Est.1968 FlexiPower Mini UPS FPX Mini 10 200kVA
The FlexiPower Mini ST is designed to provide medium critical power users the highest flexibility and growth opportunity platform available today utilising hot swappable user technology. Designed and Published by Thycon.
DESIGNED TO PROVIDE LARGE SYSTEM BENEFITS FOR MEDIUM POWER APPLICATIONS Designed for medium power applications, the FlexiPower Mini ST delivers true modular power protection from 10 to 200 kw (one to ten modules) in a single industry-standard frame. Its flexible design provides a pay as you grow model, ideal in situations where requirements change quickly and unpredictably. The FlexiPower Mini ST enables cost reduction through best-inclass efficiency performance, fast and efficient implementation and extremely low overall operating costs. The modular FlexiPower Mini ST is based on Thycon s proven Modular Parallel Architecture (MPA). MPA means that each UPS module contains all the hardware and software required for full system operation. They share no common components, and as a result system uptime is maximized. Space costs money and with a footprint of only 0,42 m2 FlexiPower Mini ST (10 200 kw) takes up less floor space than alternative UPS solutions. The UPS provides all the benefits of a modular UPS solution with a maximum power density of 472 kw / m2. FlexiPower Mini highlights Capacities from 10 to 200 kw in 10 or 20 kw modular steps N + 1 redundancy (up to 10 kw N + 1) Up to 96 % efficiency across a wide load range Near-unity input power factor at partial and full loads (PF of > 0.99 at 100 % load) Low input harmonic distortion (THDi of < 3 %) 472 kw / m2 power density Six nines availability With MPA technology each UPS module has its own independent logic control control panel rectifier inverter battery charger static bypass Designed and Published by Thycon. > FlexiPower Mini ST 3
MAINS rectifier inverter static bypass logic control control panel rectifier inverter static bypass logic control control panel MPA ALWAYS PROTECTING YOUR CRITICAL APPLICATIONS rectifier inverter static bypass logic control control panel CHARGE The three major concerns of IT facility managers when assessing the life-cycle cost of their power protection infrastructure are availability, flexibility and total cost of ownership (TCO). The FlexiPower Mini ST is based on Thycon s proven Modular Parallel Architecture (MPA) that has been developed specifically to respond to these concerns. MPA maximum availability Parallel architecture limited only to modular design does not guarantee the highest power protection for critical applications. The success of a parallel modular system depends largely on the design of the parallel architecture and on the level of intelligence of the individual modules. Modular systems based on MPA are free of single points of failure and maximize the system s mean time between failure (MTBF). Quick and simple repair by safe-swapping modules while the UPS is online minimize the system s mean time to repair (MTTR). Thycon s modular FlexiPower Mini ST is built of self-contained modules that include the entire UPS hardware and software; hence, it eliminates all the common parts which are potential single points of failure. An MPA module includes distributed CPUs, distributed control panels, distributed power units and distributed static bypass switches. Even the batteries are separately configured for each module, which makes the parallel system fully and truly redundant. MPA high level of flexibility UPS systems based on MPA allow for incremental expansions whilst ensuring redundancy at all times. It is possible to start with just a few modules and add to them as required in an easy and safe way. True safe-swap and safe-scale modularity enables the safe replacement of UPS modules and their integration into the UPS system without the need to transfer the critical load onto raw mains or to remove power from the critical load. MPA lowest total cost of ownership Saving costs and optimizing capital deployment are top priorities, and IT facility managers must make effective investments to increase the efficiency of their IT systems. An infrastructure that uses cost-effective and flexible modular power protection solutions with significantly lower operating costs will create competitive advantages in the medium term. The FlexiPower Mini ST boasts the lowest cost of ownership of any UPS system by offering energy efficiency, scalable flexibility and highest availability due to true redundancy and easy serviceability. 4
General Data ST 40 ST 60 ST 80 ST 120 ST 200 Number of UPS modules 2 3 4 6 10 Maximum number 80 240 of inbuilt batteries Maximum output power 40 kw 60 kw 80 kw 120 kw 200 kw Output power factor 1.0 Topology True online double conversion Parallel configuration Up to ten modules UPS type MPA (Modular Parallel Architecture) Cable entry Front access Input Nominal input voltage 3 380 / 220 V + N, 3 400 / 230 V + N, 3 415 / 240 V + N Voltage tolerance For loads <100 % ( 20 %, +15 %), < 80 % ( 26 %, +15 %), < 60 % ( 35 %, +15 %) (Ref. to 3 400 / 230 V) Input distortion THDi 3 % at 100 % Frequency 35 70 Hz Power factor 0.99 at 100 % load Output Rated output voltage 3 380 / 220 V + N, 3 400 / 230 V + N, 3 415 / 240 V + N Voltage distortion < 1.5 % (Ref. to 3 400 / 230 V) Frequency 50 or 60 Hz Overload capability 10 min.: up to 125 % or 1 min.: up to 150 % Unbalanced load 100 % possible Crest factor 3 : 1 Efficiency Overall efficiency Up to 96 % In eco-mode configuration 98 % Environment Storage temperature 25 70 C Operating temperature 0 40 C Altitude configuration 1000 m without derating Communications LCD display Yes (per module) LEDs LED for notification and alarm Communication ports USB, RS-232, SNMP slot, potential-free contacts Standards Safety IEC / EN 62040-1 Electromagnetic IEC / EN 62040-2 compatibility (EMC) Performance IEC / EN 62040-3 Product certification CE Manufacturing ISO 9001:2008, ISO 14001:2004 Weight, Dimensions Weight (with modules / without batteries) Up to 135 kg Up to 238 kg Up to 168 kg Up to 262 kg Up to 389 kg Dimensions W H D (mm) 550 1135 770 550 1975 770 550 1135 770 550 1975 770 550 1975 770 Specifications are subject to change without notice. Designed and Published by Thycon. > FlexiPower Mini ST 5
Product types ST 40 ST 60 ST 80 ST 120 ST 200 Maximum output power 40 kw 60 kw 80 kw 120 kw 200 kw No. of internal batteries (7 / 9 Ah) Up to 80 Up to 240 Dimensions W H D (mm) 550 1135 770 550 1975 770 550 1135 770 550 1975 770 550 1975 770 Weight frame (without modules / without batteries) 92 kg 173 kg 82 kg 133 kg 174 kg High power low weight! 20 kw = 21.5 kg MODULES M 10 or M 20 FLEXIPOWER MINI ST SYSTEM ARCHITECTURE The FlexiPower Mini ST can be deployed in a variety of system architectures to support the specific requirements of your IT infrastructure. The ST 40 and ST 60 cabinet types are suitable for applications with low runtimes, limited space and no extension requirements. For larger autonomies and incremental future growth, the ST 80, ST 120 and ST 200 are the best choices Maximum output power Weight Dimensions W H D (mm) FlexiPower Mini ST safe-swap modularity The ability to safe-swap modules significantly reduces the system s mean time to repair (MTTR) and simplifies system upgrades. Thanks to the unique, compact design and low weight (10 kw = 10 or 20 kw 18.6 or 21.5 kg 488 132 540 (3 HU) 18.6 kg, 20 kw = 21.5 kg) of the FlexiPower Mini modules, inserting additional modules or replacing existing ones during operation is easy and can be performed by a single technician. 6
Notes 7
THYCON INDUSTRIAL PTY LTD 20 Audrey Ave Coburg 3058 VIC Australia PH 61 3 9319 9000 FAX 61 3 9319 9001 ABN 17 068 011 049 www.thycon.com.au info@thycon.com.au 24 HR Service Australia 1800 670 700
Est.1968 FlexiPower Mini RI FPX Mini 10 80 kw
Modular three-phase UPS system The modular UPS for customized solutions. Designed and Published by Thycon.
FLEXIPOWER MINI RI ALWAYS PROTECTING YOUR CRITICAL LOAD The rack-independent FlexiPower Mini RI (rack-independent) is one of the most customizable UPS systems on the market and provides the best technical and commercial solutions to meet individual power protection needs. The three-phase and modular UPS system can be integrated into any 19 cabinet, regardless of the rack s manufacturer. The multi-purpose FlexiPower Mini RI simplifies the engineering and deployment of customized power protection solutions. The UPS system allows system integrators to add their own knowhow and to implement individual solutions according to their design requirements. FlexiPower Mini RI can be integrated into any weatherresistant enclosure to withstand the demands of the harsh outdoor environments. The rackindependence allows FlexiPower Mini RI to be used all over the world on oil rigs, ferries and commercial shipping vessels, just to name a few. In the rack, the warm air is discharged to the back. This allows the warm air to exit the cabinet through the top air path without heating up the whole enclosure. In any case, it is important that system integrators take the air conditioning into account. FlexiPower Mini RI 20 FlexiPower Mini RI always protecting your critical load The three major concerns of IT managers when assessing the life-cycle cost of their power protection infrastructure are availability, flexibility and total cost of ownership (TCO). FlexiPower Mini RI simultaneously addresses all three concerns. FlexiPower Mini RI is based on Thycon s Modular Parallel Architecture (MPA) that has been developed specifically to respond to stringent life-cycle cost requirements. Maximum availability Modular systems based on MPA are free of single points of failure. The modular FlexiPower Mini RI is built of self-contained modules that include the entire UPS FlexiPower Mini RI 22 hardware and software; hence, it eliminates all the common parts that are potential single points of failure. High level of flexibility UPS systems based on MPA allow for incremental expansions whilst ensuring redundancy at all times. It is possible to start with just a few modules and add to them as required in an easy and safe way. Low total cost of ownership FlexiPower Mini RI boasts the lowest cost of ownership of any UPS system by offering energy efficiency, scalable flexibility and highest availability due to true redundancy and easy serviceability. FlexiPower Mini RI 24 Designed and Published by Thycon. > FlexiPower Mini RI 3
AC AC efficiency 100 95 90 85 80 75 Linear Load (cos phi = 1) 25% 50% 75% 100% charge The flat efficiency curve enables significant energy savings in every working condition. Input power factor versus load 1.0 0.8 25% 50% 75% 100% charge The input power factor of FlexiPower Mini RI is near unity at partial and full load. Input current total harmonic distortion (THDi) 6 5 4 3 2 1 0 25% 50% 75% 100% charge Class-leading THDi of < 3 % virtually eliminates harmonic distortion of the mains supply. 4
General Data RI 10 RI 11 RI 12 RI 20 RI 22 RI 24 RI 40 Number of UPS modules 1 1 1 2 2 2 4 Maximum number of inbuilt batteries 40 80 80 160 Maximum output power 20 kw 20 kw 20 kw 40 kw 40 kw 40 kw 80 kw Output power factor 1.0 Topology UPS type Cable entry Input Nominal input voltage Voltage tolerance (Ref. to 3 400 / 230 V) True online double conversion Modular (Modular Parallel Architecture) Rear access Input distortion THDi 3 % at 100 % Frequency Power factor Output Rated output voltage Voltage distortion (Ref. to 3 400 / 230 V) Frequency 3 380 / 220 V + N, 3 400 / 230 V + N, 3 415 / 240 V + N For loads <100 % ( 20 %, +15 %), < 80 % ( 26 %, +15 %), < 60 % ( 35 %, +15 %) 35 70 Hz 0.99 at 100 % load 3 380 / 220 V + N, 3 400 / 230 V + N, 3 415 / 240 V + N < 1.5 % 50 or 60 Hz Overload capability 10 min.: 125 % or 1 min.: 150 % Unbalanced load Crest factor 3 : 1 Efficiency 100 % possible Overall efficiency Up to 96 % In eco-mode configuration 98 % Environment Storage temperature 25 70 C Operating temperature 0 40 C Altitude configuration Communications LCD display LEDs Communication ports Standards 1000 m without derating Yes (per module) LED for notification and alarm Safety IEC / EN 62040-1 Electromagnetic compatibility (EMC) USB, RS-232, SNMP slot, potential-free contacts IEC / EN 62040-2 Performance IEC / EN 62040-3 Product certification Manufacturing ISO 9001:2008, ISO 14001:2004 Weight, Dimensions CE Weight (with modules / without batteries) Up to 39 kg Up to 62 kg Up to 78 kg Up to 68 kg Up to 109 kg Up to 136 kg Up to 136 kg Dimensions W H D (mm) 488 310 565 (7 HU) Specifications are subject to change without notice. 488 487 735 (11 HU) 488 665 735 (15 HU) 488 440 565 (10 HU) 488 798 735 (18 HU) 488 1153 735 (26 HU) 488 798 735 (18 HU) Designed and Published by Thycon. > FlexiPower Mini RI 5
Product types RI 11 RI 12 RI 22 RI 24 RI 10 RI 20 RI 40 Maximum output power 20 kw 20 kw 40 kw 40 kw 20 kw 40 kw 80 kw No. of internal batteries 40 80 80 160 Dimensions W H D (mm) 488 487 488 665 488 798 488 1153 488 310 488 440 488 798 735 (11 HU) 735 (15 HU) 735 (18 HU) 735 (26 HU) 565 (7 HU) 565 (10 HU) 735 (18 HU) Weight sub-rack (without modules / without batteries) 40 kg 56 kg 66 kg 93 kg 20 kg 25 kg 50 kg MODULES M 10 or M 20 Maximum output power Weight Dimensions W H D (mm) 10 or 20 kw 18.6 or 21.5 kg 488 132 540 (3 HU) FLEXIPOWER MINI RI SYSTEM ARCHITECTURE The core elements consist of best-in-class hardware and software that respond to diverse customer applications and changing business needs. All FlexiPower Mini RI components can be mounted directly in any 482.6 mm (19 ) cabinet of 800 or 600 mm (RI 10, RI 20) depth. Depending on the requirements, mixed equipment population is also possible. FlexiPower Mini RI is available in seven configurations with or without inbuilt battery blocks. Highlights for system integrators Rack-independence Efficient manufacture of individual solutions with standard products High local added value FlexiPower Mini RI safe-swap modularity The ability to safe-swap modules significantly reduces the system s mean time to repair (MTTR) and simplifies system upgrades. Thanks to the unique, compact design and low weight (10 kw = 18.6 kg, 20 kw = 21.5 kg) of the FlexiPower Mini RI modules, inserting additional modules or replacing existing ones during operation is easy and can be performed by a single technician. 6
Notes 7
THYCON INDUSTRIAL PTY LTD 20 Audrey Ave Coburg 3058 VIC Australia PH 61 3 9319 9000 FAX 61 3 9319 9001 ABN 17 068 011 049 www.thycon.com.au info@thycon.com.au 24 HR Service Australia 1800 670 700