ELECTRONIC FIREPLACE DAMPER

Similar documents
SYSTEM CONTROL KIT. Model: CK-41F. Designed for use with the SWG Series Power Venter for controlling Natural Gas or L.P. Gas appliances.

UV-AIRE AIR PURIFYING SYSTEM

II DISTRIBUTION & SUBSTATION TYPE C

Installation and Operation Guide for PD5100 Automatic Transfer Switch

Installation and Operation Guide for PD5200 and PD5300 Automatic Transfer Switch

MODERUSTIC Battery Operated Remote Control Electronic Safety Pilot System IPI Intermittent Pilot Light For Fire Pits or Fireplaces

Quick Connection Cabinet (QCC)

LEV/Wn Building A Connected World

Motorized Stainless 2-Way Valves

DIGIGAUGE P R E S S U R E D I S P L A Y S Y S T E M I N S T R U C T I O N M A N U A L

FADE Series Wall Axial Fans

HP190SL Series Slimline Radon Fans

Sawhorse with Chainsaw Holder

Model Numbers SAVI-NOTE75, SAVI-NOTE150


Power. On Your Terms.

10 Year Limited Warranty

Models: AFVK-SP-SPLIT AFVK-SP-H/L-SPLIT AFVK-SP-MH/L-SPLIT INSTALLATION AND OPERATING INSTRUCTION

Natural Gas Conversion Instructions for

SYSTEM CONTROL KIT. Model: CK-41F ITEMS INCLUDED IN KIT:

Smith & Hawken Propane Tank Cover dpci # stock # ZAZ15200T

Please read all of the installation instructions carefully before installing the product. Improper installation will void manufacturer s warranty.

Installation & Operation Manual. Electrak 100 Series / Electromechanical Linear Actuator

Installation Power Management Unit Battery Cables and Battery Harness

Adjustable Steel Welding Table

A/C PRESSURE MONITOR INSTALLATION INSTRUCTIONS SYSTEM OPERATION GREEN INDICATOR LIGHT

150-Lb. Drywall and Panel Hoist

Kit INSTALLATION GUIDE. For maximum effectiveness and safety, please read these instructions completely before proceeding with installation.

JD-2 TOLL FREE UG August /2011

1000-LB. MOTORCYCLE LIFT TABLE OWNER S MANUAL

PVI 1800/PVI Residential/Commercial Grid-Tied Photovoltaic Inverter WARRANTY MANUAL. Subject to Change REV , Solectria Renewables

Q35 Series Automatic Vent Damper System

AD-7 THERMAL INDICATING AMMETER

DUAL WIDEBAND AIR/FUEL RATIO GAUGE Product Numbers: GS-W702W_Dual, GS-C702W_Dual, GS-T702W_Dual

CTFRP Series Power Supplies

Heavy-Duty Welding Fabrication Table

AUTO-BLiP. User Manual Ford Mustang INTELLIGENT DOWNSHIFTS. Version 1.2

Installation & Operation Manual. Electrak 10 Series / Electromechanical Linear Actuator

AUTO-BLiP. User Manual Chevrolet Corvette. Version 1.2

Heavy-Duty Drywall Dolly Cart

INSTRUCTION MANUAL. 12-Station HD Shop 12V Portable Battery Charger

RANGE HOODS USER INSTRUCTIONS

GC-1. Roof and Gutter De-Icing Control Installation and Operating Instructions FOR EXTERIOR INSTALLATION ONLY

AUTO-BLiP. User Manual Lotus INTELLIGENT DOWNSHIFTS. Version 1.0

Installation & Operation Manual. Electrak 1 Series / Electromechanical Linear Actuators Limit Switch, & Potentiometer Feedback, and Long Life Models

User s Manual and Operating Instructions

Thermaltake Warranty / Support Information

Model NTX7 Series Automatic Battery Charger User s Manual Rev. 1.0 October 17, 2006

INSTALLATION & OPERATING INSTRUCTIONS: REVOLUTION SPINEBOARD ATTACHMENT WARNING

User s Manual and Operating Instructions

Woolich Racing. Bike Harness Installation Instructions Hayabusa Gen 2 (08+)

Installation Manual & Warranty

Adjustable Steel Drum Dolly

AUTO-BLiP. User Manual Chevrolet Corvette. Version 1.7

FLO Home TM G5 Model. Installation guide

1000-LB. ENGINE STAND

Safety Pilot System For Vented Gas Logs

WARRANTY POLICY. Grid-Tied Photovoltaic Inverters. Revision D. 2014, Solectria Renewables, LLC DOCIN

VICE MOUNTED BEAD ROLLER

G76x Direct Spark Ignition Controls

MODEL: 1410-A INSTALLATION AND OPERATION INSTRUCTIONS

60 Watt Industrial LED Low Bay Light

Grundfos Variable Speed GRUNDFOS INSTRUCTIONS. Installation and Operation

Woolich Racing. Bike Harness Installation Instructions Suzuki Harness Type 4a GSX1300R (Hayabusa)

EMISSION CONTROL WARRANTY STATEMENT

PATRIOT LIFT CO. ON-Lift Installation Guidelines

VP-4124/VP-4124-E 24/48 VOLT DC SWITCHING POWER SUPPLY

DRAIN WATER TEMPERING KIT

2000-LB. ENGINE STAND

Electric Chainsaw Sharpener With Bar Mount

MV Series Motors Operation & Parts Manual. Models M3V, M5V, M5V-US

Preassembled Clutch/Electrically Released Brake Module

INSTALLATION & OWNER'S MANUAL

Installation & Operators Manual

Installation Instructions

ROBERT H. PETERSON CO. AUTOMATIC REMOTE LIGHTING SAFETY PILOT SYSTEM WITH VARIABLE FLAME-HEIGHT REMOTE FOR NATURAL OR PROPANE GAS. Model APK-17(M)(P)

WINDOW AIR CONDITIONER SUPPORT BRACKET

Air Curtain. Installation, Operating and Maintenance Instructions

Heavy-Duty Sawhorse. Owner s Manual

MINISTICK TM UV Germicidal Ultraviolet Light

CurrentGuard. CurrentGuard. CurrentGuard. Plus. Surge Protective Devices. Installation,Operation and Maintenance Manual PN

MODEL RVS304. REMOTE CONTROLLED SAFETY PILOT KIT Supplemental Installation Instructions for use with Natural Gas Log Sets

PowerFLEX Module Limited Warranty Program

PVI 60KW, PVI 82KW, PVI 95KW

Users Guide for Ac-sync

GRUNDFOS INSTRUCTIONS. Grundfos ALPHA Installation and operating instructions

4-SIDED HOCKEY SCOREBOARD LED BAR DIGIT INSTRUCTION MANUAL REVISION DATE: PART#:

6. Electrical. 7. Settings. 8. Quick

Hazardous Location Direct-Drive Exhaust Fans. Operating Instructions & Parts Manual

GeniSys 24V. Model Advanced 24 Vdc Burner Control. Description / Applications

Installation / Operation Instructions Sunnex ORION Series Exam Lights

HIGH PERFORMANCE FUEL DELIVERY KIT DUAL STOCK PUMP VERSION L & L

Garden Hose Reel with 3/4In. x 100Ft. Hose. Owner s Manual

Care and use guide. Contents. page

HIGH VOLTAGE DIGITAL AMMETER

Model Numbers: MAC-36-BDF, MAC-42-BDF, MAC-48-BDF CONSUMER: READ AND SAVE THESE INSTRUCTIONS

CA 5054 Owner s Guide

OWNER S MANUAL AND INSTALLATION INSTRUCTIONS

AEROMOTIVE Part # A2000 Fuel Pump Kit INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS FOR PCBM-36C CONVERSION KIT From Natural Gas to Propane/LP Gas

Transcription:

ELECTRONIC FIREPLACE DAMPER Model: FSE Low Profile Series The Flue Sentinel Electronic Fireplace Damper is designed to increase the comfort and energy efficiency of residential homes with gas-fired fireplaces. Consisting of a stainless steel pipe/blade assembly and solid-state controller housed in a weather-proof enclosure, the damper is installed outdoors on the top of the chimney of a gas-fired fireplace. The damper automatically opens the flue outlet when the fireplace is turned on and automatically closes off the flue outlet when the fireplace is turned off. By closing off the flue outlet the fireplace is not in use, the damper prevents drafts and conserves energy by preventing heat in the home from escaping through an open flue. The Flue Sentinel is design certified by the Canadian Standards Association (CSA) to CSA Requirement No. 2.03- US for Automatic Vent Damper Devices for Use Outdoors on Fireplace Chimneys and is covered by U.S. Patent No. 6,915,799. WARNING: Do NOT install this damper on a chimney burning solid fuel such as wood. Do NOT install this damper on a chimney used for venting central heating or water heating appliances. READ THESE INSTRUCTIONS CAREFULLY AND COMPLETELY BEFORE PROCEEDING WITH THE INSTALLATION. This device MUST be installed by a qualified agency in accordance with the manufacturer's installation instructions. The definition of a qualified agency is: any individual, firm, corporation or company which either in person or through a representative is engaged in, and is responsible for, the installation and operation of HVAC appliances, who is experienced in such work, familiar with all the precautions required, and has complied with all the requirements of the authority having jurisdiction. Please retain these instructions after installation. Installed By: Phone: Installation Date: MFG BY: www.fieldcontrols.com

SPECIFICATIONS Voltage (Range) Frequency Current (running) Maximum current rating for output circuit Operating Temperature Range Timing OPERATING SPECIFICATIONS 24VAC (Max 27.6, Min 20.4 VAC) 50/60 Hz 80 ma 5A Controller: (-40) - 140 F Pipe: (-40) - 650 F 7 seconds to open 30-40 seconds to close (incl. time delay) Flue Sentinel Dimensions, Weights and Clearances MODEL DIM A DIM B DIM C DIM D WT. (LB) Damper Blade Clearance Required FSE-L6 5.9 6.0 14.5 11.8 4.02.25 FSE-L8 7.9 6.0 16.5 13.8 4.25 1.25 FSE-L10 9.9 6.0 18.5 15.8 5.25 2.25 FSE-L11 10.9 6.0 19.5 16.8 5.81 2.75 FSE-L12 11.9 6.0 21.5 17.8 6.36 3.25 FSE-L13 12.9 6.0 22.5 18.8 6.55 3.75 FSE-L14 13.9 6.0 23.5 19.8 7.07 4.25 FSE-L16 15.9 6.0 25.5 21.8 8.25 5.25 FSE-L18 17.9 6.0 27.5 23.8 9.80 6.25 FSE-L20 19.9 6.0 29.5 25.8 11.25 7.25 FSE-L22 21.9 6.0 31.5 27.8 12.35 8.25 FSE-L24 23.9 6.0 33.5 29.8 13.75 9.25 *All dims are in inches page 2

INSTALLATION The Flue Sentinel has been designed to fit a variety of chimney types including masonry and manufactured chimneys. It features a mounting collar that seals the chimney, adjustable legs for means of attachment and a crimped outlet for mounting the chimney top. Figure 1 is an example of a typical installation Installation of the Flue Sentinel must comply with the following requirements The Flue Sentinel must be installed only on a factory built chimney or vent complying with a recognized standard, or a masonry or concrete chimney acceptable to the authority having jurisdiction. The Flue Sentinel must be located on a chimney so that it serves only the single fireplace appliance for which it is installed. The Flue Sentinel shall be installed in accordance with local codes, or in the absence of local codes, in accordance with the National Fuel Gas Code, ANSI Z223.1. If the Flue Sentinel is to be installed on an air-cooled chimney, it must be installed with the appropriate Flue Sentinel Mounting Kit per the kit instructions. Installation Steps: 1. Set the damper in the opening of the chimney flue to check the fit. The damper s mounting collar should rest evenly on the top edge of the flue. Also check the orientation of the damper control housing and mounting legs to ensure the proper attachment and routing of the wiring harness. 2. Remove the damper and apply a bead of high temperature sealant on the top edge of the flue. 3. Center the damper in the opening of the chimney flue. 4. Adjust the mounting legs to rest on top of the chimney and secure with screws. Tighten the mounting leg bolts at the collar brackets. 5. Install the chimney top and secure per the manufacturer s instructions. 6. Install the warning tag on the damper wiring harness near gas valve. To identify the requirement that the Flue Sentinel device be removed before converting to wood burning. Notes Ignition Module not shown. 120/24V Transformer *4-Wire Cable *Typically 18/4. Run in conduit if required or if installed on exterior of masonry chimney. **The Flue Sentinel is electrically interlocked with the main burner valve/controls of the gas log set. See Basic Wiring Diagram on pg. 5. On/Off Switch Chimney Top Flue Sentinel Mounting Leg Facade 2" x 4" Framing 1/2" Drywall or Sheetrock (See Local Code) Manufactured Chimney Chase Minimum Clearance to Combustibles Per Chimney Manufacturer Gas Log Set **Gas Valve Gas Line Figure 1 page 3

WIRING WARNING: This damper device MUST be interlocked with all automatic gas valves on the fireplace appliance. DO NOT negate the action of any existing safety of operational control. The following requirements must be met to ensure safe and proper operation: The Flue Sentinel Electronic Fireplace Damper must be electrically connected to the fireplace appliance using the chimney upon which the damper is installed. The damper must be installed in accordance with the NEC NFPA 70 (most recent edition) and/or local codes. The damper must be installed using the wiring harness supplied with it. This harness has a mated connector which plugs into the damper controller. The damper s wiring harness must terminate at the gas valve. Install the warning tag on the damper wiring harness near gas valve. To identify the requirement that the Flue Sentinel device be removed before converting to wood burning. The wiring connecting the damper controller to the gas valve must be a minimum of 18 AWG and must be run in conduit if installed on the exterior of the chimney or required by code. Figure 2 is a wiring connection diagram for a typical installation with an intermittent ignition system. The damper control wiring must always be connected as follows: Brown - 24 VAC Hot Orange - Signal In Yellow - Signal Out Black - 24 VAC Common D Figure 2 IGNITION CONTROL MODULE 24V GND TH-W GAS VALVE SPARK ELECTRODE/ SENSOR TRANSFORMER L1 120 VAC 24 VAC L2 FIREPLACE SWITCH HARNESS COLOR CODE Standard Wire Connector 2 4 High Temp Wire Connector 2 4 1 3 1 3 FLUE SENTINEL ELECTRONIC FIREPLACE DAMPER BLACK BROWN ORANGE YELLOW page 4 VIEW SHOWING END OF RECEPTACLE WIRE CONNECT CODE COLOR 1 BROWN 2 ORANGE 3 YELLOW 4 BLACK VIEW SHOWING END OF RECEPTACLE WIRE CONNECT CODE COLOR 1 WHITE 2 RED 3 GREEN 4 BLACK

SEQUENCE OF OPERATION When the fireplace is turned on, a 24V signal is sent by the fireplace control to the damper controller. The damper controller motor then rotates the damper blade, which is indexed to a cam, to the open position to allow products of combustion to pass through the flue outlet. The cam proves the damper is in the open position and switches 24V from the motor to the main gas valve or ignition system, which fires the main burner. When the fireplace is turned off, the fireplace control removes the 24V signal to the damper controller, shutting off the main burner. After a 30-40 second delay, the damper controller motor then rotates the damper blade to the closed position and resets itself for the next time the fireplace is turned on. FINAL INSPECTION WARNING: If a damper was installed prior to installing the Flue Sentinel, this damper MUST be blocked completely open or removed. CAUTION: Do NOT turn damper by hand. Manually rotating the Flue Sentinel damper will damage the motor and void the warranty. Turn on the gas and electrical supplies to the appliance. Check the operation of the Flue Sentinel by cycling the appliance at least three times as follows: 1. Switch the fireplace control to turn on the fireplace. 2. The damper will open and fire the main burner. The damper must be in the open position when appliance main burner is operating. 3. Switch the fireplace control to turn off the fireplace. The main burner will immediately shut off and, after approximately 30-40 seconds, the damper will rotate to the closed position. If the Flue Sentinel Electronic Fireplace Damper and/or fireplace appliance does not operate as described above, consult the Troubleshooting Chart below for the proper course of action to resolve the problem. page 5

TROUBLESHOOTING CHART PROBLEM POSSIBLE CAUSES ACTION Damper won t open No power or insufficient power at damper No signal into damper Obstruction preventing damper blade from rotating Defective damper controller Check for opens in the power supply circuit and correct Check for opens in fireplace control/circuit and correct Check for protruding screws or binding in pipe/blade assembly and correct Replace controller Damper opens but appliance main burner(s) does not fire Damper rotates continuously Damper won t close, main burner off Defective gas valve or ignition control on appliance Defective damper controller Defective damper controller No power or insufficient power at damper Obstruction preventing damper blade from rotating Check for power at gas valve and/or ignition control. If present, replace defective part If not present, check for power at controller, yellow wire should be energized. If not, replace controller Replace controller Check for power at controller, only black and brown wires should be energized. If not, check wiring diagram Check for protruding screws or binding in pipe/blade assembly and correct Damper won t close, main burner on Defective damper controller Fireplace control still sending signal to damper to open Replace controller Check for shorts in fireplace control/circuit and correct MAINTENANCE CAUTION: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. The Flue Sentinel has been designed to provide years of maintenance free service. However, for continued safe operation, the Flue Sentinel, chimney and fireplace appliance should be examined once a year by a qualified service agency. It is also recommended that the homeowner examine these components at least every (6) months, with particular attention given to deterioration from corrosion or other source page 6

LIMITED WARRANTY Field Controls, LLC ( Company ) warrants that its products shall be free from defects in material and workmanship under normal use for the limited period indicated, from the date of installation, subject to the provisions 1-8 below. Eighteen (18) months All Field Controls Products (except for those listed below as 5 years, 90 days or 24 months). Five (5) years Field Controls Direct Vent Systems (FDVS), Field Oil Vent Kits (FOVP), and ComboVents (CV). Ninety (90) days Uv lamps/bulbs Twenty four (24) months Flue Sentinel Chimney Dampers Provisions: 1. During the limited warranty period, Company, or its authorized service representative, will repair or replace, at Company s option, without charge, a defective Product. Product that is repaired may be repaired with new or refurbished replacement parts. Product that is replaced may be replaced with a new or refurbished product of the same or similar design. Company will return repaired or replacement Product to customer in working condition. Labor charges are not covered as part of the limited warranty. 2. With regard to UV lamps/bulbs, customer shall be required to include a "valid proof of purchase" (sales receipt) identifying the Product purchased (Product model or accurate date code information) and the date the Product(s) was purchased. 3. Product whose warranty/quality stickers, Product serial number plates or electronic serial numbers have been removed, altered or rendered illegible shall not be covered under the limited warranty. 4. Defective Product must be returned to Company, postage prepaid. 5. IN NO EVENT SHALL COMPANY BE LIABLE FOR ANY INDIRECT, SPECIAL, INCIDENTAL, CONSEQUENTIAL, OR SIMILAR DAMAGES (INCLUDING, BUT NOT LIMITED TO, LOST PROFITS OR REVENUE, INABILITY TO USE PRODUCT, OR OTHER ASSOCIATED EQUIPMENT, THE COST OF SUBSTITUTE EQUIPMENT, AND CLAIMS BY THIRD PARTIES) RESULTING FROM THE USE OF PRODUCT. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. 6. THIS WARRANTY AND REMEDIES ARE EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES, REMEDIES AND CONDITIONS, WHETHER ORAL, WRITTEN, EXPRESS, STATUTORY OR IMPLIED. TO THE EXTENT PERMITTED BY LAW, COMPANY DISCLAIMS ALL IMPLIED AND STATUTORY WARRANTIES, INCLUDING WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. 7. Company makes no warranty of any kind in regard to other manufacturer s products distributed by Company. Company will pass on all warranties made by the manufacturer and where possible, will expedite the claim on behalf of the customer, but ultimately, responsibility for disposition of the warranty claim lies with the manufacturer. 8. Product that has been subjected to misuse, accident, shipping or other physical damage, improper installation or application, abnormal operation or handling, neglect, fire, water or other liquid intrusion are not covered by the warranty. page 7

MFG BY: Phone: 252.522.3031 Fax: 252.522.0214 www.fieldcontrols.com Field Controls, LLC P/N 80000002 Rev A 01/14