BlueSpin Cryo. (Cat. No. BSD-CRYO)

Similar documents
1580R User s Manual. Multi-Purpose, High Speed Centrifuge. Gyrozen Co., Ltd.

1236R User s Manual. Multi-Purpose, High Speed Centrifuge

624R User s Manual. Compact Bench-Top Refrigerated Centrifuge

Multi-Purpose, High Speed Centrifuge 1248R/1580R User s Manual

GLO GT416. Benchtop Centrifuge. User s Manual. Glotech Co., Ltd

Operation Manual Supra R22

Operating Manual Cellspin

CONTENTS. 3 MAINTENANCE 3.1 Service and Maintenance Maintenance and cleaning Glass breakage Disinfection

MICRO CENTRIFUGES. Experts in Laboratory Equipment

Large Capacity, High-Speed Centrifuge

OPERATION & MAINTENANCE MANUAL FOR SCEN-206 LED & MULTI-FUNCTION TYPE CENTRIFUGE PLEASE READ THIS MANUAL CAREFULLY BEFORE OPERATION.

Micro. Centrifuges.

XCM12 Mini-Centrifuge

DM0636 Multi-purpose Centrifuge

High Speed Micro-Centrifuge User manual

1248/R, 1236R, 1580/R

Instruction Manual. Labnet Spectrafuge 16M Microcentrifuge

Clinical, Low-Speed Centrifuge. Clinical, Low-Speed Centrifuge. Applications. 59 Order & Inquiry /

OPERATING MANUAL. Mega 17R HIGH SPEED REFRIGERATED CENTRIFUGE HANIL SCIENCE INDUSTRIAL CO., LTD. PRINTED IN KOREA

OPERATIONS MANUAL. Mini Centrifuge Model MCF Certified

Ultra 5.0 Manufactured By Hanil Science Industrial Co., Ltd. In Korea

INSTRUCTION MANUAL FOR BENCH TOP CENTRIFUGE Z 200 A

USER MANUAL. D2012 High Speed Mini Micro-Centrifuge SCILOGEX, LLC.

D3024 & D3024R High Speed (Refrigerated) Micro-Centrifuge DLAB Laboratory Instruments Limited

Rugged steel cabinet construction ensures quiet operation and long term reliability.

Instruction Manual for Table Top Refrigerated Centrifuge Z 36 HK

MIKRO R HETTICH DATA SHEET MICROLITRE CENTRIFUGES FASTER RESULTS IN MOLECULAR BIOLOGY FEATURES HIGHLIGHTS

USER MANUAL. D3024 & D3024R High Speed (Refrigerated) Micro-Centrifuge SCILOGEX, LLC.

INSTRUCTION MANUAL. CAT Place Table Top Centrifuge

Instruction Manual for Table Top Centrifuge Z 366

D2012 & D2012 plus High Speed Mini Centrifuge

Prism Microcentrifuge

Bio Lion Table Top Centrifuge XC-H165

Simple design with easy-to-use features

DM1424 Hematocrit Centrifuge

Large Capacity, High-Speed Centrifuge

1236R // 1248R LOW. capacity. HIGH G-Force High g-force 25,910 x g for fast centrifugation and efficient separation FAST HIGH

PrO-ASTM Centrifuges. Centurion. C1015 Micro Prime Centrifuge. A Micro that offers: Oil testing. Petroleum testing, ASTM methods

Instruction Manual for Microliter Centrifuge Z 233 M-2

air-cooled 18,000 rpm 25,356 xg 24,000 rpm 45,078 xg refrigerated Table-Top High-Speed Centrifuges High performance instrument for the daily routine

Model : LMHS-60 Please read this manual carefully before using the instrument Labnics Equipment

USER MANUAL PRF DUO. Clinical Centrifuge. Before using centrifuge, please carefully read this user manual for efficient operation and safety.

PrO-Ed Centrifuges. Centurion. C1015 Micro Prime Centrifuge. A Micro that offers: Education, Schools. C1015. (230V 50/60Hz). 1.C1015.

Instruction Manual for Microlitre Centrifuge Z 160 M

Supra R30. High Speed Centrifuges. High Speed Centrifuge. Supra R30 / Supra R22 / Supra R17 / Supra R12

Register your instrument! MiniSpin /MiniSpin plus. Operating manual

CENTRIFUGE USER MANUAL 642SYG V.1.0

Extremely quiet due to unique flexible drive system. Super High-Speed Centrifuge. Refrigerated - 30,000 rpm / 70,434 xg

Low Speed Centrifuge. Large capacity Swing out rotor takes 12 x 15mL Conical tubes, 4 x 100mL tubes or 20 vacu-tainers

Combi R515. Multi-purpose Centrifuges. Multi-purpose Centrifuge. Combi R515 / Combi 508

ROTANTA 46 RSC ROBOTIC Robotic Centrifuge cooled

Clinical Centrifuge. Before using centrifuge, please carefully read this user manual for efficient operation and safety.

REFRIGERATED CENTRIFUGE. LRF-A2 Series

Instruction Manual for the Z 216 MK Refrigerated Microcentrifuge

Packed with new features

Clinispin CT20 User Manual

Instruction Manual for Compact Centrifuge Z 206 A

Bio Lion Table Top Centrifuge XC-L5

Frontier 5000 Series

PrO-Cyto Centrifuges 61

Operating Manual. Multi Purpose Centrifuge Combi - 514R

Instruction Manual for the Revolutionary Science RS-102 RevSpin Microcentrifuge

Instruction Manual for the Revolutionary Science RS-200 RevSpin Microcentrifuge

Neofuge 13/13R. Laboratory Centrifuge. Applications. Heal Force leads you to healthier life

Contents. Introduction Inspection Notes on Safety Precautions. Chapter 1 Overview Product Overview Names of Parts 2

ROTINA 420/420 R Benchtop Centrifuges classic/cooled

EBA 21 Small Centrifuge

BLOOD BANK REFRIGERATED CENTRIFUGE

Thermo Scientific Heraeus Primo and Primo R Centrifuges. Flexible and efficient, compact high-performance centrifuges

Spectrafuge 24DMicrocentrifuge User Manual C2400 C V C V

Instruction Manual. Labnet Spectrafuge 7M Microcentrifuge

Model : LMHS-40 Please read this manual carefully before using the instrument Labnics Equipment

Instructions for Using Micro Plus Multiwell Plate Carriers

Z100A Clinical Centrifuge

INSTRUCTION MANUAL VISCOTESTER VT-05 / VT-06 PLEASE READ THIS MANUAL CAREFULLY BEFORE OPERATION

ScanFuge Centrifuges for IVF

REFRIGERATED CENTRIFUGE. LRF-A1 Series

ROTINA 380 /380R Benchtop Centrifuges classic/cooled

Thank you for purchasing the CHP Assembly Tool. In order to ensure maximum

INSTRUCTION MANUAL FOR THE CLINICAL 50 CENTRIFUGE

Universal Centrifuge 320/320R

MODEL 853VES. Model 853VES Operator s Manual. Laboratory Centrifuge IVD

EBA 21. Small Centrifuge

MIKRO 185 HETTICH DATA SHEET MICROLITRE CENTRIFUGE SMALL FOOTPRINT WITH UNMATCHED CAPACITY FEATURES HIGHLIGHTS

Operating Instructions ROTOFIX 32. Please enter the following details :: Stock no... Monitoring no... Location...

Multi-Purpose Rotor & Micro Rotor can be used in this convenient unit.

Thermo Scientific Heraeus Cryofuge 6000i and Cryofuge 8500i Centrifuge Series

Frontier TM Centrifuge FC5515 / FC5515R Instruction Manual

NANOPAC-300 & 500 Power Supply. Instruction manual NANOPAC-300 & NANOPAC-500

Lumitester PD-20 Control Kit

Thermo Scientific Heraeus Primo and Primo R Centrifuges. Flexible and efficient, compact high-performance centrifuges

materials and workmanship for 2 years. Should the centrifuge require warranty or Phone: or Fax:

Bench Centrifuge or Bench Centrifuge with Trolley

Immunity: EN capacity 75 µl Capillaries. 1,5 x 75 mm. Rotor and Lid as evaluation disc incl.

SPECTRAFUGE 6C. User Manual C0060 C V

EBA 21. Benchtop Centrifuge

MODEL 853VES Model 853VES Operator s Manual

Instruments Centrifugation

STANDARD OPERATING PROCEDURES SOP: 1002 PAGE: 1 of 5 REV: 0.0 DATE: 12/23/96

Centrifuge. Model XC-2000 Operating Manual

Transcription:

BlueLine Instruments for Electrophoresis INSTRUCTION MANUAL BlueSpin Cryo (Cat. No. BSD-CRYO) SERVA Electrophoresis GmbH - Carl-Benz-Str. 7 - D-69115 Heidelberg Phone +49-6221-138400, Fax +49-6221-1384010 e-mail: info@serva.de - http://www.serva.de

Index 1 Meanings of Symbols & Safety Precautions... 2 1.1 Symbols on the device... 2 1.2 Safety Precautions... 2 2 Packing List & Technical Specifications... 4 2.1 Packing List... 4 2.2 Technical Specifications... 4 3 Installation... 5 4 Operation... 8 4.1 Control panel... 8 4.2 Setting RPM / RCF... 9 4.2.1 Setting RPM... 9 4.2.2 Setting RCF... 9 4.3 Setting Time... 10 4.4 Setting Temperature and Fast Cool... 10 4.4.1 Setting Temperature... 10 4.4.2 Fast Cool... 11 4.5 Acceleration / Deceleration... 11 4.6 Program Saving & Recalling... 12 4.6.1 Saving... 12 4.6.2 Recalling... 12 4.7 Start/Stop... 12 4.8 Pulse... 13 4.9 Emergency Door Open... 13 4.10 Fuse replacement... 13 5 Maintenance... 14 5.1 Outer part of Instrument... 14 5.2 Chamber... 14 5.3 Shaft... 14 5.4 Rotor... 14 5.5 Transportation of Instrument... 14 6 Trouble Shooting... 15 6.1 Check List... 15 6.2 Error code... 16 7 Rotors and Accessories... 18 Vers. 04/13 1

1 Meanings of Symbols & Safety Precautions 1.1 Symbols on the device Symbol Meaning Symbol Meaning Indicate a hole for manual door opening in case of emergency Attention and warning for electric shock Attention and warning for rotor coupling. Attention and warning for door opening and closing Attention and warning for correct way of sample balancing in the rotor. 1.2 Safety Precautions Before using the instrument, please read this operation manual to ensure correct usage through understanding. Incorrect handling of the instrument could possibly result in personal injury or physical damage on the instrument or its accessories. ALWAYS locate the instrument on a flat, rigid and stable table capable of withstanding the weight of the instrument and its spinning operation. ALWAYS make a safety zone of 30 cm around the centrifuge to indicate that neither hazardous materials nor persons should be permitted within the area during operation. ALWAYS position the instrument with enough space on each side of instrument to ensure proper air circulation. ALWAYS install the instrument within a temperature and humidity controlled environment. (Permissible ambient temperature: +5 C ~ +35 C, Relative humidity: 85 %) Before connecting the power, check the rated voltage. 2

Unapproved rotors and associated accessories should not be used. Before operating the instrument, check if the rotor and the rotor lid are securely fastened. The instrument should be operated with a rotor properly installed and secured to the motor shaft. Mount the rotor on the motor shaft properly, check it with spinning manually. Do not stop the rotor by touching with hand during the instrument is running. Emergency door open should be performed only when spinning is completely stopped. The rated speed or specific gravity should not be exceeded. Samples whose density is greater than 1.2 g/ml must have reduced maximum rotational speed to avoid rotor failure. The sample content should not exceed 80 % of total capacity of a tube. Otherwise, it would cause spillage of sample fluid and even the tube breakage. ALWAYS load the tubes symmetrically with evenly weighted samples to avoid rotor imbalance. If necessary, use the water blank to counterbalance the unpaired sample. The operation speed should not exceed the highest value of the individual guaranteed g-forces of each centrifuge, rotor, bucket or adaptors and sample container, especially the guaranteed g-force of sample container should not be neglected. The rotors should be cleaned and kept dry after every use for longer life and safety. ALWAYS disconnect the power supply prior to maintenance care and service to avoid electrical shock. ALWAYS use proven disinfection procedures after centrifuging biohazardous materials. Flammable, toxic, radioactive, explosive, or corrosive materials should not be centrifuged. When it is necessary to use toxic or radioactive materials or pathogenic microorganisms which belong to the Risk Group II of WHO: Laboratory Bio- safety Manual, should follow national regulations. Attention Do not place dangerous materials within 30 cm distance around the instrument, and that is also recommended by IEC 61010-2-020. Use the emergency door open function only when the door button on the control panel is dumb under the condition of complete stop of rotor running. Never try to open or move the instrument if it is not completely stopped. If the power input is more than +/- 10% of the recommended voltage or fluctuates frequently, it may cause malfunction of the instrument and often result in serious damage. Install the instrument at a place without any kinds of corrosive gases. 3

2 Packing List & Technical Specifications 2.1 Packing List Microcentrifuge 6 mm Wrench Rotor Locking Tool Emergency Open Tool Power cord Manual 2.2 Technical Specifications Max. RPM / RCF 17,000 rpm / 27,237 xg Max. capacity 30 x 2.0 ml tubes 8 x 8-tube PCR strips Temp. range ( C) -20 ~ +40 FAST COOL button Time control RPM / RCF conversion Noise level Acc / Dec Yes Pulse, timed < 100 min or continuous Yes 56 db 9 / 10 steps Program memory 100 Rotor Identification Imbalance cutout Display Safety lid lock Power supply Power requirement Dimension (W x D x H) Weight without rotor Automation Yes Blue LCD Yes 220 V / 50~60 Hz 2 kva 310 mm x 620 mm x 265 mm 43 kg 4

3 Installation 1. Connect the AC Power cord to the power socket on the back of the instrument. 2. Turn on the instrument by pressing the switch on the back of the instrument. 3. For opening the door, press the [DOOR] button. 4. Close the door until hearing a clank shut. 5. When the door is opened, the door LED turns on. When the door is closed, the door LED turns off. If the door is opened, the instrument could not be operated even with pressing the [Start] button. For operational safety, this instrument has an automatic rotor recognition function. When you supply the power, the display shows "Searching Rotor" / Change to Rotor ID. If the rotor is absent, Error 9 will be displayed. This message will be cleared after rotor coupling and running. The door is not automatically opened after finishing operation to keep the sample at proper temperature. Power Failure: If there is any power failure during operation, the door can not be opened by using the [Door] button. The door can be opened only when the operation is completely stopped and the power is on again. If you want to open the door during the power failure, please refer to chapter: Emergency Door Open. 6. Before coupling a rotor, clean the motor shaft and chamber with soft dry towel. 5

7. Mount a proper rotor into the motor shaft. 8. Grasp the rotor with one hand, and place Rotor Locking Tool at the center hole of the rotor. To assemble the rotor: Rotate the Rotor Locking Tool clockwise until tightly assembled. To disassemble the rotor: Rotate the Rotor Locking Tool counterclockwise 9. To close the rotor lid, rotate the rotor lid nut clockwise. For opening lid: rotate the rotor lid nut counterclockwise. When you run a fixed angle rotor, make sure that the rotor lid is tightly closed. If you don t close the rotor lid completely, it will be crushed. 10. Positioning of sample tubes: Before loading sample tubes, check for water drops or dirt in the rotor hole or inner adaptor. If there is a water drop or dirt in the rotor hole or inner adaptor, remove it with soft dry cloth. Tubes should be placed in the rotor with same amount of samples at symmetrical positions. Only use appropriate centrifugal tubes and do not exceed the speed beyond the tube s max g-force. For safety, fill the sample for 70 ~ 80 % in the tubes. If the number of samples is not in pair, please load the control tubes at each symmetrical position. Otherwise, it results noise and vibration, and eventually damages the instrument. 6

Correct Ways of Sample Balancing & Tube usage: 7

4 Operation 4.1 Control panel Button RPM / RCF TIME Temp ACC / DEC PROG Fast Cool Pulse Enter Start/Stop Door Function For automatic conversion of RPM / RCF and to set the speed Use to set time, available range up to 99 min 59 sec (00:00: continuous) Use to set temperature (-20 C ~ 40 C) Use to set the acceleration & deceleration level from 1 to 9 steps. 0 in deceleration step means natural deceleration. Larger number means faster acceleration or deceleration. Use to save a set of setting values or recall the saved program number Use to reach rapid refrigeration up to the setting temperature. Use for quick runs Use for completion of data setting Use to start and stop operation Use to open instrument lid 8

4.2 Setting RPM / RCF 4.2.1 Setting RPM 1. Speed setting unit: 10 rpm or 100 rpm RPM MODE is generated by pressing the [RPM / RCF] button once. RPM LED is flickering on the display window. 2. Press the [ ] buttons to change input value. After 5 seconds from touching the [ ] buttons, the unit of setting value is changed from 10 rpm to 100 rpm. If you do not touch the [ ] button for 5 seconds, the setting mode is cleared. Touch the [Enter] button to save and complete the setting. 4.2.2 Setting RCF 1. Speed setting unit: 1 rcf or 10 rcf RCF MODE is generated by pressing the [RPM / RCF] button twice. RCF LED is flickering on the display window. 2. Press the [ ] buttons to change input value. After 5 seconds from touching the [ ] buttons, the unit of setting value is changed from 1 rcf to 10 rcf. If you do not touch the [ ] button for 5 seconds, the setting mode is cleared. Touch the [Enter] button to save and complete the setting. 9

4.3 Setting Time 1. Speed setting unit: 1 min or 10 min / 1 sec or 10 sec Time is down-counted after starting centrifugation. Press the [TIME] button once. MIN LED is flickering. 2. Press the [ ] buttons to change the minute value. After keeping holding finger on the [ ] buttons for 5 seconds, the unit of setting value is changed from 1 min to 10 min. If you do not touch the [ ] button for 5 seconds, the setting mode is cleared. 3. Press the [ENTER] button to pass the sec value setting. After keeping holding finger on the [ ] buttons for 5 seconds, the unit of setting value is changed from 1 sec to 10 sec. If you do not touch the [ ] button for 5 seconds, the setting mode is cleared. 4. Touch the [Enter] button to complete the setting. 4.4 Setting Temperature and Fast Cool 4.4.1 Setting Temperature 1. Temperature can be set from -20 C to 40 C Temp setting unit: 1 C Touch the [TEMP] button. Temperature value blinks on the display window. 2. Press the [ ] buttons to change input value. If you do not touch the [ ] button for 5 seconds, the setting mode is cleared. Touch the [Enter] button to save and complete the setting. 10

4.4.2 Fast Cool 1. Set the temperature as described in the chapter: Setting temperature 2. Touch the [Fast Cool] buttons for fast cooling. Fast Cool on LED is turned on. The display shows a message as follows: Searching Rotor >> recognition OK! By touching the [Fast Cool] button, the instrument is refrigerated down to the set temperature in a short time. During the fast cooling, the rotor runs at low speed (1,000 rpm). The passed time is showed on the display window. If you d like to load your sample tubes before pressing the [Fast Cool] button, please check if the sample is safe during spinning at 1,000 rpm. Before starting Fast Cooling, please check the rotor coupling and symmetry of sample tubes. 4.5 Acceleration / Deceleration 1. Touch [ACC / DEC] button. 2. Touch the [ ] buttons to change input ACC value. ACC blinks on the ACC / DEC display. Input the desired level of ACC from 1 to 9 (Level 9: The fastest acceleration). If you do not touch the [ ] button for 5 second, the setting mode is cleared. 3. Fix the ACC level by touching [Enter] button. 4. Touch the [ ] buttons to change input DEC value. DEC blinks on the ACC / DEC display. Input the desired level of DEC from 0 to 9 (Level 0: Natural deceleration / Level 9: The fastest deceleration). If you do not touch the [ ] button for 5 second, the setting mode is cleared. 5. Fix the DEC level by touching [Enter] button. 11

4.6 Program Saving & Recalling 4.6.1 Saving 1. Set parameters. 2. Touch the [PROG] button longer than 3 seconds. 3. Touch the [ ] buttons to change input Program number. If you do not touch the [ ] button for 5 second, the setting mode is cleared. Save up to 100 programs. (Program numbers from 00 to 99) 4. Touch the [Enter] button to complete the saving 4.6.2 Recalling 1. To recall the saved program, just touch the [PROG] button shortly (less than 1 sec). 2. Touch the [ ] buttons to select program number you want to recall and then touch the [Enter] button. If you do not touch the [ ] button for 5 second, the setting mode is cleared. When you touch the [Enter] button, display window shows the saved setting parameters (RPM / RCF, TIME, TEMP). 4.7 Start/Stop 1. After setting RPM / RCF, Time and Temp., press [Start / Stop] button. During running, a Start LED is turned on. The instrument is running only when the door is closed. By touching the [Start / Stop] button during centrifugation, the operation is stopped. 12

4.8 Pulse 1. If you press the [Pulse] button and release at the point you want to stop, the centrifuge decelerates immediately. 4.9 Emergency Door Open 1. The door can be unlocked manually using the Emergency Door Open Tool through the emergency opening hole. Find the emergency hole on the left side of the instrument. Insert the Emergency Door Open Tool into the hole and push it until the door is released. Manual opening should be performed only when spinning is completely stopped. Otherwise, harmful damage will be accompanied to not only operators but samples. After opening the door manually, it is recommended to wait until normal electricity comes back. 4.10 Fuse replacement 1. Replace the fuse only if the centrifuge is switched off and the power cord is disconnected from the device. You find the fuse case below the power outlet. Push with a flat-head screwdriver for bring out the fuse case. Replace the damaged fuse with new one from the fuse case and then re-connect the power. 13

5 Maintenance 5.1 Outer part of Instrument Clean the outside of the instrument with dry soft cloth. If necessary, dip the cloth in neutral detergent and clean contaminated area. Keep completely dry after cleaning. Do not use any volatile chemicals such as alcohol and benzene, etc. Be careful not to make scratches on the surface of the instrument. The scratches can cause corrosion on the surface of the instrument. If any rust appears, clean it with neutral detergents and keep dry. 5.2 Chamber Keep dry inside the chamber after every use. If the chamber is contaminated, dip the cloth in neutral detergent and clean contaminated area. 5.3 Shaft Always make special attention to clean the motor shaft to avoid any imbalance problem due to the contaminants. After using the instrument, take out the rotor from the shaft, and clean the shaft with dry soft cloth to keep dry. 5.4 Rotor If any parts are contaminated with samples, clean the rotor with soft wet cloth and keep the rotor dry. Be careful not to make scratches inside or on the surface of rotors. Any small scratches can cause corrosion of the rotor and big damage to the instrument. If you do not use the instrument, keep the rotor separately from the motor shaft and stand it upside down. 5.5 Transportation of Instrument If you need to move or ship the instrument, be cautious to protect the motor shaft from any physical impact or turbulence. Do not mount a rotor in any cases of movement. Fill inside the chamber with proper materials to keep the motor shaft on place and not to be influenced by physical pressure. 14

6 Trouble Shooting 6.1 Check List Symptom Check list Power failure Connect the AC Power cord and make sure that the line is completely connected between the instrument and power outlet. Check the power switch is turned on. Can t be started If the door is not closed completely, the instrument can t run. Check the Door LED on the display window and close the door completely. Can t open the door If the power is out, check the main fuse for the laboratory to supply the power. If it is not solved in shortly, open the door with spikes for safety of sample. Can t close the door Remove the dirt at the door latch and then close the door completely again. If the door seems not being closed by mechanical reason, please contact your distributor. Please check the balanced status of both the table and the instrument. Noise and vibration during running Please re-check the coupling status of the following three matches to minimize the noise 1. the balanced way of coupling of the rotor into the motor shaft 2. the completeness of fixing of the Rotor Locking Nut on the rotor 3. the matching status of Rotor Lid with the rotor Check balances of samples in the rotor. Load the same weight of samples symmetrically. 15

6.2 Error code If the instrument shows the error code with beeping sound, press [STOP] button to stop the beeping sound and press [Enter] button to release of the error status and make the instrument go to the default setting again. Error Possible Causes Actions Error 1 Error 2 Error 3 Error 4 Error5 Error 6 Error 7 Error 8 RPM Sensor Door Motor Overheating Low Voltage High Voltage Over Speed Software Imbalance Shut off the power supply, and then, turn on the power switch again to check the instrument. If the error code shows continuously although you try to operate again, please contact your distributor. The door is not closed completely. Remove the dirt at the door latch and then close the door completely again. Check the Door LED on the display window. If it is not solved in shortly, open the door with emergency door tool manually for safety of sample. The motor is overheated. Shut off the power supply for an hour, and then turn on the power switch for checking the instrument. If the error code shows continuously, please contact your distributor. The power input of Power supply (V / Hz) is 10 % less than required power. Shut off the power supply and then check the voltage of the Power supply (V / Hz). Use AVR to provide proper power. The power input of Power supply (V / Hz) is 10 % more than required power. Shut off the power supply and then check the voltage of the Power supply (V / Hz). Use AVR to provide proper power. The instrument is spun with over speed, due to problems in the overload of motor and the output of motor. Shut off the power supply, and then, turn on the power switch again to check the instrument. The installed software has bugs. Tuning the firmware (Download) Check weight-balances of samples. Turn off and on the instrument for checking. 16

Error 9 Error 11 Error 12 Error 15 Error 16 Rotor ID or RPM Sensor Chamber Temp. Error Temp. Sensor Error Motor Temp. Sensor Comp. Temp. Sensor If the function of rotor recognition is failed, this message is appeared. This message will be cleared by coupling an appropriate rotor. If the error code shows continuously, please contact your distributor. The instrument is not reached to setting temperature within an hour. No user action. Please contact your distributor. There is a faulty in the temperature sensing of chamber or over heated. No user action. Please contact your distributor. The motor temperature sensor can t recognize. No user action. Please contact your distributor. The temperature of compressor is over heated. No user action. Please contact your distributor. 17

7 Rotors and Accessories Product A Fixed Angle Microtube Rotor with aluminum lid for 24 microtubes A Fixed Angle Microtube Rotor with aluminum lid for 30 microtubes Cat. No. BS-MRR24 BS-MRR30 A Fixed Angle PCR-tube Rotor for 8 rows of PCR strips, no lid BS-MRP64 0.2 ml Adaptor of microtube rotors BS-A02 0.5 ml Adaptor of microtube rotors BS-A05 18

EC-Declaration of Conformity We hereby certify that the following described machine in it s conception, construction and form is in accordance with all the relevant essential health and safety requirements of the EC EMC Directive 2004/108/EC (21 st May 2007) and the EC Low Voltage Directivee 2006/95/EC (12 th December 2006) is adopting these directives. This declaration is no longer valid if the machine is modified without our consent. Authorized representative: SERVA Electrophoresis GmbH Carl-Benz-Str. 7 D-69115 Heidelberg Tel: +49-6221-13840-0 Description of the machine: Function: Centrifuge Type/modell : BlueSpin Cryo The agreement with further explained: EN 61010-1:2001: Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 1: General requirements EN 61010-2-020:2006: Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 2-020: Particula requirements for laboratory centrifuges EN 61326-1:2006: Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 1: General requirements EN 55011:2007: Industrial, scientific and medical (ISM) radio-frequency equipment - Electromagnetic disturbance characteristics - Limits and methods of measurement Authorized person for the technical documentation: Dr. Marc Seidler SERVA Electrophoresis GmbH Carl-Benz-Str. 7 D-69115 Heidelberg valid guidelines/regulations following for the product is Heidelberg, 23.04.13 Dr. Marc Seidler, CE official 19

Headquarters SERVA Electrophoresis GmbH Carl-Benz-Str. 7 D-69115 Heidelberg Germany SERVA Electrophoresis GmbH Pinnauallee 4 D-25436 Uetersen Germany E-Mail: info@serva.de Internet: www.serva.de German Customers To place orders Phone: 06221 13840-0 Fax: 06221 13840-10 Customer Care Phone: 06221 13840-46 Fax: 06221 13840-10 Technical Service Phone: 06221 13840-44 Fax: 06221 13840-54 E-Mail: tech.service@serva.de Technical Service Collagenase Phone: 04122 712-413 Fax: 04122 712-286 Free Phone: 0800 737 8246 Free Fax: 0800 737 8247 International Customers To place orders Please contact your local Distributor (please visit www.serva.de) Customer Care Phone: +49 6221 13840-47 Fax: +49 6221 13840-10 Technical Service Phone: +49 6221 13840-44 Fax: +49 6221 13840-54 E-Mail: tech.service@serva.de Technical Service Collagenase Phone: +49 4122 712-413 Fax: +49 4122 712-286 Free Phone: 00800 737 82462 (within Europe, only)