MOONRING 1.5 MOONRING 3

Similar documents
INSTALLATION INSTRUCTIONS MOONRING 1 LP1/MR1

INSTALLATION INSTRUCTIONS LIGHTPLANE 3.5. LP3.5 Suspended LED. A nd Avenue, Unit 1. CA P E W alwusa.

INSTALLATION INSTRUCTIONS SUPERPLANE 2.5. Suspended. A nd Avenue, Unit 1 Oakland, CA P E W alwusa.

INSTALLATION INSTRUCTION Aether 3.5 Color Tunable LED Downlight

INSTALLATION INSTRUCTION Aether 2 Shallow Recessed Housing

INSTALLATION INSTRUCTIONS LED RETROFIT ASSEMBLY (LRA) Rev F

IMPORTANT SAFEGUARDS When using electrical equipment, basic safety precautions should always be followed including the following:

INSTALLATION INSTRUCTIONS LED Canopy Retrofit Kit

READ AND FOLLOW ALL SAFETY INSTRUCTIONS 1. DANGER RISK OF SHOCK DISCONNECT POWER BEFORE INSTALLATION

Lumination TM LED Luminaires Suspended LED Fixture (Series EP14)

INSTALLATION INSTRUCTION Oculux 3.5" Architectural Downlight R3CRN-11, R3CSN-11

INSTALLATION INSTRUCTIONS

Spun Bay Installation Standard Version (non dimmable), Hook Mount

OSQ Series IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE. LED Area Light TO INSTALL:

Albeo TM LED Luminaire Heavy Industrial High Bay Lighting (ABR1-Series)

Lumination TM LED Luminaire RC/LRC/RX/LRX Series - New Construction Frame

Lumination TM LED Luminaires LAL Series - Continuous Run Option

EMERY SKY SUSPENDED LED LUMINAIRE

Captivate Illuminated Mirror Light

INSTALLATION INSTRUCTION Bollard Light 12V

LS1 SERIES IMPORTANT: READ ALL INSTRUCTIONS THOROUGHLY AND CAREFULLY PRIOR TO INSTALLATION OF LINEAR SERIES FIXTURES AND RETAIN FOR FUTURE REFERENCE.

LUNERA VERTICAL E26 LED FLOODLIGHT LED Replacement for E26 Medium Base Floodlights Type B Ballast Bypassed

Wet Rated Batten LED Luminaire

Customer service: or Upper mounting ring. Canopy

GETTING STARTED WITH IN-WALL DIMMER SWITCH

Specification Grade Contemporary Wall Mount/Technical Installation Data

MAXLITE RKT LED Retrofit Kit

INSTALLATION INSTRUCTION

Tetra minimax. LED Lighting System. BEFORE YOU BEGIN Read these instructions completely and carefully. Installation Guide

Installation Instructions Sero / Qub Pendant RETROFIT CONSTRUCTION- INACCESSIBLE CEILING Mounting Option GP

ELV1abbccd-e. Color Temperature: 30 = 3000K White 35 = 3500K White 40 = 4000K White 45 = 4500K White 50 = 5000K White

LAL SERIES LED LUMINAIRE

INSTALLATION INSTRUCTION Bliss - Vanities & Wall Sconces WS-79622

INSTALLATION INSTRUCTION

Installation Instructions

The only lighting product that is designed, approved, and patented to replace the cross members in a suspended grid ceiling system.

960 Montage sur staff préfabriqué Mounting in prefabricated plaster

Installation Instructions CRAFT M/L

MEDIA LED. Pendant Standard Mount Installation ou de montage WARNING:

ALL700/ALL700-CM INSTALLATION INSTRUCTIONS

WARNING / AVERTISSEMENT

INSTALLATION GUIDE FOR VM-3000 SERIES INTEGRATED VOICE EVACUATION SYSTEM

CES MOUNT SMS MOUNT EAS MOUNT PNS MOUNT LOUVER OPTION 2700K 3000K 3500K 4000K STATIC GREEN STATIC RED STATIC AMBER WHITE (4000K) - 48" FIXTURE

INSTALLATION INSTRUCTION Vanities & Wall Sconce WS-85618

I. Pendant Mount Installation

CES MOUNT SMS MOUNT EAS MOUNT PNS MOUNT LOUVER OPTION 2700K 3000K 3500K 4000K STATIC GREEN STATIC RED STATIC AMBER WHITE (4000K) - 48" FIXTURE

Have a Bright Day! Nicholas Harmon President, Verilux, Inc.

SAVE THESE INSTRUCTIONS

WARNING/AVERTISSEMENT. Coupez l alimentation électrique à la boîte de fusibles ou au disjoncteur avant servicing or installing product.

Installation Instructions

LST Solid-State Starter User s Manual TB WOOD S INCORPORATED

Lumination TM LED Luminaire (IS Series)

97Ti, 95Ti, 93T Treadmills Assembly Instructions

Installation Instructions

LED Garage Light INSTALLATION INSTRUCTIONS. *Model number noted on carton label

Cable Cubby 1202 and 1402 Installation Guide

Elle Surface Mounting Instructions

MODELS. 2 & 4 Low Profile Linears

ALL W INSTALLATION INSTRUCTIONS

INSTALLATION GUIDE Works in double and single ended wiring.

OmniAire Omnitec Design, Manufacturing Air Purification Equipment Since 1988

MODELS 2 & 4 Top Conduit Linears

(SB2) (SB1) (SB3) (SB5) (SB4) Cylindrical Installation Instructions. A. CHECKLIST (4 each AA Batteries Included) (SB1) (SB4) (SB2) (SB6) (SB6) (SB3)

ASSEMBLY AND INSTALLATION INSTRUCTIONS

Horticulture Batten LED Luminaire

HP-2 / HP-6 Direct Installation Instructions Overview

MONORAIL KITS INSTALLATION INSTRUCTIONS SPOTS

QTM-eLED INSTALLATION INSTRUCTIONS Must be installed by licensed electrician.

SloanLED THINLED. Constant Current. Installation Guide

INSTALLATION INSTRUCTION Magnetic Transformer

MOONRING ELLIPSES MR1.5/MR3-E SUSPENDED, CEILING. STANDARD SIZES 1.5" or 3" Aperture Ellipse sizes from 5' (60"x30") to 12' (144"x72")

Elle Surface Mounting Instructions

CSD Series Current Devices Split Core

MOONRING 1.5 & 3 MR1.5/MR3 SUSPENDED, CEILING. STANDARD SIZES 1.5" or 3" Aperture Ring diameters from 2 feet to 16 feet

poollux Power plx-pw60 & plx-pw100

Installation Instructions

CLARA CLA SUSPENDED, WALL, SURFACE

Installation Instructions

M Remote Mounting Kit

Motion and Light Sensor Kit LHBAS51

Installation Instructions

C.fm Page 1 Thursday, February 21, :28 AM Raptor user manual

Assembly instruction. Pendant Light Toccata GENERAL REMARKS ON SAFETY: Technical data: BOM

INSTALLATION INSTRUCTIONS

Fan Relay Board (FRBii) Assembly

Installation Instructions Shaper 1800 aircraft cable installation

BOLT 3544 ANATOMY BOLT SPECIFICATIONS LIGHT SOURCE MODULE MODULE LUMENS PER FOOT DELIVERED LUMENS FIXTURE WATTAGE 40.3W 40.

LED VaporProof Fixture

ALL200RM/ALL200RM-CM

UB-2 2 Universal Button

M9109-GGx-5 Series Proportional Electric Non-spring Return Actuators

In this kit there should be: 1 x Engine Case Cover (ECC0085) 2 x M6x28mm long button head bolts PLEASE READ THESE INSTRUCTIONS FULLY BEFORE STARTING

CSR COMPACT FUSED INTERLOCKED ARKTITE RECEPTACLE - 30 & 60 AMP Installation & Maintenance Information IF 1440

INSTALLATION INSTRUCTIONS For Light*Waves Flex II Kit with 300-Watt remote transformer

just the right angle

Installation Instructions

OWNER S MANUAL OM F

MONORAIL KITS INSTALLATION INSTRUCTIONS PENDANTS

VR44-MU-xxx-8yy-xxxxA

LED Utility Wrap Fixture

Transcription:

INSTALLATION INSTRUCTIONS MOONRING 1.5 MOONRING 3 MR1.5 & MR3 Suspended, Ceiling LED n A 1035 22nd Avenue, Unit 1 Oakland, CA 94606 P 510.489.2530 E TalkToUs@alwusa.com W alwusa.com

Safety & Warnings! 1. Read all instructions. 2. Install in accordance with national and local electrical code regulations. 3. This product is intended to be installed and serviced by a qualified, licensed electrician. 4. Only install with a compatible Class 2 LED Constant Current Driver. This product has not been evaluated for use when connected to an LED driver that does not comply with Class 2 voltage and energy limited supplies. 5. Do not install in wet locations. For dry and damp use only. 6. Turn off electrical power before installing or servicing fixture in any way. 7. To reduce the risk of fire and overheating, make sure all connections are tight. Attention! 1. Lisez toutes les instructions. 2. Installez conformément à la réglementation du code électrique national et local. 3. Ce produit est destiné à être installé et entretenu par un électricien agréé qualifié. 4. Installez uniquement avec un pilote de courant constant à DEL de classe 2 compatible. Ce produit n a pas été évalué pour une utilisation lorsqu il est connecté à un pilote de LED qui n est pas conforme aux alimentations de tension et d énergie limitée de classe 2. 5. Ne pas installer à l extérieur ou dans des endroits humides. Pour une utilisation en intérieur et sec seulement. 6. Coupez l alimentation électrique avant de évoluer le système d éclairage en aucune façon. 7. Pour réduire le risque d incendie et de surchauffe, assurez-vous que toutes les connexions sont bien serrées. SHOCK HAZARD! May result in serious injury or death. Turn power OFF at circuit breaker prior to installation or servicing. MR1.5/MR3 Installation Guide 2 of 14 IG101118-A.0

Table of Contents Luminaire Overview 4 Diagrams 4 Components 4 Parts (by others) 4 Tools Required 4 Quick Specs 4 Installation 5 Prepare Ceiling 5 Standard Suspension 5 Lens 7 Central Axis Suspension - Cable Coupler 8 Central Axis & Collared Central Suspension - Wedge Plate 10 Ceiling Mount 12 Troubleshooting 13 MR1.5/MR3 Installation Guide 3 of 14 IG101118-A.0

LUMINAIRE OVERVIEW CENTRAL AXIS SUSPENSION DIAGRAM STANDARD SUSPENSION DIAGRAM J-Box Canopy Bracket Canopy Power Cord Cable Coupler Suspension Cables Cable Gripper *For some models, Suspension Cables may be installed into Canopy and mounted to a Wedge Plate. STANDARD SUSPENSION COMPONENTS Canopy Assembly Suspension Bullet Suspension Cable Ceiling Fitting Parts (by others) Junction Box Wood Screws, #10, 1.5 long Tools Required Drill #2 phillips bit Wire strippers Quick Specs Input Voltage / Frequency: See product label Rated Power: See product drawing Ambient Temperature: -4 120 F (-20 50 C) Environment: Dry and damp locations MR1.5/MR3 Installation Guide 4 of 14 IG101118-A.0

Installation: Prepare Ceiling Installation: Standard Suspension SAMPLE DRAWING 1 See Final/Record Drawings for Mounting Locations See final/record drawings for mounting locations. Install framing or 1/4-20 ceiling rods with consideration for alignment of wiring and suspension mounting locations. 4A Install Canopy Fitting - Framing Canopy Fittings may be installed directly into framing with appropriate hardware. SAMPLE DRAWING 2 Install Canopy J-Box Install Canopy J-Box (sold separately) at power feed location per final/record drawing. 4B Install Canopy Fitting - Toggle Bolts Canopy Fittings may also be mounted using toggle bolts. 3 Install Remote Driver J-Box Install remote driver J-Box(es) in an accessible/ serviceable location. Run low voltage wire from Remote Driver J-Box to Canopy J-Box in accordance with local/ state/federal regulations. 4C Install Canopy Fitting - 1/4-20 Threaded Rods Canopy Fittings may also be mounted on 1/4-20 Threaded Rods. MR1.5/MR3 Installation Guide 5 of 14 IG101118-A.0

Installation: Standard Suspension (Cont.) 5 Route Suspension Cable and Attach to Ceiling Route Suspension Cable through Suspension Bullet. Ball end should sit in Suspension Bullet. Screw Suspension Bullet to Ceiling Fitting. 8 Raise Fixture to Suspension Cables Raise fixture to Suspension Cables, and attach fixture by inserting Suspension Cable through Cable Grippers. 6" 6 Cut Suspension Cables to Desired Length 9 Adjust Suspension Cable Length Use wire snips or shears to cut Suspension Cables to desired length. Keep an extra 6 inches of cable for adjustments. Adjust fixture until it is level and at desired height. Depress top of Cable Gripper to lower fixture. Keep fixture supported while lowering. Cut excess cable. 7 Connecting Multiple Sections (If Necessary) If necessary, connect all fixture sections with the provided Connector Bracket using two 8-32 x 1-1/8 screws and lock nuts. Ensure proper alignment to avoid fixture instability and light leak. 10 Bring Canopy to Ceiling Bring wiring and canopy assembly to J-box. Refer to final/record drawing to make wiring connections. Ensure Power is OFF prior to connecting wiring. MR1.5/MR3 Installation Guide 6 of 14 IG101118-A.0

Installation: Standard Suspension (Cont.) Installation: Lens 11 Mount Canopy Bracket to J-Box & Secure Canopy Mount Canopy Bracket to J-Box using provided screws, then secure Canopy over J-Box with finial. CAUTION: Do not pinch wire connections. 13A Install Downlight Lenses Carefully angle/snap lenses into fixture, as shown. Note: because lenses are not adhered to fixture, fixture may only be mounted at moderate angles. 12 Turn Power On Turn breaker ON and check if fixture operates as intended and that there are no loose connections. 13B Install Downlight Lenses Ensure lenses overlap, as shown. MR1.5/MR3 Installation Guide 7 of 14 IG101118-A.0

Installation: Central Axis Suspension (CAS) - Cable Coupler SAMPLE DRAWING 14 Prepare Ceiling Follow steps 1-3 to prepare ceiling. (Install framing, Canopy J-Box, and Remote Driver J-Box, then install wiring from Remote Driver J-Box to Canopy J-Box). 17 Raise Fixture to J-Box & Connect Wiring Raise fixture to ceiling, and install wiring per final/record drawing. For CCS, ensure wire is fed through collar prior to connecting wiring. Ensure Power is OFF prior to connecting wiring. 15 Route Suspension Cable through Cable Coupler Route Suspension Cable through Cable Coupler. Ball end should sit in Coupler. Set aside. 18 Secure Canopy Secure Canopy over J-Box with Cable Coupler. CAUTION: Do NOT pinch wires between J-Box/Canopy/ceiling surface. 6" 16 Install Canopy Bracket Install the threaded rod to the Canopy Bracket, then install Canopy Bracket to the Canopy J-Box. 19 Cut Suspension Cables to Desired Length Use wire snips or shears to cut Suspension Cables to desired length. Keep an extra 6 inches of cable for adjustments. MR1.5/MR3 Installation Guide 8 of 14 IG101118-A.0

Installation: CAS - Cable Coupler (Cont.) 20 Raise Fixture to Suspension Cables Raise fixture to suspension cables, and attach fixture by inserting suspension cable through cable grippers. 21 Adjust Suspension Cable Length Adjust fixture until it is level and at desired height. Depress top of Cable Gripper to lower fixture. Keep fixture supported while lowering. Cut excess cable. 22 Turn Power On Turn breaker ON and check if fixture operates as intended and that there are no loose connections. Proceed to step 13 for lens installation. MR1.5/MR3 Installation Guide 9 of 14 IG101118-A.0

Installation: Central Axis & Collared Central Suspension (CAS & CCS) - Wedge Plate SAMPLE DRAWING 23 Prepare Ceiling Follow steps 1-3 to prepare ceiling. (Install framing, Canopy J-Box, and Remote Driver J-Box, then install wiring from Remote Driver J-Box to Canopy J-Box). 26 For CCS: Run Cable Through Collar Run Suspension Cable through Collar, and adjust as necessary. Tighten Set Screws. 6" 24 Install Wedge Plate Install Wedge Plate onto J-Box. Ensure wiring routes through hole in Wedge Plate. 27 Cut Suspension Cables to Desired Length Use wire snips or shears to cut Suspension Cables to desired length. Keep an extra 6 inches of cable for adjustments. 25 Route Suspension Cable through Canopy Route Suspension Cable through holes in Canopy. Ball end should sit on inside of Canopy. 28 Attach Suspension Cables to Fixture Attach Suspension Cables to lighting fixture by inserting Suspension Cables through Cable Grippers on fixture. MR1.5/MR3 Installation Guide 10 of 14 IG101118-A.0

Installation: CAS & CCS - Wedge Plate (Cont.) 29 Raise Fixture to Ceiling & Connect Wiring Raise entire fixture to ceiling, and connect wiring per final/record drawing. Ensure Power is OFF prior to connecting wiring. 32 Turn Power On Turn breaker ON and ensure that fixture operates as intended and that there are no loose connections. Proceed to step 13 for lens installation. 30 Install Canopy onto Wedge Plate Install the Canopy onto the Wedge Plate using 3 set screws (included). CAUTION: Do NOT pinch wires between J-Box/Canopy/ceiling surface. 31 Adjust Suspension Cable Length Adjust fixture until it is level and at desired height. Depress top of Cable Gripper to lower fixture. Keep fixture supported while lowering. Cut excess cable. MR1.5/MR3 Installation Guide 11 of 14 IG101118-A.0

Installation: Ceiling Mount (3x) 5/8 Holes 33 Drill Holes in Ceiling & Install Remote Driver J-Box Drill three 5/8 holes in ceiling at mounting positions (per final/record drawing). Follow steps 2-3 to install Canopy J-Box and Remote Driver J-Box and run wiring. 36 Bring Fixture to Ceiling Bring fixture close to ceiling and align Ceiling Mount Brackets on fixture with Cleat Bosses. Ensure wiring location is correct. To Remote Driver Cleat Boss Mount 34 Install Non-Power Feed Cleat Bosses Install two non-power feed Cleat Bosses either directly into framing/blocking, onto a 1/4-20 rod, or using toggle bolts (refer to steps 4A-4C). Use a 1/2 washer (0.05-0.069 thickness) between Cleat Boss and ceiling. 37 Feed Wiring to Remote Driver Feed wiring through the grommet on cover plate and route through ceiling to Remote Driver. 2 ø 5/8 35 Install Power Feed Cleat Boss One of the Cleat Bosses will have a power feed - make another 5/8 hole 2 from one of the Cleat Boss holes for wiring from fixture to remote driver. 38 Install Non-Power Feed Cleat Bosses Insert Retaining Pins, ensuring that they click into place around Boss and sit in gap between Mount Bracket and Collar of Boss. CAUTION: Do NOT pinch wires during this process. Proceed to step 13 for lens installation. MR1.5/MR3 Installation Guide 12 of 14 IG101118-A.0

Wiring Diagrams Traditional On/Off L N AC 50/60Hz Line Voltage (Hot) Line Voltage (Neutral) Ground Black White Green Remote LED Driver J-Box DC Driver 1 LED + Driver 1 LED - Driver 2 LED + Brown Blue Yellow Canopy/Power Feed Driver 2 LED - Orange 0-10V Dimming L N AC 50/60Hz DIM- DIM+ Line Voltage (Hot) Line Voltage (Neutral) Ground 0-10VDC (Dim-) 0-10VDC (Dim+) Black White Green Grey Purple Remote LED Driver J-Box DC Driver 1 LED + Brown Driver 1 LED - Blue Driver 2 LED + Yellow Driver 2 LED - Orange Canopy/Power Feed DMX L Line Voltage (Hot) Black N AC 50/60Hz DMX In Shield DMX in - DMX in + Line Voltage (Neutral) Ground DMX in shield DMX in - DMX in + White Green Clear Black Red Remote LED Driver/Decoder J-Box DC Driver 1 LED + Brown Driver 1 LED - Blue Driver 2 LED + Yellow Driver 2 LED - Orange Canopy/Power Feed DMX Out Shield DMX out shield Clear DMX out - DMX out - Black DMX out + DMX out + White DALI L N AC 50/60Hz DATA + DATA - Line Voltage (Hot) Line Voltage (Neutral) Ground Data + Data - Black White Green Purple Grey Remote LED Driver/Decoder J-Box DC Driver 1 LED + Brown Driver 1 LED - Blue Driver 2 LED + Yellow Driver 2 LED - Orange Canopy/Power Feed Lutron LDE L N AC 50/60Hz E1 E2 Line Voltage (Hot) Line Voltage (Neutral) Ground E1 E2 Black White Green Purple Grey Remote LED Driver J-Box DC Driver 1 LED + Brown Driver 1 LED - Blue Driver 2 LED + Yellow Driver 2 LED - Orange Canopy/Power Feed MR1.5/MR3 Installation Guide 13 of 14 IG101118-A.0

Troubleshooting Only a certified electrician can service and troubleshoot product field issues. Always turn main power off before servicing fixture. Full Fixture does not illuminate Ensure all wire connections are made. Ensure fixture is wired correctly and power is on. Check that circuit breaker is on and not off or tripped. Class 2 LED remote driver may be defective. Fixture section(s) do not illuminate Possible loose low voltage DC + or - connection between LED boards or from LED driver to LED boards. Some fixtures contain multiple LED drivers. In this case, it s possible one of the drivers is defective, which will cause the LED connected to the driver not to illuminate. Call tech support. Full fixture is flickering 0-10V, DMX, and DALI Dimming Models: Ensure polarity is correct for DATA + and - connections. Swapping DATA + and - connections can cause flickering. TRIAC Dimming Models: Ensure a compatible TRIAC Forward Phase dimmer is connected to fixture. Call tech support for further information. Possible loose DATA + and - connections from fixture to 0-10V, DMX, or DALI control. Possible loose low voltage DC + or - connection from driver to LED. Call customer support. Fixture section(s) are flickering Possible loose low voltage DC + or - connection between LED boards. Fixture does not dim 0-10V, DMX, and DALI Dimming Models: Ensure polarity is correct for DATA + and - connections. Swapping DATA + and - connections can cause flickering. TEST. TRIAC Dimming Models: Ensure a compatible TRIAC Forward Phase dimmer is connected to fixture. Call tech support for further information. Possible loose DATA + and - connections from fixture to 0-10V, DMX, or DALI control. MR1.5/MR3 Installation Guide 14 of 14 IG101118-A.0