R&S RT-ZC02 R&S RT-ZC03 AC/DC Current Probe User Manual

Similar documents
CP GermanCp 41_CP C. Operating Instructions. CP 30 CP 330 CP 1100 AC/DC current probe /7.10

1 INTRODUCTION SPECIFICATIONS Electrical Data General Data... 3

LH41A. User Manual. Clamp On Ammeter. For detailed specifications and ordering info go to

The following table shows the symbols used on the product and/or in this manual. Hazardous Voltage. Risk of electric shock.

362 Clamp Meter. Users Manual

323/324/325 Clamp Meter

i400s Calibration Information Introduction

i3000s/i2000 Flex AC Current Probe

362 Clamp Meter. Users Manual

365 Detachable Jaw True-rms Clamp Meter

Users Manual. Accessories Motor and Phase Rotation Indicator ships with the following items: 3 test leads 3 test probes 3 alligator clips 9 V battery

302+/303 Clamp Meter. Users Manual

BT508/BT510/BT520/BT521 Battery Analyzer Safety Sheet

373 Clamp Meter. Users Manual

Flex current clamps A 1179 A 1257 A 1395 User Manual Version 1.6; Code No

Low Amp Probe EETA308A

Users Manual. Phase Rotation Indicator

RS-3 PRO RS-1007 PRO. CAT IV Analog Clamp meter Series. Users Manual. For detailed specifications and ordering info go to

AC/DC CURRENT TRANSDUCER 600A 10mV/1A, 1mV/1A

DT33B/C/D OPERATOR S MANUAL LIMITED WARRANTY AND LIMITATION OF LIABILITY

Go to to register your product and find more information.

WPS bar, 60 MPa, 8700 psi Hydraulic Pressure Transducer. User s Guide

1587 FC/1587/1577. Insulation Multimeter. Safety Information. Warnings

1662/1663/1664 FC. Electrical Installation Tester. Safety Information. Warnings

Calibration Manual. Detachable Jaw True-rms Clamp Meter

MM300. INSTRUCTION MANUAL Manual-Ranging Digital Multimeter

AC/DC CURRENT TRANSDUCER INSTRUCTION MANUAL

INSTRUCTION MANUAL CM69 TRMS AC EARTH LEAKAGE CLAMP METER. 1. SAFETY INFORMATION: Always read before proceeding. REMEMBER: SAFETY IS NO ACCIDENT

MY /2-DIGIT DIGITAL MULTIMETER Users Manual

190M. Medical ScopeMeter. Safety Information

BK BK J93 MA BK MA BK MN93-BK MN193-BK MR193-BK SL261-BK SR193-BK

WPS600. Hydraulic Pressure Transducer. User s Guide. 600 bar 60 MPa 8700 psi

INSTRUCTION MANUAL CM95/ CM100 TRUE RMS FLEXIBLE CLAMP METER. 1. SAFETY INFORMATION: Always read before proceeding. REMEMBER: SAFETY IS NO ACCIDENT

Instruction Manual ICM A1 AC/DC Clamp Meter ICM A1

BK BK A BK MA BK MA BK J93 MN93-BK MN193-BK MR193-BK SL261-BK SR193-BK

233 True-rms Remote Display Digital Multimeter Safety Information

WPS500X 500 psi /34.5 bar Automotive Pressure Transducer. User s Guide

Calibrator Capabilities Function Range Resolution Measure V dc 28 V 1 mv Measure ma dc Source ma dc

Vol-Con XL (61-086) Voltage/Continuity Tester and Vol-Test (61-085) Voltage Tester Instruction Manual WARNING

80 Series V Digital Multimeter Safety Information

MAX. AC 600V HOLD V M H.V. LIVE CIRCUIT DIGITAL INSULATION TESTER DO NOT OPERATE IF LIT POWER DATA HOLD TEST ON / OFF 250V 500V 1000V OFF CAT.

Digital Multimeter User's Manual

2-Year Limited Warranty. See the Users Manual for the full warranty.

3-Year Limited Warranty. See the Users Manual for the full warranty.

INSTRUCTION MANUAL MARTINDALE CM52 CLAMP METER. ELECTRIC Trusted by professionals. Other products from Martindale:

MOdel No: MM19.V3 WARNING CAUTION 1. SAFETY INSTRUCTIONS

707Ex. Users Manual. ma Calibrator

ASTROAI USER MANUAL DIGITAL MULTIMETER. NOTE: Fully read and understand this manual before using this instrument.

K100 K110 AEMC INSTRUMENTS ENGLISH. User Manual. n DC/AC MICROPROBE. Model K mv/ma OFF. DC/AC MicroProbe

Automatic Pressure Calibrator. 3-Year Limited Warranty. See the Users Manual for the full warranty.

WPS500X. 500 psi / 34.5 bar Automotive Pressure Transducer. User s Guide

& HIGH CURRENT DC POWER SUPPLIES INSTRUCTION MANUAL

Table of Contents. Title Page UT501/UT502 OPERATING MANUAL. Introduction. Unpacking the Meter. Safety Information. International Electrical Symbols

KV4-300 mk2. KV5-200 mk2. KV5-100T mk2. KV3-250 mk2

Rental Industry Safety Tester Safe Check 5s

MARTINDALE INSTRUCTIONS ELITE FUSE FINDER KIT ELECTRIC. Trusted by professionals. 4.4 Storage Conditions

Manual Supplement. For IEC V, CAT I & 600, CAT II Meters only. Serial NO and greater.

PRM-4. Phase Sequence and Motor Rotation Tester. Users Manual. For detailed specifications and ordering info go to

INSTRUCTION MANUAL IDM93N DIGITAL MULTIMETER EN FR IT DE

PY-11 Voltage & Continuity Tester

Model UT601: OPERATING MANUAL

1.Safe testing IMPORTANT:

USER MANUAL. 200A AC Mini Clamp Meter. Model MA130. Please visit for user manual translations

INSTRUCTION MANUAL IDM97II DIGITAL MULTIMETER EN FR IT DE

DC POWER SUPPLY ALIMENTATION C.C.

OPERATING INSTRUCTION

LEM~flex RR3020 AC Current Probe Operating Instructions Mode d emploi Bedienungshandbuch Manuale Operativo Manual de uso

USER MANUAL. Insulation Tester + DMM. Model MG320

Megohmmeter Test Probe

Visit us at

INSTRUCTION MANUAL IDM91E DIGITAL MULTIMETER EN FR IT DE JP

746 Wrist Strap Tester Installation, Operation and Maintenance

Instruction Manual PC104/PC105 3-PHASE SOCKET TESTER. Check out what else you can get from Martindale:

99 Washington Street Melrose, MA Fax TestEquipmentDepot.com. Instruction Manual. Model 2831D 4 ½ Digit True RMS Digital Multimeter

ICA 39T INSTRUCTION MANUAL ICA39T AC/DC CURRENT TRANSDUCER

Switching DC Power Supply

KMP Insulation-Continuity Tester. Users Manual

51 & 52 Series II. Users Manual. Thermometer. Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.

Dawson DDM190D. Digital Multimeter User s Manual

OPERATING AND MAINTENANCE MANUAL. Primary Current Injection Test Set. 750ADM-H mk2

KSZ 10B Current Probe Calibrator. Instruction Manual

INSTRUCTION MANUAL DT173 DT175 DIGITAL THERMOMETERS ALWAYS READ THESE INSTRUCTIONS BEFORE PROCEEDING

Instruction Manual. 99 Washington Street Melrose, MA Fax TestEquipmentDepot.com. Model 308A Digital Insulation & Continuity Meter

INSP-3 Wiring Inspection Tester

BM kv Digital Insulation Tester USER MANUAL

Model UT602/603: OPERATING MANUAL

INSTRUCTION MANUAL ANALOGUE INSULATION TESTER KEW 3131M KYORITSU ELECTRICAL INSTRUMENTS WORKS,LTD., TOKYO JAPAN

TX900. Microwave Leakage Detector. 99 Washington Street Melrose, MA Phone Toll Free

l The Battery Tester is designed for measuring the l AC four-terminal method to measure the internal

Autoranging Industrial Multimeter

OPERATING INSTRUCTIONS

USE AND CARE GUIDE DUALCHECK CIRCUIT TESTER

PD-20 HIGH VOLTAGE PROBE INSTRUCTION MANUAL

Instruction Manual VT4 VOLTAGE TESTER. Check out what else you can get from Martindale:

MODEL No: TA SAFETY INSTRUCTIONS 2. FEATURES. fig.1. Original Language Version

Users Manual. Airflow Meter

27 II/28 II. Digital Multimeters. Getting Started Manual. Specifications

Users Manual. MegOhmMeter

POWERED BY KT71 / Portable Appliance Tester. Instruction Manual

1 This instrument must only be used by a competent and trained person and operated in strict accordance with the instructions.

Transcription:

R&S RT-ZC02 R&S RT-ZC03 AC/DC Current Probe User Manual / User Manual

Content 1 Introduction 3 2 Safety 3 3 Specifications RT-ZC03 6 Specifications RT-ZC02 7 4 Operating Instructions RT-ZC03 8 Operating Instructions RT-ZC02 9 4.1 Switch On 4.2 Zero Adjustment 4.3 Current Measurement 4.4 Auto Power OFF 4.5 Battery Replacement 4.6 Maintenance 12 12 12 12 12 13 5 Warranty and Repair 13 2 Subject to change without notice

1 Introduction The current probe has been designed for use with multimeters and oscilloscopes respectively for accurate, nonintrusive measurement of AC, DC and complex waveform currents using advanced Hall Effect technology. Key features: RT-ZC03 RT-ZC02 Measurement range 5 ma to 30 A 500 ma to 1000 A Resolution 1 ma 100 ma/500 ma Frequency range DC to 100 khz DC to 20 khz Connector RT-ZCxx BNC BNC HZCxx dual 4 mm dual 4 mm These features make it a powerful tool for use in inverters, switch mode power supplies, industrial controllers and other applications requiring current measurement and/or waveform analysis. 2 Safety The following symbols appear on the products: Symbol ~ W T - P Description Do not dispose of of this product as as unsorted municipal waste. Contact Fluke Rohde or & a Schwarz quadfcycler GmbH for & Co. KG disposal. or a qualified recycler for disposal. Important Information. See manual. Double insulation. Do not apply around or remove from the HAZARDOUS LIVE conductors. Complies with the relevant European standards. Subject to change without notice 3

Warning The current probe may only be used and handled by qualified personnel. To avoid personal injury, follow these precautions: To avoid electric shock, use caution during installation and use of this product; high voltages and currents may be present in circuit under test. Do not use the product if damaged. Always connect probe to display device before it is installed around the conductor. Always ensure the probe is removed from any live electric circuit, and leads are disconnected before removing the battery cover. Use the Current Probe only as specified in the operating instructions; otherwise the current probe s safety features may not protect you. Adhere to local and national safety codes. Individual protective equipment must be used to prevent the shock and arc blast injury where hazardous live conductors are exposed. Do not hold the Current Probe anywhere beyond the tactile indicator. Before each use, inspect the Current Probe. Look for cracks or missing portions of the Current Probe housing or output cable insulation. Also look for loose or weakened components. Pay particular attention to the insulation surrounding the jaws. Use caution when working with voltages above 60 V DC, 30 V AC rms or 42 V AC peak. Such voltages pose a shock hazard. Use of this equipment in a manner not specified herein may impair the protection provided by the equipment. CAT III equipment is designed to protect against the transients in the equipment in fixed equipment installations, such as distribution panels, feeders and short branch circuits, and the lighting systems in large buildings. Always inspect the probe and lead for damage before use. To avoid electric shock, keep the probe clean and free of surface contamination. Safety in its use is the responsibility of the operator who must be a suitably qualified and authorised person. Ensure that your fingers are behind the protective barrier when using the probe. 4 Subject to change without notice

Safety Standards EN 61010-1 EN 61010-2-032 300 V RMS Cat III, Pollution Degree 2 EMC Standards EN 61326-2-2 ROHS and WEEE compliant This product is designed to be safe under the following conditions: indoor use altitude up to 2000 m temperature 0 C to +50 C maximum relative humidity 80% for temperatures up to 31 C decreasing linearly to 40% relative humidity at 50 C. Use of the probe on uninsulated conductors is limited to 300 V RMS AC or DC and frequencies below 1 khz. Subject to change without notice 5

3 Specifications RT-ZC03 Electrical Characteristics (all accuracies stated at 23 C ±1 C) Nominal input current 20 A RMS, AC or DC Measuring range ±30 A Overload capacity ±500 A Overall DC accuracy ±1% of reading ±2m A, typ. Resolution 1m A Output noise level 200 µv RMS, typ. Gain variation ±0.01% of reading/ C, typ. Output sensitivity 100m V/A Frequency range DC to 100 khz (0.5 db), typ. Max. slew rate ±20 A/µs, typ. Response time better than 1 µs Working voltage 300 V RMS AC or DC General data Operating temperature Storage temperature with battery removed Power supply Battery life Load impedance (minimum) Conductor size Weight Output cable and connectors RT-ZC03 0 C to +50 C 20 C to +85 C 9 V Alkaline battery PP3, MN 1604 or IEC6LR61 25 hours, typ. > 100kΩ and 100pF 25 mm diameter 320 g 2 m long coax terminated with a safety BNC connector 50 Ohms 6 Subject to change without notice

Specifications RT-ZC02 Electrical Characteristics (all accuracies stated at 23 C ±1 C) Nominal current In 1000 A RMS AC or DC Measuring range ±200/±2000 A Overload capacity ±2000 A Overall DC accuracy (0 A... 200 A / 1500 A) ±1% of reading ±0.1/0.5 A, typ. Overall DC accuracy (1500 A... 2000 A) ±5% of reading Resolution 100/500 ma Output noise level 600 µv RMS /10 µv RMS, typ. Gain variation ±0.15% of reading/ C, typ. Output sensitivity 10 / 1 mv/a Frequency range DC to 20 khz (-3 db), typ. Max. slew rate ±20 A/µs, typ. Response time better than 5 µs Working voltage 300 V RMS AC or DC General data Operating temperature 0 C to +50 C Storage temperature with battery removed 20 C to +85 C Power supply 9 V Alkaline battery PP3, MN 1604 or IEC6LR61 Battery life 50 hours, typ. Load impedance (minimum) > 100 kω and 100pF Conductor size 32 mm diameter Weight 320 g Output cable and connectors 2 m long coax terminated RT-ZC02 with a safety BNC connector 50 Ohms Subject to change without notice 7

4 Operating Instructions RT-ZC03 1 2 3 4 5 4 6 7 9 8 1 Jaws 2 Conventional current direction 3 Tactile Barrier 4 Battery cover 5 Battery cover screw 6 Jaw trigger 7 ON/OFF switch 8 Auto zero button 9 LED 8 Subject to change without notice

Operating Instructions RT-ZC02 1 2 3 4 5 4 6 7 9 8 1 Jaws 2 Conventional current direction 3 Tactile Barrier 4 Battery cover 5 Battery cover screw 6 Jaw trigger 7 ON/OFF and range switch 8 Auto zero button 9 LED Subject to change without notice 9

Typical performance Plots RT-ZC03 Phase Shift in Degrees Relative Gain in db 0-5 -10 10 100 1000 10000 Frequency (Hz) 100000-15 -20 10 Subject to change without notice

Typical performance Plots RT-ZC02 CP1005 Frequency Response Gain db 1000A Gain db 100A 0.5 0 10 100 1000 10000 100000-0.5 Relative Gain in db Gain (wrt 100 in Hz) db -1-1.5-2 -2.5-3 Frequency (Hz) CP1005 Phase Response phase 100A phase 1000A 0.00-5.00 10 100 1000 10000 100000-10.00 Phase Shift in Degrees -15.00-20.00-25.00-30.00-35.00-40.00-45.00 Frequency (Hz) Warning To avoid injury, when using the probe ensure that your fingers are behind the protective barrier. Do not use the probe if any part of the probe, including the lead and connector(s), appear to be damaged or if a malfunction of the instrument is suspected. Subject to change without notice 11

4.1 Switch On When the probe is switched on, the green LED will illuminate. The LED starts flashing when the battery voltage is too low for normal operation and warns the user that it requires changing. This procedure is described in Section 4.5. 4.2 Zero Adjustment The output zero offset voltage of the probe may change due to thermal shifts and other environmental conditions. To null the output voltage depress the Auto Zero button. Ensure that the probe is away from the current carrying conductor whilst the probe is being nulled. 4.3 Current Measurement Switch on the probe and check that the LED is lit. Connect the output lead to an oscilloscope, multimeter or other measuring equipment. Zero the probe using the Auto Zero button. Clamp the jaws of the probe round the conductor ensuring a good contact between the closing faces of the jaws. Observe and take measurements as required. Positive output indicates that the current flow is in the direction shown by the arrow on the probe. 4.4 Auto Power OFF In order to save battery life, the probe will automatically switch itself off after approximately 10 minutes. To disable the Auto power off function, Switch Off the probe and Switch On whilst pressing the auto zero button. The red LED will illuminate and the probe will stay On until switched off again. 4.5 Battery Replacement Warning To avoid personal injury, always ensure the probe is removed from any live electric circuit, and leads are disconnected before removing the battery cover. Never operate the probe without the battery cover fitted. The green or red LED will flash when the minimum operating voltage is approached. Use the following procedure. Unclamp the probe from the conductor, turn it off using the On - Off switch and disconnect the output leads, from external equipment. 12 Subject to change without notice

Loosen the captive screw which secures the battery cover. Lift the cover through 30 and pull it clear of the probe body. Replace the battery and re-fit the battery cover and fasten the screw. Note: Replacement with other than the specified type of battery will invalidate the warranty. Fit only the type 9 V PP3 Alkaline (MN 1604). 4.6 Maintenance Clean the case periodically by wiping it with a damp cloth and detergent. Use isopropyl alcohol to clean the electronics unit and the probe. Do not use abrasive cleaners or solvents. Do not immerse the probe in liquids. 5 Warranty and Repair Our instruments are subject to strict quality controls. Prior to leaving the manufacturing site, each instrument undergoes a 10-hour burn-in test. This is followed by extensive functional quality testing to examine all operating modes and to guarantee compliance with the specified technical data. The testing is performed with testing equipment that is calibrated to national standards. The statutory warranty provisions shall be governed by the laws of the country in which the product was purchased. In case of any complaints, please contact your supplier. The product may only be opened by authorized and qualified personnel. Prior to working on the product or before the product is opened, it must be disconnected from the AC supply network. Otherwise, personnel will be exposed to the risk of an electric shock. Any adjustments, replacements of parts, maintenance and repair may be carried out only by authorized technical personnel. Only original parts may be used for replacing parts relevant to safety (e.g. power switches, power transformers, fuses). A safety test must always be performed after parts relevant to safety have been replaced (visual inspection, PE conductor test, insulation resistance measurement, leakage current measurement, functional test). This helps ensure the continued safety of the product. Subject to change without notice 13

2018 Rohde & Schwarz GmbH & Co. KG Mühldorfstr. 15, 81671 München, Germany Phone: +49 89 41 29-0 Fax: +49 89 41 29 12 164 E-mail: info@rohde-schwarz.com Internet: www.rohde-schwarz.com Customer Support: www.customersupport.rohde-schwarz.com Service: www.service.rohde-schwarz.com Subject to change Data without tolerance limits is not binding. R&S is a registered trademark of Rohde & Schwarz GmbH & Co. KG. Trade names are trademarks of the owners. Throughout this manual, products from Rohde & Schwarz are indicated without the R&S symbol, e.g. R&S RT-ZC03 is indicated as RT-ZC03. 1333.0844.02 Version 02 RT-ZC03 1333.0850.02 Version 02 RT-ZC02