MPS AND MPS PR¼ 16 OUTPUT DEMAND CONTROLLER PENTAIR CLEAN AIR SYSTEMS. AVS Danmark ApS Skelvej Hedehusene

Similar documents
200 SERIES THREADED VALVES PENTAIR CLEAN AIR SYSTEMS

On Demand, Differential Pressure Controls

300 SERIES DRESSER NUT VALVES PENTAIR CLEAN AIR SYSTEMS

400 SERIES MANIFOLD MOUNT VALVES PENTAIR CLEAN AIR SYSTEMS

600/700 SERIES FLANGED VALVES PENTAIR CLEAN AIR SYSTEMS

ECONOMISER SERIES E2T USER MANUAL

MECAIR 200 SERIES THREADED VALVES CLEAN AIR SOLUTIONS PRODUCT LEAFLET

5 TANK ¾ VALVE AND 6 TANK 1 VALVE HEADER TANK SOLUTIONS PENTAIR CLEAN AIR SYSTEMS

10 TANK WITH 2 VALVE HEADER TANK SOLUTIONS PENTAIR CLEAN AIR SYSTEMS

MECAIR 300 SERIES DRESSER NUT VALVES CLEAN AIR SOLUTIONS PRODUCT LEAFLET

MECAIR 400 SERIES MANIFOLD MOUNT VALVES CLEAN AIR SOLUTIONS PRODUCT LEAFLET

MECAIR 600/700 SERIES FLANGED VALVES CLEAN AIR SOLUTIONS PRODUCT LEAFLET

THE TOTAL SOLUTION PROVIDER

MECAIR PXA/PEX HAZARDOUS PILOTS CLEAN AIR SOLUTIONS PRODUCT LEAFLET

Installation, Operation and Maintenance Manual. EVC Controller (from February 2007)

RAINTIGHT ENCLOSURE. mecair CSN

mecair 5 TANK ¾ VALVE AND 6 TANK 1 VALVE HEADER TANK SOLUTIONS

lubrication systems CME Electric pump for oil and soft grease volumetric

FilterMax F. Modular dust collector with integrated pre-separator

altec Alta Tecnología de Vanguardia S.A. de C.V.

FilterMax F. Modular dust collector with integrated pre-separator

THREADED VALVES PENTAIR CLEAN AIR SYSTEMS

Quickstepper FSS Key features

Pressure Transmitters

POWER PULSE VALVES integral pilot (external exhaust) threaded or Quick Mount connection 3/4 to 1 1/2

BC-VDC A TOTAL SYSTEM FOR YOUR DUST COLLECTOR DWYER INSTRUMENTS, INC. DWYER OFFERS YOU:

DKG-114 MANUAL AND REMOTE START UNIT

Indirect servo-operated 2/2-way solenoid valves Type EV220W 10 - EV220W 50, NBR and EPDM versions

12 TANKS WITH 2½ AND 3 VALVES HEADER TANK SOLUTIONS PENTAIR CLEAN AIR SYSTEMS

FilterMax F. Modular dust collector with integrated pre-separator. Models

FilterMax DF. Modular dust multi purpose collector. Models

GOYEN DRESSER NUT VALVES CLEAN AIR SOLUTIONS PRODUCT LEAFLET

Explosion-Protected Pressure Switches

FilterMax DF. Modular dust multi purpose collector. Models

Type 2511/12. Type Type 2030 Cable plug. ASI cable plug. Dosing control. General technical data Orifice Type 6518

GOYEN T SERIES THREADED VALVES CLEAN AIR SOLUTIONS PRODUCT LEAFLET

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

-M- Flow rate 100 l/min. M5 Compact System Key features

Diaphragm/piston pressure switches 250 V

Level limit switch Series CN 4000 Selection list. Specifications 2. Applications 4

Electropneumatic Converters i/p Converters Type 6111 Mounting and Operating Instructions EB 6111 EN

SF-1000 workbench - welding table. User s Manual.

6 & 8 TANKS WITH 1½ VALVES HEADER TANK SOLUTIONS PENTAIR CLEAN AIR SYSTEMS

Pressure switch hex 27

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

The Vario motor-driven pump series from ProMinent Adaptable to a wide range of applications VARIO METERING PUMP

Shut-off dampers. Type AK-Ex. For low-leakage shut-off of volume flows in potentially. explosive atmospheres (ATEX) PD AK-Ex 1.

Compact differential pressure switch Models DC, DCC

The New Filter Valve Technology

Assisted lift operated 2/2-way solenoid valves Type EV251B

PXN12C DXN25C DXN37C MULTI-CONTACT CONNECTORS 10 A TECHNICAL FEATURES

Application Engineering

CPLab / CP Factory. Application module magazine. Data sheets

Servo-operated 2/2-way solenoid valves Type EV220A

High Flow Valve Actuation Range. NAMUR Valves G1/4" & G1/2" Piped Valves G1/4" & G1/2" Banjo Valves G1/8" & G1/4"

Series P215PR Direct Mount Pressure Actuated Condenser Fan Speed Controllers For Single Phase Motors (incl. built-in RFI suppression filter)

ISE/N Automatic valve

AUTO-EC-3-E-PLC Electric Filter Backwash Controller Operation & Maintenance Manual

PRESSURE MONITORING.

Actuators & Positioners Electro-Pneumatic Converters I/P Signal Converters - TEIP 11 Model without Booster Stage

Documentation. RM-BV4 Micro DP. Filter control

MM & MR SERIES MANIFOLD MOUNT VALVES PENTAIR CLEAN AIR SYSTEMS

PULSE VALVES. Pulse Valves. for Dust Collector Filters

Solenoid valve Types EV220B 15 - EV220B 50

DMP 333. Industrial Pressure Transmitter For High Pressure. Stainless Steel Sensor

Soliswitch FTE30. Technical Information

10 mm solenoid valves on manifold with multiconnection D-SUB

FilterMax DF. Modular dust multi purpose collector

Redundant Control System

Pressure switches hex 24

Level limit switch Series RN 4000 Selection list. Overview / Specification / Applications

Head-separated Digital Pressure Sensor DP5 SERIES DPH SERIES

Electronic Wiper Control

BC 4.3. Gas Tight Dampers GTD-GB40-B-E LISTED

Application Engineering

Control Stations & Switches: Control Stations Increased Safety Unicode 2 Series: Pre-drilled Control Stations

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

SITESTAR ELECTRONICS CABINET DESCRIPTION

Pressure transmitters for heavy duty applications MBS 3200 and 3250

Electro-pneumatic control valves

VALVE CONTROLLERS Controllers for Dust Extr 2010 / 2011 action Technology

Type AK-Ex FOR LOW-LEAKAGE SHUT-OFF OF VOLUME FLOWS IN POTENTIALLY EXPLOSIVE ATMOSPHERES (ATEX)

DMP 331 DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial

MINI-SOLENOID VALVES ISO (CNOMO, size 15) interface direct operated, pad mounting body connector size 15

COMPONENTS FOR OIL-FIRED HEATING

Miniature I/P, E/P Transducer

Solenoid valves, 2/2-way servo-operated type EV220B 6-22

SATRON VTe pressure transmitter

Pressure transmitter for general industrial purposes MBS 3000 and MBS 3050

SolidFlow. Monitoring of Solids. Product Information. SWR engineering Messtechnik GmbH

About Dustcontrol Filter Units

Improving your workspace

INDUSTRIAL AIR FILTRATION SYSTEMS PLTF JET-PULSE PLEATED BAG HOUSE FILTER

Control Solutions Biofloor

Level limit switch Series RF 3000 Selection list

Emotron DCM Control Unit

LCP Cartridge Dust Collector

Special valves. Series. Solenoids. IP65 (with connector) Zones 1, 21 II 2 G II 2 GD EEx me IP64. Aluminium. Operation. Page no. EEx me IP65.

F01 Electric Actuators

4 qwer. Main Pulse Valves Dust Collector 2/2 SERIES H OME PAGE P RINT. High Flow. Aluminum Bodies Air and Inert Gas 3/4" to 3" NPT.

Transcription:

MPS AND MPS PR¼ 16 OUTPUT DEMAND PENTAIR CLEAN AIR SYSTEMS

MPS DESCRIPTION The Model MPS has been designed to guarantee the control of diaphragm valves mounted on pulse-jet dust collector filters containing filter bags or cartridges. The main function of the MPS is to ensure the filter is cleaned only when it exceeds the set ΔP. All the technical characteristics comply with the CE Directive. The MTS-PR¼ conforms to the European Directive (89/336 EEC and 93/68 EEC). Upon request it is possible to supply the unit in accordance to the European Directive EC/94/9 ATEX, ATEX II 3D (zone 22). The MPS sequencer is available in the following versions: MPS4, MPS8, MPS12, MPS16. The MPS unit visualises all the values set, via a digital display (Operating ΔP, pulse time, pause time, number of shut-down cleaning cycles). The pause time used when in shut down cleaning mode is the same as the pause time set when in manual mode. The MPS unit also has the PRECOATING function, which allows the user to set a higher value of ΔP than normally required. (This is normally possible only once when the filter is new or when the filtering elements are new.) This function is used in filters where it is necessary to ensure that the filtering elements absorb special reagents which act as a further protection. By setting a higher ΔP value (Precoating ΔP value), it allows the filtering elements to properly absorb the reagents injected into the filter. Once the Precoating ΔP value has been reached, the pulsing will commence and will cease once it reaches the normal operating DP value. This value will no longer be considered in the normal functioning of the filter. MAIN FEATURES Operates in MANUAL or AUTOMATIC (ΔP) mode Automatic start-up of cleaning cycle according to set ΔP SHUT-DOWN CLEANING with selectable number of cleaning cycles PRECOATING function for new filters or filters equipped with new filtering elements REMOTE function ALARM contact enabling connection to external alarms HOUR COUNTER ΔP value playback (option) 4 20 ma ΔP output (optional) 03

MPS DIMENSIONS MPS 4 16 (mm) TECHNICAL CHARACTERISTICS Enclosure Protection rating Dimensions Weight ABS grey transparent cover IP65 MPS 4-8-12-16 outlets: enclosure 213 185 133 mm Approx 2 kg Connections Terminal blocks max. section 2,5 mm 2 Temperature Power inlet Outlet power Absorbed power Relay Storage: 20 C/+80 C Operation: 10 C/+50 C, with duty cycle (intermittent) 30% Standard: 115/230 V AC (±10%), 50/60 Hz (Selectable via jumpers) * Standard: 24/115/230 V AC 50/60 Hz (In and Out upon Request) IN OUT 24 V DC Without outlet: 25 V A 20 W 2 A 250 V AC Main fuse 500 ma delayed 115/230 V 2 A delayed 24/48 V Pulse time Pause time Pause time in automatic Operating ΔP Set alarm ΔP Shut-down cleaning Remote control ΔP precoating Hour counter 0,01 9.99 sec. 0 99 cycles Optional: 24/48 V AC (±10%), 50/60 Hz Optional: 48 V AC To be operated from a non-powered external contact (normally open). 0.01 2.49 kpa 0 65.999 hours 04

MPS PR¼ DESCRIPTION The Model MPS PR¼ 24/DC economiser is an integrated model which incorporates the remote pilot valves, model PR¼, which can be pneumatically connected to the diaphragm valves type VEM rather than with electrical connections. This version has been designed to guarantee the control of diaphragm valves mounted on pulse-jet dust collector filters containing filter bags or cartridges. All the technical characteristics comply with the CE Directive. The MPS PR¼ conforms to the European Directive (89/336 EEC and 93/68 EEC). Upon request it is possible to supply the unit in accordance with the European Directive EC/94/9 ATEX, ATEX II 3D (zone 22). The pilots are mounted within the enclosure, are pre-wired and have a ¼ Gas female thread to be used for the pneumatic connections between the remote pilot and the diaphragm valve. The MPS PR¼ is available from a minimum of 2 pilot valves to a maximum of 16 pilot valves mounted within the enclosure. MAIN FEATURES Automatic start-up of cleaning cycle according to set DP Remote pilot valves (brass) pre-wired in enclosure complete with electronic economiser controller PRECOATING function for new filters or filters equipped with new filtering elements Operates in MANUAL or AUTOMATIC (ΔP) mode SHUT-DOWN CLEANING with selectable number of cleaning cycles REMOTE function ALARM contact enabling connection to external alarms HOUR COUNTER DP value playback (option) 4 20 ma ΔP output (optional) GENERAL CHARACTERISTICS Fluid Air inlet Operating pressure Exhaust Air dry and oil free ¼ Gas From 0.5 to 7.5 bar 1 8 Gas CONSTRUCTION CHARACTERISTICS Pilot body Pilot Lock nut O-ring Brass Brass Zinc plated NBR 05

MPS PR¼ DIMENSIONS SEQUENCER MPS2 6 - PR¼ SEQUENCER MPS7 12 - PR¼ TECHNICAL CHARACTERISTICS Enclosure Protection rating ABS grey transparent cover IP65 Connections Terminal blocks max. section 2,5 mm 2 Temperature Power inlet Absorbed power Relay Storage: 20 C/+80 C Operation: 10 C/+50 C, with duty cycle (intermittent) 30% Standard: 115/230 V AC (±10%), 50/60 Hz (Selectable via jumpers) Without outlet: 25 V A 20 W 2 A 250 V AC Main fuse 500 ma delayed 115/230 V 2 A delayed 24/48 V Pulse time Pause time in manual Pause time in automatic Operating ΔP Set alarm ΔP Shut-down cleaning Remote control ΔP precoating Hour counter 0.01 9.99 sec. 0 99 cycles To be operated from a non-powered external contact (normally open). 0.01 2.49 kpa 0 65.999 hours Optional: 24/48 V AC (±10%), 50/60 Hz 06

CLEANAIRSYSTEMS.COM 2014 Pentair Clean Air Systems reserves the right to change product designs and specifications without notice. Mecair 16 Output Demand Controller EU Compliant Rev02 02/15