Installation and Wiring Instructions for the TL- Prefix SARGuide Illuminated Touchpad for 80 Series Exit Devices to ElectroLynx Connector System

Similar documents
56- Electric Latch Retraction Exit Devices Installation and Wiring Instructions

Motorized Electric Latch Retraction

8800 Rim Exit Device 80 Series

Access 800. Installation Instructions for CL33800 TCAC2 Series Cylindrical Lockset

4500 Series Electric Exit Devices Request to Exit (RX) Installation Instruction Grade 1 I-ED00368

8500 Narrow Design Rim Exit Device 80 Series

v.g1.5 Profile & LK Mortise Lock Installation Instructions A7855D 04/18

Installation Instructions for CL33800 TCAC2 Series Cylindrical Lockset

8800 Rim Exit Device 80 Series

ELR Series Multi-Point Lock Installation Instructions

ASSA ABLOY Series Power Operator Installation and Instruction ASSA Manual ABLOY ASSA ABLOY

Requirements LEO Power Operator Installation Instructions Patents: 5,881,497; 7,316,096; 7,484,333 CAUTION CAUTION WARNING

8800 Rim Exit Device 80 Series

Requirements LEO Power Operator Installation Instructions Patents: 5,881,497; 7,316,096; 7,484,333 CAUTION CAUTION WARNING

ASSA ABLOY Series Power Operator Installation and Instruction ASSA Manual ABLOY ASSA ABLOY

PRICE LIST. Table of Contents

9700/F9700 SERIES RIM EXIT DEVICE

How ElectroLynx Helps

268, 269 & 278. Concealed Door Closers

ASSA ABLOY. Installation Instructions. MP9800 Series Multi-Point Lock with MELR Option (Electric Latch Retraction)

ASSA ABLOY. Access 600 Integrated Wiegand. with MELR Option (Electric Latch Retraction) Access 600 Integrated Wiegand ASSA ABLOY.

Cylindrical Lockset Installation Instructions CL33600 TCRNE1 Series M812 - iclass Reader Option

ACSI MODEL 1406BB-04-AO POWER SUPPLY INSTALLATION INSTRUCTIONS

2904 Power Supply Installation Instructions I-EA00041

Installation Instructions For Profile Series v.g1.5 Cylindrical Lock

INSTALLATION INSTRUCTIONS DEGR7700 DELAYED EGRESS ALL IN ONE DEVICE

ELECTRICAL SYSTEM RP-7

4700LN Series ANSI/BHMA Grade 1 Certified Cylindrical Lever Locks. An ASSA ABLOY Group brand

8888/8810 Multi-Function Rim Exit Device & Trim 80 Series

Transfer Device Solutions DATED MATERIAL

Transfer Device Solutions

Senior Swing Control Box. Table of Contents

Entry. Entry. Entry. Entry

Installation & Programming Guide

INSTALLATION MANUAL. Model: PLUS For Technical Assistance, please call (800) , or visit

CTC 400 Cab Trailer Communication Power Line Carrier Technology Communications for Trucks and Trailers

5600 Series Power Operator Installation and Instruction Manual

CL33900 Electrified Lockset

1500 Series and 1600 Series Electric Strikes Installation Instructions

Flight Systems. Replacement for KASSEC DESCRIPTION

1500 Series and 1600 Series Electric Strikes Installation Instructions

ARCHITECTURAL CONTROL SYSTEMS, INCORPORATED ST. LOUIS, MISSOURI

WARNING: Make sure that (120V, 60Hz) input power is turned off at facility s main circuit breaker before proceeding with installation.

5700 Series Power Operator Hinge (Pull) Side Mount Installation and Instruction ASSA Manual ABLOY

Model PRO 9246CH Installation Manual

Shaved-B. Installation Manual & Operation Instructions


Electromagnetic Door Holder/Releases

MODELS TRUE WOOD DOOR OPERATIONAL HARDWARE EXIT DEVICE MODELS LEVER X LEVER MODELS DOORS WITH FLUSHBOLTS:

Dated Material for. Training Purposes Only TOC-1 TABLE OF CONTENTS. General Information. High Security Mortise Lock Cylinders & Keying

3200NT Timer Service Manual

ADAMS RITE. ADAMS RITE MANUFACTURING COMPANY Sliding Hardware/Exit Devices Series Turns

Proper installation of this product requires the installer to have a good understanding of automotive electronics, systems and procedures.

Electrical Options Booklet. Table of Contents

MAXIMA MOTORISED LOCKS

GRADE 1 ELECTRIFIED CYLINDRICAL & UNIT LOCKS

LCN AUTOMATIC OPERATORS

BOM505 Black Out Module Ford F-150 Contact InterMotive for additional applications

5700 Series Power Operator Stop (Push) Side Mount Installation and Instruction

6900 Series PowerMatic Low Energy Power Operator

6900 Series PowerMatic. Low Energy Power Operator

7100SZ Series SafeZone Installation and Instruction Manual

5300LN Series. ANSI/BHMA Grade 2 Certified Cylindrical Lever Locks

Mortise Lockset Installation Instructions ML20600 TCRNE1 Series M812 - iclass Reader Option

98/99 Dogging options

C FORD F250 / F L POWERSTROKE DIESEL WITH AUTOMATIC TRANSMISSIONS ONLY

D3375 SERIES INSET EXIT DEVICE HARDWARE METAL DOOR OPERATIONAL HARDWARE SPECIFICATIONS FEATURES. D3375 Series Certifications

Switches- and Indicators

TS93 EMF T/PT/TDE. Surface applied door closer

An ISO 9001:2008 Registered Company

* * M400 Series. Features. Models. Trims. UL Requirements. Single Electromagnetic Locks: M420, M450, M490. Installation Instructions

IMI vibration switch USER MANUAL INSTALLATION - OPERATION - MAINTENANCE

Model APS-101N Installation Manual

ASSA ABLOY MPI (Infinite Hold Open Range) Support Unit Models. Multi-Point Electromechanical Overhead Concealed Closer Holder Releasing Device

Installation Instructions

CL3300 Series. Cylindrical Lockset Parts Manual

BOILER BLOWDOWN CONDUCTIVITY CONTROLLER (CONTINUOUS METHOD)

7100SZ Series SafeZone. Multi-Point Closer/Holder with Motion Sensor

5000 SERIES POWER SUPPLY/CHARGERS INSTALLATION GUIDE

7100SZ Series SafeZone. Multi-Point Closer/Holder with Motion Sensor

HM SERIES. (Outdated connector) Features P-01

3400 Series

INSTALLATION MANUAL. Remote Mobile Security System. Model: PL30

C-PIM701 (Police Interface Module) 2018 Dodge Charger Pursuit

Spectra Class - Specification Grade Exit Devices for superior Architectural Style & Performance

HANDLING MECHANICAL INSTALLATION

BOM507-BC Black Out Module 2017 Ford F250-F550 Contact InterMotive for additional applications

Power Supplies DORMA PS

Table of Contents Specialty Hardware

AL600ULX Series. Power Supply/Charger Installation Guide

Addendum. SL3000ULE series. to the SL3000UL series owners manual. manually push vehicular gate open for emergencies

Table of Contents Auxiliary Locks

The Power Systems Industry Experts. Installation Instructions. PT100 Stationary Generator Monitoring System

WARNING TABLE 3-1: DAILY SAFETY CHECK

USERS GUIDE LO-21U LOCKOUT RELAY

An ISO 9001:2008 Registered Company

Control Replacement # Page 1 REPLACEMENT OF OBSOLETE SEMI- AUTO CONTROLS WITH KIT #

Visit our web site at AMR LS-3000, LS-3010 & LS-3020 BELT SLIP/SEQUENCE CONTROL INSTALLATION AND SETUP INSTRUCTIONS

FIRE DOOR OPERATOR WARNING INSTALLATION LOGIC BOARD REPLACEMENT KIT K , K A-400 & K B-400 APPLICATION REMOVE AC AND DC POWER

7100SZ SERIES. Multi-Point Closer/Holder with Motion Sensor

Transcription:

Installation and Wiring Instructions for the TL- Prefix SARGuide Illuminated Touchpad for 80 Series Exit Devices to ElectroLynx Connector System U.S. Patent No. 7,04,050 For assistance, contact SARGENT at 800-80-WIRE (9473) or www.sargentlock.com A. Function The SARGuide exit device contains an illuminated touchpad to enhance the visibility of exit locations in dark or smoke-filled passages and is intended as a supplement to existing codes for egress lighting. B. Important. Caution: Disconnect all input power before beginning installation to prevent electrical shock and equipment damage.. Installer must be a trained, experienced service person. 3. All wiring must comply with applicable local electrical codes, ordinances and regulations. 4 3, Violet (-4), Grey (+4) SARGuide TL- 80 Series Rail C. ElectroLynx Connector System The system is designed to be installation friendly with connectors from the electric hinge through the door to the rail. The only wiring required is to the loose wires on the pigtail harness assembly on the frame side of the electric hinge. IMPORTANT: The plug and receptacle connectors are designed to mate and lock together as shown in the figure. Plug the connectors into each other with the locking mechanism aligned as indicated. Do NOT force connectors on any other way. D. Installation Notes. With new applications, a raceway harness with 8 & 4-pin connectors will be pre-installed inside door by ASSA ABLOY door manufacturer when specified during ordering process. Raceway harness kits are also available for retrofit applications. For retrofit applications, refer to retrofit instructions.. If door does not have a raceway harness with connectors, either consult factory for raceway retrofit kit, or cut the connectors off product and hard wire as required.. Wiring to pigtail harness is per facility wiring requirement. The rail, raceway, electric hinge and pigtail connector terminations and wire colors all match. Copyright 009, SARGENT Manufacturing. All rights reserved. A77C - 5--9

E. TL- SARGuide Exit Device Installation Mounting bracket Screw location " dia hole in door 4 Electric Hinge with 3 TL- SARGuide 80 Series Rail The 4-pin connectors are not used here. 4 to 8-pin patch cable (see note ). Mount exit device per instruction sheet provided.. TL- (SARGuide) only without other rail wiring requirements - Install 4 to 8-pin patch cable between the rail and raceway connectors. TL- (SARGuide) with other rail wiring requirements - Do NOT install 4 to 8-pin patch cable. Refer to the wiring diagrams on the following pages. If additional electrical functions exist, plug rail 8 & 4-pin connectors into raceway connectors. Feed harnesses through " hole in door. Install rail mounting bracket with two screws supplied. Install rail insert and end cap. To insure trouble free operation, check that the push rail can be fully depressed. On vertical rod exit devices, adjust rods and check that the latch bolts do not go into hold back position until the push rail is fully depressed. 3. Plug raceway connector(s) into electric hinge connector(s), then feed through door prep. Mount electric hinge to door. 4. Go to (A) if wiring now. Go to (B) if wiring is to be done later. A. Refer to wiring examples. Wire loose frame side wires to loose wires on pigtail harness as required, using connectors allowed by local code. Plug pigtail harness connector(s) into electric hinge connector(s). Feed harnesses through frame prep and mount electric hinge. Apply power and test exit device B. Plug pigtail harness connector(s) into electric hinge connector(s). Feed harnesses through frame prep and mount electric hinge. Copyright 009, SARGENT Manufacturing. All rights reserved. A77C - 5--9

F. TL- SARGuide Wiring Examples Sample Wiring # TL- Prefix SARGuide and 353 and Back-up 353 4VDC, Amp w/ Backup TB TB 3 4 5 6 7 8 9 0 VAC 0VAC 60HZ 4VDC, Black (-4), Red (+4) System Description: SARGuide is always powered. During a power outage SARGuide remains powered and illuminated by 353 battery back-up power.. TL- SARGuide power requirement: Input Power: 4VDC/VAC Current draw: 30mA Plug pigtail harness connector into 8-pin hinge connector at frame side of door Electric Hinge with s 8 pin connector. TL- Sarguide 80 Series Rail 8 to 8-pin patch cable., raceway and electric hinge terminations and wire colors all match. 3. 4 to 8-pin patch cable converts TL- 4-pin connector pins & to pins &. 4. Wire to pigtail harness assembly as shown then plug pigtail connector into hinge connector. Copyright 009, SARGENT Manufacturing. All rights reserved. A77C - 5--9 3

F. TL- SARGuide Wiring Examples cont d Sample Wiring # TL- (SARGuide) with - 58- (Electric Dogging) combination and 353 with Back-up. 53-, 55- wiring if required. Normally Closed Fire Alarm Connection By Others 353 4VDC, Amp w/ Backup 3 4 5 6 7 8 9 TB TB 80 series rail prefixes 53- latch bolt monitor swicth 55- signal switch 58- electric dogging 55- (NC) Brown, 8 55- (NO) Yellow, 7 55- (C) Blue, 6 53- (NC) Orange, 5 53- (NO) Green, 4 53- (C) White, 3 0 VAC 0VAC 60HZ 4VDC 58- (+4) Red, 58- (-4) Black, # 4 3, Violet (TL -4), Grey (TL +4) # 4-pin connector System Description: SARGuide is always powered. During a power outage SARGuide remains powered and illuminated by 353 battery back-up power. Fire Rated Operation: If using -58- Electric Dogging in conjunction with SARGuide, a normally closed fire alarm contact (by others) must be used and must be wired as shown. Electric hinge with 8 & 4-pin connectors -TL- 58-80 Series Rail with 8 & 4-pin connectors. TL- SARGuide power requirement: Input Power: 4VDC/VAC Current draw: 30mA. Pigtail assemblies, electric hinge, raceway and rail connector terminations and wire colors all match. 3. For 53, 55- and 58- wiring also refer to individual product instructions provided. Wire as required by rail type used. 4 Copyright 009, SARGENT Manufacturing. All rights reserved. A77C - 5--9

F. TL- SARGuide Wiring Examples cont d Sample Wiring #3 TL- (SARGuide) with 57- (Delayed Egress) combination and 353 with Back-up. 353 4VDC, Amp w/ Backup TB TB System Description: SARGuide and the 57- Delayed Egress device are always powered. During a power outage, SARGuide remains powered and illuminated and the 57- Delayed Egress device remains powered by the 353 battery back-up power. 3 4 5 6 7 8 9 Red (+4), 0 VAC 0VAC 60HZ Normally Closed Fire Alarm Contact (If Required) White (FA), 3 Blue (DS), 6 7, Brown, Mag (-) 8, Yellow, Mag (+) To TL- 4 3, Violet (-4), Grey (+4) 4-pin connector Black (-4), Green (EG), 4 Red (+) To 57- Black (-) Plug pigtail harness connectors into electric hinge connectors at frame side of door Electric hinge with 8 & 4-pin connectors 8 & 4-pin connectors EXIT EXIT EXIT EXIT EXIT EXIT TL- 57-80 Series Rail with 8 & 4-pin connectors 584 Electromagnetic Lock. TL- SARGuide power requirement: Input Power: 4VDC/VAC Current draw: 30mA. Rail, raceway, electric hinge and pigtail 8 & 4-pin connector terminations and wire colors all match. 3. If fire alarm is not required, connect the white wire to the black (-4VDC) wire. 4. The fire alarm contact could be wired to drop 4DC power to 57- portion of rail. Refer to 3530 power supply instructions for wiring. 5. Refer to 57- instructions for wiring, specifications, operation, etc. Copyright 009, SARGENT Manufacturing. All rights reserved. A77C - 5--9 5

F. TL- SARGuide Wiring Examples cont d Sample Wiring #4 TL- Prefix (SARGuide) with Solenoid Exit Trim (ET) and 353 and Back-up SARGuide is always powered. During a power outage SARGuide remains illuminated by 353 battery back-up power. The 353 power supply also provides battery back-up power to the solenoid exit trim (ET), which is used to control access. 353 4VDC, Amp w/ Backup TB TB 3 4 5 6 7 8 9 Typical wiring to fail secure ET shown. Refer to 773-6 ET instructions for wiring requirements, specifications, etc. NO 0 VAC C * Switch or relay contacts NC 0VAC 60HZ 4VDC, Black (TL -4), Red (TL +4), Black (773-6 ET), Red (773-6 ET) # # Raceway harness # with The 4-pin connectors are not shown or used here. Electric Hinge # with s 773,774, 775 or 776 Solenoid ET with. Plug into raceway connector., Red (+), Black (-) 6 Electric hinge # with s Raceway harness # with The 4-pin connectors are not used here Copyright 009, SARGENT Manufacturing. All rights reserved. A77C - 5--9 TL- SARGuide 80 Series Rail 4 to 8-pin patch cable., raceway and electric hinge terminations and wire colors all match.. Typical raceway locations shown. Location may vary depending on door type. 3. 4 to 8-pin patch cable converts TL- 4-pin connector pins & to pins &. 4. Wire to pigtail harness assembly as shown. Then plug pigtail connector into hinge connector.