Ordering Information. Text PCB Power Relay G5RL. Low-profile Relay with Various Models. Power Relays

Similar documents
Ordering Information. Text PCB Power Relay G5LE

PCB Relay. Ordering Information. Compact, Low-cost 30-A Power Relay for PC Board or Panel-mounted Applications G8P - - VDC

PCB Relay. Ordering Information. SPST-NO Type Breaks 10-A Loads; SPST-NO + SPST-NC Type Breaks 8-A Load G6C - - VDC

Type Contact form Enclosure ratings Model Standard SPST-NO (Class A) Flux protection G5LA-1A Sealed

PCB Relay. Ordering Information. Compact, Low-cost 30-A Power Relay for PC Board or Panel-mounted Applications G8P - - VDC

PCB Relay. Contact form Terminal Single-side stable Single-winding latching

PCB Relay. Contact form Terminals Coil terminals Rated voltage Model SPST-NO #250 tab terminals PCB terminals 5, 12, 24 VDC G4A-1A

PCB Relay. New G8P. Ordering Information. Compact, Low-cost 30-A Power Relay for PC Board or Panel-mounted Applications G8P - - VDC

Single-pole 10A35VDC 0.8mm Contact Gap Power Relay : G5LE-G Single-pole 16A250VAC Power Relay : G5LE-E. Contact Form 10A 35VDC

PCB Relay RC FCC. Ordering Information. Fully Sealed Relay with High Impulse Dielectric for Use in Telecommunications Equipment

Load Resistive load (p.f. = 1) Inductive load (p.f. = 0.40, L/R = 7 ms) Rated load 5 A at 250 VAC, 30 VDC 2 A at 250 VAC, 30 VDC

PCB Relay. 2. Contact Form 2: DPDT 3. Terminal Shape None: PCB terminal F: Surface mount terminal

PCB Relay. Single-side stable EN60950/EN41003 PCB terminal G6S-2 G6SU-2 G6SK-2 G6S-2-Y Surface mounting. stable

PCB Relay RC+ Ordering Information. Subminiature Relay that Switches up to 5 A G6B VDC

Model Number Structure

Ordering Information. Text Surface-Mounting Signal Relay G6K

Applicable Terminal Relay Rated voltage Model G6D-F4B 12 VDC G6D-1A (see note) 24 VDC 12 VDC G6D-1A-AP (see note) 24 VDC G3DZ-F4B 12 VDC G3DZ-2R6PL

Type Contact form Model Plug-in socket/solder terminals Hermetically sealed 4PDT MY4H-US

Subminiature Basic Switch

Model Number Structure

Power PCB Relay. Type Contact material Contact form Construction Part number General purpose AgCdO SPDT Semi-sealed G2R-1

PCB Relay. Ordering Information. Surface Mounting DPDT Relay G6S

Safety Relay Unit. Ordering Information. Ideal for Safety Door and Emergency Stop Switch Circuits for Machines in European Countries

Mounting type Contact form PCB terminals Screw terminals Quick-connect terminals

Sealed type washable 1C H-1C-C 812H-1C-V 812H-1C-S (SPDT) F 812H-1C-C F 812H-1C-V F 812H-1C-S F

G6K. Surface Mounting Relay with the World s Smallest Mounting Area. Application Examples. Model Number Legend. Ordering Information

G7L. A High-capacity, High-dielectric-strength Relay Compatible with Momentary Voltage Drops. Application Examples. Model Number Legend

G7S Safety Relay. Ordering Information. Safety Relay conforming to EN standard G7S. Accessories Safety Relay Sockets

G7S. Ordering Information. Plug-In Safety Relay. Safety Relay for Machine Control Conforms to EN Standard. H Suitable for safety circuits in press

Low Signal Relay. To Order: Select the part number and add the desired coil voltage rating, (e.g., G6A-274P-ST-US-DC12).

Features. Type List. Ordering Information S - 1A - - C - Contact Rating

DPDT BTA12-2C-S-C BTA12-2C-S-CL BTA12-2C-S-CLM SPST-NO-DM BTA12-1X-S-C BTA12-1X-S-CL BTA12-1X-S-CLM

General Purpose Relays Power Relays. T9G series, DC coil 30A PCB Relay

Ordering Information. Motor Timer H2A. Miniature, High-performance Motor. Motor Timer H2A 1

Enclosed Switch. Ordering Information. Economical, High Utility Enclosed Switch. Model Number Legend D4MC- List of Models

General Purpose Relay

D2SW-AQ. Sealed Subminiature Basic Switch Conforming to IP67 (Excluding the terminals on terminal models) Model Number Legend

High-force: 230 g. Projected 7.3 mm General-purpose: 160 g. High-force: 230 g. Flat 4.3 mm General-purpose: 200 g.

AC 250V AC 250V AC 250V AC 250V DC 110V DC 110V DC 110V DC 110V Max. Allowable Current 15A 10A 10A 10A

881WP. Type List. Ordering Information 881 WP1-1A C - - C Basic series designation 4. C -- Contact material AgNi

Ordering Information. Snap Action Switch D2F. Subminiature Snap Action Switch D2F- Model Number Legend. Snap Action Switch D2F 31

Standard Plug-in/solder SPDT LY1 LY1F DPDT LY2 LY2F LY2Z LY2ZF 3PDT LY3 LY3F 4PDT LY4 LY4F PCB SPDT LY1-0 DPDT LY2-0 LY2Z-0

T75S5D Product Details

Model Number Structure

D2SW-P. Sealed Subminiature Basic Switch. Ordering Information D2SW-P

0.5 s to 30 h (30 s, 3 min, 30 min, 3 h, 30 h)

For full product information, visit Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page.

General Purpose Relay

Industrial Relay KML(1C, 2C)

TV-5, TV-8 rated 10mm flat power relays Silent type is available

Type Terminal Coil Contact form Model

Surface mounting, flush mounting, and DIN track mounting

General Purpose Relay

Type Plunger Switch height Operating force Model Without ground terminal With ground terminal. 5.0 mm General-purpose: 100 g 150 g

E bracket (see note 1) SPST-NO G7L-1A-TJ-CB G7L-1A-BJ-CB DPST-NO G7L-2A-T-CB G7L-2A-B-CB

3. Terminal Shape P : PCB terminals FS: Surface-mounting terminals, short FL : Surface-mounting terminals, long

H3DS-X - Solid State Two-Wire Timer

Power Contactor with Mirror Contacts

1 Form A 5A small size power relay for interface

TL RELAYS. TYPICAL APPLICATIONS Head lamp, Fog lamp, Fan motor, etc. ORDERING INFORMATION TYPES. High Load Relay for Smart Junction Box ACTL.

G9SA-TH. Two-Hand Controller. Ordering Information. Specifications. 45-mm Wide Two-hand Control Circuit. H Two-hand Controller, easy-to-connect

Model Number Structure

AUTOMOTIVE LOW PROFILE MICRO-ISO/MICRO-280 RELAY

Model Number Structure

TC RELAYS. TYPICAL APPLICATIONS Head lamp, Fog lamp, Fan motor, Defogger, Seat heater, etc. ORDERING INFORMATION. High Load Relay for Smart J/B ACTC

Safety-door Switch. Ordering Information

Application Support. Product Information. Omron STI. Support Engineers are available at our USA headquarters from

Mechanical Key Switch

Emergency Stop Switch A165E. Ordering Information. Mounting Aperture of 16 mm

The full feature relay includes the combination for rotary button or plain button or light or indicator flag.

D2HW. Sealed Ultra Subminiature Basic Switch. Ordering Information

D4BL. Protective Doors Are Locked Until Machines Completely Stop Operating. Guard Lock Safety-door Switch. Model Number Structure.

Selection Guide Automotive Relays

General Purpose Relays Industrial Relays. Power Relay RM 2/3/7

A165-E. Ordering Information. Emergency Stop Switch. For Panel Cutout of 16 mm

Scheda prodotto Relè Series E

Switching Power Supply

Scheda prodotto Relè Series B

D4BS. Safety-door Switch. Model Number Structure. Switch D4BS - S Operation Key D4BS - K. Ordering Information

RUC industrial relays of small dimensions

D2VW. Sealed Miniature Basic Switch. Ordering Information Model Number Legend D2VW- -

(with Class-1 AC resistive load) 3. G3PB-215B-2N-VD kW max. (25 A) G3PB-225B-3N-VD 2. G3PB-225B-2N-VD kw max. (35 A) G3PB-235B-3N-VD 2

Model Number Structure

Features. Emergency Stop Switch A22E. Install in 22-dia. or 25-dia. Panel Cutout. Safety Lock Mechanism to Prevent Misuse.

Product discontinuation. Notices. Discontinuation Notice of Safety Relay and Socket. G7S series, P7S series. Wire connection

Features. Type List A

Ordering Information. General-purpose Basic Switch X. Direct Current Switch with Built-in Magnetic Blowout. Model Number Legend

General Purpose Relay

5 mm contact pin pitch PCB or 95 series sockets

Miniature Enclosed Limit Switch D4MC. Ordering Information. Economical, General-Purpose, Enclosed Switch. H High precision and long life (10,000,000

6mm and 14mm Slim Interface Relay

Square D General Purpose Relays

B3F. Miniature, Space-saving Switch

Features. Type List 832A

Multiple Plunger Limit Switch

Model Number Structure

For full product information, visit Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page.

Tactile Switch. Ordering Information. A Wide Range of Models: 6 x 6 mm, 12 x 12 mm, Vertical, and High-force.

D4DS. Compact Interlock Safety Door Switch. Compact Safety Switch Saves Space and is Ideal for a Variety of Doors. Refer to Precautions on page 9.

D2SW. Sealed Subminiature Basic Switch Conforming to IP67 (Excluding the terminals on terminal models) Model Number Legend

Transcription:

Low-profile Relay with Various Models Low profile:.7 mm in height Clearance and creepage distance Between coil and contacts: 8 mm/8 mm Between contacts of the same polarity: 3 mm/4 mm Models with AC coil available. High-Inrush model available (Inrush peak currents up to 00 A) Silent model available (Approx. 2% ( db) less sound pressure than standard GRL-series Relay) RoHS Compliant Power Relays Ordering Information Classification Enclosure ratings Contact form Contact ratings Special function SPST-NO SPDT 6 A (high capacity) AC coil Flux protection --- GRL--E High inrush GRL-A-E-HR GRL--E-HR Silent GRL-A-E-LN 2 A GRL-A-LN Note: When ordering, add the rated coil to the model number. Example: GRL-A-LN 2 VDC Rated coil Model Number Legend GRL VDC (VAC) 2 3 4. Number of Poles : pole 2. Contact Form / Contact Construction None: SPDT A: SPST-NO 3. Classification None: 2 A E: 6 A (high capacity) 4. Special Function None: Standard HR: High inrush LN: Silent. Rated Coil Voltage Refer to Coil Ratings on page 2, 4 and 6. 37

Specifications Models with AC Coil Rated 24 VAC 00 VAC VAC / VAC 0 VAC 230 VAC / 240 VAC Rated current 0Hz (ma) 3.30 ma 0 ma.8 ma 6.2 ma 3.7 ma 3.00 ma 3.3 ma Rated current 60Hz (ma) 28.30 ma 6.88 ma.3 ma.70 ma 3.4 ma 2.76 ma 2.88 ma Coil resistance 443Ω 8,2Ω,600Ω 33,000Ω 47,600Ω Must operate Must release 7% max. of rated % min. of rated Max. 90% to 0% of rated Power consumption Approx. 0.7 VA Note:. The above items are measured at a coil temperature of 23 C. 2. The tolerance of rated current is +% / -%. 3. Power consumption drop was measured at 0Hz. 4. Coil resistance is provided as reference values. Characteristics Contact form Contact material Load Rated load Rated carry current Max. switching Max. switching current Max. switching power Failure rate (reference value) 38 SPDT Note: P level: λ60 = 0. x 0 6 operations Ag alloy (Cd free) Resistive load (cosφ=) 6 A at 20 VAC (NO) 6 A at 24 VDC (NO) A at 20 VAC (NC) A at 24 VDC (NC) 6 A (NO), A (NC) 20 VAC, 24 VDC 6 A (NO), A (NC) 4,000 VA, 384 W (NO),20 VA, W (NC) 40 ma at 24 VDC Contact resistance Operate time Release time Insulation resistance 00 mω max. ms max. ms max.,000 MΩ min. (at 00 VDC) Dielectric strength 6 A (NO), A (NC) Max. switching 6,000 VAC, 0/60 Hz for min between coil and contacts,000 VAC, 0/60 Hz for min between contacts of same polarity Impulse withstand 0 kv between coil and contacts (.2 x 0 µs) Vibration resistance Destruction: 0 to to 0 Hz,.-mm double amplitude Malfunction: 0 to to 0 Hz,.-mm double amplitude Endurance Mechanical: 0,000,000 operations min. (at 8,000 operations/h) Electrical: 0,000 operations min. (Resistive load, 6 A, 20 VAC, NO contact) (Resistive load, 6 A, 24 VDC, NO contact) (Resistive load, A, 20 VAC, NC contact) (Resistive load, A, 24 VDC, NC contact) Ambient temperature Operating: -40 C to 70 C (with no icing) Ambient humidity Operating: % to 8% Weight Approx. 0g Note:. Values in the above table are initial values. 2. The contact resistance is measured with A applied at VDC using a fall-of-potential method. 3. The insulation resistance is measured between coil and contacts and between contacts of the same polarity at 00 VDC.

Approved Standards UL 08 (File No. E4643)/CSA C22.2 (No.4) (File No. LR3928) GRL--E 24 to 240 VAC 6 A, 277 VAC General, 0,000 operations - NO 6 A, 20 VAC General, 0,000 operations - NO TV-, 2,000 operations - NO A300 Pilot Duty, 7 VA, 240 VAC, 30,000 operations - NO /2 Hp, VAC, 6,000 operations - NO 60 LRA/0 FLA, 20 VAC, 6,000 operations - NO A, 20 VAC General, 0,000 operations - NC A, 24 VDC Resistive, 0,000 operations - NC Power Relays VDE (EN680-) (License No. A282) GRL--E 24, 00, /, 0, 230/240 VAC (0 Hz) 6 A, 20 VAC,000 operations - NO Dimensions Note: All units are in millimetres unless otherwise indicated. GRL--E Four,.3±0. dia. (28.8) 2.7max. (2.) ±0..7 max. (.) ±0. ±0. 0. 0. 0.33 * Indicates average 3 4 39

Specifications High-inrush Models Rated VDC 2 VDC 24 VDC 48 VDC Rated current 80.0 ma 33.3 ma 6.7 ma 8.96 ma Coil resistance 62. Ω 360 Ω,440 Ω,38 Ω Must operate Must release Max. 70% of rated 0% of rated 30% of rated Power consumption Approx. 400 mw Approx. 430 mw Note:. The above items are measured at a coil temperature of 23 C. 2. The tolerance of the rated current is +0%. Contact Ratings Characteristics Contact form SPST-NO SPDT Contact material Ag alloy (Cd free) Load Resistive load (cosφ=) Rated load 6 A at 20 VAC 6 A at 20 VAC (NO) 6 A at 24 VDC 6 A at 24 VDC (NO) A at 20 VAC (NC) A at 24 VDC (NC) Rated carry 6 A 6 A (NO), A (NC) current Max. switching 20 VAC, 24 VDC Max. switching 6 A 6 A (NO), A (NC) current Max. switching 4,000 VA, 384 W (NO) 4,000 VA, 384 W (NO), power,20 VA, W (NC) Failure rate 00 ma at 0 VDC (reference value) Note: P level: λ60 = 0. x 0 6 operations Contact resistance Operate time Release time Insulation resistance 00 mω max. ms max. ms max.,000 MΩ min. (at 00 VDC) Dielectric strength 6 A (NO), A (NC) Max. switching 6,000 VAC, 0/60 Hz for min between coil and contacts,000 VAC, 0/60 Hz for min between contacts of same polarity Impulse withstand 0 kv between coil and contacts (.2 x 0 µs) Vibration resistance Destruction: 0 to to 0 Hz,.-mm double amplitude Malfunction: 0 to to 0 Hz,.-mm double amplitude Endurance Mechanical: 0,000,000 operations min. (at 8,000 operations/h) Electrical: 0,000 operations min. (Resistive load, 6 A, 20 VAC, NO contact) (Resistive load, 6 A, 24 VDC, NO contact) (Resistive load, A, 20 VAC, NC contact) (Resistive load, A, 24 VDC, NC contact) Ambient temperature Operating: -40 C to 8 C (with no icing) Ambient humidity Operating: % to 8% Weight Approx. 0g Note:. Values in the above table are initial values. 2. The contact resistance is measured with A applied at VDC using a fall-of-potential method. 3. The insulation resistance is measured between coil and contacts and between contacts of the same polarity at 00 VDC. 40

Approved Standards UL 08 (File No. E4643)/CSA C22.2 (No.4) (File No. LR3928) GRL-(A)-E-HR to 48 VAC 6 A, 277 VAC General, 0,000 operations - NO 6 A, 20 VAC General, 0,000 operations - NO TV-, 2,000 operations - NO A300 Pilot Duty, 7 VA, 240 VAC, 30,000 operations - NO /2 Hp, VAC, 6,000 operations - NO 60 LRA/0 FLA, 20 VAC, 6,000 operations - NO A, 20 VAC General, 0,000 operations - NC A, 24 VDC Resistive, 0,000 operations - NC Power Relays VDE (EN680-) (License No. A282) GRL-(A)-E-HR, 2, 24, 48 VDC 6 A at 20 VAC cosφ=,000 operations - NO 240 VAC 00 A (0-P) Steady 0 A (rms) 0,000 operations - NO 240 VAC 0 A (0-P) Steady A (rms) 0,000 operations - NO Dimensions Note: All units are in millimetres unless otherwise indicated. Four,.3±0. dia. GRL-A-E-HR (28.8)* 2.7 max. (2.)*.7 max. (.)* ±0. ±0. ±0. 3 4 8 6 0. 0. 0.33 * Indicates average GRL--E-HR Four,.3±0. dia. ±0. ±0. (28.8)* 2.7 max. (2.)* ±0. ±0..7 max. (.)* 2 3 4 0. 0. 8 7 6 0.33 * Indicates average 4

Specifications Silent Models Rated VDC 2 VDC 24 VDC Rated current 06.0 ma 44.2 ma 22. ma Coil resistance 47.2 Ω 272 Ω,086 Ω Must operate Must release Max. Power consumption 70% of rated 0% of rated 0% of rated Approx. 30 mw Note:. The above items are measured at a coil temperature of 23 C. 2. The tolerance of the rated current is +0%. Characteristics Contact form SPST-NO SPDT Contact material Ag alloy (Cd free) Load Resistive load (cosφ=) Rated load 2 A at 20 VAC 6 A at 20 VAC 2 A at 24 VDC 6 A at 24 VDC Rated carry 2 A 6 A current Max. switching 20 VAC, 24 VDC Max. switching 2 A 6 A current Max. switching 3,000 VA, 288 W 4,000 VA, 384 W power Failure rate 00 ma at VDC (reference value) Note: P level: λ60 = 0. x 0 6 operations Item Standard High capacity Contact resistance Operate time 00 mω max. ms max. Release time ms max. Insulation,000 MΩ min. (at 00 VDC) resistance Dielectric strength 6,000 VAC, 0/60 Hz for min between coil and contacts,000 VAC, 0/60 Hz for min between contacts of same polarity Impulse withstand 0 kv between coil and contacts (.2 x 0 µs) Vibration Destruction: 0 to to 0 Hz, resistance.-mm double amplitude Malfunction: 0 to to 0 Hz,.-mm double amplitude Endurance Mechanical: Mechanical:,000,000 operations,000,000 operations min. (at 8,000 min. (at 8,000 operations/h) operations/h) Electrical: Electrical:,00,000 operations 0,000 operations (Resistive load, (Resistive load, 2 A, 20 VAC) 6 A, 20 VAC) (Resistive load, (Resistive load, 2 A, 24 VDC) 6 A, 24 VDC) Ambient Operating: -40 C to 8 C temperature (with no icing) Ambient humidity Operating: % to 8% Weight Approx. 0g Note:. Values in the above table are initial values. 2. The contact resistance is measured with A applied at VDC using a fall-of-potential method. 3. The insulation resistance is measured between coil and contacts and between contacts of the same polarity at 00 VDC. 4. The release time is value with a diode attached. 42

Approved Standards UL 08 (File No. E4643)/CSA C22.2 (No.4) (File No. LR3928) GRL-A-LN to 24 VAC 2 A, 20 VAC Resistive, 00,000 operations 2 A, 24 VDC Resistive, 00,000 operations TV-8, 2,000 operations GRL-A-E-LN 6 A, 20 VAC Resistive, 0,000 operations 6 A, 24 VDC Resistive, 0,000 operations TV-8, 2,000 operations Power Relays VDE (EN680-), EN6006) (Licence No. A282) GRL-A-LN, 2, 24VDC 2A, 20VAC cosφ= (60,000 operations) 2A, 24VDC (0ms) (00,000 operations) 230VAC, 70A (0-P) Steady A (ms) (,000 operations) 20VAC, 00A (0-P) Steady 3A (ms) (0,000 operations) 20VAC, 40A (0-P) Steady A (ms) (0,000 operations) GRL-A-E-LN 6A, 20VAC cosφ= (30,000 operations) 6A, 24VDC (0ms) (40,000 operations) 230VAC, 70A (0-P) Steady A (ms) (,000 operations) 20VAC, 00A (0-P) Steady 3A (ms) (0,000 operations) 20VAC, 40A (0-P) Steady A (ms) (0,000 operations) Engineering Data Distribution of Sound Pressure When Operating When Releasing Quantity 0 40 30 0 Quantity 0 40 30 0 Measuring Conditions Sample: GRL-A-LN (N=00) Measuring range: A characteristics, Fast, Max. hold Coil : 2 VDC Coil connected parts: Diode Background noise: Approx. 30 db Measuring environment: At normal temperature and humidity 0 ~36 ~38 ~40 ~42 ~44 ~46 ~48 ~0 ~2 ~4 ~6 Sound pressure (db) 0 ~36 ~38 ~40 ~42 ~44 ~46 ~48 ~0 ~2 ~4 ~6 Sound pressure (db) Relay 0 mm Sponge Microphone 43

Dimensions Note: All units are in millimetres unless otherwise indicated. GRL-A-LN Four,.3±0. dia. (28.8) 2.7max. (2.) ±0..7 max. (.) ±0. ±0. 0. 0. 0.33 * Indicates average 3 4 GRL-A-E-LN Six,.3±0. dia. holes (28.8) 2.7 max. (2.) ±0..7 max. (.) ±0. ±0. 0. 0. 0.33 Indicates average 3 4 8 6 Mounting When mounting a GRL-LN Relay (Silent Relay) on a PCB, use a diode for surge absorption for the coil. Disclaimer: All technical performance data applies to the product as such; specific conditions of individual applications are not considered. Always check the suitability of the product for your intended purpose. OMRON does not assume any responsibility or liability for noncompliance herein, and we recommend prior technical clarification for applications where requirements, loading, or ambient conditions differ from ALL DIMENSIONS SHOWN ARE IN MILLIMETRES. To convert millimetres into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.0327. CAT. No. K32-E2-0-X 44