Relays 505 V 40/30A 509 4V 40A 50074 V 40/30A 50 Socket for 505 and 509 Resistors 5036 V (0.4 +0.4 ) 300 F (50 C) meltfuse 5056 4V (.8 +.0 ) 5055 4V (0.8 +.8 ) 500 V (0.5 +.3 ) 5039 V (0.35 +.5 ) 50095 V (0.5 +0.5 + ) 50090 4V (.4 +4.5 ) 5060 5060 50604 9030 V (0.4 +.5 ) ceramic 333 F (67 C) meltfuse 4V (. +3.5 ) ceramic 333 F (67 C) meltfuse 4V (0.8 +.8 ) Resistor bracket for ceramic resistor Used with blower #55 (not pictured) Diodes 50097 Heavy duty type, amp, 03 thread Automatic Circuit Breakers 5006 50406 504 5044 V, 30 amp, /4 male terminal (Not pictured) 4V, 0 amp,03 thread 4V, amp,03 thread V, 40 amp,03 thread Junction Block 50006 03 thread brass studs, rated 30A, 600V. Max 30 F (50 C) Mobile Climate Control 39 MCC Reference Manual 04
Pressure Switches Pressure switches safeguard the compressor against extreme high and low pressures. This occurs when condenser capacity is reduced or after a loss of refrigerant. Recommended to be installed on the receiverdriers. They can also be installed on special fitting with switch port. 50038 R Male 3/8 4 50058 R Male 3/8 4 50308 R34a Male 3/8 4 50667 R34a Male 3/8 4 50343 R34a Fe 7/6 0 fits schrader valves 50674 R34a Fe 7/6 0 fits schrader valves Cut Out Pressure Settings Psig (MPa) Part High Medium Low 50038 50058 50308 50667 50343 50674 370 (.6) 370 (.6) 3 (.5) 8 (.6) 8 (.6) 7 (0.) 7 (0.) Rotary Switches 5009 For 3 speed motors, 5 amp, 4 pos 50044 For 3 speed motors, 5 amp, 4 pos 50305 For speed motors, 5 amp, 3 pos 50307 On/off, 5 amp, pos Rotary switches include 50066 nut. Switches 5009/44/8 include an A/C circuit that closes when in low, medium or high speed 50034 Connector for 5009/44 5008 For 3 speed motors, 5 amp with resistor, 4 pos. Must be mounted in the air stream for cooling Toggle Switches 50536 Two positions 50537 Three positions 5000 For 3 speed motors, 5 amp, 4 pos Includes an A/C circuit that closes when in low medium or high speed. Mobile Climate Control 330 MCC Reference Manual 04
Thermostats All thermostats include nut 50066. Thermostats are used to prevent icing of the coil by cycling the compressor clutch. Temp settings are 6 F (3 C) cut out and 35 F ( C) cut in. Capillary tube to be insterted at the coldest area in the coil. It must be inserted with minimum 5% of the capillary tubes total length. 50030 50045 508 9 capillary tube 36 capillary tube As above with PVC tube protected capillary tube 50069 8003 4 capillary tube PVC tube /4 OD (Not pictured) (used to protect capillary tube, specify length when ordering) Stepless Blower Controller 9006 Blower Speed Kit A 3way Packard Weather Pack to Potentiometer Assy., an extension wire harness can be supplied for remote control panel installations. Length.7±0. (550±5) B way Packard Weather Pack to Blower Motor Terminals: (A) Battery A, (B) MotorB Mating Connector: MCC #3068, with terminal MCC #3039 Length 3±0. (585±.5) C 3way Packard Weather Pack to Power Input Terminals: (A) BatteryA, (B) GroundC (C) IgnitionG Mating Connector: MCC #309, with terminal MCC #3 06 Length 3±0. (585±5) No. Part No. Description 3 350033 5058 350036 Motor Stepless Control Knob Potentiometer Assy. Mobile Climate Control 33 MCC Reference Manual 04
Rotary Controls 60350 nut 50066 included 60345 nut 50066 included 60359 nut 50066 included Bowden Cables 60037 Stainless steel wire 60065 Specify length when ordering (Use this Bowden Cable with metal controls only.) Vinyl cover to be removed under cable clamp. Vinyl cover galvanized steel spring with plastic insert. Specify length when ordering. 9044 3/6 pushnut used for holding pigtails on shafts Injection Molded Rotary Control & Cable 60095 Medium duty injection molded rotary control, nut included. 60335 As above but with extended shaft (3mm) nut included. Sym Part No. Description Note A mm B mm A in B in 90040 Nut 7/6 0 60099 Bowden Cable With adjuster 00 50 8 88 60097 Bowden Cable With adjuster 00 50 46 49 60098 Bowden Cable W/O adjuster 00 50 8 88 60096 46 49 Bowden Cable W/O adjuster 00 50 Use these bowden cables with injection molded controls only Push & Pull Control 60008 Pull and push control for heavy duty use. A = 84 (4 mm) B = 90 (86 mm) 60058 60058 Longer version of above. A = 56 (396 mm) B = 6 (44 mm) Mobile Climate Control 33 MCC Reference Manual 04
Fuse Holder INLINE FUSE HOLDER 5068 Fuse holder (in Line) Little Fuse FHAC.75 50568 Fuse 3A Little Fuse ATO 7.5.8 50569 Fuse 5A Little Fuse ATO 7.5.8 50683 Fuse 7.5A Little Fuse ATO 7.5.8 50684 Fuse 0A Little Fuse ATO 0.8 50685 Fuse 5A Little Fuse ATO 5.8 50686 Fuse 0A Little Fuse ATO 0.8 50687 Fuse 5A Little Fuse ATO 5.8 50688 Fuse 30A Little Fuse ATO 30.8 50689 Fuse 40A Little Fuse ATO 40.8 Mobile Climate Control 333 MCC Reference Manual 04