Door Closer Arms Used with regular arm mounting (pull side) and top jamb mounting (push side) Non-Hold Open arm standard on the DC3200 (Hold-Open) 597F52 Heavy-Duty Mounted on pull side Optional on DC3200 closer, specify closer x A10 x 188F41 x 509F49 Non-Hold Open arm combines regular arm with Hold Open arm combines regular hold open arm with Non-Hold Open arm standard on the DC3210 *Not allowed by code on fire doors..7
Door Closer Arms Top Jamb Used with top jamb mounting (push side); for reveals up to 3-3/4" (95 mm) Non-Hold Open arm standard on the DC3220 689F02 Heavy-Duty Optional on DC3210 closers Non-hold open arm, specify closer x A3 Hold open arm, specify closer x A2*. Hold-open range 85 to 110 689F01 689F03 689F04 Heavy-Duty Reversible Backstop (mounted on push side) Field-reversible steel lug restricts degree of opening to protect door, wall and hardware Requires both backcheck valves on closer Shipped standard as left hand. Handing can be reversed in the field Optional on DC3210 closers Non-hold open arm, specify closer x A4. Door stop range 85 to 110 Hold open arm, specify closer x A5*. Door stop/hold open range 85 to 110.8 *Not allowed by code on fire doors.
Quick Codes Mounting DC3200 Closers Multi-sized; full adjustability from size 1-6 Top Jamb DC3200 DC3210 DC3220 Sex nuts and bolts (SNBs) (1-3/4" minimum thickness) Delayed action Full cover Miscellaneous Options M54 M71 Arm Regular non-hold open Hold open A1* Heavy-duty parallel with hold open A2* Heavy-duty parallel non-hold open A3 Heavy-duty backstop non-hold open A4 Heavy-duty backstop with hold open A5* Corrosion protection Heavy-duty parallel arm flush transom bracket (499F30) used with A2, A3, A4, A5 arms Parallel arm flush transom bracket (parallel or A1) Parallel arm offset bracket Mortise arm bracket (for regular arm mounting) Angle support bracket M75 M79 M82 M83 M84 M85 Heavy-duty regular non-hold open A10 Extreme temperature fluid * Hold Open arms cannot be used on fire doors. Handing Drop Plates - order by number (formerly M80) Hand Closer Series Drop Plate Right Hand/Left Hand Reverse RH DC3210 (parallel) 597F58 Left Hand/Right Hand Reverse LH DC3220 (top jamb) 188F65 Finish USP Primed for Painting 600 N/A Dark Oxidized Satin Bronze - equivalent 613E SBL Silver Aluminum Painted 689 LBL Dark Bronze Painted 690 DBL Light Bronze Painted 691 FBL Black Painted 693 GBL Satin Brass Painted 696 Paint (cans) Silver Aluminum Dark Bronze Light Bronze Satin Brass 597F94 597F95 597F96 597F97 Door Thickness Door Thickness 1-3/4" (44mm) 2" (51mm) D200 2-1/4" (57mm) D214.13
Arm Options DC6000 Used with regular arm (pull side) and top jamb (push side) mounting Non-hold open arm standard on the DC6200 and DC6400 closers Hold open arm optional, specify closer x A1* 691F72 Deep Reveal Arm ( 3-3/8" (86mm) - 7-1/4" (184mm)) Accommodates top jamb mounting for reveals up to 7-1/4" (184mm), depending on door and frame conditions Optional on DC6220 and DC6420 closers Non-hold open, specify closer x A6 Hold open, specify closer x A8* Non-Hold Open Hold Open 691F72 691F74 597F52 (Non-Hold Open Only) Heavy-Duty Mounted on pull side Not available in plated finishes Optional on DC6200 and DC6400 closers, specify closer x A10 x 188F41 x 509F49 Non-hold open arm combines regular arm with parallel arm mounting bracket Hold open arm combines regular hold-open arm with Non-hold open arm standard order DC6210 or DC6410 series Hold open arm optional, specify closer x A1* finish when ordering arms. *Not allowed by code on fire doors. DC6000.8 Copyright 2004-2015 Corbin Russwin, Inc., an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the express written permission of Corbin Russwin, Inc. is prohibited. 45052-3/15
How To Order DC6000 Ordering Examples Stock Quantity Finish Misc. Options 50 DC6210 689 M54 Where to find ordering information and quick codes Page 17 Arm Page 18 Finish Page 18 Handing Page 18 Door Thickness Page 18 Miscellaneous Options Page 19 Job Specific Quantity Finish Hand Thickness Options 50 DC6413 626 RH D138 M71-M73 Split Finish Quantity Cover Finish Arm Hand Misc. Options 10 DC6210 626 689 RH M54 Note: Door closer warranty becomes void if it is installed on the exterior side of a door in the exterior wall of a building It is strongly recommended, and it is required on fire door assemblies, that doors having a door closer be hung on ball-bearing or anti-friction hinges or pivots Failure to use the correct type and size fasteners may void factory warranty Fasteners for fire/smoke door assemblies must conform to NFPA 80. In some applications additional fasteners may be mandated by NFPA 80 that are not shipped with Corbin Russwin's standard product, such as sleeve-units/sex nuts or through-bolts and grommet nuts Consult factory if door weight exceeds 250lbs. Mounting Non-sized Size 1 Size 2 Size 3 Size 4 Size 5 Size 6 Regular arm DC6200 DC6200 Closers Multi-sized; full adjustability from size 1-6 Parallel arm DC6210 Top jamb DC6220 Track (Pull Side) DC6230 Track (Push Side) DC6240 Regular arm DC6401 DC6402 DC6403 DC6404 DC6405 DC6406 DC6400 Closers Sized; 1 2-size adjustability Parallel arm DC6411 DC6412 DC6413 DC6414 DC6415 DC6416 Top jamb DC6421 DC6422 DC6423 DC6424 DC6425 DC6426 Track (Pull Side) DC6433 DC6434 DC6435 DC6436 Track (Push Side) DC6443 DC6444 DC6445 DC6446 45052-3/15 DC6000.17 Copyright 2004-2015 Corbin Russwin, Inc., an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the express written permission of Corbin Russwin, Inc. is prohibited.