Feasibility Study of 4x10G CWDM - Potential Evolution of Technology - IEEE 802.3ba Interim Meeting Seoul, September 16-19, 19, 2008

Similar documents
100G PAM PMD Observations

SFP Fiber Optic Transceivers

Optical Specifications of SMF PMDs Study. 400 Gb/s Ethernet Task Force IEEE Interim Meeting 8-10 September 2014 Ottawa, Canada Chris Cole

fiber optic cable Outdoor Cables

10GBASE-LRM over 300m of FDDI-grade Fiber

40G QSFP+ (MPO) to 4x10G SFP+ (8xLC) Assembly

Get Fiber Smart. Part 1 : Best Practices in Enterprise Fiber Connectivity. Part 3: Best Practices in Tier2 Enterprise Fiber Link Testing and

Fiber Optics. Cage for Small Form Factor Pluggable (SFP) Transceiver V23818-S5-N1 V23818-S5-N1-BB

Products design and Application with BD180 Process

This is the H-bridge in it's off position. All four switches are turned off and no power is provided to the motor.

Viking Series 10/100Base-TX/FX, Auto MDI/MDIx, Autonegotiable MIL-DTL-38999, Unmanaged Ethernet Switch

UNCLASSIFIED. Revised: 8/21/15 UNCLASSIFIED Page 1 of 6

Mining and Petrochemical Tray-Rated Fiber Optic Cables

Fiber Optic, Breakout cable, tight buffered, 900 microns

F485 Communications Converter

Dell Networking W-7200 Series mobility controllers

ATC Series XFP CP Active Transceiver Cooler

Versatile Transceiver and Transmitter Production for Phase I Upgrades of LHC Experiments

ezspan ADSS Short Span All-Dielectric Self-Support Loose Tube Cable

Construction 2-24 tightly buffered fibres 900 m 50 m. colour code 1 Red 13 Yellow w/mark every 70 mm 2 Green 14 White w/mark every 70 mm 3 Blue 15 Gre

Optical Fibre Fibre Cables

Speed Enhancement for the 3rd-Generation Direct Liquid Cooling Power Modules for Automotive Applications with RC-IGBT

SW1 Swivel 1U Patch Panel

LX2 High Density LGX 4U Patch Panel

OFS 400A FIBER OPTIC INTERCONNECT Instruction Sheet UNIT (FOIU) Comcode INSTALLATION

LC Cable Assemblies. Fiber Optic Products Catalog. Product Facts. LC Cable Assembly. Hybrid LC-SC Cable Assembly

LX2 High Density LGX 4U Patch Panel

SW1 Swivel 3U Patch Panel

OPTICAL TRANSCEIVER SPECIFICATIONS GUIDE. Optics DACs Cables Cable Management Media Converters

Maxim Integrated Products 1

System configurator and order-information guide Oct Top-of-Rack Ethernet Switch - PSWITCH 2048T S26361-F3986-L405

RS485 board. EB062

Laser Optimized Multimode

Construction 2-24 tightly buffered fibres 900 m 50 m. colour code 1 Red 13 Yellow w/mark every 70 mm 2 Green 14 White w/mark every 70 mm 3 Blue 15 Gre

50µm µlinx Avionics Cable

Splice Trays. features and benefits. specifications. A LANscape. Solutions Product. Splice Capacity

Camera Electronics Systems

IBER DISTRIBUTION FRAME (FDF) FOR EXCHANGE SIZE 900MM x 2200MM x 300 MM

No. Tool Vendor P/N. Furukawa FITEL Furukawa FITEL Furukawa FITEL Furukawa FITEL Furukawa FITEL Furukawa FITEL Furukawa FITEL.

Peel Grinding. High speed peel grinder from Weldon Solutions

Analyzing Feature Interactions in Automobiles. John Thomas, Ph.D. Seth Placke

MTP Loose Tube Trunk Assemblies. Features. Applications.

596 Rectifier Retrofit

Present Status and Prospects for Fuji Electric s IC Products and Technologies Yoshio Tsuruta Eiji Kuroda

FL2000 Termination/Splice Panels User Manual

FOL14xx Series (with Isolator) August 2017

Applications. General technical specifications according to ISO Parallelism 1

ATC Series QSFP CP Active Transceiver Cooler

Li-Ion Charge Balancing and Cell Voltage Monitoring for Performance and Safety

Reasons for reissue of this instruction sheet are provided in Section 8, REVISION SUMMARY.

Introduction to Fiber Cable Assemblies FiberDeep and Cable Assemblies

Tools. Features. KIT Installer tool

Technical Data Sheet Chip LED with Bi-Color(Multi-Color)

Est DCM Double Conversion Module 400kVA - 800kVA

Multilink s Family of Wall Mount Enclosures

Evaluates: MAX14775E/MAX14776E. MAX14775E Evaluation Kit. General Description. Features. Quick Start. Startup Procedure. Required Equipment

Expansion Modules for Dell PowerConnect Switches

(3) 2-Loop B&W PWR s Unit 1- Commissioned 7/5/1973 Unit 2- Commissioned 9/9/1974 Unit 3- Commissioned 12/16/ MW per unit for a total of 2880 MW

TAT120015AC8XX TJT120015AC8XX

Gasoline PN Fuel Influence UPDATE

Breakout Session 1 Report-out presentations

350 ma CONSTANT CURRENT LED DC MODULE, 17 LINEAR, 1845 LUMENS

Volition Fiber Optic Cable

100GE PCS Modeling. Oded Trainin, Hadas Yeger, Mark Gustlin. IEEE HSSG September 2007

Weatherproof Tubular Slip Ring Assembly

R&D: FUTURE-PROOFING THE BMW GROUP. DR. HERBERT DIESS MEMBER OF THE BOARD OF MANAGEMENT OF BMW AG, DEVELOPMENT

Eco-Mobility 2025 plus Technologies for 75 g CO 2 /km in Wolfgang Kriegler (A3PS) November, 9 th 2015

Modular Multilevel Submodules for Converters, from the State of the Art to Future Trends

SPECIFICATION FOR APPROVAL

3rd International Conference on Material, Mechanical and Manufacturing Engineering (IC3ME 2015)

THE POWER TO LEAD CAT INDUSTRIAL ENGINES WITH ACERT TECHNOLOGY

Specification YGHR411-H CUSTOMER SUPPLIER. Rev.01 December Document No. : SSC-QP (Rev.00)

Transmission Technology contribution to CO 2 roadmap a benchmark

ENGEL e-motion TL. All-electric, tie-bar-less. be the first.

Value Paper Author: Mats G Olsson. IDC, Interstand Dimension Control Field experience at Shiu Wing Steel, Hong Kong

Construction of a Hybrid Electrical Racing Kart as a Student Project

BROCHURE. IE4 SynRM motor-drive packages Super premium efficiency for industry

High Speed V-Series of Fast Discrete IGBTs

FY st Half Results (from April 1, 2013 to September 30, 2013)

S24SP15004 series 60W Single Output DC/DC Converter

Newly Developed High Power 2-in-1 IGBT Module

Datasheet Outside Plant Cable

Introduction of large DIPIPMP conditioner inverter. application on EV bus air. Abstract: 1. Introduction

Assessment of Smart Grid Applications for the City of Palo Alto. City of Alameda Public Utilities Board September 19, 2011

Instruction Sheet Simplex and Duplex. LightCrimp Plus LC. Fiber Optic Connector Kits Feb 2017 Rev E

Alan Kilian Spring Design and construct a Holonomic motion platform and control system.

ezspan ADSS All-dielectric self-supporting loose tube cable

STU in Lapland. Table 1

1 8 WK L_V_AUTO_V01 FEB

Power Your Ride. Seminar Series. STMicroelectronics is pleased to present the. Detroit June 7, 2016 Santa Clara June,

FITEL S153A Ver.2 Hand-held Active Alignment Splicer

Hello, my name is Takehiro Kamigama. I will present the full-year consolidated projections for fiscal 2015.

Mitsubishi Electric Semi-Conductors Division. IGBT Module 7th Generation T-Series. June 14, 2018

MIC Plenum Cables, 2-24 Fibers

Volition. Fiber Optic Cable. 3Innovation

15-22/R6G6C-A32/2T SMD B

Additive Manufacturing at MTU

Agency Approvals UL and CSA China RoHS - Below MCV Yes Color Red EU RoHS Compliant Yes Maximum Recommended Voltage Rating 600 Volt Units per Box 100

Universal Network Zone System Part Numbers: Z23U-****

Printer-friendly format 3M Scotchlok Electrical Spring Connectors Y- BOX 5-8#22, 4-6#20, 2-5#18, 2-3#16 AWG, 100 per box, Yellow. Learn More...

Transcription:

Feasibility Study of 4x10G CWDM - Potential Evolution of Technology - IEEE 802.3ba Interim Meeting Seoul, September 16-19, 19, 2008 Eddie Tsumura (ExceLight Communications, Inc.) Kengo Matsumoto (Sumitomo Electric Industries, Ltd.)

2 Outline Block diagram of 4x10G CWDM 1 st generation 4x10G CWDM 2 nd generation 4x10G CWDM Expecting evolution Compact TOSA with OMUX Power reduction strategy Example (10GBASE-LR SFP+) Power consumption table update OSA relative cost estimation at 2010 Summary

3 Block Diagram of 4x10G CWDM CPU I2C DAC DML Driver TOSA DML Driver DML Driver TOSA TOSA OMUX Module Connector DML Driver TOSA SC Duplex PIN- ROSA PIN-ROSA PIN-ROSA ODMUX PIN-ROSA

1 st Generation 4x10G CWDM - High-lights and Low-lights - High-lights Discrete 10G TOSA and ROSA is used with OMUX/DEMUX module TOSA can leverage 10GBASE-LR transceiver quantity 4x10G CWDM wavelength range (1264.5 to 1337.5nm) is within 10GBASE-LR wavelength range (1260 to 1355nm) and CWDM LD for 4x10G can be used for 10GBASE-LR ROSA can leverage 10GBASE-LR/OC192-SR1/IR2 transceiver quantity No additional design effort is required for ROSA Fusion splice or pigtail w/ optical connector will be used IC can leverage XFP transceiver quantity LD driver IC can leverage 10km XFP/SFP+ transceiver quantity Manufacturing process can leverage existing system for 10km XFP/SFP+ Investment for equipment and tool for manufacturing is minimal Manufacturing process is so matured and easy to reduce inspection time by key component pre-screening or guaranteed performance by design Low-lights Difficult to reduce transceiver size (Up to double size of X2 transceiver) Not manufacturing friendly owing to fiber pigtail assembly 4

5 2 nd Generation 4x10G CWDM - Expecting Evolution - Small Form Factor Appropriate level TOSA/OMUX integration is the key Maintain same level transmitter performance with existing 10G transceiver Maintain ease of manufacturing as existing 10G transceiver level Investment for manufacturing and development have to be minimized ROSA/ODEMUX integration which is used for 10GBASE-LX4 is applicable to 4x10G CWDM because of low technical risk Appropriate level IC integration is required integration to 4ch from 1ch LD driver integration to Low Power Consumption Power reduction of optical transmitter is the key Appropriate level IC integration is required to remove circuit redundancy Using lower supply voltage as possible combined with high efficiency DC/DC converter

6 2 nd Generation 4x10G CWDM - Compact TOSA with OMUX - Combine a pair of 2-wavelength OMUX- TOSA with simple OMUX module Can fit to SC duplex width transceiver such as X2 transceiver Using diplexer style structure for OMUX-TOSA OMUX part has low cost design which is same concept as existing diplexer Can use same assembly technology and equipment for diplexer/triplexer whose market size is larger than 10Mpcs/year Doesn t require difficult transceiver PCB layout or difficult assembly without any transmitter performance degradation LD CAN part can leverage 10GBASE-LR transceiver quantity Complex optical alignment or tighter tolerance mechanical part is not required

7 2 nd Generation 4x10G CWDM - Power Reduction Strategy - Optical transmitter power reduction Reduce transmitter power reduction by circuit design optimization Reduce LD operating current by chip design optimization (Getting enough bandwidth at low operating current and high temperature) Minimize circuit redundancy by integration LD driver integration to can reduce output buffer and LD driver input buffer power consumption Using lower supply voltage as possible combined with high efficiency DC/DC converter

2 nd Generation 4x10G CWDM - Example (10GBASE-LR SFP+) - Incumbent Design After Optimization Optical waveform Optical input sensitivity Power consumption (0.25W saving) -17.1dBm @25degC, Vcc=3.3V 1.0W (compliant with SFP+ MSA power level 1) @70degC, Vcc=3.3V+10% -17.7dBm @25degC, Vcc=3.3V 0.75W @70degC, Vcc=3.3V+10% 25% power reduction is proved by actual SFP+ More reduction of 4x10G CWDM is doable by applying power reduction strategy 8

Item 2 nd Generation 4x10G CWDM - Power Consumption Table Update - 2008 (4xSFP+ and 4x) 9 2008 2010 DML TOSA w/omux 3.0W 1) 4 x DML Driver (4xSFP+) 1.7W 1.5W 4 x PIN-TIA ROSA w/odemux 0.64W 0.5W Other 0.2W 0.1W 2) 4 x 1.8W 1.8W 1.0W Total 4.8W 4.34W 3.1W 1) Including 100mW/ch power consumption for limiting amplifier which can be integrated in, and including 65mW/ch power consumption for other circuit such as CPU which can be reduced by sharing CPU. 2) Assume to use low power CPU

2 nd Generation 4x10G CWDM - OSA Relative Cost Estimation at 2010 - Item 10GBASE-LR 10GBASE-LX4 40GBASE-LR4 DML TOSA w/omux 2 6-7.5* 12-15* 4 x PIN-TIA ROSA w/odemux 1 2-2.5* 4-5* OSA total 3 8-10* (2.7xLR-3.3xLR) 16-20* (5.3xLR-6.7xLR) *) Relative cost estimation depends on vertical integration effect. Item 10GBASE -LR 40GBASE -LR (traverso_ 02_0708) 40GBASE-LR4 traverso_ 02_0708 10 tsumura_ 01_0908 OSA total 1 5.9 8.4 5.3-6.7 No significant OSA cost is assumed between 40GBASE-LR4 and 40GBASE-LR

11 Summary 1 st generation 4x10G CWDM is ready with maximum power consumption of 4.8W and double size of X2 transceiver. 2 nd generation 4x10G CWDM requires new 4x10G CWDM TOSA w/omux and ROSA w/odemux to realize X2 transceiver size. However, its investment will not be so large by leveraging diplexer technology for TOSA and LX4 technology for ROSA. Also, maximum power consumption of 3.1W is feasible in 2010. It may allow to use 40GE SMF 10km transceiver for high port density application.