Online data sheet S71 E 1217512 S7
S71 E 1217512 S7 A B C D E F C US Detailed technical data Technical specifications Description Ordering information Type Part no. S71 E 1217512 1217512 Other models and accessories www.sick.com/s7 19 rack enclosure with 3 rack units, for integration in cabinets H I J K L M N O P Q R S T Measured values CO, NO, O 2, SO 2 Performance-tested measurands CO, NO, O 2, SO 2 Maximum number of measurands 4 Measurement principles Gas flow rate Measuring ranges Certified measuring ranges Response time (t 9 ) Sensitivity drift Zero point drift Sample gas temperature Required operating range: CO SO 2 NO O 2 CO NO O 2 SO 2 MULTOR analyzer module OXOR-E analyzer module MULTOR analyzer module OXOR-E analyzer module NDIR spectroscopy, electrochemical cell 5 l/h... 1 l/h 3 l/h... 6 l/h... 2 mg/m³ /... 2, mg/m³... 25 mg/m³ /... 2,5 mg/m³... 25 mg/m³ /... 2,5 mg/m³... 1 Vol.-% /... 25 Vol.-%... 2 mg/m³... 25 mg/m³... 25 Vol.-%... 25 mg/m³ MULTOR analyzer module: 25 s At 6 l/h, depending on cuvette length, gas flow and number of measuring components OXOR-E analyzer module: 2 s Typical at 6 l/h, depending on gas flow 1 %: of measuring range full scale per week 1 %: of measuring range full scale per week 1 %: of smallest measuring range per week 2 %: of smallest measuring range per month 2 GAS ANALYZERS SICK Online data sheet 218-8-1 17:2:34 Subject to change without notice
S71 E 1217512 S7 Analyzer inlet: C... +45 C Process pressure Hosed gas lines: Process gas humidity Dust load Ambient temperature Storage temperature Ambient pressure Geographical altitude Ambient humidity Conformities Electrical safety Enclosure rating Analog outputs Digital outputs Digital inputs Modbus Type of fieldbus integration Indication Operation Menu languages Dimensions (W x H x D) Weight 2 hpa... 3 hpa Non-condensing Free of dust and aerosols +5 C... +45 C 2 C... +7 C 7 hpa... 1,2 hpa 2, m (above mean sea level) 95 % Relative humidity; non-condensing Approved for plants requiring approval 21/8/EC (13. BImSchV) 2/76/EC (17. BImSchV) 27.BImSchV TA-Luft (Prevention of Air Pollution) EN 14181 CE IP2 4 outputs: /4... 2 ma, 5 Ω 8 relay contacts: Three relay outputs preset for failure, service and maintenance 8 Open collector outputs: Freely adjustable 8 optical coupler inputs: Electrically isolated; freely programmable RTU RS-232 LC display Menu-driven operation via LC-display and membrane keyboard German, English, French, Italian, Dutch, Polish, Swedish, Spanish 483 mm x 132.5 mm x 39 mm For details see dimensional drawings 483 mm x 132.5 mm x 39 mm (for details see dimensional drawings) 1 kg... 2 kg Depending on configuration 218-8-1 17:2:34 Online data sheet Subject to change without notice GAS ANALYZERS SICK 3
S71 E 1217512 S7 A B C D E F H I J K L M N O P Q R S T Material in contact with media Power supply Sample gas connections Corrective functions Integrated components Classifications Voltage Frequency Power consumption Viton B, PVDF, CaF 2, gold, Aluminum 1 V AC / 115 V AC / 23 V AC 48... 62 Hz 15 W Depending on system configuration PVDF bulkhead fitting ECl@ss 5. 271532 ECl@ss 5.1.4 271532 ECl@ss 6. 271532 ECl@ss 6.2 271532 ECl@ss 7. 271532 ECl@ss 8. 271532 ECl@ss 8.1 271532 ECl@ss 9. 271532 ETIM 5. ETIM 6. Automatic testing and adjustment with test gases Manual adjustment with test gases MULTOR analyzer module OXOR-E analyzer module PVDF bulkhead fitting EC119 EC119 UNSPSC 16.91 4111546 4 GAS ANALYZERS SICK Online data sheet 218-8-1 17:2:34 Subject to change without notice
Function Service Alarm Esc Help Enter S71 E 1217512 S7 Dimensional drawing (Dimensions in mm (inch)) S71 design 483 (19.) 112 (4.41) 82 (3.23) 52 (2.5) 22 (.87) 132.5 (5.22) 7 8 9 4 5 6 1 2 3 115 (4.53) 39 (15.35) 375 (14.76) 35 (13.78) 42 (1.65) 1 1. sample gas inlet 2 Exhaust gas outlet 3 2. sample gas inlet 4 3. sample gas inlet 218-8-1 17:2:34 Online data sheet Subject to change without notice GAS ANALYZERS SICK 5
S71 E 1217512 S7 A B C D E F S721 Ex design 3 (11.81) 26 (1.24) 22 (8.66) 185 (7.28) 215 (8.46) 8 (3.15) 17 (6.69) 22 (8.66) 3 (1.18) 4 (1.57) 9 (3.54) H I J K L M N O P Q R S T 21 (8.27) 95 (3.74) 1 1. sample gas inlet 2 Exhaust gas outlet 3 2. sample gas inlet 4 3. sample gas inlet 5 Purge gas inlet 6 Purge gas outlet 4 (15.75) 3 (1.18) Ø 48 (18.9) 546 (21.5) 596 (23.46) 396 (15.59) 18 x 24 (.71 x.94) 6 GAS ANALYZERS SICK Online data sheet 218-8-1 17:2:34 Subject to change without notice
S71 E 1217512 S7 S72 Ex design 18 (7.9) 14 (5.51) 276 (1.87) 58 (2.28) 148 (5.83) 168 (6.61) 198 (7.8) 198 (7.8) 3 (11.81) 27 (1.63) 3 (1.18) 4 (1.57) 9 (3.54) 178 (7.1) 73 (2.87) 3 (1.18) Ø 36 (14.17) 43 (16.93) 48 (18.9) 18 x 24 (.71 x.94) 1 1. sample gas inlet 2 Exhaust gas outlet 3 2. sample gas inlet 4 3. sample gas inlet 5 Purge gas inlet 6 Purge gas outlet 218-8-1 17:2:34 Online data sheet Subject to change without notice GAS ANALYZERS SICK 7
Function Service Alarm Esc Help Enter S71 E 1217512 S7 A B C D E F S715 design 28 (11.2) 26 (1.24) 29 (11.42) 32 (12.6) 35 (13.78) 554 (21.81) 53 (2.87) 5 (19.69) 42 (1.65) 1.5 (.41) 2 (.79) 442 (17.4) 45 (1.77) H I J K L M N O P Q R S T 28 (1.1) 6 (2.36) 92 (3.62) 124 (4.88) 1 1. sample gas inlet 2 Exhaust gas outlet 3 2. sample gas inlet 4 3. sample gas inlet 5 Purge gas inlet 6 Purge gas outlet 469 (18.46) 425 (16.73) 415 (16.34) 357 (14.6) 7 8 9 4 5 6 1 2 3 385 (15.16) 27 (1.63) 25 (8.7) 7 (2.76) 35 (1.38) 8 GAS ANALYZERS SICK Online data sheet 218-8-1 17:2:34 Subject to change without notice
132.5 (5.22) Function Service Alarm Esc Help Enter Esc Help Enter 115 (4.53) S71 E 1217512 S7 S71 and S711 design 483 (19.) 112 (4.41) 82 (3.23) 52 (2.5) 22 (.87) 7 8 9 4 5 6 1 2 3 39 (15.35) 375 (14.76) 35 (13.78) 42 (1.65) S71 29 (11.42) 275 (1.83) 25 (9.84) S711 1 1. sample gas inlet 2 Exhaust gas outlet 3 2. sample gas inlet 4 3. sample gas inlet Display and keyboard for S72 Ex and S721 Ex design 35 (12.1) 192 (7.56) 265 (1.43) 233 (9.17) 197 (7.76) L 2 m (6.56 ft) Ø 13 (.51) 7 8 9 4 5 6 1 2 3 12 (4.72) 1 (.39) 11 (4.33) 218-8-1 17:2:34 Online data sheet Subject to change without notice GAS ANALYZERS SICK 9
Online data sheet SICK at a glance SICK is one of the leading manufacturers of intelligent sensors and sensor solutions for industrial applications. A unique range of products and services creates the perfect basis for controlling processes securely and efficiently, protecting individuals from accidents and preventing damage to the environment. We have extensive experience in a wide range of industries and understand their processes and requirements. With intelligent sensors, we can deliver exactly what our customers need. In application centers in Europe, Asia and North America, system solutions are tested and optimized in accordance with customer specifications. All this makes us a reliable supplier and development partner. Comprehensive services complete our offering: SICK LifeTime Services provide support throughout the machine life cycle and ensure safety and productivity. For us, that is Sensor Intelligence. Worldwide presence: Contacts and other locations www.sick.com SICK AG Waldkirch Germany www.sick.com