Engine Model: 4B3.9-G1 Engine Technical Data No. of Cylinders / Alignment: Cycle: 4 / In Line 4 Stroke Bore / Stroke: mm 102/120 Induction: Cooling Me

PRAMAC GBW 45. Main features. GBW Series. Item code: SB450TPAY kw. Standby power LTP. 34 kw. Rated prime power (PRP)

LSP88S3. Powered by 50HZ. Water-cooled. Three Phase. Diesel KVA 88 KW 70. Standby Power

EP series WPS800S rpm,3-phase/5-wiring

TPD2250H6.3 TECHNICAL DATA

JCB DIESEL GENERATOR TECHNICAL SPECIFICATIONS

PGCLS Hz/1800 r.p.m-p.f.0.8 Prime Power Standby Power Rated Current Genset Engine Alternator Voltage(V) PH kw/kva kw/kva Amps

WCS2000 / WCS2000S. Features: WCS Series

DIESEL GENERATOR SET MTU 12V1600 DS660

PGDLS352KW 380/ / / / / / / / /

PGPLS45. 60Hz/1800 r.p.m-p.f.0.8 Prime Power Standby Power Rated Current Genset Engine Alternator Voltage(V) PH kw/kva kw/kva Amps 240 ( )

PGDLS / / / / / / / / /

LSC220S3. Powered by Cummins 50HZ. Water-cooled. Three Phase. Diesel KVA 220 KW 176. Standby Power

EC series GMS30CS-AU 50

PGDLS200. Overall Dimensions (mm) & Weight (kg) Length:3900. Width:1140. Height: 1850

EP series WPS100S-AU rpm,3-phase/5-wiring

PGPLS215Kw. 60Hz/1800 r.p.m-p.f.0.8 Prime Power Standby Power Rated Current Genset Engine Alternator Voltage(V) PH kw/kva kw/kva Amps

JCB DIESEL GENERATOR TECHNICAL SPECIFICATIONS

JCB DIESEL GENERATOR TECHNICAL SPECIFICATIONS

LSC500S3. Powered by Cummins 50HZ. Water-cooled. Three Phase. Diesel KVA 500 KW 400. Standby Power

DIESEL GENERATOR SET MTU 4R0113 DS80

Better Soundproof, Better Life!

60Hz/1800 r.p.m-p.f.0.8 Prime Power Standby Power Rated Current Genset Engine Alternator Voltage(V) PH kw/kva kw/kva Amps 240 ( )

PGDLS / / / / / / / / /

JCB DIESEL GENERATOR TECHNICAL SPECIFICATIONS

PGKT / / / / / / / / / / / /

DIESEL GENERATOR SET MTU 10V1600 DS500

PRO Rental Product Range. PRO60-2 (R96 EUIIIa Equivalent) KEY FEATURES. Rental Ready Features. Alternator. Integrated Voltage Regulator (IVR)

DIESEL GENERATOR SET DG00660D5

AP59-6. Model Name AP59-6 Frequency / PF 60Hz, 1800 rpm, 0.8pf. Engine Make & Model Perkins 1103A-33TG1 Alternator Make Stamford

PRO Rental Product Range. PRO100-2 (EUIIIa Compliant) KEY FEATURES. Rental Ready Features. Alternator. Integrated Voltage Regulator (IVR) Enclosure

CUMMINS 30KVA. Voltage kva kw kva kw Amp 400/230 30,00 24,00 27,00 21,60 38,00

60Hz/1800 r.p.m-p.f.0.8 Prime Power Standby Power Rated Current Genset Engine Alternator Voltage(V) PH kw/kva kw/kva Amps

PGPLS10. 60Hz/1800 r.p.m-p.f.0.8 Prime Power Standby Power Rated Current Genset Engine Alternator Voltage(V) PH kw/kva kw/kva Amps 240 ( )

Weifang Ricardo Generator

GMS1400C / GMS1400CS. Features: EC Series

EP series WPS150BS-AU rpm,3-phase/5-wiring

Super Silent, Superior Life!

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

PRO Rental Product Range. PRO275-2 (EUIIIa Compliant) KEY FEATURES. Rental Ready Features. Alternator. Integrated Voltage Regulator (IVR) Enclosure

Voltage kva kw kva kw Amp 400/ ,00 88,00 100,00 80,00 144,00

Voltage kva kw kva kw Amp 400/ ,00 160,00 180,00 144,00 259,00

GKP 660KVA. GKP Series. Generator Set Specification. Ultra Silent, Extended Life!

Annex A TECHNICAL SPECIFICATION FOR SUPPLY, INSTALLATION, TESTING AND COMMISSIONING OF 400V (750KVA) DIESEL

GE.VO.360/325.SS+0_all

GE.PK.022/020.SS+0_all

Voltage adjusting range % Voltage stabilization time(100% load sudden reduce) 3. Voltage fluctuation rate: Frequency volatility ±0.

GKP 550KVA. GKP Series. Generator Set Specification. Ultra Silent, Extended Life!

GENSET MODEL: JM1640G TECHNICAL DATE SHEET

DIESEL GENSET. Prime Hz 16 kw / 20 kva. Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva

HFW-350 T5. Generating Rates SERVICE PRP STANDBY. INDUSTRIAL RANGE Soundproof Powered by FPT_IVECO

P 602. This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

HDW-200 T5. Generating Rates SERVICE PRP STANDBY. INDUSTRIAL RANGE Soundproof Powered by DOOSAN

P 602. This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

APD-NG400. NG Standby Power

DIESEL GENERATOR SET DE110E2. Output Ratings. Technical Data. EU stage II emissions compliant. Image shown may not reflect actual package.

KVAR POWERHOUSE RANGE 140 KVA 200 KVA

WPS10S. EP Series. Generator Set Specification. Super Quiet, Superior Life! 广泛应用于通讯 工业 租赁. Widely applied in Telecom, Industry, Rental, 户外工程 矿山 军事等领域

50 HZ 60 HZ. l Standard ambient temperatures up to 50 C (122 F) l Fan, fan drive and charging alternator fully guarded

50 HZ 60 HZ. l Standard ambient temperatures up to 50 C (122 F) l Fan, fan drive and charging alternator fully guarded l Antifreeze protection coolant

DIESEL GENSET. Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva

P 602. This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva

APD-ULJ250. Standby Power

DIESEL GENERATOR SET DE220E0. Output Ratings. Technical Data. Image shown may not reflect actual package. Standby* Generator Set Model - 3 Phase

DIESEL GENERATOR SET DE110E2. Output Ratings. Technical Data. EU stage II emissions compliant. Image shown may not reflect actual package.

Voltage adjusting range % Transient voltage deviation(100% load sudden reduce) +20% Transient voltage deviation(load impact)

DIESEL GENSET. Prime 60Hz 36 kw / 45 kva

DIESEL GENERATOR SET DE165E0. Output Ratings. Technical Data. Image shown may not reflect actual package. Standby* Generator Set Model - 3 Phase

Rating Definitions and Conditions

Prime 60Hz 155 kw / 193 kva. Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva

Super Silent, Superior Life!

50 HZ. l Outgoing cable stub-up area directly below circuit breaker. l Voltage regulation ±0.5 % l Provides fast recovery from transient load changes

APD-ULM2000. Engine Alternator Voltage Standby Power Power Factor. PI734E (Wnd-312) 480 / 277V 2000kW A N.A.

DIESEL GENERATOR SET DE110E2. Output Ratings. Technical Data. EU stage II emissions compliant. Generator Set Model - 3 Phase Prime* Standby*

Model NA 2 L

RENTAL DIESEL GENERATOR SET

50 HZ. l Outgoing cable stub-up area directly below circuit breaker. l Voltage regulation ±0.5 % l Provides fast recovery from transient load changes

50 HZ 60 HZ. l Standard ambient temperatures up to 50 C (122 F) l Fan, fan drive and charging alternator fully guarded l Antifreeze protection coolant

50 HZ. l Outgoing cable stub-up area directly below circuit breaker. l Voltage regulation ±0.5 % l Provides fast recovery from transient load changes

Super Silent, Superior Life!

50 HZ. l Outgoing cable stub-up area directly below circuit breaker. l Voltage regulation ±0.5 % l Provides fast recovery from transient load changes

Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva

PRO Rental Product Range. PRO150-1 (Fuel Optimised) PRO150-2 (EUIIIa Compliant) KEY FEATURES. Alternator. Rental Ready Features

DIESEL GENSET. Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva

WPS137S. EP Series. Generator Set Specification. Super Quiet, Superior Life! 广泛应用于通讯 工业 租赁. Widely applied in Telecom, Industry, Rental, 户外工程 矿山 军事等领域

Power Factor Factor Cos = 0.8. Prime Power Standby Power Rated Current Fuel Consumption (PRP) (ESP) Amps

50 HZ. l Standard ambient temperatures up to 50 C (122 F) l Fan, fan drive and charging alternator fully guarded l Antifreeze protection coolant

Rating Definitions and Conditions

Transcription:

Features: engine Alternator, Class H Genset Canopy N/A protection, Control panel IP56 protection Control module PLC-920 Breaker: Speed governor: Electronic governor Excitation system: Brushless A.V.R model: SX460 50 radiator Big daily fuel tank(below 800KVA) Fire extinguisher Oil pump on the engine ATS receptacle Lockable battery isolator switch Vibration isolators between the engine/alternator and base frame Integrated wiring design High water temperature protection Output Ratings Generator Set Prime Power Standby Power Model kva kw kva kw GMP80PX 80 64 103 82 Ratings at 0.8 power factor Dimensions and Weights Ratings and Performance Data Model L W H-mm Dry Weightkg Engine Brand Engine Model 4DTA4.8ECG2 GMP80PX 2156 881 1495 1196 Alternator Brand Notes: *Prime Power Continuous duty operation, under variable load 24/24h-10% over load permissible 1 hour/12 hours; **Standby Power Standby duty, operation under variable load, without over load; Standard Reference Conditions Note: Standard reference conditions 25 C (77 F) Air Inlet Temp, 100m(328 ft) A.S.L. 30% relative humidity. Alternator Model Control Circuit Breaker Type Frequency / Phase PL2DS PLC-920 Engine Speed(RPM) 1500 Fuel Tank Capacity(L) 206 Fuel Consumption(L/h) (100%load) Model Type 50Hz/3Phase 19.8 Open Type Standard Package Noise Level@7m(dBA) Generator set Manufacture N/A Oil Consumption(L/h) 1.53 Volatage(V) 380/400/415/440 Silencer Noise Reduction(dBA) 10-12 www.powerlinkworld.com info@powerlinkworld.com 1/7

Engine Model:4DTA4.8ECG2 Engine Technical Data Engine Model Engine Brand Number of Cylinders 4 Cylinders Arrangement 4DTA4.8ECG2 Inline Bore/Stroke(mm) 110/125 Speed(RPM) 1500 Displacement(L) 4.75 Compression Ratio 17 Air Intake system Cooling Method Coolant Capacity(L) 6 Prime Power(kWm) 82 Standby Power(kWm) 90 Governing Type Back Pressure(mmhg) 6 Battery(V) 12 Fuel Fuel Tank Turbocharge aftercooler Water cooled Electronic steel Fuel Tank Capacity(L) 206 Fuel tank type Recommended Fuel Type Injection Fuel Consumption: GMP80PX 100% 75% Single-layer 0# or ASTM2 Direct injection 50% 25% L/h 19.8 15.6 10.8 6.4 Exhaust and silencer Exhaust Air Flow(m³/hr) 1040.4 Exhaust Air Temp.( C) Maximum Allowable Back Pressure(mmhg) NOx(mg/Nm³) Silencer Quantity 1 Silencer Type Cooling N/A 6 N/A Radiator 50 Coolant Capacity(L) 6 Coolant Change Time(Year/h) 2/10000 Coolant Intake Temp.( C) 76 Coolant Output Temp.( C) 99 Industrial silencer Designed to operate in ambient conditions up to 50 C (122 F).Contact your local Dealer for power ratings at specific site conditions Air Intake system Air Filter Type Dry type Intake Air Flow(m³/h) 399.6 Intake Intake Air Temp.( C) 25 Turbocharge aftercooler (Based on diesel fuel with a specific gravity of 0.85 and conforming to BS2869,Class A2) Lubrication Lube oil label Maximum Oil Temp.( C) 100 Oil capacity(l) 14 Conditions Altitude(m) Ambient Temp.( C) -5-50 Barometric Pressure(kpa) 100 Relative Humidity <80% www.powerlinkworld.com info@powerlinkworld.com 2/7

Alternator Model:PL2DS Alternator Physical Data AVR Model SX460 Alternator Brand Alternator Model PL2DS Excitation Brushless Housing Protection IP23 Power Factor 0.8 Rated Stator Temp. rise( ) 125 Rotor Insulation Class H Voltage Fluctuation(no load to full load) ±0.5% Winding Pitch 2/3 Wiring Connection Series Star Performance Data Alternator Operating Data Overspeed(rpm) 2250 Voltage Reguation(Steady state) ± 1.0 % THF(BS EN60034-1) <50 TIF(NEMA MG 1-22) <2% Air Flow(m³/s)-Alternator 50Hz/60Hz 0.514 Altitude-Alternator(m) 1000 Voltage Technical Data Time constants/400v(ms) T d T d T do Ta Short-circuit current (3 IN / 10 s) SHORT CIRCUIT RATIO Reactances(Per Unit) Xd X'd X"d 0.042 s 0.012 s 1.1 s 0.012 s 300 % (3 IN) : 10s 1/Xd Voltage Prime Standby kva kw kva kw 380V@50Hz 80 64 88.0 70.4 400V@50Hz 80 64 88.0 70.4 415V@50Hz 80 64 88.0 70.4 415V@60Hz 98 78.4 107 86.24 440V@60Hz 98 78.4 107 86.24 480V@60Hz 98 78.4 107 86.24 www.powerlinkworld.com info@powerlinkworld.com 3/7

GMP80PX/ 1000024939 Overall Dimensions www.powerlinkworld.com info@powerlinkworld.com 4/7

Control www.powerlinkworld.com info@powerlinkworld.com 5/7

Product Standard Configuration Alternator Control Fuel Lubrication Cooling Alternator A.V.R PLC-920 Control Air Breaker External Cable Connection Cable Line Slot Base Fuel Tank Water Separator Fuel Prefilter Fuel Tank Drain Fuel Level Control Panel Display Oil Pan Lube Oil Drain Pump 50 Radiator External Water Inlet Protection Mesh for Fan and Revolving Parts Air intake system Exhaust system Shipment and Installation Safety protection devices Technical documents Air Filter Intake Air Filter Screen Intake Air Silencer Industrial Silencer Heat Insulation Protective Sleeve Exhaust Outlet with Flexible Heat Hand Protection Forklift Lifting Points Lifting Lug Dragging Hole Side Collision Avoidance Design Base Mounting Hole Earth Protection Oil Pressure Oil Level Water Temperature Water Level Speed External Emergency Stop Genset Operation Manual Engine Operation Manual Alternator Operation Manual Genset Test Report Ganset Circuit Diagram Genset Installation Drawings Maintenance Manual Maintenance Records Engine Water-Cooled Engine Battery Battery Switch Draining Oil Pump Standard Air Filter Radiator Core Guard Air Filter with Replaceable Cartridge Battery Charger Machine Body Baseplate with Retention Tank - - - www.powerlinkworld.com info@powerlinkworld.com 6/7

Optional Configuration Alternator Control Fuel Lubrication Cooling PMG Anti-condensation Heater Winding Temperature Measurement PLC-7420 Control PLC-8610 Control Leak Protection Device External Fuel Filling Device Fuel Level Gauge Fuel Three-Way Value Auto Refilling Diesel Auto Refilling Oil Lube Oil Preheater Lube Oil Temperature Sensor 45 Radiator 40 Radiator Supplied with Coolant Air intake system Exhaust system Voltage Wheel Braking Safety protection devices Forced Air Inlet Intake Air Preheating Residential Silencer 415/240V 400/230V 380/220V 220-240V-SINGLE PHASE 220/127V 480/277V 440/254V Trailer-Roadside Type Trailer-Off-Road Type Trailer Suspension RCD Protection Imbalanced Three-phase Spark-extinguishing Device Anti-lightning Installation Secure Transportation Open the Door Shutdown Protection Extinguisher Explosion-proof Lamp No-skid Floor Rest Area High-tech configuration Optional configuration Technical documents Engine - Remote Control Remote Communication and Diagnosis Remote Monitor Auto Start-Stop Alert Message Notification Maintenance Cycle Notification Three-way Catalytic Converter Engine Triple Painted Genset Parallel Installation External Fuel Tank SECC Base Frame Stainless Steel Exhaust 4 Poles Circuit Breaker ATS Quick Connector Fuel Leaking Protection Genset Parts Manual Engine Parts Manual Genset Tools Package Jacket Water Heater 220/240V Oil Heater Block Heater Heavy Duty Air Filter Specification may change without prior notice. For more info, please contact or your local distributors. RP Series / 2017-11-01 www.powerlinkworld.com info@powerlinkworld.com 7/7