Vol. l. Empty wt. kg. Dia. Vol l. Empty wt. Dia.

Similar documents
Table 1. Table 2. Table 3: Toxicology/Environmental FM-200 (UL/FM) 14A-07H SECTION 1 - INTRODUCTION. Agent Physical Properties FM-200

HEAD VALVE. Model No.: NF 40/600V, NF 40/360V DESCRIPTION

Solenoid valves VZWM-L, NPT

Component Sheet Library

ARGONITE Fire Protection Systems

BRONZE ZEUS PNEUMATIC ANGLE-SEAT VALVE

Solenoid valves VZWM-L

Technical Data. Neck Threads: W 28.8 x 1 / 14. Water Capacity: Filling Density: Storage Pressure: Working Pressure: Test pressure: Weight (Empty):

ZEUS type BRONZE PNEUMATIC ACTUATED VALVE

HPCO 2. Fire Extinguishing System

STAINLESS STEEL ARES PNEUMATIC ANGLE-SEAT VALVE

PNEUMATICALLY ACTUATED 2-WAY

Special valves. Logic components AND/OR Timer 2/2 way screw-in valves Miniature screw-in pressure regulators Relief valves

S v S e r i e s F M f i r e e x t i n g u i s h i n g s y s t e m

2/2 Pressure operated valves

With regards to safety it is not necessary to check for correct operation.

ZEUS type BRONZE PNEUMATIC ACTUATED VALVE. Model/Ref:

485 - NC NO/DA DN

CATALOG. Actuated Diaphragm Valve DN PVC-U / PVC-C / PP-H / PVDF / ABS SMART IN FLOW CONTROL.

connection solutions in stainless steel

Solenoid valves VZWM-L

Praher S4 Ball Valve. manual valves. Materials. Sizes. Pressure Rating. Features. Connections. Valve Dimensions. Actuation.

Praher S4 Ball Valve. manual valves. Materials. Sizes. Pressure Rating. Features. Connections. Valve Dimensions. Actuation.

S60 PARTS LIST AND DRAWINGS

APV VALVES. Zephyr Valve Series 4 - Control Unit FREEPHONE: SERIES IV ZEPHYR VALVE

VALVES WITH SA03 ELECTRIC ACTUATOR

CONTROLS. Bray Pneumatic Actuators & Accessories. Technical Manual. A Division of BRAY INTERNATIONAL, Inc.

2/ VDMA (ISO ) 5/2-5/3-way CC CO CP. CATALOGUE > Release 8.8 CONTROL > Series 7 valves and solenoid valves GENERAL DATA

ONE TOUCH FITTINGS Series WP2

COILS, CONNECTORS, SOLENOID VALVES

Type 2000, 2002, 2012

Worldwide Contacts.

TECHNICAL DATA 1-1/2 (dn40)

Technical Data. UL Listing is based on the following criteria:

II 2GD. xxxx. Westlock 2200 Series Quantum - ATEX certified Installation & Operating Instructions

Valves and Solenoid valves Series 7

Technical Data Sheet SEVO 1230 Clean Agent Cylinders

DCE 100 Series Dust Filter

BR 26d Ball valve. Stainless Steel. Application: Versions: Special versions:

3/2-way Solenoid Valve for pneumatics

VKD DN PP-H. DUAL BLOCK 2-way ball valve

3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve

Manufacturer of Industrial Valves a n d R e l e v a n t E q u i p m e n t. Tilting Disk Check Valves with Counter Weight.

PRM2-06. Functional Description HA /2014. Proportional Directional Control Valves. Replaces HA /2013. Size 06 p max 350 bar Q max 40 L/min

Fittings Metal Push-To- Connect Fittings. We make things MOVE

2/2-way Solenoid Valve for liquids and gases

VE4000 & VE5000 SERIES

Pilot Operated Directional Control Valves Series D31DW, D41VW - D111VW

Accessories Series PSB. Specifications

VALVES ISO 5599/1, SERIES IPV-ISV

Front panel valves SV

Electromagnetic Industries LLP

TCU Flushing Manifold and RTD Installation

ANGLE SEAT AIR ACTUATED VALVES 2 Way (2/2)

Pressure and Temperature Switches

Mounting and operating instructions EB 5801 EN. Electric Actuators Type 5801 (Rotary Actuator) Type 5802 (Linear Actuator)

Cylinder Valve Assembly Series

Manual pneumatic operated valves for fixed installations, CO2 and inert gases. Series B0430

Transmitters: Relay Valve VR4151/4152

1/2" AIR DRIVEN DIAPHRAGM PUMP

Air Operated 3 Way Brass Ball Valve

BS 2,7-6,7. Steel Containers with Differential Pressure Valve for the CLEAN AGENT FS 49 C2 Extinguishing Agent. Optional

Model DV-5 Deluge Valve, Diaphragm Style, 1-1/2 thru 8 Inch (DN40 thru DN200), Deluge System Electric Actuation

SOLENOID VALVES AND PNEUMATIC VALVES

The Original Seat Valve

DELUGE VALVE MODEL: SD-DVA TECHNICAL DATA : VALVE OPERATION TRIM DESCRIPTION DESCRIPTION PRESSURE THREADED OPENING

HS6B Series Subminiature Interlock Switch

Air Operated 3 Way Stainless Steel Ball Valve

short name: 3WL.IG* technical product sheet created :57 1/6 3-way ball valve F/F PN 63 with pneumatic actuator hard anodized aluminum

Directional Control Valve Series 4D01 (DENISON)

Due to changed market conditions and cost changes on a range of products we have to adjust gross prices for the parts affected.

Pilot-Operated Directional Control Valves Series D3 - D11

EVI 5 S13 Solenoid System

Compact System NRGS 11-2 NRGS Original Installation Instructions English

FLOW SWITCHES AND COMBINATION CONTROLS

Zip FlushMaster Surface mounted sensor

TS93 EMF T/PT/TDE. Surface applied door closer

Using a 4mm pin punch ( ) drive Trigger Pin 40 out and remove Trigger Assembly 39.

SERVICE MANUAL. Koala

Economy Air Operated Brass Ball Valve

This is trial version

Cable resistance thermometer Model TR40

HS1E Series Full Size Solenoid Locking Switches

ABV21i and ABV40i Air Actuated Boiler Blowdown Valves

Our new range of electromechanical pressure switches with fixed setting are compact, light and easy to install.

FIT-2. Inch. Ø Â" to Ë" O/D tube

CEGA SYSTEMS BY GREGGERSEN

Standard screw fittings Brass Art. No to

Group 16. Fittings Brass - Galvanized, AISI Pneumatics

DB4604 GMR-SD and GMR40-SD Disc Brake Caliper - Spring Applied, Air Released

SRG LPG Liquid Service/Offtake Valve Type /

Engineering Data. Assembly Length. How to Determine Correct Assembly Length

HYDRAULIC BREAKER HAMMER HB 50 J HAMMER HB 50 L HAMMER HB 50 U

5/2-way monostable/bistable - 5/3 CC, CO, CP With outlets on the body - For individual or manifold assembly Size 10,5 mm

FLUID POWER FLUID POWER EQUIPMENT TUTORIAL PIPE WORK. This work covers part of outcome 2 of the Edexcel standard module:

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies

ARM1000/2000. Standard Specifications

5.0 MPa Pilot Operated 2/3 Port Solenoid Valve & Check Valve

GW MK3 DELUGE VALVE HYDRAULIC & PNEUMATIC SPARES 100mm (4 ) 150mm (6 ) 200mm (8 )

AUTO STAR with central connector M12x1

Transcription:

Container Assemblies and Connections Multiple Part Numbers Container Assemblies and Connections ISS CG 2 25 bar Container Assemblies Assy Part no. Container Assembly Valve Empty wt. kg Vol. l Dia. Cont. Spacing Outlet height Hose length Manifold height NF2201502*B 15 litre 25bar 33 19.5 15 254 314 453 500 NA 9254 NF2203020*N 30 litre 25bar 33 34 30 300 360 604 500 1160 9300 Bracket NF2203020*B 30 litre 25bar 33 28.5 30 254 314 773 500 1325 9254 NF2205020*N 50 litre 25bar 33 45 50 300 360 899 500 1455 9300 NF2205020*B 50 litre 25bar 33 42 50 324 384 809 500 1358 9324 NF2208020*N 80 litre 25bar 49 63 80 300 360 1364 550 1920 9300 NF2212020*B 120 litre 25bar 49 90.5 120 406 466 1192 550 1810 9406 NF2215020*B 150 litre 25bar 49 105 150 406 466 1432 550 2060 9406 NF2218020*B 180 litre 25bar 49 129 180 462 522 1322 550 1950 9462 42 bar Container Assemblies Assy Part no. Description Valve Empty wt. Vol l Dia. Cont. Spacing Outlet height Hose length Manifold height NF2208040* 80 litre 42bar 33 101 80 270 323 1759 500 2314 9267 NF2215040* 150 litre 42bar 33 170 150 356 410 1912 500 2467 9356 Code *= 0 No integrated solenoid (slave) *= 1 Inc. integrated solenoid (master) Tolerance +/ 10mm on cylinder heights Outlet spacer required on manifolded 180 litre Bracke t

Discharge Valve / Pressure Port Connections Discharge Valve, Pressure Port Connections ISS CG 2 SW 106 B SW 46 M 42 x 1,5 P ilot port 35 72 65 99,5 92 49 2 1/2"- 12 UN 235 G 1/8" B 80 89 2,125"-16 U N Discharge pressure switch and pilot pressure port G1/8 Contents pressure gauge/switch 2 ports M10 special Rupture disc DO NOT REMOVE 3"-12 U N Discharge pressure switch and pilot pressure: Use this port to actuate additional discharge valves and or the Discharge pressure switch. Use discharge pressure switch NF280210A or Pilot hose NF271560 Contents pressure gauge/switch: 2 ports are provided on either side of the valve. Either or both may be used to connect Pressure gauge NF284004 or pressure switches which include a pressure gauge NF285012 (25bar systems) or NF285014 (42bar systems). Access is via a hexagon socketed plug. Screw the gauge/switch fully in and unscrew a maximum of 1 turn to orientate the gauge. Note, screwing in the gauge/switch opens an internal check valve which allows pressure to the device. Unscrewing the device closes the check valve to allow the exchange or removal of the gauge/switch. Refit the plug after removal. Safety rupture disc. Every valve is fitted with a safety rupture disc to protect the pressure vessel from over pressure. This port must not be tampered with.

Actuation Options Actuation Options ISS CG 2 * Note: Integral Solenoid cannot be fitted after the container is filled. Life of Actuators The life of all actuators is indefinite. Recommended maintenance: Visually check for corrosion and damage every 6 months Replace Integral Solenoid core every 10 years. V20140501

Pneumatic / Manual Actuator NF26030 Pneumatic / Manual Actuator ISS CG 2 Manual Actuation Force <150N Working Temperature 20 to 50 Minimum actuation pressure 16 Bar Connect the tripping mechanism to the valve using the M42 x 1.5 connecting thread with a torque of 50+0/ 15 Nm. Screw fully down Connect the Pilot line using the G1/8 with PTFE tape To use only in combination with a solenoid actuator Refer to ISS CG 2 227 Manual before assembling to system

Pneumatic Slave Actuation Pneumatic Slave Actuation ISS CG 2 Last actuator fitted with the Plug taken from the Master Valve Pilot connection Pneumatic Actuator NF26020 Pilot Hose NF271560 (560mm) Use longer hose NF271300 (1300mm) between a large master container and a smaller slave container Hoses are provided with appropriate swivel connections Manual/Pneumatic Actuator NF26030 Connection G1/8 Fit Discharge Pressure Switch NF280210 using Hose NF271560 to last valve or the discharge manifold Extended pilot operation The LPCB Approval included for the use of 4 pilot hoses and 4 pneumatic actuators. For multiple container modular use our own testing has shown full operation of all the actuators with a pilot tube from the master valve of 30m, 10 Pneumatic Actuators and 10 Pilot hoses. (Tube 4mm internal diameter gave a 0.75 s delay between the opening of the master valve to the operation of the last actuator). Valves shown with the pressure gauges removed for clarity. Drawings not to scale.

Container Discharge Hoses Container Discharge Hoses ISS CG 2 Hose Assembly Min. bend radius Dimension A Dimension B Valve Fitting C JIC Fitting D ISO 7 1* Min. through bore NF2333500 500 500 77 1 7/8 x 12 R 1 1/2 33.3 NF2349550 635 550 99 2 1/2 x12 R 2 44.5 *Connect to Check Valve or discharge pipe work before attaching to the discharge valve with the swivel connection. Note: Maximum bend between centre lines of fittings 20 degrees

DN49 JIC Outlet Adapter NF234980 49mm Discharge Outlet Spacer ISS CG 2 Material Steel Finish Zinc Plated Use only with ISS CG 2 Clean Agent Chemical System 180 Litre Cylinders when using a discharge hose V20140501

Container Valve Low Pressure Switch NF285022 Container Valve Low Pressure Switch (option) ISS CG 2

Discharge Pressure Switch NF280210A Discharge Pressure Switch (inc. Hose) ISS CG 2 Discharge pressure switch Use to confirm the discharge of a system. The switch is wall mounted and connected to either the Discharge pressure switch and pilot pressure port on the discharge valve, the discharge manifold or discharge pipe work using the pilot hose NF280211. Specification: Pressure connection Material wetted parts Switch housing Electrical Set pressure Mounting bracket G1/4 (1/4 BSP male parallel) Brass with beryllium copper diaphragm Connection M20x1.5. Ingress protected to IP65 SPDT Microswitch 10A 250V 50Hz, 1A 30V dc inductive loads. 2 bar rising. Latching manual reset by top mounted button. Included.

Entrence Label - Cutation - NF290221 Manual Relase Lapel - NF290121 Entrance Label - Caution A Entrance labelis required at each entrance to the risk to advise personnel that they are entering a protected area. Manual Release Label A notice should be located at each manual release position. NF290121 NF290221 Technical Information Technical Information Material Finish Overall Size: 2 mm (0.0 ) Craylon Gloss, scratch resistant 215mm (L) x 215mm Material Finish Overall Size: 2 mm (0.0 in) Craylon Gloss, scratch resistant 215mm (L) x 8mm (W) Weight: 0.02 kg (0.0 lbs) Weight: 0.011 kg (0.024 lbs)

Discharge Nozzles Multiple Part Numbers Discharge Nozzles 180 & 360 Degree Coverage ISS CG 2 Nozzle Information Length, mm Dimension 1/2" DN15 3/4" DN20 1" DN25 1 1/4" DN32 1 1/2" DN40 2" DN50 A 34 41 51 63 71 103 ZØ 24 32 40 50 60* 75* Connection 1/2" BSP 3/4" BSP 1" BSP 1 ¼ BSP 1 ½ BSP 2" BSP Part Number 1800 NF 251521 NF 252021 NF 252521 NF 253221 NF 254021 NF 255021 Part Number 3600 NF 251522 NF 252022 NF 252522 NF 253222 NF 254022 NF 255022