ABB Power T&D Company Inc. Relay Division Coral Springs, FL Allentown, PA. Non-Directional, Single Phase Adjustable Time Delay Device No.

Similar documents
www. ElectricalPartManuals. com Type CO Overcurrent Relays E ABB Power T&D Company Inc. Relay Division Coral Springs, FL Allentown, PA

2.0 CONSTRUCTION AND OPERATION 3.0 CHARACTERISTICS K. CO (HI-LO) Overcurrent Relay

L. Photo. Figure 2: Types CA-16 Relay (rear view) Photo. Figure 1: Types CA-16 Relay (front view)

Type SOQ Negative Sequence Time Overcurrent Relay

C. Figure 1. CA-16 Front View Figure 2. CA-16 Rear View

ABB. Type CRQ Directional Negative Sequence Relay for Ground Protection B 1.0 APPLICATION 2.0 CONSTRUCTION AND OPERATION CAUTION

3.0 CHARACTERISTICS E Type CO-4 Step-Time Overcurrent Relay

Type CRN-1 Reverse Power Relay 50 and 60 Hertz

COM Overcurrent Relay

Figure 1. Type CWP-1 Ground Relay (Front View) Figure 2. Type CWP-1 Ground Relay (Rear View) E

B CW POWER RELAY

A - Add New Information C - Change Existing Information D - Delete Information. Page 7. Delete the fourth paragraph beginning CAUTION

ABB ! CAUTION. Type KRV Directional Overcurrent Relay E 1.0 APPLICATION 2.0 CONSTRUCTION AND OPERATION. Instruction Leaflet

ABB Automation Inc. Substation Automation and Protection Division Coral Springs, FL 33065

TABLE I 60 CYCLE BURDEN OF THE CVD RELAY AT CONTINUOUS RATING

P. Sub 4 184A404. Sub 3 876A220

TYPE KF UNDER-FREQUENCY RELAY A. Figure 1: Type KF Relay for 60 Hertz without Case. (Front & Rear View.) Front View Rear View

Data Bulletin. Ground-Censor Ground-Fault Protection System Type GC Class 931

ABB Automation, Inc. Substation Automation & Protection Division Coral Springs, FL Allentown, PA

Type CDG 14 Extremely Inverse Time Overcurrent and Earth Fault Relay

41-747G. Figure 1: Type DGF Relay without case (Photo)

3. OPERATION 2.1. RESTRAINT CIRCUIT 2.6. INDICATING CIRCUIT 2.2. OPERATING CIRCUIT 2.7. SURGE PROTECTION CIRCUIT 2.3.

4.0 OPERATION Type ITH-T Relay

The University of New South Wales. School of Electrical Engineering and Telecommunications. Industrial and Commercial Power Systems Topic 6

Sectionalizing. Rick Seeling. Pete Malamen. Introduction Philosophy. Three Phase Reclosers High-Side Protection Specific Applications

ACS motor protection circuit breakers KT 7 Introduction

HGA. Hinged Armature Auxiliary. Hinged armature auxiliary relay to perform auxiliary functions in AC and DC circuits.

A system fault contribution of 750 mva shall be used when determining the required interrupting rating for unit substation equipment.

2.0 CONSTRUCTION 3.0 OPERATION. SA-1 Generator Differential Relay - Class 1E 2.5 TRIP CIRCUIT

A. Submit manufacturer's literature and technical data before starting work.

INSTRUCTIONS. seconds. the tween the end of the bearing screw and the. top of the shaft. The moving contact is a small silver hemisphere

UBC Technical Guidelines Section Edition Commissioning of Electrical Systems Page 1 of 5

Westinghouse Electric Corporation Distribution and Control Business Unit Assemblies Division Bloomington, Indiana

SECTION MOTOR CONTROL

Module 2 CONTROL SYSTEM COMPONENTS. Lecture - 4 RELAYS

www. ElectricalPartManuals. com MAGNETIC TIME RELAYS GENERAL. ELECTRIC INSTRUCTIONS *IC *Also identified with prefix CR instead of IC.

Michigan State University Construction Standards SECONDARY UNIT SUBSTATIONS PAGE

ADDITIONAL INFORMATION. BE1-50/51B SELF POWERED TIME OVERCURRENT RELAY and RETROFIT KITS. FEATURES and APPLICATION Page 2

MAGNETIC MOTOR STARTERS

Inverse-Time Overcurrent & E/F Relays. Type ICM 21, ICM 21B. Station Automation & Protection. ABB Substation Automation Products

Protectors. Manual motor. Types MS116, MS132, MS45x, MS49x. MS Series. Manual motor protectors. Type MS116. Type MS132. Type MS45x.

Industrial Generator Set Accessories. Standard Features. Line Circuit Breakers kw

Selective Coordination

Miniature circuit breaker Application guide

INSTRUCTIONS HAA 15A / 15B / 15C / 15D / 15E / 15F / 15G / 15H AUXILIARY CURRENT RELAYS

SECTION MICROPROCESSOR TRIP UNITS FOR LV CIRCUIT BREAKERS. This section is organized as indicated below. Select desired Paragraphs.

ECET 211 Electric Machines & Controls Lecture 8 Motor Control Circuits (1 of 2) Lecture 8 Motor Control Circuits

SECTION MOTOR CONTROLLERS

ISO Rules Part 500 Facilities Division 502 Technical Requirements Section Interconnected Electric System Protection Requirements

Characteristics of LV circuit breakers Releases, tripping curves, and limitation

Descriptive bulletin. Medium voltage load interrupter switchgear Reliable, low maintenance and economical for distribution applications

S&C TripSaver II. Cutout-Mounted Recloser. For enhanced lateral circuit protection at 15 kv and 25 kv

BBC. Renewal Parts. I-T-E Low-Voltage Power Circuit Breakers

Self-protected Combination Starters System PKZ 2-SP

KD LV Motor Protection Relay

BE1-50/51B with S1 Case or FT-11 sized Case and Cover For non-retrofit applications, see Product Bulletin UHD.

INSTRUCTION MANUAL PROTECTIVE RELAY TEST SET MODEL SR-76A. For SERIAL NO.

FULL VOLTAGE STARTERS z SIZE 8 SERIES B CONSTRUCTION

Page 2 DS LOW VOLTAGE POWER CIRCUIT BREAKERS Digitrip Trip Unit Inside Wiring Guide Outside Wiring Guide Shutter Drawout Unit Position Indicator Escut

R-MAG. Vacuum Circuit Breaker with Magnetic Actuator Mechanism

ECET Distribution System Protection. Overcurrent Protection

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION MOTORS, STARTERS & DRIVES

Shunt Capacitor Bank Protection in UHV Pilot Project. Qing Tian

Figure 1. Non-removable buttonhead Edison Links. TABLE 1 Edison Link Fuse Designs. System Fuse Ampere Rating Type Rating

1. Take the cover off the relay, taking care to not shake or jar the relay or other relays around it.

ELECTRICAL MAINTENANCE

SURE-TRIP OEM RELACEMENT TRIP UNIT

Horizontal Circuit Switchers

INSTRUCTIONS. GE Protection and Control. 205 Great Valley Parkway Malvern, PA UNDERVOL TAGE RELAYS TYPES: IAV54E IAV55C IAV54F IAV55F

Horizontal Circuit Switchers

INSTRUCTIONS. GEI-38974A Supersedes GEI INSTANTANEOUS CURRENT RELAY TYPE PJC2OA GENERALS ELECTRIC

Electric Motor Controls BOMA Pre-Quiz

Individual breakers in separate enclosures can be applied in low voltage distribution systems through 600 volts Ac, 50/60 Hertz.

IN2 Enclosed Switches and Circuit Breakers

Chapter 8. Understanding the rules detailed in the National Electrical Code is critical to the proper installation of motor control circuits.

Direct On Line (DOL) Motor Starter. Direct Online Motor Starter

PORTABLE CURRENT SOURCE FOR CIRCUIT BREAKER AND MOTOR OVERLOAD TESTING INSTRUCTION MANUAL PI-250B. Release 1.0 April 5, 2013

Section SWITCHBOARDS. Introduction. Part 1 - General. Related Work

SECTION PANELBOARDS

XT IEC Power Control Manual Motor Protectors

SURE TRIP RETRO KITS

Motor Protection. Presented By. Scott Peele PE

SECTION MOTOR CONTROLLERS

R-MAG Vacuum Circuit Breaker with Magnetic Actuator Mechanism 15.5 kv - 27 kv; 1200 A A

NEMA Contactors & Starters (Freedom)

SECTION 4 ELECTRIC MOTORS UNIT 17: TYPES OF ELECTRIC MOTORS UNIT OBJECTIVES UNIT OBJECTIVES 3/21/2012

A. This Section includes ac, enclosed controllers rated 600 V and less, of the following types:

www. ElectricalPartManuals. com BBC Brown Boveri Electric Renewal Parts 1-T -E Low-Voltage Power Circuit Breakers

3.2. Current Limiting Fuses. Contents

Pretest Module 29 High Voltage Unit 1

A. This Section includes Low Voltage Switchgear Work, as indicated on the drawings, and as specified herein.

Motor Protection Fundamentals. Motor Protection - Agenda

Industry Automation Control Components

1. The term "withstand" means "the unit will remain in place without separation of any parts from the device when subjected to the seismic forces.

Motor-drive mechanism, type BUL. Technical guide

Transformer Protection

DIVISION 26 ELECTRICAL SECTION CIRCUIT BREAKERS

www. ElectricalPartManuals. com INSTRUCTIONS TYPE CO CONTACT MAKING AMMETER INSTALLATION OPERATION MAINTENANCE I.. L APPLICATION

Instructions for A200, A210, A250 size 6, two- or three-pole non-reversing or reversing motor controllers

G-Series. Circuit Breaker.

Transcription:

September, 1990 Supersedes Descriptive Bulletin 41-100, pages 1-4, dated June, 1989 Mailed to: E, D, C/41-100A Hi-Lo co induction-disc type overcurrent relays are activated when the current in them exceeds given values. The circuit closing type relays are normally used to trip a circuit breaker. They may have either single or double contacts for tripping one or two circuit breakers. The complete, coordinated line assures accurate, reliable primary and backup protection for phase or ground faults. Seven different time curves are available for system coordination. ABB Power T&D Company Inc. Relay Division Coral Springs, FL Allentown, PA Non-Directional, Single Phase Adjustable Delay Device No. 51 or 50/51 Features The traditional CO design advantages: Low burden, high thermal capacity, negligible temperature error. Accurate pickup, continuous "between tap adjustment". Simple, easy to get at, settings. Space saving Flexitest case for semi-flush or projection mounting. Two Wide Ranges The Hi-Lo CO relay offers two wide ranges; a high and a low. Hi Range The "Hi" range has an induction-disc time unit, rated 1 to 12 amperes with 14 taps. To complement the time unit, the relay is available with an instantaneous unit rated 6 to 144 amps with three tap positions. The core screw of the instantaneous unit is used to set the actual current pickup within any one of the three ranges. The 1-12 amp. time unit along with the 6-144 amp. instantaneous unit in one relay style offers considerable savings in stocking and flexibility of application. This one rating will satisfy the phase and ground requirements in most cases. Lo Range The "Lo" range CO contains the same 0.5 to 2.5 amp induction-disc time unit with 7 taps as standard CO relay designs. However, the instantaneous unit has a wide range of 2 to 48 amperes using 3 taps. The core screw of the instantaneous unit is used to set the actual current pickup within the range used. Descriptive Bulletin Page 1 Type Hi-Lo CO Overcurrent Relays The 0.5-2.5 amp. time unit and 2-48 amp. instantaneous unit combination result in substantial stock advantage of relays for ground fault protection and other low current applications. Induction Disc Unit Ranges & Taps --- -- Ground (0.5-2.5A) Lo Range 0.5, 0.6, 0.8, 1.0, 1.5, 2.0, 2.5 Ground & Phase Unit (1-12Al Hi Range 1.0, 1.2, 1.5, 2.0, 2.5, 3.0, 3.5, 4, 5, 6,7,8,10,12 IlIst ntl!n o Unit Ran{!El!_I!t_Taps Ground (2-48A) Lo Range 2-7, 7-14,14-48 Ground or Phase Unit (6-144A) Hi Range 6-20, 20-40, 40-144 Setting Adjustments All adjustments are made from the front of the relay. The taps eliminate the need to switch leads. All settings are readily visible from the front of the relay through the glass window of the cover. Interchangeability Electrically and mechanically interchangeable with all existing CO relay installations.

Descriptive Bulletin Page 2 Factors to Consider in Selecting Proper Relay Type Apparatus or Circuit to be Protected: In general, the application will indicate the use of a specific relay. Short-time relays act fast to avoid equipment damage. Long-time relays hold off tripping on heavy initial overloads or more extended moderate overloads. At higher fault currents, definite-time and moderately inverse relays maintain constant operating time, despite variation in connected generation and fault currents. and extremely inverse relays operate respectively faster on higher fault currents. Selective Operation, Sequential Tripping: To maintain maximum continuity of service, as small a section as possible should be removed from a system during a fault. A common method is to set each successive relay, progressing from the generator, to operate 0.3 second sooner (plus circuit breaker operating time) so that the relay nearest the fault will operate first to remove the faulted section. See figure 1. Fig. 1 r Relay., t. curve.s - -- -:.::-:.4="---- I- 0.3 Sec. --- -- -- Gen.,[t[t--[}[}--iJiJ--E-- 2 3 "- Fault Power Circuit Breaker Coordination With Adjacent Relays: To assure selective operation, relays in all sections of the protected line should have similar operating curves. Otherwise, curves may intercept, resulting in incorrect relay operation. See figure 2. Fig. 2 Coordinated Mis-Matched //-:.-:?/ Relay Tap Range: Magnitude of fault current available at a given location is usually determined by system studies. Tap range selection depends on the fault current as seen by the relay, which is determined by the current transformer ratio and its operating characteristics under fault conditions. Selector Guide Relay Type CO-2 CO-5 CO-6 CO-7 CO-8 CO-9 CO-11 Curve Short Long Definite Moderately Very Extremely Comparative Operating CD 0.47 Sec. 25 Sec. 2 Sec. 2.48 Sec. 2.52 Sec. 1.53 Sec. 0.8 Sec. Basic Application II II Differential protection of bus or generators where restraint windings are not required, Straight overcurrent protection where short operating time is necessary. Motor locked rotor protection. Long time setting prevents tripping due to motor starting currents. characteristic provides faster tripping at higher currents. For use where generating capacity and fault currents vary over a wide range. Relay has fixed operating time (per time dial setting) from approximately 10 to 20 times tap current, most useful where no coordination is required with downstream devices. Overcurrent phase and/or ground fault detection on transmission or feeder lines where moderate changes in generating capacity occur, or on parallel lines where one line may be called on to carry both loads. Relay approaches definite time characteristics at high currents, allowing wide changes in fault current magnitude with little change in operating time. Phase and/or ground fault detection of subtransmission lines or feeders, Also supplied as primary protection or back-up for other relays. Wide range in time lever settings and slope of curves facilitate coordination and assure selective operation. Degree of inverseness required is determined by fault current magnitude, operating time desired, and the characteristics of nearby relays on the system. Used on feeder circuit breakers which must coordinate with main and branch line sectionalizing fuses. Also used where long time delay is required for overload, such as where feeder is energized after extended outage. CD Values shown are with #10 time dial setting, and with 10 times tap value current applied. Ac or D Trip Circuit: Where a dc control source (24 to 250 volts) is available, circuit closing relays are used. If dc is not available, circuit opening relays are used with ac tripping, using the output of a current transformer to energize the circuit breaker trip coil. Under normal conditions, the normally closed contacts of the relay shunt the breaker trip coil. High Speed Short Circuit Fault Protection: Relays equipped with instantaneous overcurrent lit or ITH units provide instantaneous overcurrent tripping, in addition to tripping with time delay on moderate overloads. September, 1990

II II Construction A main tapped coil is placed on the center leg of an "E" type laminated structure. This produces a flux which divides and returns through the two outer legs. A shading coil on the left leg creates an out-of-phase flux which reacts with current induced in the disc by the main coil flux in the air gap to cause disc rotation in the contact-closing direction. Types CO-2 and CO-11 relays are similar in electromagnet construction except that both outer legs have windings to produce the necessary out-of-phase fluxes required for contact-closing rotational torque. G) Unit Tap Block Instantaneous Unit Tap Block Tap Screws @ Magnetic Plugs May be screwed in or out of the magnetic circuit to control saturation and adjust calibration at high currents. A damping magnet and spring adjustment permit calibration at low currents. Dial Indicates starting position of the moving contact over a 2700 range. Indexes from 'i2 (minimum time) to 11 (maximum time). Stationary Contact Made of pure silver. Will close 30 amperes at 250 volts dc. Has sufficient wipe to assure positive contact. In fast breaker reclosing schemes which require quick-opening relay contacts, the metal plate is reversed, holding the stationary contact fixed against the back-stop. On double-trip relays, adjustment of %4' contact follow (or wipe) is obtained by use of a vernier adjusting screw on the stationary contact plate. (/) Moving Contact Also made of pure silver, the moving contact is clamped to the insulated section of the disc shaft. Electrical connection is made from the moving contact through a spiral spring to the spring adjuster frame, then to the relay terminal. Moving contacts will close 30 amperes at 250 volts dc. Induction Disc Spiral shaped to compensate for the spring windup which occurs throughout the moving contact travel. Provides accurate pickup at any disc position. A spring adjuster is provided to permit in between tap pickup adjustment when desired. September. 1990 (8)-----111.- Damping Magnet Made of high strength Alnico. Controls relay operating time at low current values. A keeper screw permits micrometer adjustment of the damping magnet without shifting the location of the magnet, and allows the relay to be accurately calibrated at low currents. Descriptive Bulletin ----(9) Page 3

Descriptive Bulletin Page 4 @ Indicating Contactor Switch (lcs) (Partially Disassembled) The de operated Indicating Contactor Switch has a clapper type magnetic armature to which leaf-spring contacts are attached. When the switch is energized, the moving contacts bridge the stationary contacts, completing the trip circuit. The ICS contacts are connected in parallel with the main relay contacts, relieving them of carrying heavy trip currents. During operation, two fingers on the armature deflect a spring, which allows the operation indicator target to drop. The target is orange color and readily visible. Further Information List Prices: PL 41-020 Technical Data: TO 41-025 Instructions: IL 41-100 Renewal Parts: RPD 41-914 Flexitest Case Dimensions: DB 41-076 Contactor Switches: DB 41-081 Other Protective Relays: Application Selector Guide TO 41-016 T f I @ ICS Tap Selection The indicating contactor switch has two taps that provide a pickup setting of 0.2 or 2 amperes. To change taps requires connecting the lead located in front of the tap block to the desired setting by means of a screw connection. When using a 125 or 250 volt dc auxiliary WL auxiliary relay, the 0.2 ampere tap is recommended. The 2.0 ampere tap is used with WL relays on 24 or 48 volt dc circuits. @ Indicating Instantaneous Trip (lit) Used for high speed detection of large fault currents. Construction is similar to that of the Indicating Contactor Switch, except that it is ac operated, and adjustable over the range. Variable pickup is obtained by a core screw adjustment on the top of the unit. When the lit is energized above pickup setting, the target drops. September. 1990

December, 1990 Supersedes TO 41-020, Type Hi-Lo CO on pages 5 and 6, dated November, 1987 Mailed to: E, 0, C/41-100A ABB Power T&D Company Inc. Relay Division Coral Springs, FL Allentown, PA Non-Directional, Single Phase Adjustable Delay Type Hi-Lo CO Relay Overcurrent, Non-Directional, Single-Phase, Non-Torque Controlled, 60 Hertz (Device Number: 51 & 50/51) Descriptive Bulletin 41 102E PageS Type Hi-Lo CO Overcurrent Relays Type Contacts Indicating Current Range Internal Style Case Curve Contactor Amps:Ac Schematic Number Size Switch Instan- Unit taneous UnitllT@ HI-Lo CO-2CD Short Spst 0.212.0.5-2.5 None 5704523 265C195A01@ FT-11 Amp dc 5704523 265C195A05@ 265C195A03 265C195A07@ 265C195A09 265C195A11 Opst.5-2.5 None 5704524 265C195A02 5704524 265C195A06 265C195A04 265C195A08 265C195A10 265C195A12 Spst.5-2.5 None 265C195A41 265C195A45 265C195A43 265C195A47 265C195A49 265C195A51 Hi-Lo CO-5CD Long Spst 0.2/2.0.5-2.5 None 5704523 264C897A01 FT-11 Amp dc 5704523 264C897A05@ 264C897A03 264C897A07@ 264C897A09 264C897A11 Opst.5-2.5 None 5704524 264C897A02 5704524 264C897A06 264C897A04 264C897A08 264C897A10 264C897A12 Spst.5-2.5 None 264C897A41 264C897A45 264C897A43 264C897A47 264C897A49 264C897A51 HI-Lo CO-6CD Oefinite Spst 0.212.0.5-2.5 None 5704523 264C898A01 @ FT-11 Amp dc 5704523 264C898A05@ 264C898A03 264C898A07@ 264C898A09 264C898A11 Opst.5-2.5 None 5704524 264C898A02 5704524 264C898A06 264C898A04 264C898A08 264C898A10 264C898A12 Spst.5-2.5 None 264C898A41 264C898A45 264C898A43 264C898A47 264C898A49 264C898A51 @ Denotes item available from stock. setting. Suitable for dc control voltages up to and including The.f'CS unit may be supplied in place of an ICS unit at no CD 50 Herlz relays and auxiliaries can be supplied at same 250 vons dc. Two current ranges available: additional cost. Specify system voltage rating on order. price. Order "Similar to Style Number... except (1) 0.212.0 amps dc, with tapped coil. 50 Herlz. (2) 1.0 amp dc, without taps. @ ITT: Indicating Instantaneous Trip rated per ranges shown Styles have isolated Indicating Contactor Switch (ICS) and in price tables. Unit is nondirectional, adjustable, and has ITT. when applicable, contact outputs. Rating of ICS unit used in specific types of relays is shown target actuated when coil is energized at or above pickup ICS: Indicating Contactor Switch (dc current operated) hav- in price tables. All other ratings must be negotiated. setting. Unit has a dropout ratio of 65% at minimum setting ing seal in contacts and indicating target which are actuated and 900/0 at maximum setting. when the ICS coil is energized at or above pickup current When ac current is necessary in a control trip circuit, the ICS unit can be replaced by an ACS unit.

Descriptive Bulletin Page 6 Type Hi-Lo CO Relay Overcurrent, Non-Directional, Single-Phase, Non-Torque Controlled, 60 Hertz, Continued Type Contacts Indicating Current Range Curve Contactor Amps: Ac Switch@ Instan- Unit taneous UnitllT@ HI-Lo CO-7<D Moderately Spst 0.2/2.0.5-2.5 None Amp dc Opst.5-2.5 None Spst.5-2.5 None HI-Lo CO-8<D Spst 0.2/2.0.5-2.5 None Amp dc Opst.5-2.5 None Spst.5-2.5 None HI-Lo CO-g<D Very Spst 0.2/2.0.5-2.5 None Amp dc Opst.5-2.5 None Spst.5-2.5 None Denotes item available from stock. Rating of ICS unit used in specific types of relays is shown <D 50 Hertz relays and auxiliaries can be supplied at same in price tables. All other ratings must be negotiated. price. Order "Similar to Style Number..... except 50 Hertz". When ac current is necessary in a control trip circuit, the Styles have isolated Indicating Contactor Switch (ICS) and ICS unit can be replaced by an ACS unit. ITT, when applicable, contact outputs. @ ICS: Indicating Contactor Switch (dc current operated) hav- The ACS unit may be supplied in place of an ICS unit at no ing seal in contacts and indicating target which are actuated additional cost. Specify system voltage rating on order. when the ICS coil is energized at or above pickup current setting. Suitable for dc control voltages up to and including @ ITT: Indicating Instantaneous Trip rated per ranges shown 250 volts dc. Two current ranges available: in price tables. Unit is nondirectional, adjustable. and has (1) 0.212.0 amps dc. with tapped coil. target actuated when coil is energized at or above pickup (2) 1.0 amp dc, without taps. setting. Unit has a dropout ratio of 65% at minimum setting and 90% at maximum setting. Internal Style Case Schematic Number Size 5704523 264C899A01 FT-11 5704523 264C899A05 264C899A03 264C899A07 264C899A09 264C899A11 5704524 264C899A02 5704524 264C899A06 264C899A04 264C899A08 264C899A10 264C899A12 264C899A41 264C899A45 264C899A43 264C899A47 264C899A49 264C899A51 5704523 264C900A01 FT-11 5704523 264C900A05 264C900A03 264C900A07 264C900A09 264C900A11 5704524 264C900A02 5704524 264C900A06 264C900A04 264C900A08 264C900A10 264C900A12 264C900A41 264C900A45 264C900A43 264C900A47 264C900A49 264C900A51 5704523 264C901 A01 FT 11 5704523 264C901 A05 264C901 A03 264C901A07 264C901A09 264C901A11 5704524 264C901A02 5704524 264C901A06 264C901A04 264C901A08 264C901A10 264C901A12 264C901A41 264C901A45 264C901A43 264C901A47 264C901A49 264C901A51 December, 1990

Type Hi-Lo CO Relay Overcurrent, Non-Directional, Single-Phase, Non-Torque Controlled, 60 Hertz, Continued :,- Type Contacts Indicating Current Range Internal Curve Contactor Amp s -",-,_ : A-" _ C :-c- Schematic Switch@ " Instan- Unit taneous Unit IIT@ HI-Lo CO-11 CD Extremely Spst Opst Spst Denotes item available from stock. CD 50 Hertz relays and auxiliaries can be supplied at same price. Order "Similar to Style Number... except 50 Hertz". Styles have isolated Indicating Contactor Switch (ICS) and ITT, when applicable, contact outputs. @ ICS: Indicating Contactor Switch (dc current operated) hav ing seal in contacts and indicating target which are actuated when the ICS coil is energized at or above pickup current setting. Suitable for dc control voltages up to and including 250 volts dc. Two current ranges available: (1) 0.212.0 amps dc, with tapped coil. (2) 1.0 amp dc, without taps. December, 1990 0.2/2.0 Amp dc.5-2.5 None.5-2.5 None.5-2.5 None Rating of ICS unit used in specific types of relays is shown in price tables. All other ratings must be negotiated. When ae current is necessary in a control trip circuit, the ICS unit can be replaced by an ACS unit. The ACS unit may be supplied in place of an ICS unit at no additional cost. Specify system voltage rating on order. @ ITT: Indicating Instantaneous Trip rated per ranges shown in price tables. Unit is nondirectional, adjustable, and has target actuated when coil is energized at or above pickup setting. Unit has a dropout ratio of 65% at minimum setting and 90% at maximum setting. 5704523 5704523 5704524 5704524 Style Number 265C047A01 265C047A05 265C047A03 265C047A07 265C047A09 265C047A11 265C047A02 265C047A06 265C047A04 265C047A08 265C047A10 265C047A12 265C047A41 265C047A45 265C047A43 265C047A47 265C047A49 265C047A51 Descriptive Bul/etin Page 7 Case Size FT-11