Boost-A-Break - Break Tank & Booster Sets

Similar documents
Pent-A-Boost Compact Domestic Booster Sets

Operating & Maintenance Manual Break Tank & Pump Set Model BTAB Arrow Valves

Operating & Maintenance Manual Compact Domestic Booster Set Model BTAF Arrow Valves

Installation & Technical Guide. Domestic & Commercial.

ScubaTank ScubaT Pump and tank system Combined variable speed pump and storage system

POWERBOOST. PRO Range. Clean Water Booster Sets. powerboost.ie

RE-PR3-E-86&105 3-Phase Panel Mount 86 and 105kW

SDS Enclosed Star-Delta Starter User Guide


Central Battery Systems Loadstar AC/DC Systems

Lowara UK Variable Speed Booster Sets

CBU144. Compact Booster Unit - single pump To ensure the quality of potable water according to EN1717. Product specification sheet

ECONOPLATE BV SERIES HOT WATER SERVICE PACKAGED HEAT EXCHANGERS WITH THERMAL STORES

ADS7 AC Contactor Starters

The pumps shall be Oil Free and Variable speed controlled by Pressure Transducer, PLC and inverter.

Phoenix Inverter

Duplex Commercial Pressurizer -DCP

Open Chassis Star-Delta Starter User Guide

VSPS PACKAGE BOOSTER SYSTEM (END SUCTION PUMP DESIGN) FEATURES T Y P E

M Series Condensate Recovery Unit

The pumps shall be Oil Free and Variable speed controlled by Pressure Transducer, PLC and inverter.

AQUAMATIC HY-AV 2020Plus SERIES

Power Systems Trainer

M3770: SOLENOID CONTROLLED / ELECTRICALLY POSITIONED VALVE - STEP BY STEP VALVE

BRSDRIVE ITT. Goulds Pumps. S-Drive. Simplex Variable Speed Submersible Pump Controller. Engineered for life

Ultra-compact, variable speed twin and triple pump booster sets

HGM501 Gen-set Controller USER MANUAL. Smartgen Technology

World Class Power Solutions. Rectifiers. For Stationary Battery Systems in Nuclear Power Plants

D M S 760 C01 A A 1 1

Technical data sheet VH UL. Digital Energy Uninterruptible Power Supply. GE Digital Energy Power Quality

COLD WATER BOOSTER SETS

Features: Available in horizontal and vertical units

Emergency lighting units EM converterled. EM converterled ST 90 V SELFTEST series

Aquavar e-abii. TECHNICAL BROCHURE BAQUAeABII VARIABLE SPEED CONSTANT PRESSURE SYSTEMS

The Mikrofill Electronic Filling Device. (EFD)

Each pump shall be equipped with carbon/graphite vanes. A vacuum relief valve shall be incorporated into the design of the pump.

Pump Station. Ama-Porter CK Pump Station. Type Series Booklet

Zip FlushMaster Surface mounted sensor

ALTI-NEXIS V OPERATING LIMITS APPLICATIONS ADVANTAGES. Flow rates up to: 320 m 3 /h Delivery head up to: Maximum operating pressure:

R2F Compact Commissioning & 4 Port Control Valve Fan Coil Unit Valve Set Module

OPERATING AND MAINTENANCE MANUAL. Primary Current Injection Test Set. 750ADM-H mk2

Pressure Boosting Systems Multiple-Pump Units

Solar Thermal. Grant Solar Pump Station Installation & Servicing Instructions

Réf GB / e ALTERNATORS. LSA Pole. Electrical and mechanical data

VERTICAL MULTISTAGE PUMP SETS

Datasheet. Flamcomat - Pressureless Expansion System

GSL30D. Main Features Frequency Hz 50 Voltage V 230 Power factor cos ϕ 0.8 Phase and connection 3

GSW22P. Main Features Frequency Hz 50 Voltage V 230 Power factor cos ϕ 1 Phase and connection 1

Powerterm L120C Single Output PSU/Battery Chargers Model C2199A-1 (12V/8A) or Model C2199A-2 (24V/6A)

VT Oil-Free Range Operators Handbook

INFRESCO 2KW VARIABLE CONTROLLER Issue 3

VTZ variable speed Reciprocating compressors

Operating & Maintenance Manual Tap Box & Tap Guard Arrow Valves Arrow Valves Ltd

RE-PR1-F 1-Phase Din-Rail Mount 1.5, 3 & 6kW

VERTICAL IN-LINE PUMP

Emergency lighting units EM converterled. EM converterled ST 50 V SELFTEST series

TAG2A TAG3A. Series kwm 1500/1800 rpm kwm 1500/1800 rpm ElectropaK. Ratings. Basic technical data

MGE TM Galaxy TM 7000 GFC

RVD110 RVD G2381en. Installation. Commissioning

MODEL 540 USER MANUAL INCORPORATING MODEL 530 TEMPERATURE CONTROLLER

GMN - 22P 29/07/2016 GMN - 022P (ACP KPR) Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3

2800 Series 2806A-E18TAG1A Diesel Engine ElectropaK

Assisted lift operated 2/2-way solenoid valves Type EV251B

INTRODUCTION GRP ONE PIECE STORAGE TANKS

GMS-015Y. Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3

MC200CAB/4 Integral Version

Variable Speed Product Line

HDS 5/11 U. Fine-mesh water filter. Efficiently protects high-pressure pump against contamination. Easy to remove from outside.

Each pump shall be equipped with carbon/graphite vanes. A vacuum relief valve shall be incorporated into the design of the pump.

ECONOMISER SERIES E2T USER MANUAL

Urinal Flushing. Hydraulic Valve Infrared Control (IRC) Valve Direct Flush

TECHNICAL INFORMATION

HIB Enclosed Inverter User Guide

JCB DIESEL GENERATOR TECHNICAL SPECIFICATIONS

KVAR POWERHOUSE RANGE 140 KVA 200 KVA

Energetech LLC 7427 S. Main (P.O. Box 400) Midvale, Utah (801) Ph. (801) Fx.

MF4E MF4E

MGE TM Galaxy TM 7000

ATyS d M Remotely operated Transfer Switching Equipment from 40 to 160 A

GRUNDFOS DATA BOOKLET. Hydro Multi-B. Booster systems with 2 or 3 pumps. 50/60 Hz

SPECIFICATIONS SEWAGE/SUMP DUPLEX SYSTEM ZOELLER COMPANY SUBMERSIBLE SEWAGE OR DEWATERING PUMPS

DX 3 MCBs. Choice of DX 3 MCBs for capacitor banks. Technical data

WC FLUsHiNG. WC Flushvalves offer an average of 30% water saving...

Insertion magnetic inductive flowmeter

SLH 1202 to Air-to-Water Reverse Cycle Heat Pumps. With Screw Compressors. 261 to 775 kw. 287 to 853 kw

Backflushing Filter AutoFilt RF3

Inst all a ti o n and Oper a tin g Instru c ti o n s

825-P Modular Protection System for motors Specification Guide

Chiller. SWS/SWR 1602 to Water Cooled Chillers Cooling Only and Condenserless Versions Engineering Data Manual.

10 mm free passage. Submersible drainage pumps US Application. Safe to run dry. Easy to maintain with guide rail system. 10 mm free passage

Paddle-wheel flow controller for On/Off control

Company name: GSI Created by: Xiao Ying Wong Phone: Date: 10/03/2017 Client: Client Number: Contact:

@Perkins. Technical Data Series TAG1A TAG2A TAG3A. Diesel Engine - Electropak. Basic technical data

Fans Air Handling Units Air Distribution Products Fire Safety Air Curtains and Heating Products Water terminals SYSCOIL. Centrifugal fan coil units

Emergency lighting units EM series

1 Phase electronic contactor (SC 1)

User Manual. Digital Energy Uninterruptible Power Supply ML Series UPS VA. GE Digital Energy Power Quality. GE imagination at work

Java Basin Mixer Range

Features: Concealed installation. Compact design. Available in electric, LPHW or ambient.

REVISION HISTORY REVISION HISTORY

Transcription:

Boost-A-Break - Break Tank & Booster Sets BTAB Fixed and Variable Speeds Overview Datasheet Page 1 of 9 Overview Break Tank assembly with Fluid Category 5 protection by virtue of the integral Type AB air gap. The unit is supplied as a complete package on a stainless base ready for installation. The primary purpose is to provide backflow protection in accordance with the latest Water Regulations. The BTAB unit also boosts the water pressure for elevated areas or where a high flow rate is required e.g. wash-down. The cistern has a screened overflow and weir, making it suitable for unorthodox applications, which require a Hygienic Type AB air gap e.g. butchery and vegetable preparation. The unit is quiet by virtue of a centrifugal pump, anti-vibration rubber feet and flexible stainless braided connection hoses. There is a range of fixed and variable speed (inverter) pumps. The variable speed range has the compactness of the fixed speed range plus additional benefits see page 3. For higher flow rates and variable speed pumps see page 3. For domestic boosting use Pent-A-Boost model BTAF. Applications The following are Fluid Category 5 examples see Water Regulations (Table 6.1e) - Waste bin washing Hose union taps non-domestic Wash-down animals or any Fluid Category 5 Underground or surface irrigation see HUBG Laboratories Baths in health care premises Showers health care see Care Shower Sinks with hoses Bidets Bedpan washing Vegetable washing Butchery & meat equipment / Slaughterhouse Clothes washing machines healthcare premises Dish washing machines healthcare premises Applications deemed to be Category 5 by water company Water Regulations The assembly is fully Water Regulations approved & complies with the requirements of the Water Regulations when installed and used correctly. A Break Tank with a Type AB air gap provides protection against Fluid Category 5 risks - these risks are the highest level. Boost-A-Break can therefore be used for all applications requiring backflow protection use Pent-A-Boost for drinking water. The Regulations require point of use protection. For example, it is not permissible to use the same Break Tank to serve a bedpan washer (Fluid Category 5) and a dishwasher. However several appliances of the same type can be served from the same Break Tank unit e.g. irrigation network. Specification Supply min. 1.0 bar min. maintained (dynamic) Supply max. 10 bar Outlet See flow graph page 2 Gauge 63 dia. glycerine filled (except dual) Capacity 24 Lt Cistern Capacity 24 Lt Inlet See Inlet Control table Outlet See Outlet Control table Temperature 30 o max. ambient Water Regulations Approval 1501308 Materials Base / drip tray / fasteners Stainless steel 304 Pump (wetted parts) Stainless steel 304 Pipes / fittings Copper / Brass / Stainless Cistern 24 Lt MDPE reserve the right to change specifications, 1200 Fixed speed. Stainless screened slot, drip tray, base, and hoses. Only 675 mm high 3-7 Variable speed. Surge free, quiet and economical. Height 775 mm. Flow output up to 1.2 Lt/s 3-10A Dual Pump Duty Assist. Pumps alternate daily to prevent stagnation. Flow output up to 2.4 Lt/s Optional Wall Brackets. Stainless steel tray With galvanised brackets code BTBRA. Second set can be located underneath on floor Registered UK Design 4036013 Registered UK Design 4036010 Registered UK Design 4036012

Boost-A-Break Break Tank & Booster Set BTAB Fixed Speed 700, 900, 1200, 4-2, 4-3, 4-4 - Datasheet Page 2 of 9 Description Fixed Speed There is a choice of six pump duties see chart. The units are compact and the pump operation is automatically controlled. The initial cost of fixed speed pumps is less than the equivalent variable speed but fixed speed pumps generally consume more energy over a lifetime. For low use applications or where the demand is high and near constant, a fixed speed pump is adequate. The pumps are self priming. The relatively large 24 litre pressure vessel allows about 5 litres of water to be supplied before the pump switches on. Inlet Control Fast and accurate level control is achieved with a solenoid valve. Electrodes provide on/off full flow control with 60 mm delayed action. The DN20 inlet is equivalent to ten ½ BS1212 HP float valves. is fitted as standard to high flow models - see table below and optional on others e.g. for low pressure supplies. Providing the following minimum dynamic supply pressure is maintained at the inlet, the cistern will not run dry even with an open outlet. Electrical Specification Motor 2 Pole 50 Hz IP54, 230 V (1ph) or 400 V (3ph) star 1 phase 3 phase Input max A (Run) A (Start) A (Run) kw 700 3.0 9.8 1.4 0.65 900 4.2 13.8 1.6 0.90 1200 5.4 18.0 2.0 1.20 4-2 3.0 9.8 1.4 0.65 4-3 4.2 13.8 1.6 0.90 4-4 5.4 18.0 2.0 1.20 Class Run-on Timer BMS Low level cut out Connection Class 1 (requires earth wire) 180 sec Volt free SPDT for low level alarm Stops pump via electrodes in tank (Warning lamp on control box) auto reset once tank refilled M20 hole in control box IP65 (Enclosure) / IP54 (Pump) Inlet Minimum Dynamic Pipe Velocity m/s 700, 900 DN20 female union 1.0 bar 3.7 1200, 4-2, 4-3, 4-4 female union 1.0 bar 2.8 Outlet Control The pressure switch is factory set according to the table below. To stabilise the outlet pressure, a factory fitted Regulating Valve (PRV) is optional code BTPRV. Or use a variable speed pump see page 3. The outlet flow is automatically limited to 1.17 Lt/s or 1.5 Lt/s for the 4- series. Outlet Switch on (min.) Outlet with Optional PRV 1 Max 2. 3 700 DN20 2.0 bar 2.0 bar 3.3 bar 1.8 bar 900 DN20 3.0 bar 3.0 bar 4.5 bar 2.8 bar 1200 DN20 4.0 bar 3.0 bar 5.7 bar 3.8 bar 4-2 DN20 1.0 bar 1.0 bar 2.3 bar 0.8 bar 4-3 DN20 2.0 bar 2.0 bar 3.4 bar 1.8 bar 4-4 DN20 3.0 bar 3.0 bar 4.5 bar 2.8 bar Notes - 1. Adjustable. 2. Without PRV 3. air pressure with zero water pressure. Registered UK Design 4036013 BTAB 700, 900 &1200 Kg Dry Kg Gross Base Width Base Depth 28-36 68-74 400 500 Flexible stainless braided hoses are supplied for the inlet and outlet. These have a female swivel nut (union) and a fibre washer. See Inlet Control and Outlet Control tables for size. A full bore inlet servicing valve as required by the Regulations (G16.4) - is fitted upstream of the solenoid filling valve. The Overflow is 40 mm plastic with compression nut. Codes and Descriptions Fixed Speed Inlet Code Description DN20 BTAB700 Boost-A-Break AB Gap 700 Fixed 230 V 2.0 bar DN20 BTAB900 Boost-A-Break AB Gap 900 Fixed 230 V 3.0 bar BTAB1200 Boost-A-Break AB Gap 1200 Fixed 230 V 4.0 bar BTAB4-2 Boost-A-Break AB Gap 4-2 Fixed 230 V 1.0 bar BTAB4-3 Boost-A-Break AB Gap 4-3 Fixed 230 V 2.0 bar BTAB4-4 Boost-A-Break AB Gap 4-4 Fixed 230 V 3.0 bar Note - model 900 often used for wash-down reserve the right to change specifications,

Boost-A-Break Break Tank & Booster Set BTAB Variable Speed 1.0 Lt/s - Datasheet Page 3 of 9 Description Variable Speed (1.0 Lt/s) Variable speed pumps provide only the pressure required to meet demand making the unit economical and extending the life of the pump. There is a choice of 9 variable speed pumps with a 1.0 Lt/s output see chart below. The variable speed range has all the benefits of the fixed speed pumps plus - Higher flow rate up to 2.0 Lt/s output (3.7 Lt/s Dual) Variable speed speed changes to meet demand Quiet especially at low demand Surge free inverter pump avoids high current demand Constant supply pressure Electronically controlled automatic pump venting system Inlet Control Fast and accurate level control is achieved with solenoid valve(s). Level electrodes provide on/off full flow control with 60 mm delayed action. Inlet Minimum Dynamic Pipe Velocity m/s 3-5, 3-7 DN20 female union 1.0 bar 3.7 3-10, 1-5, 1-6, 1-7, 1-8, 1-9, 1-10 female union 1.0 bar 2.8 Outlet Control The outlet pressure is controlled by a transducer, which is factory set to the default set point in the table below and controlled to within a 10% band. The outlet pressure is therefore constant up to the maximum duty of the pump. Outlet Set point Switch on (min.) 1 Switch off (Max) 1 Max 2 3 3-5 DN20 2.0 bar 1.8 bar 2.2 bar 2.8 bar 1.4 bar 3-7 DN20 3.0 bar 2.7 bar 3.3 bar 4.6 bar 2.1 bar 3-10 4.0 bar 3.6 bar 4.4 bar 5.5 bar 2.8 bar 1-5 5.0 bar 4.5 bar 5.5 bar 7.0 bar 3.5 bar 1-6 6.0 bar 5.4 bar 6.6 bar 7.0 bar 4.2 bar 1-7 7.0 bar 6.3 bar 7.7 bar 11.7 bar 4.9 bar 1-8 8.0 bar 7.2 bar 8.8 bar 11.7 bar 5.6 bar 1-9 9.0 bar 8.1 bar 9.9 bar 11.7 bar 6.3 bar 1-10 10.0 bar 9.0 bar 11.0 bar 11.7 bar 7.0 bar Notes - 1. Differential +/- 10% of set point. 2. If set to full speed. 3. air pressure with zero water pressure, 0.7 X set point. The graph below illustrates the benefit of variable speed pumps. The outlet pressure is constant despite varying flow demand. Illustrated using default set point. The set point can be altered at the factory. On-site alterations require a commissioning service. BTAB3-7 Electrical Specification Motor 2-Pole 50 Hz 230 V 1 ph (3-5, 3-7, 3-10, 1-5) 400 V 3 ph (1-6, 1-7, 1-8, 1-9, 1-10) 1 phase 3 phase Input max A (Run) A (Run) kw 3-5 4.2 0.55 3-7 5.5 0.75 3-10 7.5 1.10 1-5 5.0 1.10 1-6 3.7 2.20 1-7, 1-8, 1-9, 1-10 5.0 3.00 Class Class 1 (requires earth wire) BMS Volt free SPDT relay general fault - pump / inverter / low level alarm Low level cut out Stops pump via electrodes in tank (Warning lamp on control box) auto reset once tank refilled IP65 (Enclosure) / IP55 (Pump) Connection 1 phase M20 1 phase + neutral + earth 3 phase 1 M20 3 phases + neutral + earth Note 1. The control circuit is 230 V so a neutral supply is required Flexible stainless braided hoses are supplied for the inlet and outlet. These have a female swivel nut (union) and a fibre washer. See Inlet Control and Outlet Control tables for size. A full bore inlet servicing valve as required by the Regulations (G16.4) - is fitted upstream of the solenoid filling valve. The Overflow is 40 mm plastic with compression nut. Codes and Descriptions Variable Speed (1.0 Lt/s) Inlet Code Description DN20 BTAB3-5 Boost-A-Break AB Gap 3-5 Variable 230 V 2.0 bar DN20 BTAB3-7 Boost-A-Break AB Gap 3-7 Variable 230 V 3.0 bar BTAB3-10 Boost-A-Break AB Gap 3-10 Variable 230 V 4.0 bar BTAB1-5 Boost-A-Break AB Gap 1-5 Variable 230 V 5.0 bar BTAB1-6 Boost-A-Break AB Gap 1-6 Variable 400 V 6.0 bar BTAB1-7 Boost-A-Break AB Gap 1-7 Variable 400 V 7.0 bar BTAB1-8 Boost-A-Break AB Gap 1-8 Variable 400 V 8.0 bar BTAB1-9 Boost-A-Break AB Gap 1-9 Variable 400 V 9.0 bar BTAB1-10 Boost-A-Break AB Gap 1-10 Variable 400 V 10.0 bar reserve the right to change specifications,

Boost-A-Break Break Tank & Booster Set BTAB Variable Speed 2.0 Lt/s - Datasheet Page 4 of 9 Description Variable Speed (2.0 Lt/s) There is a choice of 7 variable speed pumps with a 2.0 Lt/s output see chart below. The higher flow units are suitable for supplying multiple outlets or applications where a greater flow rate is required. Inlet Control Fast and accurate level control is achieved with two 1 filling solenoid valves (except model 5-4 which has a single solenoid). Level electrodes provide on/off full flow control with 60 mm delayed action. Inlet Minimum Dynamic Pipe Velocity m/s 5-4 female union 1.0 bar 2.8 5-8, 5-10, 2-5, 5-16, 2-7, 2-8 female union 1.0 bar 2.4 Outlet Control The outlet pressure is controlled by a transducer, which is factory set to the default set point in the table below and controlled to within a 10% band. The outlet pressure is therefore constant up to the maximum duty of the pump. Electrical Specification Motor 2-Pole 50 Hz 230 V 1 ph (5-4, 5-8) 400 V 3 ph (5-10, 2-5, 5-16, 2-7, 2-8) 1 phase 3 phase Input max A (Run) A (Run) kw 5-4 7.5 1.10 5-8 7.5 1.50 5-10, 2-5 3.7 2.20 5-16, 2-7, 2-8 5.0 3.00 Class Class 1 (requires earth wire) BMS Volt free SPDT relay general fault - pump / inverter / low level alarm Low level cut out Stops pump via electrodes in tank (Warning lamp on control box) auto reset once tank refilled IP65 (Enclosure) / IP55 (Pump) Connection 1 phase M20 1 phase + neutral + earth 3 phase 1 M20 3 phases + neutral + earth Note 1. The control circuit is 230 V so a neutral supply is required Outlet Set point Switch on (min.) 1 Switch off (Max) 1 Max 2 3 5-4 1.5 bar 1.4 bar 1.7 bar 2.8 bar 1.1 bar 5-8 3.0 bar 2.7 bar 3.3 bar 5.0 bar 2.1 bar 5-10 4.0 bar 3.6 bar 4.4 bar 7.0 bar 2.8 bar 2-5 5.0 bar 4.5 bar 5.5 bar 7.0 bar 3.5 bar 5-16 6.0 bar 5.4 bar 6.6 bar 11.7 bar 4.2 bar 2-7 7.0 bar 6.3 bar 7.7 bar 11.7 bar 4.9 bar 2-8 8.0 bar 7.2 bar 8.8 bar 11.7 bar 5.6 bar Notes - 1. Differential +/- 10% of set point. 2. If set to full speed. 3. air pressure with zero water pressure, 0.7 X set point. The graph below illustrates the benefit of variable speed pumps. The outlet pressure is constant despite varying flow demand. Illustrated using default set point. The set point can be altered at the factory. On-site alterations require a commissioning service. Registered UK Design 4036010 BTAB5-8 Shown ( apply to all Variable Speed units) Kg Dry Kg Gross Base Width Base Depth 46-85 86-125 400 500 Flexible stainless braided hoses are supplied for the inlet and outlet. These have a female swivel nut (union) and a fibre washer. See Inlet Control and Outlet Control tables for size. A full bore inlet servicing valve as required by the Regulations (G16.4) - is fitted upstream of the solenoid filling valve. The Overflow is 40 mm plastic with compression nut. Codes and Descriptions Variable Speed (2.0 Lt/s) Inlet Code Description BTAB5-4 Boost-A-Break AB Gap 5-4 Variable 230 V 1.5 bar BTAB5-8 Boost-A-Break AB Gap 5-8 Variable 230 V 3.0 bar BTAB5-10 Boost-A-Break AB Gap 5-10 Variable 400 V 4.0 bar BTAB2-5 Boost-A-Break AB Gap 2-5 Variable 400 V 5.0 bar BTAB5-16 Boost-A-Break AB Gap 5-16 Variable 400 V 6.0 bar BTAB2-7 Boost-A-Break AB Gap 2-7 Variable 400 V 7.0 bar BTAB2-8 Boost-A-Break AB Gap 2-8 Variable 400 V 8.0 bar reserve the right to change specifications,

Boost-A-Break Type equation Break here.tank & Booster Set BTAB Dual Pump - Duty Standby Datasheet Page 5 of 9 Description Dual Pump Dual pump sets are available as Duty Standby or Duty Assist. Both pumps are variable speed and set to provide constant pressure. Remarkably, the foot print is the same as the single pump set yet the duty is up to 2.4 Lt/s. The parallel mounted pumps draw water from the integral ultra-fast filling tank. 3-7S Dual Pump Duty Standby Flexible stainless braided hoses are supplied for the inlet and outlet. These have a female swivel nut (union) and a fibre washer. See Codes and Descriptions and Outlet Control tables for size. A full bore inlet servicing valve as required by the Regulations (G16.4) - is fitted upstream of the solenoid filling valve. The Overflow is 40 mm plastic with compression nut. Electrical Specification Class BMS Low level cut out Connection 1 phase Class 1 (requires earth wire) Volt free SPDT relay general faultpump / inverter / low level alarm Volt free SPDT for low level alarm Stops pump via electrodes in tank (Warning lamp on control box) auto reset once tank refilled IP65 (Enclosure) / IP55 (Pump) M20 1 phase + neutral + earth Duty Standby Only one pump runs at any one time. The pumps alternate on a daily basis to avoid stagnation and ensure even use. A manual override switch hand allows either pump to be isolated and run only the healthy pump. Motor Voltage 230 V 1 phase MCB in control box for each pump motors thermal protection (IEC 34-11: TP 211) 3-7S 3-10S 1-5S 5-4S 5-8S 1 phase A (Run) 5.5 7.5 5.0 7.5 7.5 Input max kw 0.75 1.10 1.10 1.10 1.50 Outlet Control Outlet 3-7S 3-10S 1-5S 5-4S 5-8S Notes - DN20 Set point 3.0 bar 4.0 bar 5.0 bar 1.5 bar 3.0 bar Switch on Switch off 1 1 (min.) (Max) 2.7 bar 3.3 bar 3.6 bar 4.4 bar 4.5 bar 5.5 bar 1.4 bar 1.7 bar 2.7 bar 3.3 bar 2 Max 4.6 bar 5.5 bar 7.0 bar 2.8 bar 5.0 bar 3 2.1 bar 2.8 bar 3.5 bar 1.1 bar 2.1 bar Registered UK Design 4036011 1. Differential +/- 10% of set point. 2. If set to full speed. 3. air pressure with zero water pressure, 0.7 X set point. BTAB5-8 Duty Standby Shown Codes and Descriptions Duty Standby Inlet Code Description DN20 BTAB3-7S Boost-A-Break 3-7 Duty Standby Vari 230 V 3.0 bar BTAB3-10S Boost-A-Break 3-10 Duty Standby Vari 230 V 4.0 bar BTAB1-5S Boost-A-Break 1-5 Duty Standby Vari 230 V 5.0 bar BTAB5-4S Boost-A-Break 5-4 Duty Standby Vari 230 V 1.5 bar BTAB5-8S Boost-A-Break 5-8 Duty Standby Vari 230 V 3.0 bar Tel: 01442 823123 Fax: 01442 823234 reserve the right to change specifications,

Boost-A-Break Break Tank & Booster Set BTAB Dual Pump - Duty Assist Datasheet Page 6 of 9 Duty Assist Allows the second pump to automatically switch on when required, thus doubling the output. Alternate starting avoids stagnation and ensures even use. If one pump develops a fault, the controller isolates and continues with the healthy pump (the BMS fault relay activates together with panel lamps). Normal demand is often met with only one small pump running at optimum efficiency, offering substantial energy saving compared to one larger pump. Furthermore smaller pumps are quieter. Outlet 3-5A 3-7A 3-10A Notes - Set point 2.0 bar 3.0 bar 4.0 bar Switch on Switch off 1 1 (min.) (Max) 1.8 bar 2.2 bar 2.7 bar 3.3 bar 3.6 bar 4.4 bar 2 Max 2.8 bar 4.6 bar 5.5 bar 3 1.4 bar 2.1 bar 2.8 bar 1. Differential +/- 10% of set point. 2. If set to full speed. 3. air pressure with zero water pressure, 0.7 X set point. Information display messages include Healthy Pump-1 running Pump-2 running Last started Last stopped Set point pressure Fault display messages include Pump-1 fault Pump-2 fault Pump-1 disabled Pump-2 disabled Low-level fault High-level fault Four examples of typical messages - Specification & Materials See page 1 and 4 Motor Voltage 230 V 1 phase MCB in control box for each pump motors thermal protection (IEC 34-11: TP 211) 3-5A 3-7A 3-10A 1 phase A (Run) 8.4 11.0 15.0 Option to disable Pump-2 Healthy system and set point pressure Low level fault Date when the pump last started Input max kw 1.10 1.50 2.20 Digital Controller The controller includes a digital display with setting buttons and button lock to prevent tampering. Both pumps can be tested and disabled if necessary via the display. Controller features include pump changeover every 24 hours if continuous draw off causes one pump to run and pump pulse every 24 hours to avoid seizure. The user can also view the set pressure and when the pump was last started and stopped via the display. Purge The digital controller also features an automatic vessel purge facility for Legionella control. Every 24 hours the switch-on pressure is dropped below the vessel pre charge pressure, ensuring the entire contents of the vessel is emptied. Registered UK Design 4036012 BTAB3-10 Duty Assist Shown ( apply to all Duty Assist Units) Codes and Descriptions Duty Assist Inlet Code Description BTAB3-5A Boost-A-Break 3-5 Duty Assist Vari 230 V 2.0 bar BTAB3-7A Boost-A-Break 3-7 Duty Assist Vari 230 V 3.0 bar BTAB3-10A Boost-A-Break 3-10 Duty Assist Vari 230 V 4.0 bar Tel: 01442 823123 Fax: 01442 823234 reserve the right to change specifications,

Boost-A-Break Break Tank & Booster Set BTAB Dual Pump 5-8 Duty Assist Datasheet Page 7 of 9 5-8 Duty Assist Remarkably high duty (up to 3.7 Lt/s) for the foot print of the unit, ideal for installing in locations where floor space is at a premium. The skid mounted base occupies less than 0.5m² of floor space and allows the unit to be easily and securely transported. The integral 100 litre GRP break tank is rapidly filled by a triple solenoid valve arrangement. 5-8A includes all of the benefits of other Variable Speed Duty Assist units see pages 4 and 5. DN40 flexible stainless braided hoses are supplied for the inlet and outlet. These have a female swivel nut (union) and a fibre washer. The DN40 inlet connection is reversible, allowing for left or right hand side configurations. A full bore inlet servicing valve as required by the Regulations (G16.4) - is fitted upstream of each of the three solenoid filling valves. The Overflow is 50 mm plastic with compression nut. Motor Voltage 230 V 1 phase MCB in control box for each pump motors thermal protection (IEC 34-11: TP 211) 1 phase Input max A (Run) kw 5-8A 15.0 3.00 Inlet Control Fast and accurate level control is achieved with three solenoid valves. Level electrodes provide on/off full flow control with 60 mm delayed action. Screened Weir Overflow in the rear of the Cistern provides Type AB Gap Outlet Control The outlet pressure is controlled by a transducer, which is factory set to 3 bar (the default set point ) and controlled to within a 10% band see table below. The outlet pressure is therefore constant up to the maximum duty of the pumps. The set point can be altered at the factory, on-site alterations require a commissioning service. Outlet Set point Switch on (min.) 1 Switch off (Max) 1 Max 2 3 5-8A DN40 3.0 bar 2.7 bar 3.3 bar 5.0 bar 2.1 bar Notes - 1. Differential +/- 10% of set point. 2. If set to full speed. 3. air pressure with zero water pressure, 0.7 X set point. Registered UK Design 4036009 Codes and Descriptions Inlet Code Description DN40 BTAB5-8A Boost-A-Break 5-8 Duty Assist Vari 230 V 3.0 bar reserve the right to change specifications,

Boost-A-Break - Break Tank & Booster Set BTAB Options Datasheet Page 8 of 9 Options GRP Wall Cover High level alarm relay (volt free) - recommended to minimise the risk of water damage. Regulating Valve (PRV) constant outlet pressure factory fitted fixed speed only Wall Brackets suitable for units up to 5-10 GRP Drip Trays all fixed speed and up to 3-7S GRP Wall Covers use wall brackets e.g. bin store GRP Enclosures for exterior use 3 phase pumps standard on 5-10, 2-5, 5-16, 2-7, 2-8 Pulse timer prevents pump sticking if infrequently used all except dual (already included). Duty Standby Controls for use with two single pump BTAB units where a loss of the water supply would be critical e.g. hospitals Suitability Up to 5-10 single All except dual All DN20 All fixed speed Up to 3-7S Up to 3-7S All fixed speed All fixed speed Up to 3-10A Up to 5-4 Single Up to 5-10 Single 5-8A All except BTCAB1 Fixed Speed Variable Speed 2 x Single pump variable speed Code BTBRA BTPT BT20-25 BT2-3 BTDT1 BTDT2 EVUP100V BTPRV BTCAB1 BTCAB2 BTCAB3 BTDUALCAB BTFPS BTBMS1 BTBMS2 ELCBTPCO Description Wall Bracket for Break Tanks AV Mounts Pulse Timer - Infrequent Use/Anti Seize Upgrade from DN20 to Solenoid Upgrade to 3 phase pump GRP Drip Tray c/w Float Switch (up to 3-7S) Controller & Additional Sol for Drip Tray Exp. 10 bar Ø450X910 High Vert PRV for Fixed Speed Break Tank Enc. 1150x1150x1050 GRP c/w Heating Enc. 660x600x780 GRP c/w Frost BT Wall Cover 1035hx735Wx610D Enc. 1150x1150x2100 GRP c/w Heating BTCAB3 Insulated GRP Wall Cover, for use with the BTBRA Wall Mounting Brackets. The GRP colour is BS 00-A-05 (RAL equivalent is 7038). Integrated Frost System (BTFPS see BTCAB2 section below) can be added to the Wall Cover. Not suitable for dual pump units or single pump larger than 5-10. BT Frost System BT High alarm BMS Fixed speed pumps BT High alarm BMS Variable speed pumps Duty Standby Controls Electrical control box twin pump changeover Wall Brackets BTBRA - Galvanised Steel Wall Mounting Brackets with Anti Vibration mounts. For use with single pump Boost-A-Break units, up to model BTAB5-10. Not suitable for dual pump units. GRP Enclosures BTCAB2 Lift Off GRP Enclosure for exterior use, supplied with a Padlock and Integrated Frost System. A thermostat attached to the control box will cause the pump to run against a closed head to generate heat. The colour of the enclosure is RAL 6005, it is not suitable for dual pump units or single pumps larger than the BTAB5-4. Tel: 01442 823123 Fax: 01442 823234 reserve the right to change specifications,

Boost-A-Break - Break Tank & Booster Set BTAB Options (Continued) Datasheet Page 9 of 9 BTCAB2 BTDUALCAB GRP Heated Enclosure with Kiosk Door, for external use with the BTAB5-8A. Taller version of the BTCAB1 with integrated bar heater, complete with thermostat. BTCAB1 GRP Heated Enclosure with Kiosk Door, for external use of all Boost-A-Break units (except for the BTAB5-8A). The housing has an integrated bar heater, complete with thermostat. The exterior colour of the enclosure is RAL6005. GRP Drip Tray BTDT1 GRP Drip Tray for use with Boost-A-Break units (up to the BTAB3-7S), where it is impractical to fit an overflow. BTDT2 Additional isolating solenoid. The whole pump set sits on top so any water leaking from the tank or pump is captured in the moat and runs into the well, activating the float switch and isolating the water supply, which stops the pump. The pump restarts pump once water is drained from the well. reserve the right to change specifications,