT break the path of the lockout safety beams, if so equipped). The red LED shall illuminate and remain on at the Bodyguard, and at the LO-21U, as soon as the door reaches the fully closed position, provided that an object remains in the Bodyguard s detection field. TROUBLE- SHOOTING PROBLEM PROBABLE CAUSE CORRECTIVE ACTION With the door closed, the RED LED does not come on upon Bodyguard detection. No Power applied to the Brown (+) and Orange (-) wires. Or The Gray and Violet wires are not properly connected to the Bodyguard pins 3,4. Step 1. Check for power 12-24 VAC / 15-24 VDC on the Brown (+) and Orange (-) wires with a meter. If voltage is there go to Step 2. Step 2. Jumper across Bodyguard connector pins 3,4. RED LED does not come on, go to Step 3. RED LED comes on, go to Step 4. **Step 3. Check continuity with a meter on the Orange, Brown, Violet and Gray wires from the back of the harness connector to the ends of the wire. Correct any problem connections. If no problem connections are found, replace LO21U. Step 4. Check Bodyguard Relay Mode function is set to 1. If OK replace Bodyguard. With the door closed, the GREEN LED comes on upon Bodyguard detection. With the door open, the GREEN LED does not come on upon Bodyguard detection. Dipswitch# 6 is in the wrong position. Reversed polarity or no motor voltage on the RED and BLACK wires. Step 1. Check that Dipswitch# 6 is set correctly for the application. Step 2. Remove harness from lockout and reinstall (this resets the LO21U). Step 3. Check motor voltage in door closed and open position. Call Technical support. Step 1. Check Dipswitch# 6 is correct for application. **Step 2. Check RED and BLACK wire connections at the motor or source of door open voltage. Correct any problem connections. Step 3. Reverse RED and BLACK LO21U wires at the motor. No LED display on the LO21U or Bodyguard and door will not open. Dipswitch# 7,8 are in the wrong position. Step 1. Check Dipswitches# 7,8 for proper position for application. Step 2. Check control box connections for the Yellow, Green and Blue wires. ** Remove power from sensors and door control before performing these checks.. Note: Lockout Relay will not function correctly when power close function is enabled on the door control. COMPANY CONTACT If after troubleshooting a problem, a satisfactory solution cannot be achieved, please call B.E.A., Inc. for further assistance during Eastern Standard Time at 1-800-523-2462 from 7am - 5pm. For after-hours, call East Coast: 1-866-836-1863 or 1-800-407-4545 / Mid-West: 1-888-308-8843 / West Coast: 1-888-419-2564 DO NOT leave any problem unresolved. If you must wait for the following workday to call B.E.A., leave the door inoperable until satisfactory repairs can be made. NEVER sacrifice the safe operation of the automatic door or gate for an incomplete solution. Web: www.beasensors.com 75.1041.08 LO21U 20150708 Page 5 of 5