EXBLI & EXBSPI Series. Circuit Breaker Panelboards for Harsh and Hazardous Environments

Similar documents
D2LC Series. Circuit Breaker Panelboards for Harsh and Hazardous Environments

P-2 D2P and EWP Factory Sealed Circuit Breaker Panelboards: Explosionproof, Dust-Ignitionproof, Watertight, Corrosion-Resistant

CIRCUIT BREAKER PANELBOARDS

FACTORY SEALED CIRCUIT BREAKER PANELBOARDS

TERMINAL BOXES FOR HARSH & HAZARDOUS ENVIRONMENTS

D2P and EWP Factory Sealed Circuit Breaker Panelboards Explosionproof, Dust-Ignitionproof, Watertight, Corrosion-Resistant

ATX DPD Series Distribution Panelboards Flameproof

Lighting and Power Distribution Panelboards

Division 1 Explosionproof Panelboards

Technical catalog February 2017 Low Voltage Switchboards and Panelboards UL/CSA

Application guide. Tmax Link OEM UL 891 Switchboard Program

P-9. ALPN, APPN and AGPN Series: Explosionproof, Dust-Ignitionproof, Watertight Non-Factory Sealed.

X1PB: Explosionproof Panelboards

LOW PROFILE LINEAR ALUMINUM LED EXCLUSIVE DESIGN FEATURES

LOW PROFILE LINEAR ALUMINUM LED EXCLUSIVE DESIGN FEATURES

ALPF Factory Sealed Lighting - APPF Power Distribution Panelboards Explosionproof, Dust-Ignitionproof, Watertight

XP Series Pre-Wired Factory Sealed Circuit Breaker Panelboards Explosionproof, Dust-Ignitionproof System

GHG43 Series Control Stations

Panelboard Protection on a Global Scale

SynergEX Panelboards for Hazardous Locations

Junction Boxes & Enclosures JBES and ECES Series: 316L Stainless Steel Enclosures Increased Safety

Eaton Corp. - Marina Power and Lighting, Inc. General Specifications for Lighthouse-SS Power Pedestals

L1L Series. LED Luminaire for Harsh and Hazardous Environments

Eaton Corp. - Marina Power and Lighting, Inc. General Specifications for Lighthouse Power Pedestal

HKH Series. HAZCON Controls for Harsh and Hazardous Environments

Hazardous Duty Applications

Benefits. Safety. Durability. Performance. Russellstoll. Heavy Industrial/ Marine

PLEXPOWER LIGHTING AND POWER PANELBOARDS PRODUCT GUIDE

1E EJB Junction Boxes Cl. I, Div. 1 and 2, Groups B, C, D

PlexPower Fused Factory Sealed Panelboard with Bus Bar Up to 30 Amps. Stainless Steel Enclosures

PlexPower Factory Sealed Panelboard 15 to 150 Amps. Stainless Steel Enclosures

Eaton Corp. - Marina Power and Lighting, Inc. General Specifications for Hatteras Light Pedestals

Pow-R-Line 3E Panelboard

INCANDESCENT/COMPACT FLUORESCENT/MEDIUM BASE HID

Miniature Circuit Breakers

Control Panels, Distribution Panels and Components

Standard Materials Bodies and covers: copper-free aluminum.

CYCLOPS X Purge Controller XP Version

Product Description. Junction Boxes...V1-V23 Meter and Instrument Enclosures...V24-V33

xboard safety, reliability effectively combining and performance safety, reliability and performance in commercial and industrial applications

1E EJB Junction Boxes Cl. I, Div. 1 and 2, Groups B, C, D

Proline Panelboard and breakers

Circuit Breakers Hazardous

2018 Consultant s Handbook Division 26 Electrical 2413 Switchboards

POWERPLEX PANELBOARD 1

EY, EYD, & ENY Series

SECTION PANELBOARDS

ALUMINUM OUTLET BODIES

EJB Enclosures. ATEX II 2 G Ex d IIB+H2 T6...T3 - II 2 D Ex td A21 T85 C C IECEx Ex d IIB+H2 T6...T3 - Ex td A21 T85 C...

PowerPact Q-Frame Molded Case Circuit Breakers and Switches (Types QB, QD, QG and QJ)

RCS1000 Data Sheet. RCS1000 Series Controllable Circuit Breaker Panel

Plugs and Receptacles: Hazardous Location

S200 UL 489 Series. Miniature circuit breakers S200. Features. Description

P-2 ccsaus, curus Class I Div. 2 Group B,C, D Class I Zone 1 AEx de IIB+H 2 T6 Ex d IIB+H 2 T6 U Type 4X, IP66

Mercmaster LED Series Luminaires Enclosed and Gasketed Fixtures

Enclosures. Section E

Linear Luminaire for Fluorescent Lamps Series EXLUX 6401

Arktite Plugs and Receptacles Industrial Heavy Duty Hazardous

Three Phase Explosion Proof Switch - Non Fused - 60 Amps - Early Break Auxiliary Contacts

Receptacle housing and cover optional malleable iron on EFS-M Series. Spring-loaded cover seats against neoprene gasket.

DISTRIBUTION SYSTEMS FOR GLOBAL APPLICATIONS

Design Standard. Purpose: Design Standard:

Receptacle housing and cover optional malleable iron on EFS-M Series. Spring-loaded cover seats against neoprene gasket.

Glass Reinforced Polyester Enclosures

Standard Finishes Receptacles: epoxy powder coat Cord connector housings and caps: epoxy powder coat

SECTION LOW VOLTAGE DISTRIBUTION EQUIPMENT

List Price. Mult. Sym. C Dim. Single Phase

1/4 thru 300 Hp NEMA 48 thru 449TY. List Price. Mult. Sym. C Dim. Single Phase

Enclosures for hazardous areas EBMX clamped enclosures. Clamped EBMX. NEMA 7 classifi ed enclosures

CIRCUIT BREAKERS. Explosionproof Circuit Breaker Enclosures EXPLOSIONPROOF MOTOR CONTROL EXPLOSIONPRROOF MOTOR CONTROL BREAKERS ENCLOSURES

Table Line and Load Terminals. Terminal Body Material. Wire Type. Aluminum Copper Aluminum. English English English.

Mid-West Instrument. Piston Type Model 220. Hazardous Locations. Indicating / Non-Indicating Differential Pressure Switch or Transmitter

Mid-West Instrument. Diaphragm Type Model 240. Hazardous Locations. Indicating / Non-Indicating Differential Pressure Switch or Transmitter

F-Series. Circuit Breaker

PLUGS AND RECEPTACLES: NEC/CEC HAZARDOUS LOCATION

P SERIES POWERPLEX DISTRIBUTION PANELBOARDS SAFETY MADE SIMPLE

Spring-loaded cover seats against neoprene gasket.

Load and Motor Switches, Load-Break Switches Series 8549

F-Series. Circuit Breaker

Explosionproof enclosures XPCJ series Cast aluminum steel control/junction box

A good connection. International approvals.

Capacitors. Individual & fixed bank. Individual & fixed capacitor banks. Low Voltage Network Quality

Explosion Proof Receptacle - Integral Circuit Breaker - Class 2 Division 1-30 Amp 480VAC

Power distribution SynergEX panelboards. SynergEX. Class I, Division 2 panelboards

Explosionproof Protection Simplified

MOGUL BASE HID FIXTURES

Selection and application guide

DISTRIBUTION EQUIPMENT: NEC/CEC HAZARDOUS LOCATION SWITCHES. Application

DBR Receptacle Class II, Division 1 and 2, Groups F, G Class III NEMA 3, 3R, 4, 4X, 9FG

EExe and EExi terminal boxes in polyester and aluminium for Ex areas

AM-Tite Series Non-Metallic Plugs MSR Series Switched and Interlocked Receptacles

Mipco Connections for Refrigerated Containers. No One Does It Like Mipco. The Mipco. Advantage. Reliability. Safety. Easy Installation & Service

CYCLOPS Z Purge Indicator

NEC/CEC CLASS/ZONE RATED HAZARDOUS LOCATION CIRCUIT BREAKERS. Application

NEC DBR Receptacle: Class II, Division 1 and 2, Groups F, G Class III NEMA 3, 3R, 4, 4X, 9FG

Intelligent Choice for Prestigious Buildings

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS

EDS / EFS Series Control Stations

ENR Value Series Dead Front Interlocked Circuit Breaking Receptacles

Key features. DESIGNS: - Conservator type - Hermetically sealed

Transcription:

EXBLI & EXBSPI Series Circuit Breaker Panelboards for Harsh and Hazardous Environments

KILLARK Z A H LO C NEMA 4X O Ring Gasket Stainless Steel Tri-Lead Cover New Slide MCB Assembly Handles Padlockable Dead Front Cover Spare Wires Slope Cover to eliminate Ice Buildup Concealed Hinge Factory Seals Line Side (Incoming Power) Quarter turn 316 Stainless Steel Latch Load Side (Outgoing Power with 20% spare wires) Gasket One Piece Ground Internal/ External Earthing Stud Ground Bar Neutral Bar 100% Rated DE2

KILLARK H A Z LO C IEC/NEC CIRCUIT BREAKER PANELBOARDS ATEX Certified Class I, Div. 1 & 2, Groups Bj,C,D Class I, Zones 1 & 2, Groups llb+h 2, lla Class II, Div. 1 & 2, Groups E,F,G Class III, Div. 1 & 2 Type 4, 4X, 7(B,C,D), 9(E,F,G) CENELEC/ATEX/IEC - Ex Ex d IIB + H2 T5 or T6 Ex td A21 IP66 Ta< +60 C #UL1203 Explosion Proof and Dust Ignition Proof Electrical Equipment. Files #E83969 & E12379 #C22.2 No. 30 Explosion Proof Enclosure for use in Class I Hazardous Locations. File #LR11716 FEATURES-SPECIFICATIONS Applications New to Killark are the IEC/NEC rated panelboards. If you have a Harsh and Hazardous location (corrosive, salt laden, flammable gas, vapors or explosive dust particles) this is where the Killark EXBLI or EXBSPI panelboard excels. Our new panelboard is suitable for use from the oil sands of Texas to the rigs of Saudi Arabia to the Far East. We have two types Our IEC (UL1077) panel offers both single and three phase applications with or without switched neutrals. Branch MCB s in single, two, three and four pole, RCBO s for earth leakage detection are available in 30, 100 or 300mA Sensitivity. Our NEC (UL489) panel offer single and three phase applications, branch MCB s in single, two, three and four pole. This type can also offer a factory sealed arrangement using our USF 316L stainless steel wiring chamber with or without removable gland plates. All incoming Line and outgoing Load connections are made in the wiring chamber; this eliminates the need for seal fittings for Division 2 area s. Features: All hardware is stainless steel, cover bolts are quick release Tri-Lead. All circuit breakers are pad lockable in the ON or OFF positions for up to three padlocks (to allow ease of lock out tag out capabilities. Insulated copper bus bars mount on our Din Rail mounted branch breakers and the cover of the explosion proof enclosure is pre-drilled for future expansion or changing breakers in the field. Solid neutral (tin plated) standard for single and three phase. ABB circuit breakers have a wide temperature range from -20 to +70 C. Standard Materials Breaker enclosure: Cast copper free aluminum (less than 4/10th of 1 %), Cover Bolts: Type 316 stainless steel quick turn (Tri-Lead), finish Aluminum Lacquer Paint. Electrical Ratings EXBLI 120/240 VAC, 3 Wire, 60hz 120/208 VAC, 4 Wire, 60Hz II 2 GD PTB 07 ATEX 1025U (Empty Housing) PTB 07 ATEX 1024x (Enclosures w/controls) IEC Ex 07.0022U IEC Ex 07.0023 Electrical Ratings EXBSPI 277 VAC, 3 Wire, 60hz 277/480Y VAC, 4 Wire, 60Hz Panel Selection Factors Basic information required when specifying panelboards is as follows: Service Requirements Voltage, phases and frequency Interrupting capacity Amperage Rating of Main (Lugs only or Breaker) Branch Breaker Requirements Type Number Poles Amperage RDC Requirements SUFFIX NUMBER DESCRIPTION SU-3B-4X Drain & Breather installed, NEMA 4X/7 BCD SU-10B-4X Drain installed, NEMA 4X/7 BCD SU-11B-4X Breather installed NEMA 4X/7 BCD SU-3ATEX Drain & Breather installed ATEX Group B EB Eyebolt, Qty of 2 TP Toe Plate (recommended for larger panels) GS150 150 Amp Ground Strap SUFFIX NUMBER SU1 SU9PEEEX SU9PEIO SU9PESEX SU14 SU93 DESCRIPTION Stainless steel external hardware NEMA 4X Grey powder polyester outer surface Grey powder polyester in & out surface Specify color outer surface (RAL number) Fungus proofing inner surface Do not paint j Conduits must be sealed within 18 for Group B applications. DE3

KILLARK Z A H LO C EXBLI LIGHTING PANELBOARD OPTIONAL NEC (UL 489) Factory Sealed Panelboard ELECTRICAL RATING 3 Wire with 120/240VAC 4 Wire with 120/208VAC NUMBER OF BRANCH POLE MAIN LUG ONLY MAIN LUG RATING AMP EXBLI LIGHTING PANELBOARD MAIN CIRCUIT BREAKER BASIC NUMBER PANEL SIZE 6 80 EXBLI-16ML80 H ELECTRICAL RATING NUMBER OF BRANCH POLE MAIN LUG RATING AMP BASIC NUMBER 12 130 EXBLI-112ML130 I 12 130 EXBLI-112MB* B 18 24 36 130 EXBLI-118ML130 EXBLI-124ML EXBLI-136ML J K L 3 Wire with 120/240VAC 18 24 36 130 EXBLI-118MB* EXBLI-124MB* EXBLI-136MB* C D E 54 EXBLI-154ML M 54 EXBLI-154MB* F PANEL SIZE 6 80 EXBLI-16MB* A 90 EXBLI-172ML N 72 EXBLI-172MB* G 6 80 EXBLI-36ML80 H 6 80 EXBLI-36MB* A 12 130 EXBLI-312ML130 I 12 130 EXBLI-312MB* B 18 24 36 130 EXBLI-318ML130 EXBLI-324ML EXBLI-336ML J K L 4 Wire with 120/208VAC 18 24 36 130 EXBLI-318MB* EXBLI-324MB* EXBLI-336MB* C D E 54 EXBLI-354ML M 54 EXBLI-354MB* F 90 EXBLI-372ML N 72 EXBLI-372MB* G DE4

KILLARK H A Z LO C EXBSPI LIGHTING PANELBOARD Catalog Logic for basic IEC Panelboard Enclosures Constant For Series L - Lighting 240V SP - Small Power 480Y/277 IEC Type 1-3 - Number Of Branch Poles 6, 12, 18, 24, 36, 54, or 72 (up to 90 CKT for MLO) ML - Main Lug MB - Main Breaker Main Breaker Trip Amps 15A to 225A Consult factory with branch breaker requirements EXB L I 3 6 ML 80 ELECTRICAL RATING 3 Wire with 277VAC 4 Wire with 277/480YVAC NUMBER OF BRANCH POLE EXBSPI LIGHTING PANELBOARD MAIN LUG ONLY MAIN CIRCUIT BREAKER MAIN LUG RATING AMP BASIC NUMBER PANEL SIZE ELECTRICAL RATING NUMBER OF BRANCH POLE MAIN LUG RATING AMP BASIC NUMBER 6 80 EXBSPI-16ML80 H 6 80 EXBSPI-16MB* A 12 130 EXBSPI-112ML130 I 12 130 EXBSPI-112MB* B 18 130 EXBSPI-118ML130 J 18 130 EXBSPI-118MB* C 24 EXBSPI-124ML K 3 Wire with 24 EXBSPI-124MB* D 36 EXBSPI-136ML L 277VAC 36 EXBSPI-136MB* E 54 EXBSPI-154ML M 54 EXBSPI-154MB* F 90 EXBSPI-172ML N 72 EXBSPI-172MB* G 6 80 EXBSPI-36ML80 H 6 80 EXBSPI-36MB* A 12 130 EXBSPI-312ML130 I 12 130 EXBSPI-312MB* B 18 130 EXBSPI-318ML130 J 18 130 EXBSPI-318MB* C 24 EXBSPI-324ML K 4 Wire with 24 EXBSPI-324MB* D 36 EXBSPI-336ML L 277/480YVAC 36 EXBSPI-336MB* E 54 EXBSPI-354ML M 54 EXBSPI-354MB* F 90 EXBSPI-372ML N 72 EXBSPI-372MB* G PANEL SIZE DE5

KILLARK Z A H LO C BREAKER RATINGS TYPE S200C S200D S200M POLE VOLTS VAC EXBLI & EXBSPI CIRCUIT BREAKER RATINGS, ABB IEC (UL1077), MCB AMPERES SYMMERTICAL TYPE RCBO POLE VOLTS VAC AMPERES SYMMERTICAL SENSITIVITY 1 277 6,000 AIC DS201 1+N 230 10,000 AIC 30, 100, 300mA 2 277/480Y 6,000 AIC DS202 2 230 10,000 AIC 30, 300mA 3 277/480Y 6,000 AIC 4 277/480Y 6,000 AIC 1 277 6,000 AIC 2 277/480Y 6,000 AIC 3 277/480Y 6,000 AIC 4 277/480Y 6,000 AIC 1 277 10,000 AIC 2 277/480Y 10,000 AIC 3 277/480Y 10,000 AIC 4 277/480Y 10,000 AIC NEC (UL489), MCB, NOT RATED FOR SWITCHED NEUTRAL TYPE SU200MC S200U-K S200UP-K POLE VOLTS VAC AMPERES SYMMERTICAL 1 240 10,000 AIC 2 277/480Y 10,000 AIC 3 277/480Y 10,000 AIC 4 277/480Y 10,000 AIC 1 240 10,000 AIC 2 240 10,000 AIC 3 240 10,000 AIC 4 240 10,000 AIC 1 277 10,000 AIC 2 277/480Y 10,000 AIC 3 277/480Y 10,000 AIC 4 277/480Y 10,000 AIC TYPE Tmax T1* Tmax T2 Tmax T3 Tmax T4 Tmax XT1 Tmax XT2 Tmax XT3 Tmax XT4 * Will be obsolete by 2018 POLE MAIN CIRCUIT BREAKER VOLTS VAC AMPERES SYMMERTICAL AMP TRIP 3 347/600Y 22,000 AIC 15-100 4 347/600Y 22,000 AIC 15-100 3 480 35-65,000 AIC 15-100 4 480 35-65,000 AIC 15-100 3 347/600Y 25-35,000 AIC 60-225 4 347/600Y 25-35,000 AIC 60-225 3 600 25-35,000 AIC 125-250 4 600 25-35,000 AIC 125-250 3 347/600Y 25, 35, 65,000 AIC 15-125 4 347/600Y 25, 35, 65,000 AIC 15-125 3 600 25, 35, 65,000 AIC 15-125 4 600 25, 35, 65,000 AIC 15-125 3 347/600Y 25, 35, 65,000 AIC 60-225 4 347/600Y 25, 35, 65,000 AIC 60-225 3 600 25, 35, 65,000 AIC 25-250 4 600 25, 35, 65,000 AIC 25-250 Main Circuit Breaker Main Lug Only Main Circuit Breaker Main Lug Only w/ Switched Neutral 4 Pole Main Circuit Breaker w/ Switched Neutral Main Lug Only DE6

KILLARK H A Z LO C IEC CIRCUIT BREAKER PANELBOARDS # OF CIRCUITS W/MAIN BREAKER EXB-12126 N34 6 1-1/2 3/4 3 EXB-14146 N34 12 1-1/2 3/4 6 EXB-16166 N34 18 1-1/2 3/4 9 EXB-18186 N34 24 1-1/2 3/4 12 EXB-18248 N34 36 1-1/2 3/4 18 EXB-18368 N34 54 2-1/2 3/4 20 7 EXB-24368 N34 72 2-1/2 3/4 30 6 # OF CIRCUITS MAIN LUG ONLY EXB-8106 N34 6 1-1/2 3/4 3 EXB-8126 N34 12 1-1/2 3/4 6 EXB-12186 N34 18 1-1/2 3/4 9 EXB-12186 N34 24 1-1/2 3/4 12 EXB-18186 N34 36 1-1/2 3/4 16 2 EXB-18368 N34 54 2-1/2 3/4 20 7 EXB-24368 N34 72 2-1/2 3/4 18 18 EXB DIMENSIONS MAIN BREAKER STD CONDUITS AT BOTTOM (NPT) EXTERNAL DIMENSION (NI) MOUNTING DIMENSIONS (INCHES) QTY B A B QTY B F G H I J K L M RH SIDE 16.38 (416) 19.25 (489) 20.38 (518) 23.25 (591) 29.25 (743) 19.25 (489) 20.38 (518) 23.25 (591) 28.38 (721) 40.38 (1026) 41.25 (1048) 8.69 (221) 9.40 (239) 9.19 (233) 10 (254) 11.75 (298) 12.38 (314) 12.4 (315) 6.94 (176) 9.00 (229) 10.94 (278) 13 (330) 13.25 (337) 19.56 (497) 6.94 (176) 9.00 (229) 10.94 (278) 19 (483) 31.5 (800) 31.56 (802) 14.94 (379) 17.00 (432) 18.94 (481) 21.38 (543) 21 (533) 21 (533) 27.56 (700) 14.94 (379) 17.00 (432) 18.94 (481) 21.38 (543) 27 (686) 39.5 (1003) 39.56 (1005) EXB DIMENSIONS MAIN LUG ONLY STD CONDUITS AT BOTTOM (NPT) EXTERNAL DIMENSION (NI) MOUNTING DIMENSIONS (INCHES) QTY B A B QTY B F G H I J K L M RH SIDE 12.32 (313) 13.25 (337) 16.38 (416) 16.38 (416) 23.25 (591) 29.25 (743) 14.32 (364) 17.25 (438) 23.25 (591) 40.38 (1026) 41.25 (1048) 8.32 (211) 8.70 (221) 9.06 (230) 9.06 (230) 10 (254) 12.38 (314) 12.4 (315) N/A 3.82 (97) 6.94 (176) 6.94 (176) 13.25 (337) 19.56 (497) 8.00 (203) 7.82 (199) 12.88 (327) 12.88 (327) 31.5 (800) 31.56 (802) 9.88 (251) 10.38 (264) 14.94 (379) 14.94 (379) 21.38 (543) 21 (533) 27.56 (700) N/A 14.38 (365) 20.88 (530) 20.88 (530) 21.38 (543) 39.5 (1003) 39.56 (1005) LBS (KG) 112 (50.80) 160 (72.57) 195 (88.45) 256 (116.12) 290 (131.54) 440 (199.58) 560 (254.01) LBS (KG) 112 (50.80) 160 (72.57) 195 (88.45) 256 (116.12) 290 (131.54) 440 (199.58) 560 (254.01) DE7

Distribution Equipment from KILLARK B7C Circuit Breaker Enclosures Available from 15AT thru 1200AT, two, three or four pole, available with standard NPT outlets, Metric or both. Mounting pans are pre-drilled to accept the following molded case circuit breakers (Square D, ABB, Eaton, GE and Siemens). All external circuit breaker operating handles are padlock able in the on or off position. Ductile mounting lugs for adjusting to irregular mounting surfaces. All cover bolts are 316 grade stainless steel. B7L Lighting Panelboard Available from 12 to 42 circuits for MLO (main lug only) to MCCB (main circuit breaker) styles. All external circuit breaker operating handles are padlock able in the on or off position. All cover bolts are quick release tri-lead 316 grade stainless steel, ductile mounting lugs. D2LC Series New from Killark is the factory sealed lighting panelboards with type UL 489 miniature circuit breakers (MCB) along with silver plated copper bus chassis. This new design offers a full range of molded case circuit breakers for the main circuit breaker along with a full range (12, 18, 30, 36 and 42 circuit chassis). Line (incoming power) and Load (outgoing power) connections are pre-wired to a stainless steel wiring chamber. This will eliminate the need for pouring seals and make for a quicker connection. Switchrack Assemblies Integrated solution for group mounting Explosion proof or Flameproof enclosures, mounted and wired. Available with conduit and fittings or armored cable and cable glands. Structures are designed for the specific seismic and wind load requirements for your specific location. Whatever your requirements, we can provide a solution. HKSB-EXBLI 11-17 Killark, 2017 Hubbell Killark 3940 Dr. Martin Luther King Drive St. Louis, MO 63113 Phone: (314) 531-0460 Fax: (314) 531-7164 www.hubbell-killark.com