Dynamic Valve Type RA-DV Pressure Independent Radiator Valve

Similar documents
Valve bodies type RA-N with integrated presetting

High Capacity Valve Body, Type RA-G

Integrated Presetting Valves for Normal (013G0380) and Small (013G0381) Volume Flows

High capacity valve body, type RA-G

Integrated Valve with Presetting for Manifolds in Two-Pipe Heating Systems

RA-N Valve Bodies with Pressfit Connection and Self-Sealing Tailpiece for Two Pipe Systems

Integrated Presetting Valves - for Normal Volume Flows RA-N and for Small Volume Flows RA-U

Valve bodies with pressfit connection and self-sealing tailpiece. Type RA-N for two pipe systems

Floor heating system, heating circuit with FHV-A in flow.

Mikrotherm F. Manual Radiator Valves With presetting

X-tra Collection for designer radiators and bathroom towel rails

X-tra Collection for designer radiators and bathroom towel rails

Integrated valves Series 3

Horizontal Distribution Units - HDU Multi-port

V2000FS FS type TRV Body FINELY PRESETTABLE RADIATOR VALVE WITH FLUSH POSITION

The valves can be controlled electronically by thermal actuators or act as self-acting units by means of remote temperature adjusters.

Regutec F. Return Lockshield Radiator lockshield

Combined automatic balancing valve AB-PM valve DN 15-25, PN 16

Manual presetting valves LENO MSV-BD

RTL. Floor Heating Controller Return temperature limiter with and without presetting

V2880, Therafix Design Thera Design Edition - H-Block with TRV Insert WITH HIGH QUALITY SURFACE FOR DESIGN RADIATORS

Combined automatic balancing valve AB-PM valve DN 10-32, PN 16

TDU.3 floor distribution unit SK

Automatic balancing valves ASV-PV DN (3rd gen.)

V5000, V5010 Kombi-3-plus BALANCING AND SHUTOFF VALVES

V Verafix Design Thera Design Edition - Lockshield Valve WITH HIGH QUALITY SURFACE FOR DESIGN RADIATORS

FHF Floor Heating Manifold

Manual presetting valve MSV-C

V2000UB UBG type TRV Body RADIATOR VALVE WITH UNLIMITED CARTRIDGE

V2000BB BB type TRV Body RADIATOR VALVE WITH BROADBAND CARTRIDGE

V2000Kx KV type TRV Body RADIATOR VALVE WITH KV-SPECIALIZED CARTRIDGE

V2000Kx KV type TRV Body

Manual Presetting Valves LENO MSV-B

Differential pressure controller with flow limitation and with integrated control valve (PN 16) AHPBM-F flow mounting, fixed setting

SSM Floor Heating Manifold

Data sheet Pressure independent control valve with integrated flow limiter AVQM (PN 16) - return and flow mounting

Combi valves, PN 25. for rooms, zones, ventilation and air-conditioning systems

Lockshield valves with Pressfit connection Type RLV with isulation and regulation

TRIM, TRIM A, RADITRIM A, TRIM K, STK, TA Loop

FHV control valves are flexible to use, easily installed and are available in two versions:

Flow controller (PN 25) AVQ - return and flow mounting

Fan-coil valves Series

Technical information Thermostatic radiator valves

Please refer to our catalogue for details of the full product range

Flow controller (PN 25) AVQ - return and flow mounting

VPI45.. VPI45..Q. Combi valves, PN 25. Building Technologies. VPI45..Q with pressure test points ACVATIX

AVQMT. AVQT controller can be combined with AVT or STM thermostatic actuators.

V5032. Kombi-2-plus Manual double regulating balancing valve. Product specification sheet

Flow-compensated temperature controller AVTQ DN 15

Flow controller with integrated control valve (PN 16) AVQM - return and flow mounting

Thermostatically operated cooling water valves Type AVTA

Thermostatic actuator RAVI - for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16)

Technote. Frese OPTIMA - Pressure independent control & balancing valve. Application. Features. Benefits.

VPI45..Q with pressure test points. Combi valves, PN 25

Thermostatic valve Type AVTA

HERZ 7217 V. Integral Fixed Orifice Control Valve HERZ 7217 V. Data sheet 7217 V, Issue Size in mm. STRÖMAX Fig No DN L Lm Rp H SW kv kvs

ACVATIX MiniCombiValves (MCV)

HERZ-Motorised flow controler

Technote. Frese OPTIMA Compact DN10-DN50 - pressure independent balancing & control valve. Application. Features. Benefits.

VPI45..Q with pressure test points. Combi valves, PN 25

Combi valves PN 16 with flanged connections

MANIFOLDS AND DISTRIBUTION EQUIPMENT

4-way Distribution Valve

ChangeOver6 and NovoCon ChangeOver6 - Motorized 6-port Ball Valves

Dynacon. Floor Heating Manifolds Floor heating manifold with automatic flow control

Sales information Wave 3,5 Products Product hierarchy

Valves, controls + systems Valves and controls for solar installations Regusol-180

ACVATIX MiniCombiValves (MCV)

Pre-Fabricated Flushing Bypass Assembly for Plant Applications Hero Plant DN15-150

V5003F Kombi-VX PRE-SETTABLE FLOW CONTROL VALVE

Differential pressure controller (PN 16, 25, 40) AFP(-9) / VFG 2(1) return and flow mounting, adjustable setting

Your Personal Catalog Temperature Controllers All our know-how - is now yours

SELF-CLEANING FILTER

RADIATOR VALVE ACCESSORIES

Flow controller with integrated control valve (PN 16) AHQM return and flow mounting

Pressure independent balancing and control valve

2-Port and 3-Port Zone Valves PN 16

2-Port and 3-Port Zone Valves PN 16

Flow controller (PN 16, 25, 40) AFQ / VFQ 2(1) - return and flow mounting

Features PNEUMAT IC VALVES. Pneumatic valves Vip - Pneumatic coaxial valve GENERAL FEATURES CONTROL MEDIA OPERATING MEDIA

Thermostatic radiator valves with presetting

Valencia Radiator Valve Range

Pressure operated water valve Type WVFX and WVS

Data sheet. Thermostatically operated cooling water valves Type FJVA. January 2000 DKACV.PD.500.B B0033

SonoSensor 30 Ultrasonic flow sensor

Pressure independent balancing and control valve AB-QM DN

Combi valves, PN 25. for rooms, zones, ventilation and air-conditioning systems

CALEFFI. FLOWCAL Automatic flow balancing valve with polymer cartridge. 121 series 01141/11 NA. Function

TECHNICAL CATALOGUE DISTRIBUTION MANIFOLDS

Cocon QTZ Pressure independent control valve

Distributor for Floor Heating Systems

Overview of types. Characterised control valves, 3-way, with internal thread For closed cold and warm water systems

k VS DN (mm) Connections ( C) (m 3 /h)

Thermostatic valve Type AVTA

Description Under a clean up process in the TRV business, it has been decided that following Code numbers are going to be cancelled.

Thermostatically controllable valves art. VD/VS/VCR/VCD/VCS xxxx

80% Max working pressure: Max working temperature: 70 C. Flow-meter regulation range: Flow meter-regulation range: ± 10%

2-Port Seat Valves with Flange, PN 25

INDUSTRIAL VALVES BRASS BALL VALVES PLUS WIDE SOLUTIONS ACCORDINGLY TO EVERY KIND OF APPLICATION OPTIMIZED DIMENSIONS & PERFORMANCES THREAD UP TO 4

dynacon floor heating manifold with automatic flow control

Transcription:

Dynamic Valve Type RA-DV Pressure Independent Radiator Valve Application RA-DV straight version RA-DV angle version RA-DV angle Right & Left RA-DV UK (Axial) RA-DV is a series of pressure independent radiator valves, designed for use in -pipe heating systems together with all types of thermostatic sensors with Danfoss RA coupling. RA-DV dynamic valves are fitted with a flow limiting device for presetting of the maximum water flow. The valves are available with maximum water flow of 5-135 l/h. RA-DV has a built-in pressure regulator, which keeps the differential pressure at a constant level of 0.1 bar, thus maintaining the set flow. RA-DV is supplied with a protective cap, which can be used for manual regulation during the construction phase. The protective cap must not be used as manual shut off device. A special manual shut off device (code no. 013G500) should be used. To be able to distinguish between other valve bodies of the Danfoss RA series the RA-DV protective cap and presetting ring are green. RA-DV valve bodies are manufactured from brass with a nickel plating. The gland seal pressure pin is chrominium steel and works in a lifetime lubricated O-ring. The complete gland seal assembly can be replaced without draining down the system. Should water treatment be used it is essential that the manufacturer s dosing instructions are strictly observed. Formulations containing mineral oil should be avoided. In order to avoid deposition and corrosion the composition of the hot water must be in accordance with the VDI 035. Quality RA-DV Dynamic Valves with sensors RAW, RAE and RAS-C are certified according to the European standard EN 15. All Danfoss radiator thermostats are manufactured in factories, assessed and certified by BSI (British Standard Institution) against ISO 9000 and ISO 14001. VDGWJ41 Danfoss 05/016 1

Principles Application example 1 Application example Ordering Valve Type Size Connection Inlet Outlet Design RA-DV DN10 Rp 3/8 R 3/8 Angle 013G100 RA-DV DN10 Rp 3/8 R 3/8 Straight 013G00 RA-DV DN10 Rp 3/8 R 3/8 UK (Axial) 013G0900 RA-DV DN15 Rp ½ R ½ Angle 013G300 RA-DV DN15 Rp ½ R ½ Straight 013G400 RA-DV DN15 Rp ½ Rp ½ UK (Axial) 013G1000 RA-DV DN0 Rp 3/4 Rp 3/4 Angle 013G500 RA-DV DN0 Rp 3/4 Rp 3/4 Straight 013G600 Accessories Gland seal, 10 pcs. p tool for pump optimization Presetting tool Valve insert with Regulator 5 pieces 013G090 013G855 013G830 013G831 VDGWJ41 Danfoss 05/016

Compression fittings* Tube dimension For valve type For PEX plastic tubing, 10 pcs. For Alupex tubing, 10 pcs. For steel and copper tubing, 10 pcs. 1 x 1.1 mm RA-DV 15 013G4143 1 x mm RA-DV 15 013G414 14 x mm RA-DV 15 013G4144 15 x.5 mm RA-DV 15 013G414 16 x mm RA-DV 15 013G4146 1 x mm RA-DV 15 013G41 14 x mm RA-DV 15 013G414 16 x mm RA-DV 15 013G416 10 mm RA-DV 10 013G4100 1 mm RA-DV 10 013G410 10 mm RA-DV 15 013G4110 1 mm RA-DV 15 013G411 14 mm RA-DV 15 013G4114 15 mm RA-DV 15 013G4115 * For more information on Danfoss compression fittings, please refer to the compression fittings data sheet. Technical Data Max. working pressure 1) Max. differential pressure Min. differential pressure Test pressure Max. working temperature Min. working temperature 10 bar 0.6 bar 0.1 bar 16 bar 95 C Presetting 1 3 4 5 6 N with living sensor & TWA 3) 5 l/h 30 l/h 35 l/h 45 l/h 60 l/h 80 l/h 100 l/h 135 l/h with RA 000 sensor ) 0 l/h 5 l/h 30 l/h 40 l/h 50 l/h 5 l/h 95 l/h 15 l/h with RAW, RAE or RAS-C sensor ) 15 l/h 0 l/h 30 l/h 40 l/h 50 l/h 0 l/h 90 l/h 110 l/h 1) Working pressure = static + differential pressure. The maximum differential pressure specified is the maximum pressure at which the valves give satisfactory regulation. ) At setting N the value is stated according to EN 15, at XP = K i.e. the valve is closed at C higher room temperature. At lower settings the XP value is reduced to 0.5K of the setting value 1. All values are max. flow at 0.1 bar. 3) The value states the max. flow at maximum lift, i.e. at fully open valve at 0.1 bar. C Presetting The presetting values of RA-DV valves can be adjusted easily and accurately without the use of tools (default setting = N). Presetting can be selected in steps from 1 to : Remove protective cap / thermostatic sensor. Find reference mark (R). Turn setting ring until the aquired presetting aligns with the reference mark. At setting N the valve is fully open. This setting can be used as a flushing position, if the system has to be flushed out because of dirt problems. R When the thermostatic sensor has been installed, the presetting is protected against unintended regulation. VDGWJ41 Danfoss 05/016 3

Design 1 3 4 5 6 8 9 10 1. Pressure pin. Gland seal 3. O-ring 4. Setting dial 5. Seal 6. Regulation spring. Valve body 8. Regulator 9. Spring 10. Impulse connection The thermostatic radiator valve consist of a sensor and the valve body RA-DV. Sensor and valve body are ordered separately. The gland seal of the valve can be changed in operation, i.e. with water and pressure on the system. Counter hold with star spanner number 1 and loosen the gland seal with spanner number 10. Materials in contact with water Valve body and other metal parts Valve body surface Flow-limiter O-ring Valve cone Pressure pin and spring Regulator Brass Nickle plated PPS EPDM NBR Chrome steel Brass/EPDM Capacities RA-DV max. flow 160 140 10 100 Presetting N [l/h] 80 60 40 0 5 4 3 1 0 0 10 0 30 40 50 60 P [kpa] 6 Sizing example Required heat 00 W Cooling across radiator 0 C Flow through radiator Q = 00 0 x 1.16 = 30 l/h Min. pressure for constant flow 0.1 bar Valve setting* *Alternatively the setting can be read directly in the table Technical Data. 4 VDGWJ41 Danfoss 05/016

Dimensions RA-DV UK Axial / RA990 sensor Type ISO -1 Arc. flats L 1 L L 3 L 4 L 5 L 6 L DN D d S 1 S RA-DV 10 UK 013G0900 10 Rp 3/8 R 3/8 - - 6 51 61 11 RA-DV 15 UK 013G1000 15 Rp 1/ R 1/ - - 9 58 61 11 30 RA-DV DN0 Straight & Angle valve / RA 990 sensor Type RA-DV 0 angle RA-DV 0 straight ISO -1 Arc. flats L 1 L L 3 L 4 L 5 L 6 L DN D d S 1 S 013G500 0 Rp 3/4 R 3/4 - - 34 6 9 66 11 3 3 013G600 0 Rp 3/4 R 3/4 4 10 - - - - 103 3 3 VDGWJ41 Danfoss 05/016 5

Dimensions L L6 L5 56 L3 L4 81 RA-DV angle valve /+ RA 990 sensor S d L1 L L S1 D RA-DV straight valve / RA 990 sensor Type Note! If RAW, RAE or RAS-C sensors are used instead of sensors from the RA000 series the L measurement Danfoss A/S is extended with 1 mm. Heating Solutions Haarupvaenget 11 8600 Silkeborg Denmark Phone: +45 488 8000 Fax: +45 488 8100 e-mail: heating.solutions@danfoss.com www.heating.danfoss.com ISO -1 DN D d Arc. flats L 1 L L 3 L 4 L 5 L 6 L S 1 S RA-DV 10 right 013G100 10 Rp 3/8 R 3/8 - - 5 5 103 RA-DV 10 left 013G1800 10 Rp 3/8 R 3/8 - - 5 5 103 RA-DV 15 right 013G1900 15 Rp 1/ R 1/ - - 30 58 33 5 103 30 RA-DV 15 left 013G000 15 Rp 1/ R 1/ - - 30 58 33 5 103 30 RA-DV 10 angle 013G100 10 Rp 3/8 R 3/8 - - 6 51 64 114 RA-DV 10 straight 013G00 10 Rp 3/8 R 3/8 58 84 - - - - 10 RA-DV 15 angle 013G300 15 Rp 1/ R 1/ - - 9 5 6 66 11 30 RA-DV 15 straight 013G400 15 Rp 1/ R 1/ 65 94 - - - - 10 30 6 VDGWJ41 Danfoss 05/016