List of exemptions from compliance with the Technical Rules granted by Western Power after 1 July 2007

Similar documents
Exemptions currently in force

Western Power s list of exemptions from compliance from Technical Rules granted after 1 July 2007.

DESCRIPTION OF REQUIREMENTS FOR GENERATION SYSTEMS SEEKING TO PROVIDE SYSTEM RESTART SERVICES

Jemena Electricity Networks (Vic) Ltd

Commercial-in-Confidence Ashton Old Baths Financial Model - Detailed Cashflow

Guidelines for connection of generators:

Date Issued: 10 August 2009 Status: ISSUED Review Date: 10 August 2011 Ref: NS5.3 DISTRIBUTED GENERATION TECHNICAL REQUIREMENTS TABLE OF CONTENTS

ISO Rules Part 500 Facilities Division 502 Technical Requirements Section Interconnected Electric System Protection Requirements

COMPARISON OF FIXED & VARIABLE RATES (25 YEARS) CHARTERED BANK ADMINISTERED INTEREST RATES - PRIME BUSINESS*

COMPARISON OF FIXED & VARIABLE RATES (25 YEARS) CHARTERED BANK ADMINISTERED INTEREST RATES - PRIME BUSINESS*

LEGISLATIVE COUNCIL Question on notice. Tuesday, 12 May Hon Robin Chappie to the Leader of the House representing the Minister for Energy.

PSNH INTERCONNECTION REQUEST

A member-consumer with a QF facility shall not participate in the Cooperative s electric heat rate program.

Company Directive STANDARD TECHNIQUE: SD4O/1. Standard HV Connection Arrangements

PID 274 Feasibility Study Report 13.7 MW Distribution Inter-Connection Buras Substation

Research Brief. Impact of higher 25kV fault currents. T873 - October Background. Aims

2018 Annual Progress Report to WECC Pacific Gas and Electric Company

Interconnection System Impact Study Report Request # GI

Guideline for Parallel Grid Exit Point Connection 28/10/2010

TRANSMISSION PLANNING CRITERIA

SP Distribution plc. and XXX

TECHNICAL SPECIFICATION FOR INDEPENDENT POWER PRODUCERS. NB Power Customer Service and Distribution. June 2008

Contents. 1 Introduction. 2. Advisory and Information Systems. 3. Supply. 3.1 Quality of Electric Supply. 3.2 Interference with other Customers

Accidental Islanding of Distribution Systems with Multiple Distributed Generation Units of Various Technologies

Feasibility Study. Shaw Environmental, Inc. 12MW Landfill Gas Generation Interconnection. J.E.D. Solid Waste Management Facility. Holopaw Substation

SA Power Networks Commissioning Witnessing Checklist

Legal Name of the Customer (or, if an individual, individual's name): Name: Contact Person: Mailing Address: Physical Address: City: State: Zip Code:

APPLICATION FOR INSTALLATION OF SMALL SCALE EMBEDDED ELECTRICITY GENERATION

Guide. Services Document No: GD-1401 v1.0. Issue Date: Title: WIND ISLANDING. Previous Date: N/A. Author: Heather Andrew.

APPENDIX I: Description and Functional Specifications for Transmission Facilities Eligible for Competitive Solicitation

Electric Networks/Ina Lehto Updated Original 12/2011

PJM Generator Interconnection Request Queue #R60 Robison Park-Convoy 345kV Impact Study September 2008

RULE 21 GENERATING FACILITY INTERCONNECTION APPLICATION SMUD s Distribution System - (SMUD FORM 2655)

Generator Interconnection Facilities Study For SCE&G Two Combustion Turbine Generators at Hagood

Net +Plus Connection Code

MONTHLY PERFORMANCE DASHBOARD

Feasibility Study Report

MONTHLY PERFORMANCE DASHBOARD

Standards, Procedures and Policies for Grid Connection

Pacific Gas and Electric Company s Revised 2016 Annual Progress

Appendix A2: Technical Requirements for Distributed Generators > 10 kw to be Connected to Kitchener-Wilmot Hydro Inc. s Distribution System

Export limits for Embedded Generators up to 200 kva connected at Low Voltage

ELECTRIC SERVICE RATE SCHEDULES. Effective November 1, 2017

Facilitated Discussion on the Future of the Power Grid

INTERCONNECTION STANDARDS FOR PARALLEL OPERATION OF SMALL-SIZE GENERATING FACILITIES KILOWATTS IN THE STATE OF NEW JERSEY

MONTHLY PERFORMANCE DASHBOARD

Ukujima Photovoltaic Park 400 MW Stable Integration of a 400MW Photovoltaic Farm into the Japanese Power System Challenges and Chances

Emerald Reactive Support Alternative Solution Expressions of interest

Advanced controls of PV for microgrid applications

Enquiry Form (Non-Registered Generator With Capacity less than 5 MW)

Small Generator Interconnection Program Interconnection Technical Requirements

S C ELECTRIC EUROPE LTD. Excellence Through Innovation. Harnessing the Wind. November 2011 Descriptive Bulletin E

Guideline for Using IEEE 1547 for Solar PV Interconnection Page 1

DER Commissioning Guidelines Community Scale PV Generation Interconnected Using Xcel Energy s Minnesota Section 10 Tariff Version 1.

P.O BOX 429, NUKU ALOFA, Tel: (676) Fax: (676)

APPENDIX E: Project Need and Description

APPLICATION ELECTRICITY SERVICES. APPLICATION FOR THE CONNECTION OF SMALL SCALE EMBEDDED GENERATION Page 1

FINAL FACILITY STUDY. 230/69/13.8 kv Transformer Addition(s) at Badwater Substation 2009 T1. September 10, 2010

Grid Integration Costs: Impact of The IRP Capacity Mix on System Operations

NORTH CAROLINA INTERCONNECTION REQUEST APPLICATION FORM. Utility: Duke Energy Progress

CONNECTION ASSESSMENT & APPROVAL PROCESS. Cardinal Substation Modification of 115kV Substation

Southern Company Interconnection Process. Dexter Lewis Research Engineer Research and Technology Management

MONTHLY PERFORMANCE DASHBOARD

ELECTRICAL UTILITY COST REDUCTION THROUGH PREDICTIVE CONTROL December 2008 BACKGROUND

The relative site locations are detailed below with the main headquarters circled in blue and the new Fiji Airways Aviation Academy in green.

Procurement Plan. Eskom Holdings SOC Limited. Eskom Investment Support Project

Summary of General Technical Requirements for the Interconnection of Distributed Generation (DG) to PG&E s Distribution System

Elbert County 500 MW Generation Addition Interconnection Feasibility Study Report OASIS POSTING # GI

University of Michigan Eco-Driving Index (EDI) Latest data: October 2017

Connecting your business diesel generation

Inverter-based DER Ride Through and IEEE Standard 1547

Smarter Network Storage UK first multi-purpose application of grid scale storage. Dr. Panos Papadopoulos, PhD, CEng

Distributed Energy Resources

Technical Requirements for Renewable Energy Power System

100 MW Wind Generation Project

Maryland Level 2, Level 3 & Level 4 Interconnection Request Application Form (Greater than 10 kw to 10 MW or less)

SYSTEM INTEGRATION. Railway and urban transport electrification Energy-efficient and reliable solutions

Graph #1. Micro-Generation Generating Units in Alberta 20

Operational Opportunities to Minimize Renewables Curtailments

MENARD ELECTRIC COOPERATIVE POLICY MANUAL. SECTION IV Operating Rules for Cooperative Members

GRID CONNECTION ISSUES FOR DISTRIBUTED GENERATION REVIEW & STANDARDS

Targeted Application of STATCOM Technology in the Distribution Zone

CIS-IEEE 2017 Conference Renewable Energy Session Renewable Energy s Impact of Power Systems

Maryland Level 2, Level 3 & Level 4 Interconnection Request Application Form (Greater than 10 kw to 10 MW or less)

4,1 '~ ~ ~ 1I1f lc/)~ul I Central Electricity Authority

Ameren Missouri. AMENDED Renewable Energy Standard Compliance Report Prepared in Compliance with 4 CSR

15 Nelson-Marlborough Regional Plan

PROCUREMENT PLAN RENEWABLE ENERGY INTEGRATION PROJECT (REIP)

Large Embedded Generation User Guide A

Benefits of a Cooling Tower VFD Retrofit

KERALA STATE ELECTRICITY REGULATORY COMMISSION. NOTIFICATION Dated, Thiruvananthapuram 6 th August,2007

By: Ibrahim Anwar Ibrahim Ihsan Abd Alfattah Omareya. The supervisor: Dr. Maher Khammash

Feasibility Study Report

NSTAR ELECTRIC COMPANY M.D.P.U. No. 28 EASTERN MASSACHUSETTS CAMBRIDGE SERVICE AREA GENERAL SERVICE

PLANNING, ELIGIBILITY FOR CONNECTION AND CONNECTION PROCEDURE IN EMBEDDED GENERATION

Standard Battery Energy Storage System (BESS) Connection Arrangements

Energy storage - two Canadian Case Studies ESA Annual Conference, Washington, June 4th. Alex Bettencourt Managing Director

Interconnection Feasibility Study Report GIP-222-FEAS-R3

What is the Future of Competitive Markets? Some Fundamental Preliminaries and View from Events in the PJM Market

SUMMARY OF TOTAL CURRENT PRICES - ELECTRIC

Transcription:

to: details Version: 2007 Technical Rules 1 16-Jan-08 2 16-Jan-08 3 29-Jan-08 Neerabup (two generating units - Units G11 and G12) Neerabup (two generating units - Units G11 and G12) Bluewaters Power Station Unit 2 3.3.3.1(a) 3.3.3.3(b) 3.3.3.5 4 4-Sep-09 Collgar Wind Farm 3.3.3.10(c)(1) 5 7-Oct-09 Collgar Wind Farm 2.2.10 Modified reactive power capability: 0.8 Lagging 101.3 MVAr 0.9 Leading 68.5 MVAr Financial contribution for the shortfall in reactive power capability, pursuant to clause 3.3.3.1(d). Modified off-nominal frequency capability: 47.0 47.5 Hz 20 seconds 47.5 51.5 Hz continuous 51.5 52.0 Hz 20 seconds 52.0 52.5 Hz 0 seconds Constrained operation for SWIS load below 1960MW. Modified ramping rates: The requirement to respond at a rate of 5% of nameplate rating per minute is modified to require the power station to respond by increasing output by 10 MW in the first 10 seconds and then after one minute increasing output at a rate of 3% of nameplate rating per minute. Identical to for Unit 1, with System Management s acceptance. De-energisation of Generator Circuits: Connection via two circuits and no circuit breakers in the generator s switchyard. Deemed to be technically and commercially optimal arrangement. Financial contribution made for the switchyard. Modified overvoltage performance requirements: The overvoltage capability curve proposed by the generator applies in lieu of that of clause 2.2.10, Figure 2.1. The connection point site-specific overvoltage performance requirements (as assessed by Western Power) are met by the generators over voltage capability.

to: details 6 10-Jun-10 7 25-Oct-10 Tesla, Harris Road, Leeming Road, Deepdale Road and Kemerton 10.0 MW Power Stations Grasmere Wind Farm 3.3.1(c) 3.2.2 8 23-Mar-11 Synergy 3.7.8.3(b) 9 24-Aug-11 Bluewaters Power Station Unit 2 Version: 2011 Technical Rules 10 23-Feb-12 Extension Hill Pty Ltd (EHPL) transmission load 3.3.3.1 3.2.2 Requirements for generator units (general): Assessment permitted under clause 3.6 for small generators. Initial misinterpretation of the applicable requirements (by both Western Power and Tesla) and advanced stage of these projects at the time the correct interpretation became apparent. Main Switch: Utilisation of Western Power feeder circuit breaker to de-energise wind farm in lieu of wind farm main switch. Integration into Albany zone substation and existing voltage control scheme via the 3rd identical 22kV (wind farm) feeder is deemed the best solution. Additional cost of technical compliance would increase operational complexity and not provide any tangible benefit. Financial contribution made for the switchyard. Inspection and testing: Inspection and testing requirements waived, pursuant to the Office of Energy s Final Outcomes Report and subsequent recommendation to change the Technical Rules accordingly. Modified reactive power capability: For steady state voltages from 90.5% to 90% of the rated voltage at the connection point, the required reactive power absorption is at least the amount equal to the product of the rated active power output of the generation unit at nominal voltage and 0.441. The connection point site-specific reactive power absorption capability is acceptable to Western Power and System Management. Main Switch: Modified switchyard arrangement for the initial EHPL single circuit connection: Utilisation of Western Power circuit breaker to de-energise transmission load. There is no benefit in these particular circumstances in requiring EHPL to install its own 330kV main switch at Three Springs terminal substation.

to: details 11 18-Apr-12 12 25-Sep-12 13 6-v-12 14 17-Jan-13 15 17-Jan-13 Karara Power Pty Ltd (KPPL) transmission load PTA, City railway substation West Hills and Anderson wind farms Verve Energy, Muja D Verve Energy Kwinana HEGT 200 MW Power Station 3.2.2 3.2.1(d)(2) 2.9.2(b) 2.2.8(a); 2.2.8(b) 2.2.8(a); 2.2.8(b) Main Switch: Modified switchyard arrangement for the initial KPPL connection: Utilisation of Western Power circuit breakers to de-energise transmission load. There is no benefit in these particular circumstances in requiring KPPL to install its own 132kV main switch at Eneabba substation and 330kV main switch at Three Springs terminal substation. Negative phase sequence: Two-phase connection accepted. The is pursuant to clause 1.9.4(a), as the project was well advanced before 23 Dec 2011, being the commencement date for the revised Technical Rules (current) in which clause 3.2.1(d)(2) was materially changed. Duplication of protection: Two external generator protection relays supplied from a single voltage transformer (VT). In case of loss of the VT input to the protection relay, the VT supervision function of the relay will send the trip signal to disconnect the wind farm, which is considered as an acceptable functional alternative to duplication of the VTs. Modified damping of oscillations: The respective damping ratios must be at least 0.07 and 0.27. The performance (after automatic voltage regulator replacement) is at least equivalent to the previous performance. Modified damping of oscillations: Power system studies and commissioning test results that showed that connection of the Kwinana HEGT power station with modified damping ratios will cause no adverse impact on the South West Interconnected System

to: details 16 23-Jan-13 17 14-Feb-13 18 21-Jun-13 19 17-Sep-13 20 23-Dec-13 Inverter connected generation units 30 to 150kVA Grasmere Wind Farm Collgar Wind Farm, Stage 1 Bluewaters Power Station Unit 1 & Unit 2 Kwinana Donaldson Road Power Station Unit 1 & Unit 2 2.9.2(b) 3.3.4.5(g), Table 3.2 3.3.3.3(h)(2) 3.3.4.4(b) 2.2.8(a) & (b) 08-Dec-15 21 20-Jan-14 NewGen Kwinana 3.3.4.4 30-Jun-14 Duplication of protection: One (only) IEC60255 compliant external generator protection relay required in conjunction with protections integral to AS4777-2005 compliant inverters in the capacity range of 30 to 150 kva. Number of s (to 30-Sept-2016): 99 Modified rise time: The maximum permitted rise time is 3.0 seconds. There is no benefit in these particular circumstances in requiring modification of the integrated Albany wind farm control scheme (of which Grasmere is Stage 2) to achieve compliance. Modified active power recovery time: The maximum permitted recovery time is 1,000 milliseconds. adverse effect on the network performance or other customers for the currently installed wind farm capacity outweighs the significant cost of compliance. Temporary to complete repairs. Reasonable repair time frame agreed to suit both parties in order to bring the Units back into compliance. Modified damping requirements: The was based on the analysis conducted by Western Power, which determined that the does not create material impact on Western Power s network performance and other customers for the currently installed power station capacity. in order to allow sufficient time for the investigation and implementation of a solution in line with the capability of the units and the governor compliance issues.

to: details 22 20-Jan-14 Alinta Cogeneration Wagerup Power Station - Unit 1 & Unit 2 3.3.4.4 31-Dec-14 in order to allow sufficient time for the investigation and implementation of a solution in line with the capability of the units and the governor compliance issues. 23 20-Jan-14 Alinta Cogeneration Pinjarra Power Station - Unit 1 & Unit 2 3.3.4.4 31-Mar-15 in order to allow sufficient time for the investigation and implementation of a solution in line with the capability of the units and the governor compliance issues. 24 7-Mar-14 Ferngrove Vineyards Ltd 200kVA Solar PV Power Station 3.6.10.1(g) & 2.9.2(b) 31-Dec-14 Protection (general) and duplication of protection: Temporary to allow for the installation of voltage transformer and NVD protection. 25 29-Apr-14 Mitchell Foods Pty Ltd 150kVA Solar PV Power Station 3.2.1(c)(3) 31-Jul-14 Harmonics: to allow sufficient time for the procurement of an isolation transformer and installation and completion of the final facility to achieve compliance. 26 2-Oct-14 Dradgin Pty Ltd, 502 Hay street, Subiaco 3.6.10.1(a) Protection (Location): All protection functions specified in 3.6.10 must be provided with protection equipment located as close as practicable to the connection point. 27 2-Jan-15 Department of Defence, Carnegie Wave Energy Unit 3.6.10 02-Jan-16 Protection: allows variation of protection requirements to allow sufficient time for Department of Defence to upgrade protection equipment and switchboards at the connection point. 28 1-Dec-14 Low voltage invertor connected generator systems rated between 30kVA and 150 kva 3.6.10.1(g) 31-Aug-16 Network Earth Fault (E/F) Protection: E/F and Neutral Voltage Displacement (NVD) protection requirements will be assessed on a case by case basis by Western Power. Number of s (to 30-Sept-2016): 128 29 28-Apr-15 Brockway DiCOM Facility Pty Ltd Shenton Park PPG 3.6.10.1(a) Protection (Location): All protection functions specified in 3.6.10 must be provided with protection equipment located as close as practicable to the connection point.

to: details 30 15-May-15 Low voltage connection points 3.2.1(c)(3) 31-Dec-16 Modified DC Injection Limits: Users must complete the Technical Rules Direct Current (DC) Injection Transition form available on the Western Power web site and meet the requirements therein. Number of s (to 30-Sept-2016): 75 31 17-Jun-16 NewGen Power Kwinana 3.3.4.5, Table 3.1 30-Jun-17 Settling time: Amended requirements reflect realistic performance capability of plant. 32 17-Jun-16 NewGen Power Kwinana 3.3.3.3(d) 30-Jun-18 Rate of change of frequency (RoCoF): Amended requirements reflect realistic performance capability of plant. 33 06-Jul-16 Bluewaters Power 3.3.4.4 30-Jun-17 Amended requirements reflect present tested performance capability of plant. 34 12-Sep-16 NewGen ERM Neerabup 3.3.4.4(f)(1) 01-Jul-17 Frequency control: Investigation ongoing to establish maximum rate of response capability of plant.