Genesis Enclosure and Shaftway Model. Table of Contents

Similar documents
Creating An Accessible World. genesis. Enclosure or shaftway vertical platform lift for lifting heights up to 14 feet.

Creating An Accessible World. genesis SHAFTWAY. Shaftway vertical platform lift for lifting heights up to 14 feet.

Creating An Accessible World GENESIS DESIGN AND PLANNING GUIDE. For lifting heights up to 14 feet.

Creating An Accessible World. Vertical Platform Lift and Enclosure for lifting heights up to 14 feet.

Creating An Accessible World GENESIS SHAFTWAY PLANNING GUIDE. Shaftway vertical platform lift for lifting heights up to 14 feet.

GENESIS ENCLOSURE PLANNING GUIDE. Vertical Platform Lift and Factory Enclosure for lifting heights up to 14 feet.

GENESIS OPAL PLANNING GUIDE. Unenclosed Platform Lift for commercial applications of up to 5 feet lifting height. Creating An Accessible World

Table of Contents. Introduction What is an Inclined Platform Lift? Why an Inclined Platform Lift? Finishes How it Works...

Design Hot Line: or 1+(604)

Design Hot Line: or 1+(604)

X3-R. Garaventa X3-R. Residential Inclined Wheelchair Lift. Design and Planning Guide

Creating An Accessible World XPRESS II. Inclined platform lift for straight stairways.

Bruno VPL-3300B Series

National Reach. Local Service.

Bruno VPL-3300B Series

Table of Contents.

Creating An Accessible World. Inclined Platform Lift For Straight And Turning Stairways. Garaventa Wheelchair Lifts

Creating An Accessible World ELVORON CPL.

Garaventa Genesis OPAL

Elvoron Home Elevator

Home Elevator. Planning Guide

Design Guide ASME A18.1

ELVORON HR DESIGN AND PLANNING GUIDE

ELVORON HOME ELEVATOR

Elvoron CPL. Planning Guide

LIBRARY LIFT VERTICAL WHEELCHAIR LIFT SECTION GUELPH, ON. PAGE 1 PROJECT NO

Home Elevator. Specifically engineered for residential applications

OMEGA PLANNING GUIDE. Curved Inclined Platform Lift. Applicable Codes: ASME A17.1 ASME A18.1 CAN/CSA B355 CAN/CSA B m Part No.

ES-125 Inclined Platform Lift OWNER S MANUAL

Raising Standards in Accessibility

Built for every day, designed for any style.

Built for every day, designed for any style.

DRIVE: 1 hp motor; 1750 rpm, single phase, 120 VAC, 60 Hz, 13.4 Full Load Amps, 1.15 service factor, continuous duty

Raising Standards in Accessibility HIG H L A N D E R VERTIC A L P L A TFORM LIFTS

Built for every day, designed for any style.

V1504 Vertical Platform Lift OWNER S MANUAL

Infinity & Infinity HD

Quality Elevators by Garaventa ELVORON HR. Hydraulic Residential Elevator

Orion LU/LA Commercial Elevator OWNER S MANUAL

Bruno Vertical Platform Lift

DELTA PLANNING GUIDE. Straight Inclined Platform Lift. Applicable Codes: ASME A17.1 ASME A18.1 CAN/CSA B355 CAN/CSA B m Part No.

UNENCLOSED 90 /ADJACENT EXIT PLATFORM (NO PIT)

Discover the steps to MOBILITY

Infinity & Infinity HD

Planning Guide. ThyssenKrupp. ThyssenKrupp Access Residential Elevator Division. for Residential Elevators ASME A17.1, Part V, Section 5.

Residential Elevator OWNER S MANUAL (To Be Retained by Owner After Installation by Authorized Savaria Concord Dealer)

UNENCLOSED STRAIGHT-THRU PLATFORM (NO PIT)

Telecab Planning Guide

Residential Platform Lifts RPL400 / RPL600 Owner s Manual and Warranty Information

VPL REFERENCE GUIDE & OPTION LIST

SOLUTIONS AT EVERY LEVEL CURVED AND STRAIGHT STAIR LIFTS

Supra and Supra Linea Platform Lifts

Stairiser SR & CR. Inclined platform lifts.

VPL-SH1 Vertical Platform Lift

ALVARADO (1029 mm) 25 (635 mm) 36.5 (927.1 mm)

SOLUTIONS AT EVERY LEVEL CURVED AND STRAIGHT STAIR LIFTS

SB 200. > Flexible design. > Low space requirements. > High level of security. > Power-saving technologies. > smart digital control system

Elite RESIDENTIAL ELEVATOR. AmeriGlide Accessibility Solutions

Commercial accessibility WITHOUT COMPROMISE

Essential. Stairlift USERS MANUAL

HERCULES II DC OWNER S MANUAL HERCULES II DC RESIDENTIAL & COMMERCIAL

Executive 1m Steplift. The elegant solution for up to one metre of travel

Stairlift OWNER S MANUAL

Installation and Service Manual

AlumaView AV200. A. Section Metal Fabrications: Miscellaneous for steel supports.

Prolift SCL/Prolift HD

91 (2311 mm) (1581mm) (1375 mm)

Eclipse Gearless Residential Elevators OWNER S MANUAL

LCN 4310ME SERIES HINGE (PULL) SIDE MOUNTING. The 4310ME SENTRONIC is a. heavy duty, electrically controlled. closer/holder designed to provide

A LUXURY STANDARD CREATING A LIFETIME HOME

ROLLING COUNTER DOOR SYSTEMS

INCLINATOR ELEVETTE HOME ELEVATORS INDOOR & OUTDOOR VERTICAL PLATFORM LIFTS RESIDENTIAL & COMMERCIAL DUMBWAITERS

(1032 mm) 30.5 (775 mm) 44 ( mm)

Stairlift OWNER S MANUAL

lift design solution SCREW DRIVEN LOW SPEED LIFT FROM NTD LIFTS

TECTUS Concealed Hinges

Planning Guide. ThyssenKrupp. ThyssenKrupp Access. for Residential Elevators ASME A Section 5.3. March 28, 2006

savaria, Eclipse Residential Elevator OWNER'S MANUAL (To Be Retained by Owner After Installation by Authorized Savaria Dealer)

Owner s Manual and Warranty Information

SL-1000 Stairlift OWNER S MANUAL

Stannah Stairiser SR & Stairiser CR

/DOP BuyLine 1888 DORMA. Advanced Automatic Door Solutions. Automatics

ThyssenKrupp Access Manufacturing, LLC

VPL REFERENCE GUIDE & OPTION LIST

USER HANDBOOK. ALPHA Stairlift

LCN 4310ME SERIES FEATURES HINGE (PULL) SIDE MOUNTING. The 4310ME SENTRONIC is a. heavy duty, electrically controlled

EVERSERVE 610S/620S/625S SPRINGLESS ROLLING SERVICE DOORS LOW MAINTENANCE. EASE OF SERVICEABILITY. INDUSTRY LEADING COMMERCIAL & INDUSTRIAL SOLUTIONS

QUALITY AT EVERY LEVEL STRAIGHT STAIR LIFTS

SECTION METAL ATHLETIC SPORT LOCKERS

611/621/626 R APIDSLAT ADVANCED PERFORMANCE ROLLING STEEL SERVICE DOORS SPEED. HIGH CYCLES. SECURITY. DURABILITY.

Options for your Ascension Wheelchair Lifts

NON-SIZED SIZED HANDED

SL-1000 Stairlift OWNER S MANUAL

NON-SIZED SIZED HANDED

Stairfriend Stairlift Owner s Manual

Staying in their own homes as they age is important to nearly all adults 50 + *

B.07 Stairlift OWNER S MANUAL

English. Agile Lifting platform

Stannah Midilift SL/GL

NON-SIZED SIZED HANDED

Transcription:

Genesis Enclosure Model Table of Contents www.garaventa.ca Genesis Enclosure and Shaftway Model Table of Contents Table of Contents Introduction... 2 What is a Vertical Platform Lift?... 3 Why a Vertical Platform Lift?... 3 Design Assistance... 3 Custom Finishes... 3 How it Works... 4 Enclosure Model vs. Shaftway Model... 5 Platforms... 6 Platform Controls... 6 Call Stations... 7 Lifting Heights and Mast Sizes... 10 Leadscrew Drive System... 11 Hydraulic Drive System... 11 Special Features and Options... 12 Enclosure Base and Pit Dimensions... 18 Enclosure Platform Clearances... 19 Shaftway/Pit and Platform Clear Dimensions... 20 Garaventa Style Door and Gate Frames... 24 Fire Rated Door and Frames... 25 Garaventa Style Door Clearances... 26 Fire Rated Door Clearances... 30 Attachment Methods... 34 Lead Screw Drive System: Technical Reference of Standard Features... 36 Hydraulic Drive System: Technical Reference of Standard Features... 37 Enclosure Model Loading Diagram... 38 Shaftway Model Loading Diagram... 39-1 - Garaventa

Introduction Design Hot Line: 1-800-663-6556 or 1+604-594-0422 Garaventa - the world s #1 choice in accessibility solutions. Garaventa has been dedicated to developing safe and reliable accessibility solutions since 1978 and is now an industry leader worldwide. Years of hard work and an uncompromising commitment to quality have enabled us to perfect the internationally renowned Garaventa GSL Artira. This same commitment to quality has been applied to the Xpress II inclined platform lift and the Genesis vertical platform lift. The Xpress II is an inclined platform lift designed just for straight stairways. The sleek and attractive Xpress II can be installed indoors or outdoors and is a cost-effective access solution. The Genesis vertical platform lift incorporates state of the art features with elegant styling and quiet operation. The Genesis has a variety of models and configurations with many standard and optional features to choose from. With the development of the Genesis vertical platform lift, Garaventa has taken a significant step towards being able to solve most accessibility challenges for building owners. Our expertise in providing accessibility solutions has enabled our design team to take on the most challenging access situation, and develop innovative solutions for schools, places of worship, offices, hotels, airports, subways and a wide range of public and private buildings around the world. We have built our business on service. Please contact us and let us help solve your access challenges. Introduction 2003 Garaventa. As we are continuously improving our products, specifications outlined in this guide are subject to change without notice. - 2 - Garaventa

Genesis Enclosure Model Product Description www.garaventa.ca What is a Vertical Platform Lift? A vertical platform lift transports a passenger, in a wheelchair or someone who has difficulty using stairs, from one landing to another. Vertical platform lifts provide a code compliant access solution for lifting heights of up to 12 ft. (in some jurisdictions lifts can travel up to 14 ft.). A vertical platform lift can be operated independently or by an attendant. The Garaventa Genesis Vertical Platform Lift is versatile, attractive and suitable for indoor or outdoor applications. Why a Vertical Platform Lift? Cost-effective Vertical lifts are more cost-effective than an elevator and do not require a machine room to house the electrical and mechanical components. Blends with Environment A vertical lift can be an attractive alternative and take less space than a lengthy or winding ramp. Adjacent to stairs or in an area complementary to your building, these lifts can be blended or finished to compliment the aesthetics of the site. Meets ADA Requirements Garaventa vertical platform lifts are approved in the ADA Accessibility Guidelines as a means to provide public building access. Design Assistance With over 25 years of experience, Garaventa has the expertise to overcome almost any design challenge you face. Please call our Design Hot Line with your accessibility challenge. 1-800-663-6556 or 1+604-594-0422 Custom Finishes The standard finish is electrostatically applied baked powder finish in Satin Grey for the steel panels and champagne anodized aluminum extrusions for the framework. As an option, these components can be painted from the large selection of RAL colors (global paint color system). Alternatively, the Genesis enclosure can be supplied with 5mm (3/16") bronze tinted or clear plexiglass panels or 6mm (1/4 ) tempered glass panels. As an option Garaventa also offers Graphic Imaging and Exotic Finishes. Exotic finishes include brass and stainless effects created with special paint. Textured and speckled paint can be applied to the panels and extrusions. The panels can also be supplied with wood finishes, Formica, architectural metals or any material not exceeding 1/2 in thickness. Outdoor Applications When located outdoors, the Genesis is modified to ensure durability and reliable performance. Included in the outdoor package are: hot dippped galvanized base, plated platform, plated mezzanine brackets, sealed electrical box, rubber boots on switches and stainless steel fasteners. For outdoor installations in extreme climates, consult Garaventa for feasibility and specifications. In certain indoor applications, such as near a swimming pool, the outdoor package may be required. - 3 - Garaventa

How it Works Design Hot Line: 1-800-663-6556 or 1+604-594-0422 How it Works The Genesis vertical platform lift is offered in a variety of configurations and styles for different accessibility challenges. All versions of the Genesis Vertical Lift operate in the same manner and consists of a complete drive system, a platform with side walls, doors with an interlock system and call stations. The mast houses the electrical and mechanical components that raises and lowers the catalivered platform. The doors or gates can not be opened unless the platform is at the appropriate landing. The platform is called to the landing by using the call stations located at each landing. When a pssenger is on the lift, the platform controls override the call stations. Once at a landing, the door interlock is released and the door can be opened to exit. The Genesis can be used to provide access indoors or outdoors and can be installed directly on the floor or in a 76mm (3") deep pit. Upper Gate Mast Lower Door Platform Controls Grab Rail Platform Ramp (required for floor mount units only) Mounting Base Enclosure Model with Standard Straight-Through Configuration Shown - 4 - Garaventa

Genesis Enclosure Model System Overview www.garaventa.ca Enclosure Model vs. Shaftway Model The Genesis is available in two styles, the Enclosure Model and the Shaftway Model. The Enclosure Model consists of a mast, platform, doors and the walls that enclose the lift. The Shaftway Model consists of a mast, platform and doors. The walls enclosing the shaftway unit are built by others in accordance to Garaventa s specifications. Enclosure Model The enclosure frame is constructed of champagne color anodized aluminum extrusions. The attractive contoured corner posts feature vertical etched lines that enhance the appearance of the lift. Due to the unique design of the corner posts, nuts, bolts and screws are hidden, giving the lift an overall streamlined look. Horizontal cross members are fitted into the corner posts, securing the enclosure panels. The panels come in a choice of 16 gauge painted galvanized mild steel, 5mm (3/16 ) bronze tinted or clear Plexiglas or 6mm (1/4 ) tempered glass. Shaftway Model The Genesis Shaftway unit is designed to fit the essential lift components within your shaftway walls. The Genesis Shaftway Model can have either aluminum frame doors/gates, fire rated steel doors, or the doors can be supplied by others. All styles of doors/gates have interlocks integrated with our control system. Steel, Plexiglas or Tempered Glass Panels Anodized Aluminum Extrusion Corner Posts Shaftway Wall Supplied By Others Note: For visual effects, both doors are shown open; however due to safety reasons only one door can be open at a time. Anodized Aluminum Extrusion Cross Members Frame Mounted Call Station Doors Enclosure Model Shaftway Model - 5 - Garaventa

Platforms Design Hot Line: 1-800-663-6556 or 1+604-594-0422 Platforms The platform is rated for a load of 340 kg. (750 lbs.) and has 1070 mm (42 1/8") high side walls. The side wall in front of the mast includes a grab rail, platform controls and courtesy lights. The platform lighting remains on during travel and for a period of 8 seconds after the lift reaches the designated landing. This lighting is wired to a battery which provides emergency lighting power in the event of a mains power failure. Additional general ambient lighting will most likely be required to satisfy local code. Clear inside dimensions vary depending on the entry/exit configuration and size of platform. For sizes and clear dimensions of an Enclosure Model please see page 19 and for the Shaftway Model pages 20-23. Enclosure Platforms The Genesis Enclosure Model has 3 platform sizes to meet your requirements: 36 x 54 36 x 60 42 x 60 Shaftway Platforms The Genesis Shaftway Model has 5 platform sizes to meet your requirements: Compact (36 x 49 ) Standard (38 x 54 ) Mid-Size (38 x 60 ) Large (43 x 60 ) Custom Platform sizes listed are based on a Straight through configuration. Side Walls Grab Rail Platform Controls Platform Platform Controls The platform controls consist of two directional push buttons, a key switch, a safety indicator light, an emergency stop/alarm button and courtesy lights. The direction buttons are all constant pressure operation, as required by code. The platform is wired to support an ADA compliant phone (see page 13). Note: See page 17 for Three-Stop unit platform control information. Emergency Stop / Alarm Key Switch Safety Indicator Light Directional Controls Platform Light - 6 - Garaventa

Genesis Enclosure Model Call Stations www.garaventa.ca Call Stations The platform is called to the landing by pressing the appropriate directional button. The platform will automatically stop when it has reached that landing. Enclosure Frame Mounted Call Stations Call stations for the Genesis Enclosure can be mounted in the aluminum extrusion frame of the lift beside both the lower and upper door/gate. The call stations consist of up and down continuous pressure buttons, a key switch and an in use lamp. The lower call station also includes a service key switch. Call stations are available, as an option, for wall mounting, either flush mounted or surface mounted. Directly below the frame mount call station is the Door Interlock Emergency Access which is accessed by inserting a special tool into the hole and turning it 45. This will allow you to open the door for maintenance or an emergency (power failure covered by standard system). Note: See page 17 for Three-Stop unit intermediate call station information. Shaftway Frame Mounted Call Stations: Garaventa Style Doors Call stations for the Genesis Shaftway can be mounted in the aluminum extrusion frame beside the upper and lower door/gate. The call stations consist of up and down continuous pressure buttons, a key switch, and an in use lamp. The lower call station also includes a service key switch. Call stations are also available, as an option, for wall mounting, either flush mounted or surface mounted. Directly below the frame mounted call station is the Door Interlock Emergency Access which is accessed by inserting a special tool into the hole and turning it 45. This will allow you to open the door for maintenance or an emergency (power failure covered by standard system). Note: See page 17 for Three-Stop unit intermediate call station information. Note: Frame mounted call stations must not be used at landings with a ramp, or where a power door operator is installed. Up Button Call/Send Button Key Switch In Use Lamp Service Key Switch (Lower Call Station Only) Door Interlock Emergency Access Enclosure Frame Mounted Call Station for Garaventa Style Door Call / Send Buttons Key Switch In Use Lamp Service Key (Lower Call Station only) Door Interlock Emergency Access Shaftway Frame Mounted Call Station for Garaventa Style Door - 7 - Garaventa

Call Stations Design Hot Line: 1-800-663-6556 or 1+604-594-0422 Frame Mounted Call Station Dimensions 38 (1 1/2 ) 38 (1 1/2 ) 235 (9 1/4 ) 210 (8 1/4 ) Lower Landing Call Station Plate Dimensions Upper & Intermediate (optional) Landing Call Station Plate Dimensions Wall Mounted Call Station Dimensions Call stations for the Genesis can also be mounted on the wall. They can be surface mounted or recessed into the wall with a flush mount call station (includes collar for finishing wall). The call stations consist of up and down continuous pressure buttons, a key switch, and an in use lamp. 125 (4 7/8 ) 44 (1 3/4 ) 245 (9 5/8 ) 250 (9 7/8 ) 130 (5 1/8 ) 286 (11 1/4 ) 167 (6 1/2 ) Surface Wall Mounted Call Station Dimensions Flush Wall Mounted Call Station Collar Dimensions - 8 - Garaventa

Genesis Enclosure Model Call Stations www.garaventa.ca Optional Call Station Features Attendant Call Button In situations where the lift must be attendant operated, the call station can be modified and re-wired by your Garaventa representative to include an attendant call button. This optional call station configuration has only one directional control, which will always call the platform to your landing. Keyless Call Stations Keyless call stations are available as an option. A keyless lift does not have a keyswitch on the call stations or the platform. The directional buttons on the platform will override the directional buttons of the call stations. Shaftway Frame Mounted Call Stations: Fire Rated Doors When a fire rated door is used the call stations are usually mounted in the steel frame of the door, similar to the Garaventa style door call stations. Note: See page 17 for Three-Stop unit intermediate call station information. Call / Send Buttons In Use Lamp Key Switch Door Interlock Emergency Access Shaftway Frame Mounted Call Station for Fire Door - 9 - Garaventa

Drive System Design Hot Line: 1-800-663-6556 or 1+604-594-0422 Lifting Heights and Mast Sizes The mast size required for a particular site is determined by the vertical travel required between the upper and lower landings. When the site is measured, the lift height H is always defined as the distance from the surface at the lower landing (pit or floor) where the lift will sit to the upper landing floor as shown in the diagram below. If the lift is to be mounted directly on the surface of the lower landing and an entry ramp is used, then H equals the elevation change between the upper and lower landings. If the lift is pit mounted, then the measurement H is 76mm (3 ) greater than the elevation change between landings. This measurement is crucial for your custom designed lift. Be certain the height you provide is accurate. We recommend using the as built dimension. The width of the mast is 980mm (38 5/8 ) and is standard for all mast heights. Based on the measured value of H the drive mast is selected as follows; Max. H Value Enclosure Model Shaftway Model Mast Height 1118mm (44 ) GVL - EN - 41 GVL - SW - 41 1558mm (61 3/8 ) 1524mm (60 ) GVL - EN - 57 GVL - SW - 57 1965mm (77 3/8 ) 1905mm (75 ) GVL - EN - 72 GVL - SW - 72 2346mm (92 3/8 ) 2515mm (99 ) GVL - EN - 96 GVL - SW - 96 3035mm (119 1/2 ) 3124mm (123 ) GVL - EN - 120 GVL - SW - 120 3645mm (143 1/2 ) 3734mm (147 ) GVL - EN - 144 GVL - SW - 144 4255mm (167 1/2 ) 4343mm (171 )* GVL - EN - 168* GVL - SW - 168* 4920mm (193 3/4 )* * Hydraulic drive only. Upper Landing H H Lower Landing Pit Mount Floor Mount - 10 - Garaventa

Genesis Enclosure Model Drive System www.garaventa.ca Leadscrew Drive System Driven by a single-phase 3/4 H.P motor attached to a 1 ACME screw, the Genesis shaftway platform travels between landings at 2.7 meters (9 ft.) per minute. Mains Power Requirement: North America 208-240 VAC 60 Hz single phase on a dedicated 20 amp circuit. Hydraulic Drive System Driven by a 3 HP (2.2 KW), 24VDC hydraulic motor, the Genesis enclosure platform travels between landings at 5.2 meters (17 ft.) per minute. Mains Power Requirement: North America 120 VAC 60 Hz single phase on a dedicated 20 amp circuit. International 220-240 VAC 50 Hz single phase on a dedicated 20 amp circuit. Manual Lowering Tool Mast Top Cover Mast Top Cover Upper Landing Switch and Final Limit Switch 1 ACME Screw Travel Carriage Mast Side Rails Electric Control Box 3/4 HP Motor Upper Landing Switch and Final Limit Switch Travel Carriage Electric Control Box Hydraulic Cylinder Mast Side Rails 3.0 HP Motor (2.2 KW) Emergency Manual Lowering Valve Hydraulic Fluid Resevoir Battery Backup - 11 - Garaventa

Special Features and Options Design Hot Line: 1-800-663-6556 or 1+604-594-0422 Special Features and Options Electrical Disconnect A code compliant electrical disconnect is installed on the lift for both safety reasons and customer convenience. This disconnect shuts off the mains power and the 24V battery back-up system to the lift. For the Enclosure Model, the disconnect is located on the side of the mast closest to the lower landing door. For the Shaftway Model, the disconnect is located on the outside of the shaftway walls in a location determined by local code requirements. Manual Emergency Lowering Handwheel (Lead Screw Model Only) The manual emergency lowering handwheel has a black plastic handle and slotted shaft that engages the main drive screw. It should be stored in a safe place and is used to manually move the platform to the desired landing in case of a power outage. Battery Powered Emergency Lowering (Lead Screw Model Only - Optional) The Genesis can be supplied with an optional battery-powered emergency lowering system which is automatically activated in the event of a power failure. A secondary 24 VDC motor is connected to the main drive system of the lift and allows the passenger inside the lift to travel downwards only. The battery powered emergency lowering system moves the platform at a speed of approximately 0.3m/min. (1 ft/min.). The battery powered emergency lowering system is controlled by the same push buttons. The only difference in operation is that travel is only permitted in the down direction. ADA Compliant Telephone Some jurisdictions require that vertical platform lifts be equipped with an ADA compliant hands-free telephone. This speical phone is activated by the push of a button and automatically dials pre-programmed numbers to summon emergency assistance. It also provides audible and visible feedback to the passenger that assistance is on the way. The ADA telephone is integrated with the platform controls and is flush mounted. Note: This option will require the building owner to provide and maintain an active telephone line to the Genesis mast location. Manual Emergency Lowering Handwheel Emergency Lowering Control Systems - 12 - Garaventa

Genesis Enclosure Model Optional Features www.garaventa.ca Manual Emergency Lowering (Hydraulic Model Only - Standard) The manual emergency lowering device consists of a pull knob mounted in a box on the side of the mast. When this device is used, the platform is lowered to the desired landing. For the Enclosure Model the manual emergency lowering device is located on the side of the mast closest to the lower landing door. For the Shaftway Model the manual emergency lowering device is located on the outside of the shaftway in a location determined by local code requirements. Upon request, thumbscrews are available as replacement items for the screws that secure the lid to the emergency platform lowering box. Garaventa PDO - Power Door Operator The Garaventa Power Door Operator (PDO) automatically opens the door/gate when the platform arrives at a landing. When the lift is at the landing, the passenger can press the call station button or gently pull on the door/gate to activate the door opener. ADA compliant and obstruction sensitive, the door/gate mounted operator uses low voltage (24VDC) and has all wiring concealed within the lift. Certain applications may limit the use of this operator. Consult your authorized Garaventa representative for which power door operator is appropriate for your application. DMT Power Door Operator This ADA compliant option provides assistance for opening and closing the door/gate and is used for fire rated doors and other special applications. This wall mounted operator requires 110 VAC and is wired outside the lift. Consult your authorized Garaventa representative for which power door operator is appropraite for your application. Manual Emergency Lowering Mounted on Mast Rail Garaventa Power Door Operator Auxiliary Power System (Hydraulic Model Only - Standard) The Auxiliary Power System automatically activated in the event of a power failure. Two 12 VDC batteries allow the user inside the lift to travel up or down using the platform at a speed of approximately 5.2m/min (17ft/min). The number of trips varies with the state of the battery charge. DMT Power Door Operator Pit Switch For areas where local codes require a service pit switch, one can be mounted within arm s reach of the lower landing door. The pit switch locks out the lift while a serviceman is working under the platform. - 13 - Garaventa

Optional Features Design Hot Line: 1-800-663-6556 or 1+604-594-0422 Plexiglas Dome (Enclosure Model Only) For outdoor applications, a bronze tint Plexiglas dome can be mounted onto your enclosure. This dome comes standard with a drip rail for rain and condensation. Fan and Ventilation System (Enclosure Model with Dome Only) The fan and ventilation system consists of two exhaust fans, thermostatic control and a 12 VDC battery backup. The dual fans circulate and completely replace the air in the enclosure every minute when the inside enclosure temperature exceeds 85 F, in accordance with ASME A17.1 and A18.1 code requirements. Note: Some local codes require a fan and ventilation system for an enclosure lift fitted with Plexiglas panels and a dome. Plexiglas Dome Fan and Ventilation System Mast Dome, Fan and Ventilation System (also shown is the Remote Manual Emergency Lowering knob and access box, available with the Hydraulic Drive) Lower Landing Ramp A ramp is an alternative when a 76mm (3 ) deep pit cannot be provided. Six ramps are available for the Genesis, depending on the available space at landings. The ramps are available in slopes of 1:10 and 1:12. Both slopes are available in widths of 1069mm (42 ), 1225mm (48 1/4") or 1375mm (54 1/8"), depending on the door width. Enclosure Walls Entry/Exit Ramp Base 826mm (32 1/2 ) Lower Landing Entry Ramp (1:10 slope) 76mm (3 ) 974mm (38 3/8 ) Lower Landing Entry Ramp (1:12 slope) 76mm (3 ) - 14 - Garaventa

Genesis Enclosure Model Optional Features www.garaventa.ca Infill Panel Kits (Enclosure Model Only) Custom infill panel kits are available to seal off the dead space between the enclosure and the wall, next to the mast. The panel kit will enhance the overall appearance of the Genesis. The panel kit includes a frame and panels to fill the area. Infill Panel Infill Panel Infill Panel Kit Mast Side Wall Panel Kits (Shaftway Model Only) Custom mast side wall panel kits are available to fill the open area on either side of the mast. The panel kit will enhance the overall appearance of the Genesis and seal off this dead space. The panel kit includes the painted steel panels to fill the area between the mast and the inside of the shaftway wall. Mast Side Wall Panels Mast Mounting Base Optional Features Mast Side Wall Panel Kit - 15 - Garaventa

Optional Features Design Hot Line: 1-800-663-6556 or 1+604-594-0422 Bridges A custom bridge can be supplied for situations where a stairway must be crossed in order to use the lift. Please contact your Garaventa representative for pricing of these custom fabricated bridges and barrier options. Bridge Barrier Existing Stairs Bridges Mezzanine Tie-Back Brace A mezzanine tie-back brace is required to stabilize the Genesis for installations where there is no wall behind the mast to provide support. The mezzanine brace attaches the mast to a structural member at the upper landing level. Custom mezzanine brackets are available for various wall configurations. U-Shaped Tie Back Brace Y-Shaped Tie Back Brace U-Shaped Tie Back Brace Y-Shaped Tie Back Brace - 16 - Garaventa

Genesis Enclosure Model Optional Features www.garaventa.ca Three-Stop Lift The Genesis can be configured for three landings. The lower and middle landings must have a full-height 2032mm (6 8 ) door and the upper landing may have either a full-height door or a gate. Platform Call Button Key Switch In Use Lamp Frame Mounted Middle Call Station Call Stations on Three-Stop Lifts The middle landing call station consists of a call button and a key switch. This enables the lift to be called to the middle landing regardless of the platform s location. A plug is used to replace the upper button of the call station. The upper and lower call stations are the same as two-stop lifts. Surface and Flush Wall Mounted Middle Call Stations Platform Controls on Three-Stop Lifts A third button is added to the platform controls on Three-Stop lifts. Similar to an elevator, the lift continues past the middle landing when traveling from either the lower to upper or upper to lower landings. All other standard features are available with the controls as referenced on page 6 (Platform Controls section). Three-Stop Lift Platform Controls - 17 - Garaventa

Enclosure Base and Pit Dimensions Design Hot Line: 1-800-663-6556 or 1+604-594-0422 Enclosure Base and Pit Dimensions (For Leadscrew or Hydraulic Drive System) Platform Size Base Width Base Length Pit Width Pit Length 36 x 54 1420mm (55 7/8 ) 1508mm (59 3/8 ) 1445mm (56 7/8 ) 1533mm (60 3/8 ) 36 x 60 1420mm (55 7/8 ) 1660mm (65 3/8 ) 1445mm (56 7/8 ) 1685mm (66 3/8 ) 42 x 60 1572mm (61 7/8 ) 1660mm (65 3/8 ) 1597mm (62 7/8 ) 1685mm (66 3/8 ) Add 38mm (1 1/2 ) to pit width if the mast spreader bar is used. Pit Length Base Length Base Width Pit Width Mast 13mm (0.5 ) Typical Clearance Pit Depth 76 mm (3 ) Enclosure Base and Pit Dimensions - 18 - Garaventa

Genesis Enclosure Model Enclosure Platform Clearance Dimensions www.garaventa.ca Enclosure Platform Clearances Configuration Platform Size Platform Clear Width Platform Clear Length Net Usable Area Straight Through 36 x 54 915 mm (36") 1370 mm (53 7/8") 1.25 sq. m. (13.5 sq. ft.) (180º) Entry/Exit 36 x 60 915 mm (36") 1522 mm (59 7/8") 1.39 sq. m. (15.0 sq. ft.) 42 x 60 1068 mm (42") 1522 mm (59 7/8") 1.63 sq. m. (17.5 sq. ft.) 90º Entry/Exit 36 x 54 1002 mm (39 1/2") 1278 mm (50 3/8") 1.28 sq. m. (13.8 sq. ft.) 36 x 60 1002 mm (39 1/2") 1431 mm (56 3/8") 1.43 sq. m. (15.4 sq. ft.) 42 x 60 1155 mm (45 1/2") 1431 mm (56 3/8") 1.65 sq. m. (17.8 sq. ft.) 360º On/Off Same Side 36 x 54 915 mm (36") 1278 mm (50 3/8") 1.17 sq. m. (12.6 sq. ft.) (entry/exit 36 x 60 915 mm (36") 1431 mm (56 3/8") 1.31 sq. m. (14.1 sq. ft.) adjacent to mast) 42 x 60 1068 mm (42") 1431 mm (56 3/8") 1.53 sq. m. (16.4 sq. ft.) 360º On/Off Same Side 36 x 54 1002 mm (39 1/2") 1187 mm (46 3/4") 1.19 sq. m. (12.8 sq. ft.) (entry/exit 36 x 60 1002 mm (39 1/2") 1339 mm (52 3/4") 1.34 sq. m. (14.5 sq. ft.) opposite to mast) 42 x 60 1155 mm (45 1/2") 1339 mm (52 3/4") 1.55 sq. m. (16.6 sq. ft.) Entry/Exit Configurations The Genesis is available in various entry/exit configurations. The lift can be supplied as a straight through (180 ), a 90 (left or right exit) or an on/off same side (360 ) lift configuration. The standard configuration is straight through (180 ) with a 36 x 54 platform. Entry/ Exit Clear Width Clear Length Entry/ Exit Straight Through (180 ) Configuration Clear Length Clear Length Clear Width Entry/ Exit Clear Width Entry/ Exit Entry/Exit 90 Configuration (available with left or right enter/exit) On/Off Same Side (360 ) Configuration (must have a lift height of 2253mm (88 3/4 ) or greater) (available with enter/exit on either side) - 19 - Garaventa

Shaftway/Pit and Platform Clear Dimensions Shaftway Dimensions Design Hot Line: 1-800-663-6556 or 1+604-594-0422 Shaftway/Pit and Platform Clear Dimensions, Straight Through (180 ) Entry/Exit Platform Size Shaftway/Pit Width Shaftway/Pit Length Clear Width Clear Length Net Usable Area Compact 1368mm (53 7/8 ) 1295mm (51 ) 914mm (36 ) 1257mm (49 1/2 ) 1.15sq.m. (12.4 sq. ft.) Standard 1415mm (55 3/4 ) 1409mm (55 3/8 ) 962mm (37 7/8 ) 1370mm (53 7/8 ) 1.32sq.m. (14.2 sq. ft.) Mid-Size 1415mm (55 3/4 ) 1561mm (61 3/8 ) 962mm (37 7/8 ) 1522mm (59 7/8 ) 1.47sq.m. (15.8 sq. ft.) Large 1568mm (61 3/4 ) 1561mm (61 3/8 ) 1089mm (42 7/8 ) 1522mm (59 7/8 ) 1.66sq.m. (17.8 sq. ft.) Add 38mm (1 1/2 ) to pit width if a mast spreader is used. Shaftway / Pit Width 351mm (13 3/4 ) Clear Width Entry / Exit Mast 63mm (2 1/2 ) 76mm (3 ) Pit Depth 19mm (3/4 ) Clear Length Shaftway / Pit Length Entry / Exit 19mm (3/4 ) Straight Through (180 ) Entry/Exit Shaftway/Pit and Platform Clear Dimensions - 20 - Garaventa

Genesis Enclosure Model Shaftway Dimensions www.garaventa.ca Shaftway/Pit and Platform Clear Dimensions, 90 Entry/Exit Platform Size Shaftway/Pit Width Shaftway/Pit Length Clear Width Clear Length Net Usable Area Compact 1325mm (52 1/8 ) 1338mm (52 3/4 ) 955mm (37 5/8 ) 1216mm (47 7/8 ) 1.16sq.m. (12.5 sq. ft.) Standard 1372mm (54 ) 1451mm (57 1/8 ) 1002mm (39 1/2 ) 1329mm (52 3/8 ) 1.33sq.m. (14.3 sq. ft.) Mid-Size 1372mm (54 ) 1603mm (63 1/8 ) 1002mm (39 1/2 ) 1482mm (58 3/8 ) 1.49sq.m. (16.0 sq. ft.) Large 1525mm (60 ) 1603mm (63 1/8 ) 1129mm (44 1/2 ) 1482mm (58 3/8 ) 1.67sq.m. (18.0 sq. ft.) Add 38mm (1 1/2 ) to pit width if a mast spreader is used. Shaftway / Pit Width 351mm (13 3/4 ) Clear Width 19mm (3/4 ) Mast Entry / Exit 76mm (3 ) Pit Depth 63mm (2 1/2 ) Clear Length Shaftway / Pit Length Entry / Exit 19mm (3/4 ) 90 Entry/Exit Shaftway/Pit and Platform Clear Dimensions - 21 - Garaventa

Shaftway Dimensions Design Hot Line: 1-800-663-6556 or 1+604-594-0422 Shaftway/Pit and Platform Clear Dimensions, On/Off Same Side (360 ) Entry/Exit Adjacent to Mast Platform Size Shaftway/Pit Width Shaftway/Pit Length Clear Width Clear Length Net Usable Area Compact 1368mm (53 7/8 ) 1338mm (52 3/4") 914mm (36 ) 1216mm (47 7/8 ) 1.11sq.m. (12.0 sq. ft.) Standard 1415mm (55 3/4 ) 1451mm (57 1/8 ) 962mm (37 7/8 ) 1329mm (52 3/8 ) 1.28sq.m. (13.7 sq. ft.) Mid-Size 1415mm (55 3/4 ) 1603mm (63 1/8 ) 962mm (37 7/8 ) 1482mm (58 3/8 ) 1.42sq.m. (15.3 sq. ft.) Large 1568mm (61 3/4 ) 1603mm (63 1/8 ) 1114mm (43 7/8 ) 1482mm (58 3/8 ) 1.65sq.m. (17.8 sq. ft.) Add 38mm (1 1/2 ) to pit width if a mast spreader is used. Shaftway / Pit Width 351mm (13 3/4 ) Clear Width Mast 63mm (2 1/2 ) 76mm (3 ) Pit Depth 63mm (2 1/2 ) Clear Length Shaftway / Pit Length Entry / Exit 19mm (3/4 ) On/Off Same Side (360 ) Entry/Exit Adjacent to Mast Shaftway/Pit and Platform Dimensions - 22 - Garaventa

Genesis Enclosure Model Shaftway Dimensions www.garaventa.ca Shaftway/Pit and Platform Clear Dimensions, On/Off Same Side (360 ) Entry/Exit Opposite Mast Platform Size Shaftway/Pit Width Shaftway/Pit Length Clear Width Clear Length Net Usable Area Compact 1325mm (52 1/8 ) 1381mm (54 3/8 ) 955mm (37 5/8 ) 1176mm (46 1/4 ) 1.12sq.m. (12.1 sq. ft.) Standard 1372mm (54 ) 1494mm (58 7/8 ) 1002mm (39 1/2 ) 1288mm (50 3/4 ) 1.29sq.m. (13.9 sq. ft.) Mid-Size 1372mm (54 ) 1646mm (64 7/8 ) 1002mm (39 1/2 ) 1441mm (56 3/4 ) 1.44sq.m. (15.5 sq. ft.) Large 1525mm (60 ) 1646mm (64 7/8 ) 1155mm (45 1/2 ) 1441mm (56 3/4 ) 1.66sq.m. (17.9 sq. ft.) Add 38mm (1 1/2 ) to pit width if a mast spreader is used. Shaftway / Pit Width 351mm (13 3/4 ) Clear Width 19mm (3/4 ) Mast 63mm (2 1/2 ) Entry / Exit 76mm (3 ) Pit Depth 63mm (2 1/2 ) Clear Length Shaftway / Pit Length On / Off Same Side (360 ) Entry/Exit Opposite Mast Shaftway/Pit and Platform Dimensions - 23 - Garaventa

Doors and Interlocks Design Hot Line: 1-800-663-6556 or 1+604-594-0422 Garaventa Style Door and Gate Frames The Enclosure and Shaftway models utilize the Garaventa style door and gate. These doors and gates are prehung in an anodized aluminum champagne colored extrusion frame. The door and gate are constructed of matching aluminum extrusions with a powder coated 16 gauge galvanized steel kickplate and an upper panel (powder coated 16 gauge galvanized steel, bronze tinted or clear plexiglass or tempered glass). Custom finishes are also available as an option, please refer to page 3. This nonfire rated door and gate are an attractive alternative to the industrial looking fire rated door. The door height is 2032mm (6 8") and the gate height is 1070mm (42 1/8") and are both available in 3 widths: 905mm (35 5/8 ) 1046mm (41 1/8 ) 1198mm (47 1/8 ) See the Layouts and Clearances section on pages 26-29 for further door/gate and door/gate swing dimensions. Custom width doors and gates are also available. Interlock The Genesis interlock is a solenoid powered deadbolt with a monitoring circuit. The monitoring circuit verifies that the door is closed and that the deadbolt is engaged. Standard battery backup ensures locks still operate in the event of a power failure. If the deadbolt monitoring circuit is not complete, the lift can not be moved. The Garaventa interlock is CSA tested and approved. Door Interlock - 24 - Garaventa

Genesis Enclosure Model Doors and Interlocks www.garaventa.ca Fire Rated Door and Frames The fire rated door and frame is completely prehung and is constructed of 16 gauge steel. The rigid foam filled door has a vision panel and a delayed action door closer. The door has a 1 1/2 hour B label fire rating with an integrated interlock system. This door frame comes standard with a 2-button keyed call station. The fire rated door and frame is available in both 906mm (35 5/8 ) and 1059mm (41 5/8 ) clear door widths. See the Door Layouts and Clearances section on pages 30-33 for further door and door swing dimensions. This door is primarily used with Shaftway Model applications although can be used with the Enclosure Model when the enclosure is positioned adjacent to a fire-rated wall (consult Garaventa for further details). Interlock The fire rated door comes standard with a solenoid powered deadbolt with a monitoring circuit. The monitoring circuit verifies that the door is closed and that the deadbolt is engaged. Standard battery backup ensures locks still operate in the event of a power failure. If the deadbolt monitoring circuit is not complete, the lift can not be moved. - 25 - Garaventa

Garaventa Style Door Clearances Design Hot Line: 1-800-663-6556 or 1+604-594-0422 Garaventa Style Doors, Straight Through (180 ) Entry/Exit Door Door Width R/O* Width R/O* Height Door Swing Door Projection 36 905mm (35 5/8 ) 1070mm (42 1/8 ) 2120mm (83 1/2 ) 926mm (36 1/2 ) 982mm (38 5/8 ) 42 1046mm (41 1/8 ) 1211mm (47 5/8 ) 2120mm (83 1/2 ) 1067mm (42 ) 1123mm (44 1/4 ) 48 1198mm (47 1/8 ) 1363mm (53 5/8 ) 2120mm (83 1/2 ) 1219mm (48 ) 1275mm (50 1/8 ) Platform Size Platform C L Dimension Compact 808mm (31 7/8 ) Standard 832mm (32 3/4 ) Mid-Size 832mm (32 3/4 ) Large 921mm (36 1/4 ) Door Rough Opening Door Swing R/O* is Rough Opening Door Projection Mast 47mm (1 7/8 ) Jamb Depth (typ.) Platform C L Dim. 79mm (3 1/8 ) Side of Rough Opening to Hinge (typ.) Door Swing Door Rough Opening Door Projection - 26 - Garaventa

Genesis Enclosure Model Shaftway Door Dimensions www.garaventa.ca Garaventa Style Doors, 90 Entry/Exit Door Door Width R/O* Width R/O* Height Door Swing Door Projection 36 905mm (35 5/8 ) 1070mm (42 1/8 ) 2120mm (83 1/2 ) 926mm (36 1/2 ) 982mm (38 5/8 ) 42 1046mm (41 1/8 ) 1211mm (47 5/8 ) 2120mm (83 1/2 ) 1067mm (42 ) 1123mm (44 1/4 ) 48 1198mm (47 1/8 ) 1363mm (53 5/8 ) 2120mm (83 1/2 ) 1219mm (48 ) 1275mm (50 1/8 ) Platform Size Platform C L Dimension Compact 829mm (32 5/8 ) R/O* is Rough Opening Standard 852mm (33 1/2 ) Mid-Size 852mm (33 1/2 ) Large 941mm (37 ) Door Projection Mast 47mm (1 7/8 ) Jamb Depth (typ.) Platform C L Dim. Door Swing Door Rough Opening 79mm (3 1/8 ) Side of Rough Opening to Hinge (typ.) Door Swing Door Rough Opening Door Projection - 27 - Garaventa

Shaftway Door Dimensions Design Hot Line: 1-800-663-6556 or 1+604-594-0422 Garaventa Style Doors, On/Off Same Side (Entry/Exit Adjacent to Mast) Door Door Width R/O* Width R/O* Height Door Swing Door Projection 36 905mm (35 5/8 ) 1070mm (42 1/8 ) 2120mm (83 1/2 ) 926mm (36 1/2 ) 982mm (38 5/8 ) 42 1046mm (41 1/8 ) 1211mm (47 5/8 ) 2120mm (83 1/2 ) 1067mm (42 ) 1123mm (44 1/4 ) 48 1198mm (47 1/8 ) 1363mm (53 5/8 ) 2120mm (83 1/2 ) 1219mm (48 ) 1275mm (50 1/8 ) Platform Size Platform C L Dimension Compact 808mm (31 7/8 ) R/O* is Rough Opening Standard 832mm (32 3/4 ) Mid-Size 832mm (32 3/4 ) Large 908mm (35 3/4 ) Mast 47mm (1 7/8 ) Jamb Depth (typ.) Platform C L Dim. 79mm (3 1/8 ) Side of Rough Opening to Hinge (typ.) Door Swing Door Rough Opening DoorProjection - 28 - Garaventa

Genesis Enclosure Model Shaftway Door Dimensions www.garaventa.ca Garaventa Style Doors, On/Off Same Side (Entry/Exit Opposite to Mast) Door Door Width R/O* Width R/O* Height Door Swing Door Projection 36 905mm (35 5/8 ) 1070mm (42 1/8 ) 2120mm (83 1/2 ) 926mm (36 1/2 ) 982mm (38 5/8 ) 42 1046mm (41 1/8 ) 1211mm (47 5/8 ) 2120mm (83 1/2 ) 1067mm (42 ) 1123mm (44 1/4 ) 48 1198mm (47 1/8 ) 1363mm (53 5/8 ) 2120mm (83 1/2 ) 1219mm (48 ) 1275mm (50 1/8 ) R/O* is Rough Opening Mast 47mm (1 7/8 ) Jamb Depth (typ.) 79mm (3 1/8 ) Side of Rough Opening to Hinge (typ.) Door Swing Door Rough Opening Door Projection - 29 - Garaventa

Fire Rated Door Clearances Design Hot Line: 1-800-663-6556 or 1+604-594-0422 Fire Rated Doors, Straight Through Entry/Exit Door Door Width R/O* Width R/O* Height Door Swing Door Projection 36 908mm (35 3/4 ) 1131mm (44 1/2 ) 2102mm (82 3/4 ) 976mm (38 3/8 ) 1019mm (40 1/8 ) 42 1060mm (41 3/4 ) 1283mm (50 1/2 ) 2102mm (82 3/4 ) 1128mm (44 3/8 ) 1171mm (46 1/8 ) Platform Size Platform C L Dimension Compact 808mm (31 7/8 ) R/O* Rough Opening Standard 832mm (32 3/4 ) Mid-Size 832mm (32 3/4 ) Large 921mm (36 1/4 ) Door Rough Opening Door Swing Door Projection Mast 156mm (6 1/8 ) Jamb Depth (typ.) Platform C L Dim. 109mm (4 1/4 ) Side of Rough Opening to Hinge (typ.) Door Swing Door Rough Opening Door Projection - 30 - Garaventa

Genesis Enclosure Model Shaftway Door Dimensions www.garaventa.ca Fire Rated Doors, 90 Entry/Exit Door Door Width R/O* Width R/O* Height Door Swing Door Projection 36 908mm (35 3/4 ) 1131mm (44 1/2 ) 2102mm (82 3/4 ) 976mm (38 3/8 ) 1019mm (40 1/8 ) 42 1060mm (41 3/4 ) 1283mm (50 1/2 ) 2102mm (82 3/4 ) 1128mm (44 3/8 ) 1171mm (46 1/8 ) Platform Size Platform C L Dimension Compact 829mm (32 5/8 ) R/O* Rough Opening Standard 852mm (33 1/2 ) Mid-Size 852mm (33 1/2 ) Large 941mm (37 ) Door Projection Mast 156mm (6 1/8 ) Jamb Depth (typ.) Platform C L Dim. Door Swing Door Rough Opening 109mm (4 1/4 ) Side of Rough Opening to Hinge (typ.) Door Swing Door Rough Opening Door Projection - 31 - Garaventa

Shaftway Door Dimensions Design Hot Line: 1-800-663-6556 or 1+604-594-0422 Fire Rated Doors, On/Off Same Side (Entry/Exit Adjacent to Mast) Door Door Width R/O* Width R/O* Height Door Swing Door Projection 36 908mm (35 3/4 ) 1131mm (44 1/2 ) 2102mm (82 3/4 ) 976mm (38 3/8 ) 1019mm (40 1/8 ) 42 1060mm (41 3/4 ) 1283mm (50 1/2 ) 2102mm (82 3/4 ) 1128mm (44 3/8 ) 1171mm (46 1/8 ) Platform Size Platform C LDimension Compact 808mm (31 7/8 ) R/O* Rough Opening Standard 832mm (32 3/4 ) Mid-Size 832mm (32 3/4 ) Large 908mm (35 3/4 ) Mast 156mm (6 1/8 ) Jamb Depth (typ.) Platform C L Dim. 109mm (4 1/4 ) Side of Rough Opening to Hinge (typ.) Door Swing Door Rough Opening Door Projection - 32 - Garaventa

Genesis Enclosure Model Shaftway Door Dimensions www.garaventa.ca Fire Rated Doors, On/Off Same Side (Entry/Exit Opposite to Mast) Door Door Width R/O* Width R/O* Height Door Swing Door Projection 36 908mm (35 3/4 ) 1131mm (44 1/2 ) 2102mm (82 3/4 ) 976mm (38 3/8 ) 1019mm (40 1/8 ) 42 1060mm (41 3/4 ) 1283mm (50 1/2 ) 2102mm (82 3/4 ) 1128mm (44 3/8 ) 1171mm (46 1/8 ) R/O* Rough Opening Mast 156mm (6 1/8 ) Jamb Depth (typ.) 109mm (4 1/4 ) Side of Rough Opening to Hinge (typ.) Door Swing Door Rough Opening Door Projection - 33 - Garaventa

Attachment Methods Design Hot Line: 1-800-663-6556 or 1+604-594-0422 Enclosure Model Base and Mast Attachment Methods The base of the enclosure frame is fastened to the floor with lag screws. The floor or pit should be concrete and must be 3500 psi. reinforced, with a minimum 102 mm (4") thickness. If the floor is not concrete then it must be able to withstand the loads shown on page 38. After the base has been attached to the floor, the mast is bolted to the base. The mast of the lift is then attached to a wall using the mast tie back bracket and optional tie back rail kit (if required). It is mandatory for mast heights of 57, 72, 96, 120, 144 and 168 to be tied back to the wall. It is strongly recommended that all mast heights be tied back to the wall. Where no attachment wall exists, a mezzanine tie back brace is required (see page 16 for more details). Tie Back Bracket Tie Back Rail Kit (optional) Mast may be fastened directly to the wall Mast to Base Connection Enclosure Base Attachment Method - 34 - Garaventa

Genesis Enclosure Model Attachment Methods www.garaventa.ca Shaftway Model - Base and Mast Attachment Methods The base of the Genesis Shaftway Model is fastened to the floor with lag screws. The floor or pit should be concrete and must be 3500 psi. reinforced, with a minimum 102 mm (4") thickness. If the floor is not concrete then it must be able to withstand the loads shown on page 39. After the base has been attached to the floor, the mast is bolted to the base. The mast of the lift must be attached to a wall using a mast tie back bracket and if required the optional tie back rail kit. Tie Back Rail Kit (Optional) Mast may be fastened directly to the wall Tie Back Bracket Tie Back Bracket Mast to Base Connection Mounting Base Attachment Method - 35 - Garaventa

Technical Reference Design Hot Line: 1-800-663-6556 or 1+604-594-0422 Lead Screw Drive System: Technical Reference of Standard Features Platform Sizes: Standard Enclosure Platform: 914mm (36 ) x 1370mm (54 ) Optional Enclosure Platform: 914mm (36 ) x 1522mm (60 ) 1068mm (42 ) x 1522mm (60 ) Standard Shaftway Platform: 962mm (38 ) x 1370mm (54 ) Optional Shaftway Platform: 914mm (36 ) x 1257mm (49 ) 962mm (38 ) x 1522mm (60 ) 1089mm (43 ) x 1522mm (60 ) Rated Load: 340 kg (750 lbs), with a safety factor of 5 Speed: 2.7 meters (9 ft) per minute at full load Sample Data Label for Lead Screw Drive Unit Operating Controls: Keyed Controls: Keyswitch on call stations and platform controls Directional Controls: Continuous pressure switches Control Voltage: 24 VDC Drive System: Motor: Lifting heights of 1829mm (72 ) and under utilize a 3/4hp single phase AC Motor, 208-240V, 50/60Hz, 8 Amps Lifting heights of 2438mm (96 ) and over utilize a 1hp single phase AC Motor, 208-240V, 50/60Hz, 9 Amps Drive Type: ACME screw (1 diameter) Power Supply: 208 to 240 VAC single phase 60 Hz Safety Features: Safety Nut: Safety nut automatically engages if drive nut fails. Platform falls less than 13mm (1/2 ) when safety nut engages. Engaging safety nut trips the safety circuit. Door Interlocks: Solenoid powered deadbolt with monitoring circuit. Deadbolt fails in the locked position in the event of power failure. Battery backup provided. Emergency Stop: Stops platform travel and sounds audible alarm. Emergency Operation: Equipped with a manual lowering wrench. Optional battery powered lowering system available. Finish: Enclosure Frame and Drive Mast: Anodized aluminum Platform Sidewalls and Drive Mast Cover: Electrostatically applied baked powder finish on 16 gauge galvanized steel panels RAL color #7030 (Stone Grey). Enclosure Sidewalls and Doors: Standard electrostatically applied baked powder finish on 16 gauge galvanized steel panels RAL color #7030 (Stone Grey) or optional 3/16 thick Plexiglas (Grey tint). Optional Finishes: Extrusions and panels can be painted any color in the RAL chart. Graphic Imaging or Exotic Paint Finishes can be applied to the enclosure panels. - 36 - Garaventa

Genesis Enclosure Model Technical Reference www.garaventa.ca Hydraulic Drive System: Technical Reference of Standard Features Platform Sizes: Standard Enclosure Platform: 914mm (36 ) x 1370mm (54 ) Optional Enclosure Platform: 914mm (36 ) x 1522mm (60 ) 1068mm (42 ) x 1522mm (60 ) Standard Shaftway Platform: 962mm (38 ) x 1370mm (54 ) Optional Shaftway Platform: 914mm (36 ) x 1257mm (49.5 ) 962mm (38 ) x 1522mm (60 ) 1089mm (43 ) x 1522mm (60 ) Rated Load: 340 kg (750 lbs), with a safety factor of 5 Sample Data Label for Hydraulic Drive Unit Speed: 5.2 meters (17 ft) per minute at full load Operating Controls: Keyed Controls: Keyswitch on call station and platform controls Directional Controls: Continuous pressure switches Control Voltage: 24 VDC Drive System: Motor: 2.2 KW (3 HP) Motor: 120 VAC single phase, 60 Hz. @ 15 Amps (Some international locations 220-240 VAC, 50/60 Hz., 8 Amps). Drive Type: Chained Hydraulic (Dual 5/8 ANSI 50 chains) Power Supply: 120VAC single phase, 50/60 Hz @ 12 Amp standard for North America. 208 to 240 VAC single phase 50/60 Hz @ 6 Amps optional where required. Safety Features: Safety: Monitored slack chain device. Automatically engages if the drive chain fails. The platform falls less than 13mm (1/2 ) when the slack chain safety device engages. Door Interlocks: Solenoid powered deadbolt with monitoring circuit. Deadbolt fails in the locked position in the event of power failure. Battery backup provided. Emergency Stop: Stops platform travel and sounds audible alarm. Emergency Operation: Equipped with auxiliary power system that operates lift in up and down direction. Also equipped with manual lowering valve. Finish: Enclosure Frame and Drive Mast: Anodized aluminum Platform Sidewalls and Drive Mast Cover: Electrostatically applied baked powder finish on 16 gauge galvanized steel panels RAL color #7030 (Stone Grey). Enclosure Sidewalls and Doors: Standard electrostatically applied baked powder finish on 16 gauge galvanized steel panels RAL color #7030 (Stone Grey) or optional 3/16 thick Plexiglas (Grey tint). Optional Finished: Extrusions and panels can be painted any color in the RAL chart. Graphic Imaging or Exotic Paint Finishes can be applied to the enclosure panels. - 37 - Garaventa

Enclosure Model Loading Diagram Design Hot Line: 1-800-663-6556 or 1+604-594-0422 Enclosure Model Loading Diagram - Wall and Floor Reactions F2 (Mast Weight) F5 L1 F6 (Enclosure Weight) Tieback Height F1 (1000 lbs.) 76.2mm (3.0 ) Size L1 L2 36 x 54 683mm (26.9 ) 1171mm (46.11 ) 36 x 60 683mm (26.9 ) 1171mm (46.11 ) 42 x 60 759mm (29.9 ) 1324mm (52.11 ) F3 L2 152.3mm (5.99 ) F4 139.88mm (5.51 ) Mast Enclosure Mast Height Tieback Height F2 F3 F4 F5 F6 Model Weight lbs lbs lbs lbs lbs 41 400 1558mm (61.3 ) 1456mm(57.3 ) 175 1251 486 782 400 57 450 1965mm (77.4 ) 1863mm(73.3 ) 215 1308 536 612 450 72 500 2346mm (92.4 ) 2244mm(88.3 ) 260 1370 585 509 500 96 625 3035mm (119.5 ) 2933mm(115.5 ) 375 1527 710 386 625 120 700 3645mm (143.5 ) 3543mm(139.5 ) 450 1627 758 321 700 144 800 4255mm (167.5 ) 4153mm(163.5 ) 525 1736 884 275 800 168 900 4920mm (193.7 ) 4818mm (189.7 ) 600 1846 981 237 900 Reactions are based on a 144 mast and a 42 x 60 platform. These are reaction forces generated by the lift. Adhere to building code, regulations and safety factors for supporting structures. Consult a Structural Engineer or Architect in your jurisdiction. Wind loading effects are not considered in these calculations. - 38 - Garaventa

Genesis Enclosure Model Shaftway Model Loading Diagram www.garaventa.ca Shaftway Model Loading Diagram - Wall and Floor Reactions F2 (Mast Weight) L1 F5 Tieback Height 76.2mm (3.0 ) F1 (1000 lbs.) Size L1 L2 Compact 683mm (26.9 ) 1060mm (41.7 ) Standard 683mm (26.9 ) 1060mm (41.7 ) Mid-Size 683mm (26.9 ) 1060mm (41.7 ) Large 759mm (29.9 ) 1060mm (41.7 ) F3 F4 L2 152.3mm (5.99 ) Mast Mast Height Tieback Height F2 F3 F4 F5 Model lbs lbs lbs lbs 41 1558mm (61.3 ) 1456mm(57.3 ) 175 1251 486 782 57 1965mm (77.4 ) 1863mm(73.3 ) 215 1308 536 612 72 2346mm (92.4 ) 2244mm(88.3 ) 260 1370 585 509 96 3035mm (119.5 ) 2933mm(115.5 ) 375 1527 710 386 120 3645mm (143.5 ) 3543mm(139.5 ) 450 1627 758 321 144 4255mm (167.5 ) 4153mm(163.5 ) 525 1736 884 275 168 4920mm (193.7 ) 4818mm (189.7 ) 600 1846 981 237 Reactions are based on a 144 mast and a 42 x 60 platform. These are reaction forces generated by the lift. Adhere to building code, regulations and safety factors for supporting structures. Consult a Structural Engineer or Architect in your jurisdiction. Wind loading effects are not considered in these calculations. - 39 - Garaventa

Design Hot Line: 1-800-663-6556 or 1+604-594-0422 Garaventa Vertical Lift Vertical Wheelchair Platform Lift Specification Template Model: Genesis Enclosure and Shaftway Need Assistance Writing the Specification? GSL Artira specifications will vary from one building site to another based on the stairway configuration, building materials, user requirements and local codes. Your Local Authorized Garaventa Dealer has the expertise to assist and develop an appropriate design specification for your accessibility project. Authorized Garaventa Dealers can be found Worldwide, call or email Garaventa for the Dealership nearest you. In addition, professional designers at Garaventa Accessibility are available to answer your technical questions and to assist you with the design and specs. Garaventa Accessibility Phone: (604) 594-0422 Fax: (604) 594-9915 Toll Free: 1-800-663-6556 web Site: www.garaventa.ca Email: productinfo@garaventa.ca Other Garaventa Accessibility products include: Stair-Lift GSL Artira - Inclined Platform Lift for straight and turning stairways Stair-Lift Xpress II - Inclined Platform Lift for straight stairways Genesis OPAL - Vertical Platform Lift for lifting heights up to 1448mm (57 ) - 40 - Garaventa