DIESEL GENERATOR SET MTU 12V4000 DS2000 380V 11 kv/50 Hz/Standby Power with overload/nea (ORDE) Optimized MTU 12V4000G63/Water Charge Air Cooling Optional equipment and finishing shown. Standard may vary. PRODUCT HIGHLIGHTS // Benefits - Low fuel consumtion - Optimized system integration ability - High reliability - High availability of power - Long maintenance intervals // MTU Onsite Energy is a single-source supplier // Support - Global product support offered // Standards - Engine-generator set is designed and manufactured in facilities certifi ed to standards ISO 2008:9001 and ISO 2004:14001 - Generator set complies to ISO 8528 - Generator meets NEMA MG1, BS5000, ISO, DIN EN and IEC standards - NFPA 110 // Power Rating - System ratings: 1800 kva - 1850 kva - Accepts rated load in one step per NFPA 110 - Generator set complies to G3 according to ISO 8528-5 - Generator set exceeds load steps according to ISO 8528-5 // Performance Assurance Certification (PAC) - Engine-generator set tested to ISO 8528-5 for transient response - 85% load factor - Verifi ed product design, quality and performance integrity - All engine systems are prototype and factory tested // Complete range of accessories available - Control panel - Circuit breaker/power distribution - Fuel system - Fuel connections with shut-off valve mounted to base frame - Starting/charging system - Exhaust system - Mechanical and electrical driven radiators - Medium voltage alternators // Emissions - NEA (ORDE) optimized // Certifications - CE certifi cation option
2 / / / MTU 12V4000 DS2000 / 50 Hz / 380V - 11kV APPLICATION DATA ➀ // Engine Manufacturer MTU Model 12V4000G63 Type 4-cycle Arrangement 12V Displacement: l 57.2 Bore: mm 170 Stroke: mm 210 Compression ratio 16.4 Rated speed: rpm 1500 Engine governor ADEC Max power: kwm 1575 Air cleaner Dry // Fuel System Maximum fuel lift: m 5 Total fuel flow: l/min 16 l/hr g/kwh At 100% of power rating: 377.6 199 At 75% of power rating: 288.9 203 At 50% of power rating: 200.2 211 // Liquid Capacity (Lubrication) Total oil system capacity: l 260 Engine jacket water capacity: l 160 Intercooler coolant capacity: l 40 // Combustion Air Requirements Combustion air volume: m 3 /s 1.98 Max. air intake restriction: mbar 50 // Cooling/Radiator System Coolant flow rate (HT circuit): m 3 /h 56 Coolant flow rate (LT circuit): m 3 /h 30 Heat rejection to coolant: kw 580 Heat radiated to charge air cooling: kw 310 Heat radiated to ambient: kw 75 Fan power for mech. radiator (40 C): kwm 55 // Exhaust System Exhaust gas temp. (after turbocharger): C 510 Exhaust gas volume: m 3 /s 5.29 Maximum allowable back pressure: mbar 85 Minimum allowable back pressure: mbar 30 ➀ All data refers only to the engine and is based on ISO standard conditions (25 C and 100m above sea level). ➁ Values referenced are in accordance with ISO 3046-1. Conversion calculated with fuel density of 0.83 g/ml. All fuel consumption values refer to rated engine power.
3 / / / MTU 12V4000 DS2000 / 50 Hz / 380V - 11kV STANDARD AND OPTIONAL FEATURES // System Ratings (kw/kva) Generator model Voltage NEA (ORDE) optimized 40 C/100m without radiator with mechanical radiator with electr. driven radiator kwel kva* AMPS kwel kva* AMPS kwel kva* AMPS Marathon 744RSL7091 380 V 1480 1850 2811 1440 1800 2735 1440 1800 2735 (Low voltage 400 V 1480 1850 2670 1440 1800 2598 1440 1800 2598 marathon standard) 415 V 1480 1850 2574 1440 1800 2504 1440 1800 2504 Marathon 744RSL7092 380 V 1480 1850 2811 1440 1800 2735 1440 1800 2735 (Low voltage 400 V 1480 1850 2670 1440 1800 2598 1440 1800 2598 marathon oversized) 415 V 1480 1850 2574 1440 1800 2504 1440 1800 2504 Leroy Somer LSA 51.2 M60 380 V 1480 1850 2811 1440 1800 2735 1440 1800 2735 (Low voltage 400 V 1480 1850 2670 1440 1800 2598 1440 1800 2598 Leroy Somer) 415 V 1480 1850 2574 1440 1800 2504 1440 1800 2504 Marathon 1020FDH7096 11 kv 1480 1850 97 1440 1800 94 1440 1800 94 (Medium volt. marathon) Leroy Somer LSA 53.1 UL70 11 kv 1480 1850 97 1440 1800 94 1440 1800 94 (Medium volt. Leroy Somer) * cos phi = 0,8 // Engine 4-Cycle Standard single stage air filter Oil drain extension & shut-off valve Closed crankcase ventilation Governor-electronic isochronous Common rail fuel injection NEA (ORDE) optimized engine // Generator NEMA MG1, BS5000, ISO, DIN EN and IEC standards Self-ventilated Superior voltage waveform Solid state, volts-per-hertz regulator No load to full load regulation ±0,25% voltage regulation no load to full load Brushless alternator with brushless pilot exciter 4 pole, rotating fi eld Sustained short circuit current of up to 250% of the rated current for up to 10 seconds (marathon generator) Sustained short circuit current of up to 300% of the rated current for up to 10 seconds (Leroy Somer generator) Marathon low voltage generator Leroy Somer generator Oversized generator Medium voltage generator // Cooling System Jacket water pump Thermostat(s) Water charge air cooling Mechanical radiator Electrical driven front-end cooler Jacket water heater Represents standard features Represents optional features
4 / / / MTU 12V4000 DS2000 / 50 Hz / 380V - 11kV STANDARD AND OPTIONAL FEATURES, CONTINUATION // Control Panel Pre-wired control cabinet for easy application of customized controller (V1+) Island operation (V2) Automatic mains failure operation with ATS (V3a) Automatic mains failure operation incl. control of generator and mains breaker (V3b) Island parallel operation of multiple gensets (V4) Automatic mains failure operation with short (< 10s) mains parallel overlap synchronization (V5) Mains parallel operation of a single genset (V6) Mains parallel operation of multiple gensets (V7) Basler controller Deif controller Complete system metering Digital metering Engine parameters Generator Protection Functions Engine protection SAE J1939 engine ECU communications Parametrization software Multilingual capability Multiple programmable contact inputs Multiple contact outputs Event recording IP 54 front panel rating with integrated gasket Different expansion modules Remote annunciator Daytank control Generator winding temperature monitoring Generator bearing temperature monitoring Differential protection with multi-finction protection relay Modbus RTU-TCP gateway // Circuit Breaker/Power Distribution 3-pole circuit breaker 4-pole circuit breaker Manual-actuated circuit breaker Electrical-actuated circuit breaker Stand-alone solution in seperate switch box // Fuel System Flexible fuel connectors mounted to base frame Fuel filter with water separator Switchable fuel filter with water separator Seperate fuel cooler Fuel cooler integrated into cooling equipment // Starting/Charging System 24V starter Starter batteries Battery rack & cables Battery charger Represents standard features Represents optional features
5 / / / MTU 12V4000 DS2000 / 50 Hz / 380V - 11kV STANDARD AND OPTIONAL FEATURES, CONTINUATION // Mounting System Welded base frame Resilient engine and generator mounting Modular base frame design // Exhaust System Exhaust bellows with connection flange Exhaust silencer with 10 db(a) sound attenuation Exhaust silencer with 30 db(a) sound attenuation Exhaust silencer with 40 db(a) sound attenuation Y-connection-pipe Represents standard features Represents optional features
6 / / / MTU 12V4000 DS2000 / 50 Hz / 380V - 11kV WEIGHTS AND DIMENSIONS Drawing above for illustration purposes only, based an standard open power 400 Volt engine-generator set. Lengths may vary with other voltages. Do not use for installation design. See website for unit specific template drawings. System Dimensions (L x W x H) Weight (dry/less tank) Open Power Unit (OPU) 4584 x 1836 x 2330 mm 10877 kg Weights and dimensions are based on open power units and are estimates only. Consult the factory for accurate weights and dimensions for your specific engine-generator set. SOUND DATA // Consult your local MTU Onsite Energy distributor for sound data. EMISSIONS DATA // Consult your local MTU Onsite Energy distributor for emissions data. RATING DEFINITIONS AND CONDITIONS // Standby ratings apply to installations served by a reliable utility source. The standby rating is applicable to varying loads for the duration of a power outage. A 10% overload capacity is available for one hour in twelve. Ratings are in accordance with ISO 8528-1, ISO-3046-1, BS 5514 and AS 2789. Average Load Factor: 85%. Operating hours/year: max. 500. // Deration factor: Altitude: Consult your local MTU Onsite Energy Power Generation distributor for altitude derations. Temperature: Consult your local MTU Onsite Energy Power Generation distributor for temperature derations. Rated power is available up to 40 C and 100m above sea level. Subject to change. 3238561 Edition 01/14 ENC 2014-07. Materials and specifications subject to change without notice. MTU Onsite Energy A Rolls-Royce Power Systems Brand www.mtuonsiteenergy.com