I.L. 29C121A WARNING 1. INTRODUCTION. Maximum Freq. Maximum Dielectric Voltage Current Withstand (V) (A) Voltage (V)

Similar documents
a WARNING Allen-Bradley Parts K-Frame Circuit Breaker Instruction Leaflet for Alarm Switch and Alarm /Auxiliary Switch Combination Bul.

Q and M-Frame Circuit Breakers Instruciton Leaflet for Alarm Switch and Auxiliary Switch Combinaiton

I.L. 29C184A File WARNING

Cutler-Hammer I.L. 29C160G WARNING NOTICE 1-0 INTRODUCTION. General Information

Cutler-Hammer. Installation Instructions for Undervoltage Release Mechanism (Handle Reset) with LED for E 2 L and E 2 LM Mining Circuit Breakers

Installation Instructions for JDB, JD, HJD, JDC, JW HJW, JWC Circuit Breakers and Molded Case Switches

Cutler-Hammer. Installation Instructions for the ND OPTIM 550 PowerNet and/or Zone Interlock Accessories (ICK 550N, ZGK550N, ZGPK550N) I.L.

Installation Instructions for KPS and KPH Circuit Breakers and Molded Case Switches

Installation Instructions for the 14" Walking Beam Interlock for L-Frame and MDL-Frame Series C Circuit Breakers and Molded Case Switches

! WARNING I.L D WARNING GENERAL INFORMATION

Q and M-Frame Circuit Breaker Instruction Leaflet for Installation and Operation for Thermal Magnetic Trip Units

Installation Instructions for Type SM Safety Handle Mechanism for L-Frame Series C Circuit Breakers and Molded Case Switches

Cutler-Hammer. Installation Instructions for the Digitrip OPTIM Pole Trip Unit Installation and Operation with L-Frame Series C Circuit Breakers

A WARNING. Installation Instructions for KD, HKD, KDC, CKD, CHKD Circuit Breakers I.L. 29C092C

Installation Instructions for TMQV Circuit Breakers and Molded Case Switches

Installation Instructions for R-Frame Circuit Breakers and Molded Case Switches

N-frame Circuit Breaker

Installation Instructions for NW, HNW, and NWC Circuit Breakers and N-frame Series C Molded Case Switches

Two-way cable interlock kit for Magnum drawout circuit breakers

Digitrip Retrofit System for ITE K-3000, K-3000 S, K-4000 and K-4000 S Breakers

Digitrip Retrofit System for General Electric AKR/AKRU-6D/7D-30S Series Breakers

O & M Manual for the EATON Generator Ready Loadcenter

Digitrip RMS and Digitrip OPTIM Trip Units Used with R-Frame Circuit Breakers

Digitrip Retrofit System for Allis-Chalmers LA-600 F Electrically Operated Fused Breakers

Digitrip Retrofit System for Siemens-Allis RLX-1600 Breakers

Digitrip Retrofit System for the Federal Pioneer 25-H(L)-2, 30-H(L)-2, 30-H(L)-3, and 30-3 Breakers

Digitrip Retrofit System for Allis-Chalmers G-25 Breakers

Installation Instructions for Series C F-Frame 310+ Electronic Circuit Breaker Types FDE, HFDE, FDCE

Digitrip Retrofit System for BBC LKD 8 Breakers

' '!' D Model, 70 to 250 Amperes. W Model, 63 to 250 Amperes. www. ElectricalPartManuals. com

Installation Instructions for Interlocking Trip Indicator with Remote Reset for Magnum Low Voltage Circuit Breakers

Two-way cable interlock kit for Magnum fixed circuit breakers

Table Types LD, HLD and LDC Thermal-Magnetic Circuit Breakers with Interchangeable Trip Units

Removal/installation instructions for Series NRX (IZMX) drawout levering (racking) mechanism

www. ElectricalPartManuals. com Digitrip Retrofit System for Allis-Chalmers LA-4000 F Fused Breakers IL 33-A1K-1 WARNING

CM52 Network Protector with Arc Flash Reduction Module

TVSS Installation for RLCM/CHGENLC, RLCU, and CHGEN ATSs

Instructions for A200, A210, A250 size 6, two- or three-pole non-reversing or reversing motor controllers

L-Frame LD F. Circuit Breaker/ Frame Ampere Rating. Trip Unit Rating/ Plug Ampere Rating LD T5 7 W

Digitrip Retrofit System for the ITE LG-3000 (Frameless) Circuit Breaker

Table Line and Load Terminals. Terminal Body Material. Wire Type. Aluminum Copper Aluminum. English English English.

CCP2-FLR1-21_ flange-rod operating mechanism

Instructions for using Functional Test Kit on Digitrip 520 and 1150 family of Power Circuit Breaker Trip Units and Series G and FD MCCB Trip Units

Instruction Booklet IB E. Contents

Reprogramming guide. Power Defense ICCB. Instructional Leaflet IL EN WARNING WARNING. Instructions apply to:

2.3. Molded Case Circuit Breakers. Contents. Internal Accessories. Series C. Product Overview. Description

Installation Instructions for R-Frame G-Series (RG) 310+ Trip Unit

design prefix 50 Hanover Road, Florham Park, New Jersey USA (ASCO), for service call (ASCO)

Advanced Test Equipment Rentals ATEC (2832)

ProTrip Conversion Kits. For GE Types AK-15, AK-25, and AKU- 25 Low-Voltage Power Circuit Breakers INTRODUCTION. DEH Installation Instructions

3-way multi-family drawout cable interlock kit - type 32 - RF

Owner s Manual. Series 165 Automatic Transfer Switches rated 100 and 200 amps, single phase, 240 V ac for automatic 2 wire start generators

Installation Instructions for Series C F-Frame 310+ Electronic Circuit Breaker Types FDE, HFDE, FDCE

GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector

Bulletin 1494V Variable Depth Flange-Mounted Disconnect Switches. Bulletin 1494F Fixed-Depth Flange-Mounted Disconnect Switches

www. ElectricalPartManuals. com Digitrip Retrofit System for BBC LKD 8 Breakers IL 33-LK8-2

CONTENTS. This Product is Certified by CANADIAN STANDARDS ASSOCIATION and Bears the Mark:

Instruction Bulletin Dual Sub-Feed Circuit Breaker and Adapter Kit Installation onto an NQ Panelboard Class 1640

www. ElectricalPartManuals. com Digitrip Retrofit System for the Westinghouse DA-50 IL 33-DAC-2 WARNING

Installation and removal instructions for Series NRX RF fixed breaker three-way Type 32 cable interlock kit

Mipco Connections for Refrigerated Containers. No One Does It Like Mipco. The Mipco. Advantage. Reliability. Safety. Easy Installation & Service

DANGER. Instruction Bulletin WARNING. Shunt Trip Kit for Manual DS/DSL Circuit Breakers POWER ZONE III Low Voltage Switchgear Class 6035 INTRODUCTION

Lighthouse Power Pedestals,

Interrupting Capacity (Symmetrical Amperes) Volts ac (50/60 Hz) Y/ ,000 25,000. Frame Only E2L3600F

VA9208-Bxx-x Series On/Off Electric Spring Return Valve Actuators

Q-Frame Main Circuit Breaker (225 A Maximum) and Adapter Kit Installation onto an NQ Panelboard Class 1640

Florham Park, NJ USA Call (ASCO) for sales or service

section-page Table 1. Transfer switching device ratings. Conditional short circuit current

Florham Park, NJ USA Call (ASCO) for sales or service

Instruction Bulletin NF Panelboard Dual Sub-Feed Circuit Breaker Adapter Kit Installation onto an NF Panelboard Class 1670

WARNING. Instructions for Combination Bypass Isolation and Transfer Switches Amps I.L A FILE APPLICATION SAFETY PRACTICES

OSS - TN, TBN Type. Information to Order. Features. External View ATS(60~600A) OSS P- A B C D. Rated Current. D Operating Voltage

30C30 definite purpose contactor

Installation Manual. E-design A Transfer Switches A

Digitrip Retrofit System for the General Electric AKR 6D/7D-30/50 and AKRT 6D/7D-50 Series Breakers

3ATS & 3NTS J-design 600 A 3ADTS & 3NDTS A Transfer Switches. Installation Manual. Installation A DANGER. Table of Contents WARNING

M9206-Bxx-2S Series On/Off Electric Spring Return Actuators

Installation Instructions Electric Heaters 5 20 kw

100-Ampere Busway. Effective November 2005 New Information. Elbow, Busway and Cable Tap Box. Technical Data TD E

Modular Metering - Trip Unit for >1200A Mains DEH41187 Application Guide

TMC 91H is now TMC 60 C Series

Installation Instructions

Cutler-Hammer. January 2001

QO and QOU Miniature Circuit Breakers QO Circuit Breaker Accessories

Elegance Electrician s Installation Guide

RotoTract Remote Racking Operating Manual

Instruction Booklet for the Installation, Operation and Maintenance of Type 5-15 kv VCP-WG Vacuum Circuit Breaker 4000A MiniMod

Eaton Digitrip RMS and Digitrip OPTIM Trip Units with Types DSII and DSLII Low Voltage Power Circuit Breakers

w w w. h d o n l i n e s h o p. d e LAYBACK LICENSE PLATE AND TURN SIGNAL RELOCATION KIT INSTALLATION GENERAL -J03892 REV Kit Number

Installation Instructions For Motor Control Center (MCC) Units

ibusway for Data Center

Electrically Held to Mechanically Latched Contactor

Parts Manual. Transfer Switch. OTPCB (Spec A) 150/225/260 Amps. English Original Instructions (Issue 4)

Parts Manual. Transfer Switch. OTPCC (Spec A) 300/400/600 Amps. English Original Instructions (Issue 4)

E.S.P. Embedded Sensing Probes for Motor Brushes

READ AND FOLLOW ALL SAFETY INSTRUCTIONS! SAVE THESE INSTRUCTIONS AND DELIVER TO OWNER AFTER INSTALLATION.

Installation and Operation Manual. Value Switch Package (VSP and VSP+)

M9208-Bxx-3 Series On/Off Electric Spring Return Actuators

Cutler-Hammer. Molded Case Circuit Breakers Amperes January J-Frame

CP-8301-xxx Series. Application. Features. Applicable Literature. 1 to 15 Vdc Input Electronic Actuator Drive General Instructions

Transcription:

Installation Instructions for Auxiliary Switch for JDB, JD, HJD, JDC, JW, HJW, JWC Circuit Breakers, Molded Case Switches, and J-Frame Motor Circuit Protectors I.L. 9C11A! WARNING DO NOT ATTEMPT TO INSTALL OR PERFORM MAIN- TENANCE ON EQUIPMENT WHILE IT IS ENERGIZED. DEATH, SEVERE PERSONAL INJURY, OR SUBSTAN- TIAL PROPERTY DAMAGE CAN RESULT FROM CON TACT WITH ENERGIZED EQUIPMENT. ALWAYS VERI- FY THAT NO VOLTAGE IS PRESENT BEFORE PRO- CEEDING WITH THE TASK, AND ALWAYS FOLLOW GENERALLY ACCEPTED SAFETY PROCEDURES. EATON IS NOT LIABLE FOR THE MISAPPLICATION OR MISINSTALLATION OF ITS PRODUCTS. The user is cautioned to observe all recommendations, warnings, and cautions relating to the safety of personnel and equipment as well as all general and local health and safety laws, codes, and procedures. The recommendations and information contained herein are based on Eaton experience and judgement, but should not be considered to be all-inclusive or covering every application or circumstance which may arise. If any questions arise, contact Eaton for further information or instructions. 1. INTRODUCTION General Information The auxiliary switch (Fig.1-1) indicates circuit breaker contacts status, and is used for remote signaling and system interlocking purposes. The switch consists of one or two single pole double-throw (SPDT) switches assembled to a plug-in module. The plug-in module is mounted in slots in the top of the trip unit; it occupies the accessory cavity in the circuit breaker frame, and is positioned so that the switch actuator arm rests against the molded crossbar. Each SPDT switch has one "a" and one "b" contact. When the molded crossbar is in the contacts-closed position, the "a" contact of each SPDT switch is closed and the "b" contact is open. When the molded cross bar is in the tripped or contacts-open position, the "a" contact is open and the "b" contact is closed. Table 1-1 lists electrical rating data for the auxiliary switch. Table 1-1. Auxiliary Switch Electrical Rating Data 1 3 Maximum Freq. Maximum Dielectric Voltage Current Withstand (V) (A) Voltage (V) 600 50/60 Hz 6 500 15 DC 0.5 50 DC 0.5 Endurance: 6000 electrical operations plus 000 mechanical operations. Pigtail wire size No. 18 AWG (0.8 mm'). 3 Terminal block is listed for use with one or two No. 18 to No. 14 AWG solid or stranded copper wire. Torque is 7 Ib in (0.8 N.m). 4 Noninductive load. Fig. 1-1. Auxiliary Switch Installed in J-Frame Circuit Breaker Depending on the model ordered, connections for the auxiliary switch are in one of four forms. The standard wiring configuration is pigtail leads exiting the rear of the base directly behind the accessory. Optional configurations include a terminal block mounted on the same side of the base as the accessory, leads exiting the side of the base where the accessory is mounted, and leads exiting the rear of the base on the side opposite the accessory. The 18- inch long pigtail leads are color coded for identification; identification labels are provided for pigtail leads and terminal block points. For allowable locations of all accessories, refer to Frame Book 9-10.

Page I.L. 9C11A Auxiliary Switch Plug-in With Pigtail Leads No more than three pigtail leads can be routed through the rear trough in the circuit breaker base. When the walking beam interlock is used with the circuit breaker, the rear trough cannot be used for accessory pigtail leads. This instruction leaflet (IL) gives detailed procedures to install the auxiliary switch.. INSTALLATION Accessory Identification Label Connection Diagram Label (Pigtail Lead Label Shown ) The auxiliary switch can be field-installed in JD, HJD, and JDC circuit breakers under UL File E64983. The auxiliary switch can be field-installed in JW, HJW, and JWC circuit breakers. For sealed circuit breakers, Underwriters Laboratories, Inc. UL489 requires that internal accessories be installed at the factory. The auxiliary switch is listed for factory installation under UL File E7819. Where local codes and standards permit and UL listing is not required, internal accessories can be field installed in JDB sealed circuit breakers. In this case, UL listing becomes invalid and the label should be removed. Before attempting to install the accessory, check that the catalog number is correct and that the rating of the accessory satisfies job requirements. The auxiliary switch, shown in kit form in Fig. -1, can be installed in the right or left accessory mounting cavity of a -, 3-, or 4-pole circuit breaker. An auxiliary switch must be installed in the circuit breaker before the circuit breaker is mounted in an electrical system. To install the auxiliary switch, De the following procedures: A circuit breaker that is mounted in an electrical system must be removed to install the accessory. To ensure correct accessory installation, the circuit breaker must be Placed on a horizontal surface. Wire Marking Labels (Supplied With Double Aux. Switch Only) Fig. -1. Auxiliary Switch Kit! WARNING BEFORE REMOVING A CIRCUIT BREAKER INSTALLED IN AN ELECTRICAL SYSTEM, MAKE SURE THE CIRCUIT BREAKER IS SWITCHED TO THE OFF POSITION AND THERE IS NO VOLTAGE PRESENT WHERE WORK IS TO BE PERFORMED. SPECIAL ATTENTION SHOULD BE PAID TO REVERSE FEED APPLICATIONS TO ENSURE NO VOLTAGE IS PRE- SENT. THE VOLTAGES IN ENERGIZED EQUIPMENT CAN CAUSE DEATH OR SEVERE PERSONAL INJURY. -1. Switch circuit breaker to OFF position. -. Disconnect and remove circuit breaker from installation and terminal connections. For new circuit breaker installation, trip unit must be installed in circuit breaker before attempting to install auxiliary switch. Refer to l.l. 9C600, I.L. 9C601, or l.l. 9C60 for instructions on how to install the trip unit. -3. Remove cover screws and cover.

I.L. 9C11A Page 3 For an auxiliary switch having rear or opposite side exiting pigtail leads, thread leads through center trough in side of case before attempting to insert mounting bracket. Pigtail leads exiting in this manner should be eased through trough as mounting bracket is inserted into trip unit retaining slots. Use center slot for leads exiting side of the circuit breaker. -4. Route wiring to meet installation requirements. (See Fig -). Right-Hand Auxiliary Switch Installed (Pigtail Lead Type Shown) Auxiliary Switch Above Left-Hand Accessory Mounting Cavity Rear Exiting Leads Preferred Terminal Block Fig. -3. Auxiliary Switch Installation Positions spring loaded retaining pin snaps into pin recess. Auxiliary switch operating arm(s) must be between accessory operating projection on molded crossbar and arc extinguisher. For terminal block assemblies, slide terminal block into mounting slot on side of base as plug-in module is being positioned. b. If required, complete routing of leads to opposite-side through rear wiring trough. c. For double auxiliary switch pigtail leads, attach wire marking labels to bundle of three leads for each switch. (Markers designated 1 and are provided.)! CAUTION Side Exiting Leads Fig. -. Accessory Wiring Options! CAUTION Opposite Side Exiting Leads PIGTAIL WIRES SHOULD BE FORMED AND ROUTED TO CLEAR ALL MOVING PARTS WHEN ACCESSORY IS PROPERLY INSTALLED. PIGTAIL LEADS COULD BE DAMAGED IF IN CONTACT WITH MOVING PARTS -5. Insert the auxiliary switch as described in the following steps (Fig. -3): a. Slide auxiliary switch plug-in module into slots until WHEN INSTALLING CIRCUIT BREAKER COVER, MAKE SURE THAT ALL INTERNAL PARTS ARE IN PLACE: SLIDING HANDLE BARRIERS ARE POSITIONED SO THAT THE HANDLE OPENING IS ALIGNED WITH THE HANDLE. PIGTAIL LEADS ARE CLEAR OF COVER. WHEN REMOVED AND REINSTALLED, THREAD- FORMING SCREWS TRY TO REFORM THE THREADS IN THE CIRCUIT BREAKER BASE. CARE SHOULD BE TAKEN EVERY TIME A THREAD-FORMING SCREW IS USED TO ENSURE THAT THE SCREW STARTS IN THE ORIGINAL THREADS. DAMAGED THREADS CAN RESULT IN IMPROPER CIRCUIT BREAKER COVER

Page 4 I.L. 9C11A Screw,.164-3 X 3.13 Inch, Pan Head, Cross -Recessed Screw, No.8 X 1.88 Inch, Pan Head, Cross -Recessed, Fig. -4 Cover Screw Installation Positions Also Used With 4-Pole Circuit Breaker Note: Hatched Lines Show Additional Pole and Screws for 4-Pole Circuit Breaker. Modification Label Accesory Identification Label thread forming screws, as shown in Fig. -4. -7. Remove and discard UL listing label on JDB circuit breakers only. -8. Place accessory labels (supplied with kit) on circuit breaker. (See Fig. -5). Accessory labels show connection diagram for auxiliary switch. Pigtail leads are color coded red, black, and blue. -9. Test auxiliary switch(es). Connect continuity tester or ohmmeter across pigtail leads or terminal block connections. Check continuity as follows: a. Circuit breaker handle OFF a contact(s) - open b contact(s) - closed. b. Circuit breaker handle ON a contact(s)- closed b contact(s)- open. c. Press PUSH-TO-TRIP button a contact(s)- open b contact(s) - closed. d. If auxiliary switch(es) fails test, make sure that auxil iary switch(es) module is properly seated in trip unit slots. If auxiliary switch(es) appears to be correctly installed and the problem persists, contact Eaton. -10. Install circuit breaker. Terminal Block (When Used) Terminal Block Connection Diagram Label (When Used) Pigtail Lead Connection Diagram Label (When Used) Fig. -5. Preferred Mounting Locations for Accessory Nameplate Labels RETENTION. -6. With circuit breaker handle in OFF position and accessory pigtail leads (if used) routed as required, install circuit breaker cover. Secure with pan-head screws followed by Fig. -6. Auxiliary Switch Connection Diagram -11. Connect auxiliary switch as required. (See Fig. -6). Eaton assumes no responsibility for malfunctioning accessories installed by the customer.

I.L. 9C11A Page 5

Page 6 I.L. 9C11A

I.L. 9C11A Page 7

Page 8 I.L. 9C11A Eaton Electrical, Inc. 1000 Cherrington parkway Moon Township, PA 15108-431 USA Tel: 1-800-55-000 www.eatonelectrical.com 015 Eaton corporation All Rights Reserved Style 6631C64H0 Printed in Dominican Republic