Coil Data Nominal Current MA Nominal VA Sealed Single Pole Normally Open (SPNO) White Rodgers Q

Similar documents
Coil Data Nominal Current MA Nominal VA Sealed. Coil Data Nominal Current MA Nominal VA Sealed. Single Pole Double Throw (SPDT)

TOTALINE CAPACITORS RUN CAPACITORS OVAL MOTOR RUN CAPACITORS DUAL SINGLE

Table of Contents. HCC Contactor Nomenclature

JARD by MARS JARD by MARS

XMC0 Series DEFINITE PURPOSE CONTACTORS

PCB Relay. Ordering Information. Compact, Low-cost 30-A Power Relay for PC Board or Panel-mounted Applications G8P - - VDC

PCB Relay. Ordering Information. Compact, Low-cost 30-A Power Relay for PC Board or Panel-mounted Applications G8P - - VDC

AC Leak Freeze AIR CONDITIONING. AC Leak Freeze permanently seals leaks in air conditioning and refrigeration systems

Function Relays, Interfaces and Converters

M-SERIES MAGNITUDE LIGHTING MAGNETIC DIMMABLE CLASS 2 LED DRIVER QUICK SPECS ENCLOSURE DETAILS

48 Series - Contactor Relay 4PST - N.O. - Double Make, 15 Amp

5 Series - Mechanical Latch 2PDT - 4PST, 30 Amps

AC 250V AC 250V AC 250V AC 250V DC 110V DC 110V DC 110V DC 110V Max. Allowable Current 15A 10A 10A 10A

XMC0 Series. Definite Purpose Contactors

PCB Relay. New G8P. Ordering Information. Compact, Low-cost 30-A Power Relay for PC Board or Panel-mounted Applications G8P - - VDC

Types of Motor Starters There are several types of motor starters. However, the two most basic types of these electrical devices are:

Type FEC Epoxy Encapsulated, Copper-Wound Industrial Control Transformers

ICT TRANSFORMERS. Industrial Control Transformers provide a low and safe control voltage for the operation of many electromagnetic devices

Industrial Control Transformers

60T Series Snap-Action Temperature Controls

Bussmann series Quik-Spec Power Module Switch elevator disconnect

PCB Relay. Ordering Information. SPST-NO Type Breaks 10-A Loads; SPST-NO + SPST-NC Type Breaks 8-A Load G6C - - VDC

Ordering Information. Text PCB Power Relay G5RL. Low-profile Relay with Various Models. Power Relays

58T Series. Adjustable Temperature Controls. Adjustable Temperature Controls

Solid-State Relays. Solid-State Relays. Features. Description. Overview

R1000 Series Relays. Features and Benefits. Enclosed Relay Contacts Delivers maximum durability and extends life; inhibits corrosion and dust build-up

Solid-State Relays. Solid-State Relays. Features. Description. Overview

C E R T I F I C A T E O F C O M P L I A N C E

System 350 P352AB Electronic Pressure Control Series

A25 Series Warm Air Control with Manual Reset

AC Relays. Type IC5182. Ordering Information. Control Power Requirements. Contact Ratings (Amperes)

Power PCB Relay. Type Contact material Contact form Construction Part number General purpose AgCdO SPDT Semi-sealed G2R-1

How to Select the RE Industrial Actuator Part Number

Features. Type List A

60T Series Snap-Action Temperature Controls

Magnetic Overload Relays

C E R T I F I C A T E O F C O M P L I A N C E

1. The term "withstand" means "the unit will remain in place without separation of any parts from the device when subjected to the seismic forces.

Features. Type List 832A

The Z Series. SCR Power controllers for resistance heating applications. Zero-Fired SCR Power Controllers AMPS VAC

Comfort. Description. Applications

SECTION MOTOR CONTROL

R820 REV2 SERIES SCR POWER CONTROLS NOVEMBER 2017

Frequency 10 to 55 Hz, Amplitude 0.75mm Frequency 10 to 55 Hz, Amplitude 0.75mm. Frequency 10 to 55 Hz, Amplitude 0.75mm

TA Ta VA CTRL-XFRMR

A. Products shall be designed, manufactured, tested, and installed in compliance with the following standards:

B115...B180 RF200 RFN200 B250...B400 RF400 RFN400

SERIES SINGLE AND DOUBLE-POLE ROCKER SWITCHES

GUIDE SPECIFICATIONS CE Series Two Stage R-410A

Selection Guide Motor Control Device Solutions

30C30 definite purpose contactor

PCB Relay. Contact form Terminals Coil terminals Rated voltage Model SPST-NO #250 tab terminals PCB terminals 5, 12, 24 VDC G4A-1A

Enclosed Full-Voltage Starters

WARREN COUNTY, N.Y. M/E REFERENCE A. Submit manufacturer's product data on all motors and adjustable speed drives.

Power Supply. & Door Controllers 238 SECURITY DOOR CONTROLS

contactor may be required to interrupt up to 200% current. The N.O. contacts are equipped with permanent magnet blowouts to meet this requirement.

Enclosed Full-Voltage Starters

Model Number Structure

HVAC Drives Lenze AC Tech MCH Series Price Book May US Dollars

3. Coils shall be of molded construction

Comfort. Sewage Treatment Plants. Petrochemical Facilities, Oil Rigs. Unattended Pumping Stations. Chemical Storage and Handling Facilities

GE Industrial Systems. General Purpose Plug-in Relays. Catalog

MAGNETIC MOTOR STARTERS

Meta Solution. Contactors and Overload relays

Powers TM Controls SW 134 Pressure Electric Switch (Adjustable Differential)

Sealed type washable 1C H-1C-C 812H-1C-V 812H-1C-S (SPDT) F 812H-1C-C F 812H-1C-V F 812H-1C-S F

General Purpose Buck - Boost Wiring Diagrams... 86

Series R19. Power Rocker Switches MARK OPTIONS COLOR OPTIONS TERMINATION OPTIONS HOW TO ORDER

Safety Relay Unit. Ordering Information. Ideal for Safety Door and Emergency Stop Switch Circuits for Machines in European Countries

Industrial Control Power Transformers Class MT

Standard Materials Bodies and covers: copper-free aluminum.

AF40... AF96 3-pole contactors Technical data

BAC Custom Engineered Controls

4. Heavy duty Silver Metal Oxide contacts to provide long electrical endurance.

PULLOUT DISCONNECT SWITCHES

Definite Purpose Contactors Types DP, DPA, and SYD Class 8910

McQuay. Ceiling Concealed Water Source Heat Pump. CCH, CCG, CCW 015, 019 Vintage A. Last Manufactured: 1995

TECHNICAL GUIDE GENERAL HIGH-EFFICIENCY WATER SOURCE HEAT PUMPS AND WATER COOLED AIR CONDITIONERS

DEFROST CONTROLS PARAGON ERC-2 ELECTRONIC REFRIGERATION CONTROL

Electric Furnace KF/KFS Series

D2SW-AQ. Sealed Subminiature Basic Switch Conforming to IP67 (Excluding the terminals on terminal models) Model Number Legend

the Interactive Catalog

Mounting type Contact form PCB terminals Screw terminals Quick-connect terminals

SERIES SINGLE AND DOUBLE-POLE ROCKER SWITCHES

Part # Features & Applications Specifications Cross Reference

Protectors. 35mm DIN rail snap-on mounting. Wide range of accessories

Zone Valves and Parts (Honeywell)

Water to Water Geothermal Heat Pump 3-Phase Models Both 208 & 480

Type Contact form Enclosure ratings Model Standard SPST-NO (Class A) Flux protection G5LA-1A Sealed

Next-Gen MiniCon 1/2 TO 6 HP MULTI-REFRIGERANT AIR COOLED CONDENSING UNITS

JOSLYN CLARK VACUUM CONTACTOR FEATURES

Applied Decentralized Products Water Source Heat Pump / Rev.A HWH024D, HWH030D HWW024D, HWW030D PL

Manual motor protectors Type MS116 Type MS325 Type MS45X Type MS49X

The Premium Quality Fan Coil Units for Horizontal Application Hydronic or Electric Heat

Switches. SERIES FEATURE ACTUATION MAX RATING SEAL RATING MOUNTING CIRCUITRY 115VAC, 28VDC)

the Interactive Catalog

SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS DESCRIPTION FEATURES H2CA300, 360, 480 & THRU 50 NOMINAL TONS

Micro Contactor MA Series

M9208-xxx-x Series Electric Spring Return Actuators

Design Standard. Purpose: Design Standard:

Transcription:

14/03/08 A136 Relay - General Purpose 90-293Q Enclosed fan relays used for switching single or two speed fan motors, solenoids, relays, resistive loads, heating and cooling applications and general purpose switching Compact, totally enclosed design Class B coil insulation 1/4" quick connect termination coils Contact Rating: 125/250 VAC AC (50/60Hz) LRA @ Resistive Amps @ Coil Data Nominal Current MA Nominal VA Sealed Single Pole Normally Open (SPNO) Inrush VA 8 25 16 125 3 4 White Rodgers 90-290Q 120 8 25 16 25 3 4 White Rodgers 90-291Q 0 8 25 16 12.5 3 4 White Rodgers 90-292Q 8 18 8 125 3 4 White Rodgers 90-293Q 120 8 18 8 25 3 4 White Rodgers 90-294Q 0 8 18 8 12.5 3 4 White Rodgers 90-295Q Relay - General Purpose - Heavy Duty Heavy duty enclosed fan relays operate in any position and are ideal for air conditioning, heating, appliances, fan control and general purpose switching Compact, totally enclosed design Class B coil insulation 1/4" quick connect termination coils Contact Rating: 125/250 VAC AC (50/60Hz) 125VAC 90-370 Resistive Amps @ 277VAC Coil Data Nominal Current MA Nominal VA Sealed Inrush VA 12 8 18 125 3 4 White Rodgers 90-370 120 12 8 18 25 3 4 White Rodgers 90-372 0 12 8 18 12.5 3 4 White Rodgers 90-374 Single Pole Double Throw Isolated Contacts (SPNO / SPNC) 12 8 18 125 3 4 White Rodgers 90-380 120 12 8 18 25 3 4 White Rodgers 90-382 0 12 8 18 12.5 3 4 White Rodgers 90-384

14/03/08 A137 Relay - General Purpose - Semi enclosed switching relays suitable for vending machines, appliances, fan controls, heating and air conditioning applications and general purpose switching Power or pilot duty 90-340 Volts FLA LRA Resistive Amps Terminals 1-2-3 Terminals 4-5-6 Power None R8222B1067 12A @ 120VAC 60A @ 120VAC 20.8A @ 120,208,0,277VAC 120 6A @ 208,0,277VAC 35A @ 208,0,277VAC Power None R4222B1082 3A @ 480VAC 18A @ 480VAC 208/0 Power None R4222B1090 Double Pole Double Throw (DPDT) Power Power White Rodgers 90-340 115/120 12A @ 125VAC 60A @ 125VAC 6A @ 250,277VAC 35A @ 250,277VAC 15A @ 277VAC Power Power White Rodgers 90-341 208/0 Power Power White Rodgers 90-342 Power Power R8222D1014 12A @ 120VAC 60A @ 120VAC 20.8A @ 120,208,0,277VAC 120 6A @ 208,0,277VAC 35A @ 208,0,277VAC Power Power R4222D1013 3A @ 480VAC 18A @ 480VAC 208/0 Power Power R4222D1021 12A @ 120VAC 6A @ 208,0,277VAC 3A @ 480VAC 60A @ 120VAC 35A @ 208,0,277VAC 18A @ 480VAC Double Pole Double Throw (DPDT) - Pilot Duty 20.8A @ 120,208,0,277VAC Power Pilot Duty R8222V1003 Add-A-Relay - - Enclosed Base with a bushing, locknuts and position locking plate to mount in standard electric box with 1/2" knock out Has double break silver alloy contacts and is completely enclosed Operates in any position Volts Description 120 Type 129000AR Add-a relay White Rodgers 90-1

03/11/05 A138 Relay - Hydronic - For V thermostat control of line voltage devices Enclosed intermediate switching relay Includes integral transformer Relay Coil Current: 0.35A Control Circuit Volts (50/60Hz) (Vac @ 50/60Hz) 2 or 3 Wire 120 DPDT R182C1051 Relay - Hydronic - Provides intermediate switching of a line voltage device from a low voltage controller Integral transformer provides low voltage power for control circuit Electrical Connections (main) Electrical Rating Primary Voltage Auxiliary Contacts 2 Wire 120V, 50/60Hz - SPST. For switching one line voltage load RA89A1116 2 Wire 0V, 50Hz, 60Hz 50VA @ VAC DPST. For switching two line voltage loads that have a common power source. One pole line voltage, the other pole low or millivoltage RA832A1074 2 Wire 0V, 50Hz, 60Hz 50VA @ VAC DPST. For switching two line voltage loads that have a common power source. One pole line voltage, the other pole low or millivoltage RA832A1082 Relay - Hydronic - relay with V controller provides intermediate switching of line and low voltage devices from a line or low voltage controller and is typically applied in Hydronic heating systems High load switching capability Troubleshooting LED Push to test button Replaceable transformer fuse Relay for use with external VAC or Vdc supply, with line voltage control, or with internal V transformer supply Secondary of transformer protected by replaceable 1A automotive fuse Electrical Connections (main) Electrical Rating Primary Voltage Transformer Primary Rating Transformer Secondary Rating No. 8 captivated wire clamp screw terminals 120VAC, 60Hz SPDT, plus PowerPile rated low voltage SPST relay 120VAC, 60Hz VAC, 12VA max., 9VA available for external load RA889A1001

29/06/18 Relay - Electric Heat - Quiet A139 Electric Heat Deluxe low voltage control system for electric resistance heating equipment such as baseboard, ceiling cable, duct and fan forced heaters For use with 2 wire Vac thermostats Quiet operation with thermostat cycle (4 to 6 cycles per hour for precision room temperature control) Thermally-operated Micro Switch makes and breaks in about 75 seconds to directly switch up to a 6,000 W load Mounts in any direction and includes 1/2" male conduit bushing, 18" line leadwire and 7 1/2" low leadwire Volts Number of Switches 0 1 R841C1029 208/0 1 R841C1169 Relay - Electric Heat - Normally Closed Normally closed relays and contactors for load control systems Close and leave load operating in case of wiring or control problem, or relay malfunction Consume no power while load is powered; require power only to shed load Operate directly from a pilot duty rated relay in the load control system Volts DPST R8229A1021 Relay - Fan Provide general purpose and heavy duty switching for refrigeration and air conditioning equipment, appliances, vending machines and similar applications Molded terminal numbers and circuit diagram on top of relay provide easy identification for wiring and checking system operation Untapped coil assures cooler operation Laminated magnet construction for higher efficiency Base designed for easy replacement and includes quick connect coil terminals Volts SPDT R8225A1017 DPST, N.O. R8225D1003 Relay - Fan For volt AC control of blowers and other line voltage loads on heating, cooling or heating/cooling systems where V or 120V power supply is already available Compact size - 1/2" conduit hub permits mounting to standard junction box or can be mounted to a flat surface Permits control of single or two speed fan motor Voltage Switch Coil Current SPDT 0.28A White Rodgers 8A04-1 120 SPDT 0.28A White Rodgers 8A04A-1

29/06/18 A140 Fan Relay/Transformer Combination Provides low voltage control of line voltage fan motors and auxiliary circuits in heating, cooling or air conditioning systems Transformer powers low voltage control systems and provides overload protection Mounts on standard 4" x 4" junction box Low voltage terminal board provides convenient connections for thermostat & heating and cooling equipment wiring UL Listed, CSA Certified Application Motor Rating @ 120VAC Supply Secondary Voltage Voltage Full Load Locked Rotor Use with F50 electronic air cleaner, humidifier and blower motor. NEMA standard transformer. Includes relay enclosure. 26.5 V @ 40 VA DPDT 12.0A 72A R8239B1043 Single or two speed fan Hydronic applications. Use with SV9600 and other systems requiring 50 VA. Single or two speed fan or for A/C installs 26.5 V @ 40 VA SPDT 12.0A 72A R8285A1048 26.5 V @ 50 VA DPST (one power rated, one pilot duty) V @ 35 VA SPDT 8.0A / 14.0A 48.0A / 84.0A 12.0A 72A R8285D5001 White Rodgers 8A05A-101 R8239 R8285 8A05A-101