INSTALLATION INSTRUCTION Oculux 3.5" Architectural Downlight R3CRN-11, R3CSN-11

Similar documents
INSTALLATION INSTRUCTION Aether 2 Shallow Recessed Housing

INSTALLATION INSTRUCTION Aether 3.5 Color Tunable LED Downlight

INSTALLATION INSTRUCTION

INSTALLATION INSTRUCTION

INSTALLATION INSTRUCTION Bollard Light 12V

INSTALLATION INSTRUCTION Bliss - Vanities & Wall Sconces WS-79622

INSTALLATION INSTRUCTION Vanities & Wall Sconce WS-85618

INSTALLATION INSTRUCTIONS SUPERPLANE 2.5. Suspended. A nd Avenue, Unit 1 Oakland, CA P E W alwusa.

INSTALLATION INSTRUCTIONS LIGHTPLANE 3.5. LP3.5 Suspended LED. A nd Avenue, Unit 1. CA P E W alwusa.

MOONRING 1.5 MOONRING 3

INSTALLATION INSTRUCTIONS MOONRING 1 LP1/MR1

Installation Instructions MX LED Enhanced Color Adjustable

D3 INSTALLATION GUIDE

IMPORTANT SAFEGUARDS When using electrical equipment, basic safety precautions should always be followed including the following:

INSTALLATION INSTRUCTIONS LED RETROFIT ASSEMBLY (LRA) Rev F

Ivalo Finiré 3 LED Recessed Lighting Installation Instructions

OSQ Series IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE. LED Area Light TO INSTALL:

NIOB-2 2" BWF IOLITE TRIMS

Installation Instructions 4 Gravity Enhanced Color Adjustable

Installation Instructions Sero / Qub Pendant RETROFIT CONSTRUCTION- INACCESSIBLE CEILING Mounting Option GP

90+ CRI 95+ CRI 95+ CRI 95+ CRI 90+ CRI 95+ CRI

Lumination TM LED Luminaires LAL Series - Continuous Run Option

Round or Square Type Non-IC Adjustable Housing with Toroidal Transformer for Flangeless Trims E3_L_-HANM_ 1.7

NIO-4RTL / NIO-4STL 4" Iolite Trimless Reflectors (New Construction only)

Spun Bay Installation Standard Version (non dimmable), Hook Mount

Albeo TM LED Luminaire Heavy Industrial High Bay Lighting (ABR1-Series)

READ AND FOLLOW ALL SAFETY INSTRUCTIONS 1. DANGER RISK OF SHOCK DISCONNECT POWER BEFORE INSTALLATION

Lumination TM LED Luminaire RC/LRC/RX/LRX Series - New Construction Frame

HR-led418-n Invisible Trim

Installation Guide DO NOT CUT WIRES

95+ CRI 90+ CRI 95+ CRI. Product Watts Color Temp CRI Version Driver Optional. 3G 3rd Gen

MAXLITE RKT LED Retrofit Kit

QUICK START INSTALLATION GUIDE ANALOG - INTELLIGENT POWER CENTER (IPC)

INSTALLATION INSTRUCTIONS

Wet Rated Batten LED Luminaire

Round or Square Chicago Plenum Hi-lume Wall Wash Housing with LED Lamp for Flanged Trims E3_F_-L_WC-HL 1.0

Finiré Prime. LED Recessed Downlights 13 / 14 W LED Round Adjustable Downlights 13 / 14 W LED Square Adjustable Downlights LUMINAIRE IMAGES

EMERY SKY SUSPENDED LED LUMINAIRE

BYOM ELEMENT SPECIFICATIONS BUILD-YOUR-OWN MULTIPLES

INSTALLATION INSTRUCTION Accent - Color Changing

NRM2-511 / NRM2-512 / NRM2-518

Captivate Illuminated Mirror Light

Round or Square Type Low-Profile Housing with Toroidal Transformer for Flangeless Trims E3_LF-HDSM-WR_ 1.0

MULTIPLES SPECIFICATIONS 1 X 1 OPEN

LS1 SERIES IMPORTANT: READ ALL INSTRUCTIONS THOROUGHLY AND CAREFULLY PRIOR TO INSTALLATION OF LINEAR SERIES FIXTURES AND RETAIN FOR FUTURE REFERENCE.

Project: Type: USA/CAN LOUVER FINISH AP91 F - / - -

3" LED SPECIFICATIONS ULTRA SHALLOW FIXED DOWNLIGHT

Lumination TM LED Luminaires Suspended LED Fixture (Series EP14)

Installation Instructions MX LED Downlight Remodel

Downlighting. LyteCaster. Complete product = Frame-in kit + Light engine + Trim Order each separately. 3" Accent round adjustable 800 Lumens

I. Pendant Mount Installation

Downlighting. LyteCaster. Complete product = Frame-in kit + Light engine + Trim Order each separately. 3" Accent round adjustable 800 Lumens

Catalog # Project. Comments. Prepared by

Essenza. Dim-To-Warm Round Downlights

UV8 & UV90 SERIES INSTALLATION INSTRUCTIONS

PAGE 1/9. Lumileds Luxeon CoB 1205, delivers a lumen maintenance greater than 70% after 50,000 hours of operation (L 70

LUNERA VERTICAL E26 LED FLOODLIGHT LED Replacement for E26 Medium Base Floodlights Type B Ballast Bypassed

WARNING / AVERTISSEMENT

1 Eco-Downlight IC Air-Tight Adjustable New Construction Housing Round or Square

Cylindrix III. Recessed Multiples

GETTING STARTED WITH IN-WALL DIMMER SWITCH

INSTALLATION INSTRUCTIONS LED Canopy Retrofit Kit

Downlighting. LyteCaster. Complete product = Frame-in kit + Light engine + Trim Order each separately. 3" Accent square downlight 800 Lumens

INSTALLATION & MAINTENANCE MANUAL HBL

ALL700/ALL700-CM INSTALLATION INSTRUCTIONS

LumeLEX 2084 SERIES INSTALLATION INSTRUCTIONS THIS SHEET CONTAINS IMPORTANT SAFETY INSTRUCTIONS. SAVE THESE INSTRUCTIONS.

Modul-Aim TM. Modular Base Unit (Patent Pending) SPECIFICATION SHEET PAGE 1/14 MOD1 DESCRIPTION SPECIFICATIONS

Project. Comments. Prepared by

Installation Instructions CRAFT M/L

PRIME PRIME 4 LED ARCHITECTURAL ROUND FLANGED DOWNLIGHT

LAD8R - Remodel 8 LED Architectural Downlight

LAD6R - Remodel 6 LED Architectural Downlight

Cylindrix III. Recessed Multiples

Catalog # Project. Comments. Prepared by

PROJECT INFORMATION PROJECT

Reflectors are compatible with respective Marquise II series housings manufactured by Nora Lighting.

Install Guide PMX SERIES PENDANT MOUNTED MATRIX SP1 STYLE

MXG2DSTL 3.5 MX G2 LED Square Trimless Lensed Downlight - Wet Location

ALL W INSTALLATION INSTRUCTIONS

LAD6 6 LED Architectural Downlight

RSA-MRZ Installation Instructions

MXG2DSTL 3.5 MX G2 LED Square Trimless Downlight

RSA-MRZ Installation Instructions

LAD8 8 LED Architectural Downlight

2" LED SPECIFICATIONS ADJUSTABLE DOWNLIGHT & WALL WASH

Outdoor Installation Using an Electronic LED Power Supply (TE-60L-12)

INSTRUCTION BOOK FOR. Tensioned Dual Masking Electrol

MULTIPLES SPECIFICATIONS 1 X 2 TRIMMED

LAD4 4 LED Architectural Downlight

Lumination TM LED Luminaire (IS Series)

LCD4 4 LED Commercial Downlight

LCD8 8 LED Commercial Downlight

LCD6 6 LED Commercial Downlight

MULTI-SPOT 1000/2000/3000 LUMEN LED

ASSEMBLY AND INSTALLATION INSTRUCTIONS

Luminaire characteristics: Source: Lumen maintenance: Optics: Material: Mounting: Electrical: Dimming: Finish: Weight: Warranty: Ratings:

STUDIO. Luminaire characteristics: Power input: 12.5W to 49W Lumens: 1300 to 4600lm (for 3000K, 80CRI) Luminaire efficacy: Up to 107lm/W.

Remodeler. Complete product = Frame-in kit + Adjustable light engine / Trim Order each separately

MULTIPLES SPECIFICATIONS 1 X 4 TRIMMED

4" LED SPECIFICATIONS LOW-PROFILE ADJUSTABLE DOWNLIGHT

Transcription:

. INSTALLATION INSTRUCTION SAFETY INSTRUCTION IMPORTANT: NEVER attempt any work without shutting off the electricity. Read all instructions before installing. System is intended for installation by a qualified electrician in accordance with the National Electrical Code and local regulations. Go to the main fuse box, or circuit breaker. Place the main power switch in the OFF position and unscrew the fuse(s) or switch OFF the circuit breaker switch(es) that control the power to the fixture or room that you are working on. Place the wall switch in the OFF position. AVERTISSEMENT IMPORTANT : Coupez l électricité avant TOUTE manipulation. Lisez toutes les instructions avant d installer. Système est destiné à être installé par un électricien qualifié en conformité avec le code national de l électricité et les règlements locaux. Accédez au panneau central de disjoncteurs ou de fusibles de votre demeure et placez l interrupteur principal en position d arrêt («OFF»). Placez l interrupteur mural en position d arrêt («OFF»). CAUTION: All parts must be used as indicated in these instructions. Do not substitute any parts, leave parts out, or use any parts that are worn out or broken. Failure to follow this instruction could invalidate the UL/cUL listing of this fixture. OVERVIEW: Housing is new construction Airtight IC. Housing requires a trim for a finished look. Refer to specification sheets for compatible trim options. OVERALL HOUSING DIMENSIONS SPECIFICATIONS Input: 120~277V;50/60Hz Installation: IC Dimming: ELV / TRIAC / 0~10V 1

HOUSING INSTALLATION: 1. Install housing using two hanger bars (24½ max). Bars are notched on the ends to fit over T bars in suspended ceilings (See FIG. 2A). FIG 1 Fixture Housing Screw 2. Hanger bars include a captive mounting screw-nail for ease of installation (See FIG. 1). Align the bottom of the hanger bar with the bottom of the wood joist. Secure the screw-nail on each end by screwdriver (See FIG. 2B), or by hammer (See FIG. 2C). 3. Slide fixture housing along bar hangers into desired location. Use locking screws to secure (See FIG. 2D). Joist Adjustable Collar Hanger Bar 4. To shorten hanger bars to fit in a 12 joist, snap off one section of the hanger bars (See FIG. 3). FIG 2 5. Remove spring latched fixture junction box door and connect fixture wires to building wires: Insert each supply wire into appropriate junction box wire connector. This fixture features electronic low voltage (ELV) or TRIAC or 0-10V dimming capabilities (See FIG. 4). To utilize ELV or TRIAC, wire black (line hot), white (line neutral) and green (ground) in accordance to dimmer specifications. To utilize 0-10V dimming, wire purple (dim+), gray (dim-), black (line hot), white (line neutral) and green (ground) in accordance to dimmer specifications. When not using a dimmer, connect black fixture wire to hot, white fixture wire to neutral and green fixture wire to ground. Leave all other wires capped individually. FIG 3 6. Place all wiring and connectors back in junction box and replace the junction box s cover. Snap off one section fit in a 12" joist FIG 4 Black - Hot Green - Ground White - Neutral Violet - Dim + Gray - Dim - 2

7. For the square housing, rotate the collar frame as necessary should additional adjusting be needed for field alignment. (See FIG. 5). FIG 5 8. Cut a Φ44 or 44 44 hole in the ceiling at the point of installation and install ceiling (See FIG. 6). 9. To account for ceiling thickness, adjust the depth of the adjustable collar using an allen wrench(see FIG. 7) until button of adjustable collar is in flush with the ceiling surface. FIG 6 FIG 7 Cut Out: Round: ø 4 1/4" Square: 4 1/4" x 4 1/4" For trimless installations, follow Steps 10-11. Trimmed Installation go to Step 12. 10. Secure the trimless frame to the housing using the four screws provided (See FIG. 8.) FIG 8 Square Trimless Round Trimless 3

11. Insert the plaster shield into opening of housing. Apply plaster or spackle over trimless front and sand surface when dry for finished look. Remove plaster shield when finishing is complete. (See Fig. 9-10) FIG 9 FIG 10 12. Prior to installing the light engine into housing, adjust fixture to desired beam angle. Light engine comes factory installed with narrow flood optical film. To adjust to flood, replace "N" optical film with "F" optical film. For spot and wall wash beams, remove all films. Films install behind optical holder and in front of lens, the glossy side facing outward. (See Fig. 11-12). Add accessories if desired behind optical holder. Refer to spec sheet for compatible accessories. FIG 11 FIG 12 Light Engine Lens Film Optic Holder 4

13. Connect the light engine to the housing using the power connector. Insert the light engine into the housing until it is secured by two spring clips on each side (See FIG. 13). FIG 13 14. For aiming of adjustable or wall wash fixtures: Push the side of the light engine using your hand to increase the tilt angle of the light engine (See FIG. 14). To decrease the tilt angle, insert a screwdriver into the opening on the side of the light engine and pull the light engine into the desired position (See FIG. 15). NOTE: For a standard wall wash angle, please align the clip with the W symbol on the light engine (See FIG. 16). Power Connector FIG 14 FIG 15 FIG 16 Wall Wash Location 15. Refer to installation instructions for appropriate trims to complete the instillation. 5

Light Engine Replacement: 1. To remove the light engine from the housing, use a flathead screwdriver to press down on the spring clips on each side until the light engine is released (See FIG. 17). FIG 17 Driver Replacement: 1. To replace the driver, unscrew the wingnuts on the inside the housing. Remove the cover over the driver and replace the driver before securing back into its original position (See FIG. 18). To allow for more space when working in the housing, remove the adjustable collar by unscrewing 4 screws. FIG 18 6