PMV WS/WM Series UltraSwitch

Similar documents
PMV WS/WM Series UltraSwitch

Accord WS/WM Series UltraSwitch

Accord DS/DM Series UltraSwitch Switch box

Accord DS/DM Series UltraSwitch Switch box

Automax DS/DM Series UltraSwitch Switch box

USER INSTRUCTIONS. Automax WS/WM Ultraswitch Switchbox. Installation Operation Maintenance FCD AXENIM /16

flowserve.com Flowserve Solenoid Valves Namur, Remote and Banjo Mounted Designs for Precision Control

PMV. P5 Pneumatic Positioner. Product Information

D30 Compact Digital Positioner

USER INSTRUCTIONS. PMV PS/PM Ultraswitch Switchbox. Installation Operation Maintenance FCD PMENIM /13

Product Specification

USER INSTRUCTIONS. Accord PS/PM Ultraswitch Switchbox. Installation Operation Maintenance FCD ACENIM /14

Product Specification

Installation Operation Maintenance

Installation Operation Maintenance

Product Specification

Figure 1 Figure 2 Double Acting Actuator Spring Return Actuator

Kämmer Series Low Flow Valve

Kämmer Series Split Body Valves

Kämmer Series Low Flow Valves

Valve Position Monitors

Installation Operation Maintenance

TECHNICAL BULLETIN. NAF Setball SF Ball Sector Valves. Experience In Motion. flowserve.com. NAF Setball FCD NFENTB A4 02/16

CRANE Limit Switches. CCR Series. CXA Series. CCA Series

USER INSTRUCTIONS. Automax XCL/XML UltraSwitch. Installation Operation Maintenance. Switchbox. Experience In Motion FCD AXENIM A4-09/16

TECHNICAL BULLETIN. NAF Trunnball DL Ball Valves. Experience in Motion FCD NFENTB A4 09/14

flowserve.com Limitorque LRP Limitorque Rack & Pinion Pneumatic Actuator

Logix 3800 Digital Positioner

Desuperheater FCD VLENTB /11. Experience In Motion

Kämmer Multi-Z Severe Service Valves

Mounting: The following instructions apply to rotary actuators only. Linear applications require special mounting and coupling (consult factory).

TECHNICAL BULLETIN. NAF Duball DL Ball Valves. Experience in Motion FCD NFENTB A4 12/14

APS & APIS ATEX AIRPOWER SWITCH BOXES FEATURES DESCRIPTION

NAF Duball DL Pocket Ball Valves TECHNICAL BULLETIN FCD NFENTB A4 11/17

Valve Position Monitors

flowserve.com Kämmer Multi-Z Kämmer Multi-Z Severe Service Valves

Vogt Valves The Connection Bulletin for Y Pattern Globe & Check Valves Class 1690 & Class 2680 CB 18

Logix 3800 Digital Positioner

WORCESTER CONTROLS F519/529/819/829. Full Bore Fire Safe Flanged Ball Valves

Vogt Valves The Connection Bulletin for Forged Steel Globe Valves for Water-Free Chlorine Service Class 300, 600 & 800 CB 07

Limitorque Actuation Systems PT Series Worm Gear Operator

Limitorque Actuation Systems B320 Series. Rugged and dependable bevel gear operators for manual or motorized valve control applications

General purpose / hazardous area

Know-how makes the difference. Limit Switches

SERIES 5A AND 5B VALVE STATUS MONITOR THE HIGH PERFORMANCE COMPANY BRAY SERIES 70 ELECTRIC ACTUATORS

Installation Instructions

LIMIT SWITCHES & POSITION INDICATION

USER INSTRUCTIONS. Limitorque TM V Series. Installation Operation Maintenance. Experience In Motion FCD LMENIM AQ 02/15

Limitorque HBC Series Worm Gear Operators

Limitorque Accutronic MX/WTR Performance and Dimensions. Limitorque Actuation Systems

TECHNICAL BULLETIN. Logix 510si Series Digital Positioner. Experience In Motion FCD LGENTB /13

Rotary Switches & Positioners

USER INSTRUCTIONS. Installation Operation Maintenance. NAF Setball SF Ball Sector Valves. Experience In Motion FCD NFENIM A4 09/16

SERIES 5A AND 5B VALVE STATUS MONITOR THE HIGH PERFORMANCE COMPANY BRAY SERIES 70 ELECTRIC ACTUATORS

TECHNICAL BULLETIN. Audco Ball Valve. Reduced Bore Fire safe Flanged Ball Valves 51/52 Series. Experience In Motion

Installation Operation Maintenance

V200 Series Positioners

Limitorque. HBC Series Worm gear operators proven in the most demanding situations

TECHNICAL BULLETIN. Logix 505si Series Digital Positioner. Experience In Motion FCD LGENTB /13

Automax SuperNova Series. Pneumatic Rack & Pinion Actuators

Valtek XL Series High Performance Positioner. for Control Valves

flowserve.com Durco PlugSeal Valve ASME Class 600 Plug Valves Serving the Worldwide Desalination Industry Experience In Motion

V200 Series Positioners

Quartz. Save Space with Low Profile Design

LIMIT SWITCH BOX MODEL - APL

Solenoid Block Kit for Series 90 Modular Accessory System Installation, Operation and Maintenance Instructions

Plug Valve Solutions for the Upstream Exploration and Production Pipelines Production manifolds, test manifolds and other dirty services

V200 Series Positioners

USER INSTRUCTIONS. NAF Trunnball DL Ball Valves. Installation Operation Maintenance. Experience In Motion FCD NFENIM A4 01/15

Installation Instructions

CONTROLS INC. Position Indicators. Valve Positioners

Installation, Operating & Maintenance Instructions. Norbro J-Switch FM 00707

Experience In Motion. Flowserve Control Valve Products North American Quick Response Centers

VALVE ACCESSORIES & CONTROLS V200 POSITIONER A POSITIONER THAT OFFERS IT ALL IN ONE COMPACT, SIMPLE, HOUSING

Edward. Equiwedge Forged Gate Valvee. Experience In Motion

MARPAC K SERIES. Full Bore Fire Safe Flanged Ball Valves

ALS SERIES VALVE MONITOR ATEX. Exd

Installation Instructions

Valtek Valdisk 150. Valtek Valdisk 150. Control Valves. Flowserve Corporation, Valtek Control Products, Tel. USA

ISC Series Innovative Standard Cartridge Seals

Installation Instructions

AP ATEX AIRPOWER POSITIONERS AP2000 FEATURES AP1000 & AP1200 FEATURES OPTIONS OPTIONS

Features. Flexibility

Installation Instructions

Installation Instructions

Worcester Controls Directional Ball Valves

Valtek Tek-Check. Check Valves

S-17 CATALOG. Forged Steel Strainers

Series 72 Electri-SAFE On/Off Operation Including CLC Option Installation, Operation and Maintenance Instructions

2N1 TM PROXSENSOR ACCESSORIES VALVE STATUS MONITOR SERIES 52 2 INDUCTIVE PROXIMITY SENSORS AC, DC & INTRINSICALLY SAFE VERSIONS

Valtek Spring Cylinder Linear Actuators

ISO-9001:2000 certified Aplus Finetek Sensor, Inc.

INTERNATIONAL METAL ENGINEERING

Actuator size P2 P3 P4 P5 Diaphragm area cm Thrust max. dan Stroke mm

USER INSTRUCTIONS. Spring Diaphragm Rotary Actuators. Installation Operation Maintenance. Experience In Motion FCD VLAIM /12

SPECIFICATIONS. Limitorque MX. Selection Data. Experience In Motion. Performance and Dimensions for MX Series 05 through 150 Electric Actuators

SERIES 54 PROXIMITY SENSORS

Type 4746 Electric or Pneumatic Limit Switch

Installation Instructions

Installation Instructions

Transcription:

PMV WS/WM Series UltraSwitch TM Switch box

Compact Reliable Great Value WS/WM Series Ultraswitch Description The WS/WM Series UltraSwitch provides cost efficient, accurate and reliable position signaling. The compact enclosure is offered in aluminum or corrosion resistant engineered resin and is provided with multiple switch options. A variety of covers and indicators are available in aluminum and resin. The range covers domed and flat indicators as well as covers without indicator for a lower profile. The WS/WM is designed to be directly and easily mounted onto actuators for both rotary and linear indication. It may also be used as a junction box for direct connection of solenoid valves. Minimum two open terminals are always provided. Its compact housing has multiple mounting possibilities, up to four conduit entries and pre-wired switches to enable easy installation. It is designed to meet IP66/67 and NEMA Type 4X standards and is offered both for Intrinsically Safe and Non-Incendive hazardous locations. Features and Benefits Switches available in a wide range of options (See Technical Data page - switch options) Tool-free Quick-Set cams Easily accessed pre-wired terminal strip Minimum two open terminals are provided Housing of aluminum or corrosion resistant engineered resin Conduit entries (2x) ½ NPT or (2x) M20x1.5mm Temperature range -40 C to +80 C -40 F to +180 F

Hazardous Locations Approvals Typical applications / industries suitable for the WS/WM-Series UltraSwitch are: Chemical & Petrochemical Food & Beverage Municipal & Wastewater Pharmaceutical Power Hazardous locations approvals and communication Intrinsically safe: Approvals for ATEX and ccsaus hazardous locations, Intrinsically Safe and Non-Incendive. AS-Interface (AS-i) The WS/WM-series can be equipped with optional AS-i communication capabilities. This technology offers a very simple, flexible and cost efficient network system. Mounting options NAMUR or optional low profile mounting Standard NAMUR EN15714 mounting kits are available for standard NAMUR shafts. In applications where space is limited, the optional S shaft reduces the height 15% providing a significantly lower mounting profile. Available for 80x30 and 130x30 actuator top patterns with an actuator shaft height of 20, 30 or 50mm. NAMUR actuator mounting kit Low profile mounting kit KL01 & KL02

Cover and Indicator Options Aluminum or engineered resin housing with multiple cover options Aluminum or Resin cover Dome indicator Aluminum or Resin cover Blank without indicator Aluminum or Resin cover Flat indicator Polycarbonate transparent cover Dome indicator Polycarbonate transparent cover Flat indicator Aluminum housing (Cover materials: Aluminum and Polycarbonate) Resin housing (Cover materials: Resin and Polycarbonate)

Technical Data Switch Options Data/Materials Code Cert. Switch Option Manufacturer Load Capacity Data M1 A SPDT Mechanical Honeywell MicroSwitch MG A, B SPDT Gold Mechanical Honeywell MicroSwitch F1 IN5129 IFM 10-36VDC 15A @ 125/250 VAC; 0,5A @ 125 VDC; 0,25A @ 250VDC; 5A @ 120VAC 1A @ 125 VAC; 50 ma @ 24 VDC F3 IF5250 IFM 10-36VDC NC PNP, 150mA, 3-wire NC Ingress protection Weight maximum IEC 529 IP 66/67, NEMA Type 4X 0.7kg / 1.55 lbs F5 IF6001 IFM 18-32VDC, NO PNP, 150mA@50 C F6 IF6034 IFM 10-36VDC, NO PNP, 150mA, Stainless Steel F7 IN0074 IFM 20-250 AC/DC NO, 350mA/100mA F8 IN0081 IFM 20-250 AC/DC NO, 350mA/100mA w/ LED FJ IN5263 IFM IN-2002-FRKG/PH RT P4 A, B, C SPST Proximity Aleph 0.35A @ 140 VAC; 0.25A @ 200VDC (50 W Max.) P5 A, B, C SPDT Proximity Hamlin 0.25A @ 120 VAC; 0.25A @ 28 VDC (3 W Max.) PE A, B, C SPDT Sabre Proximity Flowserve 1A @ 120 VAC; 1A @ 24 VDC PP C SPDT Phazer Proximity Flowserve 3A @ 120 VAC; 2A @ 24 VDC PT A, B, C SPST BRS Proximity Flowserve 3A @ 120 VAC; 0.5 @ 24 VDC N8 A Solid State Proximity PF NJ2 V3 N NAMUR NC Sensor; 8 VDC NP A Solid State Proximity PF SJ3.5-N NAMUR Sensor Output; 5-25 VDC Supply NQ A Solid State Proximity PF NJ4-12GK-N NAMUR NC Sensor; 8 VDC Part Material Housings Powder epoxy painted Aluminum or PA6/PA66 engineered resin, 25 30% fiberglass filled Covers Powder epoxy painted Aluminum or PA6/PA66 engineered resin, 25 30% fiberglass filled or Transparent Polycarbonate Shaft Stainless Steel SS EN 2346 / AISI 303 Cams/Splines Nylon Terminal Block Nylon Internal Brackets Nylon, Aluminum or Stainless Steel All External Fasteners Stainless Steel All Internal Fasteners Stainless Steel All Molded in Anodized Aluminum Fasteners Indicators Polycarbonate or PA66 Label Polyester Plug Nylon NR Solid State Proximity PF NJ4-12GM40-E1 PNP Sinking; 200 ma max. Current; 10-60 VDC NS Solid State Proximity PF NJ4-12GM40-E2 NPN Sourcing; 200 ma max. Current; 10-60 VDC NT Solid State Proximity PF NJ4-12GK40-E2 NPN Sourcing; 200 ma max. Current; 10-60 VDC N9 Solid State Proximity PF NBB3-V3-Z4 NPN Sourcing; 100 ma max. Current; 5-60 VDC NW A Solid State Proximity PF SJ3.5-SN NAMUR NC Sensor; 8 VDC Code A B C Certificate ATEX II 1GD Ex ia IIC T4/T5/T6 ATEX II 1GD Ex ia IIB T4/T5/T6 ccsaus IS ccsaus NI More switch options available

WS/WM-Series Ultraswitch Switchbox Nomenclature A = B = C = D = E = F = G = H = I = J = Brand sticker P PMV Shaft type N Namur shaft, EN 15714 S Short shaft, low profile style T For NAF Turnex D Double D 1/4 Inch Flats Body style WS General Purpose/I.S. Enclosure / 1/2 NPT Conduit entries WM General Purpose/I.S. Enclosure / M20x1.5mm Conduit entries Number of conduit entries 2 2 conduit entries 4 4 conduit entries (2 according to C + entries opposite side with different type of threading) Body material A Aluminum R Engineered resin Cover material A Aluminum R Engineered resin (J=14 only) P Polycarbonate Cover (clear) Indicator 1 No indicator 2 Flat Indicator H Black / Yellow UltraDome (Black Close/Yellow Open) U UltraDome (Red Close/Green Open) Number of switch elements 0 No switches (empty housing) 1 1 Switch 2 2 Switches Switch type - See section with switch options Certificate 14 General Purpose 15 ATEX Ex ia 28 ccsaus Ni 29 ccsaus IS Ordering code example A B C C D E F G H I I J J P N W S 2 A R U 2 P P 2 8 A = brand, NAMUR shaft, 1/2 NPT Housing with 2 conduits, Aluminum body, Resin cover, standard UltraDome, 2 proximity switches PP, ccsaus certificate (2 open terminals) Mounting kits A B C Mounting kit NAMUR p/n A = Bolt pattern length (mm) B = Bracket height (mm) C = Height (mm) Mounting kit p/n Actuator shaft height (mm) Bolt pattern 80/30 (mm) Bolt pattern 130/30 (mm) C = Height (mm) 30 mm 23648 80 45 105 23649 80 55 115 23650 130 55 115 c KL01 20/30 yes yes 80/90 KL02 50 yes yes 110

Dimensions WS/WM (mm/inch) WS body enclosure USE CABLE GLANDS OR OTHERS SUITABLE TO ENSURE THE DEGREE OF PROTECTION OF THE ENCLOSURE (IP66/67, TYPE 4X) 50/1.968" 42/1.654" 103/4.055" 50ISO 5211 F05 35.4/1.394" M6(4X) 35.4/1.394" WM body enclosure USE CABLE GLANDS OR OTHERS SUITABLE TO ENSURE THE DEGREE OF PROTECTION OF THE ENCLOSURE (IP66/67, TYPE 4X) CABLE ENTRIES 1/2"-14 NPT CABLE ENTRIES M20 X 1.5 27.5/1.083" 4.5/.177" 35/1.378" 1/2"-14 NPT M5(2X) 30/1.181" 80/3.150" CLEARENCE=82/3.228" 76/3" M20X1.5 ALUMINUM OR RESIN COVER WITH FLAT INDICATOR CLEARANCE=112 106 CLEARANCE=65 59 120/4.724" CLEARANCE=66 59,5 CLEARANCE=150 99 ALUMINUM OR RESIN COVER WITH ULTRADOME INDICATOR FLAT ALUMINUM OR RESIN COVER WITHOUT INDICATOR FLAT TRANSPARENT PC COVER WITH FLAT INDICATOR TRANSPARENT PC COVER WITH ULTRADOME INDICATOR 4/.157" 0.5/.020" 4/.157" 23.5/.925" 12,2 5.9/.231" 6.35/.250" FLATS LOW PROFILE SHAFT NAMUR SHAFT EN15714 DOUBLE "D" SHAFT 8/.315" 4/.157" 18,6/.734" TURNEX SHAFT FOR NAF

PMV Automation AB Korta Gatan 9 SE-171 54 Solna SWEDEN Tel: +46 (0) 8 555 106 00 Fax: +46 (0) 8 555 106 01 E-mail: infopmv@flowserve.com Germany Flowserve Flow Control GmbH Rudolf-Plank Strasse 2 D-76275 Ettlingen GERMANY Tel: +49 (0) 7243 103 0 Fax: +49 (0) 7243 103 222 E-mail: argus@flowserve.com UK Flowserve Flow Control Burrell Road, Haywards Heath West Sussex RH16 1TL Phone: +44(0)1444 314400 E-mail: pmvuksales@flowserve.com FCD PMENBR0019-03 A4 09/16 To find your local Flowserve representative: For more information about Flowserve Corporation, visit flowserve.com Hazardous Locations ATEX II 1 GD Ex ia IIC T4/T5/T6 ATEX II 1 GD Ex ia IIB T4/T5/T6 ccsaus Cl. I, Div. 1 Grp. A,B,C,D; Cl. II Div. 1 Grp. F,G; Cl. III ccsaus Cl. I, Div. 2, Grp. A,B,C,D; Cl. II, Div. 2, Grp F,G; Cl. III Italy Flowserve Spa Via Prealpi, 30 20032 Cormano (Milano) ITALYsTel: +39 (0) 2 663 251 Fax: +39 (0) 2 615 18 63 E-mail: infoitaly@flowserve.com USA, Mexico PMV-USA 14219 Westfair West Drive Houston, TX 77041, USA Tel: +1 281 671 9209 Fax: +1 281 671 9268 E-mail: pmvsales@flowserve.com flowserve Corporation has established industry leadership in the design and manufacture of its products. When properly selected, this flowserve product is designed to perform its intended function safely during its useful life. However, the purchaser or user of flowserve products should be aware that flowserve products might be used in numerous applications under a wide variety of industrial service conditions. Although flowserve can (and often does) provide general guidelines, it cannot provide specific data and warnings for all possible applications. The purchaser/user must therefore assume the ultimate responsibility for the proper sizing and selection, installation, operation, and maintenance of flowserve products. The purchaser/user should read and understand the Installation and Maintenance (I & M) instructions included with the product, and train its employees and contractors in the safe use of flowserve products in connection with the specific application. While the information and specifications contained in this literature are believed to be accurate, they are supplied for informative purposes onlyand should not be considered certified or as a guarantee of satisfactory results by reliance thereon. Nothing contained herein is to be construedas a warranty or guarantee, express or implied, regarding any matter with respect to this product. Because flowserve is continually improving andupgrading its product design, the specifications, dimensions and information contained herein are subject to change without notice. Should any question arise concerning these provisions, the purchaser/user should contact flowserve Corporation at any one of its worldwide operations or offices. 2015 Flowserve Corporation, Irving, Texas, USA. Flowserve and PMV are registered trademarks of Flowserve Corporation. Asia Pacific Headquarters Flowserve Pte Ltd. No. 12 Tuas Avenue 20 REPUBLIC OF SINGAPORE 638824 Tel: +65 (0) 687 98900 Fax: +65 (0) 686 24940 E-mail: fcdasiaprocess@flowserve.com The Netherlands Flowserve Flow Control Benelux Rechtzaad 17 4703 RC Roosendaal THE NETHERLANDS Tel: +31 (0) 30 6771946 Fax: +27 (0) 30 6772471 E-mail: fcbinfo@flowserve.com flowserve.com