PRESSURE REDUCING VALVE

Similar documents
Mustang Series PRESSURE REDUCING CONTROL VALVE. M115 (Globe) M1115 (Angle) Schematic. Standard Components. Options & Accessories.

PRESSURE REDUCING VALVE

PRESSURE REDUCING VALVE

PRESSURE REDUCING CONTROL VALVE

LEAD FREE * LFM115 (Globe) LFM1115 (Angle)

LEAD FREE * LFF115 (Globe) LFF1115 (Angle)

FLOOD PROTECTION SHUT DOWN VALVE (3 and smaller)

LEAD FREE * LFF113RFP Flood Protection Shut Down Valve

LEAD FREE * LFF113RFP Wireless Smart Flood Protection Shut Down Valve with SentryPlus Alert Technology

LEAD FREE * LFF113FP. Wireless Smart Flood Protection Shut Down Valve with SentryPlus Alert Technology. Materials NOTICE NOTICE ES--LFF113FP

Mark 6127 Series. Pressure Regulators Mark 6127 Series. Pressure Reducing Valves. Valve Features. Operation

Mark 5108 Series. Back Pressure Regulating Valves Mark 5108 Series. Back Pressure Regulating Valves. Valve Features. Operation

PRESSURE RELIEF VALVE CONTROL VALVE

PRESSURE REDUCING CONTROL VALVES

PRESSURE RELIEF / SUSTAINING CONTROL VALVES

PRESSURE RELIEF / SURGE ANTICIPATOR CONTROL VALVE

ALTITUDE CONTROL VALVES FOR ONE WAY FLOW

COMBINATION PRESSURE REDUCING AND SOLENOID SHUTOFF CONTROL VALVES 2.01 COMBINATION RESSURE REDUCING AND SOLENOID SHUTOFF CONTROL VALVE

Deep Well Pump Control Valve

BERMAD Waterworks. Pressure Relief/Sustaining Valve. Model: WW Series. Features and Benefits. Major Additional Features

DOROT CONTROL VALVES CATALOGUE

MODEL 106/206-PG POWER OPERATED GLOBE VALVE Sizes 1/2" to 8" (106-PG) 3" to 10" (206-PG) Installation, Operating and Maintenance Instructions

BERMAD Waterworks. Booster Pump Control Valve Active Check Valve. 700 Series. Model 740. Features and Benefits. Major Additional Features

SOLENOID CONTROL VALVE

MODULATING FLOAT CONTROL VALVE

FLOAT CONTROL VALVES

NYLON & PVC VALVES MINING DIVISION PRESSURE REDUCING VALVES ENSURE DOWNSTREAM PRESSURE PVC NYLON

Electronic Control Valves

HYDRAULIC CONTROL VALVES

BERMAD Waterworks. Electronic Control Valve. 700 Series. Model Features and Benefits. Major Additional Features

BERMAD Fire Protection

50-01 (Full Internal Port) (Reduced Internal Port) Pressure Relief. & Pressure Sustaining Valve MODEL

BERMAD BERMAD BERMAD WW M

Booster Pump Control Valve

D-023 PN 16 / 25. Combination Air Valve for Wastewater PATENTED. Description. Applications. Operation. Main Features

SECTION ELECTRONIC ACTUATED PRESSURE REDUCING VALVES AND ACCESSORIES

Installation, Operation, and Maintenance Manual Series LFF113FP Wireless Smart Universal Flood Protection ACV System with SentryPlus Alert Technology

T he -A900 series of automatic control

Check Valve MODEL. Schematic Diagram. Product Dimensions Data:

BERMAD Irrigation. IR-300 Basic Valve. 300 Series. ??????? Basic Valve

BERMAD Waterworks. BERMAD 700 Large Size Series. 700 Series. Features and Options. Model: 700-M5, 700-M6, 700-M5L

700 LARGE SIZE SERIES

CAST IRON VALVES PRESSURE REDUCING VALVES SERIES

DWS 41. Installation Data 44 Performance Specs DWS & DW-PRV Series

SECTION GENERAL-DUTY VALVES FOR PLUMBING PIPING

SECTION VALVES PART 1 -GENERAL

Flow Control Valve IOM 770-U

T e n c a n Backflo w Specialties

BERMAD Waterworks. 800 Series. Technical Specifications Metric

MODEL 106-PT / 106-PTC / S106-PT / S106-PTC DOUBLE CHAMBER HYDRAULICALLY OPERATED VALVE

D-040 PN 16 D-040-C PN 16. Combination Air Valve. Description. Applications. Operation. Main Features

UPDATE LOG FOR TECHNICAL PROVISIONS DIVISION 4 Date Item(s) Changed Page # 10/1/13 TECHNICAL PROVISIONS DIVISION 4 VALVE SPECIFICATIONS

D-040 PN 16 D-040-C PN 16. Combination Air Valve. Description. Applications. Operation. Main Features

Series 957, 957N, 957Z, 957RPDA, 957NRPDA, 957ZRPDA

Automatic Control Valves

P99 Pressure Reducing Regulator

PACIFIC. for Agricultural Irrigation Applications. exceptional quality unparalleled performance

Backflow Irrigation Control Station BIC-1000

Booster Pump Control Valve

Distributed By: M&M Control Service, Inc KO/650-01KO

D-26. Combination Air Valve for Wastewater. Description. Applications. Operation. Main Features

TECHNICAL VALVES PRINCIPLE OF OPERATION DOROT PLASTIC VALVES. 3-Way Control System. 2-Way Control System T48

Colt Series C400, C500

OPERATION MANUAL. DUCTILE Models NT100 NOMAD TRANS-FLO AIR-OPERATED DOUBLE DIAPHRAGM PUMPS. A JDA Global Company. 5/13 rev.2

The TD Series Tilting Disc Check Valve Sizes from 2 to 72 #125 and #250 ratings available 55 seating angle 40% size increase through seat.

Typical Applications. Installation

BERMAD Irrigation. 300 Series. Basic Valve. ??????? IR-300 Basic Valve.

Differential Piston Control Valves Pressure, Level and Flow Control

Series Roll Seal

Three Way Pilot Control

PROJECT TITLE PROJECT NO: CONTRACT TITLE GRANT NO: UNIVERSITY OF CALIFORNIA, DAVIS CITY, CALIFORNIA

SECTION GENERAL-DUTY VALVES FOR HVAC PIPING. A. Contents of Division 23, HVAC and Division 01, General Requirements apply to this Section.

HYDRAULIC CONTROL VALVES

AUTOMATIC FLOW CONTROL VALVE. INSTRUCTIONS Installation - Operation - Inspection - Maintenance

SECTION Pressure & Temperature Control

DARTMOUTH COLLEGE DESIGN January 3, 2012 & CONSTRUCTION GUIDELINES

Pressure Reducing Valve with Low Flow By-Pass MODEL. Schematic Diagram. Optional Features. Typical Applications

Float Valve MODEL. Schematic Diagram. Optional Features. Typical Applications

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL

Installation, Operation and Maintenance Instructions

AWWA Swing Check Valves

See Water Pressure Reducing Valves Catalog (PHBRWPRV) for more detailed information about the products in this section.

SWING CHECK VALVES SERIES 52-SC SERIES 600

MODEL 5540 CONTENTS. Installation, Operation and Maintenance Instructions 1.0 GENERAL

T he -A900 series of automatic control valves

See Water Pressure Reducing Valves Catalog (PHBRWPRV) for more detailed information about the products in this section.

VB VALVES & AUTOMATION

Brown University Revised August 3, 2012 Facilities Design & Construction Standards SECTION HVAC&R VALVES

INSTRUCTION MANUAL INSTALLATION OPERATION TROUBLESHOOTING MAINTENANCE PRESSURE RELIEF VALVE WITH SURGE ANTICIPATION (HYDRAULIC) FEATURE MODEL 50RWR-A

Automatic Control Valves. Providing quality, performance, dependability, and value for water control applications

AIRPRO MAX AIR VALVES. Engineering Creative Solutions for Fluid Systems Since 1901

INSTALLATION / OPERATION / MAINTENANCE MODEL SERVICE AND MAINTENANCE OF 600 SERIES VALVES UNDERSTANDING THE 600 SERIES VALVES

Ideal Installation. I & M Mark 67 (1/2 6 ) Control Line. Installation & Maintenance Instructions for Mark 67 Pressure Regulators

A. American National Standards Institute: 1. ANSI Z Relief Valves for Hot Water Supply Systems.

Type 644 and 645 Differential Pressure Pump Governors

Piston Actuated Valve Type G

CCNE Check Valves Engineering Creative Solutions for Fluid Systems Since 1901

Bourdon Tube Pressure Gauge

AUTOMATIC CONTROL VALVES. TIS asia

Kunkle Models 91/218/228 liquid relief valves Safety and relief products

Transcription:

Schematic Throttles to reduce high upstream pressure to constant lower downstream pressure Closes quickly when downstream pressure exceeds reduced pressure setpoint 3 PRESSURE REDUCING VALVE with SURGE CONTROL FEATURE 06/08 Ideal for use when high capacity on-off equipment is installed downstream Reducing and Surge Control setpoints are separately adjustable P/L 2 Standard Components 1 Main Valve (Single Chamber) 2 Pressure Reducing Control 3 Downstream Surge Control 4 Fixed Orifice (AOS) 4 X Y/FC X X 1 FLOW CLOSES VALVE X Options & Accessories X Isolation Cocks (2) FC Flo-Clean Strainer (1) Y Y-Strainer (Replaces Flo-Clean) ACS Adjustable Closing Speed (3) (Replaces Fixed Orifice) AOS Adjustable Opening Speed (1) P Position Indicator (3) L Limit Switch (3) (1) Standard 3 & Smaller (2) Standard 4 & Larger (3) Optional All Sizes (2) OPENS VALVE Operations The Watts ACV Combination Pressure Reducing and Surge Control Valve is designed to automatically reduce a fluctuating higher upstream pressure to a constant lower downstream pressure, and will quickly modulate toward a closed position if downstream pressure suddenly becomes greater than the desired regulated setpoint. The quick closing action prevents possible damaging high inlet pressure from passing through the valve to downstream piping. Normal regulating action is controlled by a normally open, pressure reducing pilot designed to: 1) Open (allowing fluid out of the main valve cover chamber) when downstream pressure is below the adjustable setpoint, and 2) Close (allowing fluid to fill the main valve cover chamber) when downstream pressure is above the adjustable setpoint. A decrease in downstream pressure causes the valve to modulate toward an open position, raising downstream pressure. An increase in downstream pressure causes the valve to modulate toward a closed position, lowering downstream pressure. If downstream pressure suddenly becomes greater than the desired regulated setpoint, the normally closed surge control pilot opens and rapidly admits higher inlet pressure into the valve cover, increasing rate of valve closure. Normal pressure reducing operation resumes when downstream pressure decreases below the desired regulated setpoint.

Materials Globe Angle Body & Cover: Ductile Iron ASTM A536 Coating: NSF Listed Fusion Bonded Epoxy Lined and Coated D K L K Trim: 316 Stainless Steel K Elastomers: Stem, Nut & Spring: Buna-N (standard) EPDM Viton Stainless Steel A B C E F G H I J Operating Pressure Operating Temperature Pilot System Tubing & Fittings Threaded = 400 psi Buna-N: 160 F Maximum Reducing Control Copper / Brass (Standard) 150 Flanged = 250 psi EPDM: 300 F Maximum 30-300 psi (Standard) Stainless Steel (Optional) 300 Flanged = 400 psi Viton: 250 F Maximum 0-30 psi (Optional) Surge Control 20-200 psi (Standard) 0-30 psi (Optional) Dimensions VALVE SIZE A B C D E F G H I J K L GLOBE THRD. GLOBE 150# GLOBE 300# COVER TO CENTER THRD. 150# 300# THRD. 150# 300# PORT SIZE PORT SIZE SHIPPING WEIGHTS* 1-1/4 7-1/4 - - 5-1/2 3-1/4 - - 1-7/8 - - 3/8 1/4 20 1-1/2 7-1/4 8-1/2 9 5-1/2 3-1/4 4 4-1/4 1-7/8 4 4-1/4 3/8 1/4 25 2 9-3/8 9-3/8 10 6-1/2 4-3/4 4-3/4 5 3-1/4 3-1/4 3-1/2 3/8 1/2 40 2-1/2 11 11 11-5/8 7-1/2 5-1/2 5-1/2 5-7/8 4 4 4-5/16 1/2 1/2 65 3 12-1/2 12 13-1/4 8-1/4 6-1/4 6 6-3/8 4-1/2 4 4-3/8 1/2 1/2 95 4-15 15-5/8 10-5/8-7-1/2 7-7/8-5 5-5/16 3/4 3/4 190 6-20 21 13-3/8-10 10-1/2-6 6-1/2 3/4 3/4 320 8-25-3/8 26-3/8 16-12-3/4 13-1/4-8 8-1/2 1 1 650 10-29-3/4 31-1/8 17-1/8-14-7/8 15-9/16-8-5/8 9-5/16 1 1 940 For larger sizes consult factory Valve Cover Chamber Capacity Valve Size (in) 1-1/4 1-1/2 2 2-1/2 3 4 6 8 10 fl.oz. 4 4 4 10 10 22 70 - - U.S. Gal - - - - - - - 1-1/4 2-1/2 Valve Travel Valve Size (in) 1-1/4 1-1/2 2 2-1/2 3 4 6 8 10 Travel (in) 3/8 3/8 1/2 5/8 3/4 1 1-1/2 2 2-1/2

Sizing Size (in) 1-1/4 1-1/2 2 2-1/2 3 4 6 8 10 Maximum Continuous (GPM) 95 130 210 300 485 800 1850 3100 5000 Maximum Intermittent (GPM) 119 161 265 390 590 1000 2300 4000 6250 Minimum Continuous (GPM) 1 1 1 20 30 50 115 200 300 Maximum continuous flow based on velocity of 20 ft. per second. Maximum intermittent flow based on velocity of 25 ft. per second. Minimum continuous flow based on velocity of 1 ft. per second. NOTE: The above chart is a suggested guide. Inlet pressure, outlet pressure, minumum, normal and maximum flow rates should be considered for specific valve sizing. Contact Watts ACV for details. Cavitation Chart After selecting the valve size, locate inlet and outlet pressures on this chart. If the intersection point falls in the shaded area, cavitation can occur. Operation of valves continually in the cavitation zone should be avoided. Consult Watts ACV for alternatives. INLET PRESSURE - PSI 300 CAVITATION ZONE 280 260 240 220 200 180 160 140 120 100 80 60 40 20 0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 OUTLET PRESSURE - PSI

Cross-Sectional Detail Main Valve 1 2 3 4 5 6 7 10 11 12 13 14 15 16 8 9 17 ITEM DESCRIPTION MATERIAL 1 Cover ASTM A536 65-45-12 Epoxy Coated Ductile Iron 2 Cover Bearing ASTM A276 304 Stainless Steel 3 Shaft / Stem ASTM A276 304 Stainless Steel 4 Stud ASTM A570 Gr.33 Zinc Plated Steel 5 Cover Nut ASTM A570 Gr.33 Zinc Plated Steel 6 Diaphragm* Buna-N (Nitrile) 7 Body ASTM A536 65-45-12 Epoxy Coated Ductile Iron 8 Seat Disc* Buna-N (Nitrile) 9 Seat Ring ASTM A743 CF8M (316) Stainless Steel 10 Spring ASTM A276 302 Stainless Steel 11 Stem Nut ASTM A276 304 Stainless Steel 12 Spring Washer ASTM A276 304 Stainless Steel 13 Diaphragm Washer ASTM A536 65-45-12 Epoxy Coated Ductile Iron 14 Disc Retainer ASTM A536 65-45-12 Epoxy Coated Ductile Iron 15 Spacer Washer* Fiber* 16 Disc Guide ASTM A743 CF8M (316) Stainless Steel 17 Seat Gasket* Buna-N (Nitrile) * Contained in Main Valve Repair Kit

Controls and Accessories Model CP-15 Pressure Reducing Pilot 1 10 11 2 12 13 3 4 5 14 15 6 7 16 8 Front View 9 Side View ITEM NUMBER DESCRIPTION 1 Adjusting Screw 2 Jam Nut 3 Spring Housing 4 Spring 5 Cap Screw 6 Body 7 Seat 8 O-Ring* 9 Bottom Cap 10 Spring Guide ITEM NUMBER DESCRIPTION 11 Nut 12 Belleville Washer 13 Diaphragm Washer 14 Diaphragm * 15 Yoke 16 Disc and Retainer Assembly* * Included in Repair Kit

Controls and Accessories Model CP-16 Downstream Surge Control 1 2 3 4 5 11 12 14 16 17 15 13 18 6 7 8 9 19 21 20 10 ITEM NUMBER DESCRIPTION 1 Adjusting Screw 2 Jam Nut 3 Spring Housing 4 Spring 5 Cap Screw 6 Shaft O-Ring* 7 Power Chamber 8 O-Ring * 9 Body 10 Seat 11 Spring Guide ITEM NUMBER DESCRIPTION 12 Upper Stem Nut 13 Belleville Washer 14 Upper Diaphragm Washer 15 Diaphragm * 16 Lower Diaphragm Washer 17 O-Ring * 18 Stem 19 O-Ring * 20 Disc and Retainer Assembly * 21 Lower Stem Nut * Included in Repair Kit

Installations Prior to installation, flush line to remove debris. Install valve horizontally in line (cover facing UP), so flow arrow matches flow through the line. Avoid installing valves 6 and larger vertically. Consult factory prior to ordering if installation is other than described. Install inlet and outlet isolation valves. NOTE: When using butterfly valves, insure disc does not contact control valve. Damage or improper valve seating may occur. Provide adequate clearance for valve servicing and maintenance. Install pressure gauges to monitor valve inlet and outlet pressure. If installation is subjected to very low flow or potentially static conditions, it is recommended a pressure relief valve (1/2 minimum) be installed downstream of the Pressure Reducing Valve for additional system protection. Start-Up Proper Automatic Control Valve start up requires bringing the valve into service in a controlled manner. All adjustments to control pilots and speed controls, if so equipped, should be made slowly, allowing the valve to respond and the system to stabilize. NOTE: Control Valves should be set up in a dynamic (flowing) condition for proper start up. Provisions for flow must be made to insure proper settings. For proper operation, the Surge Control Pilot is adjusted approximately 10 PSI higher than the Pressure Reducing Control. 1. 2. Close upstream and downstream valves to isolate the valve from line pressure. Release spring tension on Pressure Reducing Control by turning adjustment screw out (counterclockwise), decreasing setpoint. Increase spring tension on Surge Control Pilot by turning adjustment screw in (clockwise) to keep Surge Control Pilot closed while downstream pressure adjustments are made. Open all Isolation Ball Valves, if so equipped. If valve is fitted with adjustable speed controls, turn needle(s) in (clockwise) until seated, and return out (counterclockwise) 1 1/2 to 2 1/2 turns. These are approximate settings, and should be fine tuned to suit system requirements after pressure adjustments have been made. Slowly open upstream isolation valve to allow controlled filling of the valve. Vent entrapped air by carefully loosening control tubing or pipe plug at the highest point possible. If valve is equipped with a Position Indicator, open Air Bleed Petcock to vent air. Water will be milky in appearance and will begin to clear as air is vented. Carefully loosen enough cover screws on control pilot(s) to vent entrapped air. Re tighten when water vents clearly. 3. Setting Reducing Control: Slowly open downstream isolation valve. Gradually turn adjustment screw on the Pressure Reducing Control in (clockwise) to raise downstream pressure. Allow valve and system to stabilize. Observe inlet and outlet pressure gauges. Continue to adjust as needed, pausing approximately every 1 1/2 turns, allowing valve and system to stabilize. Turning adjustment screw clockwise raises outlet pressure. Turning adjustment screw counterclockwise lowers outlet pressure. Continue to adjust until downstream pressure is approximately 10 PSI higher than desired outlet pressure. 4. Setting Surge Control: While observing downstream pressure gauge (or Position Indicator), slowly turn Surge Control Pilot adjustment screw out (counterclockwise) until downstream pressure quickly falls. The Surge Control Pilot is set at the point when the valve begins to close. Tighten locknut on the Surge Control Pilot. Turn adjustment screw counterclockwise on Pressure Reducing Control until desired downstream pressure is achieved. Tighten locknut on Pressure Reducing Pilot. The Surge Control Pilot is set approximately 10 PSI higher than the Pressure Reducing Control. 5. Fine tune Speed Controls to suit system requirements. Adjust Closing Speed Control (if equipped) clockwise for slower closure, and counterclockwise for faster closure. Adjust Opening Speed Control (if equipped) clockwise for slower opening, and counterclockwise for faster opening.

Specifications The Pressure Reducing and Downstream Surge Control Valve shall be a pilot operated diaphragm valve designed to automatically reduce a fluctuating higher upstream pressure to a constant lower downstream pressure regardless of varying flow rate, and quickly modulate toward a closed position when a sudden high pressure downstream condition occurs. The main valve shall be a hydraulically operated, single diaphragm actuated, globe or angle pattern valve. Y-pattern valves shall not be permitted. The valve shall contain a disc and diaphragm assembly that forms a sealed chamber below the valve cover, separating operating pressure from line pressure. The diaphragm shall be constructed of nylon reinforced Buna-N, and shall not seal directly against the valve seat and shall be fully supported by the valve body and cover. Rolling diaphragm construction will not be allowed and there shall be no pistons operating the main valve or any pilot controls. The main valve body and cover shall be Ductile Iron ASTM A536, and all internal cast components shall be Ductile Iron or CF8M (316) Stainless Steel. All Ductile Iron components, including the body and cover, shall be lined and coated with an NSF 61 Certified Epoxy Coating applied by the electrostatic heat fusion process. All main valve trim and throttling components (cover bearing, valve seat and disc guide) shall be Stainless Steel. The valve body and cover must be machined with a 360-degree locating lip to assure proper alignment. The disc and diaphragm assembly shall contain a Buna-N synthetic rubber disc with a rectangular crosssection that is securely retained on 3-1/2 sides by a disc retainer and disc guide. Diaphragm assemblies utilizing bolts or cap screws for component retention will not be permitted. The exposed portion of the seat disc shall contact the valve seat and seal drip-tight. The disc and diaphragm assembly must be guided by two separate bearings, one installed in the valve cover and one concentrically located within the valve seat, to avoid deflection and assure positive disc-to-seat contact. Center guided valves will not be permitted. All necessary repairs shall be made from the top of the valve while the body remains in line. Pilot control systems for valves 3 and smaller shall contain a Flow Clean Strainer, Fixed Orifice Closing Speed, Adjustable Opening Speed Control, Downstream Surge Control Pilot and Pressure Reducing Pilot. Pilot control systems for valves 4 and larger shall contain an external Y-Strainer, Fixed Orifice Closing Speed, Downstream Surge Control Pilot, Pressure Reducing Pilot and Isolation Ball Valves on all body connections. All pilot control systems shall utilize copper tubing and brass fittings regardless of valve size. The adjustment range of the surge control pilot shall be 20-200 psi and the pressure reducing pilot shall be 30-300 psi. The valve shall be Watts ACV Model or pattern Combination Pressure Reducing and Surge Control Valve. Other Watts ACV Pressure Reducing Control Valves M115 / M1115 Pressure Reducing Valve M115-3 / M1115-3 Pressure Reducing Valve with Hydraulic Check Feature M115-74 / M1115-74 Pressure Reducing Valve with Low Flow By-Pass