Operating instructions Safety foot switches T.FH UEDR.. 1. About this document. Content

Similar documents
Operating instructions Solenoid interlock TKM/TKF. 1. About this document. Content

Operating instructions Solenoid interlock EX-AZM About this document. Content

Operating instructions Safety sensor BNS About this document. Content. 6 Disassembly and disposal 6.1 Disassembly Disposal...

Operating instructions Pull-wire emergency-stop switches EX-ZQ About this document. Content

Operating instructions Solenoid interlock AZM 161../.. 1. About this document. Content

Operating instructions Solenoid interlock AZM 161../.. 1. About this document. Content

Operating instructions Switching cushion with safety function SSG-SK. 1. About this document. Content

Operating instructions Solenoid interlock AZM /.. 1. About this document. Content

Operating instructions Trapped key system SHGV / SVE / SVM. 1. About this document. Content

Operating instructions Actuator and Emergency exit AZ/AZM 200-B30 AZ/AZM 201-B About this document. Content

Operating instructions Safety sensor EX-CSS About this document. Content. 7 Disassembly and disposal 7.1 Disassembly Disposal...

Operating instructions Solenoid interlock AZM 170

Encontrará el manual de instrucciones actual en su idioma oficial de la UE en nuestra página de Internet www. schmersal.net.

Encontrará el manual de instrucciones actual en su idioma oficial de la UE en nuestra página de Internet www. schmersal.net.

Operating instructions Solenoid interlock AZM About this document. Content

Operating instructions Solenoid interlock AZM About this document. Content

Operating instructions Solenoid interlock AZM About this document. Content

Ordering details. Approval. Classification. Global Properties :18:33h. Solenoid interlock / AZM 161

AZM 161SK 12/12RKED/TU 024

Solenoid interlock AZM 200 The non-contact interlock.

Safety door-handle system STS

Solenoid interlocks AZM 190 range. 128 Schmersal ,3 4,5 M20 17,5 23,5

Datasheet - AZ ZUEK Safety switch with separate actuator / AZ 3350

Solenoid interlocks AZM 161 range Schmersal. a 5,5. Pg11/M16x1,5

Datasheet - TV8S /20Z Safety switch for hinged guards / Hinge safety switch / TV8S 521

Technical data. Standards: IEC/EN ; EN ISO ; EN 1088; BG-GS-ET-19

Solenoid interlocks AZM 170 range. 98 Schmersal 22 8,2 60. ø4,2. ø Pg 11

Technical data. Standards: IEC/EN BG-GS-ET-15

Safety Sensor CSS 180 Product Information

Installation and Operating Instructions

Solenoid interlocks AZM 415 range. 134 Schmersal 29,5 6,5 24,7. 8,6 Pg 13,5 46,5 24,5

Installation and Operating Instructions

PROTECT SRB s Safety relay modules with intrinsically safe monitoring circuits Ex i L-protection for ATEX zones 1, 2, 21 and 22.

Safety Switches with Separate Actuator SKC

AC 100. Operating instructions Pneumatic Crimper AC 100. Date of issue: 05/2010. Keep for future use!

ZB0050 / ZB0051 ZB0070 / ZB0071

Technical data. Standards: IEC/EN EN 574 EN 418. powder-coated Protection class: IP 65. Cable section: max. 1.5 mm V I the :

Ex m Solenoid Operator Type 0519

SEPK 02.0 / SEPG 05.3 / SEP 01.0 / SEP 01.4 / SEPLC 05.2 / SEP 07.0 / SEP Operating instructions Two-hand control panel

FL series position switches

Operating Instructions

Safety switches with solenoid and separate actuator

Online data sheet. i15-em0123 Lock i15 Lock SAFETY LOCKING DEVICES

Giving reliability and cost effectiveness a lift. EKKE-Bas single-girder and ZKKE-Bas double-girder overhead travelling cranes EKKE ZKKE.

Safety rope switches with reset for emergency stop

Limit Switch - Safety Type with pull button reset Plastic Body IP65 and Metal Body IP66

S840, S845, S846 Series Single-break changeover, NC or NO contacts, positive opening operation and wiping action Catalogue D40.en

Safety switches with separate actuator

Position switches FD series

RSC09 RSC16 RSC22 RSC38 RSC43 RSC63 RSC-AUX

Operating Instructions

Technical data. Rated operating current/voltage I e /U e : AC-15: 2 A / 24 VAC DC-13: 1 A / 24 VDC Thermal test current I the : 2.

Single foot switches PX and PA series

Operating Instructions

SG-B1 SERIES / SG-A1 SERIES

SFS-UFS Single Foot Switches

Control Equipment. ATHEX bvba Tel: +32 (0) Fax: +32 (0) Alpenroosbaan 2, 2900 Schoten, België

Contactors. CH1130/02 Series Single pole high-voltage contactor up to 3 kv Catalogue C170.en. Connect - Contact - Control

Installation Instructions (Translation) Marking. Description. Danger, warning and note symbols. Technical data. ANTARES ExtSet.

Operating Instructions (Translation)

Technical Documentation

Type 0283, Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies

EStrong-series Emergency Stop

Safety rope switch with reset for emergency stop

Safety switches for hinged doors

Safety switches for hinges

2-PHASE STEPPING MOTOR DRIVER FE Z5 DISPENSE

Support T10552 T10595 T40386

Safety rope switch without reset for simple stop

Ordering details. BDF 100-➀-➁-➂-ST No. Option Description. ➀ 20 2 NO contacts 11 1 NO contact / 1 NC contact ➁ Selection of the actuator ➂

PRODUCT SPECIFICATION. Foot Switches. Series.

Oil-free piston compressors KK and piston vacuum pumps KV

F E - Electromagnetic Safety Switch With Separated Actuator. 1 Code Construction. Casing: P: Plastic casing

Position switches FR series

Floor and fine adjustment switches

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-Way Solenoid Valve 2/2-Wege-Magnetventil Électrovanne à 2/2 voies

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies

S826, S926 Series Dual changeover switches with positive opening operation and wiping contacts Catalogue D26.en

Contactors. CL1115/02, CL1215/02, CL1315/02 1, 2 and 3 pole AC and DC NO contactors for voltages up to 1,500 V Catalogue C25.en

Safety switches with separate actuator

INSTRUCTION MANUAL RELAY FOR ON LOAD TAP CHANGER APPLICATIONS OR-25 5COR OR25 REV03

D4DL. Guard Lock Safety-door Switch. Ordering Information. Model Number Legend Switches D4DL- -

These operating instructions apply for: NCX 380 NCZ 300 NCX 480 NCZ 370 NCX 580 L NCZ 480 NCX 660 K NCZ 560 NCZ 660 NCZ 800

HS6B Series Subminiature Interlock Switch

Operating Instructions

Installation Instructions

D4DL. Guard Lock Safety-door Switch. Model Number Structure

Instruction manual Electric glass door lock Touch-to-open

Command devices Pull-wire emergency stop switches One-side operation ZS 71 range Schmersal Industrial Switchgear.

UV- TECHNOLOGY. Technical Documentation ELC N6 / ELC N8 / ELC N10

panasonic.net/id/pidsx/global Solve issues related to machine safety and other safety measures with a safety door switch with key!

LK Position Switches TECHNICAL DATASHEET.

RFN Series Service and Parts

Safety Limit Switches

GEIGER-GJ56.. with mechanical end stop For Venetian blinds and exterior blinds

Safety switches with solenoid and separate actuator

Switches with manual reset

Operating Instructions

Single foot switches - PX and PA series

Hinged Safety Door Switch

Transcription:

1. bout this document EN Operating instructions............pages 1 to 6 Original 1.1 Function This operating instructions manual provides all the information you need for the mounting, set-up and commissioning to ensure the safe operation and disassembly of the safety switchgear. The operating instructions must be available in a legible condition and a complete version in the vicinity of the device. 1.2 Target group: authorised qualified personnel ll operations described in this operating instructions manual must be carried out by trained specialist personnel, authorised by the plant operator only. Please make sure that you have read and understood these operating instructions and that you know all applicable legislations regarding occupational safety and accident prevention prior to installation and putting the component into operation. The machine builder must carefully select the harmonised standards to be complied with as well as other technical specifications for the selection, mounting and integration of the components. 1.3 Explanation of the symbols used Information, hint, note: This symbol is used for identifying useful additional information. 11.2016 / 1011081 / G Content 1 bout this document 1.1 Function...1 1.2 Target group: authorised qualified personnel....1 1.3 Explanation of the symbols used...1 1.4 ppropriate use...1 1.5 General safety instructions...1 1.6 Warning about misuse...1 1.7 Exclusion of liability...2 2 Product description 2.1 Ordering code...2 2.2 Special versions....2 2.3 Destination and use...2 2.4 Technical data...3 2.5 Safety classification...3 3 Mounting 3.1 Dimensions...3 4 Electrical connection 4.1 General information for electrical connection....3 4.2 Contact variants....4 5 Set-up and maintenance 5.1 Functional testing....4 5.2 Maintenance...4 6 Disassembly and disposal 6.1 Disassembly....4 6.2 Disposal...4 7 EU Declaration of conformity Caution: Failure to comply with this warning notice could lead to failures or malfunctions. Warning: Failure to comply with this warning notice could lead to physical injury and/or damage to the machine. 1.4 ppropriate use The products described in these operating instructions are developed to execute safety-related functions as part of an entire plant or machine. It is the responsibility of the manufacturer of a machine or plant to ensure the correct functionality of the entire machinery or plant. The safety switchgear must be exclusively used in accordance with the versions listed below or for the applications authorised by the manufacturer. Detailed information regarding the range of applications can be found in the chapter "Product description". 1.5 General safety instructions The user must observe the safety instructions in this operating instructions manual, the country-specific installation standards as well as all prevailing safety regulations and accident prevention rules. Further technical information can be found in the Schmersal catalogues or in the online catalogue on the Internet: www.schmersal.net. The information contained in this operating instructions manual is provided without liability and is subject to technical modifications. There are no residual risks, provided that the safety instructions as well as the instructions regarding mounting, commissioning, operation and maintenance are observed. 1.6 Warning about misuse In case of improper use or manipulation of the safety switchgear, personal hazards or damages to machinery or plant components cannot be excluded. The relevant requirements of the standard EN ISO 119 must be observed. EN 1

1.7 Exclusion of liability We shall accept no liability for damages and malfunctions resulting from defective mounting or failure to comply with this operating instructions manual. The manufacturer shall accept no liability for damages resulting from the use of unauthorised spare parts or accessories. For safety reasons, invasive work on the device as well as arbitrary repairs, conversions and modifications to the device are strictly forbidden; the manufacturer shall accept no liability for damages resulting from such invasive work, arbitrary repairs, conversions and/or modifications to the device. 2. Product description 2.1 Ordering code This operating instructions manual applies to the following types: TFH 232-➀ 1-pedal safety foot switch No. Option Description ➀ 11UED 1 NO / 1 NC UED 2 NO / 2 NC T2FH 232-➀ 2-pedal safety foot switch No. Option Description ➀ 11UED/11UED 2 NO / 2 NC UED/UED 4 NO / 4 NC 11/UED 3 NO / 3 NC UED/11 3 NO / 3 NC Design/Operating principle: overlapping contacts with pressure point and latching (UED) epresentation Condition Function 0 1 0 0 0 Not actuated ctuated up to pressure point Pushed-through Unlock No authorised operation Safety release No authorised operation No authorised operation* * Switch-on impulse during the unlocking operation must be suppressed by means of measures at control technology level. For a single-channel connection, a jumper connection must be fitted between the contacts (not included in delivery). The non-safety-related pedal of the 2-pedal safety foot switch does not have the overlapping and latching functions. Only if the information described in this operating instructions manual are realised correctly, the safety function and therefore the compliance with the Machinery Directive is maintained. The user must evaluate and design the safety chain in accordance with the relevant standards and the required safety level. 2.2 Special versions For special versions, which are not listed in the order code below 2.1, these specifications apply accordingly, provided that they correspond to the standard version. The entire concept of the control system, in which the safety component is integrated, must be validated to the relevant standards. 2.3 Destination and use These robust safety foot switches are particularly suitable for industrial applications. ll safety foot switches are mounted with a shield to protect against unintentional operation. When the foot pedal is actuated to as far as the pressure point, the NO contact is closed. If, in case of danger, the pedal is actuated beyond the pressure point, then the positive break NC contact is opened and mechanically latched. The mechanical latching is realised through a slider and a spring, which are mounted in an enclosure. The reset operation is carried out by means of the blue pushbutton, which is located in the top of the cover. This button pushes on the slider, which is returned to its original position due to this action. The reset button is covered with a rubber cap, which protects the inside of the foot switch enclosure against humidity and soiling. 2 EN

2.4 Technical data Standards: IEC 60947-5-1, DIN VDE 0660-200, BG-GS-ET-15 Material of the enclosure, cover and protective shield: aluminium Enclosure coating: powder-coated thermoplastic Material of the pedal: glass-fibre reinforced thermoplastic Mechanical data Execution of the electrical connection: screw terminals Cable section: 2.5 mm² (incl. conductor ferrules) Cable entry: 1-pedal: 1 x M20 x 1.5; 2-pedal: 2 x M25 x 1.5 Mechanical life: > 1,000,000 operations Switching frequency: max. 1/s esistance to shock: 30 g / 11 ms esistance to vibration: 10 150 Hz (0.35 mm / 5 g) mbient conditions mbient temperature: 25 C +60 C Storage and transport temperature: 25 C +85 C elative humidity: 30% 95% - no condensation - no icing Protection class: IP65 Overvoltage category: III Degree of pollution: 3 Electrical data Execution of the control element: NC contact, NO contact Switching principle: Slow action switching contacts ated impulse withstand voltage U imp : 6 kv ated insulation voltage U i : 500 V Thermal test current I the : 10 Utilisation category: DC-: 24 V / 1 ; C-15: 230 V / 4 equired short-circuit current: 1000 Max. fuse rating: 6 gg D-fuse Dimensions: 1-pedal: 170 x 189 x 274 mm; 2-pedal: 295 x 189 x 274 mm 3. Mounting 3.1 Dimensions ll measurements in mm. 274 274 with 1 foot pedals M6 170 with 2 foot pedals 255 M6 49 45 207 M25x1,5 2,2 84 48 69 45 33 100 189 2,2 84 33 100 Openings shall be closed by equipment rated for enclosure types: 3, 3, 3X, 3S, 3SX, 3X, 5, 4, 4X, 6, 6P, 12 or. Use 105 C wires/cables only. 75 174 125 295 75 48 69 189 2.5 Safety classification Standards: ISO 849-1 B 10D (NC contact): 100,000 Service life: 20 years 4. Electrical connection 4.1 General information for electrical connection MTTF D B10D dop x hop n x 3600 s/h op 0,1 x n op t cycle The electrical connection may only be carried out by authorised personnel in a de-energised condition. (Specifications can vary depending on the application-specific parameters h op, d op and t cycle as well as the load.) If multiple safety components are wired in series, the Performance evel to ISO 849-1 will be reduced due to the restricted error detection under certain circumstances. The contact labelling can be found in the wiring compartment of the switch. For the cable entry, suitable cable glands with an appropriate degree of protection must be used. The cables must be laid correctly in the wiring compartment of the switch. For foot switches with 1 foot pedal, the M20 x 1.5 cable entry is available, for foot switches with 2 foot pedals, 2x M25 x 1.5. The non-used cable entry must be sealed with blanking plugs. fter wiring, the wiring compartment of the switch must definately be cleaned (e.g. removal of cables residues), considering that foreign bodies can affect the switching behaviour. The tightening torque for the cover screws is min. 1.8 Nm. EN 3

4.2 Contact variants The contacts are shown in a non-actuated condition. with 1 foot pedals 1 NO / 1 NC 2 NO / 2 NC with 2 foot pedals 2 NO / 4 NC (T2FH-232-11UED/11UED) 5. Set-up and maintenance 5.1 Functional testing The safety function of the safety components must be tested. The following conditions must be previously checked and met: 1. Check the integrity of the cable entry and connections 2. Check the switch enclosure for damage 3. Check the functionality of the switch by actuating the safety foot switch 5.2 Maintenance The safety function (switching) of the safety foot switch must be tested at regular intervals. Possible soiling accumulated below the foot pedal must be removed. regular visual inspection and functional test, including the following steps, is recommended: Check the switch enclosure for damages Check the cable entries and the wire connections Damaged or defective components must be replaced. 6. Disassembly and disposal 4 NO / 4 NC (T2FH-232-UED/UED) 6.1 Disassembly The safety switchgear must be disassembled in a de-energised condition only. 6.2 Disposal The safety switchgear must be disposed of in an appropriate manner in accordance with the national prescriptions and legislations. 3 NO / 3 NC (T2FH-232-11/UED) 3 NO / 3 NC (T2FH-232-UED/11) Key positive break NC contact left pedal right pedal 4 EN

7. EU Declaration of conformity EU Declaration of conformity Original SCHMES Industrial Switchgear (Shanghai) Co., td. Cao Ying oad 3336 201712 Shanghai / Qingpu P.. CHIN http://www.schmersal.com.cn We hereby certify that the hereafter described components both in their basic design and construction conform to the applicable European Directives. Name of the component: Type: See ordering code Description of the component: Foot switch for safety functions elevant Directives: Machinery Directive ohs-directive 2006/42/EC 2011/65/EU pplied standards: DIN EN 60947-5-1:2010, DIN EN ISO 849-1:2016 Person authorized for the compilation of the technical documentation: Oliver Wacker Möddinghofe 30 479 Wuppertal Place and date of issue: Shanghai, October 28, 2016 SISS-TFH232-G-EN uthorised signature Zhen iu Managing Director DE 5

K.. Schmersal GmbH & Co. KG Möddinghofe 30, D - 479 Wuppertal Postfach 24 02 63, D - 432 Wuppertal Telefon +49 - (0)2 02-64 74-0 Telefax +49 - (0)2 02-64 74-1 00 E-Mail: info@schmersal.com Internet: http://www.schmersal.com Production site: SCHMES Industrial Switchgear (Shanghai) Co., td. Cao Ying oad 3336 201712 Shanghai / Qingpu, P..CHIN Phone: +86--63 75 82 87 Fax: +86--69 43 98 E-Mail: info@schmersal.com.cn Internet: http://www.schmersal.com.cn 施迈赛工业开关制造 ( 上海 ) 有限公司地址 : 上海市青浦区漕盈路 3336 号邮编 :201712 电话 :0-63 75 82 87 传真 :0-69 43 98 网址 http://www.schmersal.com.cn