SUMMARY GB CHAPTER DESCRIPTION PAGE 1 FEATURES 5 2 USE AND LIMITATIONS 6 3 INSTALLATION 6 4 ELECTRIC CONNECTION 7 5 MAINTENANCE AND TROUBLESHOOTING 8 - FIGURES 73 - WARRANTY 76 SAFETY SYMBOLS Notice for safety. Please give particular care to following signs. Improper use may lead into electric shock. DANGER Improper use may lead into heavy risk for persons and things. Improper use may cause damage to pump or installation. ATTENTION Before installing the pump please carefully read this manual. Guarantee will not be activated in case of improper use. CHAPTER 1 FEATURES BIOX range pumps are particularly suitable to remove dirty water with suspended solids. BIOX pumps are well sized and can be possibly utilized both in fixed or movable installations. BIOX pumps are used to transfer dirty water, waste water and sewage water. Each pump is tested and packed very attentively. Please ensure pump has not been damaged during transport; if this occurs please phone the dealer, within 8 days from purchasing day. 5
CHAPTER 2 USE AND HIS LIMITATIONS Pump cannot be used to move inflammable or dangerous liquids. Ensure pump never runs dry. MAX. TEMP.OF LIQUID: 50 C continuous duty to motor completely submerged MAX. IMMERSION HEIGHT: 7 m with 10 mt. of power cord MAX. FREE PASSAGE: 40 mm MAX.ON/OFFCYCLES/HOUR: 30 equally spaced TYPE MIN. PRIMING LEVEL MIN. DRAINAGE LEVEL START LEVEL STOP LEVEL WEIGHT Kg. PICTURE A B C D - BIOX 200/8 123 mm 45 mm 370 mm 250 mm 8,5 BIOX 300/10 123 mm 45 mm 400 mm 300 mm 9 BIOX 400/12 123 mm 45 mm 400 mm 300 mm 10 Pump with less than 10 mt. supply cord cannot be used in open spaces. The min. priming level refers to completely submerged outlet (See Pict. 1). CHAPTER 3 INSTALLATION When installing, please ensure pump is disconnected from electric current network. Please use handlebar to remove or lift pump up Please use a non-return valve in case pump is connected to fixed installation with rigid piping; this will avoid liquid circulating when pump has been turned off; use of a pipe fitting will allow easy disconnection of pump for maintenance Dimensions of drain well must allow max. 30 on/off cycles/hour (See USE AND HIS LIMITATIONS) Please use flexible pipe connected to pump by means of plastic fitting in case of temporary use of pump Use a rope to immerse pump and fasten it to pump's handlebar BIOX aut is equipped with a prerated float switch (See Pict. 1); please increase or decrease the free piece of float switch cable by making it sliding through the proper seat on the handlebar, when modifying the rating of float switch Pumps used besides or inside swimming pools, garden ponds or similar places may have special requirements Make sure that float switch turns off pump, when at min. level of liquid. Make sure no obstacles stand in the way of float switch, during up/down swinging. DANGER This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance. 6
CHAPTER 4 ELECTRIC CONNECTION Ensure tension and frequency of pump (read motor plate) and supply network are same. Installer must make sure that electric current network has ground wire conforming to current laws. Make sure that electric current network is provided with a high-sensitivity circuit-breaker =30 ma (DIN VDE 0100T739). SINGLE PHASE VERSION Single phase pumps are equipped with double ground contact plug at top end of supply cord ; in this case grounding is done when plugging in. THREE PHASE VERSION In this case the ground wire (yellow-green cable) of supply cord must be connected to ground wire of electric current network. Ensure connection to electric current network by using an omnipolar-sectionned magneto thermic circuit-breaker. This will ensure effective disconnection from electric current network. OVERLOAD PROTECTION BIOX range pumps have a built-in thermal overload with automatic reset. Further protections are not required. BIOX range three phase pumps can be protected by using a magneto-thermic motor protector or a contactor with thermal relay; in both cases they have to be rated conforming to nominal power showed on motor plate. Eventual electric float switch must be connected to auxiliary connector buckles. ROTATION DIRECTION TESTING THREE PHASE PUMPS Water head and delivery are terribly effected by wrong rotation of shaft of pump motor. Clock wise rotation is correct (upside view of pump). When startin the pump motor will ungergo an anti-clock wise back-kick. In this case test is positive; on contrary case, please disconnect pump from network and inverse two phases. CONNECTIONS DIAGRAM (See diagrams Pict.2) : A. Single phase manual pump B. Single phase automatic pump C. Three phase pump 1. START (green) 2. RUN (red) 3. COMMON (black) 4. CAPACITOR 5. SUPPLY CORD 6. GROMMET 7. PLUG 8. YELLOW-GREEN 9. WHITE 10. LIGHT BLUE <LINE> 11. BROWN <LINE> 12. FLOAT SWITCH 7
CHAPTER 5 MAINTENANCE AND TROUBLESHOOTING Before doing any operation, make sure pump is disconnected from electric current network. Power cord must be replaced by manufacturer or by Customer service, using special tools. No maintenance is required when BIOX range pumps operate in normal conditions. Occasionally maintenance of liquid ends and replacement of impeller may be required. FAULT POSSIBLE CAUSE REMEDY PUMP DOES NOT DELIVER, MOTOR DOES NOT RUN PUMP DOES NOT DELIVER, MOTOR RUNS PUMP DELIVERS REDUCED WATER INTERMITTENT WORKING 1) No electric current supplying. - 2) Incorrect plugging in. Verify presence of electric current supply and plug in. 3) Circuit-breaker come into operation. Reinforce circuit-breaker. Please call electrician in case circuit-breaker comes again into operation. 4) Impeller blocked. Remove obstacle. 5) Motor or capacitor damaged. Call dealer. 1) Filter obstructed. Clean filter. 2) Non return valve blocked. Clean or replace valve. 1) Filter partially obstructed. Clean filter. 2) Delivery pipe partially obstructed. Remove obstacles. 3) Impeller worn off. Replace impeller. 4) Anticlockwise rotation (three phase version). Inverse two phases. 1) Solids obstruct impeller. Remove obstacles. 2) Too warm liquid. - 3) Motor broken. Call dealer. 8