W SERIES IMPULSE VOLTAGE TEST SYSTEM APPLICATION FEATURES

Similar documents
Impulse Voltage Test System, Q Structure, kV

HIGH VOLTAGE MODULE TEST SYSTEM

OPERATING INSTRUCTIONS ECON-M

KD LV Motor Protection Relay

SINAMICS GM150 IGCT version

Installation and Maintenance Instructions. World Leader in Modular Torque Limiters. PTM-4 Load Monitor

SEMIS Simulation Tool for 6 pulse Controlled Rectifier

RENEWABLE ENERGY TRAINER

Technical Data Sheets

INTER PLANT STANDARD STEEL INDUSTRY SPECIFICATION FOR STATIC EXCITATION CONVERTORS FOR SYNCHRONOUS MOTORS (FIRST REVISION)

OPERATING INSTRUCTIONS MCP-MT1

INTRODUCTION. The plug-in connection on the cables and lightning arrestors, allows for easy installation and replacement.

CENTAURI ENERGY SERVER TECHNICAL DATA kw POWER

List of major equipment in Electrical Enginerring Department Labs

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

RVS-DN Digital Reduced Voltage Motor Starter

ELECTRIC MACHINES EUROLAB 0.3 kw

OPERATING AND MAINTENANCE MANUAL. Primary Current Injection Test Set. 750ADM-H mk2

NEW ZEALAND POST OFFICE NEGATIVE 50V D.C. TO POSITIVE 50V D.C. SUPPLY NOTES PR 2157 ISSUE 1 APRIL 1977

Outdoor vacuum breaker for railway applications - FSK II

HV9000 High Voltage Modular Training Set

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

SF6 GAS INSULATED METAL ENCLOSED SWITCHGEAR (GIS)

Static frequency converter couples US paper mill s 25-Hz and 60-Hz electricity grids

HIGH POWER RECTIFIER SYSTEMS

RELIABLE SOLUTIONS in POWER ELECTRONICS. Power Management Instruments RDAT SERIES BATTERY CHARGER / DC RECTIFIER PMI / GESS / KARMET GROUP COMPANIES

Technical Data Sheets

Low and High Voltage Power Supplies

SINAMICS SM150. 4/2 Overview. 4/2 Benefits. 4/2 Design. 4/6 Function. 4/8 Selection and ordering data. 4/8 Options

SE-3SCR-LM MANUAL MOTOR LOAD MANAGER

Technical Data Sheets

Induction Power Supplies

KV4-300 mk2. KV5-200 mk2. KV5-100T mk2. KV3-250 mk2

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

Electronic Ballast EVG 2000-T

Ignition Coil Current Waveforms 2007 Honda Accord SE 4CYL

Voltage limiting device HVL

OPERATING INSTRUCTION: DGC-6D/6D1I

UNIVERSAL PUSHBUTTON DIMMER ETD 2 (Rail mount version)

HGM1780 AUTOMATIC GENERATOR MODULE CONTENT 1. SUMMARY PERFORMANCE AND CHARACTERISTICS SPECIFICATION OPERATION...

URM-00 TRAINING MODULE FOR INDUSTRIAL ELECTRIC MOTORS FOR MAIN DRIVE AND CONTROL CIRCUITS EDUCATIONAL KIT TO STUDY MOTORS CONTROL AND PROTECTION

Baker PPX Power Packs

UPS Wizard User s Manual

Guaranteed Technical Particulars(GTP) Deviation/Remarks Specify if any. Computerized Motor testing system suitable to test LV 3 phase motors

EPS/ELA-Series User Manual EPS/ELA 250W

Technical Data Sheets

Contact Details: Mail Id:

HIGH VOLTAGE SURGE ARRESTER SPECIFICATION

Voltage limiting device HVL

HGM1780. Automatic Genset Controller USER MANUAL. Smartgen Technology

INTER PLANT STANDARD - STEEL INDUSTRY THYRISTOR CONVERTORS FOR ARMATURE AND FIELD OF MAIN DRIVE MOTORS. Corresponding IS does not exist

ECU1000 ELECTRONIC CONTROL UNIT

ELECTRIC TRACTION.

Technical Data Sheets

Burden Fuse Rating Resistor SAF / SAK6 1NM 10mm M8 12NM SAF / SAK10 2NM 16mm M8 12NM

Small size High power

DISTRIBUTION SOLUTIONS. GSec Gas-insulated switching and isolating apparatus

SPREADER SYSTEM. Proportional three function. 1. Features and Specifications. User Manual 12 INPUTS 12 OUTPUTS CONNECTIVITY MAIN FEATURES

HV Compensation & Filtering Products

Exercise 6. Three-Phase AC Power Control EXERCISE OBJECTIVE DISCUSSION OUTLINE DISCUSSION. Introduction to three-phase ac power control

Analog Input Terminal

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

TECHNICAL DATA SHEET KVA UPS Systemss

INTECH Micro 2300-RTD6

Power System Solutions (PSS)

INSTRUCTION MANUAL FOR Revision C MODEL SERIAL NUMBER LAMBDA EMI 405 ESSEX ROAD, NEPTUNE, NJ 07753

Temperature Controller. TC5+2V4SA Plus USER'S MANUAL

Transforming Energy.. For Advanced Technology

ELECTRICAL MACHINES LAB.

GEISLINGER MONITORING

Descriptive Bulletin. R-MAG TM magnetically actuated dead tank outdoor vacuum circuit breaker 15.5 kv - 38 kv

A novel synthetic test system for thyristor level in the converter valve of HVDC power transmission

MCD 200 Series Soft Starters

Est Battery Data Logger BDL3000

Observe all necessary safety precautions when controlling the soft starter remotely. Alert personnel that machinery may start without warning.

MODEL 520 REMOTE START ENGINE MANAGEMENT SYSTEM

Uninterruptible Power System

TOWER MAXI T SINGLE CONVERSION ON LINE UPS SYSTEMS

String Monitoring and Control System for Solar Photo Voltaic Power Plants

USER MANUAL. 10KV Digital High Voltage Insulation Tester. Model MG500. Additional User Manual Translations available at

DPX moulded case circuit breakers

2.1 Warnings & Agency Approvals Electrical Connections - Specifications Standard Wiring Configurations...2 4

XM1 - Motor protection relay

Independent Testing Laboratory for High Voltage Equipment

R-MAG Vacuum Circuit Breaker with Magnetic Actuator Mechanism 15.5 kv - 27 kv; 1200 A A

Pretest Module 29 High Voltage Unit 1

SALES PRESENTATION FOR RELAYS, CONTACTORS & MOTOR STARTER TESTING EQUIPMENTS

Cat/DCG-6D1I/07-08/03/Ver 1 Page 2/10

Inlet Controller TC5-ITA USER'S MANUAL. M rev. 02 K rev. 00

SAVER DSP SERIES. 3-10kVA USER MANUAL

Innovative Testing Equipment. Series DF torque sensors

General Description. BADICHEQ 3000 (Battery Diagnostic & Charge Equalizing) The compact solution for perfect battery management

Using Apollo Solar Remote Monitoring Software

STARDEX 0303, 0304, 0305, 0306, 0402, STARDEX Master Ultima. STARDEX Dimas. STARDEX Dimas Ultima

IT8900 High Performance High Power Programmable DC Electronic Load

HGM1770 Automatic Generator Control Module OPERATING MANUAL Smartgen Electronic

PowerCommand 2100 digital generator set control

IC18DV/92/SCP - Multipurpose Distillation Plant with Automatic Control

SHOCK ABSORBER/DAMPER TESTING MACHINE

We reserve the right to alter data according to improvements made. Previous documents become invalid with the issue of this document.

Transcription:

W SERIES IMPULSE VOLTAGE TEST SYSTEM Impulse Voltage Test System is used to generate impulse voltages from 100 KV to 2400 KV simulating lightning strokes and switching surges with energies up to 240 KJ. The KVTEK make impulse voltage test systems are modular in construction, flexible and cover testing applications according to IEC, ANSI/IEEE and other national standards. The basic system can be upgraded in various ways to allow optimizing the impulse test system for tests on different high voltage equipments. The system operation is user friendly and incorporates all the necessary features of Impulse Voltage Test. APPLICATION The basic system is used to test any high voltage equipment like Power Transformers Distribution Transformers Cable (Type Tests) Surge Arresters (impulse current tests) Motor / Generators Insulators Bushings GIS Instrument Transformers Research & Development and Universities Low internal inductance Easy and quick reconfiguration to suit different testing needs User friendly operation through computer and microprocessor controlled hardware. Equipped with resistors for performing lightening full, lightening chopped and switching impulse tests on wide range of loads. Automatic grounding device and security grounding system (available as an option). Alarm annunciation to display all fault conditions. Filtered clear air constantly supplied through the sphere gaps while the system is running. Reliable and fail safe triggering circuitry.

STRUCTURE CHARACTERISTICS All the coupling sphere gaps are mounted in an insulated tube and every level of sphere gaps is equipped with spark observation panel. The capacitors are composed of oil immersion insulation and are small in volume & light in weight. The internal resistance of each capacitor is less than 0.2 µh. The waveform resistors are epoxy moulded and have noninductive winding. Spring loaded connections make them easy to be reconfigured. Damped voltage capacitor divider is composed of a noninductive modular structure. The low voltage arm is low inductance monolithic connection. The top is equipped with corona shield. MAIN COMPONENTS OF THE SYSTEM Impulse Generator Charging Rectifier Voltage Divider Chopping GAP IMPULSE GENERATOR Shunt Glaninger Circuit Control System Analyzing System Impulse Generator (WX-YIG) where X stands for voltage rating X KV and Y stands for energy rating Y KJ. The Impulse Voltage Generator consists of a number of capacitors, connected to spark gaps and series & parallel resistances, charged in parallel up to a maximum of 100 KV. After the set voltage is reached a trigger pulse initiates firing of the first spark gap. The resulting over voltage triggers successive stages thus connecting them in series and multiplying the charging voltage. This in the generation of required impulse. An impulse voltage divider reduces such impulse voltage to a safe level that the measuring instrument requires. Chopping sphere gaps connected in parallel with the Impulse generator may also be triggered through microprocessor control to obtain chopped lightning impulse of desired duration. CHARGING RECTIFIER D100-0.05 (100 kv, 50 ma) OR D100-0.15 DC (100 kv, 150 ma) Charging Power Supply comprises of: AC Test Transformer (50 kv), Voltage doubling circuit, Silicon rectifiers for AC-DC Conversion, Thyristorized Voltage Regulator, Remote controlled Polarity changing circuit, Resistive voltage divider of 100 kv, 200 M ohm and Automatic earthing switch is used for charging the stage capacitors. The DC Charging power supply is remotely controlled by WV23 computerized control unit. VOLTAGE DIVIDER IDE Series (upto 1000 kv LI) have external damped resistance. The damped-capacitive impulse voltage dividers can be used to measure full lightning impulse voltages, tail chopped impulse voltages, switching impulses and AC voltages. They meet all requirements of IEC 60060-2 (1994), in particular those with respect to measuring accuracy and step response. At the same time they can be used as a basic load for impulse voltage generators. IDI Series (Above 800 kv LI) have internally distributed damped resistance. The damped-capacitive impulse voltage dividers can be used to measure full lightning impulse voltages, tail chopped impulse voltages, switching impulses and AC voltages. They meet all requirements of IEC 60060-2 (1994),in particular those with respect to measuring accuracy and step response. Furthermore, all HV tests are carried out in accordance to the applicable IEC 60060-2 requirements (up to the limits imposed by our test system & premises). They can be used as a basic load for impulse voltage generators. CHOPPING GAP (MCG-X) where X stands for the voltage rating in KV. Multiple chopping gap is used to chop lightning impulses (on the front and on the tail) as well as switching impulses up to the highest voltages. The multiple chopping gap serves simultaneously as a load capacitor for the impulse generator and allows excellent reproducibility of the chopping time and does not distort the wave shape until the chopping point. The sphere distance is automatically adjusted by the WV23 controls. In the automatic mode, their distance is set automatically as a function of the charging voltage. The gap distance is displayed on the controller screen. The chopping is initiated by the first stage having a triggering plug triggered by electronic pulse. SHUNT Shunt is used in series with the test objects to measure the impulse current flowing through the object during the impulse test. They consist of a metal cylinder with coupling flanges and coaxial measuring connector.

GLANINGER CIRCUIT: (optional Accessory) The Glaninger Circuit can be used for testing very small inductances, such as low-voltage windings of transformers. The Glaninger inductance (LG) is connected in parallel to the generator serial resistor(rs). The rapid rise at the impulse front (high frequency components) is not influenced by the additional Glaninger inductance (LG), therefore the front of the impulse is mainly defined by the serial resistor (RS). Conversely, the slow decay (low frequency components) at the tail of the impulse is influenced by the parallel connection of LG and RS. The result is less damping in the overall test circuit and an increased time to half value. WV-23 COMPUTERIZED CONTROL UNIT WV 23 control unit communicates to the operator through an all in one computer installed with user friendly software. The system may be operated in Full Auto, Full Manual or Semi Automatic mode. In fully automatic made the operator feeds the desired charging voltage and the charging time. All other parameters like sphere gap, chopping gap triggering instant are taken care of by the controller. In manual mode all these parameters may be selectively chosen to operate in auto or manual mode. In Semi automatic mode is when some parameters operate in auto mode while others in manual mode. ON or HV OFF soft switch respectively. When we press HV ON or HV OFF soft switch the status bar indicates EARTHED or NOT EARTHED respectively. Auto/Manual mode selector soft switch, user can select the mode either auto or manual. Control Power key switch activates control circuits. This is designed to limit test system access to authorized personnel only. Indicator light has been provided to indicate its status. CI Indication on the laptop screen has been provided to indicate that the customer interlock is closed. The test system cannot be energized until this interlock is secured. Emergency Off mushroom type push-button, allows you to actuate the tripping of main circuit breaker thus removing the power to controller. This large push button latches when pressed. To release the latch, rotate the pushbutton clockwise. The push button must be released before the main circuit breaker can be reset to resume power into the controller. Metering HV voltage, current and sphere gap with adjustable scale, highly accurate and calibrated metering of the HV voltage, current and gap between spheres has been provided on the screen of laptop. The measured parameters can be traced to national or international standards. HV ON and HV OFF soft switch, allows you to switch ON or switch OFF the HV. Charging voltage and time, allows user to set the desired high voltage and desired charging time. User can set the charging time from 15 seconds to 120 seconds. Main Power circuit breaker, located in the voltage regulator cabinet provides the input power connection to the system. This breaker also serves as the primary overload protection device for the system. Switching ON/OFF High voltage Contactor through soft switch, we can switch ON or OFF the high voltage contractor through HV Polarity select soft switch, allows you to select either positive or negative polarity before pressing HV ON switch. After the desired polarity gets engaged, polarity ok indication on the controller is displayed. Trigger soft switch, allows you to manually trigger the generator in manual or semi automatic mode. In fully automatic mode the generator will be triggered automatically after it has reached the preset charging voltage level.

Ramp soft switches, allow you to ramp up the high voltage automatically in auto mode and manually through INC (increase) or DEC (decrease) soft switch manually. Sphere gap control soft switches, allow user to set the gap between spheres either in auto or manual mode. In manual mode, user has to adjust the gap between spheres through DEC. and INC soft switches. Three Alarms; indicates the No trigger, self trigger or static voltage difference, if any. No Trigger: When trigger button is pressed (Auto/Manual) but the generator does not trigger. Self Trigger: Trigger occurs without trigger button being pressed (Auto/Manual). Static Voltage Difference alarm is displayed on screen, when there is the voltage difference between actual voltage display on meter and the reference voltage. Alarm reset button allows you to reset the alarms. Hooter alarm soft switch is used for system ready warning and the hooter will sound automatically after desired charging voltage stabilizes and the generator is about to get fired. COMM. OPEN / COMM. CLOSE: If the communication cable from PC to the electronic controller is connected properly, COMM.OPEN message will be displayed on the screen otherwise it will display COMM.CLOSE. Earthed / Not Earthed: If the system is grounded, EARTHED message will be displayed on the screen otherwise NOT EARTHED will be displayed on status bar. System must be ungrounded before switch on the HV voltage and system must be grounded after completion of the test. Counter counts the number of triggers. In auto mode, the counter increments by one after every trigger. In manual mode operation, the user has to increment it manually by double clicking on the counter status bar. Counter has three soft switches: INC (+), DEC (-) and RESET (0). For increment press INC (+) soft switch, for decrement press DEC (-) soft switch or to reset the counter press RESET (0) soft switch. Warning lamp, will switch on, when user presses the HV ON soft switch and warning lamp will switch off when user presses the HV OFF soft switch. IM -212 DIGITAL IMPULSE ANALYSING SYSTEM Introduction IM-212 with user friendly software and powerful curve analyzing tools along with report generating templates offers a complete solution to modern testing needs. Complete impulse capturing of IM-212 enables to determine the detailed information about the test object faster and accurately. Measurement evaluation and analysis of impulse voltages and currents can be performed according to IEC 61083, IEC 60060, IEC 60076, IEC 60099, and IEC 60230, the relevant standards for High Voltage Impulse Testing. 12 bit vertical resolution AT 100 MS/sec. Automatic evaluation of all common impulse parameters Software features like difference & comparison of curves. FFT curve, user defined Smoothing of curve and may more. Fulfils IEC 61083-1 & IEC 61083-2 standards. Customized test report generation. User friendly & interactive graphical user interface.

MEASUREMENT AND ANALYZING User can save the Testing Parameters for different Test Objects as files, which can be retrieved any time. Display can be toggled between Time Domain and Frequency Domain with a click. Two independent Channels are available for voltage and current measurement. Logarithmic or Linear scales can be selected in Frequency Domain analysis (FFT). Real Curve and mean Curve may be viewed individually or together. Mean curve if calculated from user selected Smoothness Filter Factor. Graph Marking Grid can be turned ON / OFF as per requirement for better viewing / evaluation. Data Points corresponding to 10%, 50%, 90% and 100% may be displayed or hidden. Any two measurements for the database may be compared using the difference function. Memory Depth is automatically set by the system depending on the measuring time Automatic and Manual mode for saving Impulse curves. Single or Multiple Acquiring Mode with process Status Display. Report Generation may be set to print 1, 2, 4 or 8 curves per sheet and also save it as PDF file. Horizontal and/or Vertical zooming to view details on any section of the curves. Counter facility is available; counter is incremented automatically on every impulse. It can be reset anytime. History Stack to view last 25 non-saved measurements. Wave parameters like Upk, T1, TC etc are displayed along with the curve. TECHNICAL SPECIFICATIONS System Hardware CPU Pentium Duo Core Monitor Desktop TFT 19' Memory 2 GB RAM & 80 GB HD (Or better configuration) Impulse Voltage : Standard lightning wave: Wave Parameter 1.2 µs ±30% / 50 µs ±20% Standard switching wave: 250 µs ±20% / 2500 µs ±60% Lowest Voltage Output: Charging Voltage Instability Percentage: < ± 1% Trigger Range: 1% - 100% Impulse Duty Cycle: 10 % of Rated Voltage > 70% of Rated Voltage.- Intermittent < 70% of Rated Voltage.- Continuous Generator Efficiency: Lightening wave (no load) >85% Switching wave (with the load of 3000pF)>70% Chopping Time: 2 6 µs Chopping Time Resolution: 0.1 µs ANALYZING SYSTEM Input Signal Number of Channels Connections Input voltage Input Range Selection Over Voltage Protection Input Impedance Analog Bandwidth Triggering Data Acquisition Resolution Sampling Rate Measuring Time Accuracy Operating Conditions Supply Voltage Temperature Range Two (Independent) LEMO 75 Ohms 2 V to 1900 Vpp Automatic (According to BIL set By user) 2 KV 2 MOhm, 20 pf 50 MHz for each channel Internal. Ch1 or Ch2 selectable 12 Bit Relative Humidity < 95% 100 MS/s max. 1 to 9999 usec, continuously Settable +/- 1% for Upeak,T1,T2 and Tc 230 V AC ± 10%, 50 Hz/ 110 V AC ± 10%, 60 Hz 5 50 degree C 284, Sector-8, IMT Manesar, Gurgaon - 122050 Haryana, (INDIA) Ph.: +91 124 3226856, Fax: +91 124 4971301 E-mail : sales@kvetk.in Web : www.kvtek.in