IntelliMold Systems OEM Integration: Van Dorn Revision Level: 002 Document Number:

Similar documents
Upgrade your blow molding machine with one of our two new state of the art machine control systems.

UPGRADE YOUR BLOW MOLDING MACHINE WITH ONE OF OUR TWO NEW STATE OF THE ART MACHINE CONTROL SYSTEMS.

Basic 3-Stage Control Applications & Reference. RJG, Inc. 2002, 2003, 2009

Automotive Application ET01 Software Revision A 12/06

CENTRIFEEDER ELECTRONICS

MAX-FIRE AND E-FIRE ELECTRONIC DISTRIBUTORS

PF3100 TROUBLESHOOTING SOLUTIONS TO COMMON PROBLEMS. v1.1 Revised Nov 29, 2016

MAGPOWR Spyder-Plus-S1 Tension Control

Servo and Proportional Valves

MI0559A OXY-BEVEL OPERATIONS MANUAL: Oxy-fuel contouring beveling head with manual tilt function.

Troubleshooting Bosch Proportional Valves

SP4 DOCUMENTATION. 1. SP4 Reference manual SP4 console.

Engel Injection Molding Machine VERTICAL CLAMP INSERT 330V/90 WP US. Data Sheet INSERT 330V/90 WP US - VERTICAL CLAMP / VERTICAL INJECTION

DG s Guide to Programming AEM EMS Electronic Boost Control V 2.01

COBB TUNING. AccessTUNER. USDM Mitsubishi Table Descriptions and Tuning Tips. Copyright 2008 Cobb Tuning Products, LLC. All Rights Reserved. P.

Mitsubishi EVO VII-IX Intercooler Waterspray System

SE-DUZ Direct-Drive All-Electric Series

Appendix 9: New Features in v3.5 B

The DPQ Series 2X Digital Injection Process Controller

Product Manual. Part Number: MVP-193 Mefi-6 ECU Revision: 1.0

FMVSS 126 Electronic Stability Test and CarSim

Using the Gratec Gasoline software

Volumetric Efficiency Diagnostics by Glen Beanard - Dec 29,

Motor Tuning Instructions

Installation, Operation, and Maintenance Manual CEMLINE CORPORATION

Preparing and programming of ESGI 2 LPG supply system manual

GENERAL The AuRACLE Engine Management System primary display provides a graphical representation of the following engine instrumentation:

All of the control valves that we install the Mk. 16IQ positioner on are factory calibrated for proper operation prior to shipment.

Injection Systems Alcohol Controller

three different ways, so it is important to be aware of how flow is to be specified

MAGNA T SERVO. 500 to 5,500 kn

MPT SERIES OPERATING MANUAL. Caution: To Operate this controller safely, use the Safe Operating Area Design Tool Online at

SmarTire TPMS Maintenance Hand Tool. Revision User Manual

*Shown with optional high pressure blowers

Application Note. First trip test. A circuit breaker spends most of its lifetime conducting current without any

Whizbang Jr. Installation Instructions

Bisnet Solutions for Tomorrow, Today! The Die Casting Process Planner. Users Manual. August 5, A Product By: Bisnet - 1 -

TECHNICAL PAPER 1002 FT. WORTH, TEXAS REPORT X ORDER

Product manual Oil Streak Sensor INTRODUCTION CONSTRUCTION. Master Sensor

VT-HACD-DPQ Digital Controller for electro-hydraulic Injection Molding Machines

University of Jordan School of Engineering Mechatronics Engineering Department. Fluid Power Engineering Lab

Eco-Propel TM Variable Speed Pump Kit Instruction and Operation Manual, P/N: , Revision 1

Model: AEM14 Analog Engine Monitor

Lingenfelter NCC-002 Nitrous Control Center Quick Setup Guide

SmarTire TPMS Maintenance Hand Tool. Revision User Manual

SHOCK ABSORBER/DAMPER TESTING MACHINE

PRESSURE SENSOR INSTRUCTIONS

Dealing with customer concerns related to electronic throttle bodies By: Bernie Thompson

CPi. CoiL PACK IGNiTioN FOR AViATiON. For 4,6 and 8 cylinder 4 stroke applications. Please read the entire manual before beginning installation.

The ROBUST Performer

TROUBLESHOOTING AND MAINTAINING ELECTRONIC KILN CONTROL SYSTEMS

Spartan Controls Millennium Compressor Control Panel Operating Philosophy

Device Description User Manual Logix MD+ Positioners with HART

Using an SMC-50 Solid-State Smart Motor Controller for Pump Protection

Diesel Fuel Challenges and Nanofiber Media Filtration Solutions

Hydraulic Proportional and Closed Loop System Design

Understanding the benefits of using a digital valve controller. Mark Buzzell Business Manager, Metso Flow Control

Rosemount 8800 Vortex Installation Effects

Cannondale Diagnostic Tool Manual

TurboGen TM Gas Turbine Electrical Generation System Sample Lab Experiment Procedure

Appendix A: Motion Control Theory

Operating and Installation Instructions

SE-3SCR-LM MANUAL MOTOR LOAD MANAGER

Eco-Propel TM Variable Speed Pump Kit Instruction and Operation Manual, p/n Revision 0

Basic Machine Interface Options

ITCEMS950 Idle Timer Controller - Engine Monitor Shutdown Isuzu NPR 6.0L Gasoline Engine

EEL Project Design Report: Automated Rev Matcher. January 28 th, 2008

Water/Methanol Failsafe

Application Engineering

INSTALLATION INSTRUCTIONS. Revision 3.1.1

Technical Information

ROW PRO DOWN PRESSURE

ICL Three Pump Controller

Section 55 Chapter 6

CURTIS TOLEDO. AF Series Compressors VS models with VFD WARNING

COMMUNICATIONS SETUP DBS STARTER PANEL

DRV-1. Step Motor Drive. User Manual Mentor Avenue Cincinnati, Ohio Tel (513)

Warnings and Cautions. Precision Flow Insertion Mass Flow Meter. Instruction Manual BULLETIN F-41-PFS FR# R

TrueGyde Microcoil. Author: Marcel Berard Co-Author: Philippe Berard

Introduction to hmtechnology

StepSERVO Tuning Guide

Basics of Electronic Indicators

Automated Seat Belt Switch Defect Detector

Tutorial. Running a Simulation If you opened one of the example files, you can be pretty sure it will run correctly out-of-the-box.

EcoNet and Flash Codes

Digital III Fueling Vehicle Control System

MID TONNAGE. Van Dorn Caliber


Using Advanced Limit Line Features

APPLICATION NOTE. Labeling Machine

Congratulations. You ve just purchased the most advanced flasher available on the market today. This

STR3. Step Motor Drive. User Manual

Model H30 Operation Manual

CRF450 Turbo 5B4CBD2o 19.2

Faraday's Law of Induction

CurveMaker HD v1.0 2Ki Programmable Ignition programming software

DYNAMOMETER CONTROLLER MODEL 5220 INSTRUCTION AND REFERENCE MANUAL

Vission 20/20 micro-controller. Operation and service manual

ECT Display Driver Installation for AP2 Module

Dynojet Research, Inc. All Rights Reserved. Optical RPM Sensor Installation Guide.

Transcription:

IntelliMold Systems OEM Integration: Van Dorn Revision Level: 002 Document Number: 7.5.1.0.30.002 The following information is for reference only. It is subject to change and may not be identical on all types of Van Dorn Controls. The following information has been gathered to help in start-up, set-up and troubleshooting any problems that have to do with the successful operation of the IntelliMold System on a Van Dorn Injection Molding Machine. 1

What is IntelliMold TM? IntelliMold TM is a unique process control method that provides measurements and control of pressure transition throughout the cavity in real time. This is achieved by generating a new process parameter called internal melt pressure, IMP. IMP is generated from real-time measurements, every 2 milliseconds, from a transducer in the nozzle extension and at the last place to fill in the cavity. The real-time value of the IMP is compared with the operator-entered set point and the hydraulics are manipulated in a manner to bring the actual value to the set point. The IMP replaces the need for boost, pack and hold profiles. In addition to the 2 pressure transducers, the cavity is also charged with 200 psi of air prior to the start of injection. We provide an air amplifier that will boost normal plant air between 50-150 psi to the specified 200 psi. The primary purpose for this is to give the transducers a known start point prior to the start of injection. An additional advantage of this pressure within the cavity is that it helps make the material more dense as it fills the cavity. Using this in conjunction with the material based control of injection provides parts with a more even density throughout the part. With this method and process control, each section of an injection molded part solidifies in an equal, pressurebalanced and stress free environment. You can t control that which you can t measure; yet, that is what we, the molders, have been trying to do for many years. - Milko Guergov 2

Fig. 1 Above screen is the conventional injection screen from a Pathfinder 5000 Control. Although it may very slightly, It is pretty common among the Pathfinder series. It is from this screen that you access the Intellimold System (GCP). Note: IntelliMold is also known as GCP on earlier systems. To navigate to the IntelliMold screens a.k.a. GCP, select Injection Options from the main injection screen. It is important to note that earlier versions of software would allow Peak Boost to limit IMP from obtaining required pressure. This has since been addressed but it is recommended that it be checked. You can do so by lowering peak boost to a value of 100psi while processing with IntelliMold (GCP). Verify you obtained the IntelliMold set point, If not enter maximum in/s and psi values allowed in this field. Attention: On some versions of software conventional set points may interfere with Intellimold operation. CUTOFF and PEAK BOOST have been known to interfere in the past. Although this problem has been addressed it is important to verify that In/Sec Pressure and Time setting do not effect Intellimold operation. 3

The Following is the Conventional Injection Options screen. You can access it by selecting the Injection Options button on the main Injection screen. From this screen you access the main IntelliMold a.k.a. GCP screen. It is done by highlighting GCP PROCESS and hitting ENTER. Depending on the machine their may be other options in this menu. A common option on the newer Van Dorn s is a Cavity Pressure Menu. Although our process utilizes a cavity pressure and/or temp transducer IntelliMold is not related to this cavity pressure transfer option. Fig. 2 Highlight GCP PROCESS by hitting the down arrow and then return. That will take you to the Main GCP Screen. Note there may be other options, depending on the equipment installed on the IMM. Also note that on future updates GCP will become IntelliMold. 4

Fig. 3 The values shown here are simply to scale the graph created by the interface. IMP = Internal Melt Pressure is the calculated control variable. INJ PRS = Injection Pressure is the actual hydraulic pressure. OUT VOLT = The Command Sent To Pressure Valve, normally 10 to 0 volts. CAV PRS = The transducer located in the cavity. SCR POS. = Screw Position is the conventional linear transducer. Its setting is based on the full travel of the injection ram for that machine. SCR VEL. = Screw Velocity should be set according to your set point located in the IntelliMold (GCP) Set-up Screen. IMP Control Values: There are three settable fields on this screen. The system is turned on or off, IMP pressure is set for a signal stage profile, and injection time is adjusted. If there is a need to use more than one segment of pressure during injection (other wise known as profiling) you must set your values in the IntelliMold (GCP) Profile screen. See page 7 Note: If you are unable to add a value in this screen you must re-scale the input values in the IntelliMold (GCP) Setup Screen. See page 8. You must also re-input your profile shown on page 67 This field will display actual IMP during injection or anytime a force is exerted on one or both transducers. There has been a problem in the past with Peak IMP displaying an incorrect value. This problem has been addressed and is corrected using a software fix. If you encounter this problem contact your IntelliMold representative. This field will display actual cavity pressure it is normal for a delay. Since the cavity transducer is usually at the last place to fill. This field will display actual Melt Pressure during injection and recovery, or anytime pressure is exerted on it. Note: These fields are not able to display negative values. A transducer that is in a negative range will show a zero on the interface. This field will capture the peak IMP Pressure. This field will capture the peak Cavity Pressure. This field will capture the peak Nozzle Pressure. 5

Fig. 4 Int IMP (Integral IMP) gives the ability to calculate 1 st Integral in a PSI vs. Time format. This is used to calculate Rheology. If you refer to the figure below it shows a typical IMP curve, as it would be displayed on the Main IntelliMold (GCP) Screen. By specifying a delay to start time and an active time you are able to calculate the area under the IMP line, or otherwise known as the 1 st integral. This example shows good reason for delay. Fig. 5 This red line shows in of active timer. The yellow shows all of the area that is calculated. 6

Fig. 6 The below segment is set up for a single injection profile. This means the machine will strive to keep IMP (Internal Melt Pressure) at a constant pressure throughout the entire injection stage. By doing this IntelliMold is able to keep an even density throughout a part. On this screen you have the ability to set up to ten segments of Pressure Vs Position. This screen works much like the Van Dorn Conventional profile screen with the exception of its psi. Value. The psi. Value used on this screen is the same used on the Main IntelliMold (GCP) Screen on page 4. Take into account that these values pertain to IMP (Internal Melt Pressure) and are calculated after the intensification ratio. If you have a hydraulic pressure of 1,000, the IMP value would be roughly 10,000 psi. Depending on the intensification ratio of your machine. Keep in mind that an intensification ratio of ten was used for this analogy and can vary depending on the machine. Fig. 7 (Left) Demonstrates the ability to do a four-segment profile with IMP pressure Vs Position. This profile is only active when IMP Control is on. 7

Built-in Ramp Fig. 9 No Ramp Fig. 10 Notice the built in ramp on figure 9, to eliminate any unwanted ramps in the Van Dorn control specify the start position and pressure as well as the end position and pressure. 8

This will display IMP actual during injection. This will display actual cavity pressure. This will display actual nozzle pressure. Fig. 8 Note: Zero should only be performed when transducers are free from pressure. In this field you are able to adjust the GAIN, RATE, RESET. Gain = Proportional Rate 85 = Derivative Reset = Integral The tuning values you assign in this field are used on the calculated process variable. (IMP) It is only used when IntelliMold (GCP) is turned on. AO Output is also known as process factor A. It is used to change the way IMP is calculated. 00.00% = PFA 1.00 25.00% = PFA 0.50 50.00% = PFA 0.00 75.00% = PFA +0.50 100.00% = PFA +1.00 See page 9 for more on PFA. In this field you can adjust Boost Volume. It has been placed here for easy access to velocity control without having to change back to conventional screens. 9

Process Factor A The following graphic depicts how PFA affects the IntelliMold process. The blue line represents cavity pressure; the red line represents nozzle pressure; the green line represents calculated Internal Melt Pressure (IMP). Notice that there are three separate scenarios for nozzle pressure. With PFA at 1, nozzle pressure is reduced when the cavity is introduced. With PFA at 0 there is no change in nozzle pressure. With PFA at +1 nozzle pressure is increased. 10

Process Factor A GCP (M&C) SITE CINCINNATI MILACRON Nozzle M.P. Nozzle M.T. GCP Process Control ler F.F Bias Cav. M.P. Cav. M.T. IMP Actual (Calculated) Σ Error PID Σ S. F. Set Point For screen) Valve Amp Operator Interface From Previous Page Hyd. Inj FRW Valve 11

IntelliMold (GCP) scaling fields. This is the section used to scale the IMP, Nozzle, and Cavity signals that come from the I.C.E. Box to the Analog I/O board of the Van Dorn Control. These three signals are 0-10volts, and the most common transducers used have a max limit of 20,000 psi. This may not always be the case though, so it is important to check the type of transducer running in the machine in question. Another important thing to note is that these fields are only to scale the values on the operator interface as a reference. They have no overall controls on the actual process. For instance, if a part was made with a IMP set-point of 10,000 psi and the scaling was set at 20,000 psi / 10v, for a 20,000 psi transducer, the IMP field would read roughly 10,000 psi and a part would be produced. If on the very next shot the scaling was cut in half to 10,000 psi / 10v and the set point remained the same with the very same transducer, the value would read 5,000 psi. However the machine would have exerted the exact same amount of force and an identical part would have been produced. Fig. 9 Max IMP should be set same as IMP scaling. The IntelliMold System requires a small pneumatic panel be used to pre-pressurize the cavity of the mold during injection. It utilizes the Digital Output board of the Van Dorn control. (See Fig 10) There are three outputs required to control the pneumatic panel. Timer 1 (as seen above) controls MP1 and timer 2 controls MP2, both normally closed solenoids located on the pneumatic panel. MPR is active whenever either solenoid is energized. MPR is a normally open solenoid designed to port any stored pressure to atmosphere after injection. 12

Fig. 10 As shown in this configuration, digital outputs 29, 30, and 31 on OUTPUT CARD 2 have been used to send the signal to energize the solenoids located on the pneumatic panel. **Note: Output address may vary.** Fig. 11 Address of output card Plug location on output card Contact location on plug 13

Fig. 11 I O O I Fig. 11 display the normal location for the digital I/O boards. However not every Van Dorn has the same configuration. It is important to check your machine s drawings. When an upgrade is done for the IntelliMold equipment, software must be written to select witch dry contacts are used. It is important that the company responsible for the upgrade has up-to-date information on any new features that might have been added, if not the possibility of using a contact that already might be utilized exists. Located on the left is a picture of the most common pneumatic panel used. It clearly shows the location of MP1 (GCP1), MP2 (GCP2), and MPR (GCPR). There are however more than one option of pneumatic panels available. For more information contact your IntelliMold representative. 14

Fig. 12 15

IntelliMold Technology Milko Guergov President of MGV and Inventor of IntelliMold Technology (734) 477-9344 (734) 231 6572 Mobil Who to contact at IntelliMold General IntelliMold Information Parts design options / development Press, part or mold evaluation / questions, Tool conversions / questions, Technical Service Scheduling trials, meetings or presentations, John Antos Vice President of Engineering (734) 477-9344 Materials and Process Development Gregg Kyuzin Vice President Materials and Process Development 734 477 9344 Data on installations (cycle time, scrap rate, etc.) Sales & Marketing Accounting Purchasing Human Resources Main Phone Number (734) 477-9344 Main Phone Number (734) 477-9344 Main Fax (734) 477-9345 IntelliMold Systems 4651 Platt Lane, Ann Arbor, Michigan 48108 intellimold.com / mgventerprises.com 16

Revision History Revision Description Revision Date Rel. Document Released 10/19/01 001 Updated with Collins & Aikman logo 1/9/02 002 Page 3 Added note to confirm settings for cutoff and peak boost to avoid interference with Intellimold set points 4/17/02 17