USER GUIDE. Model RH10 Hygro Thermometer. Humidity and Temperature Meter

Solar Power Light Meter

USER MANUAL. 200A AC Mini Clamp Meter. Model MA130. Please visit for user manual translations

USER MANUAL. White LED Light Meter. Model LT40. Additional User Manual Translations available at

Hot Wire CFM/CMM Thermo-Anemometer

USER GUIDE Moisture Meter

Non-Contact Phase Rotation Tester

USER MANUAL. Insulation Tester + DMM. Model MG320

User Guide. Model Insulation Tester / Megohmmeter

GENERAL INFORMATION. H-1649, H-1650, H-1651 H-1653, H-1654 Easy-Count. uline.com. that may hurt accuracy:

User's Guide. CO 2 Meter. Model CO250

Model Insulation Tester / Megohmmeter. User Manual

User Guide. Model Insulation Tester / Megohmmeter

Non-Contact Phase Rotation Tester

USER MANUAL. 10KV Digital High Voltage Insulation Tester. Model MG500. Additional User Manual Translations available at

Model Battery Powered Milliohm Meter

User's Guide. Model RPM10 Laser Photo / Contact Tachometer with IR Thermometer. Introduction

User's Guide. EzFlex Thermo-Anemometer. Model EZ30 UNITS MAX MIN AVG VEL

l The Battery Tester is designed for measuring the l AC four-terminal method to measure the internal

Valor 1000W Series Instruction Manual. Serie Valor 1000W Manual de Instrucciones. Série Valor 1000W Guide de I utilisateur

ECscan30 Pocket Conductivity/TDS Tester Instruction Manual

User Guide. Model Insulation Tester / Megohmmeter. Introduction

INTRODUCTION. Backlight for operating in dark area Low battery indicator Auto power off function. CO levels and its effect

CP900EPFCLCD User s Manual K

Atlas 5. Instruction Manual. Handheld Indoor Air Quality Monitor. Measures CO2, Temperature and Humidity DISTRIBUTED BY

Solar Hybrid Power Generating System CPS1200EOH12SC CPS2200EOH24SC CPS3000EOH24SC. User s Manual K01-C

Breath Alcohol Tester

ECscan20 Pocket Conductivity Tester Instruction Manual

TS-PFS. User s Guide. Portable Feeder Scale For Weigh Session Totals. Totalized Weight Item Weight Item Count Nonvolatile Memory. Guide version 1.

Power Inverter. User s Manual. Diamond Series CPD1200EILCD

PHscan30S Pocket ph Meter Instruction Manual

DLS-TP400 USER S MANUAL

User's Manual. Earth Ground Resistance Tester. Model Introduction

MPT-250B SPECIFICATIONS AND OPERATING INSTRUCTIONS

AT8020. Breath Alcohol Tester. Using manual. Ver:HW

CruzPro. RPM, Engine Hours, Elapsed Time Gauge RH110. Other CruzPro Products

PN# A,13-316A,13-317A, , , & TireGard

ORPscan20 Pocket ORP Tester Instruction Manual

FOR YOUR PERMANENT FILE

User's Manual. High Voltage Megohmmeter. Analog Insulation Tester plus AC Voltage and Continuity Tests. Model

OWNERS MANUAL POWER PACK 44AH. Part No. COMPBI012. Australia s original Outdoor brand

CONTENTS. Introduction. Thank you for purchasing the AlcoSense Precision+ breathalyser.

TDSscan10M Pocket TDS Tester Instruction Manual

Salt 1 Pocket Salinity Tester Instruction Manual

AT8060 BREATH ALCOHOL TESTER USING MANUAL. Ver: HW Catalogue

EC20 Pocket Conductivity Tester Instruction Manual

PIECAL 520B & 521B Thermocouple Source Operating Instructions

SL101 Manual_SL101 User Manual 05/10/ :06 Page 1. Instruction Manual

Mini Multimeter with Non-Contact Voltage Detector (NCV)

BAPI-Stat 4 Room Humidity Sensor (BA/ B4 -H200 Series)

ECscan40 Pocket Conductivity/TDS/Salinity Tester Instruction Manual

Phase Sequence Tester

PC60 Premium Multi-Parameter Tester (ph/ec/tds/salinity/temp.) Instruction Manual. APERA INSTRUMENTS, LLC V6.4

Model 322 Automated Thermocouple Calibrator Operating Instructions. Product Description. Practical Instrument Electronics

Continental Hydraulics Installation Manual CEM-AA-A

R & D SPECIALTIES ROTROL I USER'S MANUAL

DT304. Digital Temperature Logger INSTRUCTION MANUAL

STP116 STP188. Tyre Pressure Monitoring System. User manual

βeta 20A AUTO 12V/24V SOLAR CHARGE CONTROLLER WITH REMOTE METER

Owners Manual for TPMS plus GPS

SERVICE MANUAL. STARTER Portable Meter ST300 ST300C ST300D ST400D. Ohaus Corporation, 7 Campus Drive, Suite 310, Parsippany, NJ (973)

HI Ethylene Glycol Refractometer INSTRUCTION MANUAL

testo 535 Instruction manual

PIN-TYPE LCD MOISTURE METER

CA 6550 Owner s Guide

i-stat 1 Analyzer 2 Before You Use the Analyzer

PR1000ELCD / PR1500ELCD User s Manual

Valve stems pictured may differ from stems packed in kit.

Digital Electronic Torque Wrench. Operating Manual. Model 60648

Operating Guide TSFS-300 Air Parcel Conveyor Scale With automatic totalizing

True RMS Autoranging Multimeter

D Dräger Alcotest 3000 Breath Alcohol Measuring Device

NON MAINTAINED TWIN SPOTLIGHT WALL MOUNT LED EMERGENCY LIGHT

CO 2 Room Sensor in the BAPI-Stat Quantum Prime Style Enclosure

SFA275 USER MANUAL PLEASE READ THIS USER MANUAL COMPLETELY BEFORE OPERATING THIS UNIT AND RETAIN THIS BOOKLET FOR FUTURE REFERENCE

Breath Alcohol Tester

NGW & HGW SERIES CONTENTS OPERATION MANUAL CAUTIONS HIGH RESOLUTION MULTI-FUNCTION DIGITAL SCALE 1. INSTALLATION 2. SPECIFICATIONS

TPMS TP200 USER S MANUAL

MODEL. TI-500 RF Series. User Manual. Digital Weight Indicator (with wireless weighing capability)

FL-100-R (109) Operations and Installation Manual

ITA / ITB - AS / AP / AP SERIES Electronic Table Top Weighing Balance

IMPORTANT. Always connect the batteries first. Use for 12V battery system only 12V (36 cells) solar panel array.

PIECAL 322 Automated Thermocouple Calibrator Operating Instructions. Product Description

Key Features: Visual and audible warnings Set desired PSI levels Adjustable windshield mount included

CruzPro. Volts Amps Amp-Hour Monitor VAH110. Other CruzPro Products. website:

Level-Up Motorhome Leveling

EGQ 212: Duct transducer, CO 2 and temperature

HI Portable Waterproof Skin ph Meter INSTRUCTION MANUAL

LBC Series Battery Charger Instructions

T R A N S F O R M I N G T E C H N O L O G I E S, L L C O U T S T A N D I N G A L T E R N A T I V E S I N S T A T I C C O N T R O L

INSTRUCTION MANUAL. Mi490 Peroxide value. Milwaukee Lab Photometer. Test Equipment Depot Washington Street Melrose, MA 02176

Operating Instructions. TEK 678 Display Unit with remote and 10 bar display

SmarTire TPMS Maintenance Hand Tool. Revision User Manual

BATTERY CHARGER RS-1000 Instruction Manual

CO 2 Room Sensor in the BAPI-Stat 3 Enclosure with Common Ground Configuration

User's Manual Digital High Voltage Insulation Tester Model

User's Guide. Vane Anemometer. Model Measures Air Velocity & Temperature. Degrees C/F switchable

Mini Multimeter with Non-Contact Voltage Detector (NCV)

ADTFM-im -issue INSTRUCTION MANUAL DIGITAL DIESEL METER ADTFM

Engineering Standards. Engineering Standard Number C A. Name. Digital Oxygen Remaining System O2 REMAINING

Transcription:

USER GUIDE Digital Formaldehyde Meter Model FM100

Introduction EXTECH INSTRUMENTS Thank you for selecting the Extech Instruments Model FM100. The FM100 measures Formaldehyde CH 2 O (HCHO) concentration, Air Temperature, and Relative Humidity. The alarm feature alerts the user when the Formaldehyde 0.08ppm limit is exceeded. The FM100 can be wall mounted or used as a table top device. This device is shipped fully tested and calibrated and, with proper use, will provide years of reliable service. Please visit our website (www.extech.com) for the latest version of this User Guide, Product Updates, and Customer Care. Features Alternately displays Formaldehyde concentration, Air Temperature, and Relative Humidity at 6 second intervals Bright multicolor LED displays green for safe HCHO levels, yellow for caution, and red for danger Alarm display icon and audible beeper alerts user when Formaldehyde concentration limit of 0.08ppm is exceeded Selectable Formaldehyde unit of measure ppm or mg/m 3 ZERO calibration function Manual temperature and Relative Humidity compensation Designed with electrochemical CH 2 O (HCHO) sensor Low battery indicator Meter Description 1. Offset adjustment potentiometer 2. Control Button 3. AC Power Adaptor Port 4. LCD Display 5. Multi color LED Indicator 1 2 3 4 5 Note: Battery compartment, tilt stand, and wall mount located on rear of meter. 2 FM100 en GB_v1.6 12/14

Operation Powering the meter EXTECH INSTRUMENTS If the meter is supplied without batteries installed, install the supplied batteries in the rear battery compartment to power the meter. Please observe proper polarity. If the meter is supplied with the batteries installed, and a protective battery strip is installed in the battery compartment, remove the protective strip to power the meter. Alternatively, plug an AC adaptor into the jack on the side of the meter and then into an AC power source to power the meter. Normal Operating Mode When switched ON, the LCD displays 0000 for a period of time, depending on the time that the meter has been inactive. The meter will then proceed to the normal mode of operation where the LCD displays the current HCHO level in ppm, the Temperature ( C/ F), and RH% (relative humidity) alternately at 6 second intervals. Multi Color Status Indicator LED The Front panel status LED uses a color coding system to inform the user as to the measured HCHO concentration. Green for Good; Yellow for Hazard; Red for Danger. If the LED fails to illuminate please return the unit for service. Alarm indication When the Formaldehyde limit of 0.08ppm is exceeded the meter audibly beeps and flashes an alarm icon on the LCD. Refer to the CONTROL BUTTON section to learn how to silence the beeper. Control Button The Control button located on the left side of the meter is used to control and program a variety of meter functions. Press and hold the Control button to enter the function mode. Repeated presses of the control button cycle through the available parameters. These parameters, in order, are: ZERO Calibration Temperature Unit selection ( C/ F) Temperature compensation (used in conjunction with side potentiometer adjust) Humidity compensation (used in conjunction with side potentiometer adjust) Unit of measure change (ppm or mg/m 3 ) Alarm Beeper ON/OFF Factory Default setting reset Escape/Return (abort operation and return to normal operation) Note: A removable cover protects the offset adjustment and prevents unintentional adjustment. Remove the protective cover to perform an offset adjustment. 3 FM100 en GB_v1.6 12/14

EXTECH INSTRUMENTS ZERO Calibration Ensure that calibration is performed in a clean air environment (no VOCs or HCHO gases). Press and hold the control button for 3 seconds (until appears on the LCD screen). Press and hold the button again to start calibration. Release the control button and wait 300 seconds for the calibration to complete. The meter will display END for 2 seconds when calibration is complete and will then return to the normal mode of operation. Changing Temperature Units o C/ o F When is shown on the display, press and hold the control button to display the current temperature unit. Momentarily press the Calibration control button to toggle C and F units. To save setting, press and hold the control button. The meter will return to the normal mode. Temperature Compensation Adjustment When is shown on the display, press and hold the control button. The factory default 0.0 value will flash. Turn the compensation potentiometer clockwise to increase the temperature offset or counterclockwise to decrease offset). The range is 5.4 F to +5.4 F ( 3.0 C to +3.0 C). When done, press and hold the control button to save the setting. The meter will return to the normal measurement mode and will reflect the offset when temperature readings are displayed. 4 FM100 en GB_v1.6 12/14

EXTECH INSTRUMENTS Relative Humidity Compensation Adjustment When is shown on the display, press and hold the control button to enter the relative humidity compensation adjustment mode. Momentarily press the control button to make a step change in the RH% offset; the range is 9 to +9 RH %. When done, press and hold the control button to save the setting. The meter will return to the normal mode. Warning: While performing the compensation adjustments, do not touch the sensor, as accuracy may be lost when adjusting the temperature values. Warning: While performing temperature or RH% compensation adjustments do not touch the slotted openings on the meter housing, these are where the sensors are located. Otherwise, accuracy may be compromised. Change Formaldehyde Unit (ppm or mg/m 3 ) When is shown on the display, press and hold the control button to enter the unit selection mode. Choose the units (ppm or mg/m 3 ) by momentarily pressing the control button. Once the desired units are chosen, press and hold the control button to save the setting. The LCD display will return to the normal measurement mode. Beeper Activate or Inactivate Selection When is shown on the display, press and hold the control button to enter the alarm (beeper) setting mode. Momentarily press the control button to toggle the beeper condition ON or OFF. Once selected, press and hold the control button to save and return to the normal mode of operation. 5 FM100 en GB_v1.6 12/14

EXTECH INSTRUMENTS Revert to Factory Default Settings When is shown on the LCD display, press and hold the control button to reset the meter to its default (factory) settings. Escape/Return Function When is shown on the LCD display, press and hold the control button for 3 seconds to abort the current programming step and return to the normal measurement mode. Maintenance Low Battery Condition and Battery Replacement When the battery icon ( ) appears on the LCD, the batteries must be replaced. If the meter is low on battery voltage, erratic or inaccurate readings may result. Never use the meter with the low battery icon displayed. The battery compartment is on the back of the instrument. Slide the battery compartment cover off of the meter to access the batteries. Replace the 4 AAA batteries observing proper polarity and replace the compartment cover before switching the meter ON. Battery Safety Reminders o Please dispose of batteries responsibly; observe local, state, and national regulations. o Never dispose of batteries in a fire; batteries may explode or leak. o Never mix battery types; install new batteries of the same type. Never dispose of used batteries or rechargeable batteries in household waste. As consumers, users are legally required to take used batteries to appropriate collection sites, the retail store where the batteries were purchased, or wherever batteries are sold. Disposal: Do not dispose of this instrument in household waste. The user is obligated to take end of life devices to a designated collection point for the disposal of electrical and electronic equipment. 6 FM100 en GB_v1.6 12/14

Display Error Codes The following errors may appear on the display: EXTECH INSTRUMENTS E 1: HCHO readings are outside of the specified measurement range E 2: Temperature readings are outside of the specified measurement range E 3: Relative Humidity (RH %) readings are outside of the specified measurement range Specifications Display Multifunction LCD; Dimensions 48 x 28mm (1.89 x 1.10 ) Front Panel LED indicator Green for normal, yellow for caution, and red for danger Formaldehyde CH 2 O (HCHO) measurement range 0.00 to 5.00ppm (mg/m 3 ) HCHO accuracy ±5% of reading +0.03ppm (baseline drift) Accuracy Note: Accuracy meets NIOSH acceptance criterion within ±25% of the true value at 95% confidence level Air Temp. Measurement range Air Temperature Resolution Air Temperature Accuracy Relative Humidity range RH Resolution 0 C to 50 C (32 F to 122 F) 0.1 C (0.1 F) ±1.0 C (1.8 F) 20 to 90%RH 1% RH Relative Humidity Accuracy ±5% Power AAA batteries x 4 pcs or universal AC adaptor (included) Meter dimensions 113 x 108 x 53mm (4.4 x 4.3 x 2.1 ) Weight 159g (5.6 oz.) Copyright 2014 FLIR Systems, Inc. All rights reserved including the right of reproduction in whole or in part in any form www.extech.com 7 FM100 en GB_v1.6 12/14