Level and Flow Measurement. Sludge Finder 2

Similar documents
Ultrasonic Sludge Blanket Monitoring System

Mobrey MSM400 Ultrasonic sludge density measurement system

Ultrasonic Sludge Blanket Monitoring System

Sludge Blanket Level Measurement

MAIN FUNCTION FEATURES. . D = v t /2

VALVE CONTROLLERS Controllers for Dust Extr 2010 / 2011 action Technology

Superstatic 440. Static Heat Meter, Static Cooling Meter. Application

DSL-220 MkIII Single Pass Opacity Monitor Measures 0-100% Opacity

DSL-240 MkIII Single Pass Dust Monitor Measures mg/m 3 using DDP

Superstatic 440. Static Heat- and Cooling Meter. Application

P U L S A R point 210

HUMIDITY / TEMPERATURE TRANSMITTER

Turbidity and Suspended Solids Transmitter

ULTRAFLO 2000 ULTRASONIC LIQUID FLOW AND HEAT/ENERGY METERS FOR PERMANENT INSTALLATION HIGH TEMPERATURE SENSORS AS STANDARD

Model DFX Doppler ultrasonic flow meter

Controller Specification Sheet

mass flowmeter for compressed air

Delta Products VFD CP2000 Bypass Control Packages.

Lower maintenance costs: with no moving parts, there is nothing on the DFX to wear down. Wide measuring range: 0.15 to 30 FPS (0.05 to 9 MPS).

DS DC1100 Energy Controller SELF CONFIGURING OPTIMISER/COMPENSATOR WITH BOILER SEQUENCE AND HWS CONTROL

Marsh McBirney Flo-Dar

QUANTUM LX CONTROL PANEL

Logic module. Brief description. Features. Block structure. Data Sheet Page 1/5

RMF SYSTEMS CONDITION MONITORING CENTER PURE POWER

AQUAVAR Intelligent Pump Controller TECHNICAL BROCHURE BCPAQIPC R2

Presentation Soft starters 0 Altistart 48 soft start - soft stop units

Range of Ultrasonic Flowmeters.

Royce Total Suspended Solids Systems. Water & Wastewater

Suitable for all water based foam applications. Unique IMA Sensing technology ensures reliability. Increases throughput by reducing downtime

sinamics SINAMICS G110 Variable Speed Drives 0.12 kw to 3 kw SINAMICS G110 Short Form 2004

Power Switching Devices

MAIN FUNCTION FEATURES. . D = v t /2

EM DC Multi-Function DC Energy Meter

Technical Datasheet. Compact DC Energy Meter. Multi-Function DC Energy Meter

SonoMeter 30 Energy Meters

Cellwatch Battery Monitoring Systems

Optidew Vision Optical Dew-Point Meter

Ultrasonic filling level sensor UFM 200 / 600 C2 / C4 / R / MD

Softstarters. Softstarters Type SSM Medium voltage ,800V 1

AMI. American Magnetics, Inc. Excellence in Magnetics and Cryogenics

ProSeries NEMA 4X SONIC-PRO. Engineering and Technical Data. Transit Time Ultrasonic Flowmeter. Industries, Ltd. s Ultrasonic Flow Meters

Dycon D2430 EN54-4 Fire Alarm Power Supply Series

SonoMeter 30 Energy Meters

tprime TM Series 280T

Temperature multi-function calibrator Model CTM

flow x3 flow monitoring

Superstatic 749. Fluidic Oscillation Compact Heat Meter

Data Sheet Type FF420. Series 420 Specification Flange / Flange. Series 420 Non-Contact Rotary Torque Transducer

UTM10 Series Ultrasonic Transit-time Flowmeters

Fluidic Oscillation Compact Heat Meter of High-Tech Composite

Communication module. Brief description. Block structure Features. Page 1/5. Data Sheet

Observe all necessary safety precautions when controlling the soft starter remotely. Alert personnel that machinery may start without warning.

Belt Scales Table of Contents

Compact Static Heat Meter of High-Tech Composite

QUOTATION BLADE 7 LX. Product code GEAL6S2BAA

MagFlux Q 8200 Series

Technical Datasheet. Multi-channel support RTC with Data Storage RS485 Output Alarming & Protection Onsite Programmable Load Profile Analysis

ULTRASONIC HEAT METER

Low voltage AC drives

Alpha EM DC Multi-Function DC Energy Meter. Technical Datasheet. Compact DC Energy Meter

Electromagnetic flowmeters Series FLOMAT Insertion electromagnetic flowmeter for conductive liquids

We reserve the right to alter data according to improvements made. Previous documents become invalid with the issue of this document.

Sentinel LCT. Panametrics Ultrasonic Flowmeter for Liquid Custody Transfer Measurement. GE Measurement & Control. Benefits.

Fluidic Oscillation Compact Heat Meter

GS2 Series - Introduction

Accurate to 0.1 NIST Traceable Advanced PID Algorithm USB Port Free datalogging/control software

Level Measurement Point level measurement - RF Capacitance switches

STUF-280W. Features: Ultrasonic Water Meter, DN15~DN40. Ultrasonic Water Meter DN50~DN600

CAPACITIVE LEVEL SWITCHES. Capacitive switch catalogue HYC-CSC01 Elect. Iss. 01

DGC-2020 DIGITAL GENSET CONTROLLER

DLRO 10 and DLRO 10X. Digital Microhmmeter. DLRO 10 and DLRO 10X Digital Microhmmeter. NEW interchangeable test lead terminations

IRT 4000 AT-S/M/L. Technical Manual. quality IN MOTION. quality IN MOTION

Level Measurement. Point level measurement Capacitance switches. Pointek CLS200 Standard. icenta Controls Ltd

Special voltages: Voltage >500 V AC are only permissible with external control box. 3-phase AC Voltages/frequencies. 1-phase AC Voltages/frequencies

DIESEL Engine Fire Pump Controllers Features

Series 500. Liquid Level Transmitters. Instruction Manual

SD1 Series General Purpose AC Variable Speed Drives

DATA SHEET Genset Control Unit, GCU 100

T-Sense _ 660. Optical Torque Measuring Systems. Product Bulletin

ALR output Powerfull PROGRAMMABLE POWER SUPPLY 640 WATTS 0-32V 0-20A POWERFUL. Specifications

A. Provide variable frequency drives to operate variable torque loads as shown on the Drawings and as specified herein.

Pressure Transmitter

Residential. Ultrasonic Cooling Meter ULTRACOLD T350 (2WR6...) A customer tailored cooling meter designed for residential needs and easy billing

SIGMA SERIES DE METER

A. Danfoss VLT Soft Starter The single speed drive. For any soft start situation MAKING MODERN LIVING POSSIBLE

A Higher Level of Performance. Data Sheet. Centurion. Guided Radar. CGR Series. For more information, please visit >

Magnetic-inductive flow measurement device Type VOLUMTEC - best performance

Frost protection for pipes. 16 Technical handbook. Thermostat with line or ambient temperature sensor

110 Years Expertise DC Motors AC Motors Digital Drives MOTOR CONTROL TECHNOLOGY PRODUCT CATALOGUE THREE PHASE DRIVES: TT/X RANGE

SED2. Variable Frequency Drives. with Conventional Bypass Options. Variable Frequency Drives. Description. Features F-9.

1 potential-free change-over contact (max. 24 V DC/1 A) for SIL collective failure signal SIL functions - safety functions Standard: Safe ESD

ROBICON W120 enclosed drive

US-S/FFL. Ultrasonic energy meters. Function. Flexible design. Connection. Mounting. High reliability


GEMÜ 549 esydrive Motorized globe valve

1/2 thru 1.5 Hp 1/2 thru 3 Hp 2 thru 5 Hp 1 thru 10 Hp

Flow VA 500/ 520. Flow sensors for compressed air and gases incl. temperature measurement. Verbrauch.

Sentinel LCT. Panametrics Ultrasonic Flowmeter for Liquid Custody Transfer Measurement. GE Sensing & Inspection Technologies. Benefits.

Sentinel Panametrics Custody Transfer Gas Ultrasonic Flowmeter

Field IT Actuators & Positioners Rotary Actuators - Rated Torque 100 Nm (80 ft-lbs) PME 120-AI/AN. Rotary Actuators Rated Torque 100 NM (80 ft-lbs)

Transcription:

Level and Flow Measurement Sludge Finder 2

Sludge Finder 2 Sludge Finder 2 Is a proven effective sludge blanket interface monitor in both waste water and industrial applications. Sludge Finder 2 provides a continuous level indication and 4 20 ma output of interface height from the tank bottom along with relays for alarm or control use. Sludge Finder 2 monitors SBR tanks, primary or secondary settlement tanks down to 0.5% density. Prompt Led Set Up Easy drop down menu allows quick set up, the clear large display offers a choice of menus and the interface echo can be constantly seen if needed. Self Cleaning Viper Transducer The Viper transducer complete with a sweep clean wiper removes dirt and air from the transducer face. A second transducer may be added to the controller giving two channel ability if needed. The second transducer may be a through air ultrasonic unit, enabling the second channel to monitor level of liquid or solids, particularly useful in mineral or mining applications.

Sludge Finder 2: Sludge interface monitor Features Continuous single or dual channel level control choice High frequency gives high reliability long term Self cleaning transducer removes need for regular inspection SBR tank applications can be monitored Easy set up, via drop down menu on large clear display Unit can track two different echoes with one transducer and output two 4-20mA signals one for each interface Optional Radio Telemetry System RADIO TELEMETRY SYSTEM AVAILABLE AS AN OPTION Pulsar s Sludge Finder 2 is a versatile, accurate and reliable solution to the problem of accurately measuring interface levels in primary or secondary settlement tanks and SBR systems. Operating ultrasonically through liquid, Sludge Finder 2 uses proven echo processing algorithms to identify the sludge interface level by state of the art digital echo processing techniques found only in this unit. Sludge Finder 2 s unique Viper transducer is immersed in the liquid, emitting a high frequency ultrasonic pulse down towards the sludge interface. The pulse reflects from the interface of the denser material back to the Viper transducer face. This echo is analysed by the controller unit providing a depth reading and an analogue output proportional to the height of the interface above the vessel bottom. Multiple Tanks, Multiple Applications Sludge Finder 2 will operate with one or two transducers: you can mix and match Sludge Transducers and Pulsar s main db transducer range to give astonishing versatility. Manage two clarifiers/thickeners, or one clarifier plus an ultrasonic level application from a single unit, providing flexible, economical control and a single connection point for system interface. Use Sludge Finder 2 in: Primary and secondary settlement tanks Clarifiers and reactor clarifiers Stationary and travelling bridge applications Gravity thickeners DAF thickeners Sequential batch reaction tanks Industrial process thickeners Output Options Sludge FInder 2 features 4-20mA isolated outputs for each channel, with optional RS485 connection (Modbus or Profibus). Six control relays are included (5A rated), assignable to any channel. An optional Radio Telemetry System may be fitted with a 3km (1.86miles) line-of-sight range. Up to 48 Nodes can be used using a 'Multihop' receiver installation. The hygienic solution Sludge Finder 2 features a microprocessor and a multifunction display showing blanket level, complete echo profile, alarm points, tank depth and multiple tank status. Remote measurement with Sludge Finder 2 means you can put an end to tedious, time consuming, potentially unhygienic and hazardous manual measurements using gap switches or vacuum probes. Self-cleaning transducer Sludge Finder 2 is designed to be maintenance free. Sludge Finder s Viper transducer is a single beam ultrasonic unit immersed just below the liquid surface. A wiper blade sweeps the transducer face, ensuring that it remains clean. The Viper transducer may be positioned up to 200m from the control unit and has a measurement range of 0.3 to 10m. Accuracy is 0.25% of the measured range. A tight 6 beam angle and sophisticated echo processing algorithms makes sure that Sludge Finder 2 deals with difficult tanks and rotating equipment with ease.

Sludge Finder 2: Prompt led set-up Easy installation and set-up Sludge Finder 2 is simply installed and the transducer cable can be easily extended with twin pair screened cable. To program Sludge Finder 2, the operator enters operating parameters via a menu driven operator interface and the Sludge Finder 2 automatically tracks to the blanket interface. Sludge Finder 2 s operator interface consists of several screens that make setting up the unit straightforward and communicates information about the process quickly, clearly and concisely. Features Relay choices for alarm or pump control function Reliable monitoring down to 0.5% density Second transducer may be interface Viper transducer or an air transducer for liquids or solids level measurement 200m separation distance between Viper and controller using standard cable Multiple Layer Tracking TYPICAL SCREEN SHOTS THROUGH MENU Sludge Finder 2 allows a user to set up two interface points to display, and to control the process via the echo profile returned from a single self-cleaning Viper transducer. One of the primary benefits is the ability to monitor sludge interface levels of differing densities. This new feature could reveal a high level of FLOC spilling into the local water course, potentially causing pollution and a breach of consent at the same time as measuring and controlling the RAS layer in the normal way. The unit can output two isolated 4-20mA signals, one for each interface. TYPICAL PROFILE OF DUAL POINT A TYPICAL ECHO PROFILE VIEWED ON OPTIONAL SLUDGE PC SOFTWARE

Sludge Finder 2: Viper Transducer Features Keeps algae and other growth off the face Flexible transducer arm option, allows rotating bridges to be used Mounting bracket options available Self-cleaning transducer The Viper transducer is designed to operate continually immersed in liquid, and features an oscillating wiper blade to keep the face free of algae or bacterial growth that could otherwise affect performance. The wiper also effectively clears air bubbles from the transducer face, while the 0.2mm gap between the wiper and the transducer face makes sure there is no wear between the surfaces. The sweep action of the wiper discourages 'hair' build up, ensuring that the shaft does not lock up over time. VIPER MOUNTED BEHIND SURFACE SKIMMER AND IN FRONT OF ROTATING BRIDGE FRONT VIEW OF VIPER FACE SHOWING WIPER 78mm 1"BSP 185mm 10mm 98mm Max. BOTTOM MATERIAL: BLACK VALOX 357 VIPER TRANSDUCER VIPER TRANSDUCER ON CONDUIT WITH ROTAT- ING BRIDGE

Technical Specification: Sludge Finder 2 PHYSICAL: Wall Mount: External dimensions: Weight Nominal: Enclosure material/description: Cable entry detail: Transducer cable extensions: Maximum separation: ENVIRONMENTAL: IP Rating (Wall): Max. and min. temp. (electronics): CE approval: SONAR (INTERFACE) PERFORMANCE: Accuracy: Resolution: Max. range: Min. range: 235 x 184 x 120 mm (9.25 x 7.24 x 4.72in) 1 kg (3.3lbs) Polycarbonate, flame resistant to UL94-5V 10 cable entry knock outs, 5 x M20 and 1 x M16 underside, 4 x PG11 at rear 2 x twin pair with overall screen 200m (656ft) from transducer to transceiver IP65-25C to +55C (-13F to +131F) 2004/108/EC EMC approval 2006/95/EC low voltage directive 0.25% of the measured range or 10 mm (0.39in) (whichever is greater) 0.25% of the measured range or 10 mm (0.39in) (whichever is greater) 10m (33ft) 0.3m (0.98ft) NB: Please refer to separate literature for db transducer performance if using an air application. OUTPUTS: Viper material: Analogue output: Serial output: Volt free contacts: Display: Radio Modem (optional): Maximum range: Communication bus (optional): PROGRAMMING: On-board programming: PC programming: Programming security: Programmed data integrity: SUPPLY: Power supply: Body in black Valox 357 with a 316 wiper blade and shaft 2 off Isolated output (to 150V) of 4-20 ma or 0-20 ma into 1kΩ (user programmable and adjustable) 0.1% resolution Half Duplex RS232 6 form "C" (SPDT) rated at 5A at 110V AC 192 x 128 pixel illuminated graphical display. Fully programmable display options. Integral keypad with menu navigation keys 4 20mA using wireless exempt frequencies 3km (1.86miles) line of site RS485 Modbus RTU/ASCII or Profibus DP V0 or V1 By integral keypad Via RS232 RJ11 port Via passcode (user selectable and adjustable) Non-volatile memory Universal 100-220VAC 50/60Hz DC 22-28V 14W maximum power (typically 11W) Fuse 2A slow blow 235 7 ENCLOSURE DIMENSIONS AND KNOCKOUT DETAILS DIN RAIL MOUNTING LUGS (OPTIONAL CLIPS REQ'D) 142 ALL DIMENSIONS IN mm 4 off 18mm DIA. (PG11) GLAND KNOCKOUTS 24.5 48 24.5 212 184 120 M16 M20 M20 M20 M20 M20 6 off GLAND KNOCKOUTS 27 28 28 28 30 Extract-Sludge Finder 2/6-13

Pulsar Process Measurement Ltd. Cardinal Building Enigma Commercial Centre Sandy's Road Malvern Worcestershire WR14 1JJ England Tel: +44 (0) 1684 891 371 Fax: +44 (0) 1684 575 985 Email: info@pulsar-pm.com Pulsar Process Measurement Inc. P.O. Box 5177 4565 Commercial Drive Suite 105 Niceville FL 32578 USA Tel: +1 850 279 4882 Fax: + 1 850 279 4886 Email: info.usa@pulsar-pm.com www.pulsar-pm.com Pulsar is a registered trademark of Pulsar Process Measurement Ltd. in the UK and USA. Pulsar operates a policy of constant development and improvement and reserves the right to amend technical details as necessary.