Ruud Commercial Achiever Series Package Gas/Electric Rooftop Unit

Similar documents
Rheem Commercial Classic Series Package Gas / Electric Rooftop Unit

PACKAGE GAS / ELECTRIC ROOFTOP UNITS

PACKAGE GAS / ELECTRIC ROOFTOP UNITS

SELF-CONTAINED COOLING PACKAGE UNITS

SELF-CONTAINED COOLING PACKAGE UNITS

Ruud Commercial Achiever Series Package Heat Pump

PACKAGE GAS / ELECTRIC ROOFTOP UNITS

Rheem Commercial Classic Series Package Gas Electric Unit

Ruud Commercial Achiever Series Package Gas Electric Unit

SELF-CONTAINED COOLING PACKAGE UNITS

Ruud Commercial Achiever Series Package Gas Electric Unit

PACKAGE AIR CONDITIONERS

Ruud Commercial Achiever Series Package Gas Electric Unit

Rheem Commercial Classic Series Package Gas Electric Unit

PACKAGE GAS / ELECTRIC ROOFTOP UNITS FORM NO. EXR REV. 4 Supersedes Form No. EXR Rev. 3

Package Gas Electric Unit

PACKAGE HEAT PUMP UNITS

MODEL: RJNL-C. Package Heat Pump. With ClearControl Nominal Sizes 7.5 & 10 Ton [26.4 & 35.2 kw] ASHRAE Compliant Models

Package Air Conditioners

PACKAGE GAS ELECTRIC UNITS

Rheem Commercial Value Series Package Gas Electric Unit

Rheem Commercial Classic Series Package Air Conditioner

Ruud Commercial Achiever Series Package Air Conditioner. Package Air Conditioner

SINGLE PACKAGE HEAT PUMPS

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

S/T Ratio. Input BTU/h

D M S 760 C01 A A 1 1

P6SP Series Rev A TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 6, 7½ and 10 Ton Packaged Electric Cooling Units EER Commercial System Units

Q6SP Series Rev A TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 7.5 and 10 Ton Packaged Electric Heat Pump Units with R-410A 11.

14 SEER R -410A PACKAGE GAS / ELECTRIC UNIT 2 to 5 TON

13 SEER PACKAGE GAS / ELECTRIC UNIT (3 Phase) 35 to 53 MBtuh

TECHNICAL GUIDE FLEXIBLE LIGHT COMMERCIAL UNIT CHAMPION SERIES (WORLD 50 HZ) SINGLE PACKAGE COOLING UNITS D1EB036, 048 AND 060 3, 4 & 5 NOMINAL TONS

Packaged Gas/Electric Rooftop Units

S5BP Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS

Q6SP Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 7.5 and 10 Ton Packaged Electric Heat Pump Units with R-410A 11.

TECHNICAL GUIDE DESCRIPTION SINGLE PACKAGE AIR CONDITIONERS AND SINGLE PACKAGE GAS/ELECTRIC UNITS PRELIMINARY DATA

PGAA SERIES 10 SEER CONVERTIBLE SINGLE PACKAGE GAS/ELECTRIC UNIT

RGMA Series Package Gas Electric SPECIFICATIONS

R6GP Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 6, 7½ and 10 Ton Packaged Gas/Electric Units, with R-410A WARRANTY

Tons BTU/h S.E.E.R* E.E.R** HSPF

R6GN Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Gas/Electric Units with R-410A WARRANTY

TECHNICAL GUIDE GENERAL SPECIFICATIONS COMMERCIAL SPLIT-SYSTEM COOLING UNITS FOUR PIPE SYSTEM OUTDOOR UNIT:

DESCRIPTION SINGLE PACKAGE GAS/ELECTRIC AIR COOLED AIR CONDITIONERS 2 THRU 5 NOMINAL TON FEATURING PTG-C-1108

High Cap. (Btuh) HSPF COP

CAS. Product Specifications. COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 20 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

CPC Commercial. 15- & 20-Ton, Three-Phase Packaged Air Conditioner. 20-Ton Cooling Capacity: 240,000 BTU/h

R-22, 13 SEER 60 Hertz

SUBMITTAL COVER SHEET

PGMD Series 10 SEER. International Comfort Products 651 Heil Quaker Avenue Lewisburg, Tn Part No

PHB SERIES 7-1/2 and 10 TON

Q6SP Series Rev A TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 7.5 and 10 Ton Packaged Electric Heat Pump Units 11.0 EER

TECHNICAL GUIDE R-410A AFFINITY SERIES DEQ, DEX, DEY AND DEZ MODELS 2-5 TON 60 Hertz

Ruud Commercial Achiever Series Package Heat Pump. Package Heat Pump

DESCRIPTION TECHNICAL GUIDE SINGLE PACKAGE GAS/ELECTRIC UNITS AND SINGLE PACKAGE AIR CONDITIONERS D(CE, CG) 036, 048, 060 & YTG-A-0207

Q6SD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Heat Pump, Single Phase

TECHNICAL GUIDE R-410A, 13 SEER LATITUDE SERIES 60 Hertz

PACKAGE HEAT PUMPS. Featuring Earth-Friendly R-410A Refrigerant RQNL-B HIGH EFFICIENCY 13-SEER SERIES RQPL-B HIGH EFFICIENCY 14-SEER SERIES

PCB COMMERCIAL SERIES

Operating Net Capacity BTU/h. Input BTU/h Efficiency. lbs (kg) PGR524040KGP* 23, ,000/26, /8 x 47 x 31-7/16

PHF SERIES THREE PHASE CONVERTIBLE SINGLE PACKAGE HEAT PUMP

Product Data. Features/Benefits. Omnizone 50XCA06-14 Air-Cooled Indoor Self-Contained Systems with Puron Refrigerant (R-410A) 5 to 12 Nominal Tons

PGC COMMERCIAL PACKAGED GAS/ELECTRIC

Product Data. Features/Benefits. OMNIZONE 50XCR06-24 Remote Air-Cooled Indoor Self-Contained Systems with PURON Refrigerant (R-410A)

R6GF Series Rev B TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Gas/Electric Units Two-Stage Heat/Cool with Variable Speed Blower

ASHRAE 90.1 COMPLIANT PACKAGED ROOFTOP ELECTRIC COOLING UNITS, R 410A, TONS 3 Phase, 50 Hz. BUILT TO LAST, EASY TO INSTALL AND SERVICE

SELF-CONTAINED HEAT PUMP PACKAGE UNITS

Ruud Achiever Value Series Package Gas Electric Unit

TECHNICAL SPECIFICATIONS

TECHNICAL GUIDE R-410A AFFINITY SERIES DNX, DNQ, DNZ MODELS 2-5 TON 60 Hertz

TECHNICAL GUIDE R-410A AFFINITY SERIES DEZ MODELS 2-5 TON 60 Hertz

Product Data. Features/Benefits 50JS SINGLE-PACKAGED HEAT PUMP 50 HZ UNITS 7 TO 18 KW (2 TO 5 NOMINAL TONS)

Packaged Cooling with Electric Heat Rooftop Units

Q6SE Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Heat Pump, Single Phase

DF6SF Series Rev B TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS

FLEXIBLE LIGHT COMMERCIAL UNIT TECHNICAL GUIDE CHAMPION PLUS SINGLE PACKAGE GAS/ELECTRIC AIR COOLED AIR CONDITIONERS 1-1/2 THROUGH 5 NOMINAL TON

GQ6SD Series. Single Packaged Heat Pump 13 SEER, R-410A 2-5 Ton Units TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS WARRANTY

Modular Variable Speed Air Handlers

Packaged Gas/Electric Rooftop Units

CHP

DCG Series. Submittal Data Form. 7½ - 12½ Ton Packaged Gas/ Electric Up to 11.3 EER / 80% AFUE

SUNLINE 2000 SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS DESCRIPTION FEATURES H4CE090 & H2CE120 & H1CE /2, 10, & 12-1/2 NOMINAL TONS

SUNLINE 2000 SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS 50 AND 60 HZ DESCRIPTION FEATURES

SUNLINE 2000 SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS FEATURES DESCRIPTION. H5CE090 & H3CE AND 10 NOMINAL TONS (World 50HZ)

TECHNICAL GUIDE R-410A AFFINITY SERIES BHZ MODELS 2-5 TON 60 Hertz

TECHNICAL GUIDE R-410A AFFINITY SERIES BHQ MODELS 2-5 TON 60 Hertz

R6GD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 13 SEER, Three Phase, Packaged Gas/ Electric Units with R-410A 3-5 Ton Units WARRANTY

PACKAGE AIR CONDITIONERS

COOLING, R 410A SINGLE PACKAGE ROOFTOP 5 10 TONS

S6BQ Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Split System 2-Stage Air Conditioner. 7 1/2 and 10 Ton rated at 11.2 EER and 12.

SUBMITTAL COVER SHEET

PGB SERIES 3thru6-1/3Ton. Belt Drive 10 SEER CONVERTIBLE SINGLE PACKAGE GAS/ELECTRIC UNIT

DESCRIPTION FEATURES

DESCRIPTION TECHNICAL GUIDE AFFINITY SERIES SINGLE PACKAGE GAS/ELECTRIC AIR COOLED AIR CONDITIONERS 2 THRU 5 NOMINAL TON FEATURING YTG-B-0807

Q6SD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 13 SEER, 7.7 HSPF Three Phase, Packaged Heat Pump 3-5 Ton Units WARRANTY

R8HE Series Rev A. Single-Phase and Three-Phase TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS

TECHNICAL SPECIFICATIONS

CAS. Product Specifications

PHF SERIES. THREE PHASE 50 Hz OPERATION CONVERTIBLE SINGLE PACKAGE HEAT PUMP

TECHNICAL GUIDE R-410A ECHELON SERIES BUX, BUQ AND BUZ MODELS 2-5 TON 60 Hertz

technical sales guide - 60Hz Ducted Split Units HIGH AMBIENT OPERATION 52 UPTO

Transcription:

Package Gas Electric RLNL-B Series Ruud Commercial Achiever Series Package Gas/Electric Rooftop Unit RKNL-B Standard Efficiency Series Nominal Sizes 5-25 Tons [52.8 & 87.9 kw] ASHRAE 90.-2007 Compliant Model Energy Star Compliant Model thru 2//09 25 TON MODEL IS OUTSIDE THE SCOPE OF AHRI STANDARD 40/60 Rely on Ruud. FORM NO. R22-856 REV.

Table of Contents TABLE OF CONTENTS Unit Features & Benefits...-7 Model Number Identification...8 Options...9 Selection Procedure...0 General Data...-22 General Data Notes...2 Gross Systems Performance Data...24-25 Indoor Airflow Performance...26-29 Electrical Data...0-2 Dimensional Data...-6 Accessories...7-49 Mechanical Specifications...50-55 Wiring Diagrams...56-59 Limited Warranty...60 2 Rely on Ruud.

Unit Features & Benefits STANDARD FEATURES INCLUDE: R-40A HFC refrigerant. Complete factory charged, wired and run tested. Scroll compressors with internal line break overload and high-pressure protection. Dual stage compressors. Convertible airflow vertical downflow or horizontal sideflow. TXV refrigerant metering system on each circuit. High Pressure and Low Pressure/Loss of charge protection standard on all models. Solid Core liquid line filter drier on each circuit. Single slab, single pass designed evaporator and condenser coils facilitate easy cleaning for maintaining high efficiencies. Cooling operation up to 25 degree F ambient. Foil faced insulation encapsulated throughout entire unit minimizes airborne fibers from the air stream. Hinged major access door with heavy-duty gasketing, /4 turn latches and door retainers. Slide Out Indoor fan assembly for added service convenience. Powder Paint Finish meets ASTMB7 steel coated on each side for maximum protection. G90 galvanized. Base pan with drawn supply and return opening for superior water management. Forkable base rails for easy handling and lifting. Single point electrical connections. Internally sloped slide out condensate pan conforms to ASHRAE 62 standards. High performance belt drive motor with variable pitch pulleys and quick adjust belt system. Permanently lubricated evaporator, condenser and gas heat inducer motors. Condenser motors are internally protected, totally enclosed with shaft down design. 2 inch filter standard with slide out design. Two stage gas valve, direct spark ignition, and induced draft for efficiency and reliability. Tubular heat exchange for long life and induced draft for efficiency and reliability. Solid state furnace control with on board diagnostics. 24 volt control system with resettable circuit breakers. Colored and labeled wiring. Copper tube/aluminum Fin coils. Rely on Ruud.

Unit Features & Benefits 2 4 8 5 Ruud Package equipment is designed from the ground up with the latest features and benefits required to compete in today s market. The clean design stands alone in the industry and is a testament to the quality, reliability, ease of installation and serviceability that goes into each unit. Outwardly, the large Ruud Commercial Series TM label ( ) identifies the brand to the customer. The sheet-metal cabinet ( 2 ) uses nothing less than 20-gauge material for structural components with an underlying coat of G90. To ensure the leak-proof integrity of these units, the design utilizes a top with a /8" drip lip ( ), gasket-protected panels and screws. The slanted outdoor coil protects the coil from hail damage ( 4 ). Every Ruud package unit uses the toughest finish in the industry, using electro deposition baked-on enamel tested to withstand a rigorous 000-hour salt spray test, per ASTM B7. Anything built to last must start with the right foundation. In this case, the foundation is 4-gauge, commercial-grade, fullperimeter base rails ( 5 ), which integrate fork slots and rigging holes to save set-up time on the job site. The base pan is stamped, which forms a -/8" flange around the supply and return opening and has eliminated the worry of water entering the conditioned space ( 6 ). The drainpan ( 7 ) is made of material that resists the growth of harmful bacteria and is sloped for the latest IAQ benefits. Furthermore, the drainpan slides out for easy cleaning. The insulation has been placed on the underside of the basepan, removing areas that would allow for potential moisture accumulation, which can facilitate growth of harmful bacteria. All insulation is secured with both adhesive and mechanical fasteners, and all edges are hidden. 6 6 During development, each unit was tested to U.L. 995, ANSI 2.47, AHRI 40-60 and other Ruud-required reliability tests. Ruud adheres to stringent IS0 9002 quality procedures, and each unit bears the U.L. and AHRI certification labels located on the unit nameplate ( 8 ). Contractors can rest assured that when a Ruud package unit arrives at the job, it is ready to go with a factory charge and quality checks. Access to all major compartments is from the front of the unit, including the filter and electrical compartment, blower compartment, furnace section, and outdoor section. Each panel is permanently embossed with the compartment name (control/filter access, blower access and furnace access). Electrical and filter compartment access is through a large, toolless, hinged-access panel with /4 turn latches. On the outside of the panel is the unit nameplate, which contains the model and serial number, electrical data and other important unit information. The unit charging chart is located on the inside of the electrical and filter compartment door. Electrical wiring diagrams are found on the control box cover, which allows contractors to move them to more readable locations. To the right of the control box the model and serial number can be found. Having this information on the inside will assure model identification for the life of the product. The production 0 line quality test assurance label is also placed in this location ( 9 ). The two-inch 9 throwaway filters ( 0 ) are easily removed on a tracked system for easy replacement. 7 4 Rely on Ruud.

Unit Features & Benefits 0 Inside the control box ( ), each electrical component is clearly identified with a label that matches the component to the wire diagram for ease of trouble shooting. All wiring is numbered on each end of the termination and color-coded to match the wiring diagram. The integrated furnace control, used to control furnace operation, incorporates a flashing LED trouble - shooting device. Flash codes are clearly outlined on the unit wiring diagram. The control transformer has a low voltage circuit breaker that trips if a low voltage electrical short occurs. There is a blower contactor and compressor contactor for each compressor. For added convenience in the field, a factory-installed convenience outlet and disconnect ( 2 ) are available. Low and High voltage can enter either from the side or through the base. Lowvoltage connections are made through the low-voltage terminal strip. For ease of access, the U.L.-required low voltage barrier can be temporarily removed for low-voltage termination and then reinstalled. The high-voltage connection is terminated at the high-voltage terminal block. The suggested mounting for the field-installed disconnect is on the exterior side of the electrical control box. 2 The blower compartment is to the right of the control box and can be accessed by /4 turn latches. To allow easy maintenance of the blower assembly, the entire assembly easily slides out by removing four #0 screws from the blower assembly. The adjustable motor pulley ( 4 ) can easily be adjusted by loosening the bolts on either side of the motor mount. Removing the bolts allows for easy removal of the blower pulley by pushing the blower assembly up to loosen the belt. Once the belt is removed, the motor sheave can be adjusted to the desired number of turns, ranging from 0 to 6 turns open. Where the demands for the job require high static, Ruud has high-static drives available that deliver nominal airflow up to 2" of static. By referring to the airflow performance tables listed in the installation instructions, proper static pressure and CFM requirements can be dialed in. The scroll housing ( 5 ) and blower scroll provide quiet and efficient airflow. The blower sheave is secured by an H bushing which firmly secures the pulley to the blower shaft for years of trouble-free operation. The H bushing allows for easy removal of the blower pulley from the shaft, as opposed to the use of a set screw, which can score the shaft, creating burrs that make blowerpulley removal difficult. 5 4 In the outdoor section are the external gauge ports. ( ). With gauge ports mounted externally, an accurate diagnostic of system operation can be performed quickly and easily. Rely on Ruud. 5

Unit Features & Benefits Also inside the blower compartment are the optional low-ambient controls ( 6 ). The lowambient controls allow for operation of the compressor down to 0 degrees ambient temperature by cycling the outdoor fans on high pressure. Use of polarized plugs and schrader fittings allow for easy field or factory installation. 6 Inside the blower compartment the interlaced evaporator can also be viewed. The evaporator uses enhanced fin technology for maximum heat transfer. The TXV metering device assures even distribution of refrigerant throughout the evaporator. Wiring throughout the unit is neatly bundled and routed. Where wire harnesses go through the condenser bulkhead or blower deck, a molded wire harness assembly ( 7 ) provides an air-tight and water-tight seal, and provides strain relief. Care is 7 also taken to tuck raw edges of insulation behind sheet metal to improve indoor air quality. The furnace compartment contains the latest furnace technology on the market. The draft inducers ( 8 ) draw the flame from the Ruud exclusive in-shot burners ( 9 ) into the aluminized tubular heat exchanger ( 20 ) for clean, efficient gas heat. Stainless steel heat exchangers can be factory installed for those applications that have high fresh-air requirements, or applications in corrosive environments. Each furnace is equipment with a two-stage gas valve ( 2 ), which provides two stages of gas heat input. The first stage operates at 50% of the second stage (full fire). 8% steady state efficiency is maintained on both first and second stage by staging the multiple inducers to optimize the combustion airflow and maintain a near stoichiometric burn at each stage. 9 20 The direct spark igniter ( 22 ) assures reliable ignition in the most adverse conditions. This is coupled with remote flame sense ( 2 ) to assure that the flame has carried across the entire length of the burner assembly. Gas supply can be routed from the side or up through the base. Each furnace has the following safety devices to assure consistent and reliable operation after ignition: Pressures switches ( 24 ) to assure adequate combustion airflow before ignition. Rollout switches ( 25 ) to assure no obstruction or cracks in the heat exchanger. A limit device that protects the furnace from over-temperature problems. 24 8 24 8 24 2 8 8 25 25 25 25 22 25 9 2 6 Rely on Ruud.

Unit Features & Benefits 28 27 26 The compressor compartment houses the heartbeat of the unit. The scroll compressor ( 26 ) is known for its long life, and for reliable, quiet, and efficient operation. The suction and discharge lines are designed with shock loops ( 27 ) to absorb the strain and stress that the starting torque, steady state operation, and shut down cycle impose on the refrigerant tubing. Each compressor and circuit is independent for built-in redundancy, and each circuit is clearly marked throughout the system. Each unit has two stages of efficient cooling operation, first stage is approximately 50% of second stage. The low-pressure switches ( 28 ) and high-pressure switches ( 29 ) are mounted on the appropriate refrigerant lines in the con - denser section. The high-pressure switch will shut off the compressors if pressures exceeding 60 PSIG are detected as may occur if the outdoor fan motor fails. The low-pressure switches shut off the compressors if low pressure is detected due to loss of refrigerant charge. The optional freeze stats clip on the suction line above the compressor and wires into the low voltage plugs after removing a prewired jumper. The freeze stat protects the compressor if the evaporator coil gets too cold (below freezing) due to low airflow. Each factory-installed option is brazed into the appropriate high or low side and wired appropriately. Use of polarized plugs and schrader fittings allow for easy field installation. The condenser fan motor ( 0 ) can easily be accessed and maintained by removing the protective fan grille. The polarized plug connection allows the motor to be changed quickly and eliminates the need to snake wires through the unit. The outdoor coil uses the latest enhanced fin design ( ) for the most effective method of heat transfer. The outdoor coil is slanted to protect it from Mother Nature. 29 Each unit is designed for both downflow or horizontal applications ( 2 ) for job configuration flexibility. The return air compartment can also contain an economizer ( ). Two models exits, one for downflow applications, and one for horizontal applications. Each unit is pre-wired for the economizer to allow quick plug-in installation. The downflow economizer is also available as a factory-installed option. Exhaust is easily field-installed. The economizer, which provides free cooling when outdoor conditions are suitable and also provides fresh air to meet local requirements, comes standard with single enthalpy controls. The controls can be upgraded to dual enthalpy easily in the field. The direct drive actuator combined with gear drive dampers has eliminated the need for linkage adjustment in the field. The economizer control has a minimum position setpoint, an outdoor-air setpoint, a mix-air setpoint, and a CO 2 setpoint. Barometric relief is standard on all economizers. The power exhaust is housed in the barometric relief opening and is easily slipped in with a plug-in assembly. The Ruud roofcurb ( 4 ) is made for toolless assembly at the jobsite by inserting a pin into a hinge in each corner of the adjacent curb sides ( 5 ), which makes the assembly process quick and easy. 5 2 4 0 Rely on Ruud. 7

Model Number Identification R K N L B 80 C L 25 E X X X Economizer Option (See Next Page) Factory Installed Options (See Next Page) Ignition System E = Electric Heating Capacity (MBH) 25 = 250,000 [7.27] 5 Ton 0 = 00,000 [87.92] 20/25 Ton 5 = 50,000 [02.57] 5 Ton 40 = 400,000 [7.2] 20/25 Ton Drive Package L = Belt Drive M= Belt Drive High Static N = Belt Drive Field Installed Electrical Designation C = 208-20 V, PH, 60 Hz D = V, PH, 60 Hz Y = V, PH, 60 Hz Cooling Capacity (BTUH) [kw] 80 = 80,000 [52.75] 20 = 20,000 [6.50] 240 = 240,000 [70.4] 00 = 00,000 [87.92] Future Technical Variations Design Series L = R40A Refrigerant Efficiency Designation N = High Efficiency EnergyStar Compliant ASHRAE 90.-2007 Compliant Product Classification K = Rooftop Commercial Tradebrand R = Ruud Packaged Gas/Electric 8 Rely on Ruud.

Options FACTORY INSTALLED OPTION CODES FOR RKNL-B 80/20/240/00 Option Code AA AD AJ AH AP Hail Guard x Stainless Steel Heat Exchanger x NO OPTIONS Non-ed Convenience Outlet/Unfused Service Disconnect BF x x BG x x x Low Ambient/ Freeze Stat BY x x JB x x CR x x x CW x x x DN x x x x x indicates factory installed option. x ECONOMIZER SELECTION FOR RKNL-B 80/20/240/00 Option Code A F G x indicates factory installed option. *Downflow economizer only. No Economizer x Single Enthalpy Economizer* With Barometric Relief x Single Enthalpy Economizer* With Barometric Relief and Smoke Detector x Instructions for Factory Installed Option(s) Selection Note: Three characters following the model number will be utilized to designate a factory-installed option or combination of options. If no factory option(s) is required, nothing follows the model number. Step. After a basic rooftop model is selected, choose a two-character option code from the FACTORY INSTALLED OPTION SELECTION TABLE. Proceed to Step 2. Step 2. The last option code character is utilized for factory-installed economizers. Choose a character from the FACTORY INSTALLED ECONOMIZER SELECTION TABLE. Example: RKNL-B240CL40EXXX (where XX is factory installed option) Example: No Options RKNL-B240CL40E Example: No option with factory installed economizer RKNL-B240CL40EAAF Example: Options with low ambient and freeze stat, unwired convenience outlet, unfused service disconnect, and stainless steel heat exchanger with no factory installed economizer RKNL-B240CL40ECWA Example: Options same as above with factory installed economizer RKNL-B240CL40ECWF Rely on Ruud. 9

Selection Procedure To select an RKNL-B Cooling and Heating unit to meet a job require ment, follow this procedure, with example, using data supplied in this specification sheet.. DETERMINE COOLING AND HEATING REQUIREMENTS AND SPECIFIC OPERATING CONDITIONS FROM PLANS AND SPECS. Example: Voltage 208/240V Phase Total cooling capacity 205,000 BTUH [60. kw] Sensible cooling capacity 55,000 BTUH [45.4 kw] Heating capacity 25,000 BTUH [68.9 kw] *Condenser Entering Air 95 F [5 C] DB *Evaporator Mixed Air Entering 65 F [8 C] WB; 78 F [26 C] DB *Indoor Air Flow (vertical) 7200 CFM [98 L/s] *External Static Pressure.70 in. WG 2. SELECT UNIT TO MEET COOLING REQUIREMENTS. Since total cooling is within the range of a nominal 20 ton [70. kw] unit, enter cooling performance table at 95 F [5 C] DB condenser inlet air. Interpolate between 6 F [2 C] and 67 F [9 C] to determine total and sensible capacity and power input for 65 F [8 C] WB evap inlet air at 7725 CFM [646 L/s] indoor air flow (table basis): Total Capacity = 28,00 BTUH [69.78 kw] Sensible Capacity = 92,500 BTUH [56.7 kw] Input (Compressor and Cond. Fans) = 8,200 watts Use formula in note ➀ to determine sensible capacity at 78 F [26 C] DB evaporator entering air: Sensible Capacity = 77,400 BTUH [5.95 kw]. CORRECT CAPACITIES OF STEP 2 FOR ACTUAL AIR FLOW. Select factors from airflow correction table at 7200 CFM [98 L/s] and apply to data obtained in step 2 to obtain gross capacity: Total Capacity, 28,00 x.99 = 25,900 BTUH [69.08 kw] Sensible Capacity, 77,400 x.96 = 70,00 BTUH [49.87 kw] Input 8,200 x.99 = 8,08 Watts These are Gross Capacities, not corrected for blower motor heat or power. 5. CALCULATE INDOOR BLOWER BTUH HEAT EFFECT FROM MOTOR WATTS, STEP 4. BTUH = 2,862 x.42 = 9,765 6. CALCULATE NET COOLING CAPACITIES, EQUAL TO GROSS CAPACITY, STEP, MINUS INDOOR BLOWER MOTOR HEAT. Net Total Capacity = 25,900 9,765 = 226,5 BTUH [66.22 kw] Net Sensible Capacity = 70,00 9,765 = 60,55 BTUH [47.0 kw] 7. CALCULATE UNIT INPUT AND JOB EER. Total Input = 8,08 (step ) + 2,862 (step 4) = 20,880 Watts EER = Net (step 6) = 226,5 = 0.8 Input, Watts (above) 20,880 8. SELECT UNIT HEATING CAPACITY. From Physical Data Table read that gas heating output (input rating x efficiency) is: Heating Capacity = 24,000 BTUH [7.2 kw] Choose Model RKNL-B240CL0E *NOTE: These operating conditions are typical of a commercial application in a 95 F/79 F [5 C/26 C] design area with indoor design of 76 F [24 C] DB and 50% RH and 0% ventilation air, with the unit roof mounted and centered on the zone it conditions by ducts. 4. DETERMINE BLOWER SPEED AND WATTS TO MEET SYSTEM DESIGN. Enter Indoor Blower performance table at 7200 CFM [98 L/s]. Total ESP (external static pressure) per the spec of.70 in. includes the system duct and grilles. Add from the table Component Air Resistance, 0.0 for wet coil, 0.08 for downflow air flow, for a total selection static pressure of.790 (.8) inches of water, and determine: RPM = 79 WATTS = 2,862 DRIVE = L (standard 5 H.P. motor) 0 Rely on Ruud.

General Data NOM. SIZES 5-25 TONS [52.8-87.9 kw] ENERGY STAR COMPLIANT MODELS Model B80CL25E B80CL5E B80CM25E B80CM5E Cooling Performance Gross Cooling Capacity Btu [kw] 88,000 [55.08] 88,000 [55.08] 88,000 [55.08] CONTINUED 88,000 [55.08] EER/SEER 2./NA./NA./NA./NA Nominal CFM/AHRI Rated CFM [L/s] 6000/5900 [28/2784] 6000/5900 [28/2784] 6000/5900 [28/2784] 6000/5900 [28/2784] AHRI Net Cooling Capacity Btu [kw] 82,000 [5.] 82,000 [5.] 82,000 [5.] 82,000 [5.] Net Sensible Capacity Btu [kw] 5,700 [9.76] 5,700 [9.76] 5,700 [9.76] 5,700 [9.76] Net Latent Capacity Btu [kw] 46,00 [.57] 46,00 [.57] 46,00 [.57] 46,00 [.57] Integrated Part Load Value.4.4.4.4 Net System kw 6.5 6.5 6.5 6.5 Heating Performance (Package Gas/Electric) 4 Heating Input Btu [kw] (st Stage /2nd Stage) 25,000/250,000 [6.62/7.25] 75,000/50,000 [5.27/02.55] 25,000/250,000 [6.62/7.25] 75,000/50,000 [5.27/02.55] Heating Output Btu [kw] (st Stage /2nd Stage) 0,500/20,000 [29.74/59.48] 42,000/284,000 [4.6/8.2] 0,500/20,000 [29.74/59.48] 42,000/284,000 [4.6/8.2] Temperature Rise Range F [ C] 5-45 [8./25] 0-60 [6.7/.] 5-45 [8./25] 0-60 [6.7/.] Steady State Efficiency (%) 8 8 8 8 No. Burners 0 4 0 4 No. Stages 2 2 2 2 Gas Connection Pipe Size in. [mm] 0.75 [9] 0.75 [9] 0.75 [9] 0.75 [9] Compressor No./Type 2/Scroll 2/Scroll 2/Scroll 2/Scroll Outdoor Sound Rating (db) 5 9 9 9 9 Outdoor Coil Fin Type Louvered Louvered Louvered Louvered Tube Type Rifled Rifled Rifled Rifled Tube Size in. [mm] OD 0.75 [9.5] 0.75 [9.5] 0.75 [9.5] 0.75 [9.5] Face Area sq. ft. [sq. m] 5. [4.95] 5. [4.95] 5. [4.95] 5. [4.95] Rows / FPI [FPcm] / 22 [9] / 22 [9] / 22 [9] / 22 [9] Indoor Coil Fin Type Louvered Louvered Louvered Louvered Tube Type Rifled Rifled Rifled Rifled Tube Size in. [mm] 0.75 [9.5] 0.75 [9.5] 0.75 [9.5] 0.75 [9.5] Face Area sq. ft. [sq. m] 26.67 [2.48] 26.67 [2.48] 26.67 [2.48] 26.67 [2.48] Rows / FPI [FPcm] 2 / 8 [7] 2 / 8 [7] 2 / 8 [7] 2 / 8 [7] Refrigerant Control TX Valves TX Valves TX Valves TX Valves Drain Connection No./Size in. [mm] / [25.4] / [25.4] / [25.4] / [25.4] Outdoor Fan Type Propeller Propeller Propeller Propeller No. Used/Diameter in. [mm] 4/24 [609.6] 4/24 [609.6] 4/24 [609.6] 4/24 [609.6] Drive Type/No. Speeds Direct/ Direct/ Direct/ Direct/ CFM [L/s] 6000 [7550] 6000 [7550] 6000 [7550] 6000 [7550] No. Motors/HP 4 at / HP 4 at / HP 4 at / HP 4 at / HP Motor RPM 075 075 075 075 Indoor Fan Type FC Centrifugal FC Centrifugal FC Centrifugal FC Centrifugal No. Used/Diameter in. [mm] 2/8x9 [457x229] 2/8x9 [457x229] 2/8x9 [457x229] 2/8x9 [457x229] Drive Type/No. Speeds Belt/Variable Belt/Variable Belt/Variable Belt/Variable No. Motors Motor HP 5 5 Motor RPM 725 725 725 725 Motor Frame Size 56 56 84 84 Filter Type Disposable Disposable Disposable Disposable Furnished Yes Yes Yes Yes (No.) Size Recommended in. [mm] (8)2x25x20 [5x65x508] (8)2x25x20 [5x65x508] (8)2x25x20 [5x65x508] (8)2x25x20 [5x65x508] Refrigerant Charge Oz. (Sys. /Sys. 2) [g] 205/2 [582/5982] 205/2 [582/5982] 205/2 [582/5982] 205/2 [582/5982] Weights Net Weight lbs. [kg] 958 [888] 97 [894] 987 [90] 2000 [907] Ship Weight lbs. [kg] 2058 [94] 207 [99] 2087 [947] 200 [95] See Page 2 for Notes. Rely on Ruud.

General Data NOM. SIZES 5-25 TONS [52.8-87.9 kw] ENERGY STAR COMPLIANT MODELS Model B80DL25E B80DL5E B80DM25E B80DM5E Cooling Performance Gross Cooling Capacity Btu [kw] 88,000 [55.08] 88,000 [55.08] 88,000 [55.08] CONTINUED 88,000 [55.08] EER/SEER 2./NA./NA./NA./NA Nominal CFM/AHRI Rated CFM [L/s] 6000/5900 [28/2784] 6000/5900 [28/2784] 6000/5900 [28/2784] 6000/5900 [28/2784] AHRI Net Cooling Capacity Btu [kw] 82,000 [5.] 82,000 [5.] 82,000 [5.] 82,000 [5.] Net Sensible Capacity Btu [kw] 5,700 [9.76] 5,700 [9.76] 5,700 [9.76] 5,700 [9.76] Net Latent Capacity Btu [kw] 46,00 [.57] 46,00 [.57] 46,00 [.57] 46,00 [.57] Integrated Part Load Value.4.4.4.4 Net System kw 6.5 6.5 6.5 6.5 Heating Performance (Package Gas/Electric) 4 Heating Input Btu [kw] (st Stage /2nd Stage) 25,000/250,000 [6.62/7.25]75,000/50,000 [5.27/02.55]25,000/250,000 [6.62/7.25]75,000/50,000 [5.27/02.55] Heating Output Btu [kw] (st Stage /2nd Stage) 0,500/20,000 [29.74/59.48] 42,000/284,000 [4.6/8.2] 0,500/20,000 [29.74/59.48] 42,000/284,000 [4.6/8.2] Temperature Rise Range F [ C] 5-45 [8./25] 0-60 [6.7/.] 5-45 [8./25] 0-60 [6.7/.] Steady State Efficiency (%) 8 8 8 8 No. Burners 0 4 0 4 No. Stages 2 2 2 2 Gas Connection Pipe Size in. [mm] 0.75 [9] 0.75 [9] 0.75 [9] 0.75 [9] Compressor No./Type 2/Scroll 2/Scroll 2/Scroll 2/Scroll Outdoor Sound Rating (db) 5 9 9 9 9 Outdoor Coil Fin Type Louvered Louvered Louvered Louvered Tube Type Rifled Rifled Rifled Rifled Tube Size in. [mm] OD 0.75 [9.5] 0.75 [9.5] 0.75 [9.5] 0.75 [9.5] Face Area sq. ft. [sq. m] 5. [4.95] 5. [4.95] 5. [4.95] 5. [4.95] Rows / FPI [FPcm] / 22 [9] / 22 [9] / 22 [9] / 22 [9] Indoor Coil Fin Type Louvered Louvered Louvered Louvered Tube Type Rifled Rifled Rifled Rifled Tube Size in. [mm] 0.75 [9.5] 0.75 [9.5] 0.75 [9.5] 0.75 [9.5] Face Area sq. ft. [sq. m] 26.67 [2.48] 26.67 [2.48] 26.67 [2.48] 26.67 [2.48] Rows / FPI [FPcm] 2 / 8 [7] 2 / 8 [7] 2 / 8 [7] 2 / 8 [7] Refrigerant Control TX Valves TX Valves TX Valves TX Valves Drain Connection No./Size in. [mm] / [25.4] / [25.4] / [25.4] / [25.4] Outdoor Fan Type Propeller Propeller Propeller Propeller No. Used/Diameter in. [mm] 4/24 [609.6] 4/24 [609.6] 4/24 [609.6] 4/24 [609.6] Drive Type/No. Speeds Direct/ Direct/ Direct/ Direct/ CFM [L/s] 6000 [7550] 6000 [7550] 6000 [7550] 6000 [7550] No. Motors/HP 4 at / HP 4 at / HP 4 at / HP 4 at / HP Motor RPM 075 075 075 075 Indoor Fan Type FC Centrifugal FC Centrifugal FC Centrifugal FC Centrifugal No. Used/Diameter in. [mm] 2/8x9 [457x229] 2/8x9 [457x229] 2/8x9 [457x229] 2/8x9 [457x229] Drive Type/No. Speeds Belt/Variable Belt/Variable Belt/Variable Belt/Variable No. Motors Motor HP 5 5 Motor RPM 725 725 725 725 Motor Frame Size 56 56 84 84 Filter Type Disposable Disposable Disposable Disposable Furnished Yes Yes Yes Yes (No.) Size Recommended in. [mm] (8)2x25x20 [5x65x508] (8)2x25x20 [5x65x508] (8)2x25x20 [5x65x508] (8)2x25x20 [5x65x508] Refrigerant Charge Oz. (Sys. /Sys. 2) [g] 205/2 [582/5982] 205/2 [582/5982] 205/2 [582/5982] 205/2 [582/5982] Weights Net Weight lbs. [kg] 958 [888] 97 [894] 987 [90] 2000 [907] Ship Weight lbs. [kg] 2058 [94] 207 [99] 2087 [947] 200 [95] See Page 2 for Notes. 2 Rely on Ruud.

General Data NOM. SIZES 5-25 TONS [52.8-87.9 kw] ENERGY STAR COMPLIANT MODELS Model B80YL5E B80YM5E B20CL25E B20CL5E Cooling Performance Gross Cooling Capacity Btu [kw] 88,000 [55.08] 88,000 [55.08] 22,000 [62.2] CONTINUED 22,000 [62.2] EER/SEER 2./NA./NA.6/NA.6/NA Nominal CFM/AHRI Rated CFM [L/s] 6000/5900 [28/2784] 6000/5900 [28/2784] 7000/7025 [0/5] 7000/7025 [0/5] AHRI Net Cooling Capacity Btu [kw] 82,000 [5.] 82,000 [5.] 204,000 [59.77] 204,000 [59.77] Net Sensible Capacity Btu [kw] 5,700 [9.76] 5,700 [9.76] 54,900 [45.9] 54,900 [45.9] Net Latent Capacity Btu [kw] 46,00 [.57] 46,00 [.57] 49,00 [4.9] 49,00 [4.9] Integrated Part Load Value.4.4.4.4 Net System kw 6.5 6.5 7.57 7.57 Heating Performance (Package Gas/Electric) 4 Heating Input Btu [kw] (st Stage /2nd Stage) 75,000/50,000 [5.27/02.55]75,000/50,000 [5.27/02.55] 25,000/250,000 [6.62/7.25] 75,000/50,000 [5.27/02.55] Heating Output Btu [kw] (st Stage /2nd Stage) 42,000/284,000 [4.6/8.2] 42,000/284,000 [4.6/8.2] 0,500/20,000 [29.74/59.48] 42,000/284,000 [4.6/8.2] Temperature Rise Range F [ C] 0-60 [6.7/.] 0-60 [6.7/.] 5-45 [8./25] 25-55 [.9/0.6] Steady State Efficiency (%) 8 8 8 8 No. Burners 4 4 0 4 No. Stages 2 2 2 2 Gas Connection Pipe Size in. [mm] 0.75 [9] 0.75 [9] 0.75 [9] 0.75 [9] Compressor No./Type 2/Scroll 2/Scroll 2/Scroll 2/Scroll Outdoor Sound Rating (db) 5 9 9 9 9 Outdoor Coil Fin Type Louvered Louvered Louvered Louvered Tube Type Rifled Rifled Rifled Rifled Tube Size in. [mm] OD 0.75 [9.5] 0.75 [9.5] 0.75 [9.5] 0.75 [9.5] Face Area sq. ft. [sq. m] 5. [4.95] 5. [4.95] 5. [4.95] 5. [4.95] Rows / FPI [FPcm] / 22 [9] / 22 [9] 2 / 8 [7] 2 / 8 [7] Indoor Coil Fin Type Louvered Louvered Louvered Louvered Tube Type Rifled Rifled Rifled Rifled Tube Size in. [mm] 0.75 [9.5] 0.75 [9.5] 0.75 [9.5] 0.75 [9.5] Face Area sq. ft. [sq. m] 26.67 [2.48] 26.67 [2.48] 26.67 [2.48] 26.67 [2.48] Rows / FPI [FPcm] 2 / 8 [7] 2 / 8 [7] 2 / 8 [7] 2 / 8 [7] Refrigerant Control TX Valves TX Valves TX Valves TX Valves Drain Connection No./Size in. [mm] / [25.4] / [25.4] / [25.4] / [25.4] Outdoor Fan Type Propeller Propeller Propeller Propeller No. Used/Diameter in. [mm] 4/24 [609.6] 4/24 [609.6] 4/24 [609.6] 4/24 [609.6] Drive Type/No. Speeds Direct/ Direct/ Direct/ Direct/ CFM [L/s] 6000 [7550] 6000 [7550] 4800 [6984] 4800 [6984] No. Motors/HP 4 at / HP 4 at / HP 4 at / HP 4 at / HP Motor RPM 075 075 075 075 Indoor Fan Type FC Centrifugal FC Centrifugal FC Centrifugal FC Centrifugal No. Used/Diameter in. [mm] 2/8x9 [457x229] 2/8x9 [457x229] 2/8x9 [457x229] 2/8x9 [457x229] Drive Type/No. Speeds Belt/Variable Belt/Variable Belt/Variable Belt/Variable No. Motors Motor HP 5 Motor RPM 725 725 725 725 Motor Frame Size 56 84 56 56 Filter Type Disposable Disposable Disposable Disposable Furnished Yes Yes Yes Yes (No.) Size Recommended in. [mm] (8)2x25x20 [5x65x508] (8)2x25x20 [5x65x508] (8)2x25x20 [5x65x508] (8)2x25x20 [5x65x508] Refrigerant Charge Oz. (Sys. /Sys. 2) [g] 205/2 [582/5982] 205/2 [582/5982] 294/02 [85/8562] 294/02 [85/8562] Weights Net Weight lbs. [kg] 986 [90] 205 [94] 245 [97] 258 [979] Ship Weight lbs. [kg] 2086 [946] 25 [959] 2272 [0] 2285 [06] See Page 2 for Notes. Rely on Ruud.

General Data NOM. SIZES 5-25 TONS [52.8-87.9 kw] ENERGY STAR COMPLIANT MODELS Model B240CL0E B240CL40E B240CM0E B240CM40E Cooling Performance Gross Cooling Capacity Btu [kw] 244,000 [7.49] 244,000 [7.49] 244,000 [7.49] CONTINUED 244,000 [7.49] EER/SEER 2./NA./NA./NA./NA Nominal CFM/AHRI Rated CFM [L/s] 8000/7725 [775/645] 8000/7725 [775/645] 8000/7725 [775/645] 8000/7725 [775/645] AHRI Net Cooling Capacity Btu [kw] 24,000 [68.56] 24,000 [68.56] 24,000 [68.56] 24,000 [68.56] Net Sensible Capacity Btu [kw] 7,600 [50.28] 7,600 [50.28] 7,600 [50.28] 7,600 [50.28] Net Latent Capacity Btu [kw] 62,400 [8.28] 62,400 [8.28] 62,400 [8.28] 62,400 [8.28] Integrated Part Load Value 2.2 2.2 2.2 2.2 Net System kw 2.04 2.04 2.04 2.04 Heating Performance (Package Gas/Electric) 4 Heating Input Btu [kw] (st Stage /2nd Stage) 50,000/00,000 [4.95/87.9] 200,000/400,000 [58.6/7.2] 50,000/00,000 [4.95/87.9] 200,000/400,000 [58.6/7.2] Heating Output Btu [kw] (st Stage /2nd Stage) 2,500/24,000 [5.6/7.2] 62,000/24,000 [47.47/94.9] 2,500/24,000 [5.6/7.2] 62,000/24,000 [47.47/94.9] Temperature Rise Range F [ C] 5-45 [8./25] 25-55 [.9/0.6] 5-45 [8./25] 25-55 [.9/0.6] Steady State Efficiency (%) 8 8 8 8 No. Burners 2 4 2 4 No. Stages 2 2 2 2 Gas Connection Pipe Size in. [mm] 0.75 [9] 0.75 [9] 0.75 [9] 0.75 [9] Compressor No./Type 2/Scroll 2/Scroll 2/Scroll 2/Scroll Outdoor Sound Rating (db) 5 9 9 9 9 Outdoor Coil Fin Type Louvered Louvered Louvered Louvered Tube Type Rifled Rifled Rifled Rifled Tube Size in. [mm] OD 0.75 [9.5] 0.75 [9.5] 0.75 [9.5] 0.75 [9.5] Face Area sq. ft. [sq. m] 5. [4.95] 5. [4.95] 5. [4.95] 5. [4.95] Rows / FPI [FPcm] 2 / 22 [9] 2 / 22 [9] 2 / 22 [9] 2 / 22 [9] Indoor Coil Fin Type Louvered Louvered Louvered Louvered Tube Type Rifled Rifled Rifled Rifled Tube Size in. [mm] 0.75 [9.5] 0.75 [9.5] 0.75 [9.5] 0.75 [9.5] Face Area sq. ft. [sq. m] 26.67 [2.48] 26.67 [2.48] 26.67 [2.48] 26.67 [2.48] Rows / FPI [FPcm] / [5] / [5] / [5] / [5] Refrigerant Control TX Valves TX Valves TX Valves TX Valves Drain Connection No./Size in. [mm] / [25.4] / [25.4] / [25.4] / [25.4] Outdoor Fan Type Propeller Propeller Propeller Propeller No. Used/Diameter in. [mm] 6/24 [609.6] 6/24 [609.6] 6/24 [609.6] 6/24 [609.6] Drive Type/No. Speeds Direct/ Direct/ Direct/ Direct/ CFM [L/s] 9800 [944] 9800 [944] 9800 [944] 9800 [944] No. Motors/HP 6 at / HP 6 at / HP 6 at / HP 6 at / HP Motor RPM 075 075 075 075 Indoor Fan Type FC Centrifugal FC Centrifugal FC Centrifugal FC Centrifugal No. Used/Diameter in. [mm] 2/8x9 [457x229] 2/8x9 [457x229] 2/8x9 [457x229] 2/8x9 [457x229] Drive Type/No. Speeds Belt/Variable Belt/Variable Belt/Variable Belt/Variable No. Motors Motor HP 5 5 7 /2 7 /2 Motor RPM 725 725 725 725 Motor Frame Size 84 84 2 2 Filter Type Disposable Disposable Disposable Disposable Furnished Yes Yes Yes Yes (No.) Size Recommended in. [mm] (8)2x25x20 [5x65x508] (8)2x25x20 [5x65x508] (8)2x25x20 [5x65x508] (8)2x25x20 [5x65x508] Refrigerant Charge Oz. (Sys. /Sys. 2) [g] 402/ [97/984] 402/ [97/984] 402/ [97/984] 402/ [97/984] Weights Net Weight lbs. [kg] 2289 [08] 20 [045] 227 [056] 24 [062] Ship Weight lbs. [kg] 289 [084] 240 [090] 2427 [0] 244 [07] See Page 2 for Notes. 4 Rely on Ruud.

General Data NOM. SIZES 5-25 TONS [52.8-87.9 kw] ENERGY STAR COMPLIANT MODELS Model B240CN0E B240CN40E B240DL0E B240DL40E Cooling Performance Gross Cooling Capacity Btu [kw] 244,000 [7.49] 244,000 [7.49] 244,000 [7.49] CONTINUED 244,000 [7.49] EER/SEER 2./NA./NA./NA./NA Nominal CFM/AHRI Rated CFM [L/s] 8000/7725 [775/645] 8000/7725 [775/645] 8000/7725 [775/645] 8000/7725 [775/645] AHRI Net Cooling Capacity Btu [kw] 24,000 [68.56] 24,000 [68.56] 24,000 [68.56] 24,000 [68.56] Net Sensible Capacity Btu [kw] 7,600 [50.28] 7,600 [50.28] 7,600 [50.28] 7,600 [50.28] Net Latent Capacity Btu [kw] 62,400 [8.28] 62,400 [8.28] 62,400 [8.28] 62,400 [8.28] Integrated Part Load Value 2.2 2.2 2.2 2.2 Net System kw 2.04 2.04 2.04 2.04 Heating Performance (Package Gas/Electric) 4 Heating Input Btu [kw] (st Stage /2nd Stage) 50,000/00,000 [4.95/87.9] 200,000/400,000 [58.6/7.2] 50,000/00,000 [4.95/87.9] 200,000/400,000 [58.6/7.2] Heating Output Btu [kw] (st Stage /2nd Stage) 2,500/24,000 [5.6/7.2] 62,000/24,000 [47.47/94.9] 2,500/24,000 [5.6/7.2] 62,000/24,000 [47.47/94.9] Temperature Rise Range F [ C] 5-45 [8./25] 25-55 [.9/0.6] 5-45 [8./25] 25-55 [.9/0.6] Steady State Efficiency (%) 8 8 8 8 No. Burners 2 4 2 4 No. Stages 2 2 2 2 Gas Connection Pipe Size in. [mm] 0.75 [9] 0.75 [9] 0.75 [9] 0.75 [9] Compressor No./Type 2/Scroll 2/Scroll 2/Scroll 2/Scroll Outdoor Sound Rating (db) 5 9 9 9 9 Outdoor Coil Fin Type Louvered Louvered Louvered Louvered Tube Type Rifled Rifled Rifled Rifled Tube Size in. [mm] OD 0.75 [9.5] 0.75 [9.5] 0.75 [9.5] 0.75 [9.5] Face Area sq. ft. [sq. m] 5. [4.95] 5. [4.95] 5. [4.95] 5. [4.95] Rows / FPI [FPcm] 2 / 22 [9] 2 / 22 [9] 2 / 22 [9] 2 / 22 [9] Indoor Coil Fin Type Louvered Louvered Louvered Louvered Tube Type Rifled Rifled Rifled Rifled Tube Size in. [mm] 0.75 [9.5] 0.75 [9.5] 0.75 [9.5] 0.75 [9.5] Face Area sq. ft. [sq. m] 26.67 [2.48] 26.67 [2.48] 26.67 [2.48] 26.67 [2.48] Rows / FPI [FPcm] / [5] / [5] / [5] / [5] Refrigerant Control TX Valves TX Valves TX Valves TX Valves Drain Connection No./Size in. [mm] / [25.4] / [25.4] / [25.4] / [25.4] Outdoor Fan Type Propeller Propeller Propeller Propeller No. Used/Diameter in. [mm] 6/24 [609.6] 6/24 [609.6] 6/24 [609.6] 6/24 [609.6] Drive Type/No. Speeds Direct/ Direct/ Direct/ Direct/ CFM [L/s] 9800 [944] 9800 [944] 9800 [944] 9800 [944] No. Motors/HP 6 at / HP 6 at / HP 6 at / HP 6 at / HP Motor RPM 075 075 075 075 Indoor Fan Type FC Centrifugal FC Centrifugal FC Centrifugal FC Centrifugal No. Used/Diameter in. [mm] 2/8x9 [457x229] 2/8x9 [457x229] 2/8x9 [457x229] 2/8x9 [457x229] Drive Type/No. Speeds Belt/Variable Belt/Variable Belt/Variable Belt/Variable No. Motors Motor HP 7 /2 7 /2 5 5 Motor RPM 725 725 725 725 Motor Frame Size 2 2 84 84 Filter Type Disposable Disposable Disposable Disposable Furnished Yes Yes Yes Yes (No.) Size Recommended in. [mm] (8)2x25x20 [5x65x508] (8)2x25x20 [5x65x508] (8)2x25x20 [5x65x508] (8)2x25x20 [5x65x508] Refrigerant Charge Oz. (Sys. /Sys. 2) [g] 402/ [97/984] 402/ [97/984] 402/ [97/984] 402/ [97/984] Weights Net Weight lbs. [kg] 225 [055] 240 [06] 2289 [08] 20 [045] Ship Weight lbs. [kg] 2425 [00] 2440 [07] 289 [084] 240 [090] See Page 2 for Notes. Rely on Ruud. 5

General Data NOM. SIZES 5-25 TONS [52.8-87.9 kw] ENERGY STAR COMPLIANT MODELS Model B240DM0E B240DM40E B240DN0E B240DN40E Cooling Performance Gross Cooling Capacity Btu [kw] 244,000 [7.49] 244,000 [7.49] 244,000 [7.49] CONTINUED 244,000 [7.49] EER/SEER 2./NA./NA./NA./NA Nominal CFM/AHRI Rated CFM [L/s] 8000/7725 [775/645] 8000/7725 [775/645] 8000/7725 [775/645] 8000/7725 [775/645] AHRI Net Cooling Capacity Btu [kw] 24,000 [68.56] 24,000 [68.56] 24,000 [68.56] 24,000 [68.56] Net Sensible Capacity Btu [kw] 7,600 [50.28] 7,600 [50.28] 7,600 [50.28] 7,600 [50.28] Net Latent Capacity Btu [kw] 62,400 [8.28] 62,400 [8.28] 62,400 [8.28] 62,400 [8.28] Integrated Part Load Value 2.2 2.2 2.2 2.2 Net System kw 2.04 2.04 2.04 2.04 Heating Performance (Package Gas/Electric) 4 Heating Input Btu [kw] (st Stage /2nd Stage) 50,000/00,000 [4.95/87.9] 200,000/400,000 [58.6/7.2] 50,000/00,000 [4.95/87.9] 200,000/400,000 [58.6/7.2] Heating Output Btu [kw] (st Stage /2nd Stage) 2,500/24,000 [5.6/7.2] 62,000/24,000 [47.47/94.9] 2,500/24,000 [5.6/7.2] 62,000/24,000 [47.47/94.9] Temperature Rise Range F [ C] 5-45 [8./25] 25-55 [.9/0.6] 5-45 [8./25] 25-55 [.9/0.6] Steady State Efficiency (%) 8 8 8 8 No. Burners 2 4 2 4 No. Stages 2 2 2 2 Gas Connection Pipe Size in. [mm] 0.75 [9] 0.75 [9] 0.75 [9] 0.75 [9] Compressor No./Type 2/Scroll 2/Scroll 2/Scroll 2/Scroll Outdoor Sound Rating (db) 5 9 9 9 9 Outdoor Coil Fin Type Louvered Louvered Louvered Louvered Tube Type Rifled Rifled Rifled Rifled Tube Size in. [mm] OD 0.75 [9.5] 0.75 [9.5] 0.75 [9.5] 0.75 [9.5] Face Area sq. ft. [sq. m] 5. [4.95] 5. [4.95] 5. [4.95] 5. [4.95] Rows / FPI [FPcm] 2 / 22 [9] 2 / 22 [9] 2 / 22 [9] 2 / 22 [9] Indoor Coil Fin Type Louvered Louvered Louvered Louvered Tube Type Rifled Rifled Rifled Rifled Tube Size in. [mm] 0.75 [9.5] 0.75 [9.5] 0.75 [9.5] 0.75 [9.5] Face Area sq. ft. [sq. m] 26.67 [2.48] 26.67 [2.48] 26.67 [2.48] 26.67 [2.48] Rows / FPI [FPcm] / [5] / [5] / [5] / [5] Refrigerant Control TX Valves TX Valves TX Valves TX Valves Drain Connection No./Size in. [mm] / [25.4] / [25.4] / [25.4] / [25.4] Outdoor Fan Type Propeller Propeller Propeller Propeller No. Used/Diameter in. [mm] 6/24 [609.6] 6/24 [609.6] 6/24 [609.6] 6/24 [609.6] Drive Type/No. Speeds Direct/ Direct/ Direct/ Direct/ CFM [L/s] 9800 [944] 9800 [944] 9800 [944] 9800 [944] No. Motors/HP 6 at / HP 6 at / HP 6 at / HP 6 at / HP Motor RPM 075 075 075 075 Indoor Fan Type FC Centrifugal FC Centrifugal FC Centrifugal FC Centrifugal No. Used/Diameter in. [mm] 2/8x9 [457x229] 2/8x9 [457x229] 2/8x9 [457x229] 2/8x9 [457x229] Drive Type/No. Speeds Belt/Variable Belt/Variable Belt/Variable Belt/Variable No. Motors Motor HP 7 /2 7 /2 7 /2 7 /2 Motor RPM 725 725 725 725 Motor Frame Size 84 2 84 2 Filter Type Disposable Disposable Disposable Disposable Furnished Yes Yes Yes Yes (No.) Size Recommended in. [mm] (8)2x25x20 [5x65x508] (8)2x25x20 [5x65x508] (8)2x25x20 [5x65x508] (8)2x25x20 [5x65x508] Refrigerant Charge Oz. (Sys. /Sys. 2) [g] 402/ [97/984] 402/ [97/984] 402/ [97/984] 402/ [97/984] Weights Net Weight lbs. [kg] 227 [056] 24 [062] 225 [055] 240 [06] Ship Weight lbs. [kg] 2427 [0] 244 [07] 2425 [00] 2440 [07] See Page 2 for Notes. 6 Rely on Ruud.

General Data NOM. SIZES 5-25 TONS [52.8-87.9 kw] ENERGY STAR COMPLIANT MODELS Model B240YL40E B240YM40E B240YN40E B00CL0E Cooling Performance Gross Cooling Capacity Btu [kw] 244,000 [7.49] 244,000 [7.49] 244,000 [7.49] CONTINUED 2,000 [9.42] EER/SEER 2./NA./NA./NA 0/NA Nominal CFM/AHRI Rated CFM [L/s] 8000/7725 [775/645] 8000/7725 [775/645] 8000/7725 [775/645] 0000/9475 [479/447] AHRI Net Cooling Capacity Btu [kw] 24,000 [68.56] 24,000 [68.56] 24,000 [68.56] 294,000 [86.4] Net Sensible Capacity Btu [kw] 7,600 [50.28] 7,600 [50.28] 7,600 [50.28] 24,00 [62.7] Net Latent Capacity Btu [kw] 62,400 [8.28] 62,400 [8.28] 62,400 [8.28] 79,900 [2.4] Integrated Part Load Value 2.2 2.2 2.2. Net System kw 2.04 2.04 2.04 29.9 Heating Performance (Package Gas/Electric) 4 Heating Input Btu [kw] (st Stage /2nd Stage) 200,000/400,000 [58.6/7.2] 200,000/400,000 [58.6/7.2] 200,000/400,000 [58.6/7.2] 50,000/00,000 [4.95/87.9] Heating Output Btu [kw] (st Stage /2nd Stage) 62,000/24,000 [47.47/94.9] 62,000/24,000 [47.47/94.9] 62,000/24,000 [47.47/94.9] 2,500/24,000 [5.6/7.2] Temperature Rise Range F [ C] 25-55 [.9/0.6] 25-55 [.9/0.6] 25-55 [.9/0.6] 0-40 [5.6/22.2] Steady State Efficiency (%) 8 8 8 8 No. Burners 4 4 4 2 No. Stages 2 2 2 2 Gas Connection Pipe Size in. [mm] 0.75 [9] 0.75 [9] 0.75 [9] 0.75 [9] Compressor No./Type 2/Scroll 2/Scroll 2/Scroll 2/Scroll Outdoor Sound Rating (db) 5 9 9 9 92 Outdoor Coil Fin Type Louvered Louvered Louvered Louvered Tube Type Rifled Rifled Rifled Rifled Tube Size in. [mm] OD 0.75 [9.5] 0.75 [9.5] 0.75 [9.5] 0.75 [9.5] Face Area sq. ft. [sq. m] 5. [4.95] 5. [4.95] 5. [4.95] 5. [4.95] Rows / FPI [FPcm] 2 / 22 [9] 2 / 22 [9] 2 / 22 [9] 2 / 22 [9] Indoor Coil Fin Type Louvered Louvered Louvered Louvered Tube Type Rifled Rifled Rifled Rifled Tube Size in. [mm] 0.75 [9.5] 0.75 [9.5] 0.75 [9.5] 0.75 [9.5] Face Area sq. ft. [sq. m] 26.67 [2.48] 26.67 [2.48] 26.67 [2.48] 26.67 [2.48] Rows / FPI [FPcm] / [5] / [5] / [5] 4 / 5 [6] Refrigerant Control TX Valves TX Valves TX Valves TX Valves Drain Connection No./Size in. [mm] / [25.4] / [25.4] / [25.4] / [25.4] Outdoor Fan Type Propeller Propeller Propeller Propeller No. Used/Diameter in. [mm] 6/24 [609.6] 6/24 [609.6] 6/24 [609.6] 6/24 [609.6] Drive Type/No. Speeds Direct/ Direct/ Direct/ Direct/ CFM [L/s] 9800 [944] 9800 [944] 9800 [944] 9800 [944] No. Motors/HP 6 at / HP 6 at / HP 6 at / HP 6 at / HP Motor RPM 075 075 075 075 Indoor Fan Type FC Centrifugal FC Centrifugal FC Centrifugal FC Centrifugal No. Used/Diameter in. [mm] 2/8x9 [457x229] 2/8x9 [457x229] 2/8x9 [457x229] 2/8x9 [457x229] Drive Type/No. Speeds Belt/Variable Belt/Variable Belt/Variable Belt/Variable No. Motors Motor HP 5 7 /2 7 /2 7 /2 Motor RPM 725 725 725 725 Motor Frame Size 84 2 2 2 Filter Type Disposable Disposable Disposable Disposable Furnished Yes Yes Yes Yes (No.) Size Recommended in. [mm] (8)2x25x20 [5x65x508] (8)2x25x20 [5x65x508] (8)2x25x20 [5x65x508] (8)2x25x20 [5x65x508] Refrigerant Charge Oz. (Sys. /Sys. 2) [g] 402/ [97/984] 402/ [97/984] 402/ [97/984] 9/57 [96/02] Weights Net Weight lbs. [kg] 22 [054] 26 [07] 260 [070] 288 [08] Ship Weight lbs. [kg] 242 [099] 246 [6] 2 [6] 2488 [29] See Page 2 for Notes. Rely on Ruud. 7

General Data NOM. SIZES 5-25 TONS [52.8-87.9 kw] ENERGY STAR COMPLIANT MODELS Model B00CL40E B00CM0E B00CM40E B00DL0E Cooling Performance Gross Cooling Capacity Btu [kw] 2,000 [9.42] 2,000 [9.42] 2,000 [9.42] CONTINUED 2,000 [9.42] EER/SEER 2 0/NA 0/NA 0/NA 0/NA Nominal CFM/AHRI Rated CFM [L/s] 0000/9475 [479/447] 0000/9475 [479/447] 0000/9475 [479/447] 0000/9475 [479/447] AHRI Net Cooling Capacity Btu [kw] 294,000 [86.4] 294,000 [86.4] 294,000 [86.4] 294,000 [86.4] Net Sensible Capacity Btu [kw] 24,00 [62.7] 24,00 [62.7] 24,00 [62.7] 24,00 [62.7] Net Latent Capacity Btu [kw] 79,900 [2.4] 79,900 [2.4] 79,900 [2.4] 79,900 [2.4] Integrated Part Load Value.... Net System kw 29.9 29.9 29.9 29.9 Heating Performance (Package Gas/Electric) 4 Heating Input Btu [kw] (st Stage /2nd Stage) 200,000/400,000 [58.6/7.2] 50,000/00,000 [4.95/87.9] 200,000/400,000 [58.6/7.2] 50,000/00,000 [4.95/87.9] Heating Output Btu [kw] (st Stage /2nd Stage) 62,000/24,000 [47.47/94.9] 2,500/24,000 [5.6/7.2] 62,000/24,000 [47.47/94.9] 2,500/24,000 [5.6/7.2] Temperature Rise Range F [ C] 5-45 [8./25] 0-40 [5.6/22.2] 5-45 [8./25] 0-40 [5.6/22.2] Steady State Efficiency (%) 8 8 8 8 No. Burners 4 2 4 2 No. Stages 2 2 2 2 Gas Connection Pipe Size in. [mm] 0.75 [9] 0.75 [9] 0.75 [9] 0.75 [9] Compressor No./Type 2/Scroll 2/Scroll 2/Scroll 2/Scroll Outdoor Sound Rating (db) 5 92 92 92 92 Outdoor Coil Fin Type Louvered Louvered Louvered Louvered Tube Type Rifled Rifled Rifled Rifled Tube Size in. [mm] OD 0.75 [9.5] 0.75 [9.5] 0.75 [9.5] 0.75 [9.5] Face Area sq. ft. [sq. m] 5. [4.95] 5. [4.95] 5. [4.95] 5. [4.95] Rows / FPI [FPcm] 2 / 22 [9] 2 / 22 [9] 2 / 22 [9] 2 / 22 [9] Indoor Coil Fin Type Louvered Louvered Louvered Louvered Tube Type Rifled Rifled Rifled Rifled Tube Size in. [mm] 0.75 [9.5] 0.75 [9.5] 0.75 [9.5] 0.75 [9.5] Face Area sq. ft. [sq. m] 26.67 [2.48] 26.67 [2.48] 26.67 [2.48] 26.67 [2.48] Rows / FPI [FPcm] 4 / 5 [6] 4 / 5 [6] 4 / 5 [6] 4 / 5 [6] Refrigerant Control TX Valves TX Valves TX Valves TX Valves Drain Connection No./Size in. [mm] / [25.4] / [25.4] / [25.4] / [25.4] Outdoor Fan Type Propeller Propeller Propeller Propeller No. Used/Diameter in. [mm] 6/24 [609.6] 6/24 [609.6] 6/24 [609.6] 6/24 [609.6] Drive Type/No. Speeds Direct/ Direct/ Direct/ Direct/ CFM [L/s] 9800 [944] 9800 [944] 9800 [944] 9800 [944] No. Motors/HP 6 at / HP 6 at / HP 6 at / HP 6 at / HP Motor RPM 075 075 075 075 Indoor Fan Type FC Centrifugal FC Centrifugal FC Centrifugal FC Centrifugal No. Used/Diameter in. [mm] 2/8x9 [457x229] 2/8x9 [457x229] 2/8x9 [457x229] 2/8x9 [457x229] Drive Type/No. Speeds Belt/Variable Belt/Variable Belt/Variable Belt/Variable No. Motors Motor HP 7 /2 0 0 7 /2 Motor RPM 725 725 725 725 Motor Frame Size 2 25 25 2 Filter Type Disposable Disposable Disposable Disposable Furnished Yes Yes Yes Yes (No.) Size Recommended in. [mm] (8)2x25x20 [5x65x508] (8)2x25x20 [5x65x508] (8)2x25x20 [5x65x508] (8)2x25x20 [5x65x508] Refrigerant Charge Oz. (Sys. /Sys. 2) [g] 9/57 [96/02] 9/57 [96/02] 9/57 [96/02] 9/57 [96/02] Weights Net Weight lbs. [kg] 2402 [090] 299 [088] 24 [095] 288 [08] Ship Weight lbs. [kg] 2502 [5] 2499 [4] 25 [40] 2488 [29] See Page 2 for Notes. 8 Rely on Ruud.

General Data NOM. SIZES 5-25 TONS [52.8-87.9 kw] ENERGY STAR COMPLIANT MODELS Model B00DL40E B00DM0E B00DM40E B00YL40E Cooling Performance Gross Cooling Capacity Btu [kw] 2,000 [9.42] 2,000 [9.42] 2,000 [9.42] CONTINUED 2,000 [9.42] EER/SEER 2 0/NA 0/NA 0/NA 0/NA Nominal CFM/AHRI Rated CFM [L/s] 0000/9475 [479/447] 0000/9475 [479/447] 0000/9475 [479/447] 0000/9475 [479/447] AHRI Net Cooling Capacity Btu [kw] 294,000 [86.4] 294,000 [86.4] 294,000 [86.4] 294,000 [86.4] Net Sensible Capacity Btu [kw] 24,00 [62.7] 24,00 [62.7] 24,00 [62.7] 24,00 [62.7] Net Latent Capacity Btu [kw] 79,900 [2.4] 79,900 [2.4] 79,900 [2.4] 79,900 [2.4] Integrated Part Load Value.... Net System kw 29.9 29.9 29.9 29.9 Heating Performance (Package Gas/Electric) 4 Heating Input Btu [kw] (st Stage /2nd Stage) 200,000/400,000 [58.6/7.2] 50,000/00,000 [4.95/87.9] 200,000/400,000 [58.6/7.2] 200,000/400,000 [58.6/7.2] Heating Output Btu [kw] (st Stage /2nd Stage) 62,000/24,000 [47.47/94.9] 2,500/24,000 [5.6/7.2] 62,000/24,000 [47.47/94.9] 62,000/24,000 [47.47/94.9] Temperature Rise Range F [ C] 5-45 [8./25] 0-40 [5.6/22.2] 5-45 [8./25] 5-45 [8./25] Steady State Efficiency (%) 8 8 8 8 No. Burners 4 2 4 4 No. Stages 2 2 2 2 Gas Connection Pipe Size in. [mm] 0.75 [9] 0.75 [9] 0.75 [9] 0.75 [9] Compressor No./Type 2/Scroll 2/Scroll 2/Scroll 2/Scroll Outdoor Sound Rating (db) 5 92 92 92 92 Outdoor Coil Fin Type Louvered Louvered Louvered Louvered Tube Type Rifled Rifled Rifled Rifled Tube Size in. [mm] OD 0.75 [9.5] 0.75 [9.5] 0.75 [9.5] 0.75 [9.5] Face Area sq. ft. [sq. m] 5. [4.95] 5. [4.95] 5. [4.95] 5. [4.95] Rows / FPI [FPcm] 2 / 22 [9] 2 / 22 [9] 2 / 22 [9] 2 / 22 [9] Indoor Coil Fin Type Louvered Louvered Louvered Louvered Tube Type Rifled Rifled Rifled Rifled Tube Size in. [mm] 0.75 [9.5] 0.75 [9.5] 0.75 [9.5] 0.75 [9.5] Face Area sq. ft. [sq. m] 26.67 [2.48] 26.67 [2.48] 26.67 [2.48] 26.67 [2.48] Rows / FPI [FPcm] 4 / 5 [6] 4 / 5 [6] 4 / 5 [6] 4 / 5 [6] Refrigerant Control TX Valves TX Valves TX Valves TX Valves Drain Connection No./Size in. [mm] / [25.4] / [25.4] / [25.4] / [25.4] Outdoor Fan Type Propeller Propeller Propeller Propeller No. Used/Diameter in. [mm] 6/24 [609.6] 6/24 [609.6] 6/24 [609.6] 6/24 [609.6] Drive Type/No. Speeds Direct/ Direct/ Direct/ Direct/ CFM [L/s] 9800 [944] 9800 [944] 9800 [944] 9800 [944] No. Motors/HP 6 at / HP 6 at / HP 6 at / HP 6 at / HP Motor RPM 075 075 075 075 Indoor Fan Type FC Centrifugal FC Centrifugal FC Centrifugal FC Centrifugal No. Used/Diameter in. [mm] 2/8x9 [457x229] 2/8x9 [457x229] 2/8x9 [457x229] 2/8x9 [457x229] Drive Type/No. Speeds Belt/Variable Belt/Variable Belt/Variable Belt/Variable No. Motors Motor HP 7 /2 0 0 7 /2 Motor RPM 725 725 725 725 Motor Frame Size 2 25 25 2 Filter Type Disposable Disposable Disposable Disposable Furnished Yes Yes Yes Yes (No.) Size Recommended in. [mm] (8)2x25x20 [5x65x508] (8)2x25x20 [5x65x508] (8)2x25x20 [5x65x508] (8)2x25x20 [5x65x508] Refrigerant Charge Oz. (Sys. /Sys. 2) [g] 9/57 [96/02] 9/57 [96/02] 9/57 [96/02] 9/57 [96/02] Weights Net Weight lbs. [kg] 2402 [090] 299 [088] 24 [095] 2422 [099] Ship Weight lbs. [kg] 2502 [5] 2499 [4] 25 [40] 2522 [44] See Page 2 for Notes. Rely on Ruud. 9

General Data NOM. SIZES 5-25 TONS [52.8-87.9 kw] ENERGY STAR COMPLIANT MODELS Model B20CM25E B20CM5E B20DL25E B20DL5E Cooling Performance Gross Cooling Capacity Btu [kw] 22,000 [62.2] 22,000 [62.2] 22,000 [62.2] CONTINUED 22,000 [62.2] EER/SEER 2.6/NA.6/NA.6/NA.6/NA Nominal CFM/AHRI Rated CFM [L/s] 7000/7025 [0/5] 7000/7025 [0/5] 7000/7025 [0/5] 7000/7025 [0/5] AHRI Net Cooling Capacity Btu [kw] 204,000 [59.77] 204,000 [59.77] 204,000 [59.77] 204,000 [59.77] Net Sensible Capacity Btu [kw] 54,900 [45.9] 54,900 [45.9] 54,900 [45.9] 54,900 [45.9] Net Latent Capacity Btu [kw] 49,00 [4.9] 49,00 [4.9] 49,00 [4.9] 49,00 [4.9] Integrated Part Load Value.4.4.4.4 Net System kw 7.57 7.57 7.57 7.57 Heating Performance (Package Gas/Electric) 4 Heating Input Btu [kw] (st Stage /2nd Stage) 25,000/250,000 [6.62/7.25] 75,000/50,000 [5.27/02.55] 25,000/250,000 [6.62/7.25] 75,000/50,000 [5.27/02.55] Heating Output Btu [kw] (st Stage /2nd Stage) 0,500/20,000 [29.74/59.48] 42,000/284,000 [4.6/8.2] 0,500/20,000 [29.74/59.48] 42,000/284,000 [4.6/8.2] Temperature Rise Range F [ C] 5-45 [8./25] 25-55 [.9/0.6] 5-45 [8./25] 25-55 [.9/0.6] Steady State Efficiency (%) 8 8 8 8 No. Burners 0 4 0 4 No. Stages 2 2 2 2 Gas Connection Pipe Size in. [mm] 0.75 [9] 0.75 [9] 0.75 [9] 0.75 [9] Compressor No./Type 2/Scroll 2/Scroll 2/Scroll 2/Scroll Outdoor Sound Rating (db) 5 9 9 9 9 Outdoor Coil Fin Type Louvered Louvered Louvered Louvered Tube Type Rifled Rifled Rifled Rifled Tube Size in. [mm] OD 0.75 [9.5] 0.75 [9.5] 0.75 [9.5] 0.75 [9.5] Face Area sq. ft. [sq. m] 5. [4.95] 5. [4.95] 5. [4.95] 5. [4.95] Rows / FPI [FPcm] 2 / 8 [7] 2 / 8 [7] 2 / 8 [7] 2 / 8 [7] Indoor Coil Fin Type Louvered Louvered Louvered Louvered Tube Type Rifled Rifled Rifled Rifled Tube Size in. [mm] 0.75 [9.5] 0.75 [9.5] 0.75 [9.5] 0.75 [9.5] Face Area sq. ft. [sq. m] 26.67 [2.48] 26.67 [2.48] 26.67 [2.48] 26.67 [2.48] Rows / FPI [FPcm] 2 / 8 [7] 2 / 8 [7] 2 / 8 [7] 2 / 8 [7] Refrigerant Control TX Valves TX Valves TX Valves TX Valves Drain Connection No./Size in. [mm] / [25.4] / [25.4] / [25.4] / [25.4] Outdoor Fan Type Propeller Propeller Propeller Propeller No. Used/Diameter in. [mm] 4/24 [609.6] 4/24 [609.6] 4/24 [609.6] 4/24 [609.6] Drive Type/No. Speeds Direct/ Direct/ Direct/ Direct/ CFM [L/s] 4800 [6984] 4800 [6984] 4800 [6984] 4800 [6984] No. Motors/HP 4 at / HP 4 at / HP 4 at / HP 4 at / HP Motor RPM 075 075 075 075 Indoor Fan Type FC Centrifugal FC Centrifugal FC Centrifugal FC Centrifugal No. Used/Diameter in. [mm] 2/8x9 [457x229] 2/8x9 [457x229] 2/8x9 [457x229] 2/8x9 [457x229] Drive Type/No. Speeds Belt/Variable Belt/Variable Belt/Variable Belt/Variable No. Motors Motor HP 5 5 Motor RPM 725 725 725 725 Motor Frame Size 84 84 56 56 Filter Type Disposable Disposable Disposable Disposable Furnished Yes Yes Yes Yes (No.) Size Recommended in. [mm] (8)2x25x20 [5x65x508] (8)2x25x20 [5x65x508] (8)2x25x20 [5x65x508] (8)2x25x20 [5x65x508] Refrigerant Charge Oz. (Sys. /Sys. 2) [g] 294/02 [85/8562] 294/02 [85/8562] 294/02 [85/8562] 294/02 [85/8562] Weights Net Weight lbs. [kg] 274 [986] 287 [992] 245 [97] 258 [979] Ship Weight lbs. [kg] 20 [044] 24 [050] 2272 [0] 2285 [06] See Page 2 for Notes. 20 Rely on Ruud.

General Data NOM. SIZES 5-25 TONS [52.8-87.9 kw] ENERGY STAR COMPLIANT MODELS Model B20DM25E B20DM5E B20YL5E B20YM5E Cooling Performance Gross Cooling Capacity Btu [kw] 22,000 [62.2] 22,000 [62.2] 22,000 [62.2] CONTINUED 22,000 [62.2] EER/SEER 2.6/NA.6/NA.6/NA.6/NA Nominal CFM/AHRI Rated CFM [L/s] 7000/7025 [0/5] 7000/7025 [0/5] 7000/7025 [0/5] 7000/7025 [0/5] AHRI Net Cooling Capacity Btu [kw] 204,000 [59.77] 204,000 [59.77] 204,000 [59.77] 204,000 [59.77] Net Sensible Capacity Btu [kw] 54,900 [45.9] 54,900 [45.9] 54,900 [45.9] 54,900 [45.9] Net Latent Capacity Btu [kw] 49,00 [4.9] 49,00 [4.9] 49,00 [4.9] 49,00 [4.9] Integrated Part Load Value.4.4.4.4 Net System kw 7.57 7.57 7.57 7.57 Heating Performance (Package Gas/Electric) 4 Heating Input Btu [kw] (st Stage /2nd Stage) 25,000/250,000 [6.62/7.25] 75,000/50,000 [5.27/02.55] 75,000/50,000 [5.27/02.55] 75,000/50,000 [5.27/02.55] Heating Output Btu [kw] (st Stage /2nd Stage) 0,500/20,000 [29.74/59.48] 42,000/284,000 [4.6/8.2] 42,000/284,000 [4.6/8.2] 42,000/284,000 [4.6/8.2] Temperature Rise Range F [ C] 5-45 [8./25] 25-55 [.9/0.6] 25-55 [.9/0.6] 025-55 [680.6/0.6] Steady State Efficiency (%) 8 8 8 8 No. Burners 0 4 4 4 No. Stages 2 2 2 2 Gas Connection Pipe Size in. [mm] 0.75 [9] 0.75 [9] 0.75 [9] 0.75 [9] Compressor No./Type 2/Scroll 2/Scroll 2/Scroll 2/Scroll Outdoor Sound Rating (db) 5 9 9 9 9 Outdoor Coil Fin Type Louvered Louvered Louvered Louvered Tube Type Rifled Rifled Rifled Rifled Tube Size in. [mm] OD 0.75 [9.5] 0.75 [9.5] 0.75 [9.5] 0.75 [9.5] Face Area sq. ft. [sq. m] 5. [4.95] 5. [4.95] 5. [4.95] 5. [4.95] Rows / FPI [FPcm] 2 / 8 [7] 2 / 8 [7] 2 / 8 [7] 2 / 8 [7] Indoor Coil Fin Type Louvered Louvered Louvered Louvered Tube Type Rifled Rifled Rifled Rifled Tube Size in. [mm] 0.75 [9.5] 0.75 [9.5] 0.75 [9.5] 0.75 [9.5] Face Area sq. ft. [sq. m] 26.67 [2.48] 26.67 [2.48] 26.67 [2.48] 26.67 [2.48] Rows / FPI [FPcm] 2 / 8 [7] 2 / 8 [7] 2 / 8 [7] 2 / 8 [7] Refrigerant Control TX Valves TX Valves TX Valves TX Valves Drain Connection No./Size in. [mm] / [25.4] / [25.4] / [25.4] / [25.4] Outdoor Fan Type Propeller Propeller Propeller Propeller No. Used/Diameter in. [mm] 4/24 [609.6] 4/24 [609.6] 4/24 [609.6] 4/24 [609.6] Drive Type/No. Speeds Direct/ Direct/ Direct/ Direct/ CFM [L/s] 4800 [6984] 4800 [6984] 4800 [6984] 4800 [6984] No. Motors/HP 4 at / HP 4 at / HP 4 at / HP 4 at / HP Motor RPM 075 075 075 075 Indoor Fan Type FC Centrifugal FC Centrifugal FC Centrifugal FC Centrifugal No. Used/Diameter in. [mm] 2/8x9 [457x229] 2/8x9 [457x229] 2/8x9 [457x229] 2/8x9 [457x229] Drive Type/No. Speeds Belt/Variable Belt/Variable Belt/Variable Belt/Variable No. Motors Motor HP 5 5 5 Motor RPM 725 725 725 725 Motor Frame Size 84 84 56 84 Filter Type Disposable Disposable Disposable Disposable Furnished Yes Yes Yes Yes (No.) Size Recommended in. [mm] (8)2x25x20 [5x65x508] (8)2x25x20 [5x65x508] (8)2x25x20 [5x65x508] (8)2x25x20 [5x65x508] Refrigerant Charge Oz. (Sys. /Sys. 2) [g] 294/02 [85/8562] 294/02 [85/8562] 294/02 [85/8562] 294/02 [85/8562] Weights Net Weight lbs. [kg] 274 [986] 287 [992] 27 [986] 2202 [999] Ship Weight lbs. [kg] 20 [044] 24 [050] 200 [04] 229 [056] See Page 2 for Notes. Rely on Ruud. 2

General Data NOM. SIZES 5-25 TONS [52.8-87.9 kw] ENERGY STAR COMPLIANT MODELS Model B00YM40E Cooling Performance Gross Cooling Capacity Btu [kw] 2,000 [9.42] EER/SEER 2 0/NA Nominal CFM/AHRI Rated CFM [L/s] 0000/9475 [479/447] AHRI Net Cooling Capacity Btu [kw] 294,000 [86.4] Net Sensible Capacity Btu [kw] 24,00 [62.7] Net Latent Capacity Btu [kw] 79,900 [2.4] Integrated Part Load Value. Net System kw 29.9 Heating Performance (Package Gas/Electric) 4 Heating Input Btu [kw] (st Stage /2nd Stage) 200,000/400,000 [58.6/7.2] Heating Output Btu [kw] (st Stage /2nd Stage) 62,000/24,000 [47.47/94.9] Temperature Rise Range F [ C] 5-45 [8./25] Steady State Efficiency (%) 8 No. Burners 4 No. Stages 2 Gas Connection Pipe Size in. [mm] 0.75 [9] Compressor No./Type 2/Scroll Outdoor Sound Rating (db) 5 92 Outdoor Coil Fin Type Louvered Tube Type Rifled Tube Size in. [mm] OD 0.75 [9.5] Face Area sq. ft. [sq. m] 5. [4.95] Rows / FPI [FPcm] 2 / 22 [9] Indoor Coil Fin Type Louvered Tube Type Rifled Tube Size in. [mm] 0.75 [9.5] Face Area sq. ft. [sq. m] 26.67 [2.48] Rows / FPI [FPcm] 4 / 5 [6] Refrigerant Control TX Valves Drain Connection No./Size in. [mm] / [25.4] Outdoor Fan Type Propeller No. Used/Diameter in. [mm] 6/24 [609.6] Drive Type/No. Speeds Direct/ CFM [L/s] 9800 [944] No. Motors/HP 6 at / HP Motor RPM 075 Indoor Fan Type FC Centrifugal No. Used/Diameter in. [mm] 2/8x9 [457x229] Drive Type/No. Speeds Belt/Variable No. Motors Motor HP 0 Motor RPM 725 Motor Frame Size 25 Filter Type Disposable Furnished Yes (No.) Size Recommended in. [mm] (8)2x25x20 [5x65x508] Refrigerant Charge Oz. (Sys. /Sys. 2) [g] 9/57 [96/02] Weights Net Weight lbs. [kg] 24 [04] Ship Weight lbs. [kg] 25 [49] See Page 2 for Notes. 22 Rely on Ruud.

General Data Notes NOTES:. Cooling Performance is rated at 95 F ambient, 80 F entering dry bulb, 67 F entering wet bulb. Gross capacity does not include the effect of fan motor heat. AHRI capacity is net and includes the effect of fan motor heat. Units are suitable for operation to 20% of nominal cfm. Units are certified in accordance with the Unitary Air Conditioner Equipment certification program, which is based on AHRI Standard 20/240 or 40/60. 2. EER and/or SEER are rated at AHRI conditions and in accordance with DOE test procedures.. Integrated Part Load Value is rated in accordance with AHRI Standard 20/240 or 60. Units are rated at 80 F ambient, 80 F entering dry bulb, and 67 F entering wet bulb at AHRI rated cfm. 4. Heating Performance limit settings and rating data were established and approved under laboratory test conditions using American National Standard Institute standards. Ratings shown are for elevations up to 2000 feet. For elevations above 2000 feet, ratings should be reduced at the rate of 4% for each 000 feet above sea level. 5. Outdoor Sound Rating shown is tested in accordance with AHRI Standard 270. 25 ton model (B00) is outside the scope of AHRI Standard 40/60. Rely on Ruud. 2

Gross Systems Performance Data GROSS SYSTEMS PERFORMANCE DATA B80 O UT D O O R D R Y B U LB T E M PE R AT U R E F [ C] 75 [2.9] 80 [26.7] 85 [29.4] 90 [2.2] 95 [5] 00 [7.8] 05 [40.6] 0 [4.] 5 [46.] ENTERING INDOOR AIR @ 80 F [26.7 C] dbe ➀ wbe 7 F [2.7 C] 67 F [9.4 C] 6 F [7.2 C] CFM [L/s] 7200 [98] 5900 [2784] 4800 [2265] 7200 [98] 5900 [2784] 4800 [2265] 7200 [98] 5900 [2784] 4800 [2265] DR ➀.04.08..04.08..04.08. 226.5 [66.4] 48.8 [4.6] 2.6 222.2 [65.] 46.6 [4.0]. 27.5 [6.7] 44. [42.2].8 22.5 [62.] 4.4 [4.5] 4.5 207.2 [60.7] 8.5 [40.6] 5.2 20.5 [59.] 5.4 [9.7] 6.0 95.5 [57.] 2.0 [8.7] 6.9 89.2 [55.4] 28.4 [7.6] 7.8 82.5 [5.5] 24.5 [6.5] 8.7 24 Rely on Ruud. 27.8 [6.8] 26.2 [7.0] 2. 2.6 [62.6] 24. [6.4] 2.9 209. [6.] 22. [5.9].5 204. [59.9] 20.0 [5.2] 4.2 99.2 [58.4] 7.6 [4.5] 4.9 9.7 [56.8] 5.0 [.7] 5.7 88.0 [55.] 2.2 [2.9] 6.5 8.9 [5.] 09. [2.0] 7.4 75.5 [5.4] 05.9 [.0] 8.4 20.4 [6.7] 08.5 [.8] 2. 206.4 [60.5] 06.9 [.] 2.7 202.0 [59.2] 05.2 [0.8]. 97.4 [57.9] 0. [0.] 4.0 92.4 [56.4] 0.2 [29.7] 4.7 87.2 [54.9] 99. [29.] 5.4 8.6 [5.2] 96.6 [28.] 6. 75.7 [5.5] 9.9 [27.5] 7. 69.5 [49.7] 9.2 [26.7] 8. 24. [62.8] 74. [5.0] 2.4 209.9 [6.5] 7.9 [50.4].0 205. [60.2] 69.5 [49.7].6 200.2 [58.7] 66.7 [48.9] 4. 94.9 [57.] 6.9 [48.0] 5. 89.2 [55.4] 60.7 [47.] 5.9 8.2 [5.7] 57. [46.] 6.7 76.9 [5.8] 5.7 [45.] 7.6 70.2 [49.9] 49.9 [4.9] 8.6 GROSS SYSTEMS PERFORMANCE DATA B20 O UT D O O R D R Y B U LB T E M PE R AT U R E F [ C] 75 [2.9] 80 [26.7] 85 [29.4] 90 [2.2] 95 [5] 00 [7.8] 05 [40.6] 0 [4.] 5 [46.] DR Depression ratio dbe Entering air dry bulb wbe Entering air wet bulb Total Total capacity x 000 BTUH Sens Sensible capacity x 000 BTUH KW input 206.0 [60.4] 49.6 [4.9] 2.2 20.8 [59.] 47.8 [4.] 2.7 97. [57.8] 45.7 [42.7].4 92.5 [56.4] 4.5 [42.] 4.0 87.4 [54.9] 4. [4.4] 4.8 8.9 [5.] 8.4 [40.6] 5.6 76.2 [5.6] 5.6 [9.8] 6.4 70. [49.9] 2.6 [8.9] 7. 6.7 [48.0] 29.4 [7.9] 8.2 99.0 [58.] 0.2 [8.2] 2.0 95.0 [57.] 28.7 [7.7] 2.5 90.7 [55.9] 27.0 [7.2]. 86.0 [54.5] 25. [6.7].8 8.0 [5.0] 2.0 [6.] 4.5 75.8 [5.5] 20.8 [5.4] 5. 70.2 [49.9] 8. [4.7] 6. 64. [48.2] 5.8 [.9] 7.0 58. [46.].0 [.] 7.9 206. [60.5] 9.4 [56.7] 2.2 202.0 [59.2] 9. [56.] 2.8 97. [57.8] 88.8 [55.].5 92. [56.4] 86.2 [54.6] 4.2 87.0 [54.8] 8. [5.7] 4.9 8. [5.] 80. [52.8] 5.7 75. [5.4] 75. [5.4] 6.5 69.0 [49.5] 69.0 [49.5] 7.5 62. [47.6] 62. [47.6] 8.4 98.4 [58.] 67.5 [49.] 2.0 94.2 [56.9] 65.7 [48.6] 2.6 89.7 [55.6] 6.6 [48.0].2 84.9 [54.2] 6.4 [47.].9 79.8 [52.7] 59.0 [46.6] 4.6 74. [5.] 56. [45.8] 5.4 68.5 [49.4] 5.4 [45.0] 6.2 62.5 [47.6] 50.5 [44.] 7. 56.0 [45.7] 47.2 [4.2] 8. 9.7 [56.2] 46.8 [4.0].8 87.6 [55.0] 45. [42.6] 2.4 8. [5.7] 4.5 [42.].0 78.6 [52.] 4.6 [4.5].7 7.7 [50.9] 9.6 [40.9] 4.4 68.4 [49.4] 7. [40.2] 5. 62.8 [47.7] 4.8 [9.5] 6.0 56.9 [46.0] 2. [8.8] 6.8 50.8 [44.2] 29.6 [8.0] 7.8 ENTERING INDOOR AIR @ 80 F [26.7 C] dbe ➀ wbe 7 F [2.7 C] 67 F [9.4 C] 6 F [7.2 C] CFM [L/s] 8400 [964] 7025 [5] 5600 [264] 8400 [964] 7025 [5] 5600 [264] 8400 [964] 7025 [5] 5600 [264] DR ➀.06.09..06.09..06.09. 258.4 [75.7] 9.9 [56.8].0 252.7 [74.] 82. [5.4].6 246.7 [72.] 7.9 [50.4] 4.2 240.4 [70.5] 62.9 [47.8] 4.9 2.8 [68.5] 55. [45.5] 5.7 226.9 [66.5] 49.0 [4.7] 6.5 29.7 [64.4] 4.9 [42.2] 7. 22.2 [62.2] 40. [4.] 8.2 204.4 [59.9] 8. [40.5] 9. 249.5 [7.] 68.8 [49.5] 2.8 244.0 [7.5] 58. [46.4].4 28.2 [69.8] 49.0 [4.7] 4.0 22. [68.0] 4.0 [4.] 4.7 225.7 [66.] 4.2 [9.] 5.4 29. [64.2] 28.7 [7.7] 6.2 22. [62.2] 24. [6.4] 7.0 204.9 [60.] 2. [5.6] 7.9 97. [57.8] 9.4 [5.0] 8.8 240. [70.4] 44.5 [42.4] 2.5 25.0 [68.9] 5.2 [9.6]. 229.4 [67.2] 26.9 [7.2].7 22.5 [65.5] 9.9 [5.] 4.4 27.4 [6.7] 4.0 [.4] 5. 2.0 [6.8] 09.2 [2.0] 5.9 204. [59.9] 05.5 [0.9] 6.7 97. [57.8] 02.9 [0.2] 7.5 90. [55.7] 0.6 [29.8] 8.5 244. [7.5] 224.6 [65.8] 2.8 28.4 [69.9] 22.9 [62.4].4 22.4 [68.] 202.7 [59.4] 4. 226. [66.] 9.6 [56.7] 4.8 29.5 [64.] 86.0 [54.5] 5.5 22.6 [62.] 79.6 [52.6] 6. 205.4 [60.2] 74.6 [5.2] 7. 97.9 [58.0] 7.0 [50.] 8.0 90. [55.7] 68.7 [49.5] 9.0 25.7 [69.] 97.4 [57.9] 2.6 20.2 [67.5] 86.9 [54.8].2 224.4 [65.8] 77.7 [52.].8 28. [64.0] 69.6 [49.7] 4.5 22.0 [62.] 62.9 [47.8] 5.2 205. [60.2] 57. [46.] 6.0 98. [58.] 52.9 [44.8] 6.8 9. [56.0] 49.9 [4.9] 7.7 8.5 [5.8] 48.0 [4.4] 8.6 227.0 [66.5] 70.8 [50.] 2.4 22.7 [65.0] 6.5 [47.].0 26. [6.] 5.4 [45.0].6 20. [6.6] 46. [42.9] 4. 204. [59.8] 40. [4.] 5.0 97.7 [57.9] 5.5 [9.7] 5.7 9.0 [56.0].8 [8.6] 6.5 84.0 [5.9] 29. [7.9] 7.4 76.8 [5.8] 27.9 [7.5] 8. 2.9 [68.0] 2.9 [68.0] 2.7 226.2 [66.] 226.2 [66.]. 220.2 [64.5] 220.2 [64.5].9 2.9 [62.7] 2.9 [62.7] 4.6 207. [60.8] 207.0 [60.7] 5. 200.4 [58.7] 200.4 [58.7] 6. 9.2 [56.6] 9.2 [56.6] 7.0 85.7 [54.4] 85.7 [54.4] 7.9 77.9 [52.] 77.9 [52.] 8.8 22.9 [65.6] 27. [6.6] 2.4 28.4 [64.0] 206.6 [60.6].0 22.6 [62.] 97.4 [57.9].7 206.5 [60.5] 89. [55.5] 4.4 200.2 [58.7] 82.6 [5.5] 5. 9.5 [56.7] 77.0 [5.9] 5.9 86.5 [54.7] 72.7 [50.6] 6.7 79. [52.5] 69.6 [49.7] 7.6 7.8 [50.] 67.8 [49.2] 8.5 25.7 [6.2] 89. [55.4] 2.2 20.4 [6.7] 79.8 [52.7] 2.8 204.8 [60.0] 7.7 [50.].4 98.9 [58.] 64.5 [48.2] 4. 92.8 [56.5] 58.6 [46.5] 4.8 86.4 [54.6] 5.8 [45.] 5.6 79.7 [52.7] 50.2 [44.0] 6.4 72.7 [50.6] 47.6 [4.] 7.2 65.4 [48.5] 46. [42.8] 8. NOTES: ➀ When the entering air dry bulb is other than 80 F [27 C], adjust the sensible capacity from the table by adding [.0 x CFM x ( DR) x (dbe 80)].

Gross Systems Performance Data GROSS SYSTEMS PERFORMANCE DATA B240 O UT D O O R D R Y B U LB T E M PE R AT U R E F [ C] 75 [2.9] 80 [26.7] 85 [29.4] 90 [2.2] 95 [5] 00 [7.8] 05 [40.6] 0 [4.] 5 [46.] ENTERING INDOOR AIR @ 80 F [26.7 C] dbe ➀ wbe 7 F [2.7 C] 67 F [9.4 C] 6 F [7.2 C] CFM [L/s] 9600 [45] 7725 [646] 6400 [020] 9600 [45] 7725 [646] 6400 [020] 9600 [45] 7725 [646] 6400 [020] DR ➀.06..5.06..5.06..5 28.5 [8.] 87.4 [54.9] 5.4 280.8 [82.] 86.4 [54.6] 6.2 277.4 [8.] 84.9 [54.2] 7.0 27. [80.0] 82.8 [5.6] 7.9 268. [78.6] 80.2 [52.8] 8.8 262.2 [76.8] 77. [5.9] 9.8 255.5 [74.9] 7.4 [50.8] 20.8 248.0 [72.7] 69.2 [49.6] 2.9 29.6 [70.2] 64. [48.2] 2. 27.5 [79.6] 56. [45.8] 5. 269.0 [78.8] 55.6 [45.6] 5.9 265.7 [77.9] 54.4 [45.] 6.7 26.6 [76.7] 52.7 [44.8] 7.5 256.7 [75.2] 50.5 [44.] 8.4 25. [7.6] 48.0 [4.4] 9.4 244.7 [7.7] 45.0 [42.5] 20.4 27.5 [69.6] 4.5 [4.5] 2.5 229.5 [67.] 7.5 [40.] 22.6 26.0 [77.] 6.0 [9.9] 4.9 260.6 [76.4] 5.4 [9.7] 5.6 257.4 [75.4] 4.4 [9.4] 6.4 25.4 [74.] 2.9 [9.0] 7. 248.7 [72.9]. [8.4] 8.2 24. [7.] 29.0 [7.8] 9. 27. [69.5] 26.4 [7.] 20. 20. [67.4] 2.4 [6.2] 2. 222. [65.] 9.9 [5.] 22.2 269.6 [79.0] 220.5 [64.6] 5. 267.0 [78.2] 29.6 [64.4] 6.0 26.5 [77.2] 28. [6.9] 6.9 259. [76.0] 26.2 [6.4] 7.7 254.2 [74.5] 2.5 [62.6] 8.7 248. [72.8] 20.4 [6.7] 9.6 24.6 [70.8] 206.6 [60.6] 20.7 24. [68.6] 202.4 [59.] 2.7 225.8 [66.2] 97.7 [58.0] 22.9 GROSS SYSTEMS PERFORMANCE DATA B00 O UT D O O R D R Y B U LB T E M PE R AT U R E F [ C] 75 [2.9] 80 [26.7] 85 [29.4] 90 [2.2] 95 [5] 00 [7.8] 05 [40.6] 0 [4.] 5 [46.] DR Depression ratio dbe Entering air dry bulb wbe Entering air wet bulb Total Total capacity x 000 BTUH Sens Sensible capacity x 000 BTUH KW input 258.2 [75.7] 86.7 [54.7] 5.0 255.7 [74.9] 86.0 [54.5] 5.7 252.4 [74.0] 84.8 [54.2] 6.5 248. [72.8] 8.2 [5.7] 7.4 24.5 [7.4] 8. [5.] 8. 27.8 [69.7] 78.5 [52.] 9.2 2.4 [67.8] 75.4 [5.4] 20.2 224.2 [65.7] 7.9 [50.4] 2. 26.2 [6.4] 68.0 [49.2] 22.4 250.2 [7.] 64.4 [48.2] 4.7 247.7 [72.6] 6.8 [48.0] 5.5 244.5 [7.7] 62.7 [47.7] 6. 240.6 [70.5] 6.5 [47.] 7. 25.9 [69.] 59.6 [46.8] 8.0 20.4 [67.5] 57.4 [46.] 8.9 224.2 [65.7] 54.7 [45.] 9.9 27.2 [6.7] 5.7 [44.5] 2.0 209.5 [6.4] 48.4 [4.5] 22. 258.7 [75.8] 245.6 [72.0] 5. 256. [75.] 244.7 [7.7] 5.9 252.6 [74.0] 24. [7.] 6.7 248.4 [72.8] 24. [70.7] 7.6 24. [7.] 28.6 [69.9] 8.5 27.4 [69.6] 25. [69.0] 9.5 20.7 [67.6] 20.7 [67.6] 20.5 22.2 [65.4] 22.2 [65.4] 2.6 24.9 [6.0] 24.9 [6.0] 22.7 247.8 [72.6] 209.7 [6.5] 4.8 245. [7.9] 209.0 [6.] 5.5 242.0 [70.9] 207.8 [60.9] 6. 27.9 [69.7] 206. [60.4] 7.2 2.0 [68.] 204.0 [59.8] 8. 227.4 [66.6] 20.4 [59.0] 9. 22.0 [64.8] 98.4 [58.2] 20. 2.8 [62.7] 94.9 [57.] 2. 205.8 [60.] 9.0 [56.0] 22.2 240.0 [70.] 85.7 [54.4] 4.6 27.6 [69.6] 85.2 [54.] 5. 24.4 [68.7] 84.2 [54.0] 6. 20.5 [67.6] 82.8 [5.6] 6.9 225.8 [66.2] 8.0 [5.] 7.8 220. [64.6] 78.7 [52.4] 8.8 24. [62.7] 76.2 [5.6] 9.8 207. [60.7] 7. [50.7] 20.8 99.4 [58.4] 69.8 [49.8] 2.9 ENTERING INDOOR AIR @ 80 F [26.7 C] dbe ➀ wbe 7 F [2.7 C] 67 F [9.4 C] 6 F [7.2 C] CFM [L/s] 2000 [566] 9475 [4472] 8000 [776] 2000 [566] 9475 [4472] 8000 [776] 2000 [566] 9475 [4472] 8000 [776] DR ➀.02.08 0..02.08 0..02.08 0. 76.4 [0.] 25.6 [7.7] 20.8 69.9 [08.4] 248. [72.7] 2.7 62.5 [06.2] 244.2 [7.6] 22.8 54. [0.8] 29.8 [70.] 2.9 45.4 [0.2] 25.2 [68.9] 25.0 5.7 [98.4] 20. [67.5] 26.2 25.2 [95.] 224.9 [65.9] 27.5.9 [92.0] 29. [64.] 28.9 0.8 [88.4] 2.2 [62.5] 0. 59.0 [05.2] 206.4 [60.5] 20. 52.8 [0.4] 20.6 [59.7] 2.2 45.7 [0.] 200.4 [58.7] 22.2 8.0 [99.] 97.0 [57.7] 2. 29.4 [96.5] 9.2 [56.6] 24.4 20.2 [9.8] 89. [55.5] 25.6 0.2 [90.9] 85.0 [54.2] 26.9 299.4 [87.7] 80.5 [52.9] 28.2 287.9 [84.4] 75.7 [5.5] 29.6 48.9 [02.] 82.0 [5.] 20.0 42.8 [00.5] 79.5 [52.6] 2.0 5.9 [98.4] 76.8 [5.8] 2.9 28.4 [96.2] 7.8 [50.9] 2.0 20. [9.8] 70.5 [50.0] 24.. [9.2] 67. [49.0] 25. 0.4 [88.] 6.4 [47.9] 26.5 290.9 [85.] 59.5 [46.8] 27.8 279.7 [82.0] 55. [45.5] 29.2 58.0 [04.9] 294.2 [86.2] 20.5 5.5 [0.0] 290.8 [85.2] 2.4 44. [00.8] 286.8 [84.] 22.5 5.9 [98.4] 282.4 [82.8] 2.6 27.0 [95.8] 277.8 [8.4] 24.7 7. [9.0] 272.9 [80.0] 25.9 06.8 [89.9] 267.5 [78.4] 27.2 295.5 [86.6] 26.9 [76.8] 28.6 28.4 [8.] 255.8 [75.0] 0.0 4.5 [00.] 245.2 [7.9] 20.0 5.2 [98.2] 242. [7.0] 2.0 28.2 [96.2] 29.2 [70.] 22.0 20.4 [9.9] 25.7 [69.] 2.0.9 [9.4] 22.0 [68.0] 24. 02.6 [88.7] 228.0 [66.8] 25. 292.6 [85.8] 22.7 [65.6] 26.6 28.9 [82.6] 29. [64.] 27.9 270.4 [79.2] 24.5 [62.9] 29..8 [97.2] 28.4 [64.0] 9.7 25.7 [95.5] 25.9 [6.] 20.7 8.9 [9.5] 2.2 [62.5] 2.7. [9.2] 20. [6.6] 22.7 0. [88.8] 207.0 [60.7] 2.8 294. [86.2] 20.6 [59.7] 25.0 284. [8.] 99.8 [58.6] 26.2 27.9 [80.] 95.9 [57.4] 27.5 262.7 [77.0] 9.8 [56.2] 28.9 47.0 [0.7] 26.2 [95.6] 20.2 40.4 [99.8] 22.6 [94.6] 2.2.0 [97.6] 8.6 [9.4] 22.2 24.9 [95.2] 4.4 [92.2] 2. 5.9 [92.6] 09.7 [90.8] 24.4 06.2 [89.7] 04.7 [89.] 25.6 295.7 [86.7] 295.7 [86.7] 26.9 284.4 [8.] 284.4 [8.4] 28. 272.4 [79.8] 272.4 [79.8] 29.7 0.9 [97.0] 274.0 [80.] 9.7 24.6 [95.] 27. [79.5] 20.7 7.6 [9.] 268.0 [78.6] 2.7 09.8 [90.8] 264.5 [77.5] 22.7 0. [88.] 260.8 [76.4] 2.9 292. [85.6] 256.9 [75.] 25. 282.0 [82.6] 252.5 [74.0] 26. 27. [79.5] 248. [72.7] 27.6 259.8 [76.] 24. [7.] 29.0 2.6 [94.] 245.5 [72.0] 9.5 5.5 [92.5] 24.0 [7.2] 20.4 08.6 [90.4] 240.2 [70.4] 2.4 0. [88.2] 27.2 [69.5] 22.4 292.8 [85.8] 24.0 [68.6] 2.5 28.8 [8.2] 20.5 [67.6] 24.7 274. [80.] 226.8 [66.5] 25.9 26.6 [77.] 222.9 [65.] 27.2 252.4 [74.0] 28.8 [64.] 28.6 NOTES: ➀ When the entering air dry bulb is other than 80 F [27 C], adjust the sensible capacity from the table by adding [.0 x CFM x ( DR) x (dbe 80)]. Rely on Ruud. 25

Indoor Airflow Performance AIRFLOW PERFORMANCE 5 TON [52.8 kw] SIDEFLOW Air Flow CFM [L/s] Model RKNL-B80 Voltage 208/20,, Phase External Static Pressure Inches of Water [kpa] 0. 0.2 [.05] 0. [.07] 0.4 [.0] 0.5 [.2] 0.6 [.5] 0.7 [.7] 0.8 [.20] 0.9 [.22].0 [.25]. [.27].2 [.0]. [.2].4 [.5].5 [.7].6 [.40].7 [.42].8 [.45].9 [.47] 2.0 [.50] RPM W RPM W RPM W RPM W RPM W RPM W RPM W RPM W RPM W RPM W RPM W RPM W RPM W RPM W RPM W 4800 [2265] 58 9 608 508 62 62 656 72 679 84 70 947 72 2052 744 254 764 2254 785 226 5000 [259] 59 476 66 59 640 707 66 820 686 90 708 208 729 245 750 2248 77 250 79 2420 5200 [2454] 442 600 562 624 68 648 797 67 9 69 202 75 2 76 224 757 246 777 240 797 2520 5400 [2548] 58 50 608 652 62 772 655 890 678 2005 70 29 722 22 74 240 764 2447 784 252 804 2626 5600 [264] 592 62 66 745 640 866 66 986 686 20 708 228 729 2 750 2442 770 255 79 2620 80 279 5800 [277] 576 588 60 75 625 840 649 964 672 2085 694 2204 76 22 77 246 757 2548 778 264 798 275 87 2858 RPM W RPM W RPM W 805 240 825 257 844 2647 8 2528 80 2640 850 2755 87 26 86 2749 855 2869 82 2744 842 2865 86 2989 80 286 849 2987 867 6 86 2985 855 6 87 249 6000 [28] 585 68 60 8 64 940 657 2065 680 287 702 208 724 2426 744 254 765 2657 785 27 805 2856 824 2984 84 6 86 25 879 89 6200 [2926] 570 650 595 78 69 9 64 2042 666 269 688 229 70 245 7 255 752 265 77 2728 792 2854 82 2984 8 6 850 25 868 92 886 55 6400 [020] 579 750 604 885 628 207 652 248 674 2276 697 2402 78 2526 79 2648 760 2767 780 2852 800 298 89 8 88 255 856 96 875 54 892 688 6600 [4] 589 854 64 99 67 225 66 2257 68 286 705 254 727 2640 748 276 768 2884 788 2984 808 9 827 258 845 400 86 546 88 695 899 847 6800 [209] 574 822 599 96 62 2099 647 225 670 269 692 2500 74 2629 75 2756 756 2882 776 2984 796 2 85 262 84 405 85 552 87 702 888 856 905 40 7000 [0] 584 90 609 2072 6 22 656 249 679 2484 70 267 72 2748 744 2877 764 00 785 24 804 265 82 40 842 559 860 70 878 865 895 4024 92 485 7200 [98] 570 897 595 2042 69 285 64 227 666 2466 689 2602 7 277 72 2870 75 000 77 27 79 270 82 46 8 566 849 79 868 875 885 405 902 498 99 464 NOTE: L-Drive left of bold line, M-Drive right of bold line. RPM W RPM W 86 276 88 2878 868 287 887 2995 874 2992 892 8 879 7 897 248 885 248 90 84 89 86 909 527 897 5 94 676 90 682 920 82 909 89 926 994 96 400 922 47 929 450 Drive Package L M Motor H.P. [W].0 [227.] 5.0 [728.5] Blower Sheave BK05H BK05H Motor Sheave VL-44 VP-56 Turns Open 2 4 5 6 2 4 5 6 RPM 7 70 669 640 605 572 927 90 87 840 808 775 NOTES:. Factory sheave settings are shown in bold type. 2. Do not set motor sheave below minimum turns open shown.. Re-adjustment of sheave required to achieve rated airflow at AHRI minimum External Static Pressure. 4. Drive data shown is for horizontal airflow with dry coil. Add component resistance (below) to duct resistance to determine total External Static Pressure. COMPONENT AIR RESISTANCE 5 TON [52.8 kw] CFM [L/s] Wet Coil Downflow Downflow Economizer R.A. Damper Open Horizontal Economizer R.A. Damper Open Concentric Grill RXRN-AD80 or RXRN-AD8 & Transition RXMC-CJ07 4800 [2265] 0.0 [0.0] 0.05 [0.0] 0.09 [0.02] 0.00 [0.00] 0.2 [0.05] 5000 [260] 0.04 [0.0] 0.05 [0.0] 0.0 [0.02] 0.0 [0.00] 0.25 [0.06] 5200 [2454] 0.05 [0.0] 0.05 [0.0] 0.0 [0.02] 0.0 [0.00] 0.28 [0.07] 5400 [2549] 0.06 [0.0] 0.05 [0.0] 0. [0.0] 0.02 [0.00] 0.2 [0.08] 5600 [264] NOTE: Add component resistance to duct resistance to determine total external static pressure. 0.06 [0.0] 0.05 [0.0] 0.2 [0.0] 0.02 [0.00] 0.5 [0.09] 5800 [277] 0.07 [0.02] 0.05 [0.0] 0. [0.0] 0.0 [0.0] 0.9 [0.0] 6000 [282] 0.08 [0.02] 0.05 [0.0] 0. [0.0] 0.0 [0.0] 0.4 [0.] 6200 [2926] Resistance Inches of Water [kpa] 0.09 [0.02] 0.06 [0.0] 0.4 [0.0] 0.04 [0.0] 0.46 [0.] 6400 [020] 0.0 [0.02] 0.06 [0.0] 0.5 [0.04] 0.04 [0.0] 0.50 [0.2] 6600 [5] 0.0 [0.02] 0.06 [0.0] 0.6 [0.04] 0.05 [0.0] 0.54 [0.] 6800 [209] 0. [0.0] 0.07 [0.02] 0.6 [0.04] 0.05 [0.0] 0.57 [0.4] 7000 [04] 0.2 [0.0] 0.08 [0.02] 0.7 [0.04] 0.06 [0.0] 0.6 [0.5] 7200 [98] 0. [0.0] 0.08 [0.02] 0.8 [0.04] 0.06 [0.0] 0.64 [0.6] AIRFLOW CORRECTION FACTORS 5 TON [52.8 kw] ACTUAL CFM [L/s] TOTAL MBTUH 4800 [2265] 0.97 SENSIBLE MBTUH 0.87 5000 [260] 0.97 0.98 0.98 0.90 POWER kw 0.98 0.98 0.99 0.99 0.99.00 5200 [2454] 0.92 5400 [2549] 0.94 5600 [264] 0.99 0.97 5800 [277].00.00.0 0.99 NOTES: Multiply correction factor times gross performance data resulting sensible capacity cannot exceed total capacity. 6000 [282].02.00 6200 [2926].04.00 6400 [020].02.06.0 6600 [5].02.09.0 6800 [209].0..0 7000 [04].0.4.02 7200 [98].04.6.02 26 Rely on Ruud.

Indoor Airflow Performance AIRFLOW PERFORMANCE 7.5 TON [6.5 kw] SIDEFLOW Air Flow CFM [L/s] Model RKNL-B20 Voltage 208/20,, Phase External Static Pressure Inches of Water [kpa] 0. 0.2 [.05] 0. [.07] 0.4 [.0] 0.5 [.2] 0.6 [.5] 0.7 [.7] 0.8 [.20] 0.9 [.22].0 [.25]. [.27].2 [.0]. [.2].4 [.5].5 [.7].6 [.40].7 [.42].8 [.45].9 [.47] 2.0 [.50] RPM W RPM W RPM W RPM W RPM W RPM W RPM W RPM W RPM W RPM W RPM W RPM W RPM W RPM W RPM W 5600 [264] 599 627 625 762 65 900 676 2042 70 286 725 24 749 2484 77 268 796 2795 89 2955 84 9 86 285 5800 [277] 60 79 65 856 66 996 685 240 70 2286 74 246 757 2588 780 2744 80 290 825 065 847 20 869 99 6000 [28] 62 822 646 96 67 20 695 2248 79 297 742 2548 765 270 788 2860 80 02 82 85 854 5 875 52 6200 [2926] 607 797 62 95 657 2076 68 2220 705 267 728 257 75 267 774 2827 796 2987 88 50 840 6 86 485 88 657 6400 [020] 69 99 644 2058 668 220 692 247 75 2496 78 2649 76 2804 78 2962 805 24 826 289 847 457 868 628 888 802 6600 [4] 607 92 62 205 656 292 679 27 70 2485 726 266 748 2790 770 2947 792 08 8 272 84 48 855 608 875 78 895 957 RPM W RPM W RPM W 885 455 906 628 927 80 890 570 9 745 9 92 896 696 96 87 96 405 902 8 92 40 94 49 908 980 927 94 47 9 49 RPM W RPM W 6800 [209] 620 2052 644 29 668 26 69 248 74 26 77 2786 759 2942 780 0 802 264 822 429 84 598 86 770 88 945 902 42 92 404 940 4489 7000 [0] 60 2064 64 220 657 245 68 249 70 2640 726 279 748 2946 769 04 79 266 8 40 82 598 852 768 87 942 89 49 90 4299 928 4482 7200 [98] 624 222 648 264 67 2508 69 2656 76 2807 78 2960 759 7 780 277 80 440 822 607 84 776 86 949 880 424 899 40 97 4485 96 4670 7400 [492] 69 292 662 256 684 2682 707 28 728 2984 750 9 77 298 792 82 625 82 794 85 965 87 49 889 47 908 4498 926 4682 7600 [586] 65 2572 676 277 698 2866 720 07 742 7 76 29 78 490 80 654 82 82 84 99 862 464 88 44 899 4520 97 470 94 4889 7800 [68] 669 2762 69 290 7 060 74 2 755 69 775 529 796 692 85 857 85 4026 854 499 872 474 89 4552 909 474 926 498 8000 [775] 684 296 706 2 727 264 748 49 769 578 789 79 808 904 828 4072 847 424 865 447 88 4594 90 4774 99 4958 96 544 8200 [869] 700 74 72 25 742 479 762 66 78 796 802 960 82 427 840 4296 859 4469 877 4645 895 4824 92 5007 929 592 8400 [964] 76 95 77 548 757 704 777 86 797 4026 86 49 85 459 85 45 87 4706 889 4884 906 5065 92 5249 940 547 NOTE: L-Drive left of bold line, M-Drive right of bold line. Drive Package L M Motor H.P. [W].0 [227.] 5.0 [728.5] Blower Sheave BK00H BK05H Motor Sheave VL-44 VP-56 Turns Open 2 4 5 6 2 4 5 6 RPM 76 7 699 666 6 60 99 909 879 845 84 78 NOTES:. Factory sheave settings are shown in bold type. 2. Do not set motor sheave below minimum turns open shown.. Re-adjustment of sheave required to achieve rated airflow at AHRI minimum External Static Pressure. 4. Drive data shown is for horizontal airflow with dry coil. Add component resistance (below) to duct resistance to determine total External Static Pressure. COMPONENT AIR RESISTANCE 7.5 TON [6.5 kw] CFM [L/s] Wet Coil Downflow Downflow Economizer R.A. Damper Open Horizontal Economizer R.A. Damper Open Concentric Grill RXRN-AD80 or RXRN-AD8 & Transition RXMC-CJ07 Concentric Grill RXRN-AD86 & Transition RXMC-CK08 AIRFLOW CORRECTION FACTORS 7.5 TON [6.5 kw] ACTUAL CFM [L/s] TOTAL MBH 5600 [264] 0.96 SENSIBLE MBH 0.86 5600 [264] 0.06 [.0] 0.05 [.0] 0.2 [.0] 0.02 [.00] 0.5 [.09] 0.4 [.0] 5800 [277] 6200 [2926] 0.97 0.97 0.98 0.88 5800 [277] 0.07 0.05 [.0] 0. [.0] 0.0 [.0] 0.9 [.0] 0.7 [.04] 6000 [28] 6000 [28] POWER kw 0.99 0.99 0.99 0.99.00.00 0.08 0.05 [.0] 0. [.0] 0.0 [.0] 0.4 [.] 0.20 [.05] 0.90 6200 [2926] 0.09 0.06 [.0] 0.4 [.0] 0.04 [.0] 0.46 [.] 0.2 [.06] 6400 [020] 0.92 0.0 0.06 [.0] 0.5 [.04] 0.04 [.0] 0.50 [.] 0.26 [.06] 6600 [4] 0.0 0.06 [.0] 0.6 [.04] 0.05 [.0] 0.54 [.] 0.29 [.07] 6400 [020] 0.98 0.94 6800 [209] 0. [.0] 0.07 0.6 [.04] 0.05 [.0] 0.57 [.4] 0.2 [.08] 7000 [0] 0.2 [.0] 0.08 0.7 [.04] 0.06 [.0] 0.6 [.5] 0.5 [.09] 6600 [4] 0.99 0.99.00 0.96 7200 [98] 0. [.0] 0.08 0.8 [.04] 0.06 [.0] 0.64 [.6] 0.8 [.09] 6800 [209] 0.98.00 NOTES: Multiply correction factor times gross performance data resulting sensible capacity cannot exceed total capacity. 7400 [492] Resistance Inches of Water [kpa] 0.4 [.0] 0.09 0.9 [.05] 0.07 0.68 [.7] 0.4 [.0] 7600 [586] 0.4 [.0] 0.0 0.20 [.05] 0.07 0.72 [.8] 0.44 [.] 7000 [0].00.00 7800 [68] 0.5 [.04] 0. [.0] 0.2 [.05] 0.08 0.75 [.9] 0.47 [.2] 8000 [775] 7200 [98].00.02.0 0.6 [.04] 0.2 [.0] 0.22 [.05] 0.09 0.79 [.20] 0.50 [.2] 8200 [869] 0.7 [.04] 0. [.0] 0.2 [.06] 0.09 0.8 [.2] 0.5 [.] 7400 [492].0.04.0 8400 [964] 0.8 [.04] 0.4 [.0] 0.24 [.06] 0.0 0.86 [.2] 0.56 [.4] 7600 [586].0.06.0 7800 [68].02.08.0 8000 [775].0.0.02 8200 [869].0.2.02 8400 [964].04.4.02 Rely on Ruud. 27

Indoor Airflow Performance AIRFLOW PERFORMANCE 20 TON [70. kw] SIDEFLOW Air Flow CFM [L/s] Model RKNL-B240 Voltage 208/20,, Phase External Static Pressure Inches of Water [kpa] 0. 0.2 [.05] 0. [.07] 0.4 [.0] 0.5 [.2] 0.6 [.5] 0.7 [.7] 0.8 [.20] 0.9 [.22].0 [.25]. [.27].2 [.0]. [.2].4 [.5].5 [.7].6 [.40].7 [.42].8 [.45].9 [.47] 2.0 [.50] RPM W RPM W RPM W RPM W RPM W RPM W RPM W RPM W RPM W RPM W RPM W RPM W RPM W RPM W RPM W 6400 [020] 62 2007 654 2 676 228 698 228 79 249 74 255 76 2670 785 2789 80 065 80 20 850 42 6600 [5] 642 206 664 227 686 20 707 2446 729 2564 75 2685 77 2808 798 060 89 20 88 42 857 484 6800 [209] 60 200 652 225 674 22 696 2452 78 2574 79 2699 76 2826 78 2955 807 202 827 46 846 490 865 64 7000 [04] 64 22 66 24 684 2458 706 2585 728 27 750 2844 772 2977 796 207 86 52 85 499 854 646 87 794 7200 [98] 60 22 65 26 67 2464 695 2594 77 2727 79 2862 76 2999 78 9 805 62 825 5 844 66 86 8 88 96 7400 [492] 64 28 66 2470 684 2604 706 274 728 2880 750 02 772 65 795 75 85 526 84 678 85 8 87 984 889 47 RPM W RPM W RPM W 869 48 888 62 906 76 876 626 894 769 92 92 884 780 90 926 99 4072 89 942 909 409 926 4240 898 42 96 4264 92 447 906 4292 92 4447 98 4650 RPM W RPM W 92 902 97 42 90 4056 944 427 9 428 950 442 940 4448 957 947 4624 964 4784 954 480 97 4976 7600 [587] 60 29 652 2475 674 26 696 2754 78 2897 740 04 76 90 78 4 805 545 824 699 84 854 862 4009 879 465 897 422 94 4479 90 467 945 484 962 5007 978 579 7800 [68] 642 2480 664 2622 686 2767 707 294 729 064 75 26 77 70 795 567 85 72 84 880 852 408 870 497 888 456 905 455 922 4675 96 4878 95 504 969 524 986 592 8000 [776] 62 2485 654 26 676 2780 698 29 79 085 74 24 76 99 785 559 806 750 825 90 844 4070 862 42 880 492 897 4554 94 477 90 4880 944 5084 96 5255 977 542 99 566 8200 [870] 644 2640 666 279 688 2948 70 05 72 265 754 427 776 592 797 780 86 942 85 405 854 4268 87 442 889 4596 906 476 922 4927 96 50 952 500 969 5477 985 5660 00 5850 8400 [964] 657 2805 679 2964 70 26 72 290 745 456 767 625 789 796 808 978 827 44 846 409 864 4475 88 4642 898 4809 95 4977 9 546 944 552 96 5528 977 570 99 5899 008 6094 8600 [4059] 670 2980 692 46 74 4 76 484 758 657 780 82 800 407 89 484 88 452 856 452 874 4690 89 4860 907 500 924 520 97 5408 95 5584 969 5765 985 5954 00 648 8800 [45] 68 66 705 8 727 52 749 689 77 868 79 4059 82 4229 8 499 849 4570 867 4742 884 494 90 5087 97 5260 9 544 946 5645 962 5826 978 60 99 6208 009 6408 9000 [4248] 697 6 79 540 74 72 76 904 785 4089 805 4276 824 4449 842 4622 860 4796 877 497 894 546 9 522 927 5498 99 572 955 5892 97 6079 986 6272 002 6472 9200 [442] 7 567 7 752 755 99 777 429 798 427 87 4502 85 4678 85 4854 87 50 888 5209 905 587 92 5565 9 5784 949 596 964 649 980 642 995 654 00 6747 9400 [446] 725 78 747 975 769 468 792 48 8 4558 829 476 847 495 865 5094 882 5274 899 5455 95 566 9 588 942 6040 958 6225 97 648 989 666 004 682 9600 [45] 79 400 762 4207 784 4407 805 467 82 4798 842 4979 859 56 877 54 894 5526 90 5709 926 5894 97 622 952 607 968 6498 98 6696 998 690 NOTE: L-Drive left of bold line, M-Drive right of bold line. Drive Package L M Motor H.P. [W] 5.0 [728.5] 7.5 [5592.7] Blower Sheave BK0H BK0H Motor Sheave VP-56 VP-7 Turns Open 2 4 5 6 2 4 5 6 RPM 756 74 709 68 658 6 928 902 874 847 820 79 NOTES:. Factory sheave settings are shown in bold type. 2. Do not set motor sheave below minimum turns open shown. N (field installed only) 7.5 [5592.7] BK20H VP-7 2 4 5 6 009 98 955 928 899 870. Re-adjustment of sheave required to achieve rated airflow at AHRI minimum External Static Pressure. 4. Drive data shown is for horizontal airflow with dry coil. Add component resistance (below) to duct resistance to determine total External Static Pressure. COMPONENT AIRFLOW RESISTANCE 20 TON [70. kw] CFM [L/s] Wet Coil Downflow Downflow Economizer R.A. Damper Open Horizontal Economizer R.A. Damper Open Concentric Grill RXRN-AD86 & Transition RXMC-CK08 6400 [020] 0.00 [.00] 0.06 [.0] 0.5 [.04] 0.04 [.0] 0.26 [.06] 6600 [4] 0.00 [.00] 0.06 [.0] 0.6 [.04] 0.05 [.0] 0.29 [.07] 6800 [209] 0.00 [.00] 0.07 0.6 [.04] 0.05 [.0] 0.2 [.08] 7000 [0] 0.0 [.00] 0.08 0.7 [.04] 0.06 [.0] 0.5 [.09] 7200 [98] 0.0 [.00] 0.08 0.8 [.04] 0.06 [.0] 0.8 [.09] 7400 [492] 0.02 [.00] 0.09 0.9 [.05] 0.07 0.4 [.0] 7600 [586] Resistance Inches of Water [kpa] AIRFLOW CORRECTION FACTORS 20 TON [70. kw] ACTUAL CFM [L/s] 6400 [020] 6600 [4] 6800 [209] 7000 [0] 7200 [98] 0.02 [.00] 0.0 0.20 [.05] 0.07 0.44 [.] 7800 [68] 0.0 [.0] 0. [.0] 0.2 [.05] 0.08 0.47 [.2] 7400 [492] 8000 [775] 0.0 [.0] 0.2 [.0] 0.22 [.05] 0.09 0.5 [.2] 7600 [586] 8200 [869] 0.04 [.0] 0. [.0] 0.2 [.06] 0.09 0.5 [.] TOTAL MBH 0.97 0.97 0.98 0.98 0.99 0.99.00.00.0.0.02.02.0.0.0.04 SENSIBLE MBH 0.88 0.90 0.92 0.94 0.96 0.97 0.99.0.0.05.07.09.0.2.4.6 POWER kw 0.98 0.99 0.99 0.99 0.99.00.00.00.00.0.0.0.0.0.02.02 8400 [964] 0.04 [.0] 0.4 [.0] 0.24 [.06] 0.0 0.56 [.4] 7800 [68] 8600 [4058] 0.05 [.0] 0.5 [.04] 0.25 [.06] 0.0 0.59 [.5] 8000 [775] 8800 [45] 0.05 [.0] 0.6 [.04] 0.26 [.06] 0. [.0] 0.62 [.5] 9000 [4247] 0.06 [.0] 0.8 [.04] 0.27 [.07] 0. [.0] 0.65 [.6] 8200 [869] 9200 [44] 0.06 [.0] 0.9 [.05] 0.28 [.07] 0.2 [.0] 0.69 [.7] 8400 [964] 9400 [446] 0.07 0.20 [.05] 0.29 [.07] 0.2 [.0] 0.72 [.8] 9600 [450] 0.07 0.22 [.05] 0.0 [.07] 0. [.0] 0.75 [.9] 8600 [4058] 8800 [45] 9000 [4247] 9200 [44] 9400 [446] 9600 [450].04.8.02 NOTES: Multiply correction factor times gross performance data resulting sensible capacity cannot exceed total capacity. 28 Rely on Ruud.

Indoor Airflow Performance AIRFLOW PERFORMANCE 25 TON [87.9 kw] SIDEFLOW Air Flow CFM [L/s] Model RKNL-B00 Voltage 208/20,, Phase External Static Pressure Inches of Water [kpa] 0. 0.2 [.05] 0. [.07] 0.4 [.0] 0.5 [.2] 0.6 [.5] 0.7 [.7] 0.8 [.20] 0.9 [.22].0 [.25]. [.27].2 [.0]. [.2].4 [.5].5 [.7].6 [.40].7 [.42].8 [.45].9 [.47] 2.0 [.50] RPM W RPM W RPM W RPM W RPM W RPM W RPM W RPM W RPM W RPM W RPM W RPM W RPM W RPM W RPM W 8000 [775] 794 720 84 870 8 4024 85 482 869 444 886 450 90 4680 920 4854 8200 [869] 807 908 826 4065 845 4226 86 492 880 456 897 475 94 492 94 5296 8400 [964] 80 947 820 408 88 427 856 4442 874 464 89 479 908 4972 924 557 952 550 8600 [4058] 794 989 8 45 82 42 850 449 868 4670 886 4850 902 504 99 522 947 5557 962 5725 8800 [45] 807 4200 826 47 845 4547 862 4727 880 490 897 5098 9 5290 942 564 957 5787 972 5960 9000 [4247] 80 4249 820 4424 89 857 4786 874 497 892 564 908 559 924 5558 952 585 967 60 982 6209 RPM W RPM W RPM W 948 5256 96 540 979 5565 958 5455 97 564 988 5774 967 5667 982 582 997 5997 977 5894 992 6064 007 625 987 64 002 60 07 6486 997 689 02 6570 027 6752 RPM W RPM W 994 5720 009 5877 00 595 08 6097 02 664 028 6 022 6407 07 6579 02 666 047 684 042 694 057 78 9200 [44] 795 400 85 4478 8 4660 85 4847 869 507 886 522 90 540 99 56 947 592 962 605 977 6289 992 647 007 6658 022 6844 07 70 052 729 068 7408 9400 [446] 790 452 809 454 828 4720 846 490 864 504 88 502 898 5504 95 570 94 5997 958 684 972 672 987 656 002 6750 07 694 02 72 048 725 06 758 9600 [450] 804 4592 82 478 84 4975 859 572 876 57 89 5579 90 5788 926 6002 95 6267 968 6 98 665 998 6847 0 7042 028 728 04 744 058 762 9800 [4624] 798 4652 87 4845 86 5042 854 5242 872 5447 889 5656 905 5869 922 6085 949 655 964 655 979 6749 994 6947 009 747 024 747 09 7548 054 775 069 7954 0000 [479] 79 474 8 490 8 50 849 55 867 552 884 90 595 97 67 945 6446 960 6647 975 6849 990 7052 005 7256 09 746 04 7667 050 787 065 808 0200 [48] 808 4978 827 58 845 589 86 5600 880 586 897 605 9 6259 94 6542 956 6748 97 6954 986 762 00 770 06 7579 0 7789 046 8000 06 822 0400 [4908] 822 5254 840 5465 858 5680 876 5899 89 622 909 649 926 6580 95 6852 967 706 982 7275 997 7488 02 770 027 796 042 8 057 848 072 8565 0600 [5002] 86 554 854 576 872 5984 889 620 906 644 922 6675 949 696 964 776 979 79 99 760 008 7828 02 8047 08 8267 05 8488 068 870 0800 [5096] 850 5845 868 607 885 60 902 654 98 6772 946 7074 96 7294 975 754 990 776 005 7959 020 882 05 8407 050 862 065 8858 000 [59] 864 660 882 69 899 660 95 687 94 79 958 745 972 7640 987 7867 002 8094 07 82 02 8550 046 8780 06 90 200 [5285] 878 6487 895 6728 92 6972 940 7 955 754 969 777 984 800 999 82 04 8465 029 8698 04 89 058 968 400 [579] 892 6827 909 7075 925 728 952 767 967 7905 98 840 996 876 0 86 026 885 04 9089 055 929 070 9570 600 [5474] 906 780 922 746 950 7806 964 8044 979 828 994 8524 008 8765 02 9007 08 9250 05 9494 068 979 800 [5568] 920 7546 948 7944 962 887 977 84 99 8676 006 892 02 968 05 946 050 9664 065 99 2000 [566] 946 8087 960 84 975 858 989 882 004 9082 09 9 0 9585 048 988 06 0092 NOTE: L-Drive left of bold line, M-Drive right of bold line. Drive Package L M Motor H.P. [W] 7.5 [5592.7] 0 [7457.0] Blower Sheave BK0H BK20H Motor Sheave VP-7 VP-75 Turns Open 2 4 5 6 2 4 5 6 RPM 99 894 869 844 87 790 067 09 02 982 95 925 NOTES:. Factory sheave settings are shown in bold type. 2. Do not set motor sheave below minimum turns open shown.. Re-adjustment of sheave required to achieve rated airflow at AHRI minimum External Static Pressure. 4. Drive data shown is for horizontal airflow with dry coil. Add component resistance (below) to duct resistance to determine total External Static Pressure. COMPONENT AIR RESISTANCE 25 TON [87.9 kw] CFM [L/s] Wet Coil Downflow Downflow Economizer R.A. Damper Open Horizontal Economizer R.A. Damper Open Concentric Grill RXRN-AD88 & Transition RXMC-CL09 8000 [775] 0.07 0.2 [.0] 0.22 [.05] 0.09 0.7 [.04] 8400 [964] 0.09 0.4 [.0] 0.24 [.06] 0.0 0.2 [.06] 8800 [45] 0.0 0.6 [.04] 0.26 [.06] 0. [.0] 0.0 [.07] 9200 [44] 0.2 [.0] 0.9 [.05] 0.28 [.07] 0.2 [.0] 0.6 [.09] 9600 [450] 0. [.07] 0. [.0] 0.4 [.] 0.25 [.06] 0.2 [.08] 0.4 [.0] 0.50 [.2] 0400 [4908] Resistance Inches of Water [kpa] 0. [.0] 0.22 [.05] 0000 [479] 0.5 [.04] 0.6 [.04] 0.29 [.07] 0.4 [.08] 0.5 [.04] 0.56 [.4] 0800 [5096] 0.8 [.04] 0. [.08] 0.7 [.09] 0.6 [.04] 0.6 [.6] 200 [5285] 0.9 [.05] 0.7 [.09] 0.9 [.0] 0.7 [.04] 0.69 [.7] 600 [5474] 0.2 [.05] 0.42 [.0] 0.4 [.0] 0.8 [.04] 0.76 [.9] 2000 [566] 0.22 [.05] 0.46 [.] 0.44 [.] 0.9 [.05] 0.82 [.20] AIRFLOW CORRECTION FACTORS 25 TON [87.9 kw] ACTUAL CFM [L/s] TOTAL MBTUH SENSIBLE MBTUH 8000 [775] 0.97 0.89 8400 [964] 8800 [45] 0.98 0.99 0.99 0.92 0.95 0.98 POWER kw 0.99 0.99.00.00.00.0 NOTES: Multiply correction factor times gross performance data resulting sensible capacity cannot exceed total capacity. 9200 [44] 9600 [450].00.0 0000 [479] 0800 [5096].0.02.0.04 0400 [4908].08.0..0 200 [5285].0.4.02 600 [5474].04.7.02 2000 [566].05.20.02 Rely on Ruud. 29

Electrical Data ELECTRICAL DATA RKNL-B SERIES B80CL B80CM B80DL B80DM B80YL B80YM B20CL B20CM B20DL Unit Operating Voltage Range 87-25 87-25 44-506 44-506 58-62 58-62 87-25 87-25 44-506 Evaporator Fan Condenser Motor Compressor Motor Unit Information Volts Minimum Overcurrent Protection Device Size Maximum Overcurrent Protection Device Size 208/20 90/90 00/00 No. 2 Volts 200/20 Phase RPM 450 HP, Compressor 7 Amps (LRA), Comp. 64/64 Amps (RLA), Comp. 2 25/25 No. 4 Volts 208/20 Phase HP / Amps (FLA, each) 2.4/2.4 Amps (LRA, each) 4.7/4.7 No. Volts 208/20 Phase HP 208/20 90/90 00/00 200/20 450 64/64 25/25 208/20 / 2.4/2.4 4.7/4.7 208/20 Amps (FLA, each).5/.5 4.9/4.9 2 7 4 5 45 45 2 450 7 00 2.2 4 /.4 2.4 4.6 0 5 2 450 7 78 9 4 /.8.5 208/20 00/00 0/0 2 200/20 450 7 /2 95/95 29.5/29.5 4 208/20 / 2.4/2.4 4.7/4.7 208/20.5/.5 208/20 Minimum Circuit Ampacity 78/78 8/8 8 40 28 0 88/88 9/9 44 00/00 0/0 200/20 Amps (RLA), Comp. 25/25 25/25 2.2 2.2 9 9 29.5/29.5 29.5/29.5 4.7 95/95 HP, Compressor 2 7 7 7 7 7 7 7 /2 7 /2 7 /2 29.5/29.5 Amps (LRA), Comp. 2 64/64 64/64 00 00 78 78 95/95 95/95 95 208/20 208/20 4.9/4.9 Amps (LRA, each) 74.5/74.5 82.6/82.6 8. 46. 20 9.4 74.5/74.5 82.6/82.6 8. 45 50 2 450 7 00 2.2 4 /.4 2.4 5 6.6 5 5 2 450 7 78 9 4 /.8 5 5. 2 450 7 /2 4 / 2.4/2.4 4.7/4.7 5 50 50 2 450 7 /2 95 4.7 4 /.4 2.4 4.6 0 Rely on Ruud.

Electrical Data ELECTRICAL DATA RKNL-B SERIES B20DM B20YL B20YM B240CL B240CM B240CN B240DL B240DM B240DN Unit Operating Voltage Range 44-506 58-62 58-62 87-25 87-25 87-25 44-506 44-506 44-506 Evaporator Fan Condenser Motor Compressor Motor Unit Information Volts Minimum Overcurrent Protection Device Size Maximum Overcurrent Protection Device Size Amps (LRA, each) 46. 20 9.4 50 50 No. 2 Volts Phase RPM 450 HP, Compressor 7 /2 Amps (LRA), Comp. 95 Amps (RLA), Comp. 2 4.7 No. 4 Volts Phase HP / Amps (FLA, each).4 Amps (LRA, each) 2.4 No. Volts Phase HP 5 450 7 /2 2.2 /.8 Amps (FLA, each) 6.6.5 40 45 2 80 4 40 45 2 450 7 /2 80 2.2 4 /.8 5 5. 208/20 208/20 25/25 25/25 2 200/20 450 0 29/29 29.5/29.5 6 208/20 / 2.4/2.4 4.7/4.7 208/20 7 /2 2./2. 6/6 208/20 Minimum Circuit Ampacity 46 5 7 0/0 09/09 09/09 52 56 56 0/0 25/25 200/20 25/25 25/25 200/20 Amps (RLA), Comp. 4.7 2.2 2.2./../../. 7.9 7.9 7.9 29/29 29/29 HP, Compressor 2 7 /2 7 /2 7 /2 7 /2 7 /2 7 /2 7 /2 7 /2 7 /2 29.5/29.5 29.5/29.5 Amps (LRA), Comp. 2 95 80 80 95/95 95/95 95/95 95 95 95 2 450 0 6 208/20 / 2.4/2.4 4.7/4.7 208/20 5 4.7/4.7 82.6/82.6 2 450 0 6 208/20 / 2.4/2.4 4.7/4.7 208/20 7 /2 2./2. 6/6 60 60 2 450 0 25 4.7 6 /.4 2.4 5 6.6 46. 60 70 2 450 0 25 4.7 6 /.4 2.4 7 /2 9.6 67 60 70 2 450 0 25 4.7 6 /.4 2.4 7 /2 9.6 67 Rely on Ruud.

Electrical Data ELECTRICAL DATA RKNL-B SERIES B240YL B240YM B240YN B00CL B00CM B00DL B00DM B00YL B00YM Unit Operating Voltage Range 58-62 58-62 58-62 87-25 87-25 44-506 44-506 58-62 58-62 Evaporator Fan Condenser Motor Compressor Motor Unit Information Volts Minimum Overcurrent Protection Device Size Maximum Overcurrent Protection Device Size Amps (LRA, each) 9.4 5.8 5.8 45 50 No. 2 Volts Phase RPM 450 HP, Compressor 0 Amps (LRA), Comp. 80 Amps (RLA), Comp. 2 2.2 No. 6 Volts Phase HP / Amps (FLA, each) Amps (LRA, each).8 No. Volts Phase HP 5 450 2.2 /.8 7 /2 Amps (FLA, each) 5. 7.8 50 50 2 0 80 6 50 50 2 450 0 80 2.2 6 /.8 7 /2 7.8 208/20 208/20 Minimum Circuit Ampacity 40 42 42 47/47 49/49 60 6 47 50 75/75 75/75 200/240 75/75 75/75 2 200/240 Amps (RLA), Comp. 2.8 2.8 2.8 48./48. 48./48. 8.6 8.6 4.7 4.7 245/245 450 /2 245/245 HP, Compressor 2 7 /2 7 /2 7 /2 /2 /2 /2 /2 /2 /2 48./48. 48./48. Amps (LRA), Comp. 2 80 80 80 245/245 245/245 25 25 00 00 2 450 /2 6 208/20 / 2.4/2.4 4.7/4.7 208/20 7 /2 24.2/24.2 6/6 6 208/20 / 2/2.9/.9 208/20 0 28.5/28.5 78/78 70 70 2 450 /2 25 8.6 6 /.4 2.4 7 /2 9.6 67 70 80 2 450 /2 25 8.6 6 /.4 2.4 0 2.5 74.6 60 60 2 450 /2 00 4.7 6 /.8 7 /2 7.8 5.8 60 60 2 450 /2 00 4.7 6 /.8 0 0 59.2 2 Rely on Ruud.

Dimensional Data GAS HEAT / ELECTRIC COOLING PACKAGE BOTTOM VIEW Rely on Ruud.

Dimensional Data GAS HEAT / ELECTRIC COOLING PACKAGE SUPPLY AND RETURN DIMENSIONS FOR HORIZONTAL APPLICATIONS DUCT SIDE VIEW (REAR) SUPPLY AND RETURN DIMENSIONS FOR DOWNFLOW APPLICATIONS 6 9 /2 [67 mm] 6 7 /2 [66 mm] 25 /2 [78 mm] 52 /4 [867 mm] 85 29 /2 [282 mm] 46 /2 [69 mm] 4 /2 [066 mm] 2 /2 [5 mm] R ET U R N A I R TYP. [76 mm] 20 /2 [057 mm] 25 25 /2 [655 mm] SUPPLY AIR 2 [584 mm] 8 [2058 mm] C O ND E N SE R C O IL 7 9 /2 [85 mm] 4 5 /2 [ mm] 20 /6 [50 mm] 20 5 /6 [52 mm] 2 /6 [52 mm] 2 /8 8 [60 mm] /8 TYP. [968 mm] Illustration ST-A25-09A BOTTOM VIEW 4 Rely on Ruud.

Dimensional Data UNIT DIMENSIONS GAS HEAT / ELECTRIC COOLING PACKAGE WEIGHTS Accessory Economizer Downflow Economizer Horizontal Fresh Air Damper (Manual) Fresh Air Damper (Motorized) Roof Curb 4" Shipping lbs [kg] 55 [70.] 65 [74.80] 5 [2.] 46 [20.87] 70 [77.] Operating lbs [kg] 46 [66.22] 55 [70.] 40 [8.4] 5 [5.88] 64 [74.9] Capacity Tons [kw] Corner Weights by Percentage C D B A 24% 27% 6% 2% 5-25 [52.8-87.9] Corner weights measured at base of unit. Rely on Ruud. 5

Dimensional Data SLAB INSTALLATION CLEARANCES The following minimum clearances are recommended for proper unit performance and serviceability. Recommended Clearance In. [mm] 80 [202] 8 [457] +8 [457] *8 [457] 60 [524] Location AB+C *D E- Front Condenser Coil Duct Side Evaporator End Above *Without Economizer. 48" [29 mm] With Economizer +Without Horizontal Economizer, 42" [067 mm] with Horizontal Economizer 6 Rely on Ruud.

Accessories FIELD INSTALLED ACCESSORY EQUIPMENT Thermostat Dual Enthalpy Kit Accessory Downflow Economizer w/single Enthalpy Downflow Economizer w/smoke Detector Horizontal Economizer w/single Enthalpy Model Number See Thermostat Specification Sheet (T22-00) Installed Weight Lbs. [kg] RXRX-AV02 [.5] [.5] AXRD-RGCM Shipping Weight Lbs. [kg] Carbon Dioxide Sensor (Wall Mount) RXRX-AR02 [.4] 2 [.0] Exhaust (208/20V) RXRX-BGF05C 02 [46.] 69 [.] Factory Installation Available? Manual Fresh Air Damper* AXRF-KFA 6 [27.7] 52 [2.6] No Motorized Kit for Manual Fresh Air Damper* RXRX-AW0 42 [9.] 5 [5.9] No Roofcurb, 4" RXKG-CBH4 No Roofcurb Adapter to RXRK-E56 AXRD-PGCM AXRD-SGCM Exhaust (V) RXRX-BGF05D 02 [46.] 69 [.] No Exhaust (V) RXRX-BGF05Y 02 [46.] 69 [.] No Roofcurb Adapter to RXKG-CAF4 RXRX-CJCE56 RXRX-CJCF4 Concentric Diffuser (Step-Down, 8" x 6") RXRN-AD8 0 [40.6] 57 [7.2] No Concentric Diffuser (Step-Down, 24" x 48") RXRN-AD86 67 [66.4] 22 [96.] No Concentric Diffuser (Step-Down, 28" x 60") RXRN-AD88 No Concentric Diffuser (Flush, 8" x 6") RXRN-AD80 2 [96.6] 5 [52.2] No Downflow Transition (Rect. to Rect., 8" x 6") RXMC-CJ07 No Downflow Transition (Rect. to Rect., 24" x 48") RXMC-CK08 No Downflow Transition (Rect. to Rect., 28" x 60") RXMC-CL09 No Low-Ambient Control Kit ( Per Compressor) RXRZ-C02 [.4] 2 [.0] Yes Freeze-Stat Kit RXRX-AM0 [.5] 0.5 [.2] Yes Unwired Convenience Outlet RXRX-AN0 2 [.0].5 [.7] Yes Unfused Service Disconnect+ RXRX-AP0 0 [4.5] 9 [4.] Yes Hail Guard Louvers AXRX-AAD0L 55 [24.8] 45 [20.] Yes *Motorized Kit and Manual Fresh Air Damper must be combined for a complete Motorized Outside Air Damper Selection. +Do not use on RKNL-B240C or RKNL-B00C voltage models. No Yes Yes No No No No No No THERMOSTATS 200-Series * Programmable 00-Series * Deluxe Programmable 400-Series * Special Applications/ Programmable 500-Series * Communicating/ Programmable * Photos are representative. Actual models may vary. For detailed thermostat match-up information, see specification sheet form number T22-00. Rely on Ruud. 7

Accessories ECONOMIZERS Use to Select Factory Installed Options Only AXRD-PGCM Single Enthalpy (Outdoor) AXRD-SGCM Single Enthalpy (Outdoor) with Smoke Detector RXRX-AV02 Dual Enthalpy Upgrade Kit RXRX-AR02 Optional Wall-Mounted CO 2 Sensor Features Honeywell Controls Available Factory Installed or Field Accessory Gear Driven Direct Drive Actuator Fully Modulating (0-00%) Low Leakage Dampers Slip-In Design for Easy Installation Plug-In Polarized 2-pin Electrical Connections Pre-Configured No Field Adjustments Necessary Standard Barometric Relief Damper Single Enthalpy with Dual Enthalpy Upgrade Kit Available CO2 Input Sensor Available Field Assembled Hood Ships with Economizer Economizer Ships Complete for Downflow Duct Application. Optional Remote Minimum Position Potentiometer (Honeywell #S96B28) is Available from Prostock. Field Installed Exhaust Available 8 Rely on Ruud.

Accessories ECONOMIZER FOR HORIZONTAL DUCT INSTALLATION Field Installed Only AXRD-RGCM Single Enthalpy (Outdoor) AXRX-AV02 Dual Enthalpy Upgrade Kit RXRX-AR02 Wall-mounted CO 2 Sensor Features Honeywell Controls Available as a Field Installed Accessory Only Gear Driven Direct Drive Actuator Fully Modulating (0-00%) Low Leakage Dampers Slip-In Design for Easy Installation Plug-In Polarized 2-pin Electrical Connections Pre-Configured No Field Adjustments Necessary Standard Barometric Relief Damper Single Enthalpy with Dual Enthalpy Upgrade Kit Available CO2 Input Sensor Available Field Assembled Hood Ships with Economizer Economizer Ships Complete for Horizontal Duct Application Optional Remote Minimum Position Potentiometer (Honeywell #S96B28) is Available from Prostock Field Installed Exhaust Available Rely on Ruud. 9

Accessories POWER EXHAUST KIT FOR RXRD-PGCM & SGCM ECONOMIZERS RXRX-BGF05 (C, D, or Y*) *Voltage Code VERTICAL AIRFLOW No. HP Low Speed High Speed ➀ FLA Model No. Volts Phase of Fans (ea.) CFM [L/s] ➁ RPM CFM [L/s] ➁ RPM (ea.) RXRX-BGF05C 2 208-20 0.75 400 [95] 850 5200 [2454] 050 5 RXRX-BGF05D 2 0.75 400 [95] 850 5200 [2454] 050 2.2.4 RXRX-BGF05Y 2 0.75 400 [95] 850 5200 [2454] 050.5 2.84 NOTES: ➀ exhaust is factory set on high speed motor tap. ➁ CFM is per fan at 0" w.c. external static pressure. LRA (ea.) 4.97 40 Rely on Ruud.

Accessories FRESH AIR DAMPER MOTORIZED DAMPER KIT RXRX-AWO (Motor Kit for RXRF-KFA) AXRF-KFA (Manual) AXRX-AWO (Motorized damper kit for manual fresh air damper) Rely on Ruud. 4

Accessories ROOFCURBS (Full Perimeter) Ruud s new roofcurb designs can be utilized on 5, 20 and 25 ton [52.8, 70. and 87.9 kw] models. One available height (4" [56 mm]). Quick assembly corners for simple and fast assembly. " [25.4 mm] x 4" [02 mm] Nailer provided. Insulating panels not required because of insulated outdoor base pan. Sealing gasket (28" [7 mm]) provided with Roofcurb. Packaged for easy field assembly. UNIT TYPICAL INSTALLATION ROOFCURB ASSEMBLY 42 Rely on Ruud.

Accessories ROOFCURB ADAPTER OLD MODELS OLD CURB MODEL ROOFCURB ADAPTER COMMERCIAL CABINET (2.5, 5 & 20 TON) ([44, 52.8 & 70. kw]) (-)RCF, (-)RGF, (-)REF RXRK-E56 RXRX-CJCE56 NEW MODEL (-)KNL (5, 20 & 25 TON) ([52.8, 70. & 87.9 kw]) COMMERCIAL CABINET (5, 20 & 25 TON) ([52.8, 70., 87.9 kw]) (-)KKB, (-)KMB, (-)KNB RXKG-CAF4 RXRX-CJCF4 (-)KNL (5, 20 & 25 TON) ([52.8, 70. & 87.9 kw]) Rely on Ruud. 4

Accessories CONCENTRIC DIFFUSER APPLICATION DOWNFLOW TRANSITION DRAWINGS RXMC-CJ07 (5 Ton) [52.8 kw] Used with RXRN-AD80 and RXRN-AD8 Concentric Diffusers. 44 Rely on Ruud.

Accessories DOWNFLOW TRANSITION DRAWINGS (Cont.) RXMC-CK08 (20 Ton) [70. kw] Used with RXRN-AD86 Concentric Diffusers. RXMC-CL09 (25 Ton) [87.9 kw] Used with RXRN-AD88 Concentric Diffusers. Rely on Ruud. 45

Accessories CONCENTRIC DIFFUSER RXRN-AD80 SERIES 5 TON [52.8 kw] FLUSH All aluminum diffuser with aluminum return air eggcrate. Built-in anti-sweat gasket. Molded fiberglass supports. Built-in hanging supports. Diffuser box constructed of sheetmetal insulated with " [25.4 mm].5 lbs. [.7 kg] duct liner. CONCENTRIC DIFFUSER SPECIFICATIONS PART NUMBER RXRN-AD80 CFM [L/s] STATIC PRESSURE THROW FEET 5600 [264] 0.6 28-7 5800 [277] 0.9 29-8 6000 [282] 0.42 40-50 NECK VELOCITY 000 06 07 JET VELOCITY 6200 [2926] 0.46 42-5 07 208 6400 [020] 0.50 4-52 4 279 6600 [5] 0.54 45-56 79 2454 2082 256 220 46 Rely on Ruud.

Accessories CONCENTRIC DIFFUSER RXRN-AD8 SERIES 5 TON [52.8 kw] STEP DOWN All aluminum diffuser with aluminum return air eggcrate. Built-in anti-sweat gasket. Molded fiberglass supports. Built-in hanging supports. Diffuser box constructed of sheetmetal insulated with " [25.4 mm].5 lbs. [.7 kg] duct liner. Double deflection diffuser with the blades secured by spring steel. CONCENTRIC DIFFUSER SPECIFICATIONS PART NUMBER RXRN-AD8 CFM [L/s] STATIC PRESSURE THROW FEET 5600 [264] 0.6 9-49 5800 [277] 0.9 42-5 6000 [282] 0.42 44-54 NECK VELOCITY 920 954 022 JET VELOCITY 6200 [2926] 0.46 45-55 056 056 6400 [020] 0.50 46-55 090 090 6600 [5] 920 954 022 0.54 47-56 24 24 Rely on Ruud. 47

Accessories CONCENTRIC DIFFUSER RXRN-AD86 SERIES 20 TON [70. kw] STEP DOWN All aluminum diffuser with aluminum return air eggcrate. Built-in anti-sweat gasket. Molded fiberglass supports. Built-in hanging supports. Diffuser box constructed of sheetmetal insulated with " [25.4 mm].5 lbs. [.7 kg] duct liner. Double deflection diffuser with the blades secured by spring steel. CONCENTRIC DIFFUSER SPECIFICATIONS PART NUMBER RXRN-AD86 CFM [L/s] STATIC PRESSURE THROW FEET 7200 [98] 0.9-8 7400 [492] 0.4 5-40 7600 [587] 0.4 6-4 NECK VELOCITY 827 850 87 JET VELOCITY 7800 [68] 0.47 8-4 896 896 8000 [776] 0.50 9-44 98 98 8200 [870] 0.5 4-46 94 94 8400 [964] 0.56 4-49 964 964 8600 [4059] 0.59 44-50 987 987 8800 [45] 0.6 47-55 00 00 827 850 87 48 Rely on Ruud.

Accessories CONCENTRIC DIFFUSER RXRN-AD88 SERIES 25 TON [87.9 kw] STEP DOWN All aluminum diffuser with aluminum return air eggcrate. Built-in anti-sweat gasket. Molded fiberglass supports. Built-in hanging supports. Diffuser box constructed of sheetmetal insulated with " [25.4 mm].5 lbs. [.7 kg] duct liner. Double deflection diffuser with the blades secured by spring steel. CONCENTRIC DIFFUSER SPECIFICATIONS PART NUMBER RXRN-AD88 CFM [L/s] STATIC PRESSURE THROW FEET 0000 [479] 0.5 46-54 0500 [4955] 0.58 50-58 000 [59] 0.65 5-6 NECK VELOCITY 907 95 998 JET VELOCITY 500 [5427] 0.7 55-64 04 04 2000 [566] 0.82 58-67 089 089 2500 [5898] 0.9 6-7 4 4 000 [64].00 64-74 79 79 907 95 998 Rely on Ruud. 49