VRN Dynamic Pressure-Regulating Control Valves and Actuators

Similar documents
VBN Threaded Control Ball Valves and Actuators

NETSIAN TECHNOLOGY VALVE SCHEDULE

Selection Guide. Vx-2x13-5xx-9-xx Series Vx-2x13-8xx-9-xx Series VB-2x xx Series. Schneider Electric Ball Valve Assemblies

PIC-V Valve... 1 Unimizer (1/2 to 3 )... 2 Unimizer (4 to 6 )... 3 Automizer... 4 MVP Valve... 5

VA, VF, and VS Series Direct Mounted Globe Valve Assemblies. Application. Features

MS4104, MS4109, MS4604, MS4609, MS8104, MS8109 Fast-Acting, Two-Position Actuators

M9203-xxx-2(Z) Series Electric Spring-Return Actuators

Technical Documentation Pressure Independent Characterized Control Valves (PICCV) Patented Effective December 2007

P2050S-030, 1/2, Electronic Pressure Independent Valve Stainless Steel Ball and Stem, Female NPT Ends

VA9104-xGA-1S Series Electric Non-Spring Return Valve Actuators

Zone Valves and Parts (Honeywell)

pressure independent characterized control tm

M9203-xxx-2(Z) Series Electric Spring Return Actuators

VA9104-xGA-2S Series Electric Non-Spring Return Valve Actuators

P1000 Series Pressure Independent Valves

MX4X-6XXX Series MX4X-7XXX Series. Selection Guide. Applications. DuraDrive Series Actuators and Accessories

Non-Spring Return EconoDrive Floating Actuator

ML6420, ML7420 Non-Spring Return Electric Linear Valve Actuators

DA-053 Series. Overview. Applications. Features & Benefits. Datasheet. 53lb-in (6 Nm), Non-Spring Return Damper Actuators

Simple Set COMMERCIAL. Pressure Independent Control Valves 2 Way 1/2-2 02/16/18 COMMERCIAL

Product Cross Reference

M9208-xxx-x Series Electric Spring Return Actuators

M9208-xxx-x Series Electric Spring Return Actuators

VBN Control Ball Valve Quick Selection Guide. Cover Every Application With One Control Ball Valve Brand

VBN2, VBN3 Control Ball Valves With Threaded Connections

Hose Length Custom Length Supply Line Options Ball Valve w/ PT UBY Strainer w/ PT and BDV

M9208-xxx-x Series Electric Spring-Return Actuators

N05, N10 SERIES NON-SPRING RETURN DIRECT-COUPLED DAMPER ACTUATORS FOR FLOATING AND TWO-POSITION CONTROL

M9220-xxx-3 Electric Spring Return Actuators

ComfortPoint Programmable Lon, VAV/Unitary Controllers

VA9208-xxx-xx Series Electric Spring Return Actuators

M9220 Series Electric Spring-Return Actuators

NV Direct Coupled Globe Valve Actuator

Features Globe Valve 2-Way & 3-Way Assembly Features:

S10010 / S SPRING RETURN DIRECT-COUPLED DAMPER ACTUATORS 10/20 Nm (88/177 lb-in) FOR MODULATING AND FLOATING CONTROL SPECIFICATIONS GENERAL

VA2202-xxx-2 Series Electric Spring Return Valve Actuators

Versatile and Powerful

ML6425, ML7425 Spring Return Electric Linear Valve Actuators

S1024-2POS / S POS S2024-2POS / S POS

LF24-SR US TF24-SR US TFX24 US LF24 US. B3 B Three-way Characterized Control Valve, Chrome Plated Brass Ball and Brass Stem

20 to 150 mm 2-Way Automatic Flow Balancing Control Ball Valves

MS Application. Features. Proportional Valve Actuator General Instructions

Minimum 27 in-lb torque

COMMERCIAL. Product PRofile

Flowrite 599 Series SAX Electronic Valve Actuator Non-spring Return, 24 Vac, 3-Position Control

Commercial Actuator Selection Chart Non-Spring Return

VE VVG Series Electronic Two-way Valves Normally Closed

VA-640GSX024P. Overview. Applications. Features & Benefits. Datasheet. Large Globe Valve Actuators

D24-53 Series Electric Non-Spring Return Actuators 53 lb in Models (6 N m)

VB-8000 Series VB-9313 Series. Selection Guide. Applications. Applicable Literature. Selection Guide Contents. Valve and Actuator Selection Procedure

M436A/M836A,B Damper Motors

VA9208-xxx-xx Series Electric Spring-Return Actuators

Pressure Independent Control Valve Applications for Building Automation, Temperature Controls, and HVAC Two-Way Chilled Water Hot Water

M9210-xxx-3 Electric Spring Return Actuators

LMB24-3 (-S)(-T) On/Off-Floating Point Control, Non-Spring Return, Direct Coupled, 24 V

Mount directly to 1.05 jackshafts. (new ZG-120 bracket shown) EFB24-S N4, EFX24-S N4(H) EFB24-S, EFX24-S (p. 21)

VA9203-AGx-2Z Series On/Off and Floating Point Electric Spring Return Valve Actuators

AMB24-3(-S) On/Off-Floating Point Control, Non-Spring Return, Direct Coupled, 24 V

ML6420, ML7420 Non-Spring Return Electric Linear Valve Actuators

TAC DuraDrive Product Guide Direct Coupled Actuators

VGF Flanged Globe Valves

ATi Max Series. Pressure Independent Control Valves 2 Way 2-1/2-6

M9116, M9124, and M9132 Series Electric Non-spring Return Actuators

OpenAir Electronic Damper Actuators GLB Series Enhanced Non-spring Return Rotary

Minimum 27 in-lb Torque

Technical Instructions Document No EA GQD May 6, OpenAir GQD Series. Spring Return, 20 lb-in (2 Nm), Rotary Electronic Damper Actuators

LF Series Spring Return Direct Coupled Actuator

MS4120F, MS4620F, MS8120F, S2024-F, S20230-F Fast-Acting, Two-Position Actuators

OpenAir Electric Damper Actuator GDE/GLB Series Non-spring Return, 24 Vac Floating Control, Rotary

B2/B3 Series Characterized Control Valve, Non-Spring Return Actuator

SAX Electronic Valve Actuator

2006 Product Range Overview. Belimo Project: One Bellevue Center, Seattle, Washington

MF-22xx3. Application. Features. Floating Valve Actuator General Instructions

High temperature characterized control valves

Flowrite Globe. Pneumatic 4-inch Valve Actuator. Valves. Description. Applications. Features D-141.

FlowCon SM mm. Dynamic Self Balancing Control Valve SPECIFICATIONS

35 and 70 lb-in. Non-Spring Return Direct Coupled Actuators ML6161, ML7161, ML6174, ML7174

D-70, D-140, D-210, and D-280 Series Electric Non-Spring Return Actuators

M9300 Series Electric Non-Spring Return Actuators

VA9208-Bxx-x Series On/Off Electric Spring Return Valve Actuators

Versatile and Powerful

AMB24-3(-S) On/Off-Floating Point Control, Non-Spring Return, Direct Coupled, 24 V

OpenAir Electric Damper Actuator GDE/GLB Series Non-spring Return Rotary 24 Vac 3-position Control

3-Way Linked Globe Valve Assemblies with Linear Series Actuators

VBN2, VBN3 Control Ball Valves With Threaded Connections

NFB24, NFB24-S, NFX24, NFX24-S On/Off, Spring Return, 24 V

SAV Electronic Valve Actuator

VBF2, VBF3 Control Ball Valves With Flanged Connections

Z2 050 Q -J +CQB 24 -SR -L

High Pressure 2-way 2 1/2-6 Globe Valves

FlowCon Energy FIT System

B2 Series Characterized Control Valve, Non-Spring Return Actuator

DuraDrive MF /MS Series Non-spring Return Rotary Electronic Damper Actuators 24 Vac Three-position/Modulating

2012 Valve & Valve Actuator Catalog. For new construction or retrofits, simplify projects with our complete selection.

PRESSURE INDEPENDENT CONTROL VALVES (epiv & PICCV )

OpenAir Electric Damper Actuators GDE/GLB Series Non-spring Return Rotary 24 Vac - Modulating Control 0 to 10 Vdc

MF /MS Series

Electronic Globe Valves

NMB (X) 24-MFT. Proportional Control, Non-Spring Return, Direct Coupled, 24V, Multi-Function Technology

VBN2, VBN3 Control Ball Valves With Threaded Connections

Transcription:

VRN Dynamic Pressure-Regulating Control Valves and Actuators FEATURES PRODUCT DATA APPLICATION The VRN2 two-way dynamic pressure-regulating control valves maintain constant flow of hot or chilled water with glycol solutions up to 50% in closed-loop heating, ventilating, and air conditioning (HVAC Division 23) systems regardless of head pressure fluctuations above the minimum specified pressure drop. These valve assemblies can be used with Honeywell non-spring return or spring return direct coupled actuators (DCA) with minimum torque of 35 lb-in (4 Nm) on valve sizes up to 3 inches (DN80). The built-in differential pressure regulator makes fluid flow through the valve independent of changes in supply pressure, eliminating hunting by the control system, even at low coil flow. The pressure regulator virtually eliminates cavitation in the valve, and decouples the control valve from the effects of piping components such as reducers and elbows. Pressure independent control valves are sized to match design coil flow regardless of coil size. VRN2 valves eliminate the need to balance the system for proper flow, and allow chillers to be operated at design temperature differential for maximum efficiency at every load condition. When used in a system with variable speed pump drives, 3-way valves and coil bypass lines are not required. In new construction, VRN2 valves perform better than reverse return piping designs without the extra materials these systems need. Sizes from 1/2 to 3 in. with internal (female) NPT connections. Controls hot or chilled water with up to 50% glycol. Regulated flow rates available from 1 to 95 gpm. Differential pressure regulator for constant pressure drop across valve seat. Positive pressure, rolling diaphragm regulator design for flow control accuracy of ±5%. Equal percentage flow characteristic using patented flow control ball insert. Multiple maximum flow rates available per valve size. Patented ball seals for low operating torque. Nickel-chrome plated brass or stainless steel trim. Choice of factory-installed actuation using Honeywell N05/S05-series direct coupled actuators: Floating, Modulating (2-10 V), Spring Return Modulating/ Floating. Spring return actuators field-configurable for normally open or normally closed fail-safe position. Removable, manual operating handle to control valve during installation or in an event of power failure. Upstream Test Port for venting or pressure gauge attachment. Three actuator orientations on the valve for cramped spaces. Integral snubber eliminates affect of system pressure fluctuations and entrapped air while improving flow performance. Pressure-independent control requires less flow, enabling use of smaller piping, pumps, and chillers. 62-3115EFS-01

SPECIFICATIONS Valve Type: Dynamic Pressure Regulated Control Valve Body Style: Two-way ball valve, straight-through flow, full port with patented flow control insert. Pipe Size: 1/2 to 3 inches with female NPT pipe fittings. Body Pressure Rating (maximum): 360 psi (2500 kpa) at 250 F (121 C). Controlled Medium: Water or Glycol solutions up to 50%. Not suitable for combustible gases, oil or steam. Medium Temperature Range: -22 to +250 F (-30 to +121 C). Maximum Differential Pressure: See Table 1. Close-off pressure: 100 psid Flow Characteristics Equal Percentage with flow control insert. See Fig. 8. Materials Body: Forged Brass (ASTM B283). Flow Optimizer: laser-milled, glass-reinforced Noryl Trim (ball and stem): Nickel-chrome plated brass, or stainless steel. Stem Seals: EPDM O-ring and Teflon bearings. Ball Seals: Reinforced Teflon seals, with EPDM O-rings. Regulator: Hydrogenated acrylonitrile-butadiene rubber rolling diaphragm in stainless steel housing. Compatible Actuators Minimum Torque Required: 35 lb-in. (4 Nm) up to 3 in. ( DN80). 18 lb-in. (2 Nm) up to 3/4 in. (and 1 in. up to 9 gpm). Non- spring return: ML6161, ML7161, MN6105*, MN7505*. Spring return: MS6105, MS7505*, MS8105; MS6103, MS7503, MS8103 only at 1/2 in. or 3/4 in. (DN15 ~ DN 20). * These actuators available factory-installed. See Table 3. Approvals Standards Actuators: See literature for the given actuator. Valve Model Selection: Pressure Regulated Control Valve Fitting Body/Flow Type Size Max flow rate Trim VR - Dynamic pressure regulated control valve Table 1. VRN Model Selection. Profile Actuator Fail Position Accessories MVN613A0000 N- Female NPT threaded MVN613L0000 2-2 way MVN643A0000 A---1/2 (DN15) B--- 3/4 (DN20) C--- 1 (DN25) D--- 1-1/4 (DN32) E--- 1-1/2 (DN40) F--- 2 (DN50) G--- 2-1/2 (DN65) H--- 3 (DN80) MVN643L0000 MVN713A0000 MVN713L0000 MN6105A1011 MN7505A2001 MS7505A2030 MS8105A1030 Fail in place FSO = Fail Safe Open FSC = Fail Safe Closed FSA = Fail A-AB Open FSB = Fail B-AB Open C1-1 meter 3R xxx.xx - Max flow rate designator P- Plated Brass S - Stainless Steel A - Standard Base VR N 2 A 001.00 P A + MVN613A0000 + + C1 Example part number: VRN2A001.00PA+MVN613A0000+C1 62-3115EFS 01 2

Table 2. Actuator Control Description. Actuator MVN613A0000 MVN613L0000 MVN643A0000 MVN643L0000 MVN713A0000 MVN713L0000 MN6105A1011 MN7505A2001 MS7505A2030 MS8105A1030 Control Floating (90 sec. timing) Fast Acting SPDT (30 sec. timing) Modulating On/Off, Floating Floating, Modulating, On/Off (SPDT) Two-Position (SPST) 3 62-3115EFS 01

G CLEARANCE ABOVE ACTUATOR 3/4 (19) E F D A C B M34967 Fig. 1. Dimensions; see Table 3. Table 3. Valve Dimensions. Model Pipe Size Flow, gpm (m 3 /h) Dimensions in in. (mm) NPT in. S.I. metric Min. Rating VRN2A 1/2 DN15 1.0 (0.23) 7.0 (1.6) 10 (2.3) 5.7 (145) Max. Rating Full Port A B C D E F G 4.56 VRN2B 3/4 DN20 9.0 (2.0) (116) 6.6 (167) VRN2C 1 DN25 5.9 (150) 6.6 1.03 (26) 6.7 (170) 10 (2.3) 20 (4.5) 9.0 9.0 1.6 (41) VRN2D 1 1/4 DN32 30 (6.8) 35 (7.9) 8.4 8.6 VRN2E 1 1/2 DN40 8.2 8.5 3.87 (98) 8.4 (212) 9.4 (237) 2.19 (71) Weight lb. (kg) 0.9 (0.4) 1.5 (0.7) Service Replacement Parts Stem: 5112-34 5112-37 (SS); Regulator: 8615-100 for 1 to 3 gpm; 8615-101 for 4 to 10 gpm Stem: 5112-35 5112-38 (SS); Regulator: 8615-102 35 (7.9) 50 (11.4) 10.0 10.1 2.1 VRN2F 2 DN50 25 (5.7) 75 (17.0) 9.9 10.0 (53) (251) (253) VRN2G 2 1/2 DN65 85 (19.3) 95 (21.6) 10.8 (274) VRN2H 3 DN80 11.2 (284) 10.8 (274) 11.2 (284) 10.4 (262) 3.6 (1.6) Stem: 5112-36 5112-39 (SS); Regulator: 8615-031 62-3115EFS 01 4

MVN Actuator SPECIFICATIONS Actuator Type: Valve Rotational Stroke: 90 ±3. Fail Safe Mode: Non-spring return, Fail in place Torque: 27 lb-in. (3 Nm). External Auxiliary Switches Available: No Supply Voltage: 24 Vac +20%, -15%, 24 Vdc Power Consumption: 5 VA- Modulating, 1.5 VA - Floating, 6 VA - Fast Acting SPDT Environmental Rating: NEMA2 APPLICATION MVN 3Nm (27 lb-in.) Control Valve Actuator is used with the VRN2 Dynamic pressure regulated control valves to control hot and chilled water with glycol solutions up to 50% in heating, ventilating, and air conditioning (HVAC) systems to provide two-position or modulating functions. FEATURES Non-spring Return Floating and modulating Space saving, click-on installation no tool required Extendable position indicator for easy commissioning Available with or without cable Compatible with control ball valves from 1/2 to 1-1/4 inches. Actuator can be mounted on the valve in any of four positions. Frequency: 50 Hz; 60 Hz Mounting: Click-on installation no tool required Noise Rating at 1m (Maximum): 35 db(a) max at 1 m [50 db (A) for MVN643]. Materials: Plenum rated plastic housing Operating Humidity Range (% RH): 5 to 95% RH, noncondensing Ambient Temperature Range: -4 F to 131 F (-20 C to 55 C) Storage Temperature Range: -40 F to 176 F (-40 C to 80 C) Weight: 0.6 lb. (0.27 kg) Dimensions: See Fig. 1 and Table 3 Timing: 90 sec. (+/-10%) for MVN613 and MVN713; 30 sec. (+/-10%) for MVN643 Electrical Connections: Field wiring 18 to 20 AWG to screw terminals, located under the removable access cover. Humidity Ratings: 5% to 95% RH noncondensing. Design Life (at Rated Voltage): 60,000 cycles; 1 cycle = 0 90 0 G Cable Specification: 18 AWG, Plenum Rated, 300 V, 10 A, 3 ft. length from end of access cover. Environmental Protection Ratings: IP40. CLEARANCE ABOVE ACTUATOR 3/4 (19) Approvals: UL/cUL UL60730 E B MVN WITH 2-WAY BALL VALVE M34969 Fig. 2. Dimensions; see Table 3 on page 4. 5 62-3115EFS 01

Table 4. Actuators and Accessories Actuator Description Accessory MVN613A0000 MVN613L0000 MVN643A0000 MVN643L0000 MVN713A0000 Floating control ball valve actuator Floating control ball valve actuator Fast acting SPDT contol ball valve actuator C1-1 meter Fast acting SPDT contol ball valve actuator cable Modulating control ball valve actuator MVN713L0000 Modulating control ball valve actuator To order actuator with accessories order actuator part number + accessory. For example: MVN613A0000 + C1 62-3115EFS 01 6

Non-Spring Return Direct Coupled Actuator Maximum Noise Rating, Driving (dba @ 1m): 35 Rotation to Open: By switch Rotational Stroke Adjustment: Dual Integral Adj. Stops (3 degree increments) Compatible Damper Shafts: 1/4 to 1/2 in. square or 3/8 to 5/8 in. round (6 to 13 mm square or 8 to 16 mm round) Shaft Adapter Type: U-bolt clamp Supply Voltage: 24 Vac +20%, -15%, 24 Vdc Power Consumption: 5 VA Materials: Plenum rated plastic housing Ingress Protection Rating: IP54 APPLICATION This non-spring return direct-coupled damper actuator provides modulating and floating/2-position control for: air dampers, air handlers, ventilation flaps, louvers, and reliable control for air damper applications with up to 10 sq. ft./ 44lb.-in. (5 Nm) and 20 sq. ft./88 lb.-in. (10 Nm) (seal-less damper blades; air friction-dependent). FEATURES: Declutch for manual adjustment Adjustable mechanical end limits Access cover includes enclosed screw terminal strip (22 to 14 AWG) for electrical connections Models available with 3 foot 18 AWG color-coded cable Mountable in any orientation Function selection switch for selecting modulating or floating/2-position control Operating Humidity Range (% RH): 5 to 95% RH, noncondensing Ambient Temperature Range: -5 F to +140 F (-20 C to +60 C) Storage Temperature Range: -22 F to +176 F (-30 C to +80 C) Weight: 1 lb (0.45 kg) Includes: Mounting bracket, screws, shaft adapter, water-tight strain-relief cable fittings Comments: Integral 1/2 in. NPSM conduit connection. Approvals: CE: 89/336/ECC, 73/23/EEC C-Tick: N314 Underwriters Laboratories, Inc.: UL873, Plenum Rated Canadian Underwriters Laboratories, Inc.: cul C22.2 No. 24-93 1-5/8 (41) SPECIFICATIONS Actuator Type: Damper; Valve Rotational Stroke: 95 ±3 degrees Fail Safe Mode: Non-spring return Torque: 44 lb-in. (5 Nm) External Auxiliary Switches Available: Yes, SSW2-1M 5-9/32 (134) 3-11/32 (85) 4-1/4 (108) Environmental Rating: NEMA2 Frequency: 50 Hz; 60 Hz Manual operation: Declutch mechanism Mounting: Direct coupled 2-7/16 (62) 2-19/32 (66) M23103A Fig. 3. Non-spring return direct coupled actuator dimensions in inches (mm). 7 62-3115EFS 01

Spring Return Direct Coupled Actuator Frequency: 50 Hz; 60 Hz Mounting: Direct Coupled Maximum Noise Rating, Holding (dba @ 1m): 20 (no audible noise) Maximum Noise Rating, Driving (dba @ 1m): 50 Rotation to Open: By switch Rotational Stroke Adjustment: Mechanically limited 5 degree increments Compatible Damper Shafts: 1/4 to 1/2 in. square or 3/8 to 5/8 in. round (6 to 13 mm square or 9 to 16 mm round) Shaft Adapter Type: Self-centering clamping Materials: Plenum rated plastic housing Supply Voltage: 24 Vac +20%, -15%, 24 Vdc APPLICATION MS4105, MS7405, MS7505, and MS8105 Spring Return Direct Coupled Actuators (DCA) are used within heating, ventilating, and air-conditioning (HVAC) systems. They can drive a variety of quarter-turn, final control elements requiring spring return fail-safe operation. FEATURES Brushless DC submotor with electronic stall protection on all models Self-centering shaft adaptor (shaft coupling) for wide range of shaft sizes Access cover includes enclosed screw terminal strip (22 to 14 AWG) for electrical connections. Models available with 3 foot 18 AWG color-coded cable Durable plastic housing with built-in mechanical end limits Spring return direction field selectable Shaft position indicator and scale UL (cul) listed and CE compliant All models are plenum rated per UL873 SPECIFICATIONS Actuator Type: Damper; Valve Rotational Stroke: 95 ±3 degrees Power Consumption: 5 VA Operating Humidity Range (% RH): 5 to 95% RH, noncondensing Ambient Temperature Range: -40 F to +149 F (-40 C to +65 C) for two-position actuators only Storage Temperature Range: -40 F to +150 F (-40 C to +65 C) Weight: 3.5 lb. (1.6 kg) Includes: Mounting bracket, self-centering shaft adapter Approvals: CE: EMC 2004/108/EC; Certification Low Voltage Directive 2006/95/EC; IEC 60730-1 and Part 2-14 C-Tick: N314 Underwriters Laboratories, Inc.: UL873 Canadian Underwriters Laboratories, Inc.: cul C22.2 No. 24-93 1-9/16 (40) 3-55/64 (98) 1-15/16 (49) 1-1/16 (27) 4-9/16 (116) 1-1/8 (29) 5-27/32 (148) 6-61/64 (177) 3-5/32 (80) 2-27/64 (61) 47/64 (19) Fail Safe Mode: Spring Return Torque: 44 lb-in. (5 Nm) Spring Return Torque: 44 lb-in. (5 Nm) Spring Return Direction: By orientation 2-1/64 (55) M27712A External Auxiliary Switches Available: No Environmental Rating: NEMA2 Fig. 4. Spring return direct coupled actuator dimensions in inches (mm). 62-3115EFS 01 8

HANDLE (REMOVABLE) FOR MANUALLY ROTATING SHAFT 1 SCREWS (2) 1 STEM ASSEMBLY COVER 1 STEM ASSEMBLY 1 BOLT 1 M29518 Fig. 5. Vertical valve installation. 85 85 SCREWS (2) 1 VALVE STEM COUPLER ANTI-ROTATION BRACKET 1 BOLT 1 ANTI-ROTATION BRACKET 2 MOUNTING PLATE 1 Fig. 6. Acceptable valve angle from vertical. M29519A STEM RETAINER PLATE WING NUT 1 VALVE BODY 1 2 INCLUDED IN REPLACEMENT KIT (PART NO. 5112-11). THIS PART USED WITH NON-SPRING RETURN ACTUATORS. M29526A Fig. 7. Actuator mounting plate adjustment. 100% 80% 60% FULL PORT BALL FLOW 40% 20% 2-WAY CHARACTERIZED FLOW 0% 0 10 20 30 40 50 60 70 80 90 VALVE STEM STROKE M29551B Fig. 8. Typical flow characteristics. 9 62-3115EFS 01

Table 5. Flow rate and deferential pressure VRN2A Max flow rate 1.00 2.00 3.00 4.00 5.00 6.00 7.00 min/max differential pressure 3.0/35 3.0/35 3.0/35 3.0/35 3.0/35 3.0/35 3.0/35 VRN2B Max flow rate 1.00 2.00 3.00 4.00 5.00 6.00 7.00 8 9 10 min/max differential pressure 3.0/35 3.0/35 3.0/35 3.0/35 3.0/35 3.0/35 3.0/35 6.0/35 6.0/35 6.0/35 VRN2C Max flow rate 1.00 2.00 3.00 4.00 5.00 6.00 7.00 8 9 10 15 20 min/max differential pressure 3.0/35 3.0/35 3.0/35 3.0/35 3.0/35 3.0/35 3.0/35 6.0/35 6.0/35 3.0/50 3.0/50 4.0/50 VRN2D Max flow rate 10 15 20 25 30 35 min/max differential pressure 3.0/50 3.0/50 4.0/50 5.0/50 5.0/50 6.5/58 VRN2E Max flow rate 10 15 20 25 30 35 40 45 50 min/max differential pressure 3.0/50 3.0/50 4.0/50 5.0/50 5.0/50 4.0/58 6.0/58 6.0/58 6.0/58 VRN2F Max flow rate 25 30 35 40 45 50 55 60 65 70 75 80 VRN2G min/max differential pressure 4.0/58 4.0/58 4.0/58 6.0/58 6.0/58 6.0/58 7.0/58 7.0/58 7.0/58 7.0/58 7.0/58 10.0/58 VRN2H Application Notes IMPORTANT Valve sizing is important for correct system operation. Undersized valves do not have sufficient capacity at maximum load. Oversized valves do not have sufficient authority over the load in modulating applications. Proper Use Oversized valves can cause excessive cycling and the seat and ball can be damaged because of the restricted opening. These valves are only for use in cold, warm, and hot water systems. Not suitable for oil, combustible gases, or steam. They are designed for a medium temperature range of from 35 to 250 F, at a maximum pressure of 360 psig VRN valves are to be operated with the appropriate Honeywell direct coupled actuators only. Water should be properly filtered, treated and conditioned according to local conditions and the recommendations of the boiler or chiller manufacturers. The installation of a strainers and filters is recommended. IMPORTANT The presence of excessive iron oxide (red rust) in the system voids the valve warranty. Required Operating Torque Both Honeywell non-spring return MVN and spring return low torque direct coupled actuators can be utilized with the VRN2 valves. VR valves use a patented seat design that reduces the torque needed from the actuator. Table 6. Close-off, Differential Pressure Ratings. Valve Type Valve Size Close-off Pressure Rating (psi) 2 way 1/2 in., 3/4 in. 100 1 in., 1-1/4 in., 1-1/2 in. 100 TYPICAL SPECIFICATIONS Valve Actuator Direct coupled actuator shall accept analog modulating [(0)2-10 Vdc], floating (tri-state), or two-position signal as indicated in the control sequence. Actuators shall be by Honeywell. Actuator shall provide minimum torque required for full valve shutoff position. Wiring terminals shall be provided for installation to control signal and power wiring. Actuator shall be available with housing suitable for outdoor installation. Accessories Identification tags shall be available for all valves. 62-3115EFS 01 10

Part Number Description Table 7. Actuator Accessories and Replacement Parts. MS8105A1030 MS7505A2030 MN7505A2001 MN6105A1011 MVN713A0000 MVN643A0000 MVN613A0000 5112-3R Weather Enclosure Assembly x x x x MVNAAA Replacement Valve Adaptor x x x MVNAAL Replacement Valve Adaptor, Low Profile MVNAC7131 Replacement Cable with Terminal 1m, Modulation (RED,BLACK,WHITE) x MVNAC6131 Replacement Cable with Terminal 1m, Floating(RED,BLACK,WHITE) x x MVNAT3 Replacement Screw type Terminal Block, Pluggable x x x 5112-11 Replacement actuator bracket x x x x 205860 Minimum position Potentiometer x x x x 32006306-001 Resistor Kit (500 ohm); converts 4-20 ma signal to 2-10 Vdc x x Q7002B1009 Universal Interface Modeule x x x x STRN-SCSA Self-centering Shaft Adapter x x 32000085-001 Strain Relief Fitting (10 pack) x x x x AT120A1004 120 to 24 Vac Transformer (20 VA) x x x x x x x AT140A1000 120 to 24 Vac Transformer (40 VA) x x x x x x x STRN-STRNRLF Stain Relief Fitting (10 pack) x x 11 62-3115EFS 01

Automation and Control Solutions Honeywell International Inc. 1985 Douglas Drive North Golden Valley, MN 55422 customer.honeywell.com U.S. Registered Trademark 2013 Honeywell International Inc. 62-3115EFS 01 M.S. 10-13 Printed in United States