Envirochem Testing Lab & Research Centre, Plot No. 165, Sector-25, Part-II, HUDA, Panipat, Haryana. Discipline Chemical Testing Issue Date

Comparator The system for colorimetric water analysis. Applications. Water Treatment (e.g. Drinking Water) Pool-Water.

Water analysis, QC and more:

Ecosteps Laboratory Pvt. Ltd., D-79, Sector-6, Noida, Uttar Pradesh. Discipline Chemical Testing Issue Date

Tintometer -Group. Comparator Highlights. The system for colorimetric water analysis

Discipline Chemical Testing Issue Date Certificate Number T-3037 Valid Until Last Amended on - Page 1 of 6

SAMPLING CONTAINERS & HOLDING TIMES. Parameters Method Holding Time 8 Minimum Volume Water Sampling Water Soil Water Soil Container Preservative 9

CHECKIT Comparator. with continuous colour scales. Pool & Spa Water Testing - January 2017

FACTORY PROFILE INTERMEDIATES UNIT-I-ANKLESHWAR

Plate Heat Exchangers

INTERPRETATION OF USED COOLANT ANALYSIS

TECHNICAL SPECIFICATIONS

Test papers Test strips

APPENDIX D WATER QUALITY DATA

VHG Labs, Inc. Standards and Supplies for Spectrochemical Oil Analysis

Eraring Power Station - EPA Licence Coal Unloader - EPA Licence Environmental Monitoring Data July 2016

10.6 Schedule of Accreditation

Product Bulletin. RCP Cooling System Treatment. Product Description. Primary Application

Physico-chemical Characterization of Water Body with Special Reference to Battery, Power Sources and Metal Plating Effluents

The Carnot Group. TCG Boiler Hire. Engineering Solutions. Whatever your steam needs we deliver. LPG Boilers ABN

Certificate of Accreditation

Bunkers: Qualifying Quality

Standard Analysis Report

MiniLab EL Series for High Performance Engine Development and Maintenance

CITY OF THE DALLES - CITY FEE SCHEDULE Effective June 1, 2016

TECHNICAL BULLETIN Coolant Types and their Purpose Issue: April 2015

Pretty catastrophic effects on both SX & EW operations.

PRICE LIST 2017/2018

A new era in asset protection

Container MBW12K90MC Thursday 25 Jan 2007

Fibertec 8000 Fully automated Crude and Detergent Fibre analysis

the experience of many

DETAILED EQUIPMENT SPECIFICATION MDAS SERIES DEALKALIZERS

HYDRO ION Water softener Type: VAD CS

CRS-A Series High Power Anti-Surge Resistor

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

CHEMICAL COMPOSITION OF WATER IN THE PUTAH CREEK BASIN. c. S. BISSON AND MARTIN R. HUBERTY

GF CALORPLAST Heat Exchangers day lead time on catalog products

BODY BUILDER INSTRUCTIONS Mack Trucks

The Measure of all Things. Volumetric Solutions from Merck

Conveyor Chains for Coal-Fired Power Stations

SHELL & TUBE HEAT EXCHANGER

Cost Effective Solution for the Efficient Cleaning and Decontamination of a Coker Unit

CDN Resource Laboratories Ltd.

SPIN KLIN GALAXY. Service & Maintenance Manual

Sampling kits and test suites

Monitor Chlorine in Crude at Sub-ppm Levels

Variation Notice with introductory note

Improve Steam Turbine Efficiency

The Modular System. Modular System

Techenomics Oil Analysis Information

VM, VMC, VMN. Vertical Multistage Centrifugal Pump, 60Hz

CERTIFIED & TESTED TO ISO-22241

Batteries & Fuel Cells Seminar. Seminar Program Topics. Seminar Schedule - April 7-8, full days. Seminar Location. In partnership with:

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

BEKOKAT The catalytic converter for efficient and reliable oil free air

ASTM Methods that are feasible with Metrohm instruments

Refinery Gas. Analysis by Gas Chromatography WASSON - ECE INSTRUMENTATION. Engineered Solutions, Guaranteed Results.

Safety 14 ga. Welded Plastic Bin Security Fire Resistant Gas Cylinder

/ I S S : / S T S I

Why Choose SRS Engineering?

ABC DRY CHEMICAL HAND HELD STORED PRESSURE FIRE EXTINGUISHERS

Direct steam injection sterilizer

INDUSTRIAL GENERATORS. steam or overheated water 97/23/CE - P.E.D. certified

SRP1238A Series - Shielded Power Inductors

Elemental Analysis Advanced

CarePacs. Traceable Balance Testing for Secure Weighing Processes

HORIZONTAL SPLIT CASING PUMPS TYPE : UP / UPL / UPH

Stamolys CA71SI. Technical Information

G40 Data Sheet D/EVO 120 e February 2017 Supersedes edition of September 2016

INDUSTRIES AMERICAN COOLAIR CORPORATION. Centrifugal Filtered Supply Roof Ventilators TYPE CFS - TYPE SIS

Selecting the Optimum Motion Control Solution for the Application By Festo Corporation

SIR Test Vehicles Comparison from a Cleaning Perspective

(*) H1 LUBRICANT WITH INCIDENTAL FOOD CONTACT:

ortable ph, Conductivity & DO2 Meters

COOLANTS. Tx COOLANTS PRODUCT GUIDE

High quality. Dosing pumps, BL series. Features

New Pig One Pork Avenue Tipton, PA Chemical Compatibility Guide for: FTI Pumps

Why we need new Total Nitrogen parameter and methods for CWA reporting. William Lipps Chief Science Officer, Eurofins Eaton Analytical August 2018

Guardian Packing Rings. Vortex Shedder Seals. Turbine Components. Custom Installation. Reverse Engineering

SAN ANTONIO WATER SYSTEM

Co-mingled Biosolids and Biomass as Feedstock for Steam Hydrogasification using a Lab-scale Batch Reactor

Etanorm GPV-D/CPV-D Etanorm GPV-W/CPV-W

MULTISTAGE PUMPS TYPE RKB

Product Engineering Bulletin

Corrosion in Underground Storage Tanks (USTs) Storing Diesel

are widely used because they provide a standardized surface for testing.

Model Q45H/ Residual Chlorine Monitor...

Electrical Machine Service. Overhaul, Conditioning, On-Site Service and Diagnostics. Excellent Technology, Efficiency and Quality

Surface Mount Multilayer Ceramic Chip Capacitors for Non-Magnetic Applications (IR Reflow Soldering)

QA/QC Antifreeze Program & Policy

NUTRICOTE Dependable controlled feeding of nursery, greenhouse, foliage, landscape, bedding and potted plants.

DUST PROCESSING AND INDUSTRIAL MIXING MATERIAL HANDLING EQUIPMENT

Radionuclide atomic number A 1 (TBq) A 1 (Ci) A 2 (TBq) A 2 (Ci) (TBq/g) (Ci/g) Ac-225 Actinium(89) x x

OIL ANALYSIS PROGRAM USER GUIDE LUBEWATCH CHEVRON SERVICES CAN HELP YOU RUN BETTER LONGER

1) READ THE M500 INSTRUCTIONS CAREFULLY TO GET A FULL UNDERSTANDING OF THE M500 AND HOW IT OPERATES.

3 & 4-Way Rotary Valves

Katharometer Power Supply Units

3/15/2017. Oil Analysis: When the Oil Speaks, You Should Listen! Oil Analysis. Common Wear Metals Found in Oil. Common Wear Metals Found in Oil

Batteries & Fuel Cells Seminar

Transcription:

ION EXCHANGE (I) LTD INDUSTRIAL CHEMICAL DIVISION

WATER QUALITY PRODUCTS

You can t manage what you can t measure. The importance of measurement is very well recognized by the industry. However, lack of vital resources like space, skill and fund often come in the way. Being in the field of water treatment for decades, we perfectly understand clients need. As always, ION EXCHANGE INDIA LTD., have come up with the right solution

WHY Simple and user-friendly On-the-spot results at the shop floor Does not require laboratory set up Quick result, timely action All vital parameters covered Economical, low cost per test Can be used by semi-skilled persons All India distribution and service network

RELIABILITY Validated by three qualified chemists Validated on three instruments Certified by independent labs Human error factor accounted Superior quality standard Quality Assurance Policy in force Reagent s Shelf Life of one year

KIT RANGE ph - 4.5-9.0 BX SILICA - 0.25 BX HARDNESS - 500 BX SILICA - 3 BX CALCIUM - 250 BX SILICA - 80 BX ALKALINITY - 200 BX SILICA - 200 BX ALKALINITY - 1000 BX PHOSPHATE - 10 BX CHLORIDE - 1000 BX PHOSPHATE - 50 BX FLUORIDE - 2.5 BX FRC - 4 BX IRON - 3.5 BX ClO 2-2 BX ZINC - 5 BX BROMINE - 2 BX COPPER - 0.5 BX HYPOCHLORITE - 12.5 BX SULFITE - 100 BX NITRITE - 250 BX DEHA - 0.35 BX NITRITE - 2500 BX HYDRAZINE - 0.3 BX NITRATE - 100 BX

ph 4.5 9.0 BX Parameter: Method: ph Color Chart Range: 4.5 9.0 Gradation: 4.5-5.0-5.5-6.0-6.5-7.0-7.5-8.0-8.5-9.0 Test per kit: 200 Application: DW/BFW/Steam Condensate/CW/RO/WW

ph Color Chart KIT ph - 4.5-9.0 BX COLOUR COMPARATOR (in ppm) 4.5 5.0 5.5 6.0 6.5 Image 9.0 8.5 8.0 7.5 7.0

HARDNESS 500 BX Parameter: Method: Total Hardness Drop Count Unit: ppm as CaCO 3 Range: 0 50/ 50 250/ 100 500 Test per kit: 200 Application: SW/DW/BFW/CW/RO

CALCIUM 250 BX Parameter: Method: Calcium Hardness Drop Count Unit: ppm as CaCO 3 Range: 0 50 / 50 250 Test per kit: 200 Application: SW/BFW/CW/RO

ALKALINITY 200 BX Parameter: Method: T & P Alkalinity Drop Count Unit: ppm as CaCO 3 Range: 0 200 Test per kit: 100 Application: DW/BFW/BW/CW/RO/WW

ALKALINITY 1000 BX Parameter: Method: T & P Alkalinity Drop Count Unit: ppm as CaCO 3 Range: 100 1000 Test per kit: 100 Application: DW/BW/CW/RO/WW

CHLORIDE 1000 BX Parameter: Chloride Method: Drop Count Unit: ppm as Cl Range: 100 1000 / 200 2000 Test per kit: 200 Application: BFW/BW/CW/RO

FLUORIDE 2.5 BX Parameter: Fluoride Method: Color Chart Unit: ppm as F Range: 0.0 2.5 Test per kit: 150 Application: DW

IRON 3.5 BX Parameter: Iron Method: Color Chart Unit: ppm as Fe Range: 0.1 3.5 Test per kit: 100 Application: BFW/BW/CW/RO/DW

ZINC 5 BX Parameter: Zinc Method: Color Chart Unit: ppm as Zn Range: 0 5.0 Test per kit: 200 Application: DW/CW/RO/WW

COPPER 0.50 BX Parameter: Copper Method: Color Chart Unit: ppm as Cu Range: 0.00 0.50 Test per kit: 200 Application: DW/BFW/Steam Condensate/CW/RO/WW

SULFITE 100 BX Parameter: Method: Sulfite Drop Count Unit: ppm as SO 3 Range: 0 100 Test per kit: 100 Application: BW

DEHA 0.35 BX Parameter: Deha Method: Color Chart Unit: ppb as DEHA Range: 0 350 Test per kit: 100 Application: BFW/Steam Condensate/BW

HYDRAZINE 0.3 BX Parameter: Method: Hydrazine Color Chart Unit: ppm as N 2 H 2 Range: 0.0 0.30 ppm Test per kit: 120 Application: BFW/BW

SILICA 0.25 BX Parameter: Silica Method: Color Chart Unit: ppb as Si Range: 0 250 ppb Test per kit: 200 Application: DM-MBW/BFW/ Steam Condensate

SILICA 3 BX Parameter: Method: Silica Color Chart Unit: ppm as SiO 2 Range: 0.1 3.0 Test per kit: 200 Application: BW/RO

SILICA 80 BX Parameter: Method: Silica Color Chart Unit: ppm as SiO 2 Range: 0 80 Test per kit: 50 Application: BW/CW/RO

SILICA 200 BX Parameter: Method: Silica Color Chart Unit: ppm as SiO 2 Range: 0 200 Test per kit: 50 Application: CW

PHOSPHATE 10 BX Parameter: Method: Orthophosphate Color Chart Unit: ppm as PO 4 Range: 0 10 Test per kit: 100 Application: BW/CW/RO/WW

PHOSPHATE 50 BX Parameter: Method: Orthophosphate Color Chart Unit: ppm as PO 4 Range: 0 50 Test per kit: 80 Application: BW/RO/WW

FRC 4 BX Parameter: Method: Free Residual Chlorine Drop Count Unit: ppm as Cl 2 Range: 0.1 4.0 ppm Test per kit: 200 Application: DW/CW/RO-Pretreatment

CHLORINE DIOXIDE 5 BX Parameter: Method: Chlorine Dioxide Drop Count Unit: ppm as ClO 2 Range: 0.5 5.0 Test per kit: 200 Application: CW/WW

BROMINE 5 BX Parameter: Method: Bromine Drop Count Unit: ppm as Br 2 Range: 0.5 5.0 Test per kit: 300 Application: CW

HYPOCHLORITE 12.5 BX Parameter: Method: Chlorine Dioxide Drop Count Unit: % as Cl 2 Range: 0.5 12.5 Test per kit: 100 Application: Hypochlorite Solution

NITRITE 250 BX Parameter: Method: Nitrite Drop Count Unit: ppm as NO 2 Range: 10 250 Test per kit: 200 Application: CW

NITRITE 2500 BX Parameter: Method: Nitrite Drop Count Unit: ppm as NO 2 Range: 100 2500 Test per kit: 200 Application: Closed Cooling Water System

NITRATE 100 BX Parameter: Method: Nitrate Color Chart Unit: ppm as NO 3 Range: 0 100 Test per kit: 100 Application: DW/Closed Cooling Water System

WATER POTABILITY TESTKIT

WATER POTABILITY TESTKIT Parameter Range ph 6.0 9.0 Alkalinity 0 800 ppm Chloride 0 1200 ppm Hardness 0 800 ppm Chlorine 0.1 2.0 ppm Iron 0.1 1.5 ppm Fluoride 0.0 2.5 ppm Nitrate 10 100 ppm

HIGHLIGHTS WATER POTABILITY TESTKIT All vital parameters are covered As per WHO/BIS standards Can be used at home/office Huge requirement in PHEDs Certified by Reputed Laboratory Economically packaged

WATER POTABILITY TESTKIT Parameter Range ph 4.5 9.0 Alkalinity 0 1000 ppm Chloride 100 2000 ppm Hardness 0 500 ppm Chlorine 0.1 4.0 ppm Iron 0.1 1.5 ppm Hypochlorite 0.0 12.5 % Silica 0 80 ppm Ideally suited for RO Plants

TESTKIT FOR BOILER & COOLING TOWER

TESTKIT FOR BOILER Parameter Range ph 4.5-9.0 & 10-12 P & M Alkalinity 0 1000 ppm Total Hardness 0 500 ppm Phosphate 0-10 & 0-50 ppm Silica 0.01 0.25 & 0 3 ppm Sulfite 0 100 ppm Hydrazine 0 0.3 ppm Iron 0 3.5 ppm Ideally suited for LP and MP boilers