Data sheet Connection line M12-RJ45 4-pole D-coded AWG m

Similar documents
Data sheet Connection line M12-RJ45 4-pole D-coded AWG m

Data sheet. Connection line M12 4-pole D-coded 1.0 m. Illustrations P/N 142M1D11010 EAN Product specification. Page 1/

Data sheet Connection line M12 plug straight - RJ45 plug straight 8-pole, X-coded 5.0 m

Data sheet. Connection cable M12 jack straight - free line end 8-pole, X-coded 0.5 m. Illustrations P/N 142M2X20005 EAN

Data sheet E-DAT Industry patch cord V6 IP67 - RJ m

Data sheet E-DAT Industry RJ45 field plug black Cat.6 Class E A

Data sheet. E-DAT Industry RJ45 field plug PROFINET. Illustrations P/N PI EAN Product specification. Page 1/

Data sheet Patch cord Cat.6 A AWG m gray

Data sheet C6 A RJ45 field plug pro

Data sheet Patch cord Cat.6 A AWG m black

Data sheet E-DAT C6 A 24 port patch panel 1RU LSA modular

Data sheet. E-DAT modul REG 1 port IP20 light gray. Illustrations P/N E EAN Product specification. Page 1/

Data sheet E-DAT Industry terminal rail TS35 + RJ45 coupler insert Cat.6 Class E A

Data sheet E-DAT modul Cat.6 A 8(8) jack, T568A

Data sheet E-DAT modul 24x8(8) 1RU patch panel Cat.6 A, stainless steel

Data sheet E-DAT subway 9 port GB3 pearl white

Data sheet. E-DAT modul Cat.6A 8(8) jack, T568A. Illustrations P/N I EAN Product specification. Page 1/

Data sheet E-DAT Industry RJ45 coupler insert Cat.6 Class E

Data sheet. E-DAT modul Cat.6A 8(8) jack, T568A. Illustrations P/N I EAN Product specification. Page 1/

Data sheet E-DAT modul 24x8(8) 1RU patch panel Cat.6A, light gray

Data sheet E-DAT modul 1 port UPk Cat.6 A, pure white

Data sheet C6 A modul 24 port 180 M 1RU stainless steel

Data sheet C6 A modul 6 port 180 M GB3 pearl white

Technical Data Sheet Shielded (CY) PVC Control Cable

Technical Data Sheet Shielded (CY) PVC Control Cable

Technical Data Sheet Unshielded (YY) PVC Control Cable

ÖLFLEX CLASSIC 115 CY

600/1000 V. 5. Flame Retardancy VDE , DIN EN , IEC

ÖLFLEX CLASSIC 110 CY

Technical data sheet LÜTZE SUPERFLEX PLUS (C) PUR FEEDBACK Encoder cables for Siemens and other systems For highest requirements in drive technology

PRODUCT INFORMATION. UNITRONIC LiYCY. Benefits Overall shield minimises electrical interference Versatile application possibilities

Technical Data Sheet Shielded (CY) PVC Control Cable

Identification Type SU+M(C)P SE(4G1,5+(2 0,75)+(2 AWG22))UL 1KV OR. Part-No

Technical data sheet LÜTZE SUPERFLEX PLUS M (C) PUR SERVO 0.6/1 kv Supply line for Bosch Rexroth and other systems For highest requirements

Technical Data Sheet Unshielded (YY) PVC Control Cable

Part Number: 10GX F/UTP CMR PATCH CORDS 10GX F/UTP CMR Patch Cords

PRODUCT INFORMATION. UNITRONIC SPIRAL LiF2Y11Y. Info New: the unscreened spiral cables with small cross section High restoring forces PUR outer sheath

PRODUCT INFORMATION. UNITRONIC LiYCY. Benefits Overall braid minimises electrical interference Multifunctional application possibilities

PRODUCT INFORMATION ÖLFLEX HEAT 125 C MC. Info Improved characteristics in the event of a fire GL - Germanischer Lloyd approved

SAC-4P-M12MS/ 5,0-PUR SH

SPECIAL CABLES TEMPERATURE MEASUREMENT HARNESSING CABLES FOR RAILWAY TECHNOLOGY. den-belitsky / Fotolia

6000 Series Ethernet Buccaneer

Operating voltage up to 5 kvdc Operating current up to 4,5 A 2-6 high voltage contacts Quick and easy assembling Protection class IP68 acc.

VDE tested single cores according to EN (H05Z-K & H07Z-K) for more demanding requirements

Cables for Railway Technology

Part Number: CAT6+ UTP CMR PRE-TERM 6 CAT6+ UTP CMR Pre-Term 6

Technical attributes

FISCHER FREEDOM TM SERIES

ÖLFLEX CLASSIC 110 H Info Benefits

ÖLFLEX CLASSIC 135 CH -halogen-free control cable, HFFR, flexible and screened for various applications, U 0 /U: 300/500V

INFORMATION. Hybrid cables. Description

General characteristics and technical data Series MCS

SAC-5P-3,0-PUR/M12FS SH

K CHAPTER FREEDOM TM SERIES EASY MATING EASY CLEANING EASY INTEGRATION FISCHER KEY FEATURES

Data sheet CFBUS.PVC PVC - e-chain - Bus cable for medium load requirements (class 4.3.2): shielded, oil-resistant as well as flame-retardant.

Ethernet Buccaneer BUCCANEER DATA. bulgin

ÖLFLEX CLASSIC 130 H - halogen-free control cable, HFFR and flexible for various applications, U 0 /U: 300/500V

Data sheet chainflex CF886

VDE-registered oil-resistant PVC control cable with black outer sheath for a wide range of applications

Data sheet chainflex CF210.UL

Data sheet chainflex CF8821

14 HH EAC/CTP CE RoHS-II conform

Operating voltage up to 5 kvdc Operating current up to 4,5 A 2-6 High voltage contacts Quick and easy assembling Protection class IP68 acc.

Data sheet chainflex CF881

CFBUS CFBUS.PVC.040 CFBUS.PUR.040 CFBUS.040 CF CAT5 CFBUS.041 CFBUS.044

Data sheet chainflex CF6

USA: UL-listed (MTW), Canada: CSA (TEW), Europe: <HAR> H07V-K (depending on cross s.), tin-coated strands

CAN-Bus cable. CAN-Bus cable Can-Bus / Field-Bus cable for medium to maximum load requirements. chainflex cable. Overview. igus e-chainsystems

Ethernet Buccaneer IP68 BUCCANEER FOR DATA BUCCANEER DATA

Coupling ring, screw thread provides secure cable coupling. Shielded Cat 5e coupler maintains screening. Retaining Nut

Data sheet chainflex CF140.UL

Data sheet chainflex CF886

Data sheet chainflex CF270.UL.D

PRODUCT INFORMATION. ÖLFLEX HEAT 180 SiF. Info Flexible fine-wire copper conductor

Data sheet chainflex CF240

ÖLFLEX VFD 2XL - screened VFD cable for fixed installation or occasional flexing with UL TC-ER.

INDUSTRIAL SOLUTIONS MARINE CATALOGUE INNOVATIVE CABLE SOLUTIONS MEETING INTERNATIONAL STANDARDS

Comtran Cable. Commercial Premise & Specialty Datacom Products. Cat 5e - Cat 6A. LSZH & Industrial Ethernet. Indoor/Outdoor & Outside Plant

CF270.UL.D.

PRODUCT INFORMATION H07V-K

Industrial Ethernet Cables

Datasheet. BL/SL 5.08 series BLF 5.08/02/180 SN OR BX

SPECIAL CABLES TEMPERATURE MEASUREMENT HARNESSING BLUELINE - CABLES FOR SHIPBUILDING.

PRODUCT INFORMATION. ÖLFLEX HEAT 180 SiF

Insulation Colours: Orange (Standard) Natural Natural. Sheath Colours: Orange (Standard) Orange (Standard) Bedding: Black

Cables for cable carriers and reels SYSTEMS IN MOTION

Data sheet chainflex CFSOFT1

Bus system Profibus Ethernet (CAT 5e / GigE / PoE) ASinterface Part. No. CF CF CF & CF mm

Data sheet chainflex CF340

IEEE 1580 TYPE T/N CABLE

DNV-GL HH CE RoHS-II conform

Data sheet chainflex CF10

us cables New! chainflex guarantee club Guaranteed lifetime Selection table page 154 CFBUS.PVC PVC 12,5-5/

Data sheet chainflex CF310.UL

DIN Valve Connectors - VAD 1A/1B Series

SABIX Ultra. Standards: EN EN Cat C or D IEC (halogen-free)

PRODUCT INFORMATION MULTI-STANDARD SC 2.1. U.I. Lapp GmbH

www. h itech controls.com (800) I (303) Click or Call for a Quotel Photo: HELUKABEL Robotic Cables C HELUKABEL

0.6/1KV FLAME RETARDANT ARMORED & SHEATHED CABLE PRODUCT CONSTRUCTION 1. CONDUCTOR

SPECIAL CABLES TEMPERATURE MEASUREMENT HARNESSING CABLES FOR CLEAN ROOM TECHNOLOGY. industrieblick / Fotolia

Transcription:

Page 1/6 Illustrations Dimensional drawing Wiring See enlarged drawings at the end of document Product specification shielded M12 to RJ45 Ethernet connection line Cat.5, 4-pole, D-coded (IEC 61076-2-101) M12 connector, straight to RJ45 connector connectors over molded stranded wires 2x2xAWG22/7 overall shield tinned copper braid pin assignment per Profinet green cable, PUR standard variants: 1.0 m, 2.0 m, 3.0 m, 5.0 m, 10.0 m other cable lenghts on request

Page 2/6 General Data Fields of application Industrial Ethernet Design Ethernet-Connection line Shielding shielded Transmission technology Copper Cable Type S/FTQ Number of twisting elements 4 Twisting element single core Wiring Profinet Color coding fiber/ wire(s) yellow, orange, white, blue Color green Dimensions Dimension - Interface 1 (L x W x H) 45.50 x 13.30 x 13.60 mm Dimension - Interface 1 (L x W x H) 1.791 x 0.524 x 0.535 in. Dimension - Interface 2 (L x W x H) 52.30 x 15.00 x 15.00 mm Dimension - Interface 2 (L x W x H) 2.059 x 0.591 x 0.591 in. Cable length (m) 10.00 m Cable length (ft) 3.28 ft Labeling option identification label carrier Transmission characteristics Category (ISO) 5 Connections/interfaces Connector technology interface 1 RJ45 plug Connector technology interface 2 M12-plug Coding interface 2 D-coded Number of positions/contacts interface 1 8P/4C Number of positions/contacts interface 2 4 Termination data, stranded wire (min. - max.) Conductor cross section, stranded wire AWG 22/7 Conductor cross section, stranded wire 0.355 mm² Conductor diameter, stranded wire (bare copper) 0.762 mm Conductor diameter, stranded wire (bare copper) 0.03 in. acceleration 3 m/s²

Page 3/6 Electrical characteristics Current carrying capacity max. 1 A Through resistance max. 5 mohm Insulation resistance min. 10^8 MOhm Mechanical characteristics Position/mounting of latch - standard installation position Bending radius without load top Bending radius without load 3.819 in. Bending cycle Shielding braid coverage 97.5 mm 3 mio 85 % Materials and material properties Material - Conductor Cu (copper) Material - Cable jacket PUR Material - Inner cable jacket FRNC, with an aluminized film Material - Plug housing interface 1 PVC (polyvinyl chloride) Material - Body interface 2 Plastics Material - Contact interface 1 CuSn (tin bronze) Material - Contact interface 2 CuZn (brass) Material - Contact finish interface 1 Au (gold) Material - Contact finish interface 2 Au (gold) Material - Contact carriers interface 2 Plastics Material - Union nut interface 2 CuZn (brass) Material - Union nut finish interface 2 Ni (nickel) Material - Shield interface 1 CuSn (tin bronze) Material - Main shield Cu (copper) braid Material - Main shield finish Sn (tin) Flame retardancy Halogen free Oil resistance UV-resistance

Page 4/6 Environmental conditions Temperature (min. - max.) Temperature - Storage C -50-70 C Temperature - Storage F -58-158 F Temperature - Operating C -30-70 C Temperature - Operating F -22-158 F Temperature - Installation C -20-60 C Temperature - Installation F -4-140 F Particulate ingress interface 1 IP2X Liquid ingress/immersion interface 1 IPX0 Particulate ingress interface 2 IP6X when plugged in Liquid ingress/immersion interface 2 IPX7 when plugged in Pollution degree interface 1 1 Pollution degree interface 2 3 Approvals RoHS compliant The product meets the following standards Generic cabling systems General requirements ISO/IEC 11801-1 DIN EN 50173-1 Profinet Multi-element metallic cables used in analogue and digital communication and control Prüfung der vertikalen Flammenausbreitung an einer Ader, einer isolierten Leitung oder einem Kabel Measurement of smoke density of cables burning DIN EN 50288-4-1 DIN EN 60332-1-2 DIN EN 61034 Classifications ETIM 5.0 EC002599 ETIM 6.0 EC002599

Page 5/6 Packing details Type of packaging 1 pc(s) / plastic bag Packaging unit - Weight (gram) 117.00 g Packaging unit - Weight (pound) 0.26 lb

Page 6/6 Illustrations Dimensional drawing Wiring Powered by TCPDF (www.tcpdf.org)