DRENOX IT - ISTRUZIONI ORIGINALI IN LINGUA ITALIANA

Similar documents
BIOXDPV 160/6 IT - ISTRUZIONI ORIGINALI IN LINGUA ITALIANA

DRENOX SUBMERSIBLE SUMP PUMPS FOR DRAINING CLEAR WATER. Usage limitations

1/2 HP SUMP PUMP OWNER'S MANUAL

SUBMERSIBLE WATER PUMPS

SUBMERSIBLE WATER PUMP

SUBMERSIBLE WATER PUMP OPERATING & MAINTENANCE INSTRUCTIONS. Model Nos. CSE400A. Part No iss 2

OWNERS MANUAL ECODIVER

PRESSURE BOOSTER 150

SUBMERSIBLE WATER PUMP

Domestic Water Supply Pressure Pumps

Trouble Shooting Guide EWA, 3-phase (D2422)

X Cube Lift. Model: XCU 190 XCU 180 Installation Instructions

Owners Manual: - Pumps

VADA - V75-S PRODUCT OVERVIEW CONSTRUCTION USAGE LIMITATIONS MOTOR WARRANTY

T35 W35. Thermoelectric cooler Instruction Manual 6. Thermoelektrische Kühlbox Bedienungsanleitung 16. Glacière thermoélectrique Notice d emploi 27

Scissor Lift Model : SC60 SC40 Installation Instructions

OPERATION & MAINTENANCE INSTRUCTIONS

SUBMERSIBLE PUMPS HSE RANGE OPERATING & MAINTENANCE INSTRUCTIONS GC0514

77014 / Automatic Users Manual. Carefully read this entire Instruction Manual before using this product

SUBMERSIBLE PUMP HSE RANGE

SUBMERSIBLE PUMP HSE RANGE

c-go 12V/10A 12V/20A Power supply and battery charger Instruction manual

IT GB F D E NL SF P S RUS CZ SI SK HR SCG

SUBMERSIBLE WATER PUMP

PHOTOCAM IV D GB F RUS I H E LV LT S NL CZ EST SK SLO RO GR TR BG

3 FT CORD UL/NEC Models , , , FT CORD w/gfci UL Models , , ,

IP 900 W/KS & IP 900 D/KS

OPERATION & MAINTENANCE INSTRUCTIONS

OWNER S MANUAL SELF-PRIMING PORTABLE UTILITY PUMP

garden PUMP kit 1 Depth A & B must be less than 9m Max Depth C must be less than 9m Max GardenPump Inst 6/11/07 12:52 Page 1

3 FT CORD Models , , , FT CORD W/GFCI Models , , ,

OWNER S MANUAL. Submersible Sump Pumps Models: XQS33 (1/3 HP Sump Pump) XQS50 (1/2 HP Sump Pump) Suzhou Xin Qi Electric Co.,ltd

USER MANUAL FOR 2000 WATTS POWER INVERTER USER S MANUAL--Read before operating this equipment

WheelieSafe. WheelieSafe. User Manual. Motorized Trolley. Distributor:

OWNER S MANUAL SUBMERSIBLE UTILITY PUMP

250W PUDDLE PUMP WITH AUTO SENSOR MODEL NO: PSP105

SLIDE NEW CONTROL BOARD

Bigfoot Sport Quad Ba ery Operated Ride On Instruc on / Assembling Manual

OPERATOR'S MANUAL SUBMERSIBLE PUMP WSP50AA WSP100AA BY: AHM American Honda Motor Co., Inc. All Rights Reserved.

Instrucciones de instalación y funcionamiento Installation and operating instructions

c-go 24V/6A 24V/8A 24V/12A

BATTERY CHARGER BTC-1005A

6L Oil-less Air Compressor 53103

1. GENERAL SAFETY INSTRUCTIONS 2. GENERAL SAFETY RULES GENERAL OBSERVATIONS.

VADA - V60-J PRODUCT OVERVIEW CONSTRUCTION MOTOR USAGE LIMITATIONS WARRANTY

Owner s Manual. I i i i i i i i i i i i i i i i i i i i i i I. SUBMERSIBLE PUMP WSP50 l WSPlOO I I I I I I I I I I I I I I I I I I I I I

AUTOMATE AC MECHANICAL LIMIT TUBULAR MOTOR

SUNC1200 / ITEM #40882 SUBMERSIBLE UTILITY PUMP OPERATIONS MANUAL

& AL RC-SERIES GB HSC 09-W13 Edition 5. T +31 (0) F +31 (0)

SUNC3000 / Item #40885

SUBMERSIBLE PUMP. Model No: HIPPO 2 OPERATING & MAINTENANCE INSTRUCTIONS

Installation & Operating Manual

Dry installed pump type LANDY BTP.

Bigfoot Mini Quad Battery Operated Ride On Instruction / Assembling Manual

cause injury to humans and other physical damage. : Gives information that does not fall in the WARNING or CAUTION categories.

1 ELECTRIC WATER PUMP

StormPro BA Series Sump Pump

Control panel. For 3 three-phase electric pumps with thermal protection and exchanger

Matala. VersiFlow Series. Instruction and Maintenance Manual

15Amp Intelligent Battery Charger Suitable for SLA, Gel, Maintenance Free, AGM, Deep Cycle batteries

Aqua Ultraviolet Sunami Series Pumps 1/3HP, 3/4HP, 3HP, 4HP, 5HP

SMC BATTERY CHARGER USER S MANUAL SMC USER S MANUAL

AUTOMATIC SUBMERSIBLE UTILITY PUMP

Sump Pump. Installation and Operating Instructions

Submersible Pump Instructions. Safety Instructions

Design Features: User Manual. 1. PFC function. 2. LCD remote control. 3. Battery temperature sensor function.

ELECTRIC LIFTING HOIST

POND PUMP Model Nos:SPP3 & SPP6 0200

GENESIS Electronic Brake Controller Hayes Brake Controller Company - P/N 81790

MODELS 108 and 138 CRAWL SPACE PUMPING SYSTEM PREINSTALLATION CHECKLIST

Wilo-Control SC-Fire Jockey

Table of Contents. General Safety Preparation for Installation Parts List Optional Accessories Part List... 5

HOME CHARGER MODE 2. Series to /32A single phase CONTENTS. Manual IMPORTANT SAFETY INSTRUCTIONS 3 SAFETY INFORMATION 4 INSTALLATION 5

TURBO 40 TURBO 80 TURBO 120 TURBO 160

IMPORTANT SAFETY INSTRUCTIONS

No: Revision Operation & maintenance manual. BRAVO SLURRY PUMPS

Smart 110 with built-in flashlight for 6 240Ah lead-acid batteries

Table 6-1. Problems and solutions with pump operations. No Fluid Delivery

GeyserMax-Flow Series

GEIGER-GJ56.. with mechanical end stop For Venetian blinds and exterior blinds

Corso Principi di Piemonte, 65/ RACCONIGI (CN) ITALY tel fax

12V PORTABLE PRESSURE PUMP

Wilo SP Series Submersible Utility Pumps ETT. ETT Installation and operating instructions

SINGLE-PHASE PUMP START AND PROTECTION BOX Type V1M, V1N, V1E, V1F

READ THIS MANUAL CAREFULLY BEFORE USING THE PUMP

PEDESTAL SUMP PUMP. MODEL # Español p. 11. Zoeller is a registered trademark of Zoeller Co. All Rights Reserved.

Professional Séries. Professional Séries. Model T03828 SUBMERSIBLE SUMP DUPLEX SYSTEM SUBMERSIBLE SUMP DUPLEX SYSTEM. 1/3HP 2400 GPH Head of 20 (6 m)

Bore Hole Pump Model Nos: CBB75 CBB100 Part Nos:

Technical FAQs Technical and Basic Pool Information

SUBMERSIBLE DIRTY WATER PUMP

Smart Charger 12-24V 60A, 1600W

2.0Ah BATTERY INSTRUCTION MANUAL

GEIGER-GJ5610v1 with mechanical end stop For Venetian blinds and exterior blinds for 100 V power supply

Submersible Effluent Pump

Installation and Operation Guide. Tundra HD 2500 Power Inverter. for the. Webasto BlueCool Truck System

Bigfoot Motorised Utility Vehicle Ba ery Operated Ride On Instruc on / Assembling Manual

Installation manual. Modbus Interface DIII EKMBDXA7V1. Installation manual Modbus Interface DIII. English

PAC 600 PAC 800 PAC 800 comfort

cause injury to humans and other physical damage. : Gives information that does not fall in the WARNING or CAUTION categories.

Submersible Pump BIA-B10A BIA-B15A BIA-B25A BIA-B40A BIA-B42A BIA-B15VA BIA-B25VA BIA-B40VA BIA-B75A BIA-B75VA BIA-B75KA BIA-B120G

Transcription:

DRENOX IT - ISTRUZIONI ORIGINALI IN LINGUA ITALIANA IT PAG. 1 EN PAG. 5 F PAG. 9 D PAG. 13 E PAG. 17 P PAG. 21 NL PAG. 25 DK PAG. 29 FIN PAG. 33 N PAG. 37 S PAG. 41 GR PAG. 45 PL PAG. 49 RO PAG. 53 H PAG. 57 CZ PAG. 61 TR PAG. 64 RUS PAG. 69

SUMMARY GB CHAPTER DESCRIPTION PAGE 1 FEATURES 5 2 USE AND LIMITATIONS 6 3 INSTALLATION 6 4 ELECTRIC CONNECTION 7 5 MAINTENANCE AND TROUBLE SHOOTING 8 - WARRANTY 79 SAFETY SYMBOLS Notice for safety. Please give particular care to following signs. Improper use may lead into electric shock. DANGER Improper use may lead into heavy risk for persons and things. Improper use may cause damage to pump or installation. ATTENTION Before installing the pump please carefully read this manual. Guarantee will not be activated in case of improper use. CHAPTER 1 FEATURES DRENOX range pumps are particularly suitable to pump rain water, drain water; they are used to de-water flooded rooms, to irrigate gardens and back yards, to transfer clear or muddy water, with pumps operating totally or partially immersed. Each pump is tested and packed very attentively. Please ensure pump has not been damaged during transport; if this occurs please phone the dealer, within 8 days from purchasing day. 5

CHAPTER 2 USE AND LIMITATIONS Pump cannot be used to move inflammable or dangerous liquids. Ensure pump never runs dry. Max. Temp. Of liquid: 50 C continuous duty Max. Immersion height: 7 m with 10 m of power cord Max. Free passage (80/7): 3 mm Max. Free passage (160/8, 250/10, 350/12): 6 mm Max. on/off cycles/hour: 30 equally spaced TYPE MIN. PRIMING LEVEL MIN. DRAINAGE LEVEL The linear express measures in chart are in millimeters, please refer to Pict. 1A and Pict. 1B START LEVEL STOP LEVEL WEIGHT Kg. PICTURE A B C D - DRENOX 80/7 80 mm 3 mm 250 mm 100 mm 5,7 DRENOX 160/8 96 mm 35 mm 320 mm 107 mm 6,5 DRENOX 250/10 96 mm 35 mm 351 mm 111 mm 7 DRENOX 350/12 96 mm 35 mm 351 mm 111 mm 8,5 Pump with less than 10 mt. supply cord cannot be used in open spaces. The min. priming level refers to completely submerged outlet. (See Pict. 1A-1B ref.a) DRENOX 80/7 can drain water up to 3mm. from ground, once pump is priming. (See Pict. 1A ref.b) CHAPTER 3 INSTALLATION When installing, please ensure pump is disconnected from electric current network. Please use handlebar to remove or lift pump up Please use a non-return valve in case pump is connected to fixed installation with rigid piping; this will avoid liquid circulating when pump has been turned off; use of a pipe fitting will allow easy disconnection of pump for maintenance Dimensions of drain well must allow max. 30 on/off cycles/hour (See USE AND HIS LIMITATIONS) Please use flexible pipe connected to pump by means of plastic fitting in case of temporary use of pump Use a rope to immerse pump and fasten it to pump's handlebar DRENOX is equipped with a prerated float switch (See Pict. 1/A and 1/B); please increase or decrease the free piece of float switch cable by making it sliding through the proper seat on the handlebar, when modifying the rating of float switch Pumps used besides or inside swimming pools, garden ponds or similar places may have special requirements 6

Make sure that float switch turns off pump, when at min. level of liquid. Make sure no obstacles stand in the way of float switch, during up/down swinging. DANGER This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance. CHAPTER 4 ELECTRIC CONNECTION Ensure tension and frequency of pump (read motor plate) and supply network are same. Installer must make sure that electric current network has ground wire conforming to current laws. Make sure that electric current network is provided with a high-sensitivity circuit-breaker =30 ma (DIN VDE 0100T739) SINGLE PHASE VERSION Single phase pumps are equipped with double ground contact plugs at top end of supply cord ; in this case grounding is done when plugging in. THREE PHASE VERSION In this case the ground wire ( yellow-green cable ) of supply cord must be connected to ground wire of electric current network. Ensure connection to electric current network by using an omnipolar-sectionned magneto thermic circuit-breaker. This will ensure effective disconnection from electric current network. OVERLOAD PROTECTION DRENOX range pumps have a built-in thermal overload with automatic reset. Further protections are not required. DRENOX range three phase pumps can be protected by using a magneto-thermic motor protector or a contactor with thermal relay; in both cases they have to be rated conforming to nominal power showed on motor plate. Eventual electric float switch must be connected to auxiliary connector buckles. ROTATION DIRECTION TESTING THREE PHASE PUMPS Water head and delivery are terribly effected by wrong rotation of shaft of pump motor. Clock wise rotation is correct ( upside view of pump ). When starting the pump, motor will ungergo an anti-clock wise back-kick. In this case test is positive; on contrary case, please disconnect pump from network and inverse two phases. 7

CONNECTIONS DIAGRAM (See diagrams Pict.2) A. Single phase manual pump B. Single phase automatic pump C. Three phase pump 1. START (green) 2. RUN (red) 3. COMMON (black) 4. CAPACITOR 5. SUPPLY CORD 6. GROMMET 7. PLUG 8. YELLOW-GREEN 9. WHITE 10. LIGHT BLUE <LINE> 11. BROWN <LINE> 12. FLOAT SWITCH CHAPTER 5 MAINTENANCE AND TROUBLE SHOOTING Before doing any operation, make sure pump is disconnected from electric current network. Power cord must be replaced by manufacturer or by Customer Service, using special tools. No maintenance is required when DRENOX range pumps operate in normal conditions. Occasionally maintenance of liquid ends and replacement of impeller may be required. FAULT POSSIBLE CAUSE REMEDY PUMP DOES NOT DELIVER, MOTOR DOES NOT RUN. PUMP DOES NOT DELIVER, MOTOR RUNS. PUMP DELIVERS REDUCED WATER INTERMITTENT WORKING (SINGLE PHASE VERSION) 1) No electric current supplying. - 2) Incorrect plugging in. Verify presence of electric current supply and plug in. 3) Circuit-breaker come into operation. Reinforce circuit-breaker. Please call electrician in case circuit-breaker comes again into operation. 4) Impeller blocked. Remove obstacle. 5) Motor or capacitor damaged. Call dealer. 1) Filter obstructed. Clean filter. 2) Non return valve blocked. Clean or replace valve. 1) Filter partially obstructed. Clean filter. 2) Delivery pipe partially obstructed. Remove obstacles. 3) Impeller worn off. Replace impeller. 4) Anticlockwise rotation ( three phase version). Inverse two phases 1) Solids obstruct impeller. Remove obstacles. 2) Too warm liquid. - 3) Motor broken. Call dealer. 8