Manual Turbine Flow Meters HM Series

Similar documents
Technical Datasheet HM Series Turbine Flow Meters Certified according to DIN EN ISO 9001

Technical Datasheet. HM U Series. Turbine Flow Meters. for lubricating liquids

Technical Datasheet. HM R Series. Turbine Flow Meters. with Female Inch Threads

Technical Datasheet. HM AC Series. Turbine Flow Meters. for High Pressure Applications up to 1,400 bar

HM...E. Turbine Flow Meters with Ermeto Fittings. Technical Datasheet

HM...TRI. Turbine Flow Meters (Tri-Clamp) for pharmaceutical Applications. Technical Datasheet

HM...TC-R. Turbine Flow Meters for Solvents and Di-Water. Technical Datasheet

Technical Datasheet. ZHM CT Series. Gear Flow Meters in Cartridge Design.

Certified according to DIN EN ISO Technical Datasheet. HM Series. Turbine Flow Meters

ZHM Series. Gear Flow Meter OVERVIEW PRINCIPLE AND DESIGN APPLICATIONS PICKUPS AND AMPLIFIERS FEATURES

Axial Turbine Flow Sensor Series Turbotron VTH 25 / VTI 25 / VTM 25

KEM Automotive Test Stands DESIGN PRODUCTION DISTRIBUTION

KEM - Your Partner for Flow Measurement Technologies

RUN ACCUM. TOTAL STOP BAT LOW HIGH

INLINE Flow sensor for hazardous area II 1 G/D - II 2 D - II 3 GD - I M1

FTB 372 Series Axial Turbine Flow Meter

Certified according to DIN EN ISO Technical Datasheet LFM 10. Micro Flow Meter

GPM Hydraulic Flow Meter User Manual

Operating Instructions. Angle Seat Control Valve. Type 7020

Satellite photo of cloud vortices caused by a mountain (Courtesy of our friends at NASA) tekvorx Operation Showing Simplified Construction

Magnetic-inductive flow meter for hazardous areas

Operating Instructions. Pneumatic Control Valve Low Temperature. Type Series GS3

MZ Instruction manual Mode d emploi Betriebsanleitung Istruzioni d uso Manual de instrucciones Installatie voorschrift

Flow Sensors & Instruments

Steering column and sensor

Model TUR-200D Turbine Flowmeter

Flow limiter SP/SMB3 Flow limiter SP/SMB6

Turbine meter. Operating manual. A-EN Rev.E 11/2013. Page 1 of 16

RPFS. ROTA PULSE FLOW SENSOR (Slip Insertion Paddlewheel) DATASHEET FEATURES

PA - Turbine Flowmeter Range

FLUXI 2000/TZ Instruction manual Mode d emploi Betriebsanleitung Istruzioni d uso Manual de instrucciones Installatie voorschrift

INSTALLATION AND OPERATION

BARTON 7400 Precision Gas Turbine Flow Meters

Fluxi 2000/TZ Turbine Gas Meter

Volumeter TRZ 03-K PRODUCT INFORMATION. Reliable Measurements of Gas

Electromagnetic Flow Monitor magphant

ORIMAS Mass Flowmeter

Differential Pressure Gauges Cryo Gauge Model , Cu-alloy Model , Stainless Steel Series

VFM4070C SWIRLMAX. Vortex Flowmeter OUTLINE FEATURES OPERATING PRINCIPLE STANDARED SPECIFICATION. General Specification. Sensor Specification

Intrinsically safe presure transmitters for hazardous environments Type MBS 4201, MBS 4251, MBS 4701 and MBS Technical brochure

Turbine Flow Meter Range

Installation and Setting-Up Instructions Spare Parts List

MX06 - MX100 OVAL GEAR FLOWMETER SERIES APPROVED FOR USE IN HAZARDOUS AREAS

Turbine flowmeters Series TM

Compact Heat Meters. Features. -A Pulsed output. -B M-Bus output. Accessories. UK Sales Tel: International Tel:

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

Datasheet PDCSY-MW-CHM. Technical Overview. Features. Product warranty and total quality commitment. General Information.

RMG Meßtechnik GmbH. Publication No E

FUNDAMENTALS OF INSERTION TURBINE METERS Les Bottoms Thermo Electron Corporation, Flow Systems

Condensate Drain Valve AK 45. Original Installation Instructions English

Quantometer MZ. Description

CORROSION RESISTANT IN LINE FLOW SWITCHES

FLENDER ZAPEX couplings. Type ZWT. Operating instructions BA 3505 EN 10/2011. FLENDER couplings

Type 3761 Pneumatic or Electropneumatic Positioner for Rotary Actuators. Fig. 1 Type 3761 Positioner. Mounting and Operating Instructions EB 8386 EN

Insertion turbine INSTRUCTION SHEET. TECHNICAL PRODUCT

Electropneumatic Converters i/p Converters Type 6111 Mounting and Operating Instructions EB 6111 EN

VMH. www. delta-elektrogas.com. Safety shut off valves for gas with hydraulic actuator DN65 DN200 EE

Type 2511/12. Type Type 2030 Cable plug. ASI cable plug. Dosing control. General technical data Orifice Type 6518

F-4600 INLINE ULTRASONIC FLOW METER Installation and Operation Guide

Freefall metal detection system Vistus with separator FL

Sanitary Turbine Flow Meter - TA3 Installation, Operating & Maintenance Manual

Ports. Dr. Breit GmbH Carl-Zeiss-Straße 25 D Heiligenhaus phone-contact:

STEEMCO-MAS Flowmeter for Steam

TR-QS Wafer-Style Turbine Flow Meters Installation, Operating & Maintenance Manual

Freefall metal detection system Vistus with separator EC

INSTRUCTION MANUAL INDUSTRIAL PERISTALTIC PUMPS MODEL RBT-70

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

LEVEL AND FLOW MEASUREMENT WS131 FLOW METER USER MANUAL.

Level Measurement based on Archimedes Principle. Device Description

Certified according to DIN EN ISO Technical Datasheet. ZHM Series. Gear Flow Meter

Differential Assembly Remove and Install ( ) Remove. Rear Axle. Special Tools. Workshop Equipment Transmission jack Angle gauge

MX-SERIES OVAL GEAR FLOW METERS

MAXIMATOR Compressors DLE 5

Instructions Manual. Target Disk Flow meter DP-65 / DP-500. Series DP-65 DP-500. instrumentation for fluids

DeZURIK " BAW AWWA BUTTERFLY VALVES WITH EPOXY-RETAINED SEAT

Operating Instructions

MWF+ Application. Types Available. Average temperature sensor. Datasheet

Before first operating the equipment read the whole of these instructions. Safety may be impaired if they are not followed.

Product Data Sheet. Turbine Flow Meter. QuikSert DESCRIPTION INSTALLATION FEATURES REPAIR KITS

Solenoid Operator 0516 / 1216

Volumeter. RMG Meßtechnik GmbH. Publication No E

AKF10+ Application. Types Available. Duct-/Immersion temperature sensor. Datasheet

Spin-on filter according to Bosch Rexroth standard: Type 50 SL 30 to 80D. Features. Contents. RE Edition:

Certified according to DIN EN ISO Technical Datasheet. HM Series. Turbine Flow Meters

Installation and Operating Instructions for EAS -NC clutch Type 45_. _. _ Sizes 02 and 03

VML. elektrogas.com. Safety solenoid valves for gas Slow opening and fast closing type DN10 DN80 EE

OVAL GEAR FLOWMETER ELECTRONIC MODEL 019 / ¾

1/2-2 INSTALLATION INSTRUCTIONS

Operating instructions Binary level sensor LMT /00 06/2011

Disassembly. 1 Pull off the QUIK-LOK cable from the machine.

INSTALLATION AND MAINTENANCE INSTRUCTIONS For Chemline EC & EK Series Characterized Control Valves Sizes 1/2 6

FLOWX3 F3.20 High Pressure Paddlewheel Flow Sensor MAIN FEATURES APPLICATIONS OPERATING PRINCIPLE

Installation, Operating & Maintenance Instructions. Norbro J-Switch FM 00707

Liquid Turbine Flow Meter OwnerÊs Manual

Maintenance Information

Operating Instructions. VEGASWING 61, 63 with oscillator SW E60N (EX)

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

Resistance Thermometers Model TR217, with Spring-Loaded Probe Tip

Magnetic Field Sensor for pneumatic cylinders BIM-UNT-AY1X/S1139

K - Flow Meter with Float

Transcription:

www.kem-kueppers.com info@kem-kueppers.com Manual Turbine Flow Meters HM Series

2 Version Manual-Version HM_M_EN_170101_E002

Index 3 Index 1. GENERAL INFORMATION... 4 1.1. General... 4 1.2. Evaluation... 4 2. INSTALLATION... 5 2.1. Start up... 5 2.2. Installing the Turbine Flow Meter... 5 2.3. Sources of Interference... 6 2.3.1. Turbulence and other flow disturbances... 6 2.3.2. Magnetic fields and similar sources of interference... 6 2.3.3. Gas bubbles in the system... 6 2.3.4. Cavitation... 6 3. MAINTENANCE... 7 3.1. Output signals... 7 3.1.1. Fitting the pickup... 7 3.1.2. Connecting pickups, amplifiers, electronics... 7 3.1.3. For separated versions IF* and VIEG... 7 3.1.4. Ex Protection ATEX 100a... 8 3.2. Spare Parts for Turbine Flow Meters... 8 3.2.1. Two flow rectifiers with bearings... 8 3.2.2. One turbine wheel with shaft... 8 3.3. Disassembly of the Repair Kit... 9 3.4. Assembly or Re-Assembly of the Repair Kit... 9 4. IMPORTANT INFORMATION... 10 4.1. Warranty... 10 4.2. WEEE and RoHs... 10

4 General Information 1. General Information 1.1. General The measuring medium passes through the turbine flow meter in axial direction rotating the wheel. The RPM of the wheel is in proportion to the mean flow velocity. Our pickups in the flow meter detect the RPM of the wheel through the body of the turbine. The output signal of the pickups is an alternating voltage. The frequency of the voltage (pulses per litre) is proportional to the instantaneous flow rate. The voltage is amplified and modified. Pulses per time unit will finally serve the evaluation of measurements (in addition, an analogue signal 4 to 20 ma is available when using the local display unit VTM). The K-factor (calibration factor) of the turbine flow meter defines the exact pulse rate per litre. We calibrate our flow meters to determine their K-Factors. 1.2. Evaluation Among others, our calibration records include these specifications: Max. measuring error referring to the instantaneous flow rate Max./min. frequency with corresponding flow values K-factors for different flow rates Average K-factor valid for the entire flow range Please adjust your evaluation equipment considering the above specifications. The following equation applies: Q = flow rate in ltr. per min F = frequency in Hz K = K-factor in pulses per litre

Installation 5 2. Installation 2.1. Start up Mechanical and electrical installations start up and maintenance shall only be effected by qualified and authorised personnel. Make sure the measuring range of the meter cannot be exceeded by more than 20%. Please purge your pipe system before installing the turbine. Fibrous contamination in particular must not enter the turbine. Turbine s diameter Filtration 3-9 mm 100 micron 9-50 mm 300 micron 50-250 mm 500 micron 2.2. Installing the Turbine Flow Meter Choose a straight part of the pipe for installation in flow direction (arrow). The small turbines HM 9 EP and HM 9 RP must be installed in vertical position with outlet up. Furthermore, a backpressure of ½ m is necessary here. All other turbines will work in every position. However, K-Factors might slightly change horizontal position as we calibrate turbines below 50 mm dia. in a vertical position. NOTE Keep distance from sharp bends, T-pieces, valves, pumps by allowing a sufficient length of straight pipe up- and downstream of the meter. Pipe connections Pipe connections and turbine have to be of identical diameters. When deviations occur due to high-pressure connections the pipe connections should have an internal diameter slightly smaller than the turbine's nominal diameter. Pipe reducers Please use only cone types with an angle of 22 or 30. Gaskets must not protude into the nominal bore diameter.

6 Installation 2.3. Sources of Interference 2.3.1. Turbulence and other flow disturbances close to the meter will falsify measuring results. Under extreme conditions they might also damage the turbine. Laminar flow rectifiers (2.5 x turbine's nominal diameter long) fitted on both sides of the meter will eleminate problems. 2.3.2. Magnetic fields and similar sources of interference Magnetic fields and similar sources of interference close to the meter might affect the pickups. Especially inductive pickups type IF* could react like an antenna. Vibrating pipes can have a resonance effect on the pickups. You may prevent this by: Fitting the pickup properly (see chapter 3.2) to avoid metalic contact of the pickup tip and the bottom of the pickup bore in the turbine body. Fitting anti-vibration joints or flexible pipes before or after the flow rectifiers (see chapter 2.2). 2.3.3. Gas bubbles in the system please ensure that pipes are filled with liquid. Bubbles, air pockets or gas will falsify your measuring results. Turbine flow meters dectect the total volume passing through regardless of whether it is completely liquid or containing gas or air. Meters installed in hazardous areas must only be operated completely filled with measuring medium. 2.3.4. Cavitation (especially with measuring liquidised gases) Always ensure a minimum downstream contra pressure to prevent cavitation: 2x pressure drop of the turbine flow meter + vapour pressure of the measuring medium ------------------------------------------------------------- = minimum downstream static pressure

Maintenance 7 3. Maintenance Adhering to the above instructions, standard turbine flow meters are free of maintenance. Calibration values should be checked after approx. 8,000 hours of permanent operation. 3.1. Output signals 3.1.1. Fitting the pickup This is how you avoid a metalic contact of the pickup tip and the bottom of the pickup bore: Screw in pickup handtight without using force Slacken pickup by a 1/4 turn Tighten lock nut 3.1.2. Connecting pickups, amplifiers, electronics NOTE Please use only screened cables, preferably braidscreen types. 3.1.3. For separated versions IF* and VIEG 2.5 m maximum cable length between pickup and amplifier. Connections are as follows: Pickup/amplifier Pin or terminal connection Application VTE*/P Carrier-Frequency Amplifier VTM* Local Display Unit IF*HT/K Inductive Coil and VIEG Inductive Amplifier pin 1 UB +7 to 29 V DC resistant to interference pin 2 push pull -4 F to 248 F/302 F (-20 C to +120 C/+150 C) pin 3 0 V/mass pin 4 pin 5 open collector open collector (emitter) pin 1 UB +7 to 29 V DC local display unit with pin 2 frequency out 3-wire analogue output -4 F to 248 F/302 F pin 3 0 V (-20 C to +120 C/+150 C) pin 4 -Iout pin 5 pin 6 +Iout shield pins A,C signal high medium temperature terminal 1 up to 240 F/662 F UB +7 to 29 V/DC (+240 C/+350 C) terminal 2 0 V/mass terminal 3 terminal 4 terminal 5 terminal 6 NPN/PNP out active/passive, 2-wire shield IF*HT coil A IF*HT coil C For details refer to separate datasheets for pickups and amplifiers.

8 Maintenance 3.1.4. Ex Protection ATEX 100a KEM electronics are available in Ex-protected design, ATEX 100a Ex II 2 G EEx ia IIC T6/T4, and with the intrinsically safe power supplies type EWS. Turbine flow meters can be operated within Ex zone 1. 3.2. Spare Parts for Turbine Flow Meters Pickups, amplifiers and repair kits are available as spare parts. A repair kit includes: 3.2.1. Two flow rectifiers with bearings located by projections to groove inside the housing. The projections are wedged between spacers (Ermeto turbines) or inlet cones (flange turbines) and a recess in the body. The spacers are fixed by ring nuts (3). Ball bearings inside the rectifier bores absorb the axial forces. 3.2.2. One turbine wheel with shaft the wheel is placed between the rectifiers. The shaft goes inside the bearing holes of the rectifiers. Turbine with Ermeto fittings Turbine with flanges 1 = flow rectifier with bearing 1 = flow rectifier with bearing 2 = spacers 2 = inlet cone 3 = ring nut 3 = ring nut 4 = turbine wheel with shaft 4 = turbine wheel with shaft 5 = ball bearing inside 5 = ball bearing inside 6 = Ermeto fitting 6 = flange

Maintenance 9 3.3. Disassembly of the Repair Kit If you intend to reinstall the old parts, please place them exactly in their original positions later on. Mark the rectifiers and the wheel with a suitable pen to prevent confusion about entry- and outlet- side for re-assembly. 1. Remove the ring nuts With flange-typed meters use a pin wrench With Ermeto-typed meters use a screwdriver With larger nominal sizes please make up a suitable steel sheet tool to unscrew the rings 2. Remove the distance rings (Ermeto turbines) or inlet cones (flange turbines) 3. Pull out the flow rectifiers subsequently from both sides by means of pointed pliers or pincers. Please be careful: The ball bearings must not drop out of the holes. 4. Please purge the turbine housing. Ensure that no sediments remain in the housing. 3.4. Assembly or Re-Assembly of the Repair Kit In case you received a complete a complete spare repair kit from KEM, please consider that a new calibration record is part of delivery. Adjust your instrumentation in accordance with the new record. The rectifiers and the wheel must be mounted in the same position as delivered. Flow directions as indicated by an arrow must be the same on the repair kit and the turbine body. Place»E«-signed parts towards the entry Place»A«-signed parts towards the outlet 1. Insert the flow rectifiers NOTE Please be careful: The ball bearings must not drop out of the holes. 2. Move the spacers into the turbine body and fix them with the ring nuts. 3. Torque for the ring nuts Up to 9 mm dia.: 15 Nm from 9 mm dia. on: 25 Nm from 19 mm dia. on: 35 Nm 4. Test On completed assembly check the meter to tightness and pressure resistance as per EC directive 97/23/EC. The calibration data of the new repair kit are now applicable. Please adjust your evaluation electronics correspondingly.

10 Important Information 4. Important Information 4.1. Warranty KEM warrants material and production for a period of 18 months after installation and start up, max. 24 months from delivery date. 4.2. WEEE and RoHs The unit described herein is not subject to the WEEE directive and the corresponding national laws. At the end of life forward the unit to a specialized recycling company and do not dispose it of as domestic waste. The unit described herein fully complies with the RoHS directive.

Important Information 11 KEM Headquarters Liebigstraße 5 85757 Karlsfeld Deutschland T. +49 8131 59391-0 F. +49 8131 92604 info@kem-kueppers.com KEM Sales Liebigstraße 5 85757 Karlsfeld Deutschland T. +49 8131 59391-100 F. +49 8131 92604 sales@kem-kueppers.com KEM Manufacturing Center Wettzeller Straße 22 93444 Bad Kötzting Deutschland T. +49 9941 9423-0 F. +49 9941 9423-23 production@kem-kueppers.com KEM Service & Repairs Wettzeller Straße 22 93444 Bad Kötzting Deutschland T. +49 9941 9423-37 F. +49 9941 9423-24 service@kem-kueppers.com More distributors and partners can be found at: www.kem-kueppers.com Original KEM document: HM_M_EN_170101_E002 Copyright KEM, Subject to change without notice