DRENOX SUBMERSIBLE SUMP PUMPS FOR DRAINING CLEAR WATER. Usage limitations

Similar documents
DRENOX IT - ISTRUZIONI ORIGINALI IN LINGUA ITALIANA

BIOXDPV 160/6 IT - ISTRUZIONI ORIGINALI IN LINGUA ITALIANA

VADA - V75-S PRODUCT OVERVIEW CONSTRUCTION USAGE LIMITATIONS MOTOR WARRANTY

1/2 HP SUMP PUMP OWNER'S MANUAL

Priox. The new range NOCCHI. Lenntech NOCCHI. Tel Fax waste water treatment

COLLECTION STATIONS AND WASTE WATER LIFTING DESIGN SPECIFICATIONS

WATERPRESS BOOSTER SETS WITH 24L HORIZONTAL EXPANSION TANK. Design features

TOP MULTI. Submersible multi-stage pumps TOP MULTI 1 TOP MULTI 2-3. PERFORMANCE RANGE Flow rate up to 120 l/min (7.2 m³/h) Head up to 42 m

VADA - V60-J PRODUCT OVERVIEW CONSTRUCTION MOTOR USAGE LIMITATIONS WARRANTY

Pumps UK. Domestic Drainage pumps.

SUBMERSIBLE SUMP PUMPS. CSM Range. Cast iron sump pump nomenclature CSM 240 V F

SUBMERSIBLE WATER PUMP

Submersible Electric Pumps for Solid-laden Wastewater. DOMO Series

OWNERS MANUAL ECODIVER

SUBMERSIBLE WATER PUMPS

Series description: Wilo-Drain STS 40

SUBMERSIBLE WATER PUMP OPERATING & MAINTENANCE INSTRUCTIONS. Model Nos. CSE400A. Part No iss 2

Fully Imported from Japan

All prices exclude VAT and Carriage CONTENTS

Series description: Wilo-Drain TM/TMW/TMR 32

Submersible Pumps. 5'' CS Series Pumps

Installation, Maintenance and Operation manual 4 Submersible sand fighter pump. Type: SSFP - Series

5" SUBMERSIBLE PUMPS. by Franklin Electric

SUBMERSIBLE PUMP HSE RANGE

SUBMERSIBLE PUMPS HSE RANGE OPERATING & MAINTENANCE INSTRUCTIONS GC0514

OWNER S MANUAL SUBMERSIBLE UTILITY PUMP

Sewage transport Submersible pumps

Dewatering Submersible sewage pumps

barmesapumps.com BP33 & BP & RPM Installation, Operation & Maintenance Manual Submersible Sump / Utility Pumps

SELF-PRIMING ELECTRIC PUMPS in AISI 304

SUBMERSIBLE PUMP RANGE

GRUNDFOS DATA BOOKLET AP, KP. Wastwater pumps 50 Hz

Electric submersible pumps SEMISOM for sewage water

77014 / Automatic Users Manual. Carefully read this entire Instruction Manual before using this product

OWNER S MANUAL. Submersible Sump Pumps Models: XQS33 (1/3 HP Sump Pump) XQS50 (1/2 HP Sump Pump) Suzhou Xin Qi Electric Co.,ltd

OWNER S MANUAL SELF-PRIMING PORTABLE UTILITY PUMP

TRITUS. Submersible pumps with grinder

SCX-A. Application. Specification

garden PUMP kit 1 Depth A & B must be less than 9m Max Depth C must be less than 9m Max GardenPump Inst 6/11/07 12:52 Page 1

SUBMERSIBLE PUMP HSE RANGE

Technical Data BEST 2~5. Stainless Steel Submersible Sump Pumps EBARA PUMPS AUSTRALIA PTY. LTD. Best 2-5_Techdata_SS_V10

Installation & Operating Manual

SUNC1200 / ITEM #40882 SUBMERSIBLE UTILITY PUMP OPERATIONS MANUAL

IP 900 W/KS & IP 900 D/KS

Part No. Model Max Lpm Max Head Volts Hp Passage Switch Outlet

Series description: Wilo-Drain TM/TMW/TMR 32

Series description: Wilo-Drain MTC

Unilift CC 7-A1 (240V,0.25kW, L/sec,1-7m)

SELF-PRIMING ELECTRIC PUMPS

SUBMERSIBLE PUMPS Lifting of wastewater containing little pollution 50 Hz

HOMA Product Range. Electric Submersible Sewage Pumps Ranges K, KX. The source for world wide pump technology. Discharge Size DN 200 up to DN 400

Model: PFUPPP M10. 1/4 HP 3450 RPM 60 Hz Submersible Utility Pump OWNER S MANUAL. Power-Flo Pumps & Systems PUMPS

Trouble Shooting Guide EWA, 3-phase (D2422)

Electric submersible pumps SEMISOM for sewage water

SUBMERSIBLE WATER PUMP

CMA-B-C-D. EBARA PUMPS EUROPE S.p.A. CENTRIFUGAL PUMPS

SPECIFICATIONS ULTIMAX SUB-SURFACE DIRECTIONAL AERATION SYSTEM

GD series Submersible Grinder Pump

KP V KP150.AV1 230V + vertical float KP150.A1 230V + ball float

Construction Data. VERTÌ Sub

5" SUBMERSIBLE PUMPS _ed.12/2014. Single member - Company subject to the control and coordination of Franklin Electric Co., Inc.

CP Centrifugal pumps PERFORMANCE RANGE INSTALLATION AND USE APPLICATION LIMITS PATENTS - TRADE MARKS - MODELS CONSTRUCTION AND SAFETY STANDARDS

DW-DW VOX. Submersible Sewage Pumps. cod REV. 01/05. notice: all specifications could be subject to change

CMA - B - C - D - CMR

SUBMERSIBLE WATER PUMP

WINNER 4N 4 SUBMERSED CENTRIFUGAL ELECTRIC PUMPS

Submersible Stainless Steel Semi-Vortex Pumps Pumps

SPECIFICATIONS OXYMAX SUB-SURFACE AERATION SYSTEM

SUNC3000 / Item #40885

Page - SPECIFICATIONS 200 SELECTION CHART 201 TYPE KEY 202 CURVE SPECIFICATIONS 203 PERFORMANCE CHART DW 204 PERFORMANCE CHART DW VOX 205

OPERATOR'S MANUAL SUBMERSIBLE PUMP WSP50AA WSP100AA BY: AHM American Honda Motor Co., Inc. All Rights Reserved.

VX-ST VORTEX. Submersible pumps in stainless steel. PERFORMANCE RANGE Flow rate up to 650 l/min (39 m³/h) Head up to 15 m

Vertical multi-stage pumps

2CP Twin-impeller pumps

Owner s Manual. I i i i i i i i i i i i i i i i i i i i i i I. SUBMERSIBLE PUMP WSP50 l WSPlOO I I I I I I I I I I I I I I I I I I I I I

- CONSTRUCTIONS 300 SECTIONAL VIEW 300 BEARINGS 301 MECHANICAL SEAL 301

Professional Séries. Professional Séries. Model T03828 SUBMERSIBLE SUMP DUPLEX SYSTEM SUBMERSIBLE SUMP DUPLEX SYSTEM. 1/3HP 2400 GPH Head of 20 (6 m)

- Tel.: Fax :

No: Revision Operation & maintenance manual. BRAVO SLURRY PUMPS

Unilift KP 150, KP 250, KP 350

AUTOMATIC SUBMERSIBLE UTILITY PUMP

- CONTENTS SPECIFICATIONS 200 SELECTION CHARTS 201 TYPE KEY 202 PERFORMANCE CHART DW 203 PERFORMANCE CHART DW VOX 204

Davey 4 Submersible. Borehole Pumps and Motors 4 BOREHOLE PUMPS AND MOTORS. Borehole Well with Pump and Motor. Water Table. Aquifer.

OPERATION & MAINTENANCE INSTRUCTIONS

DUMPER. Data Book 50 Hz

2CP. Twin-impeller pumps PERFORMANCE RANGE INSTALLATION AND USE APPLICATION LIMITS OPTIONALS AVAILABLE ON REQUEST CONSTRUCTION AND SAFETY STANDARDS

Operation & Maintenance Manual

Page - SPECIFICATIONS 200 SELECTION CHART 201 PERFORMANCE CHART BEST ONE 202 PERFORMANCE CHART BEST ONE VOX 203

- CONSTRUCTIONS 300 SECTIONAL VIEW 300 MECHANICAL SEAL 301 BEARINGS DIMENSIONS AND WEIGHT 400 PUMP 400 PACKING 401

Aqua Ultraviolet Sunami Series Pumps 1/3HP, 3/4HP, 3HP, 4HP, 5HP

Operation & Maintenance Manual

1. GENERAL SAFETY INSTRUCTIONS 2. GENERAL SAFETY RULES GENERAL OBSERVATIONS.

cause injury to humans and other physical damage. : Gives information that does not fall in the WARNING or CAUTION categories.

DRAINAGE PUMPS Type RLV

Centrifugal pumps. PERFORMANCE RANGE Flow rate up to 900 l/min (54 m³/h) Head up to 76 m

SPECIFICATIONS EFFLUENT/SUMP DUPLEX SYSTEM ZOELLER SUBMERSIBLE DEWATERING OR EFFLUENT PUMPS

Technical Data DML. Submersible Sewage Pumps with Single Channel Impeller. DML_Techdata_SS_V11 EBARA PUMPS AUSTRALIA PTY. LTD.

Installation, Operation and Maintenance Manual Stancor SSD & SL Series Pumps

(%$5$ PUMPS EUROPE S.p.A. &(175,)8*$/38036':2. &217(176 50Hz

Submersible Effluent Pump

Transcription:

DRENOX SUBMERSIBLE SUMP PUMPS FOR DRAINING CLEAR WATER The DRENOX series pumps are built entirely in AISI 304 stainless steel. Cooling of the motor is via a heat exchange chamber that allows the machine to work for long periods when not completely submerged. Equipped with Ø 32 mm hose adapter. Automatic version equipped with float switch. Applications - Drainage of seepage water, pumping of rain water, from a grating or drain, pumping of domestic waste water, drainage of environments, bathing and swimming pools, industrial applications - Fountains and water features - Surface irrigation Motor Usage limitations - Type of liquid: partially effluent and dirty clear water, non-aggressive liquids - Maximum liquid temperature 40 C - Maximum submersion under the water level 7m - Minimum drainage level 3 mm for model 80/7, 35 mm for the other models (manual version) - Free clearance of solids 3 mm for models 80/7, 6 mm for the other models - Dry motor with stainless steel casing - Level of protection IP68 - Class F insulation - Single phase power supply with capacitor permanently activated and thermal protection built into the motor winding - Three phase power supply with external protection provided by the user - Completely insulated cable connection chamber - Self-lubricating ball bearings - Speed of rotation 2850 rpm 4 DESIGN FEATURES 1 5 6 3 1 2 3 Component Pump body Suction grid Impeller Material X 5 CrNi 1810 (AISI 304) Stainless steel X 5 CrNi 1810 (AISI 304) Stainless steel X 5 CrNi 1810 (AISI 304) Cast stainless steel 4 Power cable 10 m H07 RN-F with plug 5 Motor shaft Stainless steel shaft with a ceramic facing at the points of seal wear 2 6 Seal Fixed double NBR 70 rubber seal with special sand guard V-ring. Oil chamber for seal lubrication. 150

80/7 DRENOX TABLE OF HYDRAULIC PERFORMANCE 12 10 8 350/12 6 250/10 4 160/8 2 Hm L / 1' Q m 3 / h 50 100 150 200 250 300 3 6 9 12 15 18 PUMP PERFORMANCE CODE MODEL N1031090 N1031100 DRENOX 80/7 DRENOX 80/7 AUT N1031020 DRENOX 160/8 N1031060 DRENOX 160/8 AUT N1031030 N1031070 N1031040 N1031080 DRENOX 250/10 DRENOX 250/10 AUT DRENOX 350/12 DRENOX 350/12 AUT Nominal Absorbed L/1' power power 10 VOLTAGE Amp. µf. Q HP kw HP kw m 3 /h 0,6 0,3 0,2 0,4 0,3 1 ~ 220 240 V 0,55 0,40 0,75 0,55 1 ~ 220 240 V 2,4 8 7 5,8 5 4,1 2,2 0,75 0,55 1,2 0,9 N1031110 DRENOX 350/12 T 1,1 0,8 1,6 1,2 Automatic version equipped with float switch 1 ~ 220 240 V 1,1 0,8 1,6 1,2 1 ~ 220 240 V 5,1 16 10,5 10 9,5 9 7,7 3 ~ 400 V 1,3 4,5 2 6,3 10 Discharge head in meters 40 2,4 60 3,6 5,4 3,3 1,8 80 4,8 120 7,2 160 9,6 9,4 8,5 7,6 7,2 5,1 4,0 240 14,4 300 18 6,5 3,4 1 10,5 10 9,5 9 7,7 6,5 3,4 1 1 DRENOX 151

GB INDEX Cap.1- Features Cap.2- Use and his limitations Cap.3- Installation Cap.4- Electric connections Cap.5- Maintenance and trouble shooting Notice for safety. Please give particular care to following signs. Improper use may lead into electric shock. Improper use may lead into heavy risk for persons and things. REMARK Improper use may cause damage to pump or installation. ATTENTION: Before installing the pump please carefully read this manual. Guarantee will not be activated in case of improper use. CHAP.1 FEATURES DRENOX range pumps are particularly suitable to pump rain water, drain water; they are used to de-water flooded rooms, to irrigate gardens and back yards, to transfer clear or muddy water, with pumps operating totally or partially immersed. Each pump is tested and packed very attentively. Please ensure pump has not been damaged during transport; if this occurs please phone the dealer, within 8 days from purchasing day. CHAP. 2 USE AND HIS LIMITATIONS REMARK Pump cannot be used to move inflammable or dangerous liquids. REMARK Ensure pump never runs dry. MAX. TEMP.OF LIQUID:... MAX. IMMERSION HEIGHT:... MAX. FREE PASSAGE: 80/7:... MAX. FREE PASSAGE: 160/8, 250/10, 350/12... MAX. ON/OFF CYCLES/HOUR:...... 50 C continuous duty 7 m with 10 mt. of power cord 3 mm 6 mm 30 equally spaced 4

GB The linear express measures in chart are in millimeters Please refer to Pict. 1A and Pict. 1B TYPE MIN. PRIMING LEVEL Picture DRENOX 80/7 DRENOX 160/8 DRENOX 250/10 DRENOX 350/12 A 80 mm 96 mm 96 mm 96 mm MIN. DRAINAGE LEVEL B 3 mm 35 mm 35 mm 35 mm START LEVEL STOP LEVEL WEIGHT Kg. C 250 mm 320 mm 351 mm 351 mm D 100 mm 107 mm 111 mm 111 mm 5,7 6,5 7 8,5 Pump with less than 10 mt. supply cord cannot be used in open spaces. The min. priming level refers to completely submerged outlet. (See Pict. 1A-1B ref.a) DRENOX 80/7 can drain water up to 3mm. from ground, once pump is priming. (See Pict. 1A ref.b) CHAP. 3 INSTALLATION When installing, please ensure pump is disconnected from electric current network. Please use handlebar to remove or lift pump up. Please use a non-return valve in case pump is connected to fixed installation with rigid piping; this will avoid liquid circulating when pump has been turned off; use of a pipe fitting will allow easy disconnection of pump for maintenance. Dimensions of drain well must allow max. 30 on/off cycles/hour. ( See USE AND HIS LIMITATIONS ) Please use flexible pipe connected to pump by means of plastic fitting in case of temporary use of pump. Use a rope to immerse pump and fasten it to pump's handlebar. DRENOX is equipped with a pre-rated float switch ( See Pict. 1/A and 1/B ); please increase or decrease the free piece of float switch cable by making it sliding through the proper seat on the handlebar, when modifying the rating of float switch. Pumps used besides or inside swimming pools, garden ponds or similar places may have special requirements. REMARK REMARK Make sure that float switch turns off pump, when at min. level of liquid. Make sure no obstacles stand in the way of float switch, during up/down swinging. CHAP. 4 ELECTRIC CONNECTION REMARK Ensure tension and frequency of pump ( read motor plate ) and supply network are same. Installer must make sure that electric current network has ground wire conforming to current laws. Make sure that electric current network is provided with a high-sensitivity circuit-breaker =30 ma (DIN VDE 0100T739) Single phase version Single phase pumps are equipped with double ground contact plugs at top end of supply cord ; in this case grounding is done when plugging in. Three phase version In this case the ground wire ( yellow-green cable ) of supply cord must be connected to ground wire of electric current network. Ensure connection to electric current network by using an omnipolar-sectionned magneto thermic circuit-breaker. This will ensure effective disconnection from electric current network. 5

GB Overload Protection DRENOX range pumps have a built-in thermal overload with automatic reset. Further protections are not required. DRENOX range three phase pumps can be protected by using a magneto-thermic motor protector or a contactor with thermal relay; in both cases they have to be rated conforming to nominal power showed on motor plate. Eventual electric float switch must be connected to auxiliary connector buckles. Rotation direction testing three phase pumps Water head and delivery are terribly effected by wrong rotation of shaft of pump motor. Clock wise rotation is correct ( upside view of pump ). When starting the pump, motor will ungergo an anti-clock wise back-kick. In this case test is positive; on contrary case, please disconnect pump from network and inverse two phases. CONNECTIONS DIAGRAM: A) Single phase manual pump B) Single phase automatic pump C) Three phase pump See diagrams Pict.2 See Pict. 2 1) START ( green ) 5) SUPPLY CORD 9) WHITE 2) RUN ( red ) 6) GROMMET 10) LIGHT BLUE < LINE > 3) COMMON ( black ) 7) PLUG 11) BROWN < LINE > 4) CAPACITOR 8) YELLOW-GREEN 12) FLOAT SWITCH CHAP. 5 MAINTENANCE AND TROUBLE SHOOTING Before doing any operation, make sure pump is disconnected from electric current network. Power cord must be replaced by manufacturer or by Customer service, using special tools. No maintenance is required when DRENOX range pumps operate in normal conditions. Occasionally maintenance of liquid ends and replacement of impeller may be required. FAULT POSSIBLE CAUSE REMEDY PUMP DOES NOT DELIVER, MOTOR DOES NOT RUN. 1) No electric current supplying. 2) Incorrect plugging in. 2) Verify presence of electric current supply and plug in. PUMP DOES NOT DELIVER, MOTOR RUNS. PUMP DELIVERS REDUCED WATER 3) Circuit-breaker come into operation. 4) Impeller blocked. 5) Motor or capacitor damaged. 1) Filter obstructed. 2) Non return valve blocked. 1) Filter partially obstructed. 2) Delivery pipe partially obstructed. 3) Impeller worn off. 4) Anticlockwise rotation ( three phase version). 3) Reinforce circuit-breaker. Please call electrician in case circuit-breaker comes again into operation. 4) Remove obstacle. 5) Call dealer. 1) Clean filter. 2) Clean or replace valve. 1) Clean filter. 2) Remove obstacles. 3) Replace impeller. 4) Inverse two phases. INTERMITTENT WORKING (SINGLE PHASE VERSION) 1) Solids obstruct impeller. 2) Too warm liquid. 3) Motor broken. 1) Remove obstacles. 3) Call dealer. 6

DRENOX DRENOX 80/7 TABLE OF SIZES AND WEIGHTS Model Dimensions mm. Minimum Start level drainage level Stop level Free bore Weight A B Ø C D E* F* G* DNM kg DRENOX 80/7 231 61 177 182 3 250 100 ø 3 1" 1/4 5,7 * Start and stop level refers to the version equipped with floating switch The minimum drainage level refers to the manual version 152

DRENOX DRENOX 160/8-250/10-350/12 TABLE OF SIZES AND WEIGHTS Model A DRENOX 160/8 300 DRENOX 250/10 338 B 94 94 Ø C * Start and stop level refers to the version equipped with floating switch The minimum drainage level refers to the manual version 177 177 D 182 182 Dimensions mm. Minimum Start level drainage level E* 35 35 F* G* Free bore DRENOX 350/12 338 94 177 182 35 351 111 ø 6 1" 1/4 8,5 320 351 Stop level 107 111 ø 6 ø 6 DNM 1" 1/4 1" 1/4 Weight kg 6,5 7 DRENOX 153